W912EP20R0039-Amendment 0003.pdf

PDF 13 MB Posted

Attached to
Fort Buchanan Family Housing Replacement Fort Buchanan-Guaynabo, Puerto Rico
Solicitation number
W912EP20R0039
Issued by

About this file

This document provides details on a federal contract solicitation for family housing replacement at Fort Buchanan in Puerto Rico. The U.S. Army Corps of Engineers is soliciting proposals to demolish 27 existing family housing units, construct 26 new units, and install supporting site utilities and infrastructure. Interested vendors must register on SAM.gov to receive amendments and be eligible for award. A pre-proposal teleconference will be held on October 27, 2020, and initial proposals are due November 6, 2020. The project value is estimated between $10-25 million. The NAICS code is 236115 for new single-family housing construction, with a size standard of $39.5 million. The period of performance is anticipated to be 814 calendar days from notice to proceed.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-8 4

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

1. CONTRACT ID CODE PAGE OF PAGES

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 16-Mar-2020

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X

X 9B. DATED (SEE ITEM 11)

7-October-2020

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION

NO. W912EP20R0039

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

W912EP20R0039 FORT BUCHANAN FAMILY HOUSING REPLACEMENT FORT BUCHANAN , PUERTO RICO

A. See Continuation Sheet for Amendment details.

B. The proposal due date has changed from 12 November 2020 2:00 pm to 16 November 2020 10:00 am.

C. Bidder Inquiry submittal deadline has changed from 1 November 2020 to 9 November 2020.

D. All other Terms and Conditions remain unchanged.

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO.

5. PROJECT NO.(If applicable)

6. ISSUED BY CODE

USA ENGINEER DISTRICT, JACKSONVILLE

CONTRACTING DIVISION

701 SAN MARCO BLVD

JACKSONVILLE FL 32207-8175

W912EP 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

3. EFFECTIVE DATE

05-Nov-2020

W912EP20R0039

X

Amendment 0003

SF 30 CONTINUATION SHEET

Fort Buchanan Family Housing Replacement Fort Buchanan, Guaynabo, Puerto Rico

W912EP20R0039 Amendment 0003

SUMMARY OF CHANGES

1. SPECIFICATIONS:

The text changes have been updated with additions noted by underlined text and deletions noted by line/cross-outs, and pertain only to changes made by this amendment. The entire section is replaced if there is any change. The Project Table of Contents and Submittal Register are replaced without underlines and cross-outs if there are changes to these documents. New sections are added without underlines and cross-outs.

DELETE SF 1442 and REPLACED with the attached updated SF 1442.

DELETE Section 00010A and REPLACED with the attached updated Section 00010A.

DELETE LEED Project Checklist in Section 01 33 29 Attachment and REPLACE with the attached LEED Project Checklist in Section 01 33 29 Attachment.

DELETE Section 31 31 16.19.13 ADD attached Section 31 31 16.13

2. DRAWINGS:

DELETE Sheet A-003 and REPLACE with the attached Sheet A-003.

DELETE Sheet A-004 and REPLACE with the attached Sheet A-004.

DELETE Sheet A-102B and REPLACE with the attached Sheet A-102B.

DELETE Sheet A-301A and REPLACE with the attached Sheet A-301A.

DELETE Sheet A-302B and REPLACE with the attached Sheet A-302B.

DELETE Sheet A-303C and REPLACE with the attached Sheet A-303C.

DELETE Sheet A-321A and REPLACE with the attached Sheet A-321A.

DELETE Sheet A-402B and REPLACE with the attached Sheet A-402B.

DELETE Sheet A-402C and REPLACE with the attached Sheet A-402C.

DELETE Sheet A-501 and REPLACE with the attached Sheet A-501.

DELETE Sheet A-601A and REPLACE with the attached Sheet A-601A.

DELETE Sheet A-601B and REPLACE with the attached Sheet A-601B.

DELETE Sheet A-601C and REPLACE with the attached Sheet A-601C.

DELETE Sheet A-602 and REPLACE with the attached Sheet A-602.

DELETE Sheet C-003 and REPLACE with the attached Sheet C-003.

DELETE Sheet C-004 and REPLACE with the attached Sheet C-004.

DELETE Sheet CS501 and REPLACE with the attached Sheet CS501.

DELETE Sheet E-601 and REPLACE with the attached Sheet E-601.

DELETE Sheet ES101 and REPLACE with the attached Sheet ES101.

DELETE Sheet ES102 and REPLACE with the attached Sheet ES102.

DELETE Sheet ES103 and REPLACE with the attached Sheet ES103.

DELETE Sheet ES104 and REPLACE with the attached Sheet ES104.

DELETE Sheet ES601 and REPLACE with the attached Sheet ES601.

DELETE Sheet L-108 and REPLACE with the attached Sheet L-108.

DELETE Sheet P-001 and REPLACE with the attached Sheet P-001.

(End of Summary of Changes)

SOLICITATION, OFFER,

AND AWARD

(Construction, Alteration, or Repair)

1. SOLICITATION NO.

W912EP20R0039

2. TYPE OF SOLICITATION

SEALED BID (IFB)

X NEGOTIATED (RFP)

3. DATE ISSUED

7-Oct-2020

PAGE OF PAGES

IMPORTANT - The "offer" section on the reverse must be fully completed by offeror.

4. CONTRACT NO. 5. REQUISITION/PURCHASE REQUEST NO. 6. PROJECT NO.

7. ISSUED BY CODE W912EP 8. ADDRESS OFFER TO (If Other Than Item 7) CODE

USA ENGINEER DISTRICT, JACKSONVILLE

CONTRACTING DIVISION

701 SAN MARCO BLVD

JACKSONVILLE FL 32207-8175

TEL: FAX:

See Item 7

TEL: FAX:

9. FOR INFORMATION

CALL:

A. NAME

WILLIAM WALLACE

B. TELEPHONE NO. (Include area code) (NO COLLECT CALLS)

SOLICITATION

NOTE: In sealed bid solicitations "offer" and "offeror" mean "bid" and "bidder".

(Title, identifying no., date): 10. THE GOVERNMENT REQUIRES PERFORMANCE OF THE WORK DESCRIBED IN THESE

DOCUMENTS

FORT BUCHANAN FAMILY HOUSING REPLACEMENT FORT BUCHANAN , PUERTO RICO

DESCRIPTION OF WORK: REFER TO SECTION 01 11 00 FOR COMPLETE PROJECT DESCRIPTION

DRAWINGS: SEE DFARS CLAUSE 252.236 7001, IN SECTION 00700.

MAGNITUDE OF CONSTRUCTION IS BETWEEN $10,000,000 AND $25,000,000.

THIS IS AN UNRESTRICTED SOLICITATION AND ALL RESPONSIBLE OFFERORS ARE ENCOURAGED TO PARTICIPATE.

THE NAICS CODE IS 236115 AND THE SMALL BUSINESS SIZE STANDARD IS $39,500,000.00.

***BLOCK 11 - SEE SECTION 00700, CLAUSE 52.211-10 FOR PERIOD OF PERFORMANCE

A SITE VISIT WILL BE HELD SEE FAR CLAUSE 52.236-27 IN SECTION 00100.

YOU MUST BE REGISTERED IN SAM IN ORDER TO RECEIVE AN AWARD FROM THIS SOLICITATION THE SAM WEBSITE IS

LOCATED AT WWW.SAM.GOV.

11. The Contractor shall begin perf ormance within calendar days and complete it within calendar days after receiving award notice to proceed. This performance period is mandatory, negotiable. (See _S_E_C_T_I_O_N 0_0_700 .)

12 A. THE CONTRACTOR MUST FURNISH ANY REQUIRED PERFORMANCE AND PAYMENT BONDS?

(If "YES," indicate within how many calendar days after award in Item 12B.)

X YES NO

12B. CALENDAR DAYS

13. ADDITIONAL SOLICITATION REQUIREMENTS:

A. copies to perform the work required are due at the place specif ied in Item 8 by 0_2_:_0_0_P_M (hour)

(date). If this is a sealed bid solicitation, offers must be publicly opened at that time. Sealed envelopes containing offers shall be marked to show the offeror's name and address, the solicitation number, and the date and time offers are due.

B. An offer guarantee X is, is not required.

C. All of fers are subject to the (1) work requirements, and (2) other provisions and clauses incorporated in the solicitation in full text or by reference.

D. Of fers providing less than 90 calendar days for Government acceptance after the date offers are due will not be considered and will be rejected.

NSN 7540-01-155-3212 1442-101 STANDARD FORM 1442 (REV. 4-85)

Prescribed by GSA

FAR (48 CFR) 53.236-1(e)

Sealed offers in original and 0

_______30

X X

________814 local time 6___ Nov 2020 l_______16 10:00 am

Amendment 0003 http://www.sam.gov/ http://www.sam.gov/

SOLICITATION, OFFER, AND AWARD (Continued) (Construction, Alteration, or Repair)

14. NAME AND ADDRESS OFOFFEROR (Include ZIP Code)

OFFER (Must be fully completed by offeror)

15. TELEPHONE NO. (Include area code)

16. REMITTANCE ADDRESS (Include only if different than Item14)

See Item 14

CODE FACILITY CODE

17. The offeror agrees to perform the work required at the prices specified below in strict accordance with the terms of this solicitation, if this offer is accepted by the Government in writing w thin calendar days after the date offers are due. (Insert any number equal to or greater than the minimum requirements stated in Item 13D. Failure to insert any number means the offeror accepts the minimum in Item 13D.)

AMOUNTS SEE SCHEDULE OFPRICES

18. The offeror agrees to furnish any required performance and payment bonds.

19. ACKNOWLEDGMENT OF AMENDMENTS

(The offeror acknowledges receipt of amendments to the solicitation -- give number and date of each)

AMENDMENT NO.

DATE

20A. NAME AND TITLE OF PERSON AUTHORIZED TO SIGN

OFFER (Type or print)

20B. SIGNATURE 20C. OFFER DATE

21. ITEMS ACCEPTED:

AWARD (To be completed by Government)

22. AMOUNT 23. ACCOUNTING AND APPROPRIATIONDATA

24. SUBMIT INVOICES TO ADDRESS SHOWNIN

(4 copies unless otherwise specified)

ITEM 25. OTHER THAN FULL AND OPEN COMPETITION PURSUANT TO

10 U.S.C. 2304(c) 41 U.S.C. 253(c)

26. ADMINISTEREDBY CODE 27. PAYMENT WILL BE MADEBY: CODE

CONTRACTING OFFICER WILL COMPLETE ITEM 28 OR 29 AS APPLICABLE

28. NEGOTIATED AGREEMENT (Contractor is required to sign this 29. AWARD (Contractor is not required to sign this document.)

document and return _ copies to issuing office.) Contractor agrees to furnish and deliver all items or perform all work, requisitions identified on this form and any continuation sheets f or the consideration stated in this contract. The rights and obligations of the parties to this contract shall be governed by (a) this contract award, (b) the solicitation, and (c) the clauses, representations, certifications, and specifications or incorporated by reference in or attached to this contract.

30A. NAME AND TITLE OF CONTRACTOR OR PERSON AUTHORIZED

Your offer on this solicitation, is hereby accepted as to the items listed. This award con-summates the contract, which consists of (a) the Government solicitation and y our offer, and (b) this contract award. No further contractual document is necessary.

31A. NAME OF CONTRACTING OFFICER (Type or print) TO SIGN (Type or print)

30B. SIGNATURE 30C. DATE

TEL: EMAIL:

31B. UNITED STATES OF AMERICA 31C. AWARD DATE

BY

NSN 7540-01-155-3212 STANDARD FORM 1442 BACK (REV. 4-85)

SECTION 00010A

LINE ITEMS AND PRICING SCHEDULE

FORT BUCHANAN FAMILY HOUSING REPLACEMENT

FORT BUCHANAN, PUERTO RICO

NOTES

(1) OFFER MUST PRICE ALL LINE ITEMS.

(2) ALL SPECIFICATION REFERENCES TO LUMP SUM SHALL APPLY TO LINE ITEMS INDICATING JOB AS THE UNIT.

(3) THE JOB PRICE AND PAYMENT MADE FOR EACH ITEM LISTED SHALL CONSTITUTE FULL COMPENSATION FOR FURNISHING ALL PLANT, LABOR, MATERIALS AND EQUIPMENT, AND PERFORMING ANY ASSOCIATED CONTRACTOR QUALITY CONTROL, ENVIRONMENTAL PROTECTION, MEETING SAFETY REQUIREMENTS, TESTS AND REPORTS, AND FOR PERFORMING ALL WORK REQUIRED FOR WHICH SEPARATE PAYMENT IS NOT OTHERWISE PROVIDED. ALL COSTS FOR ITEMS OF WORK, WHICH ARE NOT SPECIFICALLY MENTIONED TO BE INCLUDED IN A PARTICULAR JOB OR UNIT PRICE PAYMENT ITEM, SHALL BE INCLUDED IN THE

LISTED JOB ITEM AND MUST CLOSELY ASSOCIATED WITH THE WORK INVOLVED.

(6) THE AMOUNTS INCLUDED FOR THE CLINS RELATED TO MUNICIPAL TAXES WILL NOT BE CONSIDERED FOR PRICE EVALUATION

OF THE PROPOSALS.

(4) PROGRESS PAYMENTS FOR JOB CLINS WILL BE MADE IN ACCORDANCE WITH THE PAYMENTS UNDER FIXED-PRICE CONSTRUCTION CONTRACTS CLAUSE OF SECTION 00700 CONTRACT CLAUSES. SUBMIT A LIST OF PAY ACTIVITIES, (SCHEDULE OF VALUES) TO BREAKDOWN BID FOR EACH JOB CLIN. SUBMIT THE SCHEDULE OF VALUES FOR GOVERNMENT APPROVAL WITH THE BASELINE SCHEDULE SUBMITTAL (SEE SECTION 01 32 01 PROJECT SCHEDULE). AN UNBALANCED SCHEDULE OF VALUES AND PAY

ACTIVITY SCHEDULE WILL BE RETURNED FOR REVISION.

(10) PRICE FOR BID OPTION 7 SHALL BE GOOD FOR 365 CALENDAR DAYS FROM NOTICE TO PROCEED (NTP).

(5) THE CONTRACT PRICE WILL BE ADJUSTED TO COMPENSATE THE CONTRACTOR FOR THE AMOUNT OF CONSTRUCTION TAXES.

NO MARK-UPS WILL BE ALLOWED IN THIS LINE ITEM. THE CONTRACTOR WILL BE PAID ON THE BASIS OF PROOF OF PAYMENT

FROM THE APPROPRIATE COMMONWEALTH OF PUERTO RICO MUNICIPAL AUTHORITIES.

(8) LINE ITEMS 0006 THROUGH 0013 INCLUDE ALL REQUIRED WORK TO DELIVER A COMPLETE AND USABLE FACILITY INCLUDING

ASSOCIATED UTILITIES NOT INCLUDED IN LINE ITEM 2.

(7) LINE ITEM 0002 EXCLUDES UTILITY INSTALLATION FOR BID OPTIONS 1 THROUGH 4.

(9) PRICE FOR BID OPTIONS 1 THROUGH 6 SHALL BE GOOD FOR 180 CALENDAR DAYS FROM NOTICE TO PROCEED (NTP).

W912EP20R0039 00010A-2

FORT BUCHANAN FAMILY HOUSING REPLACEMENT

FORT BUCHANAN, PUERTO RICO

LINE ITEM DESCRIPTION QUANTITY UNIT UNIT PRICE TOTAL

0001 DEMOLITION JOB $_______________

0002 LAND DEVELOPMENT JOB $_______________

0003 HOUSING JOB $_______________

0004 RECREATIONAL PARK JOB $_______________

SUBTOTAL BASE (LINE ITEMS 0001 THROUGH 0004) $_______________

0005 MUNICIPAL TAXES JOB $_______________

TOTAL BASE (LINE ITEMS 0001 THROUGH 0005) $_______________

0006 BID OPTION 1 (House 14 Model A.A) JOB $_______________

0007 MUNICIPAL TAXES JOB $_______________

TOTAL BID OPTION 1 (LINE ITEMS 0006 THROUGH 0007) $_______________

0008 BID OPTION 2 (House 15 Model A.A) JOB $_______________

0009 MUNICIPAL TAXES JOB $_______________

TOTAL BID OPTION 2 (LINE ITEMS 0008 THROUGH 0009) $_______________

0010 BID OPTION 3 (House 16 Model A.A) JOB $_______________

0011 MUNICIPAL TAXES JOB $_______________

TOTAL BID OPTION 3 (LINE ITEMS 0010 THROUGH 0011) $_______________

0012 BID OPTION 4 (House 17 Model A.A) JOB $_______________

0013 MUNICIPAL TAXES JOB $_______________

TOTAL BID OPTION 4 (LINE ITEMS 0012 THROUGH 0013) $_______________

0014 BID OPTION 5 (North Buffer Trees) JOB $_______________

0015 MUNICIPAL TAXES JOB $_______________

TOTAL BID OPTION 5 (LINE ITEMS 0014 THROUGH 0015) $_______________

BID OPTION 6 (PARK TREES, SHRUBS AND GROUND

COVER) JOB $_______________

0017 MUNICIPAL TAXES JOB $_______________

TOTAL BID OPTION 6 (LINE ITEMS 0016 THROUGH 0017) $_______________

0018 BID OPTION 7 - APPLIANCES (KITCHEN, LAUNDRY) JOB $_______________

0019 MUNICIPAL TAXES JOB $_______________

TOTAL BID OPTION 7 (LINE ITEMS 0018 THROUGH 0019) $_______________

TOTAL OPTIONS (LINE ITEMS 0006 THROUGH 0019) $_______________

TOTAL BASE PLUS OPTIONS (LINE ITEMS 0001 THROUGH 0019) $_______________

W912EP20R0039 00010A-1 Amendment 0003

SECTION 00010A, Attachment A

INSTRUCTIONS FOR TECHNICAL INQUIRIES AND QUESTIONS

Technical inquiries and questions relating to this solicitation are to be submitted via Bidder Inquiry in ProjNet at (https://www.projnet.org) No Later Than (NLT) October 26, 2020, End of Day. To submit and review inquiry items, prospective vendors will need to use the Bidder Inquiry Key presented below and follow the instructions listed below the key for access. A prospective vendor who submits a comment /question will receive an acknowledgement of their comment/question via email, followed by an answer to the comment/question after it has been processed by our technical team.

All timely questions and approved answers will be made available through ProjNet.

The Solicitation Number is: W912EP20R0039

The Bidder Inquiry Key is: 2TG5MF 5PDN3J

Specific Instructions for ProjNet Bid Inquiry Access from ProjNet home page:

1. Identify the Agency. This should be marked as USACE.

2. Email. Enter the email address you would like to use for communication.

3. Key. Enter the Bidder Inquiry Key listed above.

4. Click Continue. A page will then open saying that a user account was not found and will ask you to create one using the provided form.

5. Enter your First Name, Last Name, Company, City, State, Phone, Email, Secret Question, Secret

Answer, and Time Zone. Make sure to remember your Secret Question and Answer as they will be used from this point on to access the ProjNet system.

6. Click Add User. Once this is completed you are now registered within ProjNet and are currently logged into the system.

Specific Instructions for Future ProjNet Bid Inquiry Access from ProjNet home page:

1. For future access to ProjNet, you will not be emailed any type of password. You will utilize your Secret Question and Secret Answer to log in.

2. Identify the Agency. This should be marked as USACE.

3. Email. Enter the email address you used to register previously in ProjNet.

4. Key. Enter the Bidder Inquiry Key listed above.

5. Click Continue. A page will then open asking you to enter the answer to your Secret Question.

6. Enter your Secret Answer and click Login. Once this is completed you are now logged into the system.

_________November 1, 2020_____________________

November 9, Project Title: U.S. ARMY FAMILY HOUSING REPLACEMENT

FT. BUCHANAN, GUAYNABO, PUERTO RICO

(3) The contract price will be adjusted to compensate the Contractor for the amount of construction taxes. No mark-ups will be allowed in this line item. The Contractor will be paid on the basis of proof of payment from the appropriate Commonwealth of Puerto Rico or Municipal authorities.

W912EP20R0039 00010A-2 Amendment 0003

LEED v4 for Building Design and Construction: Homes Project Checklist Ft. Buchanan Family Housing Replacement

11/3/2020

Y ? N 2 Credit 2

5 3 7 15 3 Credit Heating & Cooling Distribution Systems 3 Y Prereq Floodplain Avoidance Required 1 1 1 Credit Efficient Domestic Hot Water Equipment 3

2 Credit Lighting 2 0 Credit 15 2 Credit High Efficiency Appliances 2

4 Credit Renewable Energy 4 5 2 1 Credit Site Selection 8

3 Credit 3 5 3 2 Materials and Resources 10 1 1 Credit 2 Y Prereq Certified Tropical Wood Required

2 Credit 2 Y Prereq Durability Management Required 1 Credit Durability Management Verification 1

3 2 2 7 1 1 2 Credit Environmentally Preferable Products 4 Y Prereq Construction Activity Pollution Prevention Required 3 Credit Construction Waste Management 3 Y Prereq No Invasive Plants Required 2 Credit Material Efficient Framing 2 1 1 Credit 2 2 1 Credit 3 5 0 11 Indoor Environmental Quality 16

2 Credit 2 Y Prereq Ventilation Required Y Prereq Combustion Venting Required

6 4 2 Water Efficiency 12 Y Prereq Garage Pollutant Protection Required Y Prereq Water Metering Required Y Prereq Radon-Resistant Construction Required

Y Prereq Air FIltering Required 6 4 2 Credit 12 Y Prereq Environmental Tobacco Smoke Required

Y Prereq Compartmentalization Required 0 Credit 6 3 Credit Enhanced Ventilation 3 0 Credit 4 2 Credit Contaminant Control 2

3 Credit Balancing of Heating and Cooling Distribution Systems 3 25 6 6 Energy and Atmosphere 38 1 Credit Enhanced Compartmentalization 1 Y Prereq Minimum Energy Performance Required 2 Credit Enhanced Combustion Venting 2 Y Prereq Energy Metering Required 2 Credit Enhanced Garage Pollutant Protection 2 Y Prereq Education of the Homeowner, Tenant or Building Manager Required 3 Credit Low Emitting Products 3

Credit 29 5 1 0 Innovation 6 Y Prereq Preliminary Rating Required

2 3 Credit 5 5 Credit Innovation 5 2 Credit Advanced Utility Tracking 2 1 Credit LEED AP Homes 1

1 Credit 1 1 Credit HVAC Start-Up Credentialing 1 3 1 0 Regional Priority 4

1 Credit Regional Priority: Site Selection 1 Y Prereq Home Size Required 1 Credit Regional Priority: Total Water Use 1

3 Credit 3 1 Credit Regional Priority: Material Efficient Framing 1 2 Credit 2 1 Credit Regional Priority: Rainwater Management 1 2 Credit 2 3 Credit 3 57 20 30 TOTALS Possible Points: 110 2 2 Credit 4 Certified: 40 to 49 points, Silver: 50 to 59 points, Gold: 60 to 79 points, Platinum: 80 to 110

Heat Island Reduction

Building Orientation for Passive Solar

Rainwater Management Non-Toxic Pest Control

PERFORMANCE PATH

PERFORMANCE PATH

Total Water Use

Indoor Water Use

Annual Energy Use

Outdoor Water Use

PRESCRIPTIVE PATH

Air Infiltration Envelope Insulation Windows Space Heating & Cooling Equipment

BOTH PATHS

PRESCRIPTIVE PATH

Efficient Hot Water Distribution System

Active Solar Ready Design

Project Name:

Date:

Location and Transportation

Sustainable Sites

LEED for Neighborhood Development Location

PERFORMANCE PATH

PRESCRIPTIVE PATH

Compact Development Community Resources

Integrative Process EA PRESCRIPTIVE PATH (continued)

Access to Transit

Fort Buchanan Family Housing Replacement Fort Buchanan Guaynabo, Puerto Rico

SECTION TABLE OF CONTENTS

DIVISION 31 - EARTHWORK

SECTION 31 31 16.13

CHEMICAL TERMITE CONTROL

08/16

PART 1 GENERAL

1.1 REFERENCES

1.2 ADMINISTRATIVE REQUIREMENTS

1.3 SUBMITTALS

1.4 QUALITY CONTROL

1.4.1 Regulatory Requirements

1.4.2 Qualifications

1.4.3 Safety Requirements

1.5 DELIVERY, STORAGE, AND HANDLING

1.5.1 Delivery

1.5.2 Inspection

1.5.3 Storage

1.5.4 Handling

1.6 SITE CONDITIONS

1.6.1 Soil Moisture

1.6.2 Runoff and Wind Drift

1.7 WARRANTY

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

2.2 MATERIALS

2.2.1 Termiticides

PART 3 EXECUTION

3.1 PREPARATION

3.1.1 Verification

3.1.2 Foundation Exterior

3.1.3 Utilities and Vents

3.1.4 Crawl and Plenum Air Spaces

3.1.5 Application Plan

3.2 APPLICATION

3.2.1 Equipment Calibration and Tank Measurement

3.2.2 Mixing and Application

3.2.2.1 Application Method

3.2.2.1.1 Surface Application

3.2.2.1.2 Rodding and Trenching

3.2.3 Sampling

3.2.4 Vapor Barriers and Waterproof Membranes

3.2.5 Placement of Concrete

3.2.6 Clean Up, Disposal, And Protection

3.2.6.1 Clean Up

3.2.6.2 Disposal of Termiticide

3.3 FIELD QUALITY CONTROL

SECTION 31 31 16.13 Page 1

W912EP20R0039

3.3.1 Verification of Measurement

3.3.2 Inspection

3.3.2.1 Technical Representative

3.4 CLOSEOUT ACTIVITIES

3.5 PROTECTION

3.5.1 Protection of Treated Area

3.5.2 Disturbance of Treated Soils

-- End of Section Table of Contents --

SECTION 31 31 16.13 Page 2

SECTION 31 31 16.13

CHEMICAL TERMITE CONTROL

08/16

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

U.S. DEPARTMENT OF DEFENSE (DOD)

DODI 4150.07 (2019) DOD Pest Management Program

1.2 ADMINISTRATIVE REQUIREMENTS

Coordinate work related to final grades, landscape plantings, foundations, or any other alterations to finished construction which might alter the condition of treated soils with this specification.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-01 Preconstruction Submittals

Termiticide Application Plan ; G

SD-03 Product Data

Termiticides

SD-05 Design Data

Mixing Formulation

SD-06 Test Reports

Soil Moisture

Calibration Test

SD-07 Certificates

Qualifications ; G

Foundation Exterior

Utilities and Vents

SECTION 31 31 16.13 Page 3

Crawl and Plenum Air Spaces

List of Equipment

SD-08 Manufacturer's Instructions

Termiticides

SD-11 Closeout Submittals

Verification of Measurement

Warranty

Pest Management Report

1.4 QUALITY CONTROL

1.4.1 Regulatory Requirements

Comply with DODI 4150.07 for requirements on Contractor's licensing, certification, and record keeping. Maintain daily records using the Pest Management Maintenance Record, DD Form 1532-1, or a computer generated equivalent, and submit copies of records when requested by the Contracting Officer. These forms may be obtained from the main web site:

http://www.dtic.mil/whs/directives/forms/eforms/dd1532-1.pdf

1.4.2 Qualifications

For the application of pesticides, use the services of an applicator whose principal business is pest control. The applicator must be commercially certified in the state where the work is to be performed as required by DODI 4150.07. Termiticide applicators must also be certified in the U.S. Environmental Protection Agency (EPA) pesticide applicator category which includes structural pest control. Submit a copy of the pest control business license and pesticide applicator certificates.

1.4.3 Safety Requirements

Formulate, treat, and dispose of termiticides and their containers in accordance with label directions. Draw water for formulating only from sites designated by the Contracting Officer, and fit the filling hose with a backflow preventer meeting local plumbing codes or standards. Perform filling operations under the direct and continuous observation of a contractor's representative to prevent overflow. Secure pesticides and related materials under lock and key when unattended. Ensure that proper protective clothing and equipment are worn and used during all phases of termiticide application. Dispose of used pesticide containers off Government property.

1.5 DELIVERY, STORAGE, AND HANDLING

1.5.1 Delivery

Deliver termiticide material to the site in the original unopened containers bearing legible labels indicating the EPA registration number, manufacturer's registered uses and in new or otherwise good condition as supplied by the manufacturer or formulator.

SECTION 31 31 16.13 Page 4

1.5.2 Inspection

Inspect termiticides upon arrival at the job site for conformity to type and quality in accordance with paragraph TERMITICIDES. Each label must bear evidence of registration under the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), as amended or under appropriate regulations of the host county. Inspect other materials for conformance with specified requirements. Remove unacceptable materials from the job site.

1.5.3 Storage

Storage of pesticides on the installation will not be permitted unless it is written into the contract.

1.5.4 Handling

Handle and mix termiticides in accordance with the manufacturer's label and SDS, preventing contamination by dirt, water, and organic material.

Protect termiticides from weather elements as recommended by the manufacturer's label and SDS. Spill kits must be maintained on pest control vehicles and must be available at the mixing site. Conduct termiticide mixing in an area with adequate spill containment.

1.6 SITE CONDITIONS

The following site conditions determine the acceptable time of application.

1.6.1 Soil Moisture

Test soils to be treated immediately before application. Test soil moisture content to a minimum depth of 3 inches . The soil moisture must be as recommended by the termiticide manufacturer. Application of the termiticide is not permitted when soil moisture content exceeds manufacturer's recommendations.

1.6.2 Runoff and Wind Drift

Application of termiticide will not be permitted during or immediately following heavy rains, when conditions may allow runoff, or create an environmental hazard or when average wind speed exceeds 10 miles per hour. Termiticide is not permitted to enter water systems, aquifers, or endanger humans or animals.

1.7 WARRANTY

Provide a 5 year written warranty against infestations or reinfestations by subterranean termites of the buildings or building additions constructed under this contract. Include in the warranty annual inspections of the buildings or building additions during the warranty period. If live subterranean termite infestation or subterranean termite damage is discovered during the warranty period, and the soil and building conditions have not been altered in the interim:

a. Retreat the site and perform other treatment as may be necessary for elimination of subterranean termite infestation;

b. Repair damage caused by termite infestation; and

c. Reinspect the building approximately 180 days after the re-treatment.

SECTION 31 31 16.13 Page 5

PART 2 PRODUCTS

2.1 SYSTEM DESCRIPTION

Chemical termite control uses liquid termiticide treatments applied to the soil to form a continuous chemical barrier in the soil around both sides of the foundation. The application can be surface applied or rodded and trenched. This barrier prevents foraging termites from reaching the foundation and piers. Only the soil adjacent to these foundation elements is treated. For slab construction (including foundations, patios and garages), the entire soil (or gravel) surface is treated before the vapor barrier is installed and the slab poured over it. Soil treatment is coordinated with all building activities from foundation construction through final grading of the soil around the building's exterior. In order for the treatment to be effective, the final phase of the application must be done after final grading and sometimes after landscaping is completed so that the treated soil is not disturbed.

2.2 MATERIALS

2.2.1 Termiticides

Provide termiticides currently registered by the EPA or approved for such use by the appropriate agency of the host county and as approved by the Contracting Officer. Select non-repellant termiticides for maximum effectiveness and duration after application. Select a termiticide that is suitable for the soil and climatic conditions at the project site and apply at the highest labeled rate. Submit manufacturer's label and Safety Data Sheet (SDS) for termiticides proposed for use.

PART 3 EXECUTION

3.1 PREPARATION

Eliminate food sources by removing debris from clearing and grubbing and post construction wood scraps such as ground stakes, form boards, and scrap lumber from the site, before termiticide application begins.

3.1.1 Verification

Before work starts, verify that final grades are as indicated and smooth grading has been completed in accordance with Section 31 00 00 EARTHWORK.

Finely grade soil and remove particles larger than 1 inch . Compact soil particles to eliminate soil movement.

3.1.2 Foundation Exterior

If the exterior perimeter treatment is applied when the horizontal barrier is applied it will be damaged or removed before construction is completed. The exterior foundation perimeter treatment will have to occur in phases when any pads, porches, aprons, sidewalks, final grading or landscape planting are simultaneously involved adjacent to the building foundation. This treatment area should be coordinated after all major construction but before any pads, porches, or other items requiring special consideration are poured adjacent to the foundation walls. Submit written verification that final grading, landscape planting and other items adjacent to the foundation will not disturb treatment of the soil on the exterior sides of foundation walls, grade beams, and similar

SECTION 31 31 16.13 Page 6 structures.

3.1.3 Utilities and Vents

Turn off and block HVAC ducts and vents located in treatment area prior to application, to protect people and animals from termiticide. Submit written verification that the HVAC ducts and vents, water and sewer lines, and plumbing have been turned off or blocked prior to applying termiticide.

3.1.4 Crawl and Plenum Air Spaces

Submit written verification that crawl and plenum air spaces have been located and identified prior to applying termiticide.

3.1.5 Application Plan

Prior to commencing application of termiticide, submit a Termiticide Application Plan addressing the following items:

a. proposed sequence of treatment work including dates and times of application

b. termiticide trade name

c. EPA registration number

d. chemical composition

e. concentration of original and diluted material

f. formulation

g. manufacturer's recommended application rates

h. regional requirements

i. application rate of active ingredients

j. method of application

k. area or volume to be treated

l. amount to be applied

m. copy of the pest control business license

n. copy of the pesticide applicator certificates

3.2 APPLICATION

For areas to be treated, establish complete and unbroken vertical and horizontal soil poison barriers between the soil and all portions of the intended structure which may allow termite access to wood and wood related products. Make applications to crawl spaces in accordance with label directions. Applications to crawl space areas that are used as plenum air spaces will not be permitted.

3.2.1 Equipment Calibration and Tank Measurement

Submit a list of equipment to be used. Conduct calibration test on the application equipment to be used immediately prior to commencement of termiticide application. Measure the volume and contents of the application tank. Testing must confirm that the application equipment is operating within the manufacturer's specifications and meets the specified requirements. Submit written certification of the equipment calibration test results within 1 week of testing. Where results from the equipment calibration and tank measurements tests are unsatisfactory, re-treatment will be required.

3.2.2 Mixing and Application

Perform all work related to formulating, mixing, and application in the presence of the Contracting Officer and a DOD certified pesticide

SECTION 31 31 16.13 Page 7 applicator, Pest Management QAE/PAR, or Integrated Pest Management Coordinator. Submit mixing formulation :

a. Quantity of pesticide used.

b. Rate of dispersion.

c. Percent of use.

d. Total amount used.

A closed system is recommended as it prevents the termiticide from coming into contact with the applicator or other persons. Only use water from designated locations. Fit filling hoses with a backflow preventer meeting local plumbing codes or standards. Prevent overflow during the filling operation. Spill kits must be maintained on pest control vehicles and must be available at the mixing site. Termiticide mixing must be conducted in an area that has been designated by the Government representative and that has adequate spill containment. Inspect the application equipment for applying termiticides prior to each day of use for leaks, clogging, wear, or damage. Immediately perform repairs on the application equipment to prevent or eliminate leaks and clogging.

3.2.2.1 Application Method

3.2.2.1.1 Surface Application

Use surface application for establishing horizontal barriers. Apply surface applicants as a coarse spray and provide uniform distribution over the soil surface. Termiticide must penetrate a minimum of 1 inch into the soil, or as recommended by the manufacturer. If soils are treated to a depth less than specified or approved, repeat work performed to the depth specified at no additional cost to the Government.

3.2.2.1.2 Rodding and Trenching

Use rodding and trenching for establishing vertical soil barriers.

Trenching must be to the depth of the foundation footing. Width of trench must be as recommended by the manufacturer, or as indicated. Rodding or other approved method may be implemented for saturating the base of the trench with termiticide. Backfill the trench immediately after termiticide has reached maximum penetration as recommended by the manufacturer. If maximum penetration is not achieved, as recommended by the manufacturer, repeat work performed to maximum penetration as recommended by the manufacturer at no additional cost to the Government.

Backfill in 6 inch rises or layers. Treat each rise or layer with termiticide.

3.2.3 Sampling

The Contracting Officer may draw samples for analysis, at any time and without prior notice, from stocks at the job site to determine if the amount of active ingredient specified on the label is being applied. When analysis, performed by the Government, indicates samples contain less than the amount of active ingredient specified on the label, repeat work performed with pesticides conforming to this specification at no additional cost to the Government.

SECTION 31 31 16.13 Page 8

3.2.4 Vapor Barriers and Waterproof Membranes

Apply termiticide prior to placement of a vapor barrier or waterproof membrane.

3.2.5 Placement of Concrete

Place concrete covering treated soils as soon as the termiticide has reached maximum penetration into the soil as recommended by the manufacturer.

3.2.6 Clean Up, Disposal, And Protection

Once application has been completed, proceed with clean up and protection of the site without delay.

3.2.6.1 Clean Up

Clean the site of all material associated with the treatment measures, according to label instructions, and as indicated. Remove and dispose of excess and waste material off Government property.

3.2.6.2 Disposal of Termiticide

Dispose of residual termiticides and containers off Government property, and in accordance with label instructions and EPA criteria.

3.3 FIELD QUALITY CONTROL

3.3.1 Verification of Measurement

Once termiticide application has been completed, measure tank contents to determine the remaining volume. The total volume measurement of used contents for the application must equal the application rate established in the application plan. Submit written verification that the volume of termiticide used meets the application rate established in the application plan.

3.3.2 Inspection

3.3.2.1 Technical Representative

Provide a technical representative who is a DOD certified pesticide applicator or Pest Management Quality Assurance Evaluator (QAE)/Performance Assessment Representative (PAR). The technical representative must be present at all meetings concerning treatment measures for subterranean termites and during treatment application.

Contact the Integrated Pest Management Coordinator prior to starting work.

3.4 CLOSEOUT ACTIVITIES

Upon completion of this work, submit the Pest Management Report DD Form 1532, or an equivalent computer product, to the Integrated Pest Management Coordinator. This form identifies the target pest, type of operation, brand name and manufacturer of pesticide, formulation, concentration or rate of application used.

SECTION 31 31 16.13 Page 9

3.5 PROTECTION

3.5.1 Protection of Treated Area

Immediately after the application, protect the area from other use by erecting barricades as required or directed. Place signage inside the entrances to crawl spaces and identify the space as treated with termiticide and not safe for children or animals. Cover treated areas with plastic if slab is not to be poured immediately following termiticide application.

3.5.2 Disturbance of Treated Soils

Re-treat soil and fill material disturbed after treatment before placement of slabs or other covering structures.

-- End of Section --

SECTION 31 31 16.13 Page 10

DW

R e f

WD

W D

Ref

D W

D W

Ref

DW

D

Ref

DW

D W

STORAGE

2-CAR GARAGE

KITCHEN

DINING RM

LIVING - FAMILY RM

BDRM 1

BATH

BDRM 2

108M. CLOS

M. BDRM

M. BATH

WC

PATIO

ENTRY PATIO

A-003

B8

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

EXHAUST FAN

RE: MECH DWGS

S

S

S S

S

TYP. SMOKE-CO2

DETECTOR

TYP. SMOKE-CO2

DETECTOR

CLOSURE AND

20 MIN. RATED

SEPARATION

WALLS

FROM GARAGE AND

HOUSE, SEAL ANY

PENETRATIONS

DOMESTIC WATER

HEATER RE: MECH

DWGS,

COMBUSTION AIR

BACK DOOR EGRESS

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

MECH

TRASH

PATIO

M. BDRM

M. BATH

M. WC

M. CLOSET

BDRM 1

BDRM 2

H A

L L W

A Y

BDRM 3

BATH

PWDR

GARAGE

STOR

DINING RM

LIVING - FAMILY RM

KITCHEN

PANTRY

CLOSET

ENTRY PATIO

LAUNDRY

A-003

B5

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

S

S

S S

S

S

BACK DOOR EGRESS

FRONT DOOR EGRESS

TYP. SMOKE-CO2

DETECTOR

TYP. SMOKE-CO2

DETECTOR

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

CLOSURE AND

20MIN. RATED

SEPARATION WALLS

FROM GARAGE AND

HOUSE, SEAL ANY

PENETRATIONS

DOMESTIC WATER

HEATER RE: MECH

DWGS,

COMBUSTION AIR

EXHAUST FAN

RE: MECH DWGS

MECH

TRASH

DINING RM

KITCHEN

M. BDRM

H A

L L W

A Y

M. BATH

WC

M. CLOSET

BDRM 1

BATH

LAUNDRY

ENTRY

PANTRY

105STOR

GARAGE

CLOSET

CLOSET

CLOSET

PWDR RM

PATIO

ENTRY PATIO

LIVING -FAMILY RM

BDRM 2

A-003

A1

20"WX24"H MIN

44" SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN 44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

DOMESTIC WATER

HEATER

RE: MECH DWGS,

COMBUSTION AIR

FRONT DOOR EGRESS

BACK DOOR EGRESS

CLOSURE AND

20 MIN. RATED

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGSEXHAUST FAN

RE: MECH DWGS

SEPARATION WALLS

FROM GARAGE AND

HOUSE, SEAL ANY

PENETRATIONS

S

S

S

S

S

TYP. SMOKE-CO2

DETECTOR

TYP. SMOKE-CO2

DETECTOR

MECH

TRASH

M. BATH

M. CLOS

H A

L L W

A Y

WC

LAUNDRY

STUDY

M.BDRM

S

S

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

33"X60"

CLEAR AREA

OPERABLE WINDOW

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

TYP. SMOKE-CO2

DETECTOR

PANTRY

FLEX ROOM

PATIO

BACK DOOR EGRESS

MECH

TRASH

M. BDRM

HALL

M. BATH

M. CLOSET

BDRM 3

WC

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

S TYP. SMOKE-CO2

DETECTOR

EXHAUST FAN

RE: MECH DWGS

S

21"x60"

CLEAR AREA

OPERABLE WINDOW

S

JURISDICTION: FT. BUCHANAN, PUERTO RICO

APPLICABLE CODE: INTERNATIONAL RESIDENTIAL CODE (2015)

NFPA 101 (2018)

PUERTO RICO BUILDING CODE

INTERNATIONAL MECHANICAL CODE (2015)

INTERNATIONAL PLUMBING CODE (2015)

INTERNATIONAL ENERGY CONSERVATION CODE

TYPE OF CONSTRUCTION: TYPE II-B

OCCUPANCY: R-3 (IBC)

ONE- AND TWO- FAMILY DWELLING, CHAPTER 24 (NFPA)

FIRE SPRINKLER SYSTEM: PROTECTED, SPRINKLED

REFER TO SHEET A-003 FOR AREA CALCULATIONS

THIS PROJECT SHALL COMPLY WITH ALL OTHER REGULATIONS AND ORDINANCES

ADOPTED BY THE LOCAL GOVERNING AGENCIES.

CODE ANALYSIS

EGRESS REQUIREMENTS: EGRESS REQUIREMENTS AT ALL BEDROOMS:

MIN (1) OPERABLE WINDOW WITH A MIN NET

CLEAR OPERABLE AREA OF 5.7 SQ. FT. THE

MIN NET CLEAR OPERABLE HEIGHT SHALL BE

24" AND WIDTH SHALL BE 20" PER THE IRC.

R VALUES: WALL INSULATION MIN R-14.2

ROOF INSULATION MIN R-30 PLUS TAPER

GARAGE

LIVING - FAMILY RM

DINING RM

KITCHEN

M. BDRM

BDRM 1

BDRM 2

BDRM 3

M. CLOSET

M. BATH

PWDR RM

LAUNDRY

BATH

ENTRY

STOR

PANTRY

105 HALLWAY

WC

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

S

TYP. SMOKE-CO2

DETECTOR

EXHAUST FAN

RE: MECH DWGS

S

S

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

SEPARATION WALLS

FROM GARAGE AND

HOUSE, SEAL ANY

PENETRATIONS

CLOSURE AND

20 MIN RATED

DOMESTIC WATER

HEATER

RE: MECH DWGS,

COMBUSTIAN AIR

EXHAUST FAN

RE: MECH DWGS

MECH

TRASH

BACK DOOR EGRESS

20"WX24"H MIN

44"SILL MAX

CLEAR AREA

OPERABLE WINDOW

FRONT DOOR

EGRESS

S

S

S

EXHAUST FAN

RE: MECH DWGS TYP. SMOKE-CO2

DETECTOR

EXHAUST FAN

RE: MECH DWGS

EXHAUST FAN

RE: MECH DWGS

PATIO

ENTRY

PATIO

D

2 3

C

A

B

SHEET ID

S O

L

IC

IT

A

T

IO

N N

O

D R

A W

N B

Y

C K

D B

Y

D E

S

IG

N B

Y

IS

S

U E

D A

T E

S B

M T

B Y

C O

N T

R A

C T

N O

S

IZ

E

"X

P R

O J E

C T

N U

M B

E R

F

IL

E N

A M

E

US Army Corps of Engineers ®

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S J A

C K

S O

N V

IL

L

E D

IS

T

R

IC

T

S

A N

M A

R C

O B

L V

D

J A

C K

S O

N V

IL

L

E F

L O

R

ID

A

6 7 8 9 10

E

F

G

A .R

IV

A

R D

B .P

O R

TE

R

E . S

A N

TO

S

A . R

IV

A

R D

A -0

.D

W G

A-003

A R

C H

IT

E

C T

U R

A L C

O D

E A

N A

L Y

S

IS

L

IF

E S

A F

E T

Y P

L A

N S

RTA SUBMITTAL

A U

G U

S T

W

2E P

R

F O

R T

B U

C H

A N

A N

G

U A

Y N

A B

O P

U E

R T

O R

IC

O

F O

R T

B U

C H

A N

A N

F A

M

IL

Y H

O U

S

IN

G R

E P

L A

C E

M E

N T

D8

LIFE SAFETY PLAN - MODEL A.A

D5

LIFE SAFETY PLAN - MODEL B.A

D1

LIFE SAFETY PLAN - MODEL C.A

B8

LIFE SAFETY PLAN - MODEL A.B

B5

LIFE SAFETY PLAN - MODEL B.B

A1

LIFE SAFETY PLAN - MODEL C.B

A3

LIFE SAFETY PLAN - MODEL C.C

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D P

E R

A M

E N

D M

E N

T

O

C T arivard Stamp

DW

R e f

WD

W D

Ref

D W

D W

Ref

DW

D

STORAGE

2-CAR GARAGE

KITCHEN

DINING RM

LIVING - FAMILY RM

BDRM 1

BATH

BDRM 2

108M. CLOS

M. BDRM

M. BATH

WC

PATIO

ENTRY PATIO

H A

L L W

A Y

A-004

A7

188 SF

122 SF

114 SF

GREAT ROOM

GREAT ROOM

602SF

PATIO

M. BDRM

M. BATH

M. WC

M. CLOSET

BDRM 1

BDRM 2

H A

L L W

A Y

BDRM 3

BATH

PWDR

GARAGE

STOR

DINING RM

LIVING - FAMILY RM

KITCHEN

PANTRY

CLOSET

ENTRY PATIO

LAUNDRY

A-004

A5

120 SF

118 SF

150 SF

224 SF

GREAT ROOM

GREAT ROOM

780SF

DINING RM

KITCHEN

M. BDRM

H A

L L W

A Y

M. BATH

WC

M. CLOSET

BDRM 1

BATH

LAUNDRY

ENTRY

PANTRY

105STOR

GARAGE

CLOSET

CLOSET

CLOSET

PWDR RM

PATIO

ENTRY PATIO

LIVING -FAMILY RM

BDRM 2

A-004

A1

126 SF

131 SF

GREAT ROOM

GREAT ROOM

663SF

M. BATH

BDRM 1

BDRM 2

BATH

M. CLOS

WC

LAUNDRY

STUDY

M.BDRM

118213 SFPANTRY

FLEX ROOM

PATIO

M. BDRM

HALL

M. BATH

M. CLOSET

BDRM 3

WC

213 SF

108 SF

126 SF

M. BDRM

DINING RM

KITCHEN

LIVING - FAMILY RM

M. CLOSET

M. BATH

BDRM 3

BDRM 2

H A

L L W

A Y

PWDR RM

LAUNDRY

BATH

BDRM 1

GARAGE

STOR

PANTRY

ENTRY

205 SF

103 SF

136 SF

GREAT ROOM

GREAT ROOM

557 SF

103 SF

D

2 3

C

A

B

SHEET ID

S O

L

IC

IT

A

T

IO

N N

O

D R

A W

N B

Y

C K

D B

Y

D E

S

IG

N B

Y

IS

S

U E

D A

T E

S B

M T

B Y

C O

N T

R A

C T

N O

S

IZ

E

"X

P R

O J E

C T

N U

M B

E R

F

IL

E N

A M

E

US Army Corps of Engineers ®

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S J A

C K

S O

N V

IL

L

E D

IS

T

R

IC

T

S

A N

M A

R C

O B

L V

D

J A

C K

S O

N V

IL

L

E F

L O

R

ID

A

6 7 8 9 10

E

F

G

A . R

IV

A

R D

B . P

O R

T E

R

E . S

A N

T O

S

A . R

IV

A

R D

A -0

.D

W G

A-004

A R

C H

IT

E

C T

U R

A L M

O D

E L A

R E

A P

L A

N S

RTA SUBMITTAL

A U

G U

S T

W

2E P

R

F O

R T

B U

C H

A N

A N

G

U A

Y N

A B

O P

U E

R T

O R

IC

O

F O

R T

B U

C H

A N

A N

F A

M

IL

Y H

O U

S

IN

G R

E P

L A

C E

M E

N T

D7

AREA PLAN - MODEL A.A

D5

AREA PLAN - MODEL B.A

D1

AREA PLAN - MODEL C.A

A7

AREA PLAN - MODEL A.B

A5

AREA PLAN - MODEL B.B

A1

AREA PLAN - MODEL C.B

MODEL A.A 2291.50 SQFT

MODEL A.B 2829.83 SQFT

MODEL A.B ADD OF 229.50 SQFT PER ANSI Z765

ADD OF 238.33 SQFT GROSS SQUARE FOOTAGE

MODEL B.A 3018 SQFT

MODEL B.B 3188.28 SQFT

MODEL B.B ADD OF 217.39 SQFT PER ANSI Z765

ADD OF 219.78 SQFT GROSS SQUARE FOOTAGE

MODEL C.A 2620.01 SQFT

MODEL C.B 2786.68 SQFT

MODEL C.C 1950 SQFT

MODEL C.B ADD OF 171.50 SQFT PER ANSI Z765

ADD OF 178.22 SQFT GROSS

SQUARE FOOTAGE

PER ANSI Z765PER ANSI Z765

PER ANSI Z765

GROSS SQUARE FOOTAGE

HABITABLE SPACE

MODEL C.A = 2033.75 SQFT

MODEL C.B = 2200.42 SQFT

GARAGE - STORAGE 586.26 SQFT

MODEL C.C = 1989 SQFT

GARAGE - STORAGE 629 SQFT

GROSS SQUARE FOOTAGE

HABITABLE SPACE

MODEL B.A = 2359.11 SQFT

MODEL B.B = 2529.39 SQFT

GARAGE - STORAGE 658.89 SQFT

GROSS SQUARE FOOTAGE

HABITABLE SPACE

MODEL A.A = 1661.33 SQFT

MODEL A.B = 1899.66 SQFT

GARAGE - STORAGE 630.17SQFT

SOW REQUIRED VALUES:

C.A 2,020 SQFT

C.B 2,150 SQFT

C.C 1,950 SGFT

SOW REQUIRED VALUES:

B.A. 2,310 SQFT

B.B. 2,520 SQFT

SOW REQUIRED VALUES:

A.A. 1,630 SQFT

A.B. 1,860 SQFT

A3

AREA PLAN - MODEL C.C

MODEL C.C 1,950 SQFT PER ANSI Z765

1,989 SQFT GROSS SQUARE FOOTAGE

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D P

E R

A M

E N

D M

E N

T

O

C T

W D

Ref

D W

PATIO

M. BDRM

M. BATH

M. WC

M. CLOSET

BDRM 1

BDRM 2

H A

L L W

A Y

BDRM 3

BATH

PWDR

GARAGE

STOR

DINING RM

LIVING - FAMILY RM

KITCHEN

PANTRY

CLOSET

ENTRY PATIO

LAUNDRY

B1 B2 B3 B4 B5 B6 B7

BF

BG

BE

BD

BC

BB

BA

C1

A-221B

E1

A-302B

E1

A-302B

B1

A-302B

B1

A-302B

4 5

S L O

P E

S L O

P E

/8

S L O

P E

/8

101C

116B

113113B

111B 111

115B

115A

101B

W1

W1

W1

W1

W4

W4 W4108

109 116

W5

W5 W5

101A

W4

5" MAX

A-401B

E1

A-401B

B1

A5

A-331B

B9

A-312

B9

A-313

A-504

A1

A-504

A1

A-504

A1

W7 W7

A-402B

C4

A2

A-331B

SLOPE

1/8" FT.

MECH/TRASH

B4

A-313

B2

A-312

W7

B5

A-314

B8

A-314

EQ EQ EQ

1 1

8M1

8M1

8M1

W1

A-402B

A7

8M1

8M1

A-102B

E7 B .B

B

.AB

.B

B .A

A-505

B7

SHEET KEYNOTESNOT ALL MAY APPLY

1. MECHANICAL VENTILATOR UNIT; RE: MECHANICAL

DRAWINGS

2. ELECTRICAL PANEL, RE: ELECTRICAL DWGS.

3. WASHER SPACE: PROVIDE RECESSED WATER AND

DRAIN CONNECTIONS. REF. PLUMB DRAWINGS.

4. DRYER SPACE: PROVIDE DRYER VENT. REF MECH

DRAWINGS.

5. WATER HEATER ON 6" HIGH PLATFORM, SEISMIC STRAPS

REQUIRED ON WATER HEATERS WITHIN UPPER ONE-

THIRD (1/3) AND LOWER ONE-THIRD (1/3) OF ITS

VERTICAL DIMENSIONS.

6. PROVIDE HURRICANE GARAGE DOOR BRACING

(REMOVABLE STORABLE SYSTEM).

7. GARAGE DOORS SHALL BE LISTED AND LABELED IN

ACCORDANCE TO UL 325. GARAGE DOORS SHALL BE

TESTED IN ACCORDANCE WITH EITHER ASTM E330 OR

ANSI/DASMA 108 AND SHALL MEET THE ACCEPTANCE

CRITERIA OF ANSI/DASMA 108.

8. TIGHT FITTING DOOR, WITH SELF-CLOSING HARDWARE.

9. 8" CMU WALL BELOW.

10. AC CONDENSING UNIT ON 6" CURB. REF MECH

DRAWINGS.

11. OPEN SCREEN WALL BLOCK - 8X8X8 CMU ON SIDE.

REFER TO DETAIL A1/A-504

12. PREFINISHED SHEET METAL DOWN SPOUT TO

SPLASH BLOCK WITH 6' EXTENSION AT GROUND LEVEL.

13. 4" CAST-IN-PLACE CONCRETE SIDEWALK

RE: CIVIL DWGS.

14. 16" CLOSET SHELF AND ROD ON BRACKETS AT 2'-0"OC.

15. (5) SHELVES, 12" DEEP WITH BULLNOSE EDGE WITH

HEAVY DUTY STANDARDS AND BRACKETS AT 2'-0" OC.

16. OVERHEAD GARAGE DOOR OPENER, MOTION SENSOR

LIGHT, (2) REMOTE OPERATORS, BATTERY BACK-UP.

17.RAIN BARREL, RAIN WATER CATCHMENT CONTAINER

WITH 4" CONCRETE PAD.

PATIO FLEX ROOM

B3 B4 B5 B6 B7

BB

BA

C1

A-222B W6 W6

W1

MECH/TRASH

101C

13 13

B5

A-314

B .B

B .A

B .B

B .A

1. ALL INTERIOR WALLS TO BE 6M, UNLESS NOTED

OTHERWISE.

GENERAL SHEET NOTES

MODEL C.B

MODEL C.A

D

2 3

C

A

B

SHEET ID

S O

L

IC

IT

A

T

IO

N N

O

D R

A W

N B

Y

C K

D B

Y

D E

S

IG

N B

Y

IS

S

U E

D A

T E

S B

M T

B Y

C O

N T

R A

C T

N O

S

IZ

E

"X

P R

O J E

C T

N U

M B

E R

F

IL

E N

A M

E

US Army Corps of Engineers ®

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S J A

C K

S O

N V

IL

L

E D

IS

T

R

IC

T

S

A N

M A

R C

O B

L V

D

J A

C K

S O

N V

IL

L

E F

L O

R

ID

A

6 7 8 9 10

E

F

G

KEY PLANS

A . R

IV

A

R D

B . P

O R

TE

R

E . S

A N

TO

S

A . R

IV

A

R D

A -1

B

.D W

G

A-102B

A R

C H

IT

E

C T

U R

A L F

L O

O R

P L A

N N

O T

E S

M

O D

E L

B .A

B

.B

RTA SUBMITTAL

A U

G U

S T

W

2E P

R

F O

R T

B U

C H

A N

A N

G

U A

Y N

A B

O P

U E

R T

O R

IC

O

F O

R T

B U

C H

A N

A N

F A

M

IL

Y H

O U

S

IN

G R

E P

L A

C E

M E

N T

1/4" = 1'-0"A1

FLOOR PLAN NOTES - MODEL B.A

0 1' 2' 4' 8'

1/4" = 1'-0"E7

FLEX ROOM - MODEL B.B

0 1' 2' 4' 8'

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

R

E V

IS

E

D P

E R

A M

E N

D M

E N

T

O

C T

10.26.2020

ROOF DECK

110' - 0"

KITCHEN

DINING RM

LIVING - FAMILY RM

M. BDRM

AF AE AC AB AAAD

B1

A-301A

3 3

FIRST FLOOR

100' - 0"

LAUNDRY

899 9

ROOF DECK

110' - 0"

A3A4A5 A1A2

E1

A-301A

LIVING - FAMILY RM

MECH/TRASH

1. FLUID APPLIED AIR/WATER BARRIER MEMBRANE O/ R-30

(MIN) RIGID INSULATION O/ 1/2" EXTERIOR GLASS MAT

COVERBOARD O/ FLUID APPLIED ROOFING. EXTEND

ROOFING SYSTEM UP PARAPET WALL.

2. ELASTOMERIC WATERPROOF MEMBRANE BELOW SLAB.

3. DIRECT APPLIED FINISH SYSTEM AT ALL VERTICAL

WALLS, AND UNDERSIDE OF OVERHANGS.

4. SLOPE SLAB TO DRAIN AWAY FROM BUILDING.

5. MATT FOUNDATION, REF STRUCTURAL.

6. BREEZE BLOCK - 8X8X16 CMU ROTATED AT 90 DEGREES.

7. THROUGH WALL ROOF SCUPPER AND DOWNSPOUT.

8. SOLAR PHOTO VOLTAIC PANELS RE: ELECTRICAL.

9. MECHANICAL UNITS AND PIPING RE: MECHANICAL.

10. MECHANICAL ROOF EXHAUST CAP RE: MECHANICAL.

11. CABINETS, REFER TO INTERIOR ELEVATIONS FOR

ADDITIONAL INFORMATION.

SHEET KEYNOTES

D

2 3

C

A

B

SHEET ID

S O

L

IC

IT

A

T

IO

N N

O

D R

A W

N B

Y

C K

D B

Y

D E

S

IG

N B

Y

IS

S

U E

D A

T E

S B

M T

B Y

C O

N T

R A

C T

N O

S

IZ

E

"X

P R

O J E

C T

N U

M B

E R

F

IL

E N

A M

E

US Army Corps of Engineers ®

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .