W912L718B7001_Amendment_3.pdf

PDF 138 KB Posted

Attached to
Construct Billeting Office Federal contract opportunity
Solicitation number
W912L7-18-B-7001
Issued by
Department of the Army Tennessee Army National Guard

View the file

Other files for this federal contract opportunity

Other files attached to Construct Billeting Office, newest first.
File Type Posted
Abstract_of_offers_18B7001_signed.pdf PDF
W912L718B7001_Amendment_4.pdf PDF
Addendum_AT_FP_Drawing.pdf PDF
W912L718B7001_Amendment_2.pdf PDF
W912L718B7001_Amendment_1.pdf PDF
Specifications_Amendment_1.zip ZIP file
Preproposal_minutes_W912L718B7001.pdf PDF
Site_Visit_Slides_20_Apr_2018.pdf PDF
Sign_in_Sheet.pdf PDF
W912L718B7001_8_Apr_2018.pdf PDF
JA-Brand_Name_Simplex.pdf PDF
Specifications.zip ZIP file
21-17007_134th_Billeting_Office_-_Alcoa,_TN.pdf PDF
Drawings.zip ZIP file
Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

F7X3187324AW01 PSXE132005

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

REASON FOR AMENDMENT: To incorporate questions and answ ers 9-15. Bid due date and time is changed to 16 May 2018, 2:00 P.M.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 2

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 05-May-2018

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912L7-18-B-7001

X 9B. DATED (SEE ITEM 11)

08-Apr-2018

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

05-May-2018

CODE

134TH TN AIR NATIONAL GUARD

134 MSC CONTRACTING OFFICE - WAWF W912L7

240 BRISCOE DRIVE

LOUISVILLE TN 37777-6227

W912L7 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912L7-18-B-7001

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION 00010 - SOLICITATION CONTRACT FORM

The required response date/time has changed from 09-May-2018 02:00 PM to 16-May-2018 02:00 PM.

SECTION 00800 - SPECIAL CONTRACT REQUIREMENTS

The following have been added by full text:

QUESTION AND ANSWER 9-15

9. Question: Does ATFP apply to just the slider doors, the windows A, B, and C -or- the slider doors as well as windows A, B and C? Maybe they could clarify the exact spec needing to be met, instead of "greater than". The spec is ambiguous to say the least: they say low level of protection but use a High load test...see my engineers comments below... Nothing that is aluminum will meet that specification. Weight I at 20’ will create extremely high loads. Kawneer’s tests are based on Weight I at 148’ or Weight II at 82’

9. Answer: ATFP will apply to both sets of automatic sliding doors and window types A, B & C and hollow metal doors and frames. Design is to be governed by UFC 4-010-01 2013 latest edition. The level of protection for this project is “very low”. Design by dynamic analysis for explosive weights I and II with a 30 foot standoff.

10. Question: Specs call for mineral fiber insulation (sab) in interior walls, plans call for R19 fiberglass. Please clarify. Note-R19 is 5 ½” thick and will not fit in 3 5/8” walls as noted on plans.

10. Answer: Substitute R-13 (sab) for R-19in the interior walls.

11. Question: Walls that are called on plans as going to deck, can we take to bottom of metal trusses?

11. Answer: No. The walls provide either thermal or sound isolation and therefore must be continuous to deck.

12. Question: Can we substitute USG ceiling grid and tile with Armstrong equals?

12. Answer: Please see Specification Section 01600 paragraph 1.5. A.2 and

13. Question: Wall type W1 on floor plan calls for 1 ½” hat channel (see details 1-3@A3.2) and R10 rigid, but specs call for rigid to be 2” thick. Please clarify. Also, can we use z-furring in lieu of hat channel?

13. Answer: R-10 is the correct reference. Disregard the thickness in inches. Reference response to question #12.

14. Question: The specs note all the plywood/wood veneers are to be FSC certified. Since this is not a LEED project per Addendum 1, will the FSC certified wood still be required?

14. Answer: No.

15. Question: 07410 Metal Wall Panels, what profile should we use for the wall panels at the fascia? I see one specified for the soffit panels, but not the wall panels.

15. Answer: Can also use the soffit panels (Profile Series IW-10A) for the fascia wall panels. Contrator will need to install the panels vertically