W912HN-18-R-3002_AMD4_V3.pdf
PDF 2 MB Posted
- Attached to
- Construction of a Standard Design Access Control Point (ACP), Project Number 70677, Ft. Gordon, GA
- Solicitation number
- W912HN18R3002
About this file
W912HN-18-R-3002 AMD4 DRAWINGS VOL3
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 18R3002vol1.PDF | ||
| amd7.pdf | ||
| W912HN-18-R-3002_AMD6_V2.PDF | ||
| W912HN-18-R-3002_AMD6_V1.PDF | ||
| 18R3002vol3.PDF | ||
| 18R3002vol1.PDF | ||
| W912HN-18-R-3002_AMD6_V3.PDF | ||
| amd6.pdf | ||
| 18R3002vol2.PDF | ||
| amd5.pdf | ||
| W912HN-18-R-3002_AMD5_V1.PDF | ||
| W912HN-18-R-3002_AMD5_V3.PDF | ||
| 18R3002vol1.PDF | ||
| 18R3002vol3.PDF | ||
| 18R3002vol1.PDF | ||
| W912HN-18-R-3002_AMD4_V2.pdf | ||
| amd4.pdf | ||
| 18R3002vol3.PDF | ||
| W912HN-18-R-3002_AMD4_V1.pdf | ||
| 18R3002vol2.PDF | ||
| amd3.pdf | ||
| 18R3002vol1.PDF | ||
| 18R3002vol1.PDF | ||
| amd2.pdf | ||
| W912HN18R3002_Amd_0001.pdf | ||
| 18R3002vol1.PDF | ||
| amd1.pdf | ||
| W912HN-18-R-3002_V3.pdf | ||
| 18R3002vol3.PDF | ||
| W912HN-18-R-3000_V2B.PDF | ||
| W912HN-18-R-3000_V2A.PDF | ||
| W912HN-18-R-3002_V1.pdf | ||
| 18R3002vol1.PDF | ||
| W912HN-18-R-3000_V2C.PDF | ||
| 18R3002vol2.PDF |
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BA
PVSC T.O. ISLAND
0"
PVSC TOS
16'-9"
A-301
A-311
PVSC BO SOFFIT
14'-11"
1 2
PVSC T.O. ISLAND
0"
PVSC TOS
16'-9"
A-301
PVSC BO SOFFIT
14'-11"
33'-4"
A-501
TSC T.O. ISLAND
0"
TSC BO SOFFIT
17'-5"
TSC TOS
18'-7"
A-301
A-311
TSC T.O. ISLAND
0"
TSC BO SOFFIT
17'-5"
TSC TOS
18'-7"
A-301
A-311
A-501
5 81'-4 7/8"
BULLET AND
BLAST
RESISTANT
FRAMING AND
GLAZING
A-301
OW GROUND
0"
OW NOMINAL HT
8'-0"
COUNTER TOP
BULLET AND
BLAST
RESISTANT
FRAMING AND
GLAZING
IDCC T.O. ISLAND
0"
COUNTER TOP
GB NOMINAL HT
8'-0" GLAZING
A-301
6.92
SAS NOMINAL HT
8'-0"
SAS GROUND
0"
GENERAL NOTES
A. REFER TO SHEET A-603 FOR
EXTERIOR FINISH LEGEND.
B. SEE SHEET G-007 FOR SITE KEY PLAN
AND BUILDING ABBREVIATIONS.
A-301
3'-1 7/8"
COUNTER TOP
OW GROUND
0"
OW NOMINAL HT
8'-0"
A-501
A-301
8.471
SAS NOMINAL HT
8'-0"
SAS GROUND
0"
GLAZING
8' 4' 0 8' 16'
1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
F O
R T
G O
R D
O N
G
E O
R G
IA
A
C C
E S
S C
O N
T R
O L P
O
IN
T F
Y
P
N
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
E O
R G
IA
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
-1
/3
/1
7 8 9 10
B
C
D
E
F
G
B G
M -1
-0
W H
N -1
-R
-3
A-301
B U
IL
D
IN
G
S E
C T
IO
N
S
K L B
K L B
C L B
ISSUED FOR CONSTRUCTION
1/8" = 1'-0"A-301
3 PVSC CROSS SECTION
1/8" = 1'-0"A-301
4 PVSC LONGITUDINAL SECTION
1/8" = 1'-0"A-301
1 TSC CROSS SECTION
1/8" = 1'-0"A-301
2 TSC LONGITUDINAL SECTION
1/8" = 1'-0"A-301
5 OW - CROSS SECTION
1/8" = 1'-0"A-301
7 GB - LONGITUDINAL SECT
1/8" = 1'-0"A-301
9 SAS - LONGITUDINAL SECTION
1/8" = 1'-0"A-301
6 OW - LONGITUDINAL SECT
1/8" = 1'-0"A-301
8 SAS - CROSS SECT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/2
/1
F FP FG
AS SCHED
WIDTH
A S
S C
H E
D
H E
IG
H
T
4" 4"
AS SCHEDULED
WIDTH
A S
S C
H E
D
H E
IG
H
T
4"
A S
S C
H E
D
H E
IG
H
T
AS SCHED
WIDTH
GL GL GL
W2 W3 W4W1
NORTH EL
(SOUTH EL OH)
F1 F2 F3
A S
S C
H E
D
H E
IG
H
T
AS SCHED
WIDTH
2" 2"
A S
S C
H E
D
H E
IG
H
T
AS SCHED
WIDTH
2" 2"
A S
S C
H E
D
H E
IG
H
T
AS SCHED
WIDTH
2" 2"
A S
S C
H E
D
H E
IG
H
T
F4
A S
S C
H E
D
H E
IG
H
T
AS SCHED
WIDTH
2"
A S
S C
H E
D
H E
IG
H
T
F5
A S
S C
H E
D
H E
IG
H
T
AS SCHED
WIDTH
2" 2"
AS SCHED
WIDTH
AS SCHED
WIDTH
GL-4 @ DOOR V100
GL-1 @ DOOR V100A
GL-1 @ DOOR V102B
GL-4 @ DOORS V102A,
V111B & V112B
GL-3 GL-3
13'-4"
GL-3 GL-3
4'-8" 3'-4" 5'-4"
TYP
2"
BLAST
RESISTANT
WINDOW AND
GLAZING
SUN SHADE
LIGHT
SHELF
GL-4
GL-4
4'-0"
TYP
2"
4'-0"
GL-5
TYP
2"
14'-2"
GL-3 GL-3 GL-3
4'-8" 4'-8" 4'-8"
TYP
2"
12" 6" 0 1' 2' 3' 4' 5' 6' 7'
3/8"=1'-0"
4' 2' 0 4' 8'
1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
F O
R T
G O
R D
O N
G
E O
R G
IA
A
C C
E S
S C
O N
T R
O L P
O
IN
T F
Y
P
N
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
E O
R G
IA
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
-1
/3
/1
7 8 9 10
B
C
D
E
F
G
B G
M -1
-0
W H
N -1
-R
-3
A-602
D O
O R
A N
D W
IN
D
O W
S C
H E
D U
L E
S
K L B
K L B
C L B
ISSUED FOR CONSTRUCTION
3/8" = 1'-0"
DOOR PANEL TYPES
CURTAIN WALL SCHEDULE
MARK
FRAME DETAIL
COMMENTSMATL FINISH HEAD JAMB SILL
W1 AL FACTORY 3/A-502 & 6/A-502 8/A-502 9/A-502 BLAST RESISTANT
W2 AL FACTORY 1/A-502 2/A-502 4/A-502 BALLISTIC RESISTANT
W3 AL FACTORY 1/A-502 2/A-502 & 5/A-502 4/A-502 BALLISTIC RESISTANT
W4 AL FACTORY 3/A-502 & 6/A-502 8/A-502 9/A-502
3/8" = 1'-0"
DOOR FRAME TYPES
1/4" = 1'-0"
WINDOW TYPES
EXTERIOR DOOR SCHEDULE
DOOR
NO.
DOOR
TYPE
GLASS
TYPE
DOOR FRAME
TRANSOM
HEIGHT HDW COMMENTS:HEIGHT WIDTH
SIZE
MATL FINISH
FIRE
RATING TYPE MATL FINISH
DETAILS
THKNS HEAD JAMB SILL
C100 F 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A503 4/A503 - 06
C101 F 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A503 4/A503 - 06
G100A FG GL-3 7'-2" 3'-0" 1 3/4" AL FACTORY 0 Hour F5 AL FACTORY 3/A-503 6/A-503 4/A-503 - 21 BULLET RESISTANT
G100B FG GL-3 7'-2" 3'-0" 1 3/4" AL FACTORY 0 Hour F5 AL FACTORY 3/A-503 6/A-503 4/A-503 - 21 BULLET RESISTANT
G103 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 04 BULLET RESISTANT
G104 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 05 BULLET RESISTANT
G105 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 05 BULLET RESISTANT
G106 F 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 05 BULLET RESISTANT
S100 FG GL-5 7'-0" 3'-0" 1 3/4" AL FACTORY 0 Hour F2 AL FACTORY 2/A-503 7/A-503 4/A-503 - 03
S104 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 02
S105 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 01
S106 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 02
V100 FP GL-4 7'-0" 3'-0" 1 3/4" AL FACTORY 0 Hour F4 AL FACTORY 1/A-503 7/A-503 4/A-503 1'-8" 19 BLAST RESISTANT
V102A FG GL-4 7'-0" 3'-0" 1 3/4" AL FACTORY 0 Hour F3 AL FACTORY 1/A-503 7/A-503 4/A-503 1'-8" 20 BLAST RESISTANT
V104 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 2/A-503 5/A-503 4/A-503 - 01 BLAST RESISTANT
V111B F - 7'-0" 3'-0" 1 3/4" AL FACTORY 0 Hour F3 AL FACTORY 1/A-503 7/A-503 4/A-503 1'-8" 22 BLAST RESISTANT
V112B F - 7'-0" 3'-0" 1 3/4" AL FACTORY 0 Hour F3 AL FACTORY 1/A-503 7/A-503 4/A-503 1'-8" 22 BLAST RESISTANT
INTERIOR DOOR SCHEDULE
DOOR
NO.
DOOR
TYPE
GLASS
TYPE
DOOR FRAME
TRANSOM
HEIGHT HDW COMMENTS:HEIGHT WIDTH
SIZE
MATL FINISH
FIRE
RATING TYPE MATL FINISH
DETAILS
THKNS HEAD JAMB SILL
G101 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 17
G102 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 14
S101 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 10
S102 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 15
S103 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 18
V100A FP GL-2 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F4 HM PNT-2 9/A-503 9/A-503 - 1'-8" 12
V102B FG GL-2 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F3 HM PNT-2 9/A-503 9/A-503 - 1'-8" 13
V103 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 14
V105 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 18
V106 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 17
V107 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 09
V108 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 16
V109 F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 11
V111A F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F1 HM PNT-2 8/A-503 8/A-503 - - 08
V112A F - 7'-0" 3'-0" 1 3/4" HM PNT-2 0 Hour F2 HM PNT-2 9/A-503 9/A-503 - - 07
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/2
VS
VS
VS
VS
VS
VS
VS
VS
OS OS
OS
OS
S
V S
V S
V S
VS
VS
VS
VS
S
S S
S
EL. 10'-0"
EL. 9'-3"
EL. 9'-0"
EL. 10'-11"
(TYP) UNO
A-601
A-601
NEXT-IN-LINE DISPLAY (NIC)
EL. 9'-4"
EL. 9'-0"
EL. 9'-0"
EL. 9'-0"
TV MONITOR
(NIC)
TV
MONITOR
(NIC)
TV
MONITOR
(NIC)
A-601
EL. 8'-8" EL. 8'-0"
EL. 8'-0"(TYP) UNO
A-601
A-601
A-601
EL. 9'-0"
A-601
A. SEE SHEET G-007 FOR SITE KEY PLAN AND
BUILDING ABBREVIATIONS.
GENERAL NOTES THIS SHEET:
2'X2" ACT GRID
GWB - PAINTED
2'X2' FLUORESCENT LIGHTS
2'X4' FLUORESCENT LIGHTS
6" DOWNLIGHT
RCP LEGEND
1'X4' LED STRIP LIGHTS
vs VACANCY SENSOR
1-HR RATED GWB CEILING
(UL I501) - PAINTED
S SMOKE DETECTOR
MECH DIFFUSER
MECH RETURN AIR
WALL MOUNTED LIGHT
PLYWD BACKERBOARD (SEE ELEC)
EXIT SIGN (SEE ELEC)
EL. 8'-8"EL. 8'-0"
EL. 8'-0" (TYP) UNO
A-601
A-601
TV
MONITOR
(NIC)
A-601
EL. 8'-8"
A-601
8' 4' 0 8' 16'
1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
C A
T E
G O
R Y
C O
D E
1 2 3 4 5
A
GRAPHIC SCALES
F O
R T
G O
R D
O N
G
E O
R G
IA
A
C C
E S
S C
O N
T R
O L P
O
IN
T F
Y
P
N
S A
V A
N N
A H
D
IS
T R
IC
T
S A
V A
N N
A H
G
E O
R G
IA
A E
C O
M S
E R
V
IC
E S
IN
C
S
J E
F F
E R
S O
N S
T S
T E
R O
A N
O K
E V
A
-1
/3
/1
7 8 9 10
B
C
D
E
F
G
B G
M -1
-0
W H
N -1
-R
-3
A-801
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N S
K L B
K L B
C L B
ISSUED FOR CONSTRUCTION
1/8" = 1'-0"A-801
1 VCC REFLECTED CEILING PLAN
1/8" = 1'-0"A-801
2 GH REFLECTED CEILING PLAN
1/8" = 1'-0"A-801
3 SAB REFLECTED CEILING PLAN
1/8" = 1'-0"A-801
4 CS REFLECTED CEILING PLAN
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E V
IS
E
D I
N A
C C
O R
D A
N C
E W
IT
H
A M
E N
D M
E N
T
/2
ELECTRICAL ONE-LINE DIAGRAM
CIRCUIT BREAKER WITH TRIP RATING AS INDICATED
POWER TRANSFORMER WITH DELTA CONNECTED PRIMARY, WYE
CONNECTED SECONDARY; ISOLATION TRANSFORMER INDICATED ON
RISER.
SURGE PROTECTION DEVICE (INTERNAL).
100A
SPD
30 kVA RATING AS INDICATED
CT CURRENT TRANSFORMER
PT
POWER TRANSFORMER
E ELECTRIC OPERATOR
ENCLOSED CIRCUIT BREAKER
LEGEND TELECOM AND SIGNAL SYSTEMS
DATA OUTLET, MH 18" AFF UON NOTED. PROVIDE JUNCTION BOX CONNECTED
BY MINIMUM 1" EMT CONDUIT WITH PULL STRING.
HORIZONTAL WIRE MESH CABLE TRAY.
TELEPHONE OUTLET, MH 4'-0" AFF UNLESS OTHERWISE NOTED. PROVIDE
JUNCTION BOX CONNECTED BY MINIMUM 1" EMT CONDUIT WITH PULL STRING.
TELEPHONE TERMINAL BOARD.
COMBINATION DATA AND POWER FLOOR BOX. PROVIDE MINIMUM 1" EMT
CONDUIT WITH PULL STRING
JUNCTION BOX, PULL BOX, AND OR OUTLET. PROVIDE CONNECTORS,
CONDUIT, FITTINGS, ETC. THE LEG INDICATES WALL MOUNTED, CIRCLE
INDICATES CEILING MOUNTED, AND THE SQUARE INDICATES FLOOR
MOUNTED. PROVIDE OUTLET AND PATHWAY FOR AV EQUIPMENT WITH
PULL STRING FOR AV ONLY. FOR AV LOCATIONS PROVIDE 2 GANG
BACKBOX WITH 1 1/4" EMT CONDUIT.
J J
AV AV
NF NON-FUSED DISCONNECT SWITCH. 60 = SWITCH RATING,
NF = NON-FUSIBLE.
CCTV OUTLET. PROVIDE JUNCTION BOX CONNECTED BY MINIMUM 1" EMT
CONDUIT WITH PULL STRING. SEE SHEET E-604 FOR SECURITY CAMERA
SCHEDULE.
EQUIPMENT RACK GOVERNMENT FURNISHED GOVERNMENT INSTALLED (GFGI).
BS
BALANCED MAGNETIC SWITCH OUTLET BOX. PROVIDE JUNCTION BOX
CONNECTED BY MINIMUM 1-1/4" EMT CONDUIT WITH PULL STRING WITHIN
PERIMETER OF THE PROTECTED AREA.
GENERAL NOTES TELECOM AND SIGNAL SYSTEMS
1 MOUNT DATA OUTLET BOXES AT SAME HEIGHT AS ELECTRICAL OUTLETS UON ON
SHEET.
2. MOUNT OUTLET BOXES SO THAT NONE OCCUR BACK TO BACK IN WALLS.
3. INSTALLATION OF CABLE PATHWAYS AND DEVICES SHALL BE IN COMPLIANCE
WITH NFPA 70, TIA/EIA- 569-D, I3A AND UFC 3-580-01.
4. TELECOMMUNICATIONS GROUNDING AND BONDING SHALL BE IN COMPLIANCE
WITH NFPA 70 ANSI-D, I3A TIA-607-C.
5. PROVIDE MINIMUM 1-INCH EMT CONDUIT FROM EACH WALL MOUNTED
TELECOMMUNICATIONS OUTLET DOWN INSIDE THE WALL TO ABOVE THE
ACCESSIBLE CEILING.
6. PROVIDE PULL STRING IN ALL EMPTY CONDUITS SERVING GOVERNMENT
INSTALLED EQUIPMENT. PULL STRING TO BE RATED FOR 100 LBS.
7. VERIFY AND COORDINATE EXACT LOCATION OF ALL WALL, FLOOR, AND CEILING
MOUNTED DEVICES WITH CLIENT AND ARCHITECTURAL ELEVATIONS.
8. ALL COPPER TERMINATION HARDWARE TO BE 110 STYLE IDC UON ON SHEET.
9. TERMINATE ALL OUTSIDE PLANT CABLING AS INDICATED ON THE SITE
TELECOMMUNICATIONS DRAWINGS (TS SHEETS).
10. MONITOR CABLE PULL TENSION TO ENSURE MANUFACTURER RECOMMENDATION
AND INDUSTRY STANDARDS ARE NOT EXCEEDED.
11. PROVIDE PULL BOXES IN CONDUITS NO MORE THAN 100-FEET APART AND PER
EVERY 180 DEGREES OF BEND.
12. SEE AD SERIES SHEETS FOR DEMOLITION NOTES AND REQUIREMENTS.
SECURITY PUSH BUTTON. LEG DESIGNATES WALL MOUNT. PROVIDE
JUNCTION BOX CONNECTED BY 1" MIN. EMT CONDUIT WITH PULL STRING.
SUBSCRIPTS INDICATE THE FOLLOWING:
D DURESS - MOUNTED UNDERCOUNTER OR OUT OF NORMAL VIEW.
P PANIC
A DOOR OPERATOR - MOUNTED 48" AFF, UON.
E EMERGENCY FAST OPERATE (EFO), MOUNTED 48" AFF UON.
D D
TTB
DATA/TELEPHONE COMBINATION OUTLET, MH 18" AFF UNLESS
OTHERWISE NOTED. PROVIDE JUNCTION BOX CONNECTED BY
MINIMUM 1" EMT CONDUIT WITH PULL STRING
TV TELEVISION WALL BOX. PROVIDE TWO GANG BOX WITH DIVIDER. ONE
GANG SHALL BE 120V DUPLEX RECEPTACLE. THE OTHER GANG SHALL
BE 1" MINIMUM EMT CONDUIT WITH PULL STRING TO ABOVE
ACCESSIBLE CEILING FOR GFGI SIGNAL CABLE.
VA SYSTEM MICROPHONE OUTLET. PROVIDE OUTLET CONNECTED BY
1" MIN. EMT CONDUIT.
VA SYSTEM LOUD-SPEAKER. PROVIDE LOUD-SPEAKER CONNECTED BY
1" MIN. EMT CONDUIT.
100N FEEDER TAG, REFER TO FEEDER SCHEDULE FOR DESIGNATION
MBCEM MULTI-BRANCH CIRCUIT ENERGY MONITOR
METERING CT
REMOTE MONITORING PANEL.RMP
(NEC) NETWORK ENTERPRISE CENTER (TELECOM CONTEXT)
PBB PRIMARY BONDING BUSBAR, MH 18".
SBB SECONDARY BONDING BUSBAR, MH 18".
VCC
SAB
IDCC
PVSC
TSC
GH
APPROXIMATE START LOCATION OF
ACP. COORDINATE EXACT EXTENTS
OF ACP WITH CIVIL DRAWINGS.
APPROXIMATE END LOCATION OF ACP. COORDINATE EXACT ACP
EXTENTS WITH CIVIL DRAWINGS. ALL SITE LIGHTING FIXTURES
WITHIN ACP SHALL BE CONNECTED TO PANEL 'A1' IN GATEHOUSE.
OW
CS
BUILDING DESIGNATIONS:
PVSC
VCC
IDCC
SAB
TSC
GH
OW
CS
- PERSONAL VEHICLE SEARCH CANOPY
- VISITOR CONTROL CENTER
- I.D. CHECK CANOPY
- SEARCH AREA BUILDING
- TRUCK SEARCH CANOPY
- GATEHOUSE
- OVERWATCH
- COMMUNICATIONS SHELTER
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AC
C
ES
S
C O
N
TR
O L
PO
IN
T
FY
8, P N
SA
VA
N
N
AH
D
IS
TR
IC
T
SA
VA
N
N
AH
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
ES
, I
N C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
/3
1/
7 8 9 10
B
C
D
E
F
G
BG
M
1-
-0
W
2H N
-1 8-
R -3
E-002
EL
EC
TR
IC
AL
L
EG
EN
D
M B
M V
M B
ISSUED FOR CONSTRUCTION
N.T.S.E-002
1 ACP SITE PLAN (FOR REFERENCE ONLY)
APPROACH ZONE 2508
FEET TO GORDON HIGHWAY
ACCESS CONTROL ZONE
437 FEET
RESPONSE ZONE 1720 FEET
TO ACTIVE VEHICLE
BARRIER
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
RE
VI
SE
D
IN
A
CC
O
RD
AN
CE
W
IT
H
AM
EN
DM
EN
T
3/
/1
VS
VS
VS
VS
VS
VS
J
TV
TV
J
VS
AA
BREAK ROOM
SAB-101
LATRINE
SAB-103
INSIDE STORAGE
SAB-102
OUTSIDE
STORAGE
SAB-104
MECH/ELEC
SAB-105
COMMUNICATIONS
SAB-106
OFFICE
SAB-100
G
WP
G
WP
G
AC
G
AC
G
AC
SAB-DSS-1
SAB-DSS-2
SAB-CU-3
SAB-DSS-3
SAB-CU-1
SAB-CU-2SAB-EF-1
S1
G
WP
G
AC
G G
SAB-DWH-3
G
SAB-SF-1
US1-11
S1-22
S1-2
S1-12
S1-6
S1-9
S1-13
G
S1-4
G
WP
E-107
S1-20
S1-31
Microwave
Coffeemaker
S1-19
Refrigerator
SAB-UH-1
BREAK ROOM
SAB-101
LATRINE
SAB-103 INSIDE STORAGE
SAB-102
OUTSIDE
STORAGE
SAB-104
MECH/ELEC
SAB-105
COMMUNICATIONS
SAB-106
OFFICE
SAB-100
S1
S2
S2
S2
S2
TTB-6
5 5
D
BSBS
BS
BS
KEYNOTES
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
120V POWER TO FLUSH VALVE TRANSFORMER.
COORDINATE EXACT LOCATION WITH PLUMBING
CONTRACTOR PRIOR TO ROUGH IN.
GFCI RECEPTACLE MOUNTED BELOW SINK FOR
CONNECTION TO SENSOR FAUCET POWER
SUPPLY.
GFCI PROTECTION ON CIRCUIT BREAKER.
CABLE TRAY: 6"W x 4"H, MOUNT 8' AFF.
WALL MOUNTED EQUIPMENT RACK (GFGI).
COORDINATE EXACT MOUNTING HEIGHT AND
LOCATION WITH ARCHITECTURAL DRAWINGS PRIOR
TO ROUGH-IN.
APPROXIMATE LOCATION OF GFGI AIE WALL
MOUNTED EQUIPMENT CABINET. COORDINATE WITH
EMPTY CONDUIT SYSTEM.
APPROXIMATE LOCATION OF GFGI ESS CONTROL
PANEL. COORDINATE WITH EMPTY CONDUIT
SYSTEM.
APPROXIMATE LOCATION OF GFGI ESS/AIE PULL
BOX ABOVE ACCESSIBLE CEILING.
PROVIDE 1" CONDUIT WITH PULL STRING ABOVE
ACCESSIBLE CEILING.
CORRIDATE RECEPTACLE MOUNTING HEIGHT SUCH
THAT RECEPTACLE OCCURS IN THE BOTTOM OF
CABINET.
PROVIDE AN EMPTY BOX MOUNTED AT 18" AFF ON
WALL FOR THE UNDER VEHICLE INSPECTION
SYSTEM.
POWER GENERAL NOTES
1. COORDINATE RECEPTACLE MOUNTING HEIGHTS AND
LOCATIONS WITH ARCHITECTURAL DETAILS AND
ELEVATIONS PRIOR TO ROUGH-IN.
2. RECEPTACLES MOUNTED IN BATHROOMS,
KITCHENS, ROOFTOP, AND AT EXTERIOR LOCATIONS
SHALL BE GFCI TYPE. EXTERIOR RECEPTACLES
SHALL BE WEATHERPROOF (WP) TYPE WITH 'IN-USE'
COVER PLATES. RECEPTACLES WITHIN SIX (6) FEET
OF A SINK OR BASIN, AND SERVING VENDING
MACHINES SHALL BE GFCI TYPE. REFER TO NEC
210.8(B) FOR ADDITIONAL LOCATIONS WHERE GFCI
RECEPTACLES ARE REQUIRED.
3. LABEL WIRING DEVICE WALL PLATES WITH
PERMANENT ADHESIVE LABELS (BLACK LETTERS ON
CLEAR BACKGROUND, 1/8" MINIMUM LETTERING
HEIGHT) INDICATING PANEL AND CIRCUIT
NUMBERING SERVING THE DEVICE.
4. CONTRACTOR SHALL PREPARE TYPEWRITTEN
PANEL DIRECTORIES FOR EACH PANEL. DIRECTORY
SHALL UTILIZE EXACT ROOM NUMBERS/NAMES AS
SHOWN ON ARCHITECTURAL PLANS AND SHALL
INDICATE WHERE THE POWER SUPPLY ORIGINATES.
DIRECTORIES SHALL SPECIFICALLY COMPLY WITH
NEC 408.4.
5. REFER TO SPECIFICATIONS FOR REQUIREMENTS.
6. BRANCH CIRCUITING DOES NOT INDICATE QUANTITY
OF CONDUCTORS. CONTRACTOR SHALL PROVIDE
REQUIRED QUANTITIES FOR FUNCTIONS INDICATED
BY HOMERUNS. EACH CONDUIT RUN SHALL HAVE A
GREEN INSULATED GROUNDING CONDUCTOR.
MINIMUM (2)#12, (1)#12G, 1/2"C.
7. BRANCH CIRCUIT HOMERUNS SHALL BE LIMITED TO
3% VOLTAGE DROP, INCREASE CONDUCTOR AWG
SIZE ACCORDINGLY TO LIMIT VOLTAGE DROP TO 3%.
HOMERUNS LESS THAN 100FT MAY BE #12AWG.
HOMERUNS GREATER THAN 100FT SHALL BE
MINIMUM 10AWG.
8. REFER TO MECHANICAL EQUIPMENT SCHEDULE
FOR EQUIPMENT LOADS SEE SHEET E-604.
COORDINATE EXACT REQUIREMENTS WITH
MECHANICAL EQUIPMENT SUPPLIER PRIOR TO
ROUGH-IN.
SYSTEMS GENERAL NOTES
1. COORDINATE DEVICE MOUNTING HEIGHTS AND
LOCATIONS WITH ARCHITECTURAL DETAILS AND
ELEVATIONS PRIOR TO ROUGH-IN.
2. DURESS ALARMS SHALL ANNUNCIATE AT BOTH THE
COMMAND AND CONTROL LOCATION AND BASE
CENTRAL SECURITY MONITORING.
3. CCTV CAMERAS SHALL HAVE SUFFICIENT
RESOLUTION AND WIDE DYNAMIC RANGE FOR REAL
TIME ASSESSMENT OF ACTIVITY DETAIL. REFER TO
E-603 "SECURITY CAMERA SCHEDULE" FOR
INDIVIDUAL CAMERA REQUIREMENTS.
4. HANDHOLES THAT CONTAIN DURESS, CCTV,
INTRUSION DETECTION, OR AVB WIRING SHALL BE
EQUIPPED WITH TAMPER SWITCHES ON THE COVER.
5. SECURITY DEVICES AND CAMERAS ARE NOT
FURNISHED UNDER 'MILCON'. CABLING PROVIDED BY
OTHERS.
6. COORDINATE INSTALLATION REQUIREMENTS WITH
THE NETWORK ENTERPRISE CENTER (NEC).
7. COMMUNICATIONS DEVICES FOR OVERWATCH
BUILDING SHALL HOMERUN TO COMMUNICATIONS
BUILDING.
US1
TTB-6
US1-1
US1-6,8
US1-7
US1-9
'US1'
UPS
US1-12,14 US1-10
US1-2,4
TTB-6
WALL- MOUNT
EQUIPMENT RACK
(GFGI)
CABLE TRAY
INCOMING
FIBER
FIBER
PATCH
PANEL
EXTEND 4" CONDUIT TO ABOVE CEILING
AT AIE CABINET AND ESS CONTROL PANEL
TSC
10 TYP
J
GFGI
AIE
EQUIPMENT
CABINET
1" EMPTY CONDUIT
WITH PULL STRING
(TYP)
PULL BOX
(ESS/AIE)
20"Wx20L"x8"D
GFGI
ESS
CONTROL
CABINET
D
BS
CAMERA
OUTLET
ROOF
FLOOR
FOUR 2" EMPTY CONDUITS
WITH PULL STRING FOR
EACH CABINET (TYP)
12" 6" 0 1' 2' 3' 4' 5' 1/2"=1'-0"
4' 2' 0 4' 8' 1/4"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
ER
S
D R
AW
N
B Y
D E
SI
G
N
ED
B Y:
S U
BM
IT
TE
D
B Y
S
IZ
E
C H
EC
K
E D
B Y:
A N
SI
'D
FI
LE
N
AM
E:
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
AT
IO
N
N O
C A
TE
G
O R
Y C
O D
E
1 2 3 4 5
A
GRAPHIC SCALES
FO
R
T G
O R
D O
N , G
EO
R
G
IA
A C
C E
SS
C
O N
TR
O
L P
O
IN
T
FY
8, P N
S
A
VA
N N
AH
D
IS
TR
IC
T
S A
VA
N
N A
H , G
E O
R G
IA
A E
C O
M S
ER
V
IC
ES
, I N
C
S
J E
FF
E
R S
O N
S T
S
TE
R
O A
N O
K E
V A
-1
/3
1/
7 8 9 10
B
C
D
E
F
G
B G
M
1-
-0
W
2H N
-1 8-
R -3
E-107
P O
W
ER
/S Y
ST
EM
S S
AB
F
LO
O
R P
LA
N
S
M B
M V
M B
ISSUED FOR CONSTRUCTION
1/4" = 1'-0"E-107 1 E - D - FP - Ground Floor SAB
1/4" = 1'-0"E-107 3 T - D - FP - Ground Floor SAB
N
1/2" = 1'-0"E-107 2 E - D - FP - Communications SAB
N.T.S.E-107
4 SAB TELECOM RISER
N.T.S.E-107
5 SAB SECURITY RISER
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
RE
VI
SE
D
IN
A
CC
O
RD
AN
CE
W
IT
H
AM
EN
DM
EN
T
3/
St or m St or m
St or m
Stor m Stor m
Stor m
St or m
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
HH
St or m
Stor m
HH
HH
HH
I.CI.BI.A
I.4
E-111
(TYP.)
CONTINUE TO
GATEHOUSE
AIE SYSTEMS TELECOMM
1914 13
I.CI.BI.A
GUARD
BOOTH
I1
I2
2 3 5
E-111
3(TYP.)
DRIVER
INTERFACE
LOOP
TRAFFIC
ARM
LOOP
D
ROADWAY
GATEHOUSE
SECURITY
ROOM
(TYP.)
(TYP.)
TRAFFIC
ISLAND
GUARD
BOOTH
#1
GUARD
BOOTH
#2
GUARD
BOOTH
#3
GUARD
BOOTH
#4
GUARD
BOOTH
#5
GUARD
BOOTH
#6
GUARD
BOOTH
#7
SYSTEMS GENERAL NOTES
1. COORDINATE DEVICE MOUNTING HEIGHTS AND
LOCATIONS WITH ARCHITECTURAL DETAILS AND
ELEVATIONS PRIOR TO ROUGH-IN.
2. DURESS ALARMS SHALL ANNUNCIATE AT BOTH THE
COMMAND AND CONTROL LOCATION AND BASE
CENTRAL SECURITY MONITORING.
3. CCTV CAMERAS SHALL HAVE SUFFICIENT
RESOLUTION AND WIDE DYNAMIC RANGE FOR REAL
TIME ASSESSMENT OF ACTIVITY DETAIL. REFER TO
E-603 "SECURITY CAMERA SCHEDULE" FOR
INDIVIDUAL CAMERA REQUIREMENTS.
4. HANDHOLES THAT CONTAIN DURESS, CCTV,
INTRUSION DETECTION, OR AVB WIRING SHALL BE
EQUIPPED WITH TAMPER SWITCHES ON THE COVER.
5. SECURITY DEVICES AND CAMERAS ARE NOT
FURNISHED UNDER 'MILCON'. CABLING PROVIDED BY
OTHERS.
6. COORDINATE INSTALLATION REQUIREMENTS WITH
THE NETWORK ENTERPRISE CENTER (NEC).
7. COMMUNICATIONS DEVICES FOR OVERWATCH
BUILDING SHALL HOMERUN TO COMMUNICATIONS
BUILDING.
KEYNOTES
1. OVER SPEED AND WRONG-WAY ANNUNCIATOR ALARM
PANEL.
2. (FUTURE) TAG CAMERA MOUNTED ON PEDESTAL.
3. (FUTURE) DRIVER INTERFACE (CARD READER
PEDESTAL & DRIVER FACE CAMERA).
4. VISUAL LANE INDICATOR. COORDINATE MOUNTING
HEIGHT WITH ARCHITECTURAL DRAWINGS. CONNECT TO
CONTROL SWITCH IN RESPECTIVE GUARD BOOTH.
REFER TO LIGHTING FIXTURE SCHEDULE ON E-604 FOR
ADDITIONAL REQUIREMENTS.
5. (FUTURE) TRAFFIC ARM AND SIGNAL.
6. CCTV CABINET.
7. TELECOM HANDHOLE. REFER TO DETAIL ON E-501 FOR
ADDITIONAL REQUIREMENTS.
8. AIE SYSTEM HANDHOLE. REFER TO DETAIL ON E-501
FOR ADDITIONAL REQUIREMENTS.
9. PROVIDE (1) - 1-1/2"C, DIRECT BURIED. STUB UP
CONDUIT FLUSH WITH FINISHED CONCRETE AT POINT
OF TERMINATION. REFER TO CONDUIT DETAIL ON 2/E-
507.
10. PROVIDE (1) - 2"C, DIRECT BURIED. STUB UP CONDUIT
FLUSH WITH FINISHED CONCRETE AT POINT OF
TERMINATION. REFER TO CONDUIT DETAIL ON 2/E-507.
11. (1) - 1"C, SURFACE MOUNT TO UNDERSIDE OF CANOPY.
12. UNDERGROUND CONDUIT TRANSITION TO
SURFACE CONDUIT. MOUNT CONDUIT TO
EXTERIOR OF COLUMN AND CONTINUE ALONG
UNDERSIDE OF CANOPY.
13. INCOMING CONDUIT FOR TELECOM FROM
GATEHOUSE.
14. INCOMING CONDUIT FOR AI SYSTEM FROM
GATEHOUSE.
15. PROVIDE CONDUIT FOR IDCC TRAFFIC ISLAND
TELECOM AND AIE TO GATEHOUSE COMM ROOM.
SEE SITE PLAN FOR CONTINUATION OF CONDUIT
ROUTING.
16. 7 SETS, (1) - 1-1/2"C, DIRECT BURIED.
17. (1) - 1-1/2"C.
18. (1) - 1-1/2"C, DIRECT BURIED.
19. (1) - 4"C, DIRECT BURIED.
20. AVB CONTROL PANEL (PROVIDED BY OTHERS).
21. FURNISHED WITH PRE-FAB GUARD BOOTH.
22. LOOP DETECTOR. CONFIRM EXACT CONNECTION
AND LOCATION REQUIREMENTS PRIOR TO
INSTALLATION.
23. VISUAL LANE INDICATOR CONTROL SWITCH
(OPEN/CLOSE).
(TYP.)
BS
BSJ
E
D E
4' 2' 0 4' 8' 1/4"=1'-0"
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
GRAPHIC SCALES
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AC
C
ES
S
C O
N
TR
O L
PO
IN
T
FY
8, P N
SA
VA
N
N
AH
D
IS
TR
IC
T
SA
VA
N
N
AH
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
ES
, I
N C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
/3
1/
7 8 9 10
B
C
D
E
F
G
BG
M
1-
-0
W
2H N
-1 8-
R -3
E-111
SY
ST
EM
S
ID
C
C F
LO
O
R P
LA
N
M B
M V
M B
ISSUED FOR CONSTRUCTION
1/8" = 1'-0"E-111 1 T - D - FP - Ground Floor IDCC
1/8" = 1'-0"E-111 2 Traffic Island Telecomm IDCC (Typ.)
N.T.S.E-111 4 Guard Booth Telecomm Riser Diagram
1/4" = 1'-0"E-111 3 Security Floor Plan (Typical)
Guard Booth Telecom/
N
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
RE
VI
SE
D
IN
A
CC
O
RD
AN
CE
W
IT
H
AM
EN
DM
EN
T
3/
/1
StormStorm
Storm Storm
HH
J
StormStorm
Storm Storm
HH
J
J
StormStorm
Storm Storm
T.B
T.A
G
WP
G
WP
CONTINUE
TO SAB
S1-29
T.B
T.A
A
A
A
A A
A A
A
S1-7
S1-8
T.B
T.A
T1
T1
CONTINUE
TO SAB
6 7
1 WP
KEYNOTES
1. (1) - 1-1/2" EMPTY CONDUIT WITH PULL STRING FOR
UNDER VEHICLE SURVEILLANCE SYSTEM.
2. (1) - 1-1/2"C, UNDERGROUND CONCRETE ENCASED.
STUB UP 3" AFF AT POINT OF TERMINATION.
3. REFER TO SITE PLAN FOR CONDUIT REQUIREMENTS.
4. CONNECT TSC POWER TO PANEL 'S1' IN SAB. SEE
SITE PLAN FOR CONTINUATION OF CONDUIT
ROUTING.
5. (1) - 1"C, UNDERGROUND CONCRETE ENCASED.
TERMINATE IN COLUMN MOUNTED RECEPTACLE.
6. UNDERGROUND CONDUIT TRANSITION TO SURFACE
CONDUIT. MOUNT CONDUIT TO EXTERIOR OF COLUMN
AND CONTINUE TO UNDERSIDE ON CANOPY.
7. (1) - 1"C, SURFACE MOUNT TO UNDERSIDE OF CANOPY.
8. PROVIDE CONDUIT TO CAMERA AT UNDERSIDE OF
CANOPY.
9. COORDINATE EXACT LOCATION PRIOR TO ROUGH-IN.
FOR UNDER VEHICLE SURVEILLANCE SYSTEM.
10. PROVIDE AN EMPTY WEATHER PROOF JUNCTION BOX
MOUNTED ON THE COLUMN AT 18" AFF FOR UNDER
VEHICLE INSPECTION CAMERA SYSTEM.
10. CONNECT TSC TELECOM TO ABOVE CEILING AT AIE
CABINET AND ESS CONTROL PANEL IN SAB. SEE
SITE PLAN FOR CONTINUATION OF CONDUIT ROUTING.
11. CONNECT HAND/OFF/AUTO SWITCH TO CONTROLCANOPY
LIGHT FIXTURES AT GUARD HOUSE.
12. BOND GROUNDING ELECTRODE TO
STRUCTURAL STEEL/ METAL FRAMEWORK.
13. DOWN CONDUCTOR WITH TEST CLAMP. ROUTE
AND CONNECT TO GROUNDING CONDUCTOR RING.
14. ROOF MOUNTED LIGHTNING CONDUCTOR.
15. GROUNDING CONDUCTOR BURIED. COORDINATE
BURIED DEPTH WITH NFPA 780 AND SPECIFICATIONS.
POWER GENERAL NOTES
1. COORDINATE RECEPTACLE MOUNTING HEIGHTS AND
LOCATIONS WITH ARCHITECTURAL DETAILS AND
ELEVATIONS PRIOR TO ROUGH-IN.
2. RECEPTACLES MOUNTED IN BATHROOMS,
KITCHENS, ROOFTOP, AND AT EXTERIOR LOCATIONS
SHALL BE GFCI TYPE. EXTERIOR RECEPTACLES
SHALL BE WEATHERPROOF (WP) TYPE WITH 'IN-USE'
COVER PLATES. RECEPTACLES WITHIN SIX (6) FEET
OF A SINK OR BASIN, AND SERVING VENDING
MACHINES SHALL BE GFCI TYPE. REFER TO NEC
210.8(B) FOR ADDITIONAL LOCATIONS WHERE GFCI
RECEPTACLES ARE REQUIRED.
3. LABEL WIRING DEVICE WALL PLATES WITH
PERMANENT ADHESIVE LABELS (BLACK LETTERS ON
CLEAR BACKGROUND, 1/8" MINIMUM LETTERING
HEIGHT) INDICATING PANEL AND CIRCUIT
NUMBERING SERVING THE DEVICE.
4. CONTRACTOR SHALL PREPARE TYPEWRITTEN
PANEL DIRECTORIES FOR EACH PANEL. DIRECTORY
SHALL UTILIZE EXACT ROOM NUMBERS/NAMES AS
SHOWN ON ARCHITECTURAL PLANS AND SHALL
INDICATE WHERE THE POWER SUPPLY ORIGINATES.
DIRECTORIES SHALL SPECIFICALLY COMPLY WITH
NEC 408.4.
5. REFER TO SPECIFICATIONS FOR REQUIREMENTS.
6. BRANCH CIRCUITING DOES NOT INDICATE QUANTITY
OF CONDUCTORS. CONTRACTOR SHALL PROVIDE
REQUIRED QUANTITIES FOR FUNCTIONS INDICATED
BY HOMERUNS. EACH CONDUIT RUN SHALL HAVE A
GREEN INSULATED GROUNDING CONDUCTOR.
MINIMUM (2)#12, (1)#12G, 1/2"C.
7. BRANCH CIRCUIT HOMERUNS SHALL BE LIMITED TO
3% VOLTAGE DROP, INCREASE CONDUCTOR AWG
SIZE ACCORDINGLY TO LIMIT VOLTAGE DROP TO 3%.
HOMERUNS LESS THAN 100FT MAY BE #12AWG.
HOMERUNS GREATER THAN 100FT SHALL BE
MINIMUM 10AWG.
8. REFER TO MECHANICAL EQUIPMENT SCHEDULE
FOR EQUIPMENT LOADS SEE SHEET E-604.
COORDINATE EXACT REQUIREMENTS WITH
MECHANICAL EQUIPMENT SUPPLIER PRIOR TO
ROUGH-IN.
LIGHTING GENERAL NOTES
1. CONNECT EMERGENCY FIXTURE AND EXIT SIGN
EMERGENCY BATTERY PACK TO LIGHTING CIRCUIT
AHEAD OF SWITCHING.
2. LIGHTING CONTROL MANUFACTURER SHALL PROVIDE
EQUIPMENT SHOP DRAWINGS FOR ENGINEERS
REVIEW PRIOR TO INSTALLATION.
3. FURNISH EXTERIOR FIXTURES WITH PHOTOCELL
CONTROL.
SYSTEMS GENERAL NOTES
1. COORDINATE DEVICE MOUNTING HEIGHTS AND
LOCATIONS WITH ARCHITECTURAL DETAILS AND
ELEVATIONS PRIOR TO ROUGH-IN.
2. DURESS ALARMS SHALL ANNUNCIATE AT BOTH THE
COMMAND AND CONTROL LOCATION AND BASE
CENTRAL SECURITY MONITORING.
3. CCTV CAMERAS SHALL HAVE SUFFICIENT
RESOLUTION AND WIDE DYNAMIC RANGE FOR REAL
TIME ASSESSMENT OF ACTIVITY DETAIL. REFER TO
E-603 "SECURITY CAMERA SCHEDULE" FOR
INDIVIDUAL CAMERA REQUIREMENTS.
4. HANDHOLES THAT CONTAIN DURESS, CCTV,
INTRUSION DETECTION, OR AVB WIRING SHALL BE
EQUIPPED WITH TAMPER SWITCHES ON THE COVER.
5. SECURITY DEVICES AND CAMERAS ARE NOT
FURNISHED UNDER 'MILCON'. CABLING PROVIDED BY
OTHERS.
6. COORDINATE INSTALLATION REQUIREMENTS WITH
THE NETWORK ENTERPRISE CENTER (NEC).
7. COMMUNICATIONS DEVICES FOR OVERWATCH
BUILDING SHALL HOMERUN TO COMMUNICATIONS
BUILDING.
T.B
T.A
E-502
(TYP.)
(TYP.)
(TYP.)
(TYP.)
E-502
(TYP.)
E-502
(TYP.)
(TYP.)
LIGHTNING PROTECTION
GENERAL NOTES
1. THE CONTRACTOR SHALL PROVIDE A COMPLETE
U.L. MASTER LABEL INSPECTION CERTIFIED
LIGHTNING PROTECTION SYSTEM FOR THE
PROJECT PER NFPA 780 AND UFC 3-575-01.
2. THE LIGHTNING PROTECTION SYSTEM INSTALLER
(LPI CERTIFIED) SHALL SUBMIT INSPECTION TO
ENGINEER FOR REVIEW PRIOR TO ANY
MODIFICATION TO THE SYSTEM.
3. PROVIDE APPROPRIATE MOUNTING
HARDWARE TO MATCH THE SURFACE
ONTO WHICH THE SYSTEM DEVICES (AIR
TERMINALS, BONDING PLATES, ETC.) ARE TO BE
MOUNTED.
4. LIGHTNING PROTECTION SYSTEM INSTALLATION
SHALL COMPLY WITH NFPA 780 AND UFC 3-575-01.
5. SURGE PROTECTION IS REQUIRED PER UFC 3-575-
01, UFC 3-520-01, EXTERIOR PANELBOARDS AND
PANELBOARDS THAT ARE PRIMARY POWER FOR
COMMUNICATIONS, LAN, SECURITY, AND ACTIVE
VEHICLE BARRIER EQUIPMENT.
8' 4' 0 8' 16' 1/8"=1'-0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
ER
S
D R
AW
N
B Y
D E
SI
G
N
ED
B Y:
S U
BM
IT
TE
D
B Y
S
IZ
E
C H
EC
K
E D
B Y:
A N
SI
'D
FI
LE
N
AM
E:
IS
S
U E
D A
TE
C O
N
TR
A C
T N
O
S O
LI
C
IT
AT
IO
N
N O
C A
TE
G
O R
Y C
O D
E
1 2 3 4 5
A
GRAPHIC SCALES
FO
R
T G
O R
D O
N , G
EO
R
G
IA
A C
C E
SS
C
O N
TR
O
L P
O
IN
T
FY
8, P N
S
A
VA
N N
AH
D
IS
TR
IC
T
S A
VA
N
N A
H , G
E O
R G
IA
A E
C O
M S
ER
V
IC
ES
, I N
C
S
J E
FF
E
R S
O N
S T
S
TE
R
O A
N O
K E
V A
-1
/3
1/
7 8 9 10
B
C
D
E
F
G
B G
M
1-
-0
W
2H N
-1 8-
R -3
E-115
E
LE
C
TR
IC
AL
/S
YS
TE
M
S/
LI
G H
TN
IN
G P
R O
TE
C
TI
O
N T
S C
P
LA
N S
M B
M V
M B
ISSUED FOR CONSTRUCTION
1/8" = 1'-0"E-115 1 E - D - FP - Ground Floor TSC
1/8" = 1'-0"E-115 2 E - D - RCP - Ground Floor TSC
1/8" = 1'-0"E-115 3 T - D - FP - Ground Floor TSC
N
1/8" = 1'-0"E-115 5 G - D - FP - Ground Floor TSC
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
RE
VI
SE
D
IN
A
CC
O
RD
AN
CE
W
IT
H
AM
EN
DM
EN
T
3/
UTILITY PAD-MOUNT
TRANSFORMER
150kVA, 15kV/ 208V
TO UTILITY
GENERATOR PANEL (BY MFR)
208Y/120V, 3PH, 4W,
600A,65kAIC RATING
400A 3P
GENERATOR
130kW 208Y/120V
3PH
ATS
PANEL 'V1'
(VISITOR CONTROL CENTER)
PANEL 'G1'
(GATEHOUSE)
PANEL 'S1'
(SEARCH AREA BUILDING)
DISTRIBUTION BOARD 'MDP1'
(GATEHOUSE)
400A, 208Y/120V, 3PH, 4W
SPD
UTILITY PAD-MOUNT
TRANSFORMER
50kVA, 15kV/ 240V
TO UTILITY
ATS
PANELBOARD 'C1'
(COMM SHELTER)
200A, 240/120V, 1PH, 3W
SPD
ACCESS CONTROL POINT AREA RESPONSE ZONE
ATS
PANELBOARD 'L1'
(GATEHOUSE)
125A, 240/120V, 1PH, 3W
125A 2P
UTILITY PAD-MOUNT
TRANSFORMER
37.5kVA, 15kV/ 240V
TO UTILITY
7 8 8 7
8 7
PANEL 'UV1'
GENERATOR
50kW 240/120V
1PH
200A 2P
125 400N
400N
400N
225N 150N 150N 100N
60N
ATS
60A 2P
(TYP.)
60N
SPD
60N
SPD
60N
SPD
(TYP. OF 7)
E-109
UPS 'UV1'
PANEL 'UV2'
PANEL 'V2'
100N
UPS 'UV2'
PANEL 'UG1'
60N
UPS 'UG1'
PANEL 'UG2'
UPS 'UG2'
PANEL 'US1'
60N
UPS 'US1'
PANEL 'UC1'
UPS 'UC1'
E-501
(TYP.)
60N 80 60N 80 60N
SPD
PANEL 'VM'
100N
15 15 15
15 15
(PRE-FAB OVERWATCH
BUILDING)
AVB
RMP
21 22
RMP
23 RMP
1 1
(TYP.)
RMP
21 27
28 28
GENERATOR PANEL (BY MFR)
240/120V, 1PH, 3W,
400A,65kAIC RATING
KEYNOTES
1. NEUTRAL-GROUND BOND.
2. 208Y/120V, 400A, 4-POLE ATS, "SERVICE ENTRANCE"
RATED WITH MAINTENANCE BYPASS ISOLATION. BOTH
SYSTEMS SHALL BE SEPARATELY DERIVED.
3. UPS: 15kVA, 208V, 3PH. FURNISH WITH STATIC BYPASS
SWITCH AND EXTERNAL MAINTENANCE BYPASS.
4. 240/120V, 125A, 1-PHASE ATS WITH SWITCHED
NEUTRAL, 3-POLE. "SERVICE ENTRANCE" RATED WITH
MAINTENANCE BYPASS ISOLATION. BOTH SYSTEMS
SHALL BE SEPARATELY DERIVED.
5. 240/120V, 70A, 1-PHASE ATS WITH SWITCHED NEUTRAL,
3-POLE, NEMA-4X. "SERVICE ENTRANCE" RATED
WITH MAINTENANCE BYPASS ISOLATION. BOTH
SYSTEMS SHALL BE SEPARATELY DERIVED.
6. DISCONNECT SWITCH: 200A, 2P, DUAL-LOCK, NEMA-4X.
LABEL "SITE LIGHTS".
7. FEEDER PROVIDED AND INSTALLED BY UTILITY
BEYOND 5FT. OF SERVICE ENTRANCE.
8. FEEDER PROVIDED AND INSTALLED BY ELECTRICAL
CONTRACTOR WITHIN 5FT OF SERVICE ENTRANCE.
9. UPS: 32kVA, 240V, 1PH. FURNISH WITH STATIC BYPASS
SWITCH AND EXTERNAL MAINTENANCE BYPASS.
10. UPS: 12kVA SCALABLE TO 16kVA, 208V, 1PH. FURNISH
WITH STATIC BYPASS SWITCH AND EXTERNAL
MAINTENANCE BYPASS.
11. PRE-FAB OVERWATCH BUILDING PANELBOARD:
60A, 240/120V, 1-PHASE, MCB, 12-POLE.
FURNISH WITH (8) - 20A/1P, (1) - 20A/2P,
AND (1) - 30A/2P CIRCUIT BREAKER.
12. CONNECT SITE LIGHTING. BRANCH CIRCUITING
SHALL BE REVIEWED BY GA POWER PRIOR TO
INSTALLATION.
13. CONNECT PRE-FAB GUARDBOOTH PANELBOARD
(FURNISHED WITH GUARDBOOTH). PANELBOARD
SHALL NOT HAVE NEUTRAL-GROUND BOND.
14. HOMERUN FOR CT. SEE PANEL SCHEDULE FOR
CIRCUITS TO BE MONITORED.
15. DUAL RATED FOR LIGHTNING PROTECTION.
16. NOT USED.
17. ENCLOSURE BOND.
18. INVERTER: 240/120V, 1PH, 12kW, 10 MIN. BACKUP.
19. CONNECT ACTIVE VEHICLE BARRIER AND ALL
ASSOCIATED EQUIPMENT TO OVERWATCH
PANELBOARD PER MANUFACTURER'S
SPECIFICATIONS. CONTRACTOR SHALL SUBMIT
PANELBOARD SCHEDULE TO ENGINEER ON RECORD
FOR REVIEW PRIOR TO INSTALLATION.
20. CONDUIT AND WIRE PER MANUFACTURER'S
SPECIFICATIONS FOR CONNECTION OF ACTIVE
VEHICLE BARRIER.
21. CONNECT REMOTE MONITORING PANEL VIA 1"C.
22. REMOTE GENERATOR MONITORING PANEL. LOCATED
IN GATEHOUSE.
23. REMOTE (HMI) UPS MONITORING PANEL. LOCATED IN
GATEHOUSE.
24. 240/120V, 200A, 1-PHASE ATS WITH SWITCHED
NEUTRAL, 3-POLE. "SERVICE ENTRANCE" RATED WITH
MAINTENANCE BYPASS ISOLATION. BOTH SYSTEMS
SHALL BE SEPARATELY DERIVED.
25. DISCONNECT SWITCH: 30A, 2P, DUAL-LOCK, NEMA-4X.
LABEL "SITE LIGHTS".
26. SITE LIGHTING FIXTURE AT ACTIVE VEHICLE BARRIER.
27. REMOTE GENERATOR MONITORING PANEL. LOCATED
IN COMMUNICATIONS SHELTER.
28. SERVICE ENTRANCE POINT.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
A W N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B M
IT
TE
D B
Y:
SI
ZE
C H
E C
KE
D B
Y:
AN
S I
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E :
C O
N
TR
AC
T
N O
SO
L I
C
IT
AT
IO
N N
O
C
AT
EG
O
R Y
C O
D E:
1 2 3 4 5
A
FO
R
T G
O R
D O
N , G
EO
R
G
IA
AC
C
ES
S
C O
N
TR
O L
PO
IN
T
FY
8, P N
SA
VA
N
N
AH
D
IS
TR
IC
T
SA
VA
N
N
AH
, G
EO
R G
IA
AE
C
O M
S
ER
VI
C
ES
, I
N C
S J
EF
FE
R
SO
N S
T
ST
E
R
O
AN
O
KE
V A
1-
/3
1/
7 8 9 10
B
C
D
E
F
G
BG
M
1-
-0
W
2H N
-1 8-
R -3
E-601
EL
EC
TR
IC
AL
O
N E
L I N
E D
I A G
R A M
M B
M V
M B
ISSUED FOR CONSTRUCTION
* REFER TO PANELBOARD SCHEDULES FOR CIRCUIT BREAKER SIZES AND REQUIREMENTS.
M
AR
K
DE
SC
RI
PT
IO
N
DA
TE
RE
VI
SE
D
IN
A
CC
O
RD
AN
CE
W
IT
H
AM
EN
DM
EN
T
3/
/1
1 1
| Sheets |
| A-301 - BUILDING SECTIONS |
| A-602.pdf |
| Sheets |
| A-602 - DOOR AND WINDOW SCHEDULES |
| A-801.pdf |
| Sheets |
| A-801 - REFLECTED CEILING PLANS |
| E-002.pdf |
| Sheets |
| E-002 - ELECTRICAL LEGEND |
| E-111 - SYSTEMS IDCC FLOOR PLAN |
| E-601 - ELECTRICAL ONE LINE DIAGRAM |
| E-111.pdf |
| Sheets |
| E-002 - ELECTRICAL LEGEND |
| E-111 - SYSTEMS IDCC FLOOR PLAN |
| E-601 - ELECTRICAL ONE LINE DIAGRAM |
| E-601.pdf |
| Sheets |
| E-002 - ELECTRICAL LEGEND |
| E-111 - SYSTEMS IDCC FLOOR PLAN |
| E-601 - ELECTRICAL ONE LINE DIAGRAM |
File details come from the government source that posted it.