This is a pre-solicitation notice for a firm fixed price contract to provide inspection, testing, maintenance and repair services for backflow preventers installed at various U.S. Army installations in Italy. The performance locations include facilities in Vicenza, Caserma Ederle, Caserma Del Din, Villaggio della Pace, Longare, ASP #7, Lerino and Torri Di Quartesolo. Interested vendors must submit capability statements by April 9, 2021 demonstrating qualifications to perform the services, along with valid Chamber of Commerce registration, SAM registration including DUNS and NATO codes. A pre-proposal conference will be held in May-June 2021. The base contract term is one year with four one-year options that are not guaranteed to be exercised. The contract will be awarded after release of a request for quotation with award method and other solicitation details provided at that time.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX C

EXISTING BACKFLOW PREVENTION DEVICES

INVENTORY CASERMA EDERLE VICENZA

ITEM#

BLDG N°

BLDG NAME

TYPE OF BLDG

US ARMY FACILITY

CLASSIFICATION/HAZARD

CLASSIFICATION

RECOMMENDED DEVICE / REPAIRS / MODIFICATIONS

SIZE

(INCHES)

MANUFACTURER

SERIAL N.

SYSTEM TYPE

CROSS

CONNECTION

HAZARD LEVEL

QTY

LOCATION

TEST

FREQUENCY

REMARKS/COMMENTS

9A

ENLISTED UPH

BARRACKS

CLASS 1/LOW

INSTALL A NEW SHUT‐OFF VALVES (V1 AND V2)

DN 80

CALEFFI

WATER MAIN

HEALTH

MECH. ROOM

ANNUAL

INSTALL RPZ ON HEAT

AND CHILL MAKE UP

9A

DN 15

115179

HEAT MAKE UP

9B

8A

INSTALL A NEW SHUT‐OFF VALVE (V1)

DN 65

8A

DN 25

124124

8B

8B

103115

7A

7A

NOT CONTROLLABLE

DN 20

REPLACE WITH RPZ

CALEFFI MOD. BA

7B

7B

96760

6B

6B

117688

6A

6A

105177

5A

5A

123995

5B

5B

103117

4B

CO HQ BLDG, POLICE/MP

STA,

ADMIN. OFFICES

124126

INSTALL RPZ ON

DOMESTIC WATER

4A

CO HQ BLDG, 1+1

BILLETS, DFAC CARAB.

DN 40

41245

4A

CO HQ BLDG, 1+1

BILLETS, DFAC CARAB.

SETAF, ADMIN GEN PURP

DENTAL CLINIC

CLASS 3/HIGH

123554

SEMI‐

ANNUAL

SETAF HQ BLDG

117683

118173

80A

HQ CO BLDG

EXTERNAL

BOX

80B

80C

123994

HEATING PLNT BUILDING

BOILER PLANT

WATER MAIN 1

HEATING PLNT BUILDING

BOILER PLANT

WATER MAIN 2

DN 100

INSTALL A NEW SHUT‐OFF VALVES (V1 AND V2),

SOLDIERS THEATRE

PUBLIC FACILITIES

DN 32

123849

SOLDIERS THEATRE

124015

CHILL MAKE UP

MAKE UP

63A

509TH SIGNAL

BATTALION

123998

63B

103556

63B

124148

AFN

WAREHOUSE

LOW TO HIGH

NOT CONTROLLABLE ( WORKS IN PROGRESS)

DN 50

38425

114205

HEAT/CHILL

ANNUAL

DII‐TCF

124123

BN HQ BLDG

74997

BN HQ BLDG

ADMIN GEN. PURP

CHAPEL

CHAPEL

BATHROOMS

ANNUAL

VEH‐MAINT SHOP

SCIF

124125

SCIF

124014

SEWER LIFT STATION

WASTERWATER PLUMB.

WATTS

BUILDING

25445

INSTALL A NEW SHUT‐OFF VALVES (V2)

35593

COMMISSARY

INSTALL A NEW SHUT‐OFF VALVES (V1 )

35590

SOFTENER

COMMISSARY

117918

103124

MNT GEN PURPOSE

MNT GEN PURPOSE

DOL HQ BLDG

124128

DPW OFFICES

103545

TRADE SHOP

122712

ANNUAL

BATHROOM

74 18 NAVFAC ADMIN. OFFICES CLASS 1/LOW DN 32 CALEFFI 70186 WATER MAIN HEALTH 1 BUILDING ANNUAL

5TH MAINT.COMPANY

CALIBRATION LAB

HONEYWELL

5TH MAINT.COMPANY

CALIBRATION LAB

117680

123863

WORKSHOP

24344

WORKSHOP

79 50 FIRE DEPARTMENT FIRE DEPARTMENT CLASS 1/LOW DN 40 CALEFFI 32348 WATER MAIN HEALTH 1 GARAGE ANNUAL

FLAMMABLE MAT.

STORAGE

FLAMMABLE MAT.

STORAGE

16621

SPRINKLER

ROOM

AUTO SKILL DEV CTR

VEHICLE WASHING FAC

113695

FIRE DEPARTMENT

WASH RACK

WASH RACK

INSTALL VALVE V2 ON DOMESTIC WATER

39435

ROOM WASH

AUTO SKILL DEV CTR

VEHICLE WASHING FAC

35614

INSTALL A NEW SHUT‐OFF VALVES (V1 )

103519

ORG STR BLDG

503RD BN HQ BLDG

117794

117713

BRIGADE HQ BLDG

INSTALL VALVE V2

32248

ACS CTR

DINING FACILITY

35592

ACS CTR

123571

123861

35566

41074

117686

CHILD DEV CENTER

CHILD CARE FAC

123997

102992

BOWLING ALLEY

124017

39716

INSTALL A NEW SHUT‐OFF VALVES (V1 AND V2) ,

123553

SWIMMING POOL

123999

122853

ANNUAL

ANNUAL

103544

103122

GYM

GYMNASIUM

35610

24755

AUTO AID INST

AUTO AID INST

AAFES ADMIN‐MWR TAX

RELIEF

41247

113693

117685

GOLDEN LION CLUB

CLUBS‐BEVERAGE‐BARS

INSTALL VALVE V2

,INSTALL RPZ ON HEAT

GOLDEN LION CLUB

CLUBS‐BEVERAGE‐BARS

107961

BURGER KING

113694

94955

103089

REC. EQ CHECKOUT

RECREATION

INSTALL A NEW SHUT‐OFF VALVES (V1)

103086

REC. EQ CHECKOUT

CLUB VENETO

41076

CLUB VENETO

122711

ARTS E CRAFT

ARTS E CRAFT

SCHOOL

SEMI‐

ANNUAL

SEMI‐

ANNUAL

SEMI‐

ANNUAL

SEMI‐

ANNUAL

25580

ANNUAL

INDOOR FIRING RANGE

BATHROOMS

INSTALL A NEW SHUT‐OFF VALVES (V2) ,

103543

EDERLE INN

GUEST HOUSES

15240

ANNUAL

122693

ANNUAL

KINDERGARTEN

KINDERGARTEN

INSTALL A NEW SHUT‐OFF VALVES (V1 AND V2) ,

41244

PX‐COMMISSARY

123549

AUDITORIUM‐CINEMA

24756

AUDITORIUM‐CINEMA

DOMESTIC WATER,

REPLACE BY PASS RPZ

LAUNDRY‐SERV. CENTER

LAUNDRIES

MED TO HIGH

INSTALL A NEW VALVE V1‐V2

35611

SOFTENER

ADMIN‐EXCH. BRANCH

BOX

103087

YOUTH CENTER

118171

105604

122715

25579

124127

32249

105165

122710

25577

INVENTORY DEL DIN VICENZA

POST OFFICE BRANCH

MECH.

120493

122714

ADMIN ORG BLDG

NON ORG PK MLTVC

27022

BANK‐GEN ADMIN.PURP

BANK‐GEN ADMIN.PURP

107960

EXCHANGE BRANCH

105606

27024

121999

ROOM

ROOM

DN 150

FA433808

103736

103735

DN 150

EN12729

115923

114837

PHYS FITNESS CTR‐

INDOOR POOL

POOL

NOT HEALTH

ROOM

PHYS FITNESS CTR‐

INDOOR POOL

POOL

116466

ROOM

RECREATION CTR BANK

ROOM

RECREATION CTR BANK

101349

ROOM

CO HQ BLDG

204967

122692

AC/HEAT PLT.

ELECT/POWER/GAS

ELECT/POWER/GAS

ROOM

ELECT/POWER/GAS

ELECT/POWER/GAS

ROOM

COMMO CENTER CABLE

VAULT

123569

116467

FIRE STATION

ROOM

FIRE STATION

116469

ROOM

204676

117021

41075

109035

41071

113706

60433

122713

PETROLEUM OIL

LUBRIFICANTS POL

PETROLEUM OIL

LUBRIFICANTS POL

HAZ MAT STR INS

VEHICLE SCALES

HAZ MAT STR INS VEHICLE

SCALES

INSIDE

TNG AIDS CTR INDOOR

FIR RG

TNG AIDS CTR INDOOR FIR

RG

TNG AIDS CTR INDOOR

FIR RG

TNG AIDS CTR INDOOR FIR

RG

109037

ORG STR BLDG PARK

PAVED

ORG STR BLDG PARK

PAVED

28343

VEHICLE SEARCH OFFICE

VEHICLE SEARCH OFFICE

41246

VISITOR'S CENTER

36834

36838

123570

BDE HQ BLDG

116465

BDE HQ BLDG

INVENTORY LONGARE VICENZA

11101

TT ENL BARRACKS

11101

TT ENL BARRACKS

11102

VET FACILITY

SEMI‐ANNUAL

11102

11103

PHYS FIT CTR

11103

7 11126 ORG STR BLDG ADMIN. OFFICES CLASS 1/LOW DN 15 CALEFFI 122856 HEAT MAKE UP HEALTH 1 MECH. ROOM ANNUAL

11126

DOMESTIC WATER

9 11110 EMERG OPNS CNTR ADMIN. OFFICES CLASS 1/LOW DN 15 WATTS 26810 HEAT MAKE UP HEALTH 1 MECH. ROOM ANNUAL

10 11110 EMERG OPNS CNTR ADMIN. OFFICES CLASS 1/LOW DN 25 CALEFFI 119273 WATER MAIN HEALTH 1 MECH. ROOM ANNUAL

11 11107 USAR CENTER ADMIN. OFFICES CLASS 1/LOW DN 15 CALEFFI 122852 HEAT MAKE UP HEALTH 1 MECH. ROOM ANNUAL

11107

USAR CENTER

11108

USAR CENTER

11109

INVENTORY VILLAGGIO AMERICANI VICENZA

TEST FREQUENCY

REC SPT FAC

122854

DEF. 1

35914

35925

36063

DEF. 2

POTABLE WATER

POTABLE WATER

SEMI ‐ANNUAL

CYSS

CDC UNDER 6 YRS

123845

DEF. 3

INSTALL A NEW SHUT‐OFF VALVES (V1‐V2)

DEF. 4

BRANDONI

AC/HEAT PLT BLDG

34863

118710

DEF. 5

GATE

GATE

103734

INVENTORY OF NEW BACKFLOW PREVNTION DEVICES

EDERLE

BLDG 12 MECHANICAL ROOM

BLDG 300 ICE MACHINE

BLDG.112 – MECHANICAL

ROOM NEW WING,

QUANTITY 2, DN25

DEL DIN

BLDG 34 MECHANICAL ROOM

DD035 FOUNTAIN

DD048 FOUNTAIN

DD050 FOUNTAIN

ASP#7

BLDG 1 MECHANICAL ROOM

BLDG 9 MECHANICAL ROOM

BLDG 13 MECHANICAL ROOM

LONGARE

BLDG 2 BOILER ROOM

INVENTORY CASERMA EDERLE VICENZA
INVENTORY VILLAGGIO AMERICANI VICENZA