B.08.03 Amendment 0003 Sanem Luxembourg - Micropile Information.pdf

PDF 578 KB Posted

Attached to
Request for Proposal (RFP) for Project: Construct Deployable Airbase Systems – Facilities, Equipment, and Vehicles (DABS/FEV) Storage Complex at Sanem, Luxembourg
Solicitation number
W912GB23R0009
Issued by

About this file

This document contains a request for proposal for construction services and supporting details. The U.S. Army Corps of Engineers seeks to construct a Deployable Airbase Systems-Facilities, Equipment, and Vehicle storage complex at Sanem, Luxembourg to house vehicles, shipping containers, equipment pallets, and refueling tanker trucks. The facilities will include three single-story warehouses of varying sizes, supporting facilities, utilities, pavements, site improvements, and information systems. The construction will also include humidity-controlled warehouses, a general purpose warehouse, and a refueling vehicle maintenance shop. Fire alarm, heat and smoke detection, door monitoring, electrical load shedding, lightning and overvoltage protection systems will be installed. The document provides pre-design load information and specifications for micropiles to support the various structures. Interested offerors should contact the points of contact to obtain the full set of contract drawings.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

18/027 25/02/2023

Length

TENSION COMPRESSION

Unit kN kN mm mm mm m d a D = d+a BUILDING 1 Waterpressure 937,00 127,00 50,00 177,00 11,00

Central column 470,00 100,00 50,00 150,00 8,00 Central column 470,00 100,00 50,00 150,00 11,00 Fondationslab (Level -1: storage) 1285,00 127,00 50,00 177,00 14,00 Fondationslab (Level 0: truck circulation) 920,00 100,00 50,00 150,00 12,50

BUILDING 2 Fondationslab (Level 0): Type 1 450,00 70,00 50,00 120,00 8,00 Fondationslab (Level 0): Type 2 600,00 70,00 50,00 120,00 10,50 Foundation type 4 (Level -1) 965,00 100,00 50,00 150,00 13,00

BUILDING 3 0,00 0,00

WATERTANK 636,00 127,00 50,00 177,00 9,50

Important: number of micropiles and final design to be done by the bidder

Predesign Load Diameter max. load per micropile

Additional information for micropiles

Micropiles_loads
Dywidag_Geotechnische_Systeme_MIRI