SHEET NO:
SHEET TITLE:
PROJECT NUMBER:
COPYRIGHT © 2016
DATE ISSUE
26913 NORTHWESTERN HWY
SUITE 200
SOUTHFIELD, MICHIGAN
48033 | USA
(T) 248 262 1500
WWW.HED.DESIGN
2016-01686-000
Selfridge Air
National Guard
Base
SANG 117 & 126 Mechanical
Renovation
Harrison Township, MI 48045
SANG Project No.: VGLZ 162045
M-G1
Mechanical Symbols and
Legends Buildings 117&126
RISE
DROP
CEILING DIFFUSER (SQUARE OR RECTANGULAR)
LINEAR SLOT DIFFUSER
SUPPLY REGISTER
SENSING DEVICE WITH
AVERAGING TYPE ELEMENT
SENSING DEVICE WITH
RIGID TYPE ELEMENT
SENSING DEVICE WITH
RIGID TYPE ELEMENT
MOUNTED IN WELL
POSITION SWITCH
(LIMIT SWITCH)
LEVEL ELEMENT
(PROBE TYPE)
PRESSURE SENSING ELEMENT
(L=LOW, H=HIGH)
M
ZS
SD
H
L
AS
I
T
NEW PIPE
EXIST. PIPE
NEW CONNECTION TO EXISTING
REFRIGERANT DISCHARGERD
RS REFRIGERANT SUCTION
REFRIGERANT LIQUIDRL
NON-POTABLE HOT WATER
NPCW NON-POTABLE COLD WATER
FUEL OIL RETURNFOR
FOS FUEL OIL SUPPLY
ENERGY RECOVERY RETURNERR
ERS ENERGY RECOVERY SUPPLY
GLYCOL WATER RETURNGWR
GWS GLYCOL WATER SUPPLY
CONDENSER WATER RETURNCWR
CWS CONDENSER WATER SUPPLY
CHILLED WATER RETURNCHWR
CHWS CHILLED WATER SUPPLY
HEATING HOT WATER RETURN
HHWR
HHWS HEATING HOT WATER SUPPLY
EXISTING PIPE TO BE REMOVED
PIPING DESIGNATIONS
MISCELLANEOUS SYMBOLS
STEAM TRAP
UNION
STRAINER
FLOOR DRAIN (F.D.)FD-X
PIPE ANCHOR
EXPANSION JOINT
THERMOMETER
WATER HAMMER ARRESTER
REDUCER OR INCREASER
FLANGES
DRIP POCKET
PITCH DOWN IN DIRECTION OF FLOW
FIRE HYDRANT (F.H.)
BRANCH CONNECTION OUT OF SIDE
CAPPED TEE
AUTOMATIC FIRE SPRINKLER RISER (ASR)
FIRE DEPARTMENT CONNECTION (SIAMESE) (FDC)
FIRE PROTECTION SPRINKLER HEAD (UPRIGHT)
FIRE PROTECTION SPRINKLER HEAD (PENDENT)
SIDEWALL FIRE PROTECTION SPRINKLER HEADS
FIRE PUMP TEST HEADER
FIN TUBE RADIATION
GENERAL DUCTWORK SYMBOLS
6"
FLEXIBLE DUCT
SUPPLY AIR/OSA DUCT UP
DOUBLE LINE DUCTWORK SYMBOLS
EXISTING DUCT TO BE REMOVED
CEILING DIFFUSER (ROUND)
FLEXIBLE DUCT CONNECTION
DUCT TRANSITION
INCLINED DROP WITH RESPECT TO AIR FLOW
INCLINED RISE WITH RESPECT TO AIR FLOW
D
R
AD
20X20
12X12
ACOUSTICALLY LINED DUCT
DUCT SIZE (A=SIDE SHOWN, B=SIDE NOT SHOWN)
AXB
SINGLE LINE DUCTWORK SYMBOLS
EXISTING DUCT TO REMAIN
EXISTING DUCT TO BE REMOVED
DUCT ELBOW DOWN
DUCT ELBOW UP
FLEXIBLE CONNECTION
DUCT TRANSITION
INCLINED DROP WITH RESPECT TO AIR FLOW
INCLINED RISE WITH RESPECT TO AIR FLOW
AD
ACOUSTICALLY LINED DUCT
AXB
CONTROL SYMBOLS
FLOW SWITCH
SMOKE DETECTOR
POWER WIRING
ELECTRICAL/ELECTRONIC
PNEUMATIC SIGNAL
INSTRUMENT AIR SUPPLY
CONTROL SIGNAL WIRING
INTERLOCK
(NOTE: ARROWS ON LINES
INDICATE CONTROL LOGIC FLOW)
MOTOR
VIA HARDWIRE CONNECTION
FLEXIBLE CONNECTOR PIPE
NPHW
DEIONIZED WATERDI
A COMPRESSED AIR
MEDICAL COMPRESSED AIRMA
VAC VACUUM
NITROUS OXIDE
N2
NITROGEN
OXYGENO2
STEAM (INDICATE PSI __ )
HPWR
HPWS HEAT PUMP WATER SUPPLY
HEAT PUMP WATER RETURN
PRESSURE GAUGE AND COCK
PUR PURIFIED WATER
HORIZONTAL FIRE DAMPER
HORIZONTAL SMOKE DAMPER
HORIZONTAL FIRE/SMOKE DAMPER
SOUND ATTENUATOR
SA
ACCESS DOOR
MANUAL VOLUME DAMPER
ACCESS DOOR
MANUAL VOLUME DAMPER
HVC
HVC
HVC
HOSE VALVE CABINET
(SURFACE MOUNTED)
HOSE VALVE CABINET
(SURFACE MOUNTED - STAIRWELL)
HOSE VALVE CABINET
(RECESSED)
MOTORIZED DAMPER
AUTOMATIC AIR VENT
MANUAL AIR VENT
FLOW SWITCH
MV
FS
AV
STRAINER WITH BLOW DOWN VALVE
DIGITAL INPUT
DIGITAL OUTPUT
ANALOG OUTPUT
ANALOG INPUT
LIGHT TROFFER DIFFUSER
LINEAR SLOT DIFFUSER
SUPPLY REGISTER
NO
STM __
COND __ CONDENSATE (INDICATE PSI __ )
PLUMBING DESIGNATIONS
HORIZONTAL OR WALL CLEAN OUT
FLOOR CLEANOUT OR CLEANOUT AT GRADE
PIPE CAP
PIPE DROP
PIPE RISE
45 OR 90 DEGREES OFF TOP
45 OR 90 DEGREES OFF BOTTOM
DUCT SIZE (A=SIZE IN VIEW, B=SIZE IN DEPTH)
VERTICAL FIRE/SMOKE DAMPER WITH ACCESS DOOR
VERTICAL SMOKE DAMPER WITH ACCESS DOOR
VERTICAL FIRE DAMPER WITH ACCESS DOOR
MITERED ELBOW WITHOUT TURNING VANES
MITERED ELBOW WITH TURNING VANES
VERTICAL FIRE/SMOKE DAMPER WITH ACCESS DOOR
VERTICAL SMOKE DAMPER ACCESS DOOR
VERTICAL FIRE DAMPER ACCESS DOOR
PRESSURE TEMPERATURE TAP
THERMOSTAT
FLANGED CONNECTION
AUTOMATIC CONTROL DAMPER
M
STRUCTURAL STEEL OPENING (SEE STRUCT. DWGS.)
SHUT-OFF VALVE IN YARD BOX
DROP OR RISE
VALVE IN VERTICAL
VVB
XXX
VVB
XXX
SUPPLY AIR/OSA DUCT DN
EXHAUST AIR UP
EXHAUST AIR DN
CVB
XXX
RB/EB
XXX
DETAIL DESIGNATION
SHEET NO.
DETAIL NO.
Ø DIAMETER
SQUARE FOOT
LOUVER (DOOR OR WALL)
AND FREE AREA
FA
DOMESTIC COLD WATER
DOMESTIC HOT WATER
DOMESTIC HOT WATER RETURN
LAB WASTE VENTLV
PLUMBING VENT PIPING
DRAIN TILE CONNECTION
ST
LAB WASTELW
SAN
SHW
SCW
D DRAIN
SOFT COLD WATER
SOFT HOT WATER
GW GREASE WASTE
TP TRAP PRIMER LINE
TEMPERED WATER
TEMPERED WATER RETURN
OVERFLOW STORM DRAIN
TWR
OSD
TW
V ATMOSPHERIC VENT
G NATURAL GAS
SPRINKLER PIPESP
F FIRE LINE
PC
T
D&T
STEAM DRIP AND TRAP ASSEMBLY
SAN WASTE BELOW GRADE
WASTE ABOVE GRADE
ST STORM BELOW GRADE
STORM ABOVE GRADE
PIPE SLEEVE OR GUIDE
TEMPERATURE AND PRESSURE TEST PLUG
AUTOMATIC FLOW CONTROL VALVE
INDICATES DIRECTION OF FLOW
FLOW MEASURING STATION
VALVE SYMBOLS
RELIEF OR SAFETY VALVE
THREE-WAY ELECTRONIC CONTROL VALVE
TWO-WAY ELECTRONIC CONTROL VALVE
GLOBE VALVE
GATE VALVE
BALL VALVE
PRESSURE REDUCING VALVE
ANGLE VALVE
BUTTERFLY VALVE
PLUG VALVE
NON-FREEZE WALL HYDRANT
WH
WALL
S
OUTSIDE STEM & YOKE GATE VALVE
BALANCING VALVE (SEE SPECS)
BFP BACKFLOW PREVENTER
CHECK VALVE
(ARROW INDICATES FLOW DIRECTION)
SOLENOID VALVE
DRAIN VALVE
HOSE VALVE
PRESSURE RELIEF VALVE
P&T
PRESS.AND TEMP. RELIEF VALVE
VARIABLE VOLUME BOX W/REHEAT COIL
(XXX=DESIGNATION)
CONSTANT VOLUME BOX W/REHEAT COIL
(XXX=DESIGNATION)
VARIABLE VOLUME BOX
(XXX=DESIGNATION)
RETURN/EXHAUST AIR BOX
(XXX=DESIGNATION)
CEILING SUPPLY AIR DIFFUSER (ROUND)
CEILING SUPPLY AIR DIFFUSER (SQUARE OR RECTANGULAR)
CEILING RETURN AIR GRILLE (SQUARE OR RECTANGULAR)
CEILING EXHAUST AIR GRILLE (SQUARE OR RECTANGULAR)
AUTOMATIC CONTROL DAMPER
BDD
ACD
AUTOMATIC CONTROL DAMPER
BACKDRAFT DAMPER
BACKDRAFT DAMPER
BDD
ACD
DUCT CAP
RETURN AIR DUCT UP
RETURN AIR DUCT DN
EXISTING PIPE TO REMAIN
THREE-WAY PNEUMATIC CONTROL VALVE
TWO-WAY PNEUMATIC CONTROL VALVE
HW
CW
HWR
MISCELLANEOUS SYMBOLS (CONTINUED)
SINGLE LINE DUCTWORK SYMBOLS
STRAINER
TRIPLE DUTY VALVE
NOTE:
NOT ALL SYMBOLS INDICATED MAY
APPLY ON THIS PROJECT.
LIGHT TROFFER DIFFUSER
EXISTING DUCT TO REMAIN
PUMPED CONDENSATE
10/11/16 Preliminary (35%) Submittal
11/15/16 CD (65%) Submittal
01/13/17 Pre-Final (95%) Submittal
02/08/17 Final (100%) Submittal