Text version

PUERTO RICO AIR NATIONAL GUARD – 156TH WING 02 JUNE 2017 15 JAN 2018

RESERVE FORCES BUILDING #16 RENOVATION ADDENDUM 001

MUNIZ AIR NATIONAL GUARD BASE – CAROLINA, PR FINAL B-3 SUBMITTAL

VISUAL DISPLAY UNITS 10 11 00 - 1

SECTION 10 11 00 - VISUAL DISPLAY UNITS

PART 1 - GENERAL

1.1 SUMMARY

A. Section Includes:

1. Visual display board assemblies.

1.2 PREINSTALLATION MEETINGS

A. Preinstallation Conference: Conduct conference at Project site.

1.3 ACTION SUBMITTALS

A. Product Data: For each type of product.

1. Include construction details, material descriptions, dimensions of individual components and profiles, finishes, and accessories for visual display units.

B. LEED Submittals:

1. Product Data for Credit MR 4: For products having recycled content, documentation indicating percentages by weight of postconsumer and preconsumer recycled content.

Include statement indicating cost for each product having recycled content.

2. Product Data for Credit MR 5: For products harvested or manufactured within a 500-mile radius of the project site, and distances from these locations to the project site. Include statement indicating cost for each product documented.

3. Product Data for Credit MR 6: For products containing rapidly renewable materials, documentation indicating percentages by weight of rapidly renewable content. Include statement indicating cost for each product documented.

4. Product data from manufacturers indicating VOC content of any adhesives, sealants, paints, or coatings used documenting compliance with EQ Credit 4.1 and 4.2.

C. Shop Drawings: For visual display units.

1. Show locations of panel joints.

2. Show locations and layout of special-purpose graphics.

3. Include sections of typical trim members.

D. Samples for Verification: For each type of visual display unit indicated.

1. Visual Display Panel: Not less than 8-1/2 by 11 inches, with facing, core, and backing indicated for final Work. Include one panel for each type, color, and texture required.

2. Trim: 6-inch- long sections of each trim profile.

VISUAL DISPLAY UNITS 10 11 00 - 2

3. Accessories: Full-size Sample of each type of accessory.

E. Product Schedule: For visual display units.

1.4 INFORMATIONAL SUBMITTALS

A. Qualification Data: For qualified Installer.

B. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for surface-burning characteristics of tackboards.

C. Sample Warranties: For special warranties.

1.5 CLOSEOUT SUBMITTALS

A. Maintenance Data: For visual display units to include in maintenance manuals.

1.6 QUALITY ASSURANCE

A. Installer Qualifications: An entity that employs installers and supervisors who are trained and approved by manufacturer.

1.7 DELIVERY, STORAGE, AND HANDLING

A. Deliver factory-fabricated visual display units completely assembled in one piece. If dimensions exceed maximum manufactured unit size, or if unit size is impracticable to ship in one piece, provide two or more pieces with joints in locations indicated on approved Shop Drawings.

1.8 PROJECT CONDITIONS

A. Environmental Limitations: Do not deliver or install visual display units until spaces are enclosed and weathertight, wet-work in spaces is complete and dry, work above ceilings is complete, and temporary HVAC system is operating and maintaining ambient temperature and humidity conditions at occupancy levels during the remainder of the construction period.

B. Field Measurements: Verify actual dimensions of construction contiguous with visual display units by field measurements before fabrication.

1. Allow for trimming and fitting where taking field measurements before fabrication might delay the Work.

VISUAL DISPLAY UNITS 10 11 00 - 3

1.9 WARRANTY

A. Special Warranty for Porcelain-Enamel Face Sheets: Manufacturer agrees to repair or replace porcelain-enamel face sheets that fail in materials or workmanship within specified warranty period.

1. Failures include, but are not limited to, the following:

a. Surfaces lose original writing and erasing qualities.

b. Surfaces exhibit crazing, cracking, or flaking.

2. Warranty Period: 15 years from date of Substantial Completion.

PART 2 - PRODUCTS

2.1 MANUFACTURERS

A. Source Limitations: Obtain each type of visual display unit from single source from single manufacturer.

2.2 PERFORMANCE REQUIREMENTS

A. Surface-Burning Characteristics: Comply with ASTM E 84; testing by a qualified testing agency. Identify products with appropriate markings of applicable testing agency.

1. Flame-Spread Index: 25 or less.

2. Smoke-Developed Index: 50 or less.

2.3 VISUAL DISPLAY BOARD ASSEMBLY

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

1. Best-Rite; MooreCo, Inc.

2. Claridge Products and Equipment, Inc.

3. Egan Visual Inc.

4. Marsh Industries, Inc.

5. Newline Products, Inc.

B. Visual Display Board Assembly: Factory fabricated.

1. Assembly: markerboard and tackboard.

2. Corners: Square.

3. Width: As indicated on Drawings. As Scheduled.

4. Height: As indicated on Drawings. As Scheduled.

5. Mounting Method: Direct to wall.

VISUAL DISPLAY UNITS 10 11 00 - 4

C. Markerboard Panel: Porcelain-enamel-faced markerboard panel on core indicated.

1. Color: White.

D. Tackboard Panel: Natural-cork tackboard panel on core indicated.

1. Fabric Wrapped Edge: Wrap edge of tackboard panel with fabric facing.

2. Color and Pattern: As selected by Architect from full range of industry colors.

E. Aluminum Frames and Trim: Fabricated from not less than 0.062-inch- thick, extruded aluminum; standard size and shape.

1. Field-Applied Trim: Manufacturer's standard, snap-on trim with no visible screws or exposed joints.

2. Aluminum Finish: Clear anodic finish.

a. Color: As selected by Architect from full range of industry colors and color densities.

F. Joints: Make joints only where total length exceeds maximum manufactured length. Fabricate with minimum number of joints, as indicated on approved Shop Drawings.

G. Combination Assemblies: Provide manufacturer's standard exposed trim between abutting sections of visual display panels.

H. Chalktray: Manufacturer's standard; continuous.

1. Solid Type: Extruded aluminum with ribbed section and smoothly curved exposed ends.

I. Display Rail: Manufacturer's standard, extruded-aluminum display rail with plastic-impregnated-cork insert, end stops, and continuous paper holder, designed to hold accessories.

1. Size: 2 inches high by full length of visual display unit.

2. Map Hooks and Clips: Two map hooks with flexible metal clips for every 48 inches of display rail or fraction thereof.

3. Tackboard Insert Color: As selected by Architect from full range of industry colors.

4. Aluminum Color: Match finish of visual display assembly trim.

J. Paper Holder Display Rail: Extruded aluminum; designed to hold paper by clamping action.

K. Markerboard Panel Schedule: Room, Location, and Size (Height x Width):

1. MEDICAL READINESS 104 North Partition 4’-0”H x 4’-0”W

2. NURSING SERVICES 141 North Partition 4’-0”H x 4’-0”W

3. CLINIC ADMIN 150 South Partition 4’-0”H x 4’-0”W

4. MULTIPURPOSE/DINING 157 West Partition 4’-0”H x 10’-0”W

5. FSS 171 North Partition 4’-0”H x 4’-0”W

VISUAL DISPLAY UNITS 10 11 00 - 5

L. Tackboard Panel Schedule: Room, Location, and Size (Height x Width):

1. LOUNGE 139 South Partition 4’-0”H x 4’-0”W

2. NURSING SERVICES 141 North Partition 4’-0”H x 4’-0”W

3. FSS 171 North Partition 4’-0”H x 4’-0”W

2.4 GENERAL FINISH REQUIREMENTS

A. Comply with NAAMM's "Metal Finishes Manual for Architectural and Metal Products" for recommendations for applying and designating finishes.

B. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

C. Appearance of Finished Work: Noticeable variations in same piece are unacceptable. Variations in appearance of adjoining components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.

2.5 ALUMINUM FINISHES

A. Clear Anodic Finish: AAMA 611, AA-M12C22A31, Class II, 0.010 mm or thicker.

B. Color Anodic Finish: AAMA 611, AA-M12C22A32/A34, Class II, 0.010 mm or thicker.

C. Baked-Enamel or Powder-Coat Finish: AAMA 2603, except with a minimum dry film thickness of 1.5 mils. Comply with coating manufacturer's written instructions for cleaning, conversion coating, and applying and baking finish.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates and conditions, with Installer present, for compliance with requirements for installation tolerances, surface conditions of wall, and other conditions affecting performance of the Work.

B. Examine roughing-in for electrical power systems to verify actual locations of connections before installation of motorized, sliding visual display units.

C. Examine walls and partitions for proper preparation and backing for visual display units.

D. Examine walls and partitions for suitable framing depth where sliding visual display units will be installed.

E. Proceed with installation only after unsatisfactory conditions have been corrected.

VISUAL DISPLAY UNITS 10 11 00 - 6

3.2 PREPARATION

A. Comply with manufacturer's written instructions for surface preparation.

B. Clean substrates of substances, such as dirt, mold, and mildew, that could impair the performance of and affect the smooth, finished surfaces of visual display boards.

C. Prepare surfaces to achieve a smooth, dry, clean surface free of flaking, unsound coatings, cracks, defects, projections, depressions, and substances that will impair bond between visual display units and wall surfaces.

3.3 INSTALLATION

A. General: Install visual display surfaces in locations and at mounting heights indicated on Drawings, or if not indicated, at heights indicated below. Keep perimeter lines straight, level, and plumb. Provide grounds, clips, backing materials, adhesives, brackets, anchors, trim, and accessories necessary for complete installation.

B. Field-Assembled Visual Display Board Assemblies: Coordinate field-assembled units with grounds, trim, and accessories indicated. Join parts with a neat, precision fit.

1. Make joints only where total length exceeds maximum manufactured length. Fabricate with minimum number of joints, balanced around center of board, as acceptable to Architect.

2. Where size of visual display board assemblies or other conditions require support in addition to normal trim, provide structural supports or modify trim as indicated or as selected by Architect from manufacturer's standard structural support accessories to suit conditions indicated.

C. Factory-Fabricated Visual Display Board Assemblies: Attach concealed clips, hangers, and grounds to wall surfaces and to visual display board assemblies with fasteners at not more than 16 inches o.c. Secure tops and bottoms of boards to walls.

3.4 CLEANING AND PROTECTION

A. Clean visual display units according to manufacturer's written instructions. Attach one removable cleaning instructions label to visual display unit in each room.

B. Touch up factory-applied finishes to restore damaged or soiled areas.

C. Cover and protect visual display units after installation and cleaning.

3.5 DEMONSTRATION

A. Owner's maintenance personnel to adjust, operate, and maintain motorized, sliding visual display units.

VISUAL DISPLAY UNITS 10 11 00 - 7

END OF SECTION 10 11 00