T

T

SHEET NO:

SHEET TITLE:

PROJECT NUMBER:

COPYRIGHT © 2016

DATE ISSUE

26913 NORTHWESTERN HWY

SUITE 200

SOUTHFIELD, MICHIGAN

48033 | USA

(T) 248 262 1500

WWW.HED.DESIGN

2016-01686-000

Selfridge Air

National Guard

Base

SANG 117 & 126 Mechanical

Renovation

Harrison Township, MI 48045

SANG Project No.: VGLZ 162045

MD-01

Mechanical Demolition Plan

Building 117

SCALE:

BUILDING 117 MECHANICAL DEMOLITION PLAN

1/8"=1'-0"

REMOVE EXISTING

ACU-1 EQUIPMENT

PAD, CONTROLS,

SUPPORTS AND

REFRIGERANT PIPING

CUT-OFF EXISTING

SUPPLY DUCT SUFFICIENT

DISTANCE TO ALLOW

REMOVAL OF EXISTING

UNIT AND INSTALLATION OF

NEW UNIT

NOTES:

REMOVE EXISTING HEATING HOT WATER PIPING TO EXISTING AIR

HANDLING UNITS SUFFICIENT DISTANCE TO ALLOW REMOVAL OF

UNIT AND INSTALLATION OF NEW UNIT.

REMOVE ALL HVAC-1 REFRIGERANT PIPING.

RECLAIM ALL REFRIGERANT FROM HVAC-1 SYSTEM AND

AND TURN OVER TO BASE HVAC SHOP IN BUILDING 126.

REMOVE ALL EXISTING HVAC-1 AND HV-3 CONTROLS.

09/30/16 35% Estimate

10/11/16 Preliminary (35%) Submittal

(E) 16"x10"

(E) 10"x10"

(E) 6"x10"

(E) 26"x26"

(E) 18"x12"

(E) EF-4

TO REMAIN

(E) 8"x8"

(E) 4"x10"

(E) 16"x14"

(E) 12"x12"

(E) 8"x12"

(E) EF-5

TO REMAIN

EXISTING

EXHAUST

LOUVER

(E) 16"x14"

REMOVE EXISTING

DIFFUSERS AND

BRANCH DUCTS

(E) 14"x12"

(E) 36"x16"

(E) 12"x12"

(E) 18"x10"

(E) 36"x22"

(E) 36"x26"

(E) 18"x12"

(E) 26"x12"

(E) 36"x20"

(E) 18"x10"

(E) 10"x12"

(E) 14"x12"

EXISTING OUTDOOR

AIR INTAKE LOUVER

(E) 14"x10"

(E) 10"x8"

(E) 36"x16"

(E) 36"x20"

(E) 8"x10"

EXISTING RELIEF

AIR LOUVER

SEE M4-01 FOR

ENLARGED DEMO PLAN

OF EQUIPMENT

PLATFORM ABOVE

CEILING

(E) 28"x12"

(E)

12"x10"

11/15/16 CD (65%) Submittal

CUT-OFF EXISTING RELIEF

DUCT SUFFICIENT DISTANCE

TO ALLOW REMOVAL OF

EXISTING AND INSTALLATION OF

NEW UNIT

CUT-OFF EXISTING SUPPLY

DUCT SUFFICIENT DISTANCE

TO ALLOW REMOVALOF

EXIST. UNIT AND

INSTALLATION OF

NEW UNIT

REMOVE

(E) SUPPLY

FROM HV-3

ON EQUIPMENT

PLATFORM

CUT-OFF

EXISTING

RETURN DUCT

SUFFICIENT

DISTANCE TO

ALLOW REMOVAL

OF EXISTING UNIT

AND INSTALLATION

UNIT

(E) SUPPLY DUCT

FROM HVAC-1

ON EQUIPMENT

PLATFORM

REMOVE

(E) RETURN

DUCT FROM

HV-3 ON

EQUIPMENT

PLATFORM

REMOVE

(E) RETURN

DUCT FROM HVAC-1

ON EQUIPMENT

PLATFORM

REMOVE EXISTING

TWO-CIRCUIT

DUCTLESS SPLIT

SYSTEM OUTDOOR

UNIT INCLUDING

ALL REFRIGERANT

PIPING, CONTROLS,

AND EQUIPMENT PAD

REMOVE EXISTING

CEILING MOUNTED

DUCTLESS SPLIT

SYSTEM INDOOR

UNIT CONTROL AND

REFRIGERATION PIPING

EXISTING DUCTLESS

SPLIT SYSTEM

OUTDOOR UNIT

TO REMAIN

01/13/17 Pre-Final (95%) Submittal

EXISTING

EXHAUST

LOUVER

N

EXISTING RELIEF

AIR LOUVER

REMOVE EXISTING WINDOW AIR

CONDITIONING UNIT

REMOVE EXISTING WINDOW AIR

CONDITIONING UNIT

WINDOW REPAIR NOTE:

RESTORE EXISTING WINDOWS TO THEIR ORIGINAL CONDITION

WHERE EXISTING AIR CONDITIONING UNITS ARE SHOWN TO BE

REMOVED. REFURBISH WINDOWS BACK TO THEIR ORIGINAL

WORKING CONDITION, REPLACED GLASS REMOVED TO

ACCOMMODATE AIR CONDITIONING UNITS. RESTORE EXISTING

WINDOW OPENING TO MATCH EXISTING. TYPICAL TWO LOCATIONS.

02/08/17 Final (100%) Submittal

2/7/2017 10:06:35 AM

AutoCAD SHX Text

ENGINE SHOP BAY AREA

AutoCAD SHX Text

BEARING ROOM

AutoCAD SHX Text

HAZ WASTE ROOM

AutoCAD SHX Text

EQUIP STORAGE ROOM

AutoCAD SHX Text

ENGINE MANAGER

AutoCAD SHX Text

ENG NCOIC & JEIM NCOIC OFFICE

AutoCAD SHX Text

COMPUTER & TRAINING ROOM

AutoCAD SHX Text

MXS - COMMANDER & 1ST SGT OFFICE

AutoCAD SHX Text

MXS- OIC & NCOIC OFFICE

AutoCAD SHX Text

MXS- ADMIN OFFICE

AutoCAD SHX Text

ENG SHOP BREAKROOM

AutoCAD SHX Text

ENGINE SHOP BAY AREA

AutoCAD SHX Text

BEARING ROOM

AutoCAD SHX Text

HAZ WASTE ROOM

AutoCAD SHX Text

EQUIP STORAGE ROOM

AutoCAD SHX Text

ENGINE MANAGER

AutoCAD SHX Text

ENG NCOIC & JEIM NCOIC OFFICE

AutoCAD SHX Text

COMPUTER & TRAINING ROOM

AutoCAD SHX Text

MXS - COMMANDER & 1ST SGT OFFICE

AutoCAD SHX Text

MXS- OIC & NCOIC OFFICE

AutoCAD SHX Text

MXS- ADMIN OFFICE

AutoCAD SHX Text

ENG SHOP BREAKROOM

AutoCAD SHX Text

ENG SHOP TOOL CRIB

AutoCAD SHX Text

ENG SHOP EQUIP STORAGE

AutoCAD SHX Text

KEYPLAN

AutoCAD SHX Text N