PROJECT
LOCATION
E 46TH ST N
N
97TH
E A
V E
OKLAHOMA AIR NATIONAL GUARD - TULSA
XHZG162222 - REPAIR BUILDING 222 BERM SYSTEM
100% CONSTRUCTION DOCUMENTS
138TH FIGHTER WING HEADQUARTERS
TULSA INTERNATIONAL AIRPORT AIR GUARD BASE
TULSA, OKLAHOMA
PROJECT NO. XHZG162222 G-001
COVER SHEET
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A S
E
TU
LS
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
SEAL:
03/16/2017
BASE CIVIL ENGINEER
FIRE CHIEF
ATFP OFFICER
ENVIRONMENTAL MANAGER
BIO ENVIRONMENTAL
COMMUNICATION
BUILDING MANAGER
DATE
DATE
DATE
DATE
DATE
DATE
DATE
DATE
REAL PROPERTY MANAGER DATE DATE
WING COMMAND CHIEF
ARCHITECTS IN PARTNERSHIP, LLC
PROFESSIONAL ENGINEERING
CONSULTANTS (PEC)
SHEET INDEX
GENERAL
G-001 COVER SHEET
ARCHITECTURAL
AD-001 DEMOLITION SITE PLAN
G-002 GENERAL INFORMATION
AD-101 DEMOLITION FLOOR PLAN
AD-201 DEMOLITION EXTERIOR ELEVATIONS
AN-001 NEW SITE PLAN
AN-101 NEW FLOOR PLAN
AN-201 NEW EXTERIOR ELEVATIONS
NOT TO SCALE1 BASE MAP
N
G-003 ATFP SITE PLAN
CIVIL
CE-101 EXISTING SITE PLAN
CN-101 NEW SITE PLAN
CN-102 NEW GRADING AND EROSIONS CONTROL PLAN
CO-100 HAUL ROAD
STRUCTURAL
S-101 BLDG 222
CD-101 EROSION CONTROL DETAILS
AN-301 NEW SECTION DETAILS
PARTITION TYPE
M A T E R I A L S L E G E N D
PLYWOOD
BATT INSULATION
RIGID INSULATION
GYP. BD.
GRAVEL
PLASTER ON
METAL LATH
GYP. SHEATHING
GROUT, MORTAR
OR SAND
EARTH
BRICK
CONCRETE
CMU
ALUMINUM
STEEL
SHEET METAL
HARDWOOD
CEILING TILE
OR CERAMIC TILE
GLASS
DRAWING NUMBER
SECTION NUMBER
SECTION NUMBER
DRAWING NUMBER
DIMENSIONAL LUMBER
CONTINUOUS
DIMENSIONAL LUMBER
BUILDING SECTION
WALL SECTION
S Y M B O L S L E G E N D
BUT NOT TO OTHER DISCIPLINES DRAWING SHEETS.
NON-CONTINUOUS
THE FOLLOWING SYMBOLS APPLY TO ALL ARCHITECTURAL SHEETS
L I S T O F A B B R E V I A T I O N S
MACHINE
MAXIMUM
LIGHT
MANAGER
MINIMUM
METAL
MEMBRANE
MANHOLE
MIRROR
MEDICINE
MANUFACTURER
LIQUID SOAP DISPENSER
LIGHT FIXTURE
MECHANICAL
MICROWAVE OVEN
MATERIAL
MOUNTED
NORTH
ON CENTER
NOMINAL
OVERALL
OFFICE
NUMBER
OWNER FURNISHED/CONTR. INSTALLED
MASONRY OPENING
MOISTURE RESISTANT
MOISTURE RESISTANT GYPSUM BOARD
NOT IN CONTRACT
NOT TO SCALE
OUTSIDE DIAMETER
ON CENTER EACH WAY
MISCELLANEOUS
ADJUSTABLE
AREA DRAIN
ADDITIONAL
ANCHOR BOLT
ACOUSTICAL
ANCILLARY
ALTERNATE
ANODIZED
ALUMINUM
ACCESSIBLE EWC
ADMINISTRATION
ABOVE FINISHED FLOOR
ACOUSTICAL CEILING TILE
ARCHITECT(URAL)
APPROXIMATE(LY)
N
BOARD
BOTTOM OF
BLOCKING
BEARING
BEAM
BLOCK
BUILDING
CENTERLINE
CABINETS
BOTH SIDES
CLEAR
BRICK
BELOW FINISHED FLOOR
CONTROL JOINT
CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
COLD FORMED METAL FRAMING
ARCH'TL WOODWORK INSTITUTE
MET
MGR
NO.(#)
MFR
MTL
MTD
OC/oc
OFCI
MIN
MACH
MAX
LT
LSD
LF
MECH
MED
MEMB
M.H
M.O
MIR
MISC
M.R
MIC. OV
M.R.G.B
N.I.C
O.A N.T.S
NOM.
OD
O.C.E.W
OFF
OPPOSITE
OPERABLE
OPENING
PLYWOOD
PLATE
PLASTER
PAINT
PAIR
PRESERVATIVE PRESSURE TREATED
PHONE (TELEPHONE)
PLASTIC LAMINATE
PORTLAND CEMENT
ORIENTED STRAND BOARD
OPPOSITE HAND
OUTSIDE TO OUTSIDE
OWNER FURNISHED/OWNER INSTALLED
PREPARATION
REFERENCE
PARTITION
RADIUS
REQUIRED
RETAINING
RESILIENT
RESISTANT
REVISION
RECEPTION
REFLECTED CEILING PLAN
REINFORCED
COMBINATION PAPER TOWEL
DISPENSER/RECEPTACLE
QUARRY TILE
ROOF DRAIN
REFRIDGERATOR
ROOM FINISH SCHEDULE
PAPER TOWEL DISPENSER
CLOSET
COLUMN
CONCRETE
CONFERENCE
CONSTRUCTION
CONTINUOUS
CEILING
CARPET
COURSE
CERAMIC TILE
CORRIDOR
COLD ROLLED
CUBIC FOOT
CENTER
COUNTERSINK
CONCRETE MASONRY UNIT
COMPOSITE, COMPOSITION
DIMENSION(S)
DIAMETER
DETAIL
DOUBLE
DEPARTMENT
DEGREE
DISPENSER
DRAWER
EACH
DOWN
DOOR
EAST
ELEVATION
DIVISION
EXPANSION JOINT
DRAWING/DRAWINGS
DRINKING FOUNTAIN
CUBIC YARD
PC
OSB
PPT
PLAM
PLYWD
RE: or REF
RCP
REINF
REC'P
PH
REQ
RET
RESIL
O.H
OPP
O.T.O
OPNG
OPER
OF/OI
PL
PLAS
PT
PR
PREP
P.T.D
PTN
P.T.D/R
Q.T R or RAD
R.D
REFR
RESIST
REV
R.F.S
ADJ
AD
AB
ACT
ALT
AFF
BD
B.O
BM
BFF
CJ
CL
B.S
AWI
CMU
COL
CLG
CPT
CRS
CT
CR
CTR
DIA
DF
DET
EA
EJ
DN
DR
E
EL
DIV
DWG/DWG'S
DIM/DIM'S
DWR
ANCIL
CORR
CONST
CONT
CONC
CONF
BLK'G
ANOD/AN
AEWC
ADMIN
ALUM/AL
ADD'L
ACOUS
CLO
BRG
ARCH
APPROX
CF/CI
BRK
CAB
BLDG
BLK
CFMF
CLR
COMP
CU.FT
CTSK
DBL
CU.YD
DEG
DEPT
DISP
VESTIBULE
REFERENCE
DOOR SCHEDULE
ROOM NAME
ROOM NUMBER
COLUMN GRID
USED FOR CONSTR
LETTER DESIGNATION
DETAIL NUMBER
DRAWING NUMBER
DETAIL NUMBER
DRAWING NUMBER
DOOR NUMBER
ROOM REFERENCE
DIMENSION GRID LINE
ELEVATION REFERENCE
DETAIL REFERENCE
REFERENCE OR DATUM
BUILDING
NORTH
NORTH
LC
CL
OR
TO
NORTH
NORTH
L
4'-6"
FACE TO FACE OF STUD
FACE TO FACE OF MAS
COLUMN TO FACE OF MAS OR STUD
DETAIL LETTER
POINT
REFERENCE TO DIMENSION
NORTH REFERENCE
REVISION REFERENCE
CENTER LINE
ARROW POINTS NORTH
BUILDING NORTH IS SET
WHEN BLDG IS ANGLED
WINDOW TYPE/ FRAME TYPE
INTERIOR ELEV MARKER
C
DRAWING NUMBER
ARROW POINTS TO
ELEVATION DRAWN
COLUMN
COLUMN
SCHEDULE
ROOM
SOUTH
SECTION
SHEET
SECRETARY
SHEATHING
SHOWER
SHELF
SIMILAR
ROOF TOP UNIT (HVAC)
SOLID CORE WOOD DOOR
RAIN WATER CONDUCTOR
ROUGH OPENING
RUSTICATION JOINT
SOAP DISPENSER
SANITARY NAPKIN DISPENSER
STEEL
STAIN
STATION
SQUARE
STANDARD
STORAGE
TREAD
TELEPHONE
TOWEL BAR
STRUCTURAL
SUSPEND(ED)
STAIN & VARNISH
SERVICE SINK
STAINLESS STEEL
SYMMETRICAL
TOILET/SHOWER
TOP OF CURB
SANITARY NAPKIN RECEPTACLE
S
EXISTING
ELEVATOR
ELECTRICAL
EMERGENCY
ENCLOSURE
ENGINEER
EQUAL
EQUIPMENT
EXTERIOR
FAN COIL UNIT
FLOOR DRAIN
EXPANSION
EXPOSED
FIRE ALARM
FOUNDATION
FINISHED FLOOR
ELECTRIC WATERCOOLER
T
FLOOR
FRAME
FLASHING
FINISH
FLEXIBLE
FIRE RATED
GRAB BAR
FURRING
FURNISHED
FOOTING
GAUGE
FOOT or FEET
FIELD VERIFY
GALVANIZED
FIRE EXTINGUISHER CABINET
FIRE RETARDANT TREATED
FIRE EXTINGUISHER
RTU
SECT
SCWD
RWC
SCHED/SCH
STL
SHT
STN
SHTH'G
SUSP
S&V
SEC'Y
RO
R.J
RM
SD
SHR
SH
STA
S.SK
S.S
SQ
S.N.R S.N.D
SIM
STD
STOR
STR
SYM
T/S
TEL
T.B T.C
TOP OF
TERRAZZO
THICK(NESS)
TYPICAL
TELEVISION
URINAL
UNDERWRITERS LABORATORIES
TOP OF LIGHTWEIGHT CONCRETE
TOP OF WALL
TEMPERED/ TEMPORARY
TOP OF GRATE
TOP OF MASONRY
TOP OF STEEL
TOUNGE AND GROOVE
TOP OF PAVEMENT
TOILET PAPER DISPENSER
UNLESS OTHERWISE NOTED
VESTIBULE
WOOD
WEST
WITH
WITHOUT
WEIGHT
WAINSCOT
VINYL COMPOSITION TILE
VINYL WALL COVERING
WATER CLOSET
VERTICAL
GENERAL
GYPSUM
GLOSS LEVEL
GLAZING
GRADE
HARDWARE
HOUR
HARDWOOD
HORIZONTAL
HEIGHT
GALVANIZED IRON
HOLLOW METAL
HEATING-VENTILATION-AIR CONDITIONING
ELECTRICAL GROUND
HOLLOW CORE or
HANDICAP ACCESSIBLE
INSIDE DIAMETER
W
JANITOR
JOINT
INTERIOR
JOIST
LABORATORY
KNOCKDOWN
KITCHEN
LAVATORY
LAMINATED
INSULATION, INSULATED
INCHES
TG
T.O
TLWC
T.O.M
TV
TYP
T.O.W/T.W T.O.S.
VWC
VCT
VEST
VERT
WD
UL
TEMP
TER
T&G
THK
T.P T.P.D
U.N.O
UR
W/ W.C
WT
WSCT
W/O
EQ
FF
FD
FCU
EXT
FA
FDN
FRM
FEC
FLR
FIN
FLG
FR
GA
GB
FTG
FT
FV
FRT
FE
GI
G.L.
GEN
GR
HC
HM
HR
HT
I.D
JT
JAN
INT
JST
K.D
LAB
KIT
LAV
LAM
IN
FURR'G
FURN
EWC
EXIST/EXG
ELEV
ELEC
HDW
GYP
FLASH or
EXP
INSUL/INS
HVAC
ENGR
ENCL
EMER
EQUIP
EXPO
FLEX
GALV
GLAZ
GND
HDWD
HORIZ
COLUMN GRID LINE COLUMN NUMBER AND
SANITARY SEWERSS 4A4A
GENERAL ARCHITECTURAL NOTES
HOT WATER HEATERHWH
AIR WATER VAPOR BARRIERAWV
GYPSUM BOARDGWB
1. THE CONTRACTOR SHALL NOTIFY THE BASE CIVIL ENGINEER IMMEDIATELY OF DISCREPANCIES IN THE DRAWINGS, BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, AND/OR BETWEEN THE CONSTRUCTION DOCUMENTS AND ACTUAL JOB
CONDITIONS WHICH AFFECT THE EXECUTION OF THE WORK AS INDICATED.
2. CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL CONSTRUCTION WORK PERFORMED BY
SUBCONTRACTORS UNLESS NOTED OR INDICATED OTHERWISE.
3. CONTRACTOR SHALL LOCATE AND LAYOUT WALLS AND PARTITIONS AS THEY RELATE TO THE STRUCTURE AND OTHER BUILDING ELEMENTS AS SHOWN IN THE CONSTRUCTION DOCUMENTS. CONFLICTS OR AREAS OF INTERPRETATION SHALL BE
RESOLVED BY THE BASE CIVIL ENGINEER.
4. CONTRACTOR SHALL VERIFY AND CORRELATE ALL DIMENSIONS DURING THE CONSTRUCTION LAYOUT OF THE WORK. THE
FOLLOWING GUIDANCE APPLIES TO DIMENSIONS USED ON THE ARCHITECTURAL DRAWINGS.
4.1. THE CONTRACTOR SHALL USE DIMENSIONS INDICATED ON THE DRAWINGS.
4.2. THE CONTRACTOR SHALL NOT SCALE FROM THE DRAWINGS.
4.3. THE CONTRACTOR SHALL NOTIFY THE BASE CIVIL ENGINEER OF DISCREPANCIES IN DIMENSIONS SHOWN ON THE
DRAWINGS IMMEDIATELY.
4.4. ALL PLAN DIMENSIONS ARE TO THE STRUCTURAL GRID LINES OR TO THE CENTERLINE OF COLUMNS AND BEAMS, TO
THE ACTUAL FACE OF METAL STUDS OR FURRING CHANNELS (GYPSUM BOARD PARTITIONS), OR TO THE NOMINAL FACE
OF MASONRY UNITS UNLESS NOTED OR INDICATED OTHERWISE.
4.5. ALL PLAN DIMENSIONS ON EXTERIOR WALL ASSEMBLIES ARE FROM THE ACTUAL OUTSIDE FACE OF WALL TO THE ACTUAL INSIDE FACE METAL STUDS OR CMU OF WALL UNLESS NOTED OR INDICATED OTHERWISE.
4.6. ALL OTHER MASONRY DIMENSIONS ARE INDICATED AS NOMINAL DIMENSIONS WHICH INCLUDES AN ALLOWANCE FOR +
OR - 3/8" MORTAR JOINT UNLESS NOTED OR INDICATED OTHERWISE.
4.7. ALL MASONRY OPENING DIMENSIONS ARE INDICATED AS NOMINAL DIMENSIONS WHICH INCLUDES AN ALLOWANCE FOR
+ OR - 3/8" MORTAR JOINT UNLESS NOTED OR INDICATED OTHERWISE.
5. THE CONTRACTOR SHALL MAINTAIN THE INTEGRITY OF THE FIRE STOPPING AND THE FIRE RESISTANT ASSEMBLIES OF MATERIALS IN COMPLIANCE WITH THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS OF THE REFERENCED UL ASSEMBLIES. THESE MATERIALS SHALL BE REAPPLIED OR REPAIRED TO MAINTAIN THE REQUIRED BARRIER AT NO
ADDITIONAL COST TO THE GOVERNMENT.
6. THE CONTRACTOR SHALL SCRIBE GYPSUM BOARD ON FIRE RESISTANT PARTITIONS TO THE IRREGULARITIES OF THE
STRUCTURE AS DETAILED ON THE DRAWINGS UNLESS NOTED OR INDICATED OTHERWISE.
7. THE CONTRACTOR SHALL COORDINATE REQUIRED PENETRATIONS THROUGH FIRE RESISTANT PARTITIONS AND SEAL
TIGHTLY AROUND THE PENETRATION UNLESS NOTED OR INDICATED OTHERWISE.
8. THE CONTRACTOR SHALL FILL ANY OTHER IRREGULAR OPENINGS OR GAPS IN FIRE RESISTANT PARTITIONS AND SEAL TIGHTLY AROUND THE PENETRATION WITH THE SPECIFIED INERT NONCOMBUSTIBLE FIRESAFING MATERIAL UNLESS NOTED
OR INDICATED OTHERWISE.
9. ALL PARTITIONS SHALL EXTEND A MINIMUM OF 6" ABOVE THE CEILING HEIGHT AND BE BRACED TO THE STRUCTURE AT 4'-0"
O.C. UNLESS NOTED OR INDICATED OTHERWISE.
10. THE CONTRACTOR SHALL PROVIDE CONCEALED FIRE-TREATED WOOD BLOCKING WHERE REQUIRED IN METAL STUD PARTITIONS FOR THE PROPER ANCHORAGE OF WALL ATTACHED ITEMS SUCH AS GRAB BARS, TOILET ACCESSORIES, TACKBOARDS, MARKERBOARDS, SHELF BRACKETS AND SHELVING, MILLWORK, AND ALL OTHER WALL ATTACHED MATERIALS
UNLESS NOTED OR OTHERWISE INDICATED.
11. THE CONTRACTOR SHALL MAKE ALL EXTERIOR WALL/ROOF OR WALL/WALL TRANSITIONS WEATHER TIGHT AND AIRTIGHT WITH SEALANT TO MAINTAIN REQUIRED INSULATION VALUES IN THE FACILITY UNLESS NOTED OR INDICATED OTHERWISE.
NO GAPS, OPENINGS OR PENETRATIONS IN THE EXTERIOR WALL OR ROOF ASSEMBLIES SHALL BE LEFT EXPOSED TO THE
ELEMENTS.
SPECIFICATION NOTES
REFER TO UNIFIED FACILITIES CRITERIA (UFC) SPECIFICATIONS UNDER COVER SEPARATE FROM THESE DOCUMENTS.
APPLICABLE DESIGN CRITERIA
NAME EDITION
INTERNATIONAL BUILDING CODE (IBC)
NFPA 70: NATIONAL ELECTRIC CODE
UNIFIED FACILITIES CRITERIA (UFC) 1-200-01:
GENERAL BUILDING REQUIREMENTS
UNIFIED FACILITIES CRITERIA (UFC) 4-010-01: DOD
MINIMUM ANTITERRORISM STANDARDS FOR
BUILDINGS
X
X
STATE CODE ADOPTION
INTERNATIONAL EXISTING BUILDING CODE (IEBC)X
INTERNATIONAL FIRE CODE (IFC)X
INTERNATIONAL FUEL GAS CODE (IFGC)X
INTERNATIONAL MECHANICAL CODE (IMC)X
INTERNATIONAL PLUMBING CODE (IPC)X
NATIONAL ELECTRIC CODE (NEC)X
ADDITIONAL CODES
X
X
16 AUG 2010 WITH CHANGE 2, 28 NOV 2011
9 FEB 2012 INCLUDING CHANGE 1, 1 OCT 2013
G-002
GENERAL
INFORMATION
SCHEDULE SUBMITTAL
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
SEAL:
03/16/2017
CO
NTRO
LLED PERIM
ETER
C C
S D
6' -0
M
IN
S
TA
N
D O
FF
'-0
48'-0"
BUILDING 222
G-003
ATFP SITE
PLAN
NORTH
ATFP SITE PLAN
SCALE: 1" = 10'-0"01
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
SEAL:
03/16/2017
AFTP SITE LEGEND
CONVENTIONAL CONSTRUCTION
STANDOFF DISTANCE (CCSD)
MINIMUM STANDOFF DISTANCE
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
WAN
RGB
EXISTING SITE
PLAN
CE-101
TDS
AI
MD=???
AC
ELEC
WALK
WALL
CONC
WALL
WALK
W A
LK
W A
LL
AC
SPGT
WALL
ELEC
WALK
CONC
WALK
W A
LK
SPGT
ELEC
WALL
WALK
CONC
WALK
W A
LK
SPGT
SPR
INLET
MD=???
INLET
MD=???
CAMERAEO
COMPRESSOR
HOSE REEL
EOEOEOEOEO
EO EO
EO
EO
EO
AC
EB ANTENNA
EB
ANTENNA
SWITCH
BOX
EO
CO
CO
STMH
MD=
WM
WV
24" RCP
O
D
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
WAN
RGB
TDS
NEW SITE
PLAN
CN-101
AI
MD=???
AI
AC
ELEC
WALK
WALL
CONC
WALL
WALK
W A
LK
W A
LL
AC
SPGT
WALL
ELEC
WALK
CONC
WALK
W A
LK
SPGT
INLET
ELEC
WALL
WALK
CONC
WALK
W A
LK
SPGT
SPR
INLET
MD=???
INLET
MD=???
CAMERAEO
COMPRESSOR
HOSE REEL
EOEOEOEOEO
EO EO
EO
EO
EO
AC
EB ANTENNA
EB
ANTENNA
SWITCH
BOX
EO
GREASE
TRAP
GREASE
TRAP
CO
CO
STMH
MD=
WM
WV
24" RCP
MAY GO TO
GUARD
SHACK
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
WAN
RGB
TDS
NEW GRADING AND
EROSION CONTROL
PLAN
CN-102
WAN
RGB
TDS
C0-100
HAUL ROAD
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
WAN
RGB
TDS
EROSION
CONTROL
DETAILS
CD-101
16 March 2017
RE: Tulsa Air National Guard Building 222 Berm Removal
To whom it may concern:
The existing berms are to be removed and a thin set brick veneer will be adhered to the face of existing concrete wall. The new condition has been evaluated and the load demand to capacity ratio is decreased for the existing concrete wall and foundation.
Therefore, the existing structural system has adequate capacity and requires no modifications.
Respectfully, James G. Holt, PE, SE Structural Division 405-735-8939 Direct 618-593-6370 Mobile
Professional Engineering Consultants, P.A.
10017 S. Pennsylvania Ave.
Oklahoma City, OK 73159 www.pec1.com
1617B
REMOVE EXISTING BERM
REMOVE EXISTING CONCRETE
LOW RETAINING WALL TYP.
'-5
'-5
'-2
32'-8"
10'-8"22'-0"
'-0
'-5
'-5
'-0
22'-0" 33'-0"
55'-0" 44'-0"
79'-0"
101'-0"
22'-0"
'-0
9'
-0
'-0
'-0
22'-0"12'-0"
34'-0"13'-0"
24'-8"7'-4"
32'-0"
REMOVE EXISTING BERM
REMOVE EXISTING
CONCRETE RETAINING
WALL
REMOVE EXISTING
CONCRETE PAD
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
REMOVE EXISTING
CONDENSER AND
STORE FOR
REINSTALLATION
REMOVE EXISTING
CONCRETE RETAINING
WALL TYP.
REMOVE EXISTING BERM
REMOVE EXISTING CONCRETE
LOW RETAINING WALL TYP.
REMOVE EXISTING
CONCRETE LOW
RETAINING WALL TYP.
REMOVE EXISTING BERM
REMOVE EXISTING CONCRETE
LOW RETAINING WALL TYP.
BUILDING 222
FF = 608.60
NO WORK IN SHADED AREA
EXISTING COMM LINES UNDER EXISTING BERM
AND SIDEWALK. REFER TO CIVIL FOR
INSTRUCTIONS ON REMOVAL AND
REINSTALLATION.
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING GAS METER..
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
AD-201
AD-201
AD-201
AD-201
AD-001
DEMOLITION
SITE PLAN
NORTH
DEMOLITION SITE PLAN
SCALE: 1" = 10'-0"01
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
REMOVE EXISTING CONCRETE
LOW RETAINING WALL TYP.
REMOVE EXISTING CONCRETE
LOW RETAINING WALL TYP.
REMOVE EXISTING CONCRETE
LOW RETAINING WALL TYP.
REMOVE EXISTING CONCRETE
LOW RETAINING WALL TYP.
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
REMOVE EXISTING
CONCRETE LOW
RETAINING WALL TYP.
EXISTING RIGID
INSULATION TO
BE REMOVED
EXISTING RIGID
INSULATION TO
BE REMOVED
EXISTING RIGID
INSULATION TO
BE REMOVED
EXISTING RIGID
INSULATION TO
BE REMOVED
5'-10"
'-7
'-7
29'-2"
19'-10" 11'-2"
'-4
75'-2"
AD-101
TYP
BUILDING 222
FF = 608.60
NO WORK IN
SHADED AREA
A
REMOVE EXISTING
CONCRETE RETAINING
WALL TYP.
12'-0"
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING GAS METER..
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
AD-201
AD-201
AD-201
AD-201
8' -0
8"
7' -4
EXISTING SOIL
TO REMAIN
REMOVE EXISTING
2" RIGID INSULATION
REMOVE EXISTING
SOIL BERM
CLEAN WALL AND
PREP FOR NEW
FLUID APPLIED
WATERPROOFING
AD-101
DEMOLITION
FLOOR PLAN
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
SEAL:
03/16/2017
NORTH
DEMO FLOOR PLAN
SCALE: 1/8"=1'-0"01
02 SCALE: 3/4"=1'-0"
DEMO WALL SECTION
A
INTERIOR DEMOLITION NOTE (ROOM 17)
EXISTING OFFICE FURNITURE TO BE RELOCATED BY
CONTRACTOR. COVER AND PROTECT FURNITURE
DURING CONSTRUCTION. REMOVE EXISTING CEILING
TILES AND GRID ADJACENT TO SOUTH WALL AND STORE
FOR REINSTALLATION. REMOVE 12' WIDE X 8' TALL
SECTION OF EXISTING DAMAGED GYP. BD., INSULATION
AND WALL BASE DOWN TO EXISTING STRUCTURAL WALL.
PREP EXISTING WALL FRAMING FOR INSTALLATION OF
NEW GYP. BD.
GENERAL SOIL REMOVAL NOTE:
REFER TO CIVIL FOR INSTRUCTIONS ON SOIL
REMOVAL, STOCKPILES AND REUSE.
AD-101
TYP
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVIL
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVILREMOVE EXISTING
CONCRETE RETAINING
WALL TYP.
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
EXISTING ALUMINUM
FRAMED GLAZING
AD-101
TYP
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVIL
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVIL
REMOVE EXISTING
MECHANICAL SCREEN WALLS
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
AD-101
TYP
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVIL
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVIL
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
EXISTING OVERHEAD
DOOR TYP.
EXISTING GAS METER..
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
AD-101
TYP
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVIL
REMOVE EXISTING
LOW RETAINING
WALL
REMOVE EXISTING
SOIL BERM
REFER CIVIL
REMOVE EXISTING
CONCRETE RETAINING
WALL TYP.
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
EXISTING ALUMINUM
FRAMED GLAZING
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING GAS METER.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
AD-201
DEMOLITION
EXTERIOR
ELEVATIONS
01 SCALE: 1/8"=1'-0"
DEMO SOUTH ELEVATION
02 SCALE: 1/8"=1'-0"
DEMO EAST ELEVATION
03 SCALE: 1/8"=1'-0"
DEMO NORTH ELEVATION
04 SCALE: 1/8"=1'-0"
DEMO WEST ELEVATION
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
NEW RIVER ROCK PLANTING
BED OVER WEED VEGETATION
BARRIER TYP. WHERE HATCHED
'-5
'-5
'-2
32'-8"
10'-8"22'-0"
'-0
'-5
'-5
'-0
22'-0" 33'-0"
55'-0" 44'-0"
79'-0"
101'-0"
22'-0"
'-0
9'
-0
'-0
'-0
22'-0"12'-0"
34'-0"13'-0"
24'-8"7'-4"
32'-0"
NEW 4" CONCRETE
PAD AND RELOCATED
CONDENSER UNIT
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
NEW SOD TYP.
WHERE HATCHED
BUILDING 222
FF = 608.60
NO WORK IN SHADED AREA
NEW METAL TURF
EDGING AT RIVER
ROCK PLANTING BED TYP.
REFER TO 02/AN-001
NEW AND EXISTING COMM LINES UNDER
NEW GRADE AND EXISTING SIDEWALK. REFER
TO CIVIL FOR INSTRUCTIONS ON REMOVAL
AND REINSTALLATION.
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING GAS METER..
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
AN-201
AN-201
AN-201
AN-201
LAWN OR
STEEL LANDSCAPE
EDGING 3/16" X 4"
RIVER ROCK
BED
15" STEEL STAKE
GROUND COVER
SUBGRADE
WEED
BARRIER
TOPSOIL
AN-001
NEW SITE PLAN
NORTH
NEW SITE PLAN
SCALE: 1" = 10'-0"01
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
SEAL:
03/16/2017
SITE PLAN LEGEND:
NEW SOD
NEW RIVER ROCK OVER
EXISTING BACKFILL
02 SCALE: NO SCALE
LANDSCAPE EDGING DETAIL
AN-301
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
5'-11 5/8"
'-8
/8
'-2
'-8
/8
'-7
/4
29'-3 5/8" 52'-0" 75'-3 5/8"
156'-7 1/4"
'-7
/4
12'-3 5/8"12'-0"1'-6"3'-4"20'-10"
49'-11 5/8"
BUILDING 222
FF = 608.60
NO WORK IN
SHADED AREA
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
EXISTING RETAINING
WALL TO REMAIN
AN-301
TYP
TYP
A
12'-0"
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING GAS METER..
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
AN-201
AN-201
AN-201
AN-201
AN-101
NEW FLOOR
PLAN
NORTH
NEW FLOOR PLAN
SCALE: 1/8"=1'-0"01
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
SEAL:
03/16/2017
A
INTERIOR CONSTRUCTION NOTE (ROOM 17)
INSTALL 12' WIDE X 8' TALL NEW GYP. BD., WALL
INSULATION AND WALL BASE TO MATCH EXISTING. TAPE,
BED AND TEXTURE NEW GYP. WALL. PAINT TO MATCH
EXISTING. REINSTALL EXISTING CEILING TILES AND GRID.
MOVE OFFICE FURNITURE BACK TO EXISTING LOCATION.
AN-301
TYP
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
INSTALL (2) TWO NEW DUCT BANKS AND
NEW COMM LINES UNDER NEW GRADE
AND EXISTING SIDEWALK. REFER
TO CIVIL FOR INSTRUCTIONS ON REMOVAL
AND REINSTALLATION.
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
EXISTING ALUMINUM
FRAMED GLAZING
AN-301
TYP
GENTLY WASH AND
CLEAN CONC. PANEL EXPOSED
FROM REMOVAL OF
SOIL BERM TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
GENTLY WASH AND
CLEAN CONC. PANEL EXPOSED
FROM REMOVAL OF
SOIL BERM TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
AN-301
TYP
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
EXISTING OVERHEAD
DOOR TYP.
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING GAS METER.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
AN-301
TYP
EXISTING COMM EQUIPMENT.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
EXISTING GAS METER.
COORDINATE ADJUSTMENT TO
NEW GRADE WITH OWNER.
GENTLY WASH AND
CLEAN CONC. PANEL EXPOSED
FROM REMOVAL OF
SOIL BERM TYP.
NEW THIN BRICK ON
THICK MORTAR SETTING
BED OVER METAL LATHE
ON 2" RIGID INSULATION
OVER FLUID APPLIED
VAPOR BARRIER TYP.
EXISTING METAL
WALL PANEL TYP.
EXISTING MASONRY
SOLDIER COURSE TYP.
EXISTING ALUMINUM
FRAMED GLAZING
AN-201
NEW EXTERIOR
ELEVATIONS
01 SCALE: 1/8"=1'-0"
NEW SOUTH ELEVATION
02 SCALE: 1/8"=1'-0"
NEW EAST ELEVATION
03 SCALE: 1/8"=1'-0"
NEW NORTH ELEVATION
04 SCALE: 1/8"=1'-0"
NEW WEST ELEVATION
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
7' -4
8" 6'
-0
8"
NEW WEED
VEGETATION BARRIER
NEW 2" RIVER ROCK TO
BE 4" THICK AND
SUFFICIENTLY COVER
THE NEW WEED BARRIER
EXISTING PRECAST
WALL PANEL
NEW 2" RIGID
INSULATION BOARD
NEW 5/8" THICK
ADHERED
MANUFACTURED
BRICK VENEER
AN-301
AN-301
AN-301
NEW FLUID APPIED
WATER BARRIER
NEW 2" RIGID
INSULATION BOARD
NEW METAL LATH
NEW LATH FASTENER
6 INCHES EACH WAY
NEW THICK MORTAR
BED SETTING
NEW 5/8" THICK ADHERED
MANUFACTURED
BRICK VENEER
NEW 2" RIVER ROCK TO BE 4"
THICK AND SUFFICIENTLY COVER
THE NEW WEED BARRIER
WEEP SCREED
1" 4"
M
IN
ELASTOMERIC PAINT AT
EXPOSED CONC.
4" M
IN
NEW FLASHING MEMBRANE
NEW FLUID APPIED
WATER BARRIER
NEW 2" RIGID
INSULATION BOARD
NEW METAL LATH
NEW LATH FASTENER
6 INCHES EACH WAY
NEW THICK MORTAR
BED SETTING
NEW 5/8" THICK ADHERED
MANUFACTURED
BRICK VENEER
EXISTING WALL
SHOWN SHADED
1/2" BEAD AND CAULK
CONTINUOUS AT NEW
BRICK VENEER
NEW FLUID APPIED
WATER BARRIER
NEW 2" RIGID
INSULATION BOARD
NEW METAL LATH
NEW LATH FASTENER
6 INCHES EACH WAY
NEW THICK MORTAR
BED SETTING
NEW 5/8" THICK ADHERED
MANUFACTURED
BRICK VENEER
EXISTING WALL
SHOWN SHADED
1/2" BEAD AND CAULK
CONTINUOUS AT NEW
BRICK VENEER
NEW FLUID APPIED
WATER BARRIER
NEW 2" RIGID
INSULATION BOARD
NEW METAL LATH
NEW LATH FASTENER
6 INCHES EACH WAY
NEW THICK MORTAR
BED SETTING
NEW 5/8" THICK ADHERED
MANUFACTURED
BRICK VENEER
EXISTING WALL
SHOWN SHADED
AN-301
NEW SECTION
DETAILS
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D
XH
ZG
TU
LS
A A
IR
N
A
TI
O N
A L
G U
A R
D B
A
A , O
K
LA
H O
M A
03/16/2017
1617B
SHEET NO.:
SHEET TITLE:
PROJECT NO.:
DATE:
CHECKED BY:
PROJ. MANAGER:
DRAWN BY:
DATEREV. DESCRIPTION
REVISIONS
SEAL:
ARCHITECTS
IN
3220 MARSHALL AVENUE
NORMAN, OK 73072
TEL: 405.360.1300
FAX: 405.360.1431
CSM
GL
R E
P A
IR
B
U
IL
D
IN
G
B
E R
M S
Y S
TE
M
BKW
SEAL:
03/16/2017
01 SCALE: 3/4"=1'-0"
NEW WALL SECTION
NORTH
PLAN DETAIL
SCALE: 3"=1'-0"05
03 SCALE: 3"=1'-0"
NEW WALL SECTION DETAIL
02 SCALE: 3"=1'-0"
NEW WALL SECTION DETAIL
04 SCALE: 3"=1'-0"
NEW WALL SECTION DETAIL
3 5/8"
3 5/8"
3 5/8"
3 5/8"
File details come from the government source that posted it.