- Threat Assessment Information Checklist -

Minimum Requirements for UFC 4-010-01 Review

Threat assessment information must be known in order for Kawneer to properly perform a product design review and/or bid requests for any project requiring compliance with UFC 4-010-01. The necessary information for threat assessment is outlined below. Provide the Glass Make-up and requested information in Option #1 or Option #2 or Option #3 as noted. Not providing the necessary information will result in a delay of Kawneer’s response

Glass Make-up*

□ Overall Glass - Thickness ________ Air Space - ________

□ Inboard Glass - Thickness ________ Type ____________________ PVB thickness ________

□ Outboard Glass - Thickness ________ Type ____________________

*Required for all options. (Include overall glass thickness, glass type and thickness for each pane (lite), air space, and PVB thickness at inboard pane (lite).

NOTE: Annealed or heat strengthened glass is recommended.)

Option #1 (complete all four sections)

− Building Location: (select one)

□ Controlled perimeter or Parking and Roadways without a controlled perimeter or,

□ Parking and Roadways within a Controlled Perimeter or,

□ Trash Containers

− Building Category: (select one)

□ Billeting and High Occupancy Family Housing or,

□ Primary Gathering

□ Inhabited Building

− Standoff Distance: (select one)

□ 148 ft (45 m) □ 82 ft (25 m) □ 33 ft (10 m)

− Explosive Weight: (select one)

□ Explosive Weight I □ Explosive Weight II □ Explosive Weight I and II

Option #2: (fill out both load requirements) Option #3 (fill out all pressure requirements)

− Frame load = ____________ psf − Peak Blast Pressure = ____________ psi

− Framing − Impulse = ______________________ psi * msec-psi attachment load to building = ____________ psf − Level of protection (select one)

□ Very Low □ Low □ Medium □ High

For architectural design considerations contact the Kawneer AST (Architectural Services Team) Toll free at 1-877-767-9107.

For bid requests contact your local Kawneer Estimating Department.

Rev-001_02-04-2010

1" 1/2"

1/4" LAMINATED .090"

1/4" HEAT STRENGTHENED