This Statement of Requirement (SOR) details specifications for one Self-Contained Breathing Apparatus (SCBA) bottle filling station with compressor required by the 46th CST-WMD in Alabama for CBRN RECON operations. The equipment must comply with NFPA and CFR 1910.120 standards.

Key technical requirements include: ability to fill two SCBA bottles simultaneously, minimum of two 6000 psi Fill Bank tanks, digital carbon monoxide and water monitoring, noise level below 76 DB at one meter, and 208/230V single-phase power. The system must feature automatic compressor start/stop, safety shutdown switches, auto-drain condensate reservoir, and process 35,000 cubic feet of air at 70°F compressed to 6000 psi between cartridge changes. Delivery is required to Montgomery, AL with inspection/acceptance at delivery. The contractor must provide standard manufacturer's warranty and all equipment documentation including owner's and service manuals.

View the file

Other files

File Type Posted
Statement of Requirement.pdf PDF
Q and As.pdf PDF
Statement of Requirement.pdf PDF
Statement of Requirement.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Statement of Requirement (SOR)

1. General Information

New requirement for Self-Contained Breathing Apparatus (SCBA) bottle filling station with compressor to support CBRN RECON operations. This equipment is required by the 46th CST-WMD in Alabama to refill air bottles and ensure operational readiness, as well as maintain health standards within National Fire Protection Association (NFPA) and 29 Code of Federal Regulations (CFR) 1910.120.

1.1. CLIN0001: Qty 001, SCBA Fill Station with Compressor

1.2. Specifications

General Requirements:

1) Must be able to fill at least two SCBA Bottles at the same time

2) Must have a minimum of two 6000 psi Fill Bank tanks

3) Must have Digital Carbon monoxide and water monitoring

4) Noise shall not exceed 76 DB at one meter

5) Must be NFPA 1901, Compressed Gas Association (CGA) and Occupational Safety and Health Administration (OSHA) compliant

6) 60 Hertz Current - 1 Phase, 208/230 volts

7) Air pressure switch to automatically start and stop the compressor based on demand

8) Low oil pressure shutdown switch

9) Compressor access door safety shutdown switch

10) Auto-drain condensate reservoir capacity shutdown switch with illuminated indicator

11) The purification system shall be sized to process 35,000 cubic feet of air at 70°F and compressed to 6000 psi between cartridge changes

12) Safety relief valve

13) Drain valve to relieve the system pressure for maintenance.

14) The enclosure shall be designed to contain the impact of suddenly expanded high pressure air and all displaced fragments in the unlikely event of a cylinder or fill component rupture.

2. Delivery, Inspection and Acceptance

2.1. Place of Delivery: 3101 Tine Avenue, Montgomery, AL 36108

2.2. Inspection and acceptance will occur at time of delivery by a government representative. A comprehensive bill of lading or delivery receipt shall accompany all deliverables that details, at minimum, all serial numbers associated with the requested cascade system and internal equipment.

3. Warranty

3.1. All equipment shall have the standard manufacturer’s warranty. The Contractor shall warranty all items delivered and ensure all items are free from defects in material and workmanship under normal use and service. Additionally, without charge, repair or replace any equipment found to be defective in material or workmanship provided said equipment has been operated within standard procedures and instructions and such defects are not due to abuse, misuse or Acts of God.

4. Documentation

4.1 The contractor shall provide all owner’s manuals, service manuals and any other manufacturer documentation that accompanies the purchase of this item. If any equipment installed has its own service and owner’s manual these will also be provided by the contractor.