SHEET NO:
SHEET TITLE:
PROJECT NUMBER:
COPYRIGHT © 2016
DATE ISSUE
26913 NORTHWESTERN HWY
SUITE 200
SOUTHFIELD, MICHIGAN
48033 | USA
(T) 248 262 1500
WWW.HED.DESIGN
2016-01686-000
Selfridge Air
National Guard
Base
SANG 117 & 126 Mechanical
Renovation
Harrison Township, MI 48045
SANG Project No.: VGLZ 162045
M5-01
Mechanical Details
SCALE : NO SCALE
"X"
VOLUME DAMPER
AIR FLOW
"W"
"L"
"X"
"X"
"X"
AIR FLOW
AIR FLOW
AIR FLOW
VOLUME DAMPER
VOLUME DAMPER
L =1/2 W OR 4" MIN.
SHEETMETAL
REDUCER FTG.
DOUBLE WIDTH AIR
TURNING VANES
SHEETMETAL
REDUCER FTG.
SHEETMETAL
REDUCER FTG.
DOUBLE WIDTH AIR
FOIL TURNING VANES
NOTE: BRANCH TAKE-OFFS TO BE LOCATED IN CENTER OF REDUCER FITTINGS.
SUPPLY AIR DUCT CONNECTION DETAILS
SCALE : NO SCALE
RETURN AIR BRANCH
DUCT CONNECTION DETAIL
MAIN DUCT (SEE FLOOR PLAN FOR SIZE)
MANUAL VOLUME DAMPER
AIR
FLOW
A I R
F L O
W
1 1/2 OF "D"
15 DEG. F
15 DEG. F TRANSITION TO
OCCUR PRIOR TO EXHAUST OR
RETURN DUCT CONNECTION
"D" (SIZE AS INDICATED
ON FLOOR PLAN)
SPLAY IN DIRECTION
OF AIR FLOW. OF
AIR FLOW. MAINTAIN
DEPTH OF BRANCH
DUCT
BRANCH EXHAUST OR
RETURN DUCT
6" MIN.
45 DEG. F
MIN.
SCALE : NO SCALE
HOT WATER HEATING COIL PIPING DIAGRAM
(WITH CIRC. PUMP AND 3-WAY CONTROL VALVE)
R
E
T
U
R
N
L
I
N
E
S
U
P
P
Y
I
N
E
CALIBRATED BALANCE
VALVE (TYP)
3-WAY CONTROL VALVE
NC
NO
C
BALL VALVE
(TYP)
STRAINER
REDUCER (TYP)
CIRCULATING PUMP (HHWP-1, HHWP-2)
CHECK VALVE (TYP)
MANUAL AIR
VENT (TYP)
PIPING TO OTHER
COIL(S) IN SAME
COIL BANK
HEATING
COIL
AIR
FLOW
PRESSURE GAUGE
(TYP)
THERMOMETER (TYP)
FLEX CONNECTION
(TYP) NOTES 2 & 3
3.
1. PROVIDE VALVES AND FITTINGS, AS INDICATED, FOR EACH
COIL (WHERE MULTIPLE COIL BANKS ARE INSTALLED)
NOTES:
FLEXIBLE HOSE ASSEMBLY MAY BE USED IN
USED IN LIEU OF FLEXIBLE CONNECTORS
AT COIL CONNECTIONS.
2. PROVIDE FLEXIBLE CONNECTORS AT
LOCATIONS SHOWN IF ASSOCIATED AHU FAN
IS NOT INTERNALLY ISOLATED.
11/15/16 CD (65%) Submittal
01/13/17 Pre-Final (95%) Submittal
MINIMUM 6" LONG
FULL SIZE
DIRT POCKET
UNION
GAS SERVICE
VALVE
DOUBLE DEFLECTION
SUPPLY GRILLE
PROVIDE CROSS
BRACING TWO
DIRECTIONS
ALL THREAD
SUSPENSION
ROD (TYP.)
G
SCALE : NO SCALE
TYPICAL GAS UNIT HEATER DETAIL
SUPPLY AIR
FLEX
CONNECTOR
(TYP.) SUPPLY
DUCT
WAF-126-2A
MECHANICAL
ROOM
FLOOR
SUPPORT RETURN
DUCT FROM FLOOR
(TYP.)
RETURN AIR
PROVIDE FURNACE
SUPPORT FRAME
SUFFICIENT HEIGHT TO ALLOW
INSTALLATION OF RETURN
DUCT AND FILTER MEDIA BOX
UNDER FURNACE
ALL WELDED
GALVANIZED
STEEL ANGLE
FURNACE SUPPORT
FRAME
FILTER MEDIA BOX
AT BOTTOM. FURNACE
RETURN AIR INLET
ACCESSIBLE FROM FRONT
OF FURNACE
SCALE : NO SCALE
FRONT VIEW TWINNED FURNACES DETAIL
WAF-126-2A/WAF-126-2B AND WAF-126-3A/WAF-126-3B
SUPPLY
DUCT
WAF-126-3A
WAF-126-2B
WAF-126-3B
FLEX
CONNECTOR
(TYP.)
SUPPLY AIR
SUPPLY
DUCT
WAF-126-2A
MECHANICAL
ROOM
FLOOR
SCALE : NO SCALE
SIDE VIEW TWINNED FURNACES DETAIL
WAF-126-2A/WAF-126-2B AND WAF-126-3A/WAF-126-3B
WAF-126-3A
FLEX
CONNECTION
DX-126-2A
DX-126-3A
DX-126-2B
DX-126-3B
DX-126-2A
DX-126-3A
RETURN AIR
FILTER MEDIA CABINET
ACCESS FROM
FRONT OF FURNACE
FLEX
CONNECTION
EXPANSION BOLT
FURNACE SUPPORTS
FRAM TO FLOOR
PROVIDE DIAGONAL
BRACE BOTH ENDS
SUPPORT RETURN AIR
DUCT FROM FLOOR
(TYP.)
ALL WELDED
GALVANIZED
FURNACE
SUPPORT
FRAME
02/08/17 Final (100%) Submittal
2/7/2017 10:50:55 AM
| M-401 |
| M5-01 |