J-1502000-06_Pasadena _Preventative_Maintenance_Program_-_Index _Detail.xls

XLS spreadsheet 91 KB Posted

Attached to
Marine Force Reserve (MARFORRES), Facility Maintenance, West Region
Solicitation number
W912HP-13-R-0024
Issued by

About this file

Section J Pasedena Preventative Maintenance Program Index

View the file

Other files

File Type Posted
Award_NoticeCharleston_MFR_West_Facilities.pdf PDF
pd2BB08.pdf PDF
J-1502000-13__Equip_Inspection _Test_ _Certification_Program.xls XLS spreadsheet
J-1502000-08__San_Bruno _Preventative_Maintenance_Program_-_Index _Detail.xls XLS spreadsheet
Section_F.pdf PDF
J-1502000-09__Riverton _Preventative_Maintenance_Program_-_Index _Detail.xls XLS spreadsheet
Copy_of_Air_Filter_ _Equipment.pdf PDF
J-1502000-12__Equipment_Update_Report.xls XLS spreadsheet
Section_M.pdf PDF
Section_J.pdf PDF
J-1502000-05__Service_Call_Report.xls XLS spreadsheet
J-1502000-07__Pico_Rivera _Preventative_Maintenance_Program_-_Index _Detail.xls XLS spreadsheet
J-1502000-11_Repair_Work_Report.xls XLS spreadsheet
Section_C.pdf PDF
Schedule_B _CLINs.xls XLS spreadsheet
SF_1449.pdf PDF
J-1502000-10__Preventative_Maintenance_Program_-_Checklist.xls XLS spreadsheet
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Index

J-1502000-06
PREVENTATIVEMAINTENANCE PROGRAM INDEX
MCRC PASADENA, CA
(For Manufacturer, model and serial number of equipment see Detail tab)
EquipmentDesignationQuantityLocationContractor Developed PM Program Checklist Sheet (Note 3)Frequency of Inspection
1502000 Spec Item 3.2 - HVAC
A/C - Package, Computer RoomACPC-11Server Rm 135Semiannual
Air Filter (HVAC)AF-1 through AF-2121See Tab: Detail - Air FilterQuarterly
Air Filter (HVAC)AF-22 through AF-265See Tab: Detail - Air FilterEvery Other Month
BoilerB-11Mech Rm 116Monthly, during heating season
Fan (roof)EF-1 through EF-87RoofQuarterly
Fan (wall)EF-9, EF-102EF-9 (HazMat Locker A), EF-10 (HazMat Locker B)Semiannual
Fan Coil UnitFC-11Training ICOFT 211Annual (spring)
Furnace - Forced Air, GasFG-11RoofAnnual (fall)
Heat Pump - SplitSHP-11RoofSemiannual
Heater-Unit, Forced, Air, WaterUH-12B&G Work Shop 127, Battery Storage 142Annual (fall)
Heater-Unit, Infra Red, GasRH-16Mechanics Bay 129Annual (fall)
Rooftop UnitAC-1, AC-22RoofSemiannual
System Water-Heating Hot WaterHW-11Mech Rm 116XAnnual (Note 4)
Terminal-VAVVAV-1 through VAV-2121For location see Tab: Detail - VAV LocationsAnnual
1502000 Spec Item 3.2 - Electrical Systems
Lighting (exterior)LightingWall packs attached to buildings and pole lightingQuarterly
Lighting (interior)LightingAdministrative Building, HazMat Locker A, HazMat Locker BQuarterly
PanelboardsPB-DPA, PB-L1, PB-MCCA, PB-1PA, PB-1PB, PB-TPP, PB-1PC, PB-2PA, PB-2PD, PB-2PB, PB-2PC, PB-HazMatA, PB-HazMatB13PB-DPA, PB-L1, PB-MCCA, PB-1PA (Elec Rm 118), PB-1PB (Corridor 128), PB-TPP (Server 135), PB-1PC (Corridor 146), PB-2PA, PB-2PD (Corridor 206), PB-2PB (Corridor 228), PB-2PC (Corridor 200), PB-HazMatA (HazMat Locker A), PB-HazMatB (HazMat Locker B)Annual
1502000 Spec Item 3.2 - Fire Protection
Fire Detection and Alarm SystemFA-11Administrative BuildingAnnual
Fire Extinguisher (portable)-Monthly InspectionFE-1 through FE-1212FE-1 (Corridor 104), FE-2 (Mech Rm 116), FE-3 (Elec Rm 118), FE-4 (Corridor (128), FE-5 (Mechanics Bay 129), FE-6, FE-7 (Supply Warehouse 139), FE-8 (Corridor 151), FE-9, FE-10 (Multi-Purpose Room 157), FE-11 (Corridor 206), FE-12 (Corridor 228)Monthly
Fire Extinguisher (portable)-Annual MaintenanceFE-1 through FE-1212FE-1 (Corridor 104), FE-2 (Mech Rm 116), FE-3 (Elec Rm 118), FE-4 (Corridor (128), FE-5 (Mechanics Bay 129), FE-6, FE-7 (Supply Warehouse 139), FE-8 (Corridor 151), FE-9, FE-10 (Multi-Purpose Room 157), FE-11 (Corridor 206), FE-12 (Corridor 228)Annual
Fire HydrantFH-11Adj to south side of buldingAnnual
Fire Sprinkler - Chemical (dry/wet)FSC-1, FSC-22FSC-1 (HazMat Locker A), FSC-2 (HazMat Locker B)Monthly
Fire Sprinkler - Wet PipeFSW-11Administrative BuildingAnnual
1502000 Spec Item 3.2 - WHE
Crane-Gantry (mobile)CG-11Parking lotXAs required by the manufacturer
Crane-Overhead BridgeCOB-11Mechanics Bay 129XAs required by the manufacturer
1502000 Spec Item 3.2 - VTE
Elevator1XAs required by the manufacturer
1502000 Spec Item 3.2 - Miscellaneous Equipment
Air CompressorAC-11Air Compressor Rm 158Semiannual
Air Dryer - RefrigerantADR-11Air Compressor Rm 158Semiannual
Air Filter - Compressed AirAFC-11Air Compressor Rm 158Semiannual
Door-Overhead (manual)DR-1 through DR-77DR-1 (B&G Work Shop 127), DR-2, DRM-3, DRM-4 (Mechanics Bay 129), DR-5 (Supply Warehouse 139), DR-6 (Radio Shop 144), DR-7 (Gym 158)Semiannual
Drinking FountainDF-1, DF-2, DF-3, DF-44DF-1 ,DF-2 (Corridor 109), DF-3,DF-4 (Corridor 228)Annual
Emergency Eyewash & ShowerEES-11Mechanics Bay 129Monthly
Gutters/Down Spouts CleaningG-11Administrative BuildingAnnual
Fire Door/Shutter - Roll Up TypeFS-1 through FS-44FS-1, FS-2 ( Mtg/Mtc/Avg Office 217), FS-3 (Supply Officer 219), FS-4 (Supply Staff 220)Semiannual
Oil Water SeparatorOil Water Separator1Adj to Mechanics Bay 129Semiannual
Plumbing Fixtures (by room)PF-1 through PF-1111PF-1 (Recreation Room 110), PF-2 (Women 111), PF-3 (Men 112), PF-4 (Women's Locker/Shwr Rm 113), PF-5 (Men's Locker/Shwr Rm 114), PF-6 (Janitor Closet 116), PF-7 (Medical Head 205), PF-8 (Corridor 228), PF-9 (Men Head 229), PF-10 (Womens Head 230), PF-11 ( Perimeter of Building)Semiannual
Pump (hot water)P-11Mech Rm 116Annual
Pump (potw)P-21Mech Rm 116Annual
Slide Gate Operator & Entry SystemSGO-11Front gateSemiannual
Water Heater-GasWH-11Mech Rm 116Semiannual
NOTES
Note 1 - SHP-1 linked to FC-1
Note 2 - HVAC equipment shall be inspected in the spring or fall unless otherwise noted
Note 3 - If blank, Government will provide PM Program checklist sheet
Note 4 - Shall be treated/tested after repairs/leaks resulting in refilling of the system
Note 5 - For quantity of plumbing fixtures see Tab: Plumbing Fixtures

Page &P of &N

Detail

J-1502000-06
PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL
MCRC PASADENA, CA
EquipmentDesignationManufacturerModelSerial NumberRemarks
1502000 Spec Item 3.2 - HVAC
A/C - Package, Computer RoomACPC-1Liebert
BoilerB-1RaypackH-752C8174072630 MBH, Natural Gas
Fan (roof)EF-1Loren Cook150ACEBCentrifugal, 2000 CFM, Belt Drive
Fan (roof)EF-2Loren Cook150ACEBCentrifugal, 2000 CFM, Belt Drive
Fan (roof)EF-3Loren Cook120ACRUBCentrifugal, 1000 CFM, Belt Drive
Fan (roof)EF-4Loren Cook100C15DHCentrifugal, 450 CFM, Direct Drive
Fan (roof)EF-5Loren Cook225ACEBCentrifugal, 4300 CFM, Belt Drive
Fan (roof)EF-6Loren Cook100CPVUtility Set, 550 CFM, Belt Drive
Fan (roof)EF-7Loren Cook270CPVUtility Set, 6925 CFM, Belt Drive
Fan (roof)EF-8Loren Cook180CPVUtility Set, 3200 CFM, Belt Drive
Fan Coil UnitFC-1CarrierFB4AN0602000 cfm
Furnace - Forced Air, GasFG-1ModineHFG_75SFRLN10F21013900-0963
Heat Pump - SplitSHP-1Carrier38YCC0605204200E15272
Heater-Unit, Forced, WaterUH-1ModineHS3390139014500-0902
Heater-Unit, Infra Red, GasRH-1SolaronicsK-150 MBH, Natural Gas
Roof Top UnitAC-1TraneSLHFC504BW67D8AD3F010BC00H22880DX cooling coil, Hot water coil, Supply and return fan
Roof Top UnitAC-2TraneSLHFC254BW47D5DD3F010BC00H22881DX cooling coil, Hot water coil, Supply and return fan
VAV-TerminalVAV-1(T-7)Tuttle & BaileyFPC D 370-4Fan, Filter
VAV-TerminalVAV-2, (T-8)Tuttle & BaileyFPC D 380-5Fan, Filter
VAV-TerminalVAV-3 through VAV-6 (T-10)Tuttle & BaileyFPC D 410-6Fan, Filter
VAV-TerminalVAV-7 (T-12)Tuttle & BaileyFPC D 512-7Fan, Filter
VAV-TerminalVAV-8 (TH-5)Tuttle & BaileyFPC D 250-2Fan, Filter, Hot water coil
VAV-TerminalVAV-9, VAV-10, VAV-11 (TH-7)Tuttle & BaileyFPC D 370-4Fan, Filter, Hot water coil
VAV-TerminalVAV-12 through VAV-15 (TH-10)Tuttle & BaileyFPC D 410-6Fan, Filter, Hot water coil
VAV-TerminalVAV-17, VAV-18 (TH-14)Tuttle & BaileyFPC D 614-8Fan, Filter, Hot water coil
VAV-TerminalVAV-19, VAV-20, VAV-21 (TH-16)Tuttle & BaileyFPC D 616-9Fan, Filter, Hot water coil
1502000 Spec Item 3.2 - WHE
Crane-Gantry (mobile)CGM-1Spanco (crane) Cyclone (hoist)3T1518S (crane), Series 646 (hoist)9605-82 (crane)3 Ton
Crane-Overhead BridgeCOB-1American Monorail of CaliforniaSGUHAME-82595 ton
1502000 Spec Item 3.2 - VTE
ElevatorE-1Delta Elevator Co, Inc
1502000 Spec Item 3.2 - Miscellaneous Equipment
Air CompressorAC-1Ingersoll Rand2-2545E7.501101801972 Compressors, Belt drive, Oil lubed
Air Dryer - RefrigerantADR-1Ingersoll RandSDR5000MSDRA4258R134A Refrigerant
Compressed Air -FilterAFC-1Ingersoll RandIR100CHECCN:39540353 Element:39540916
Pump (heat)P-1ArmstrongSeries 4280, Model 2X1X10Closed Couple End Suction, 3 HP, 42 GPM
Pump (potw)P-2ArmstrongLS-45BF
Slide Gate Operator & Entry SystemSGO-1Elite Access Systems IncSL-3000-UL series
Water Heater-GasWH-1LochinvarEWN150PMC014342Gas

Page &P of &N

VAV Location

J-1502000-06
PREVENTATIVE MAINTENANCE PROGRAM DETAIL
VAV LOCATION
MCRC PASAFENA, CA
VAV DesignationModel DesignationLocation
VAV-1T-7OVM/Tire Shop 136
VAV-2T-8Mt Tools 131
VAV-3T-10Comm Maint Chief 148
VAV-4T-10Supply Officer 219
VAV-5T-10S-4 225
VAV-6T-10Platoon Sgt Office 227
VAV-7T-12Reserve 1st Sgt Office 216
VAV-8TH-5Supply Staff 220
VAV-9TH-7Radio Shop 144
VAV-10TH-7Site CO Office 203
VAV-11TH-7Medical Examination 204
VAV-12TH-10Rose Conf Rm 107
VAV-13TH-10Corridor 128
VAV-14TH-10Weight Room 156
VAV-15TH-10Ops Training 212
VAV-16TH-14Commanding Officer 106
VAV-17TH-14Recreation Room 110
VAV-18TH-14Site 1st Sgt Office 202
VAV-19TH-16Corridor 151
VAV-20TH-16Corridor 151
VAV-21TH-16Adjudant 209

Page &P of &N

Detail - AF

J-1502000-06
PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL
AIR FILTER (HVAC)
MCRC PASADENA, CA
(FILTER SIZE/QUANTITY SHALL BE FIELD VERIFIED BEFORE PURCHASING REPLACEMENT FILTERS)
DESIGNATIONEQUIPMENTFILTER 1FILTER 2FILTER 3FILTER 4
SIZEQUANTITYSIZEQUANTITYSIZEQUANTITYSIZEQUANTITY
AF-1VAV-116x20x11
AF-2VAV-2
AF-3VAV-316x20x11
AF-4VAV-416x20x11
AF-5VAV-516x20x11
AF-6VAV-616x20x11
AF-7VAV-716x20x11
AF-8VAV-8
AF-9VAV-916x20x11
AF-10VAV-1016x20x11
AF11VAV-1116x20x11
AF-12VAV-1216x20x11
AF-13VAV-1316x20x11
AF-14VAV-1416x20x11
AF-15VAV-1516x16x11
AF-16VAV-1620x20x11
AF-17VAV-1716x20x11
AF-18VAV-1820x20x11
AF-19AV-1920x25x11
AF-20VAV-2020x25x11
AF-21VAV-2120x25x11
AF-22AC-124x24x29
AF-23AC-224x24x2312x25x22
AF-24FC-112x24x22
AF-25FG-116x25x24
AF-26ACPC-120x20x11

Page &P of &N

Detail - PF

J-1502000-06
PREVENTATIVE MAINTENANCE PROGRAM EQUIPMENT DETAIL
PLUMBING FIXTURE
MCRC PASADENA, CA
FIXTUREQUANTITY
Sink18
Shower Head
Toilet16
Urinal6

Page &P of &N