This document includes plumbing standard details and a related federal contract opportunity for construction of storage facilities. The standard details provide specifications for plumbing fixtures and connections required for restrooms, mop sinks, and other plumbing systems. Fixtures include water closets, urinals, lavatories, electric water coolers, floor drains, trench drains, equipment drains, cleanouts, and hose bibs. Specifications cover fixture types, sizes, connections, and accessories. The related federal contract opportunity is a request for proposal to construct three warehouses, a refueling vehicle shop, and supporting facilities at Sanem, Luxembourg for storage of deployable airbase systems equipment. The storage complex will include humidity-controlled and general purpose warehouses to accommodate vehicles, containers, and refueling trucks. Supporting facilities will provide utilities, pavements, site improvements, and information systems. The deadline to submit proposals was not provided.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
1 3 5 7 9
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10
F
D
B
P-503
P L U
M B
IN
G
S T
A N
D A
R D
D E
T A
IL
S
I
II
S a n e m
L u x e m b o u rg
E U
R O
P E
D
IS
T R
IC
T
A P
O A
E
C D
M S
M
IT
H F
E D
E R
A L S
E R
V
IC
E S
E U
R O
P E
D A
R M
S T
A E
D T
E R
S T
R
B
IC
K
E N
B A
C H
G
E R
M A
N Y
ID
J M
E
IN
IG
C J O
H N
S O
N
S T
A S
C A
R E
L L A
M A
R C
H
W G
B -2
-F
-0
W G
B -1
-D
-0
C O
R R
E C
T E
D F
IN
A
L S
U B
M
IT
T A
L
E C
A O
S D
A B
S S to ra g e
L U
X E
P
Ø1500
Ø1720
FUEL OIL TANK
TANK
TERMINAL
BOX
PLUMBING FIXTURE CONNECTION SCHEDULE
TAG NO. LOCATION FIXTURE TYPE DESCRIPTION
WASTE
(mm) MIN.
VENT
(mm) MIN.
TRAP
(mm) MIN.
CW
(mm) MIN.
HW
(mm) MIN.
NOTES
WC
(REFER TO
DRAWINGS)
WATER CLOSET
(WALL MOUNT,
FLUSH VALVE)
WATER CLOSET: VITREOUS CHINA, WALL MOUNTED, BACK
OUTLET, ELONGATED BOWL, 1.28 GALLON SIPHON JET
FLUSHING WITH 1 ½-INCH TOP SPUD. PROVIDE WITH
FIXTURE CARRIER.
100 50 N/A 40 N/A
ADA
ACCESSIBLE
FLUSH VALVE: 4.85 LITER PER FLUSH MANUAL FLUSH
VALVE WITH VACUUM BREAKER, SCREWDRIVER ANGLE
STOP AND CHROME PLATED FLUSH CONNECTION;
SEAT: WHITE SOLID PLASTIC, EXTENDED BACK, OPEN
FRONT AND LESS COVER WITH CHECK HINGE
UR
(REFER TO
DRAWINGS)
URINAL
URINAL: VITREOUS CHINA WALL HUNG WASHOUT URINAL
WITH INTEGRAL TRAP AND CLEANOUT PLUG, EXTENDED
SHIELDS, FLUSHING RIM, TOP SPUD WATER CONNECTION;
AND BACK OUTLET WASTE CONNECTION. PROVIDE WITH
FIXTURE CARRIER.
50 40 N/A 20 N/A
ADA
ACCESSIBLE
FLUSH VALVE: 1.9 LITER PER FLUSH, MANUAL FLUSH VALVE
WITH VACUUM BREAKER, SCREWDRIVER ANGLE STOP AND
CHROME PLATED FLUSH CONNECTION.
LAV
(REFER TO
DRAWINGS)
LAVATORY
(WALL MOUNT)
LAVATORY: VITREOUS CHINA, RECTANGULAR BASIN WITH
BACK, ANTI-SPLASH RIM, FRONT OVERFLOW, TWO SOAP
DEPRESSIONS, PUNCHED FOR CONCEALED ARM
BRACKETS. PROVIDE WITH FIXTURE CARRIER.
32 32 32 15 15
ADA
ACCESSIBLE
FAUCET: 1.9 LPM, SINGLE CONTROL CENTERSET
LAVATORY FITTING SHALL FEATURE A CHROME PLATED,
CAST BRASS BODY WITH METAL HANDLE; 1/2-INCH MALE
THREADED BRASS INLET SHANKS; WASHERLESS CERAMIC
DISC VALVE CARTRIDGE WITH INTEGRAL HOT LIMIT SAFETY
STOP.
DRAIN:ADA COMPLIANT, CHROME PLATED BRASS, OFFSET
TAILPIECE WITH GRID STRAINER;
SUPPLY KIT: LEAD FREE CHROME PLATED BRASS SUPPLY
STOP VALVES WITH FULL TURN BRASS STEM. NO PLASTIC.
CHROME PLATED RISERS AND SHALLOW BRASS
ESCUTCHEON.
P-TRAP: ADJUSTABLE CHROME-PLATED CAST BRASS
ONE-PIECE P-TRAP WITH CHROME PLATED CLEANOUT
PLUG AND ESCUTCHEON PLATE.
MS
(REFER TO
DRAWINGS)
MOP SINK
SINK BASIN: PRECAST TERRAZZO UNIT WITH STAINLESS
STEEL PROTECTIVE CAPS ON EXPOSED SIDES; COLOR
SHALL BE BLACK AND WHITE WITH MARBLE CHIPS CAST IN
WHITE PORTLAND CEMENT;
80 50 80 20 20 -
FAUCET: 7.6 LPM (MAX) FLOW; POLISHED CHROME PLATED
CAST BRASS SERVICE SINK FAUCET WITH HOT/COLD
INDEXED QUARTER TURN LEVER HANDLES, 20mm
THREADED SPOUT, PAIL HOOK, VACUUM BREAKER, WALL
BRACE, HOSE, HOSE BRACKET, AND MOP HANGER.
EWC-1
(REFER TO
DRAWINGS)
ELECTRIC
WATER
COOLER
FOUNTAIN: TWO-LEVEL, LEAD-FREE, SELF-CONTAINED,
WALL MOUNTED ELECTRIC REFRIGERATED WATER
COOLER. WATER COOLER DELIVERY SHALL BE 30.0 LPH OF
10 DEGREE C DRINKING WATER BASED ON 32 DEGREE C
INLET WATER. 230V/1PH/50HZ ELECTRICAL SERVICE.
40 32 40 15 N/A
TWO-LEVEL;
ADA
ACCESSIBLE
P-TRAP: ADJUSTABLE CHROME-PLATED CAST BRASS
ONE-PIECE P-TRAP WITH CHROME PLATED CLEANOUT
PLUG AND ESCUTCHEON PLATE
FD-1
(REFER TO
DRAWINGS)
FLOOR DRAIN
DRAIN: HEAVY DUTY CAST IRON SLOTTED GRATING, CAST
IRON BODY WITH BOTTOM OUTLET, SEEPAGE PAN,
COMBINATION MEMBRANE FLASHING CLAMP, ANTI TILT
FRAME, SEDIMENT BUCKET. MINIMUM GRATING FREE OPEN
AREA OF 0.032 SQ. METERS. MINIMUM CLASS D LOAD
RATED GRATING PER EN1433.
(SEE PLANS) (SEE PLANS)
(SEE
PLANS)
N/A N/A
HEAVY DUTY
FLOOR DRAIN
IN EQUIPMENT
AREA
FD-2
(REFER TO
DRAWINGS)
FLOOR DRAIN
DRAIN: LIGHT DUTY POLISHED NICKEL BRONZE STRAINER,
CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION
MEMBRANE CLAMP, ADJUSTABLE COLLAR WITH SEEPAGE
HOLES.
(SEE PLANS) (SEE PLANS)
(SEE
PLANS)
N/A N/A
LIGHT DUTY
FLOOR DRAIN
IN FINISHED
SPACES
TD
(REFER TO
DRAWINGS)
MODULAR
TRENCH DRAIN
PREFABRICATED, PRESLOPED (0.65% MINIMUM), MODULAR
TRENCH DRAIN SYSTEM. POLYMER CONCRETE TRENCH
SECTIONS. PROVIDE WITH END CAPS AS REQUIRED.
STAINLESS STEEL GRATING WITH HOLD DOWN CLIPS.
MINIMUM CLASS E LOAD RATED GRATING PER EN1433.
(SEE PLANS) (SEE PLANS)
(SEE
PLANS)
N/A N/A -
ED
(REFER TO
DRAWINGS)
EQUIPMENT
DRAIN
DRAIN: HEAVY DUTY CAST IRON SLOTTED GRATING, CAST
IRON BODY WITH BOTTOM OUTLET, SEEPAGE PAN,
COMBINATION MEMBRANE FLASHING CLAMP, ANTI TILT
FRAME, SEDIMENT BUCKET. PROVIDE WITH REMOVABLE
FUNNEL.
(SEE PLANS) (SEE PLANS)
(SEE
PLANS)
N/A N/A -
ECO
(REFER TO
DRAWINGS)
EXTERIOR
FLOOR
CLEANOUT
ACCESS COVER: DUCTILE IRON ACCESS HOUSING WITH
PAVEMENT ANCHOR RINGS AND MINIMUM CLASS E LOAD
RATED COVER PER EN1433.
PROVIDE SEPARATE BRONZE CLEANOUT PLUG AND CAST
IRON FERRULE.
(SEE PLANS)
NA NA NA NA -
FCO-1
(REFER TO
DRAWINGS)
FLOOR
CLEANOUT
HEAVY DUTY CAST IRON CLEANOUT HOUSING AND COVER
WITH ADJUSTABLE LEVEL TOP. MINIMUM CLASS E LOAD
RATED COVER PER EN1433. PROVIDE WITH BRONZE PLUG.
(SEE PLANS)
NA N/A N/A N/A
HEAVY DUTY
FLOOR
CLEANOUT
IN EQUIPMENT
AREAS
FCO-2
(REFER TO
DRAWINGS)
FLOOR
CLEANOUT
LIGHT DUTY POLISHED BRONZE CLEANOUT HOUSING AND
COVER WITH ADJUSTABLE LEVEL TOP. PROVIDE WITH
BRONZE PLUG.
(SEE PLANS)
NA N/A N/A N/A
LIGHT DUTY
FLOOR
CLEANOUT
IN FINISHED
SPACES
WCO
(REFER TO
DRAWINGS)
WALL
CLEANOUT
CONCEALED CLEANOUT TEE WITH BRONZE PLUG AND
ROUND POLISHED CHROME PLATED ACCESS COVER.
(SEE PLANS)
NA N/A N/A N/A
TP-1
(REFER TO
DRAWINGS)
TRAP PRIMER
ELECTRONIC TRAP PRIMER UNIT INCLUDING ADJUSTABLE
TIMER, ELECTRIC VALVE, AND SURFACE MOUNTED
ENCLOSURE. PROVIDE WITH DISTRIBUTION UNIT CAPABLE
OF SERVING THE INDICATED NUMBER OF FLOOR DRAINS.
230V/1PH/50HZ.
N/A N/A N/A 20 N/A
TRAP PRIMER
(ELECTRONIC)
TP-2
(REFER TO
DRAWINGS)
TRAP PRIMER
MECHANICAL TRAP PRIMER UNIT. INSTALL CLOSE TO
WATER CLOSET FLUSH VALVE CONNECTION PER TRAP
PRIMER MANUFACTURER INSTRUCTIONS. PROVIDE WITH
DISTRIBUTION UNIT TO SERVE UP TO 4 FLOOR DRAINS.
N/A N/A N/A 20 N/A
TRAP PRIMER
(MECHANICAL)
WHA
(REFER TO
DRAWINGS)
WATER
HAMMER
ARRESTORS
PISTON OR DIAPHRAGM TYPE WATER HAMMER ARRESTOR
WITH PRECHARGED SEALED HOUSING. SIZE PER
MANUFACTURER INSTRUCTIONS. N/A N/A N/A 20 N/A
PROVIDE WITH
ACCESS
DOORS FOR
CONCEALED
LOCATIONS.
HB
(REFER TO
DRAWINGS)
HOSE BIBB
VALVE: BRONZE BODY, STRAIGHT PATTERN GLOBE VALVE
WITH MANUAL HANDWHEEL AND HOSE THREAD OUTLET
AND CAP. PROVIDE WITH ATMOSPHERIC VACUUM
BREAKER.
HOSE: 20mm HEAVY DUTY MULTIPLY EPDM RUBBER HOSE
WITH BRASS THREAD HOSE CONNECTIONS.
HOSE RACK: GALVANIZED STEEL HOSE RACK SUITABLE
FOR AT LEAST 15M HOSE LENGTH.
N/A N/A N/A 20 N/A
SUPPLY FROM
PROTECTED
WATER
SECTION A-A
HEAVY DUTY GRATING
FINISH FLOOR
SLOPED TO TRENCH DRAIN. REFER TO
STRUCTURAL PLANS FOR FINISH FLOOR
ELEVATIONS AND SLOPES.
DRAIN PIPE DOWN
THROUGH SLAB
BOTTOM OUTLET DRAIN PIPE
CONNECTION FROM LOWEST
TRENCH SECTION
THICKENED SLAB.
REFER TO STRUCTURAL
SHEETS FOR DETAILS
DETAIL A
PREFABRICATED, PRE-SLOPED TRENCH DRAIN
SECTION CAST INTO CONCRETE SLAB. ANCHOR INTO
CONCRETE PER MANUFACTURER INSTRUCTIONS.
SEAL BETWEEN SECTION PER
TRENCH MANUFACTURER
INSTRUCTIONS
A
A
GRATING HOLD DOWN SYSTEM
TRENCH DRAIN END CAP