Text version
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
P L
T
C A
L E
D R
A W
N
B
Y
A P
P R
O V
E D
B
Y
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
N
B Y
A R
H
I T
E
A
L
L I F
E
C
Y C
L
S
E T
S
F s t
R
S C
F O
M
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
I S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
W
H P
D
T A
K
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-001
M E
C H
A N
I C
B
R E
V I A
T I O
N S
S
Y M
B O
T
E S
D A
B
L V
T
R H
U
N O
N E
AutoCAD SHX Text
SYMBOLS
AutoCAD SHX Text
CAP/PLUG
AutoCAD SHX Text
AUTOMATIC AIR VENT
AutoCAD SHX Text
GAS COCK
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
RELIEF VALVE (HYDRONIC USE)
AutoCAD SHX Text
MANUAL AIR VENT
AutoCAD SHX Text
AUTOMATIC 3-WAY CONTROL VALVE
AutoCAD SHX Text
3-WAY VALVE, MANUAL
AutoCAD SHX Text
STOP COCK, PLUG VALVE
AutoCAD SHX Text
LOCK SHIELD VALVE
AutoCAD SHX Text
GLOBE VALVE
AutoCAD SHX Text
GATE VALVE
AutoCAD SHX Text
SOLENOID VALVE
AutoCAD SHX Text
AUTOMATIC 2-WAY CONTROL VALVE
AutoCAD SHX Text
SQUARE HEAD COCK
AutoCAD SHX Text
CALIBRATED BALANCING VALVE
AutoCAD SHX Text
BALL VALVE
AutoCAD SHX Text
2-WAY MODULATING CONTROL VALVE
AutoCAD SHX Text
CHECK VALVE
AutoCAD SHX Text
BUTTERFLY VALVE
AutoCAD SHX Text
CHILLED WATER SUPPLY
AutoCAD SHX Text
CHILLED WATER RETURN
AutoCAD SHX Text
CWS
AutoCAD SHX Text
CWR
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text M
AutoCAD SHX Text
AV
AutoCAD SHX Text
OS&Y VALVE
AutoCAD SHX Text
SHUTOFF VALVE (BALL, GATE, OR BUTTERFLY)
AutoCAD SHX Text
CALIBRATED AUTOMATIC FLOW VALVE
AutoCAD SHX Text
VALVES
AutoCAD SHX Text
PIPING
AutoCAD SHX Text
TRIPLE DUTY VALVE
AutoCAD SHX Text A
AutoCAD SHX Text
TEE
AutoCAD SHX Text
FLOW ARROW
AutoCAD SHX Text
PIPE GUIDE
AutoCAD SHX Text
PIPE ANCHOR
AutoCAD SHX Text
STRAINER W/BLOW OFF
AutoCAD SHX Text
CONCENTRIC REDUCER
AutoCAD SHX Text
TEE, TURNED DOWN
AutoCAD SHX Text
STRAINER
AutoCAD SHX Text
GAUGE W/COCK
AutoCAD SHX Text
FLEXIBLE CONNECTOR
AutoCAD SHX Text
EXPANSION LOOP
AutoCAD SHX Text
ELBOW, TURNED DOWN
AutoCAD SHX Text
ELBOW, TURNED UP
AutoCAD SHX Text
UNION OR FLANGE
AutoCAD SHX Text
TEE, TURNED UP
AutoCAD SHX Text
FLOW SWITCH
AutoCAD SHX Text
THERMOMETER
AutoCAD SHX Text
VACUUM BREAKER
AutoCAD SHX Text
PRESSURE SWITCH
AutoCAD SHX Text
SLEEVE
AutoCAD SHX Text
PUMP
AutoCAD SHX Text V
AutoCAD SHX Text X
AutoCAD SHX Text
PS
AutoCAD SHX Text
FS
AutoCAD SHX Text
PIPE PITCH DOWN
AutoCAD SHX Text
HOSE FITTING
AutoCAD SHX Text
ECCENTRIC REDUCER
AutoCAD SHX Text
PIPING COMPONENTS
AutoCAD SHX Text 12X12
AutoCAD SHX Text
DL
AutoCAD SHX Text
COMBINATION LINE STARTER
AutoCAD SHX Text
DOOR LOUVER
AutoCAD SHX Text
DISCONNECT SWITCH
AutoCAD SHX Text
DETECTOR, SMOKE
AutoCAD SHX Text
EQUIPMENT OR
AutoCAD SHX Text
FLEXIBLE DUCT
AutoCAD SHX Text
SOUND TRAP
AutoCAD SHX Text
ST
AutoCAD SHX Text
ACCESS DOORS, VERTICAL
AutoCAD SHX Text
AUTOMATIC DAMPER
AutoCAD SHX Text
OR
AutoCAD SHX Text 12X20
AutoCAD SHX Text
MANUAL VOLUME DAMPER
AutoCAD SHX Text
DUCT, FIRST VALUE
AutoCAD SHX Text
FIRE DAMPER
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
VIBRATION ISOLATOR
AutoCAD SHX Text
UNDERCUT DOOR
AutoCAD SHX Text
THERMOSTAT OR
AutoCAD SHX Text
HAND OFF AUTO SWITCH
AutoCAD SHX Text
MOTOR OPERATOR, ELECTRIC
AutoCAD SHX Text
AIR DIRECTION
AutoCAD SHX Text
CEILING MOUNTED GRILLE
AutoCAD SHX Text U
AutoCAD SHX Text
DIFFUSER, 4-WAY BLOW
AutoCAD SHX Text
SMOKE DAMPER
AutoCAD SHX Text
TAGS
AutoCAD SHX Text
HVAC COMPONENTS
AutoCAD SHX Text
FIRE/SMOKE DAMPER
AutoCAD SHX Text
VD
AutoCAD SHX Text
MOTOR OPERATED DAMPER
AutoCAD SHX Text H
AutoCAD SHX Text M
AutoCAD SHX Text
BACKDRAFT DAMPER
AutoCAD SHX Text
BDD OR GBDD
AutoCAD SHX Text T
AutoCAD SHX Text
CONNECTION
AutoCAD SHX Text
TO EXISTING
AutoCAD SHX Text
PLAN
AutoCAD SHX Text
REMOVE TO LIMIT
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
NEW
AutoCAD SHX Text
EXISTING EQUIPMENT MARK
AutoCAD SHX Text
ELEMENTS TO BE REMOVED
AutoCAD SHX Text
CEILING MOUNTED
AutoCAD SHX Text
XX-# ###
AutoCAD SHX Text
AIR DEVICE TAG AIRFLOW (CFM)
AutoCAD SHX Text
XX
AutoCAD SHX Text
AutoCAD SHX Text
NEW EQUIPMENT MARK ON NEW WORK SHEETS
AutoCAD SHX Text
EQUIPMENT TO BE DEMOLISHED MARK ON DEMO SHEETS
AutoCAD SHX Text M
AutoCAD SHX Text
OR HORIZONTAL
AutoCAD SHX Text
IS SIDE SHOWN
AutoCAD SHX Text
CONTROL PANEL
AutoCAD SHX Text
TEMPERATURE SENSOR
AutoCAD SHX Text
OR REGISTER
AutoCAD SHX Text
EXHAUST GRILLE
AutoCAD SHX Text
ABBREVIATIONS
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
PRV
AutoCAD SHX Text
POWER ROOF VENTILATOR
AutoCAD SHX Text
PVC
AutoCAD SHX Text
POLYVINYL CHLORIDE
AutoCAD SHX Text
RA
AutoCAD SHX Text
RETURN AIR
AutoCAD SHX Text
RD
AutoCAD SHX Text
ROOF DRAIN
AutoCAD SHX Text
RF
AutoCAD SHX Text
RETURN FAN
AutoCAD SHX Text
RG
AutoCAD SHX Text
RETURN GRILLE
AutoCAD SHX Text
RGH
AutoCAD SHX Text
RADIANT GAS HEATER
AutoCAD SHX Text
RH
AutoCAD SHX Text
RELATIVE HUMIDITY
AutoCAD SHX Text
REH
AutoCAD SHX Text
RELIEF HOOD
AutoCAD SHX Text
RL
AutoCAD SHX Text
REFRIGERANT LIQUID
AutoCAD SHX Text
RPM
AutoCAD SHX Text
REVOLUTIONS PER MINUTE
AutoCAD SHX Text
RR
AutoCAD SHX Text
RETURN REGISTER
AutoCAD SHX Text
RS
AutoCAD SHX Text
REFRIGERANT SUCTION
AutoCAD SHX Text
RTU
AutoCAD SHX Text
ROOFTOP UNIT
AutoCAD SHX Text
SA
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
SAN
AutoCAD SHX Text
SANITARY
AutoCAD SHX Text
SCH
AutoCAD SHX Text
SCHEDULE
AutoCAD SHX Text
SF
AutoCAD SHX Text
SUPPLY FAN
AutoCAD SHX Text
SFU
AutoCAD SHX Text
SUPPLY FIXTURE UNITS
AutoCAD SHX Text
SG
AutoCAD SHX Text
SUPPLY GRILLE
AutoCAD SHX Text
SH
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
SHT
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SP
AutoCAD SHX Text
STATIC PRESSURE
AutoCAD SHX Text
FP
AutoCAD SHX Text
FIRE PROTECTION
AutoCAD SHX Text
SPEC
AutoCAD SHX Text
SPECIFICATION
AutoCAD SHX Text
SR
AutoCAD SHX Text
SUPPLY REGISTER
AutoCAD SHX Text
SS
AutoCAD SHX Text
STAINLESS STEEL
AutoCAD SHX Text
ST
AutoCAD SHX Text
SOUND TRAP
AutoCAD SHX Text
SD
AutoCAD SHX Text
SMOKE DAMPER
AutoCAD SHX Text
TD
AutoCAD SHX Text
TRENCH DRAIN
AutoCAD SHX Text
TEMP
AutoCAD SHX Text
TEMPERATURE
AutoCAD SHX Text
TF
AutoCAD SHX Text
TRANSFER FAN
AutoCAD SHX Text
TG
AutoCAD SHX Text
TRANSFER GRILLE
AutoCAD SHX Text
TO
AutoCAD SHX Text
TRANSFER OPENING
AutoCAD SHX Text
TP
AutoCAD SHX Text
TRAP PRIMER
AutoCAD SHX Text
TSP
AutoCAD SHX Text
TOTAL STATIC PRESSURE
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TYPICAL
AutoCAD SHX Text
UD
AutoCAD SHX Text
UNDERCUT DOOR
AutoCAD SHX Text
UH
AutoCAD SHX Text
UNIT HEATER
AutoCAD SHX Text V
AutoCAD SHX Text
VENT
AutoCAD SHX Text
VAC
AutoCAD SHX Text
VACUUM
AutoCAD SHX Text
VCO
AutoCAD SHX Text
VERTICAL CLEANOUT
AutoCAD SHX Text
VD
AutoCAD SHX Text
VOLUME DAMPER
AutoCAD SHX Text
VERT
AutoCAD SHX Text
VERTICAL
AutoCAD SHX Text
VFD
AutoCAD SHX Text
VARIABLE FREQUENCY DRIVE
AutoCAD SHX Text
VTR
AutoCAD SHX Text
VENT THRU ROOF
AutoCAD SHX Text
WB
AutoCAD SHX Text
WET BULB
AutoCAD SHX Text
WC
AutoCAD SHX Text
WATER CLOSET
AutoCAD SHX Text
WCO
AutoCAD SHX Text
WALL CLEANOUT
AutoCAD SHX Text
WG
AutoCAD SHX Text
WATER GAUGE
AutoCAD SHX Text
WH
AutoCAD SHX Text
WATER HEATER
AutoCAD SHX Text
WPD
AutoCAD SHX Text
WATER PRESSURE DROP
AutoCAD SHX Text
WW
AutoCAD SHX Text
WASTE WATER
AutoCAD SHX Text
FOT
AutoCAD SHX Text
FLAT ON TOP
AutoCAD SHX Text
FPM
AutoCAD SHX Text
FEET PER MINUTE
AutoCAD SHX Text
FPS
AutoCAD SHX Text
FEET PER SECOND
AutoCAD SHX Text
FRP
AutoCAD SHX Text
FIBERGLASS REINFORCED PLASTIC
AutoCAD SHX Text
FT
AutoCAD SHX Text
FEET
AutoCAD SHX Text
FTR
AutoCAD SHX Text
FIN TUBE RADIATIOR
AutoCAD SHX Text
FV
AutoCAD SHX Text
FLUSH VALVE
AutoCAD SHX Text G
AutoCAD SHX Text
GAS/GRILLE
AutoCAD SHX Text
GAL
AutoCAD SHX Text
GALLONS
AutoCAD SHX Text
GBDD
AutoCAD SHX Text
GRAVITY BACKDRAFT DAMPER
AutoCAD SHX Text
GC
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text
GPM
AutoCAD SHX Text
GALLONS PER MINUTE
AutoCAD SHX Text
GR
AutoCAD SHX Text
CHASIS GREASE
AutoCAD SHX Text
GRD
AutoCAD SHX Text
GROUND
AutoCAD SHX Text
HB
AutoCAD SHX Text
HOSE BIBB
AutoCAD SHX Text
HC
AutoCAD SHX Text
HVAC CONTRACTOR
AutoCAD SHX Text
HWR
AutoCAD SHX Text
HEATING WATER RETURN
AutoCAD SHX Text
HWS
AutoCAD SHX Text
HEATING WATER SUPPLY
AutoCAD SHX Text
HOA
AutoCAD SHX Text
HAND OFF AUTO SWITCH
AutoCAD SHX Text
HORIZ
AutoCAD SHX Text
HORIZONTAL
AutoCAD SHX Text
HP
AutoCAD SHX Text
HORSEPOWER
AutoCAD SHX Text
HUH
AutoCAD SHX Text
HORIZONTAL UNIT HEATER
AutoCAD SHX Text
HW
AutoCAD SHX Text
HOT WATER
AutoCAD SHX Text
HWHC
AutoCAD SHX Text
HOT WATER HEATING COIL
AutoCAD SHX Text
HZ
AutoCAD SHX Text
FREQUENCY
AutoCAD SHX Text
IH
AutoCAD SHX Text
INFRARED HEATER
AutoCAD SHX Text
INV EL
AutoCAD SHX Text
INVERT ELEVATION
AutoCAD SHX Text
IRR
AutoCAD SHX Text
INDUSTRIAL RETURN REGISTER
AutoCAD SHX Text
ISR
AutoCAD SHX Text
INDUSTRIAL SUPPLY REGISTER
AutoCAD SHX Text
IW
AutoCAD SHX Text
INDUSTRIAL WASTE
AutoCAD SHX Text
KW
AutoCAD SHX Text
KILOWATTS
AutoCAD SHX Text
LAT
AutoCAD SHX Text
LEAVING AIR TEMPERATURE
AutoCAD SHX Text
LAV
AutoCAD SHX Text
LAVATORY
AutoCAD SHX Text
LBS
AutoCAD SHX Text
POUNDS
AutoCAD SHX Text
LDB
AutoCAD SHX Text
LEAVING DRY BULB TEMPERATURE
AutoCAD SHX Text
LLG
AutoCAD SHX Text
TANK LIQUID LEVEL GAUGE LINE
AutoCAD SHX Text
LM
AutoCAD SHX Text
TANK LEAKAGE MONITORING LINE
AutoCAD SHX Text
LPG
AutoCAD SHX Text
LIQUEFIED PETROLEUM GAS
AutoCAD SHX Text
LRA
AutoCAD SHX Text
LOCKED ROTOR AMPS
AutoCAD SHX Text
LD
AutoCAD SHX Text
LINEAR DIFFUSER
AutoCAD SHX Text
LWB
AutoCAD SHX Text
LEAVING WET BULB TEMPERATURE
AutoCAD SHX Text
LWT
AutoCAD SHX Text
LEAVING WATER TEMPERATURE
AutoCAD SHX Text
MAU
AutoCAD SHX Text
MAKE UP AIR UNIT
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MBH
AutoCAD SHX Text
1000 BTUH
AutoCAD SHX Text
MC
AutoCAD SHX Text
MECHANICAL CONTRACTOR
AutoCAD SHX Text
MCC
AutoCAD SHX Text
MOTOR CONTROL CENTER
AutoCAD SHX Text
MFR
AutoCAD SHX Text
MANUFACTURER
AutoCAD SHX Text
MH
AutoCAD SHX Text
MANHOLE
AutoCAD SHX Text
MIN
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
MO
AutoCAD SHX Text
MOTOR OIL
AutoCAD SHX Text
MOD
AutoCAD SHX Text
MODULATING
AutoCAD SHX Text
MPR
AutoCAD SHX Text
MEDIUM PRESSURE RETURN
AutoCAD SHX Text
MPS
AutoCAD SHX Text
MEDIUM PRESSURE STEAM
AutoCAD SHX Text N/A
AutoCAD SHX Text
NOT APPLICABLE
AutoCAD SHX Text
NC
AutoCAD SHX Text
NORMALLY CLOSED / NOISE CRITERIA
AutoCAD SHX Text
NG
AutoCAD SHX Text
NATURAL GAS
AutoCAD SHX Text
NIC
AutoCAD SHX Text
NOT IN CONTRACT
AutoCAD SHX Text
NO
AutoCAD SHX Text
NORMALLY OPEN
AutoCAD SHX Text
NPW
AutoCAD SHX Text
NON-POTABLE WATER
AutoCAD SHX Text
NTS
AutoCAD SHX Text
NOT TO SCALE
AutoCAD SHX Text
OA
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
OVH
AutoCAD SHX Text
OVERHEAD
AutoCAD SHX Text
PC
AutoCAD SHX Text
PLUMBING CONTRACTOR
AutoCAD SHX Text
PCR
AutoCAD SHX Text
PUMPED CONDENSATE RETURN
AutoCAD SHX Text
PD
AutoCAD SHX Text
PRESSURE DROP
AutoCAD SHX Text
PIP
AutoCAD SHX Text
PRE-INSULATED PIPE
AutoCAD SHX Text
PRS
AutoCAD SHX Text
PRESSURE REDUCING STATION
AutoCAD SHX Text
PRV
AutoCAD SHX Text
PRESSURE REDUCING VALVE
AutoCAD SHX Text
ABV
AutoCAD SHX Text
ABOVE
AutoCAD SHX Text
ACCU
AutoCAD SHX Text
AIR COOLED CONDENSING UNIT
AutoCAD SHX Text
AC
AutoCAD SHX Text
AIR CONDITIONING UNIT
AutoCAD SHX Text
AD
AutoCAD SHX Text
ACCESS DOOR
AutoCAD SHX Text
AF
AutoCAD SHX Text
ANTI-FREEZE
AutoCAD SHX Text
AFF
AutoCAD SHX Text
ABOVE FINISHED FLOOR
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AIR HANDLING UNIT
AutoCAD SHX Text
APD
AutoCAD SHX Text
AIR PRESSURE DROP
AutoCAD SHX Text
APPROX
AutoCAD SHX Text
APPROXIMATE
AutoCAD SHX Text
AST
AutoCAD SHX Text
ABOVE GROUND STORAGE TANK
AutoCAD SHX Text
ATC
AutoCAD SHX Text
AUTOMATIC TEMPERATURE CONTROL
AutoCAD SHX Text
ATF
AutoCAD SHX Text
AUTOMATIC TRANSMISSION FLUID
AutoCAD SHX Text
AUTO
AutoCAD SHX Text
AUTOMATIC
AutoCAD SHX Text
AVG
AutoCAD SHX Text
AVERAGE
AutoCAD SHX Text
BBD
AutoCAD SHX Text
BOILER BLOW DOWN
AutoCAD SHX Text
BFP
AutoCAD SHX Text
BACKFLOW PREVENTER
AutoCAD SHX Text
BTU
AutoCAD SHX Text
BRITISH THERMAL UNITS
AutoCAD SHX Text
BTUH
AutoCAD SHX Text
BRITISH THERMAL UNITS PER HOUR
AutoCAD SHX Text C
AutoCAD SHX Text
CONVERTER
AutoCAD SHX Text
CA
AutoCAD SHX Text
COMPRESSED AIR
AutoCAD SHX Text
CD
AutoCAD SHX Text
CEILING DIFFUSER
AutoCAD SHX Text
CFM
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
CI
AutoCAD SHX Text
CAST IRON
AutoCAD SHX Text
CLG
AutoCAD SHX Text
CEILING OR COOLING
AutoCAD SHX Text
CO
AutoCAD SHX Text
CLEANOUT OR CARBON MONOXIDE
AutoCAD SHX Text
CONC
AutoCAD SHX Text
CONCRETE
AutoCAD SHX Text
CONN
AutoCAD SHX Text
CONNECTION
AutoCAD SHX Text
CONTD
AutoCAD SHX Text
CONTINUED
AutoCAD SHX Text
COR
AutoCAD SHX Text
CONTRACTING OFFICER
AutoCAD SHX Text
CUH
AutoCAD SHX Text
CABINET UNIT HEATER
AutoCAD SHX Text
CW
AutoCAD SHX Text
COLD WATER
AutoCAD SHX Text
CHR
AutoCAD SHX Text
CHILLED WATER RETURN
AutoCAD SHX Text
CHS
AutoCAD SHX Text
CHILLED WATER SUPPLY
AutoCAD SHX Text dB
AutoCAD SHX Text
DECIBEL
AutoCAD SHX Text
DCW
AutoCAD SHX Text
DOMESTIC COLD WATER
AutoCAD SHX Text
DDC
AutoCAD SHX Text
DIRECT DIGITAL CONTROL
AutoCAD SHX Text
DHW
AutoCAD SHX Text
DOMESTIC HOT WATER
AutoCAD SHX Text
DHWR
AutoCAD SHX Text
DOMESTIC HOT WATER RETURN
AutoCAD SHX Text
DIA
AutoCAD SHX Text
DIAMETER
AutoCAD SHX Text
DL
AutoCAD SHX Text
DOOR LOUVER
AutoCAD SHX Text
DN
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
DSS
AutoCAD SHX Text
DUCTLESS SPLIT SYSTEM
AutoCAD SHX Text
DX
AutoCAD SHX Text
DIRECT EXPANSION
AutoCAD SHX Text
EA
AutoCAD SHX Text
EXHAUST AIR
AutoCAD SHX Text
EAT
AutoCAD SHX Text
ENTERING AIR TEMPERATURE
AutoCAD SHX Text
EDB
AutoCAD SHX Text
ENTERING DRY BULB TEMPERATURE
AutoCAD SHX Text
EF
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
EG
AutoCAD SHX Text
EXHAUST GRILLE
AutoCAD SHX Text
EL
AutoCAD SHX Text
ELEVATION
AutoCAD SHX Text
ER
AutoCAD SHX Text
EXHAUST REGISTER
AutoCAD SHX Text
ESP
AutoCAD SHX Text
EXTERNAL STATIC PRESSURE
AutoCAD SHX Text
EUH
AutoCAD SHX Text
ELECTRIC UNIT HEATER
AutoCAD SHX Text
EWB
AutoCAD SHX Text
ENTERING WET BULB TEMPERATURE
AutoCAD SHX Text
EWC
AutoCAD SHX Text
ELECTRIC WATER COOLER
AutoCAD SHX Text
EWT
AutoCAD SHX Text
ENTERING WATER TEMPERATURE
AutoCAD SHX Text
EXIST
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
FC
AutoCAD SHX Text
FLEXIBLE CONNECTION
AutoCAD SHX Text
FCO
AutoCAD SHX Text
FLOOR CLEANOUT
AutoCAD SHX Text
FD
AutoCAD SHX Text
FIRE DAMPER OR FLOOR DRAIN
AutoCAD SHX Text
FLA
AutoCAD SHX Text
FULL LOAD AMPS
AutoCAD SHX Text
FLR
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
FLTK
AutoCAD SHX Text
FLASH TANK
AutoCAD SHX Text
FO
AutoCAD SHX Text
FLAT OVAL
AutoCAD SHX Text
FOB
AutoCAD SHX Text
FLAT ON BOTTOM
AutoCAD SHX Text
FOR
AutoCAD SHX Text
FUEL OIL RETURN
AutoCAD SHX Text
FACILITY MANAGEMENT SYSTEM (HVAC)
AutoCAD SHX Text
FMS
AutoCAD SHX Text
INDUSTRIAL EXHAUST REGISTER
AutoCAD SHX Text
IER
AutoCAD SHX Text
TEMPERED WATER
AutoCAD SHX Text
TW
AutoCAD SHX Text
XX
AutoCAD SHX Text
NUMERICAL VALUE VARIABLE
AutoCAD SHX Text
DISC
AutoCAD SHX Text
DISCONNECT
AutoCAD SHX Text
SW
AutoCAD SHX Text
SWITCH
AutoCAD SHX Text
HLS
AutoCAD SHX Text
HIGH/LOW DUCT SPLIT
AutoCAD SHX Text
INFO
AutoCAD SHX Text
INFORMATION
AutoCAD SHX Text
IN WC
AutoCAD SHX Text
INCHES IN WATER COLUMN
AutoCAD SHX Text (X)
AutoCAD SHX Text
REMOVE, DEMOLISH
AutoCAD SHX Text
AA
AutoCAD SHX Text
ALPHANUMERICAL VALUE VARIABLE
AutoCAD SHX Text
2-POS
AutoCAD SHX Text
TWO POSITION
AutoCAD SHX Text
ET
AutoCAD SHX Text
EXPANSION TANK
AutoCAD SHX Text
HPS
AutoCAD SHX Text
HIGH PRESSURE STEAM
AutoCAD SHX Text
DB
AutoCAD SHX Text
DRY BULB
AutoCAD SHX Text
CR
AutoCAD SHX Text
CEILING RETURN
AutoCAD SHX Text
HVAC
AutoCAD SHX Text
HEATING, VENTILATING & AIR CONDITIONING
AutoCAD SHX Text (S)
AutoCAD SHX Text
SECONDARY
AutoCAD SHX Text
HPC
AutoCAD SHX Text
HIGH PRESSURE CONDENSATE
AutoCAD SHX Text
BDD
AutoCAD SHX Text
BACKDRAFT DAMPER
AutoCAD SHX Text
ETR, (E)
AutoCAD SHX Text
EXISTING TO REMAIN
AutoCAD SHX Text
MV
AutoCAD SHX Text
MANUAL VENT
AutoCAD SHX Text
AFM
AutoCAD SHX Text
AIR FLOW MEASURING STATION
AutoCAD SHX Text
MCA
AutoCAD SHX Text
MINIMUM CIRCUIT AMPS
AutoCAD SHX Text
MOCP
AutoCAD SHX Text
MAXIMUM OVER CURRENT PROTECTION
AutoCAD SHX Text
OC
AutoCAD SHX Text
OFF CENTER
AutoCAD SHX Text
VEF
AutoCAD SHX Text
VENTILATED EXHAUST FAN
AutoCAD SHX Text
VSF
AutoCAD SHX Text
VENTILATED SUPPLY FAN
AutoCAD SHX Text
ID
AutoCAD SHX Text
INSIDE DIAMETER
AutoCAD SHX Text
HVLS
AutoCAD SHX Text
HIGH VOLUME LOW SPEED
AutoCAD SHX Text
HV
AutoCAD SHX Text
HEATING AND VENTILATING UNIT
AutoCAD SHX Text
OSD
AutoCAD SHX Text
OPEN SITE DRAIN
AutoCAD SHX Text
PSIG
AutoCAD SHX Text
POUNDS PER SQUARE INCH GAUGE
AutoCAD SHX Text
STM
AutoCAD SHX Text
STEAM
AutoCAD SHX Text
SAR
AutoCAD SHX Text
SUPPLY AIR REGISTER
AutoCAD SHX Text
WTR
AutoCAD SHX Text
WATER
AutoCAD SHX Text
REFRIGERANT PIPING RETURN
AutoCAD SHX Text
RL
AutoCAD SHX Text
REFRIGERANT PIPING SUPPLY
AutoCAD SHX Text
RS
AutoCAD SHX Text
CONDENSATE DRAIN
AutoCAD SHX Text
CD
AutoCAD SHX Text
EXISTING TO BE REMOVED
AutoCAD SHX Text
SD
AutoCAD SHX Text
IN THERMOWELL
AutoCAD SHX Text
XR
AutoCAD SHX Text
REMOVE & RELOCATE
AutoCAD SHX Text
EMCS
AutoCAD SHX Text
ENERGY MGMT & CONTROL SYSTEM
AutoCAD SHX Text
INDICATED
AutoCAD SHX Text
(HEAVY DASHED LINE)
AutoCAD SHX Text
(HEAVY DASHED LINE)
AutoCAD SHX Text
(E)XX-#
AutoCAD SHX Text
(X)XX-#
AutoCAD SHX Text
EXISTING ELEMENTS TO REMAIN
AutoCAD SHX Text
(THIN LINE)
AutoCAD SHX Text
(HEAVY DASHED LINE)
AutoCAD SHX Text
TEMPERATURE PRESSURE FITTING
AutoCAD SHX Text
(PETE'S PLUG)
AutoCAD SHX Text PIPING SHALL BE FIELD ROUTED IN ACCORDANCE WITH APPROPRIATE ENGINEERING PRACTICES, INDUSTRY STANDARDS, AND GOVERNING CODES/REGULATIONS. ROUTE OF PIPE, INCLUDING CLEARANCE, IS THE RESPONSIBILITY OF THE CONTRACTOR. UNIONS, BUSHINGS, AND REDUCING INSERTS, NOT SHOWN ON THE DRAWINGS, BUT REQUIRED FOR INSTALLATION SHALL BE PROVIDED. INDICATED EXISTING CONDITIONS (E.G. SIZE/LOCATION OF PIPING, DUCTWORK, EQUIPMENT, AND BUILDING ELEMENTS) ARE BASED ON INFORMATION OBTAINED FROM AVAILABLE RECORD DRAWINGS AND/OR FIELD SURVEYS. EXISTING CONDITIONS NOT RELATED TO THE WORK MAY NOT BE SHOWN. EXISTING CONDITIONS ARE PROVIDED FOR THE CONVENIENCE OF THE CONTRACTOR ONLY AND ARE NOT GUARANTEED TO BE COMPLETE OR CORRECT. PLANNING AND CHECKING HAS BEEN DONE BY THE ENGINEER TO MINIMIZE INTERFERENCES. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL FIELD VERIFY LOCATION AND SIZES OF ELEMENTS RELATED TO THE WORK. ROUTING OF PIPING AND DUCTWORK SHOWN ON DRAWINGS IS DIAGRAMMATIC. CONTRACTOR SHALL ASCERTAIN THAT INTERFERENCES WILL NOT BE ENCOUNTERED, PREVENTING THE DISASSEMBLY OF PARTIALLY OR COMPLETELY ERECTED SYSTEMS FOR RE-ROUTING TO CLEAR OBSTRUCTIONS WHICH MAY EXIST. EXISTING VALVES SHALL NOT BE ASSUMED TO PROVIDE POSITIVE SHUT-OFF. COORDINATE REQUIRED OPERATION OF VALVES WITH GOVERNMENT PERSONNEL. VALVES REQUIRED FOR SYSTEM ISOLATION SHALL BE TESTED PRIOR TO THE WORK SUCH THAT PROPER PLANNING AND WORK SEQUENCING CAN BE PERFORMED. COORDINATE VALVE TESTING WITH CONTRACTING OFFICER. IMMEDIATELY NOTIFY CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE OF VALVES THAT FAIL TO PROVIDE POSITIVE SHUT-OFF. CONTRACTOR SHALL PROVIDE LOW POINT HOSE END PIPE DRAINS WITH CAPS AS REQUIRED TO COMPLETELY DRAIN SYSTEMS INSTALLED UNDER THIS WORK. PROVIDE MANUAL AIR VENTS WITH CAPS AT HIGH POINTS IN SYSTEMS INSTALLED UNDER THIS WORK. PROVIDE AN EMERGENCY SHUTOFF SWITCH IN THE HVAC CONTROL SYSTEM TO IMMEDIATELY SHUT DOWN THE AIR DISTRIBUTION AND EXHAUST SYSTEMS IN THE BUILDING AND CLOSE ALL DAMPERS LEADING TO THE OUTSIDE.
AutoCAD SHX Text
GENERAL MECHANICAL NOTES
AutoCAD SHX Text REMOVE HANGERS, SUPPORTS, ANCHORS AND GUIDES, MISCELLANEOUS STRUCTURAL STEEL, CONTROLS AND INSTRUMENTATION, CONTROL WIRES AND TUBING, SPECIALTIES, VENTS AND DRAINS, ELECTRICAL POWER, AND OTHER ASSOCIATED ACCESSORIES IN THE PROCESS OF PIPE, DUCTWORK, AND EQUIPMENT DEMOLITION. SUPPORTS FOR PIPE, DUCTWORK AND SYSTEMS SHOWN OR NOTED TO BE DEMOLISHED THAT PENETRATE THROUGH THE INTERIOR ROOF INSULATION SHALL BE CUT 3" ABOVE INSULATION AND COVERED WITH A PROTECTIVE PLASTIC CAP (BRIGHT ORANGE). EXISTING PIPING, DUCTWORK AND SYSTEMS SHOWN OR NOTED TO BE DEMOLISHED SHALL BE DISCONNECTED AND REMOVED BACK TO SERVICE MAINS, UNLESS OTHERWISE INDICATED. EXISTING PIPING, DUCTWORK AND SYSTEMS SHOWN TO REMAIN IN PLACE SHALL BE CAPPED, PLUGGED, BLIND FLANGED OR OTHERWISE SEALED. NO PIPING OR DUCTWORK SHALL BE LEFT OPEN ENDED UNLESS OTHERWISE INDICATED. BEFORE DISCONNECTING PIPING, VERIFY THAT PIPING HAS BEEN ISOLATED, VENTED, AND DRAINED. REMOVE ALL FLUIDS AND GASES CONTAINED WITHIN PIPING, TANKS, AND EQUIPMENT SHOWN OR NOTED TO BE DEMOLISHED. NO FLUIDS SHALL BE ALLOWED TO DRAIN TO THE BUILDING SANITARY OR STORM SYSTEM WITHOUT WRITTEN APPROVAL FROM THE CONTRACTING OFFICER. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONTAIN, HAUL, AND LEGALLY DISPOSE OF REMOVED FLUIDS AND GASES OFFSITE. DEMOLITION SHOWN IS BASED ON AS-BUILT DRAWINGS AND FIELD INVESTIGATION TO THE EXTENT POSSIBLE. FIELD VERIFY EXACT ROUTING OF PIPING AND DUCTWORK PRIOR TO COMMENCEMENT OF WORK. PATCH AND SEAL WALL AND FLOOR OPENINGS WHERE PIPING AND DUCTWORK IS REMOVED PER ARCHITECTURAL DETAILS. PROVIDE TEMPORARY CAPS FOR OPEN ENDS OF PIPING AND DUCTWORK TO REMAIN UNTIL NEW CONNECTIONS ARE MADE.
AutoCAD SHX Text
GENERAL MECHANICAL DEMOLITION NOTES
AutoCAD SHX Text
FLOOR DRAIN
AutoCAD SHX Text
FLOOR SINK
AutoCAD SHX Text
FS
AutoCAD SHX Text
FD
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 1.
AutoCAD SHX Text 2.
AutoCAD SHX Text 3.
AutoCAD SHX Text 4.
AutoCAD SHX Text 5.
AutoCAD SHX Text 5.
AutoCAD SHX Text
HOT WATER SUPPLY
AutoCAD SHX Text
HOT WATER RETURN
AutoCAD SHX Text
HWS
AutoCAD SHX Text
HWR
AutoCAD SHX Text
SUPPLY DUCT UP
AutoCAD SHX Text
SUPPLY DUCT DOWN
AutoCAD SHX Text
RETURN DUCT UP
AutoCAD SHX Text
RETURN DUCT DOWN
AutoCAD SHX Text
EXHAUST DUCT UP
AutoCAD SHX Text
EXHAUST DUCT DOWN
AutoCAD SHX Text
(E) TO REMAIN
AutoCAD SHX Text
DUCTWORK, SINGLE LINE
AutoCAD SHX Text
DEMOLISHED DUCTWORK, SINGLE LINE
AutoCAD SHX Text (E)
AutoCAD SHX Text
EXISTING
AutoCAD SHX Text
(ALL ABBREVIATIONS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
AutoCAD SHX Text
(ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON DRAWINGS)
AutoCAD SHX Text
DTR
AutoCAD SHX Text
DUCT THRU ROOF
AutoCAD SHX Text
DN
AutoCAD SHX Text
DOWN
AutoCAD SHX Text
UNO
UNLESS NOTED OTHERWISE
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
MD100
GENERAL NOTES
1/8" = 1'-0"
A1 MECHANICAL PARTIAL FLOOR PLAN DEMOLITION
N
MD100
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
F
L O
A
N
D
E M
O L
I T
I O
N
KEYED NOTES
6 6
KEYPLAN
N O
N O
R H
U
9 9
AutoCAD SHX Text
AutoCAD SHX Text
SUPPLY WAREHOUSE
AutoCAD SHX Text
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
VENDING
AutoCAD SHX Text
AutoCAD SHX Text
SUPPLY OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
NBC ROOM
AutoCAD SHX Text
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 127A
AutoCAD SHX Text
JANITOR CLOSET
AutoCAD SHX Text
AutoCAD SHX Text
PASSAGE
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN'S LATRINE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
ENTRANCE LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
MATCH LINE, SEE SHEET MD101
AutoCAD SHX Text REMOVE EXHAUST FAN CONTROL PANEL. EXISTING LOUVER TO REMAIN. REMOVE CONNECTED DUCTWORK. REMOVE HOT WATER PIPING AND HANGERS (TYP). REMOVE TERMINAL UNIT AND ASSOCIATED WIRING, CONTROLS, PIPING AND DUCTWORK. REMOVE EXHAUST FAN ON ROOF. CURB TO REMAIN FOR REUSE. PROVIDE WATER-TIGHT SEAL OVER OPENING. REMOVE DASHED DUCTWORK AND ALL CONNECTED AIR DEVICES. REMOVE FAN COIL. REMOVE SIDEWALL PROPELLER FAN AND HOUSING. ROOF OPENING TO GRAVITY VENTILATOR TO REMAIN. REMOVE FIRE DAMPERS (TYP).
AutoCAD SHX Text
1. 2.
AutoCAD SHX Text B1
AutoCAD SHX Text M-401
PATCH AND PAINT WALLS AND CEILINGS TO MATCHING EXISTING WHERE EQUIPMENT, DUCTS, PIPING, CONDUIT, AND WIRING IS NOT REPLACED IN KIND. REFER TO ARCHITECTURAL DRAWINGS. APPROXIMATE ELEVATIONS (AFF) IN HIGH BAY ROOMS (104, 105, 107, 108, 109: PROPELLER FANS: 25 FEET
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
MD101
1/8" = 1'-0"
A1 MECHANICAL PARTIAL FLOOR PLAN DEMOLITION
MD101
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
F
L O
A
N
D
E M
O L
I T
I O
N
N
3 3
KEYPLAN
GENERAL NOTES
KEYED NOTES
4 4 4
5 5
5 5
N O
N O
R H
U
6 6
7 7
AutoCAD SHX Text M
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
NBC ROOM
AutoCAD SHX Text
AutoCAD SHX Text
UNIT STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
VAULT OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
ARMS VAULT
AutoCAD SHX Text
760 SF
AutoCAD SHX Text
AutoCAD SHX Text
ASSEMBLY ROOM
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
PASSAGE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
SECOND ENTRANCE
AutoCAD SHX Text
AutoCAD SHX Text
HALLWAY
AutoCAD SHX Text
OHD
AutoCAD SHX Text
OHD
AutoCAD SHX Text
BOL
AutoCAD SHX Text
BOL
AutoCAD SHX Text
AutoCAD SHX Text
OHD
AutoCAD SHX Text
OHD
AutoCAD SHX Text
MATCH LINE, SEE SHEET MD100
AutoCAD SHX Text REMOVE HOT WATER PIPING AND HANGERS (TYP). REMOVE TERMINAL UNIT AND ASSOCIATED WIRING, CONTROLS, PIPING AND DUCTWORK. REMOVE DASHED DUCTWORK AND CONNECTED AIR DEVICES (TYP). INFRARED HEATER TO REMAIN. REMOVE SIDEWALL PROPELLER FAN AND HOUSING. REMOVE ABANDONED INLINE FAN, CONTROLS, AND DUCTWORK. SEAL OA OPENINGS WITH INSULATED SHEET METAL PANEL PER ARCHITECTURAL DWGS. ROOF OPENING TO GRAVITY VENTILATOR TO REMAIN. PORTABLE HUMIDIFIER AND DRAIN TO REMAIN. REMOVE MOTORIZED DAMPER AND CONTROLS. LOUVER TO REMAIN. REMOVE FIRE DAMPERS (TYP).
AutoCAD SHX Text
1. 2.
PATCH AND PAINT WALLS AND CEILINGS TO MATCHING EXISTING WHERE EQUIPMENT, DUCTS, PIPING, CONDUIT, AND WIRING IS NOT REPLACED IN KIND. REFER TO ARCHITECTURAL DRAWINGS. APPROXIMATE ELEVATIONS (AFF) IN HIGH BAY ROOMS (104, 105, 107, 108, 109: PROPELLER FANS: 25 FEET
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
MD130
GENERAL NOTES
1/8" = 1'-0"
A1 MECHANICAL PARTIAL ROOF PLAN DEMOLITION
N
MD130
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
R
O O
F
P
L A
N
D
E M
O L
I T
I O
N
KEYED NOTES
KEYPLAN
N O
N O
R H
U
2 23
AutoCAD SHX Text
MATCH LINE, SEE SHEET MD131
AutoCAD SHX Text REMOVE EXHAUST FAN. CURB TO REMAIN FOR REUSE. GRAVITY VENT TO REMAIN. OA DUCT GOOSENECK TO REMAIN. BOILER COMBINED FLUE/OA INTAKE VENT TO REMAIN.
AutoCAD SHX Text
USE FIGURED DIMENSIONS ONLY. DO NOT SCALE DRAWINGS.
1.
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
MD131
1/8" = 1'-0"
A1 MECHANICAL PARTIAL ROOF PLAN DEMOLITION
MD131
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
R
O O
F
P
L A
N
D
E M
O L
I T
I O
N
N
KEYPLAN
GENERAL NOTES
KEYED NOTES
N O
N O
R H
U
AutoCAD SHX Text
MATCH LINE, SEE SHEET MD130
AutoCAD SHX Text
GRAVITY VENT TO REMAIN.
AutoCAD SHX Text
USE FIGURED DIMENSIONS ONLY. DO NOT SCALE DRAWINGS.
1.
R
H W
R H
W R
H W
R H
W R
HWR HWR HWR HWR
C W
S
H W
R
HWR
HWR
H W
R H
W R
H W
R
C W
R
CWR
U
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-100
1/8" = 1'-0"
A1 MECHANICAL PARTIAL FLOOR PLAN
M-100
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
F
L O
KEYPLAN
GENERAL NOTES
KEYED NOTES
D A
B
L V
T
R H
U
AutoCAD SHX Text 8x8
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
CD-1 400
AutoCAD SHX Text
CD-1 400
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
CD-1 420
AutoCAD SHX Text
CD-1 420
AutoCAD SHX Text
CD-1 420
AutoCAD SHX Text
CD-1 420
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
CD-1 230 TYP 8
AutoCAD SHX Text
CD-1 220
AutoCAD SHX Text
CD-1 310
AutoCAD SHX Text
ER-1 260
AutoCAD SHX Text
ER-1 970
AutoCAD SHX Text
ER-1 375
AutoCAD SHX Text
AutoCAD SHX Text
ER-1 220
AutoCAD SHX Text
SW
AutoCAD SHX Text 30x24
AutoCAD SHX Text 38x24
AutoCAD SHX Text 24x24
AutoCAD SHX Text
CR-1 420
AutoCAD SHX Text
CR-1 825
AutoCAD SHX Text
CR-1 825
AutoCAD SHX Text
CR-1 825
AutoCAD SHX Text
CR-1 825
AutoCAD SHX Text 30x24
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text 16x12
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text 10x12
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text 16x12
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text 10x12
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text
CD-1 275
AutoCAD SHX Text 16x16
AutoCAD SHX Text T
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text 16x16
AutoCAD SHX Text 16x16
AutoCAD SHX Text
VD
AutoCAD SHX Text 16x16
AutoCAD SHX Text
CUH
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
CD-1 350
AutoCAD SHX Text
CD-1 350
AutoCAD SHX Text
VD
AutoCAD SHX Text
CR-1 700
AutoCAD SHX Text
CR-1 800
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text 18x16
AutoCAD SHX Text
AutoCAD SHX Text 12x14
AutoCAD SHX Text 16x16
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text 12x14
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text 8x12
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text 26x24
AutoCAD SHX Text 48x24
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text 14x12
AutoCAD SHX Text
CR-1 350
AutoCAD SHX Text
VD
AutoCAD SHX Text 16x16
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
CD-1 300
AutoCAD SHX Text
CD-1 300
AutoCAD SHX Text
CD-1 350
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
CD-1 410
AutoCAD SHX Text
(E)DL
AutoCAD SHX Text
(E)DL
AutoCAD SHX Text
(E)DL
AutoCAD SHX Text
(E)DL
AutoCAD SHX Text
EF
AutoCAD SHX Text
AutoCAD SHX Text 70x20
AutoCAD SHX Text
RF
AutoCAD SHX Text
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
CR-1 3520
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
ER-1 375
AutoCAD SHX Text
VD
AutoCAD SHX Text 18x16
AutoCAD SHX Text 14x12
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text 22x22
AutoCAD SHX Text 22x22
AutoCAD SHX Text
CR-1 TYP 2
AutoCAD SHX Text
CR-1 TYP 2
AutoCAD SHX Text 24x24
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text 34x24
AutoCAD SHX Text 48x24
AutoCAD SHX Text 48x24
AutoCAD SHX Text 48x24
AutoCAD SHX Text 38x24
AutoCAD SHX Text
CD-1 300
AutoCAD SHX Text
AutoCAD SHX Text
SUPPLY WAREHOUSE
AutoCAD SHX Text
AutoCAD SHX Text
OPEN OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
VENDING
AutoCAD SHX Text
AutoCAD SHX Text
SUPPLY OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
NBC ROOM
AutoCAD SHX Text
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
CLASSROOM
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text 127A
AutoCAD SHX Text
JANITOR CLOSET
AutoCAD SHX Text
AutoCAD SHX Text
PASSAGE
AutoCAD SHX Text
AutoCAD SHX Text
MEN'S SHOWER
AutoCAD SHX Text
AutoCAD SHX Text
WOMEN'S LATRINE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
ENTRANCE LOBBY
AutoCAD SHX Text
AutoCAD SHX Text
OFFICE
AutoCAD SHX Text
MATCH LINE, SEE SHEET M-101
AutoCAD SHX Text INTERIOR WALLS ARE CMU. UTILIZE (E) OPENINGS TO THE FULLEST EXTENT POSSIBLE FOR ROUTING OF NEW DUCTS AND PIPING. HHW BRANCH PIPING TO VAV BOXES AND UNIT HEATERS TO BE 3/4" UNO. APPROXIMATE ELEVATIONS (AFF) IN HIGH BAY ROOMS (104, 105, 107, 108, 109: PROPELLER FANS: 25 FEET
AutoCAD SHX Text
1. 2. 3.
AutoCAD SHX Text B3
AutoCAD SHX Text M-401
AutoCAD SHX Text
AutoCAD SHX Text
(E) INFRARED HEATER (E) ROOF OPENING TO GRAVITY VENTILATOR. PROVIDE SPACE TEMPERATURE SENSOR TO MONITOR AND MAINTAIN SUPPLY WAREHOUSE ROOM 104 TEMPERATURE. PROVIDE SPACE TEMPERATURE SENSOR TO MONITOR AND MAINTAIN STORAGE ROOM 105 TEMPERATURE. INSTALL FAN IN (E) METAL WALL PANEL. MEASURE (E) WALL OPENING PRIOR TO ORDERING EQUIPMENT. INSTALL FAN IN (E) CMU WALL. MEASURE (E) WALL OPENING PRIOR TO ORDERING EQUIPMENT. PROVIDE SA & RA DUCT PLENUMS SAME HEIGHT AND WIDTH AS CUH OPENINGS. BAS PANEL SERVING SUPPLY FANS IN ROOM 104 AND ROOM 105. PROVIDE EMERGENCY AIR DISTRIBUTION SHUTDOWN SWITCH WITH HINGED CLEAR COVER, WARNING SIGN AND TAG. 18x18 EA DTR TO EF-1. MAKE TRANSITION AS REQUIRED TO FIT EF-1. MAKE TRANSITION AS REQUIRED TO FIT . MAKE TRANSITION AS REQUIRED TO FIT (E) CURB DIMENSIONS. CONNECT RELIEF AIR DUCT TO (E) 70x20 LOUVER. VERIFY LOUVER DIMENSIONS. PROVIDE INSULATED BASE FOR THERMOSTAT. MOTORIZED LOW-LEAK RELIEF AIR CONTROL DAMPER.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HWR HWR HWR HWR
W
R
U
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-101
1/8" = 1'-0"
A1 MECHANICAL PARTIAL FLOOR PLAN
M-101
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
F
L O
A
N
KEYPLAN
N
GENERAL NOTES
KEYED NOTES
D A
B
L V
T
R H
U
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 290
AutoCAD SHX Text
CD-1 330
AutoCAD SHX Text
CD-1 330
AutoCAD SHX Text
CD-1 330
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
CD-1 210
AutoCAD SHX Text
CD-1 210
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
CD-1 300
AutoCAD SHX Text 14x14
AutoCAD SHX Text 22x22
AutoCAD SHX Text 24x24
AutoCAD SHX Text
CR-1 1160
AutoCAD SHX Text
CR-1 250
AutoCAD SHX Text
CR-1 420
AutoCAD SHX Text 18x18
AutoCAD SHX Text 22x20
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text T
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text 18x16
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text 16x16
AutoCAD SHX Text
CR-1 1160
AutoCAD SHX Text 16x16
AutoCAD SHX Text
CD-1 250
AutoCAD SHX Text
VD
AutoCAD SHX Text
CR-1 990
AutoCAD SHX Text
VD
AutoCAD SHX Text 16x16
AutoCAD SHX Text
CUH
AutoCAD SHX Text
AutoCAD SHX Text
VD
AutoCAD SHX Text
VD
AutoCAD SHX Text
EF
AutoCAD SHX Text
AutoCAD SHX Text
CD-1 300
AutoCAD SHX Text
VAV
AutoCAD SHX Text
AutoCAD SHX Text
(E)DL
AutoCAD SHX Text
(E)DL
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text M
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text
SF
AutoCAD SHX Text
AutoCAD SHX Text
EF
AutoCAD SHX Text
AutoCAD SHX Text
SPS
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
UNIT STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
VAULT OFFICE
AutoCAD SHX Text
AutoCAD SHX Text
ARMS VAULT
AutoCAD SHX Text
AutoCAD SHX Text
ASSEMBLY ROOM
AutoCAD SHX Text
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
AutoCAD SHX Text
PASSAGE
AutoCAD SHX Text
AutoCAD SHX Text
VESTIBULE
AutoCAD SHX Text
AutoCAD SHX Text
SECOND ENTRANCE
AutoCAD SHX Text
AutoCAD SHX Text
HALLWAY
AutoCAD SHX Text
AutoCAD SHX Text
MATCH LINE, SEE SHEET M-100
AutoCAD SHX Text
1. 2. 3.
AutoCAD SHX Text
AutoCAD SHX Text
(E) INFRARED HEATER (E) ROOF OPENING TO GRAVITY VENTILATOR. ROOF OPENING TO GRAVITY VENTILATOR. (E) PORTABLE HUMIDIFIER AND DRAIN. PROVIDE MOTORIZED DAMPER FOR (E) OA LOUVER. PROVIDE AHU-1 STATIC PRESSURE SENSOR. AHU-1 STATIC PRESSURE SENSOR. STATIC PRESSURE SENSOR. INSTALL FAN IN (E) METAL WALL PANEL. MEASURE (E) WALL OPENING PRIOR TO ORDERING EQUIPMENT. INSTALL FAN IN (E) CMU WALL. MEASURE (E) WALL OPENING PRIOR TO ORDERING EQUIPMENT. PROVIDE SA & RA DUCT PLENUMS SAME HEIGHT AND WIDTH AS CUH OPENINGS.
AutoCAD SHX Text INTERIOR WALLS ARE CMU. UTILIZE (E) OPENINGS TO THE FULLEST EXTENT POSSIBLE FOR ROUTING OF NEW DUCTS AND PIPING. HHW BRANCH PIPING TO VAV BOXES AND UNIT HEATERS TO BE 3/4" UNO. APPROXIMATE ELEVATIONS (AFF) IN HIGH BAY ROOMS (104, 105, 107, 108, 109: PROPELLER FANS: 25 FEET
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-130
1/8" = 1'-0"
A1 MECHANICAL PARTIAL ROOF PLAN
M-130
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
R
O O
F
P
L
KEYPLAN
GENERAL NOTES
KEYED NOTES
D A
B
L V
T
R H
U
AutoCAD SHX Text
EF
AutoCAD SHX Text
AutoCAD SHX Text
MATCH LINE, SEE SHEET M-131
AutoCAD SHX Text
AutoCAD SHX Text MOUNT EF AND NEW CURB ADAPTER ON (E) ROOF CURB. (E) GRAVITY VENT (E) OA DUCT GOOSENECK (E) BOILER COMBINED FLUE/OA INTAKE
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-131
1/8" = 1'-0"
A1 MECHANICAL PARTIAL ROOF PLAN
M-131
1/8" = 1'-0"
24'4' 8' 16'
M E
C H
A N
I C
R
T I A
L
R
O O
F
P
L A
N
KEYPLAN
N
GENERAL NOTES
KEYED NOTES
D A
B
L V
T
R H
U
AutoCAD SHX Text
MATCH LINE, SEE SHEET M-130
AutoCAD SHX Text
AutoCAD SHX Text
(E) GRAVITY VENT
AutoCAD SHX Text
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-401
1/4" = 1'-0"
B1 MECHANICAL ROOM DEMOLITION FLOOR PLAN
M-401
1/4" = 1'-0"
12'2' 4' 8'
M E
C H
A N
I C
L
A R
G E
D
P
L A
1/4" = 1'-0"
B3 MECHANICAL ROOM FLOOR PLAN
M-401
KEYED DEMOLITION NOTES
KEYPLAN
MD-100 M-100
KEYED NEW WORK NOTES
N
GENERAL NOTES
N O
N O
R H
U
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text T
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text REMOVE DASHED HYDRONIC PIPING (TYP). REMOVE DASHED DUCTWORK (TYP). (E) BOILER VENT AND FLUE DUCTING TO REMAIN. REMOVE DUCTWORK LEADING TO EXISTING ROOF PENETRATION. GOOSENECK ON ROOF TO REMAIN. (E) DOMESTIC HOT WATER HEATER, STORAGE TANK, PIPING AND ACCESSORIES TO REMAIN. REMOVE AIR HANDLING UNIT AND ASSOCIATED DUCTWORK, PIPING, ACCESSORIES AND CONTROLS. HOUSEKEEPING PAD TO REMAIN. REMOVE PUMPS AND ASSOCIATED PIPING, ACCESSORIES AND CONTROLS. HOUSEKEEPING PAD TO REMAIN. (E) BOILER, VENTING AND OA DUCT TO REMAIN. PROVIDE BACNET CARD FOR COMMUNICATION WITH NEW BAS. (E) CHILLER TO REMAIN. PROVIDE BACNET CARD FOR COMMUNICATION WITH NEW BAS. REMOVE EXPANSION TANK AND ASSOCIATED PIPING. REMOVE AIR SEPARATOR TANK AND ASSOCIATED PIPING. REMOVE POT FEEDER AND STAND. REMOVE AIR DRYER. REMOVE DDC CONTROL PANEL. REMOVE SUPPLY FAN VFD'S.
AutoCAD SHX Text BAS PANEL SERVING HOT WATER SYSTEM. PROVIDE EMERGENCY SHUTDOWN SWITCH. WHEN SWITCH IS ACTIVATED, BOILER SHALL BE DISABLED. BAS SHALL MONITOR STATUS OF SWITCH AND STOP HOT WATER PUMP WHEN SWITCH IS ACTIVATED. HOUSEKEEPING PAD PER ARCHITECTURAL DWGS. MINIMUM REQUIRED SERVICE CLEARANCES FOR EQUIPMENT. REFER TO MANUFACTURER'S INSTRUCTIONS. 56x30 OA DTR TO (E) ROOF VENT. MAKE DUCT TRANSITION THRU ROOF AS REQUIRED TO MATCH (E) ROOF PENETRATION SIZE AND MAKE POINT OF CONNECTION AT ROOF VENT. HORIZONTAL EXPANSION TANKS ET-1 AND ET-2 ABOVE ET-1 AND ET-2 ABOVE AND ET-2 ABOVE ET-2 ABOVE ABOVE PUMPS ON (E) PIPE SUPPORT STAND. 36x28 OA DTR TO (E) ROOF VENT. MAKE DUCT TRANSITION THRU ROOF AS REQUIRED TO MATCH (E) ROOF PENETRATION SIZE AND MAKE POINT OF CONNECTION AT ROOF VENT. HEAT TRACE OUTDOOR CHW PIPING. BAS PANEL SERVING CHILLED WATER SYSTEM. BAS PANEL SERVING AHU-1. AHU-1. . PROVIDE 24" HIGH INSULATED OA PLENUM WITH AIR FROM STATION AND CONTROL DAMPER. RETURN AIR CONTROL DAMPER.
AutoCAD SHX Text INTERIOR WALLS ARE CMU. UTILIZE (E) OPENINGS TO THE FULLEST EXTENT POSSIBLE FOR ROUTING OF NEW DUCTS AND PIPING. (E) FLOOR-MOUNTED PIPE SUPPORT STRUCTURE IN MECHANICAL ROOM TO REMAIN FOR REUSE IN SUPPORTING NEW PIPING, AIR SEPARATORS, AND EXPANSION TANKS.
AutoCAD SHX Text
1. 2.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
RF-1 VFD VFD
AutoCAD SHX Text
AutoCAD SHX Text
SF-1 VFD VFD
AutoCAD SHX Text
UH
AutoCAD SHX Text
AutoCAD SHX Text
BT
AutoCAD SHX Text
AutoCAD SHX Text
AS
AutoCAD SHX Text
AutoCAD SHX Text
AS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text
AutoCAD SHX Text P
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
SW
AutoCAD SHX Text
SW
AutoCAD SHX Text
FD
AutoCAD SHX Text
FD
AutoCAD SHX Text
(E) DHW STORAGE TANK
AutoCAD SHX Text
(E) WH
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
(2) OA LOUVERS (HIGH AND LOW) TO REMAIN
AutoCAD SHX Text
(E) OA LOUVERS (HIGH AND LOW)
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
(E) BOILER B-1B-1
AutoCAD SHX Text
(E) CHILLER CH-1CH-1
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 48x24 SA
AutoCAD SHX Text M-402
AutoCAD SHX Text B1
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AutoCAD SHX Text 30x30 OA
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text 48x24 RA
AutoCAD SHX Text
POT FEEDER
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
S
H W
S
U
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-402
1/4" = 1'-0"
B1 MECHANICAL ROOM SECTION
M-402
1/4" = 1'-0"
12'2' 4' 8'
M E
C H
A N
I C
C
T I
GENERAL NOTES
O
N O
R H
U
AutoCAD SHX Text
AHU
AutoCAD SHX Text
AutoCAD SHX Text
BT
AutoCAD SHX Text
AutoCAD SHX Text
HWP
AutoCAD SHX Text
AutoCAD SHX Text
CWP
AutoCAD SHX Text
AutoCAD SHX Text
AS
AutoCAD SHX Text
AutoCAD SHX Text 30x30
AutoCAD SHX Text
(E) BOILER
AutoCAD SHX Text
(E) HOT WATER STORAGE TANK
AutoCAD SHX Text
(E) HOT WATER HEATER
AutoCAD SHX Text
AutoCAD SHX Text
MECHANICAL ROOM
AutoCAD SHX Text
3" CHWS TO (E) CHILLER
AutoCAD SHX Text 24x48
AutoCAD SHX Text
POT FEEDER
AutoCAD SHX Text
POT FEEDER
AutoCAD SHX Text
3" CHWR TO (E) CHILLER
AutoCAD SHX Text 24x48 TO OPEN OFFICE 101
AutoCAD SHX Text 36x28
AutoCAD SHX Text
(E) COMBINATION FLUE AND COMBUSTION AIR INTAKE
AutoCAD SHX Text
ET
AutoCAD SHX Text
AutoCAD SHX Text
ET
AutoCAD SHX Text
AutoCAD SHX Text INTERIOR WALLS ARE CMU. UTILIZE (E) OPENINGS TO THE FULLEST EXTENT POSSIBLE FOR ROUTING OF NEW DUCTS AND PIPING. (E) FLOOR-MOUNTED PIPE SUPPORT STRUCTURE IN MECHANICAL ROOM TO REMAIN FOR REUSE IN SUPPORTING NEW PIPING, AIR SEPARATORS, AND EXPANSION TANKS.
1. 2.
M
Y
C
O R
E
N G
I N
E E
R S
P L
A
L E
D R
A W
N
B
Y
A P
P R
O V
D
C
A
B
S I Z
E
D E
S C
R I P
T I O
N
SHEET
IDENTIFICATION
D A
T E
C O
N T
R A
B Y
A R
I T
E
A
L
L I F
E
C
Y C
S
E T
S
F s t
R
S C
F O
C
L E
L L
A N
A
L A
B A
M A
C H
A R
L E
S T
S
T R
I C
T
C H
A R
L E
S T
O N
S
O U
R
O L
I N
A
A
H
A G
O O
D
A
V E
N U
E
C H
A R
L E
S T
O N
S
C
B U
I L
D I N
G
S
T R
O N
G
US Army Corps of Engineers
CHARLESTON DISTRICT
D A
T
H P
D
T A
D
E R
W
H P
F
D E
S I G
N E
D
B
Y
M A
R K
R T
A
S
U B
M I T
T A
L
G
L E
S
U I T
E
A
R L
I N
G T
O N
V
A
J A
C O
G
I N
E E
R I N
G
G
R O
C
T
7-8-19
M-500
M E
C H
A N
I C
T
A I L
S
N O
N O
NTS
C1
FIRE DAMPER WITH FUSIBLE LINK DETAIL
M-500
NTS
C4
TYPICAL DUCT DETAIL
M-500
NTS
A1
TYPICAL PIPE SUPPORT DETAILS
M-500
NTS
C3
TYPICAL DUCTWORK INTERIOR PENETRATION
M-500
NTS
A3
HORIZONTAL UNIT HEATING DETAIL
M-500
NTS
A5
SHOT FEEDER DETAIL
M-500
R H
U
N O
N E
AutoCAD SHX Text NOTES: 1. PACK SPACES BETWEEN OPENING AND DUCT INSULATION WITH MINERAL FIBER CONFORMING WITH ASTM C553. 2. WALL IS INTERIOR AND NOT FIRE RATED
AutoCAD SHX Text
INTERIOR WALL
AutoCAD SHX Text 20 GAGE GALVANIZED STEEL COLLAR (EXPOSED ONLY). SECURE TO WALL ON 6" CENTERS (MINIMUM 4 FASTENERS PER SIDE).
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
1" CLEARANCE (SEE NOTE NO. 1)
AutoCAD SHX Text
20 GAGE GALVANIZED STEEL SLEEVE
AutoCAD SHX Text NOTES: 1. PACK SPACES BETWEEN OPENING AND DUCT INSULATION WITH MINERAL FIBER CONFORMING WITH ASTM C553. 2. WALL IS INTERIOR AND NOT FIRE RATED
AutoCAD SHX Text
INTERIOR WALL
AutoCAD SHX Text 20 GAGE GALVANIZED STEEL COLLAR (EXPOSED ONLY). SECURE TO WALL ON 6" CENTERS (MINIMUM 4 FASTENERS PER SIDE).
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
INSULATION
AutoCAD SHX Text
1" CLEARANCE (SEE NOTE NO. 1)
AutoCAD SHX Text
20 GAGE GALVANIZED STEEL SLEEVE
AutoCAD SHX Text NOTE: PROVIDE FIRE DAMPER FOR ROUND DUCT OR USE TRANSITIONS FOR ROUND TO SQUARE DUCT.
AutoCAD SHX Text
"S" SLIP TYPE WITH SHEET METAL SCREWS
AutoCAD SHX Text
10 GAUGE SLEEVE
AutoCAD SHX Text
SHEET METAL SCREW
AutoCAD SHX Text
NUT OR BOLT OR WELDED
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
1-1/2" X 1-1/2" X 10 GAUGE MINIMUM ANGLE IRON AROUND
AutoCAD SHX Text
6" MAXIMUM
AutoCAD SHX Text
CLEARANCE BETWEEN FIRE DAMPER AND WALL SHALL BE 1/8" PER FOOT OF PERIMETER.
AutoCAD SHX Text
MIN 1" LAP AROUND ENTIRE OPENING
AutoCAD SHX Text
1-1/2" ANGLE
AutoCAD SHX Text
HINGED ACCESS DOOR WITH CAM FASTENER AND NEOPRENE GASKET MINIMUM SIZE 6 X 6
AutoCAD SHX Text NOTE: PROVIDE FIRE DAMPER FOR ROUND DUCT OR USE TRANSITIONS FOR ROUND TO SQUARE DUCT.
AutoCAD SHX Text
"S" SLIP TYPE WITH SHEET METAL SCREWS
AutoCAD SHX Text
10 GAUGE SLEEVE
AutoCAD SHX Text
SHEET METAL SCREW
AutoCAD SHX Text
NUT OR BOLT OR WELDED
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
DUCT
AutoCAD SHX Text
1-1/2" X 1-1/2" X 10 GAUGE MINIMUM ANGLE IRON AROUND
AutoCAD SHX Text
6" MAXIMUM
AutoCAD SHX Text
CLEARANCE BETWEEN FIRE DAMPER AND WALL SHALL BE 1/8" PER FOOT OF PERIMETER.
AutoCAD SHX Text
MIN 1" LAP AROUND ENTIRE OPENING
AutoCAD SHX Text
1-1/2" ANGLE
AutoCAD SHX Text
HINGED ACCESS DOOR WITH CAM FASTENER AND NEOPRENE GASKET MINIMUM SIZE 6 X 6
AutoCAD SHX Text NOTES: 1. DUCT, FITTINGS, MATERIAL AND SUPPORT SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE."
AutoCAD SHX Text RECTANGULAR TO ROUND BRANCH CONNECTIONS SHALL UTILIZE BELL MOUTH TAP FITTINGS. ROUND TO ROUND CONNECTIONS SHALL UTILIZE 45° OVAL TO ROUND TAP FITTINGS.
AutoCAD SHX Text RECTANGULAR TO RECTANGULAR BRANCH CONNECTIONS SHALL UTILIZE 45° ENTRY TAP FITTINGS
AutoCAD SHX Text CONCENTRIC TRANSITION: MAXIMUM ANGLE FOR DIVERGING FLOW = 45°. MAXIMUM ANGLE FOR CONVERGING FLOW = 60°.
AutoCAD SHX Text
ANGLE
AutoCAD SHX Text PROVIDE MANUAL VOLUME DAMPER WITH LOCKING QUADRANT AT ALL BRANCH TAKEOFFS AS REQUIRED TO PROPERLY BALANCE SYSTEM.
AutoCAD SHX Text PROVIDE PROPORTIONAL FITTINGS FOR PARALLEL FLOW BRANCHES. MINIMUM WIDTH SHALL BE 4". PROVIDE VOLUME DAMPER IN EACH BRANCH. DUAL RADIUS ELBOWS ARE OPTIONAL.
AutoCAD SHX Text
ANGLE
AutoCAD SHX Text
ECCENTRIC TRANSITION: MAXIMUM ANGLE = 30°
AutoCAD SHX Text
PROVIDE TURNING VANES IN RECTANGULAR AND MITERED ELBOWS.
AutoCAD SHX Text FLEXIBLE DUCT MAXIMUM LENGTH SHALL NOT EXCEED 5'-0". NO FLEXIBLE DUCT SHALL BE ALLOWED IN RETURN OR EXHAUST SYSTEMS. EXCEPT WHERE INDICATED.
AutoCAD SHX Text
ROUND ELBOWS SHALL BE 1.5 RADIUS UNLESS OTHERWISE NOTED.
AutoCAD SHX Text NOTES: 1. DUCT, FITTINGS, MATERIAL AND SUPPORT SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE."
AutoCAD SHX Text RECTANGULAR TO ROUND BRANCH CONNECTIONS SHALL UTILIZE BELL MOUTH TAP FITTINGS. ROUND TO ROUND CONNECTIONS SHALL UTILIZE 45° OVAL TO ROUND TAP FITTINGS.
AutoCAD SHX Text RECTANGULAR TO…