Circuit Listing Notes:
1. Circuits listed in this report contain leading zeros to maintain proper sorting. These leading zeros are not incorporated into the circuit number on other documentation. (Example: “C0015” is referred to as “C15”)
2. Circuit routings include raceways from main electrical vaults (manholes) to destination devices. Cables inside the vaults shall be installed on cable trays. For clarity, cable tray is not specified herein.
3. For Cable types, see “Conductor Type Key” on sheet 2 of this document.
4. Circuits and routing for lighting panel branch circuits are generally not included in this document. These circuits shall be installed as indicated on the drawings.
6/27/2019 12:09:24 PM Page 1 of 6
Lock and Dam 24, Clarksville, Mo.
Circuit Listing
(Fiber Optic Cable Retermination)
JULY 2019
Letter Description
A Control Cable, Multi-Conductor, Type TC, 600V, with moisture barrier. ICEA Method 1, Option A Color Code (no W or G wires).
B Control Cable, Multi-Conductor, Type TC, 600V, with moisture barrier. ICEA Method 1, Option B Color Code (has W wire).
C Power Cable, Multi-Conductor, Type TC, 600V, with moisture barrier, #12 thru #4/0 AWG.
D Power Cable, Single Conductor, Type TC, 600V, with moisture barrier.
E Control Cable, Multi-Conductor, Type TC, 600V. ICEA Method 1, Option A Color Code (no W or G wires). THHN/THWN with PVC jacket.
F Control Cable, Multi-Conductor, 600V. ICEA Method 1, Option B Color Code (has W wire).
G Power Cable, Single Conductor, THHN/THWN 600V.
H Fiber Optic Cable, 62.5/125, Multimode, Glass, Breakout Type.
J Twisted Pair Shielded Instrumentation Cable.
K Lighting Panel Circuit.
L Control Cable, Multi-Conductor, THHW/THWN, 600V, with extra-flexible stranding. ICEA Method 1, Option B Color Code (has W wire).
M Ethernet Cable
N Communication cable as required by interconnecting equipment manufacturers.
P Power Cable, Multi-Conductor, 600V, Flexible Hard Service Cord, #18 thru
#2 AWG.
Q Control Cable, 3 Cond. #14AWG, Seacoast #LSTSGU-4 (.449 DIA), COMM.
MARINE
R Control cable, 12 Cond. #14 COASTAL # MSDT-12 (.61 DIA.), COMM.
MARINE
S Power Cable, 4 Cond. #4 AWG, COASTAL #F41 (.97 DIA.) COMM.
MARINE
T Encoder Cable, Baldor # CBL091ZD-2, COMM.
U Power Cable, Multi-Conductor, Type TC
Conductor Type Key
Page 2 of 6Lock and Dam 24 Circuit Listing -- (Fiber Optic Cable Retermination)
Circuit Dwg No.
Conductor Volt Type
Function Origin Destination
System
Lock and Dam 24 Circuit Listing -- (Fiber Optic Cable Retermination) 6/27/2019 12:09:25 PM Page 3 of 6
Final Installation Raceways
Notes C0251 E-90, 91
12 FIBER CABLE N/A
H
IPC NETWORK TO LOWER
LAND WALL CONTROL BOOTH
LAN (CENTRAL CONTROL
CONSOLE)
IPC1 (CB-1) (INDUSTRIAL
PERSONAL COMPUTER)
(CONTROL BOOTH)
R991, R2117, R2147, R2177, R2195
IPC REPLACES ORIGINAL 6-FIBER CABLE
C0252 E-90, 91
12 FIBER CABLE N/A
H
IPC NETWORK TO UPPER
LAND WALL CONTROL BOOTH
LAN (CENTRAL CONTROL
CONSOLE)
IPC2 (CB-2) (INDUSTRIAL
PERSONAL COMPUTER)
(CONTROL BOOTH)
R991, R2217, R2247, R2277, R2295
IPC REPLACES ORIGINAL 6-FIBER CABLE
C0260 E-91
12 FIBER CABLE N/A
H
PLC NETWORK TO RRMG-1 MCC3-PLC REMOTE RACK-MG-1 R158, R2117, R2147, R2177
MG1 REPLACES ORIGINAL 6-FIBER CABLE
C0261 E-91
12 FIBER CABLE N/A
H
PLC NETWORK TO RRMG-2 REMOTE RACK-MG-1 REMOTE RACK-MG-2 R158, R269, R2117, R2147, R2177, R2217, R2247, R2277
MG2 REPLACES ORIGINAL 6-FIBER CABLE
C0262 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO RRMG-3 REMOTE RACK-MG-2 REMOTE RACK-MG-3 R269, R381, R629, R2217,
R2247, R2277, R2307, R2367
MG3
C0263 E-91
12 FIBER CABLE N/A
H
PLC NETWORK TO RRMG-4 REMOTE RACK-MG-3 REMOTE RACK-MG-4 R381, R433, R2307, R2367, R2421, R2456, R2476, R2496
MG4 REPLACES ORIGINAL 6-FIBER CABLE
C0265 E-91
6 FIBER CABLE N/A
H
PLC NETWORK RR-MCC3 TO
RRMG-1
MCC3-PLC RR-MG1 R158, R2117, R2147, R2177
MG1 REPLACED BY 12-FIBER C0260
C0266 E-91
6 FIBER CABLE N/A
H
PLC NETWORK RRMG-1 TO
RRMG-2
REMOTE RACK-MG-1 REMOTE RACK-MG2 R158, R269, R2117, R2147,
R2177, R2217, R2247, R2277
MG2 REPLACED BY 12-FIBER C0261
C0267 E-91
6 FIBER CABLE N/A
H
PLC NETWORK RRMG-2 TO
RRMG-3
REMOTE RACK-MG-2 REMOTE RACK-MG3 R269, R381, R629, R2217,
R2247, R2277, R2307, R2367
MG3
C0268 E-91
6 FIBER CABLE N/A
H
PLC NETWORK RRMG-3 TO
RRMG-4
REMOTE RACK-MG-3 REMOTE RACK-MG4 R381, R433, R2307, R2367,
R2421, R2456, R2476, R2496
MG4 REPLACED BY 12-FIBER C0263
Conductor Volt Type
Function Origin Destination
System
Lock and Dam 24 Circuit Listing -- (Fiber Optic Cable Retermination) 6/27/2019 12:09:25 PM Page 4 of 6
Final Installation Raceways
Notes C1162 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACKS RR-TG1
THRU RR-TG8
MCC1-PLC REMOTE RACK-TG1 R629, R713, R1006, R1021,
R1826, R2432
TG1
C1163 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG2
REMOTE RACK-TG1 REMOTE RACK-TG2 R1021, R1046, R1061
TG2
C1164 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG3
REMOTE RACK-TG2 REMOTE RACK-TG3 R1061, R1086, R1101
TG3
C1165 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG4
REMOTE RACK-TG3 REMOTE RACK-TG4 R1101, R1126, R1141
TG4
C1166 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG5
REMOTE RACK-TG4 REMOTE RACK-TG5 R1141, R1166, R1181
TG5
C1167 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG6
REMOTE RACK-TG5 REMOTE RACK-TG6 R1181, R1206, R1221
TG6
C1168 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG7
REMOTE RACK-TG6 REMOTE RACK-TG7 R1221, R1246, R1261
TG7
C1169 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG8
REMOTE RACK-TG7 REMOTE RACK-TG8 R1261, R1286, R1301
TG8
C1170 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACKS RR-TG1
THRU RR-TG8
MCC1-PLC REMOTE RACK-TG1 R629, R713, R1006, R1021,
R1826, R2432
TG1
C1171 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG2
REMOTE RACK-TG1 REMOTE RACK-TG2 R1021, R1046, R1061
TG2
Conductor Volt Type
Function Origin Destination
System
Lock and Dam 24 Circuit Listing -- (Fiber Optic Cable Retermination) 6/27/2019 12:09:25 PM Page 5 of 6
Final Installation Raceways
Notes C1172 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG3
REMOTE RACK-TG2 REMOTE RACK-TG3 R1061, R1086, R1101
TG3
C1173 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG4
REMOTE RACK-TG3 REMOTE RACK-TG4 R1101, R1126, R1141
TG4
C1174 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG5
REMOTE RACK-TG4 REMOTE RACK-TG5 R1141, R1166, R1181
TG5
C1175 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG6
REMOTE RACK-TG5 REMOTE RACK-TG6 R1181, R1206, R1221
TG6
C1176 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG7
REMOTE RACK-TG6 REMOTE RACK-TG7 R1221, R1246, R1261
TG7
C1177 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG8
REMOTE RACK-TG7 REMOTE RACK-TG8 R1261, R1286, R1301
TG8
C1178 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG 9
REMOTE RACK-TG-8 REMOTE RACK-TG9 R1301, R1326, R1341
TG9
C1179 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG10
REMOTE RACK-TG9 REMOTE RACK-TG10 R1341, R1366, R1381
TG10
C1180 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG11
REMOTE RACK-TG10 REMOTE RACK-TG11 R1381, R1406, R1421
TG11
C1181 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG12
REMOTE RACK-TG11 REMOTE RACK-TG12 R1421, R1446, R1461
TG12
Conductor Volt Type
Function Origin Destination
System
Lock and Dam 24 Circuit Listing -- (Fiber Optic Cable Retermination) 6/27/2019 12:09:25 PM Page 6 of 6
Final Installation Raceways
Notes C1182 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG13
REMOTE RACK-TG12 REMOTE RACK-TG13 R1461, R1486, R1501
TG13
C1183 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG14
REMOTE RACK-TG13 REMOTE RACK-TG14 R1501, R1526, R1541
TG14
C1184 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG15
REMOTE RACK-TG14 REMOTE RACK-TG15 R1541, R1566, R1581
TG15
C1190 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG 9
REMOTE RACK-TG-8 REMOTE RACK-TG9 R1301, R1326, R1341
TG9
C1191 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG10
REMOTE RACK-TG9 REMOTE RACK-TG10 R1341, R1366, R1381
TG10
C1192 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG11
REMOTE RACK-TG10 REMOTE RACK-TG11 R1381, R1406, R1421
TG11
C1193 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG12
REMOTE RACK-TG11 REMOTE RACK-TG12 R1421, R1446, R1461
TG12
C1194 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG13
REMOTE RACK-TG12 REMOTE RACK-TG13 R1461, R1486, R1501
TG13
C1195 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG14
REMOTE RACK-TG13 REMOTE RACK-TG14 R1501, R1526, R1541
TG14
C1196 E-91
6 FIBER CABLE N/A
H
PLC NETWORK TO DAM
REMOTE RACK RR-TG15
REMOTE RACK-TG14 REMOTE RACK-TG15 R1541, R1566, R1581
TG15