J-1502000-09__Riverton _Preventative_Maintenance_Program_-_Index _Detail.xls
XLS spreadsheet 85 KB Posted
- Solicitation number
- W912HP-13-R-0024
About this file
Section J Riverton Preventative Maintenance Program Index
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Award_NoticeCharleston_MFR_West_Facilities.pdf | ||
| pd2BB08.pdf | ||
| J-1502000-13__Equip_Inspection _Test_ _Certification_Program.xls | XLS spreadsheet | |
| J-1502000-08__San_Bruno _Preventative_Maintenance_Program_-_Index _Detail.xls | XLS spreadsheet | |
| Section_F.pdf | ||
| Copy_of_Air_Filter_ _Equipment.pdf | ||
| J-1502000-12__Equipment_Update_Report.xls | XLS spreadsheet | |
| Section_M.pdf | ||
| Section_J.pdf | ||
| J-1502000-05__Service_Call_Report.xls | XLS spreadsheet | |
| J-1502000-07__Pico_Rivera _Preventative_Maintenance_Program_-_Index _Detail.xls | XLS spreadsheet | |
| J-1502000-11_Repair_Work_Report.xls | XLS spreadsheet | |
| Section_C.pdf | ||
| Schedule_B _CLINs.xls | XLS spreadsheet | |
| SF_1449.pdf | ||
| J-1502000-10__Preventative_Maintenance_Program_-_Checklist.xls | XLS spreadsheet | |
| J-1502000-06_Pasadena _Preventative_Maintenance_Program_-_Index _Detail.xls | XLS spreadsheet |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Index
| J-1502000-09 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM INDEX | |||||
| MCRC RIVERTON, UTAH | |||||
| (For Manufacturer, model and serial number of equipment see Detail tab) | |||||
| Equipment | Designation | Quantity | Location | Contractor Developed PM Program Checklist Sheet (Note 8) | Frequency of Inspection |
| 1502000 Spec Item 3.2 - HVAC | |||||
| Air Conditioner - Split System | CU-1, CU-2, CU-3 | 3 | Outside (Adj to Mechanical Equip 141) | Semiannual | |
| Air Conditioner-Window | ACW-1 | 1 | LMF, Office | Annual | |
| Air Filter (HVAC) | AF-1 through AF-5 | 5 | See Tab: Detail - Air Filter | Every Other Month | |
| Air Filter (HVAC) | AF-6 | 1 | See Tab: Detail - Air Filter | Every Other Month, during heating season | |
| Air Filter (HVAC) | AF-7 | 1 | See Tab: Detail - Air Filter | Every Other Month, during cooling season | |
| Air Handling Unit | AHU-1, AHU-2 | 2 | AHU-1 (Mechanical), AHU-2 (Assembly Hall) | Semiannual | |
| Boiler (hot water) | B-1 | 1 | Outside (Adj to Mechanical) | Monthly, during heating season | |
| Chiller - Air Cooled | C-1 | 1 | Outside (Adj to Mechanical) | X | As required by manufacturer, except coils shall be cleaned semiannually |
| Fan (duct) | EF-5 | 1 | LMF (roof), serves vehicle exhaust in Maintenance Bay | Semiannual | |
| Fan (roof) | EF-1 through EF-4, EF-9 | 4 | EF-1, EF-2 (serves Men's Toilet), EF-3 (serves Locker Rm 146), EF-4 (serves Women's Tolet 144), EF-9 (serves storage) | Quarterly | |
| Fan (wall) | EF-6, EF-7, EF-8 | 3 | EF-6 (LMF, Battery Rm), EF-7 (HazMat Locker A), EF-8 (HazMat Locker B) | Semiannual | |
| Fan Coil Unit | AH-1, AH-2, AH-3 | 3 | Mechanical Equip 141 | Annual (spring) | |
| Furnace - Gas | FG-1 | 1 | LMF, Mezzanine | Annual (fall) | |
| Heater-Unit, Forced Air, Steam/Water | HUW-1 | 1 | Mechanical Equip 141 | Annual (fall) | |
| Heater-Unit, Infra-red, Gas | HUIG-1 | 1 | LMF, Maintenance Bay | Annual (fall) | |
| System Water-Chilled Water | CW-1 | 1 | Building 2620 | X | Annual (Note 9) |
| System Water-Heating Hot Water | HW-1 | 1 | Building 2620 | X | Annual (Note 9) |
| Terminal-VAV | VAV-1 through VAV-18 | 18 | See VAV Location Tab | Annual | |
| 1502000 Spec Item 3.2 - Electrical Systems | |||||
| Lighting (exterior) | Lighting | Light fixtures attached toall buildings and pole lighting | Quarterly | ||
| Lighting (interior) | Lighting | Building 2620, Building 2600, HazMat Locker A, HazMat Locker B | Quarterly | ||
| Panelboards | PB-A, PB-M, PB-B, PB-C, PB-J, PB-K, PB-LM, PB-A, PB-M1, PB-HazMatA, PB-HazMatB, PB-SCS, PB-VehshedB, PB-C1 | 13 | PB-A, PB-M (Mechanical), PB-B (Janitorial), PB-C (Storae 138), PB-J, PB-K (Mechanical Equip 141), PB-LM (Perimeter, adj to Turret Trainer), PB-A, PB-M1 (LMF, Tool Rm), PB-HazMatA (HazMat Locker A), PB-HazMatB (HazMat Locker B), PB-SCS (Vehicle Shed A), PB-VehshedB, PB-C1 (Vehicle Shed B) | Annual | |
| 1502000 Spec Item 3.2 - Fire Protection | |||||
| Fire Detection and Alarm System | FA-1, FA-2 | 2 | FA-1 (Building 2600, FA-2 (Building 2620) | Annual | |
| Fire Extinguisher (portable)-Monthly Inspection | FE-1 through FE-22 | 22 | FE-1 (Armory), FE-2, FE-3 (Assembly Hall), FE-4 (Business Office), FE-5 (Classroom 140), FE-6 (Communication Repair), FE-7, FE-8, FE-9, FE-10 (Corridor), FE-11 (FATS 139), FE-12 (Foyer/Waiting), FE-13 (Mechanical), FE-14 (Mechanical Equip 141), FE-15 (Security), FE-16 (Storage), FE-17 thru FE-19 (LMF, Maintenance Bay), FE-20 (LMF, Storage), FE-21 (LMF, Tool Rm), FE-22 (Turret Trainer) | Monthly | |
| Fire Extinguisher (portable)-Annual Maintenance | FE-1 through FE-22 | 22 | FE-1 (Armory), FE-2, FE-3 (Assembly Hall), FE-4 (Business Office), FE-5 (Classroom 140), FE-6 (Communication Repair), FE-7, FE-8, FE-9, FE-10 (Corridor), FE-11 (FATS 139), FE-12 (Foyer/Waiting), FE-13 (Mechanical), FE-14 (Mechanical Equip 141), FE-15 (Security), FE-16 (Storage), FE-17 thru FE-19 (LMF, Maintenance Bay), FE-20 (LMF, Storage), FE-21 (LMF, Tool Rm), FE-22 (Turret Trainer) | Annual | |
| Fire Sprinkler - Chemical (dry/wet) | FSD-1, FSD-2 | 2 | FSD-1 (HazMat Locker A), FSD-2 (HazMat Locker B) | Monthly | |
| Fire Sprinkler - Wet Pipe | FSW-1 | 1 | Building 2620 | Annual | |
| 1502000 Spec Item 3.2 - WHE | |||||
| Crane-Overhead Bridge | COB-1 | 1 | LMF, Maintenance Bay | X | As required by the manufacturer |
| 1502000 Spec Item 3.2 - Miscellaneous Equipment | |||||
| Air Compressor | AC-1 | 1 | LMF, Mezzanine | Semiannual | |
| Air Dryer - Refrigerant | ADR-1 | 1 | LMF, Mezzanine | Semiannual | |
| Door-Overhead (motorized) | DR-1 through DR-5 | 5 | DR-1 (Storage), DR-2 (Storage 138), DR-3 thru DR-5 (LMF, Maintenance Bay) | Semiannual | |
| Drinking Fountain | DF-1 | 1 | Corridor | Annual | |
| Emergency Eyewash & Shower | EES-1, EES-2 | 2 | EES-1 (LMF, Maintenance Bay), EES-2 (LMF, Battery Rm) | Monthly | |
| Plumbing Fixtures (by room) | PF-1 through PF-8 | 8 | PF-1 (Break), PF-2 (Janitorial), PF-3 (Medical), PF-4 (Men's Toilet), PF-5 (Women's Toilet), PF-6 (LMF, Battery Rm), PF-7 (LMF, Maintenance Bay), PF-8 (LMF, Toilet) | Semiannual | |
| Pump (hot water) | P-1, P-2 | 2 | Mechanical Room | Annual | |
| Pump (chilled water) | P-3, P-4 | 2 | Mechanical Room | Semiannual | |
| Shutter-Roll-up (manual) | SRM-1 | 1 | Business Office | Semiannual | |
| Water Heater-Gas | WHG-1, WHG-2 | 2 | WGH-1 (Janotorial), WHG-2 (LMF, Mezzanine) | Semiannual | |
| NOTES | |||||
| Note 1 - Equipment listed without a building name/number is located in Administrative building, building 2620 | |||||
| Note 2 - LMF (Building 2600, LAV Maintenance Facility) | |||||
| Note 3 - HazMat Locker A - Adjacent to LMF | |||||
| Note 4 - HazMat Locker B - Adjacent to vehicle shed | |||||
| Note 5 - Vehicle Shed A - Adj to Building 2620 | |||||
| Note 6 - Vehicle Shed B - Adj to Building 2600 | |||||
| Note 7 - HVAC equipment shall be inspected in the spring or fall unless otherwise noted | |||||
| Note 8 - If blank, Government will provide PM Program checklist sheet | |||||
| Note 9 - Shall be treated/tested after repairs/leaks resulting in refilling of the system | |||||
| Note 10 - For quantity of plumbing fixtures see Tab: Plumbing Fixtures |
Page &P of &N
Detail
| J-1502000-09 | |||||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | |||||
| MCRC RIVERTON, UTAH | |||||
| Equipment | Designation | Manufacturer | Model | Serial Number | Remarks |
| 1502000 Spec Item 3.2.1 - HVAC | |||||
| Air Conditioner - Split System | CU-1 | Trane | 2TTA3060A3000AA | 935551A4F | Air cooled |
| Air Conditioner - Split System | CU-2 | Trane | 2TTA3048A000AA | 9324RDH4F | |
| Air Conditioner - Split System | CU-3 | Trane | 2TTA3024A000AA | 9335P9C3F | |
| Air Handling Unit | AHU-1 | Thermal Corp | CLP 241 | 1-8405-00 | Chw coil, Hw coil, VFD motor |
| Air Handling Unit | AHU-2 | McQuay | Chw coil, Hw coil | ||
| Boiler (hot water) | B-1 | Raypak | H7-0753 | 908299892 | Gas |
| Chiller | C-1 | Trane | CGAFC50EARA1000 | C09H02200 | Air cooled |
| Fan-Unit (roof) | EF-1 | Loren Cook | 6CC3B | ||
| Fan-Unit (roof) | EF-2 | Loren Cook | 120C3B | ||
| Fan-Unit (roof) | EF-3 | Carnes | VEEK10…NA20SPC1 | 241703_001 | |
| Fan-Unit (roof) | EF-4 | Carnes | VEEK10…NA20SPC1 | 602005_005 | |
| Fan-Unit (wall) | EF-6 | Centri-Master | PNU135RFF2 | 09C1342-2 | |
| Fan-Unit (roof) | EF-9 | Centri-Master | PNU200RF | 09F1206-5 | |
| Fan Coil Unit | AH-1 | First Co | 48CVX4-6-2RH | DX cooling coil, Hot water heating coil | |
| Fan Coil Unit | AH-2 | First Co | 36CVX4-C-2RH | DX cooling coil, Hot water heating coil | |
| Fan Coil Unit | AH-3 | First Co | 60CVX4-D-2RH | DX cooling coil, Hot water heating coil | |
| Furnace - Gas | F-1 | Bryant | Plus 80 | ||
| Heater-Unit, Forced (Water) | HUW-1 | Sterling | HS-136AS | M00 150830001001 | |
| Heater-Unit, Infra-red, Gas | HUIG | Reflect-O-Ray | |||
| 1502000 Spec Item 3.2.4 - WHE | |||||
| Crane-Overhead Bridge | COB-1 | Crane-Mussell Crane Mfg Hoist-Detroit Hoist and Crane Co | Hoist: 149045 | 3 ton | |
| 1502000 Spec Item 3.2.5 - Miscellaneous Equipment | |||||
| Air Compressor | AC-1 | Quincy | M0T15ST15HP | 5093959 | 15 HP |
| Air Dryer - Refrigerant | ADR-1 | Pioneer Air Systems | ADR50A | 64249B8B26 | |
| Pump (Hot Water) | P-1, P-2 | Taco Inc | CE1508 | 67 GPM, 54 Head Feet, 3 HP | |
| Pump (Chilled Water) | P-3, P-4 | Taco Inc | 7.5 HP | ||
| Water Heater-Gas | WHG-1 | AO Smith | BTH300A 100 | 0931M000140 | Gas, 225 Gal |
| Water Heater-Gas | WHG-2 | AO Smith | FSG 30 242 | GB98-40532B1-K32 | Gas, 30 Gal |
Page &P of &N
Detail-VAV Location
| J-1502000-09 | ||
| PREVENTATIVE MAINTENANCE PROGRAM DETAIL | ||
| VAV LOCATION | ||
| MCRC RIVERTON, UT | ||
| VAV Designation | Location | Space Served |
| VAV-1 | Armory | Armory |
| VAV-2 | Break Room | Break Room |
| VAV-3 | Business Office | Business Office |
| VAV-4 | Classroom 2 | Classroom 2, Classroom 3 |
| VAV-5 | Communication Repair | Communication Repair |
| VAV-6 | Conference | Conference |
| VAV-7 | Conference | Conference |
| VAV-8 | Corridor | Training, Operations |
| VAV-9 | Exam | Exam, Medical Office |
| VAV-10 | Foyer/Waiting | Foyer/Waiting |
| VAV-11 | Locker Room 146 | Locker Room 146 |
| VAV-12 | Medical | Medical |
| VAV-13 | Office 137 | Office 137 |
| VAV-14 | Prior Service Recruiter | Prior Service Recruiter |
| VAV-15 | SSGT's Office | CO's Office, I&I Office, SSGT's Office |
| VAV-16 | Storage | Storage |
| VAV-17 | Supply Office | Supply Office |
| VAV-18 | Women's Toilet 144 | Women's Toilet 144 |
Page &P of &N
Detail - AF
| J-1502000-09 | |||||||||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | |||||||||
| AIR FILTER (HVAC) | |||||||||
| MCRC RIVERTON, UT | |||||||||
| (FILTER SIZE/QUANTITY SHALL BE FIELD VERIFIED BEFORE PURCHASING REPLACEMENT FILTERS) | |||||||||
| DESIGNATION | EQUIPMENT | FILTER 1 | FILTER 2 | FILTER 3 | FILTER 4 | ||||
| SIZE | QUANTITY | SIZE | QUANTITY | SIZE | QUANTITY | SIZE | QUANTITY | ||
| AF-1 | AHU-1 | 20X25X2 | 8 | ||||||
| AF-2 | AHU-2 | 20X25X2 | 8 | ||||||
| AF-3 | AH-1 | 20X20X2 | 1 | ||||||
| AF-4 | AH-2 | 20X20X2 | 1 | ||||||
| AF-5 | AH-3 | 20X20X2 | 1 | ||||||
| AF-6 | FG-1 | ||||||||
| AF-7 | ACW-1 |
Page &P of &N
Detail - PF
| J-1502000-09 | ||
| PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL | ||
| PLUMBING FIXTURE | ||
| MCRC RIVERTON, UT | ||
| FIXTURE | QUANTITY | |
| Sink | 10 | |
| Shower Head | ||
| Toilet | 5 | |
| Urinal | 4 |
Page &P of &N