SCBA Fill Station with Compressor
Solicitation number
W912JA-25-Q-A003
Issued by

About this file

This Statement of Requirement (SOR) details specifications for one Self-Contained Breathing Apparatus (SCBA) bottle filling station with compressor required by the 46th CST-WMD in Alabama to support CBRN RECON operations. The equipment must meet NFPA and CFR standards, with key requirements including the ability to fill two SCBA bottles simultaneously, two 6000 psi fill bank tanks, digital carbon monoxide/water monitoring, and a 10 HP/14 cfm compressor operating on 60 Hz, 1-phase, 208/230V power.

The system must comply with NFPA 1901, CGA, and OSHA standards and include safety features like automatic start/stop controls, safety shutdown switches, and an enclosure designed to contain high-pressure incidents. Delivery is required to Montgomery, AL with government inspection upon receipt. The contractor must provide standard manufacturer's warranty coverage and all equipment documentation including owner's and service manuals. Technical specifications include 76 dB maximum noise level at one meter and a purification system capable of processing 35,000 cubic feet of air at 70°F compressed to 6000 psi between cartridge changes.