About this file

This solicitation package includes plans for water and sewer repairs at three campgrounds in Polk County, Iowa. The base bid covers work at Bob Shetler Campground and includes directional drilling, trenching, valve and hydrant installation, lift station construction, piping, manholes, concrete, asphalt and site restoration. Option A involves work at Cherry Glen Campground such as sewer lining, piping and manhole rehabilitation, lagoon work and trail repairs. Option B covers directional drilling, valves, hydrants, vaults, piping, lift station and restoration at Prairie Flower Campground. The solicitation was issued by the US Army Corps of Engineers Rock Island District for its MATOC/IDIQ contract. The plans provide design details for the work specified in the solicitation.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

L

U P

U P

U P

U P

U P

U P

U P

U P

U P

U P

U

PUPUP

C O

U

TIL

U

C O

U P

U

U

U

U

R O

C K

I S

L A

N D

IL

L

IN

O

IS

R O

C K

I S

L A

N D

D

IS

T R

IC

T

A N

S I

D

S O

L

IC

IT

A

T

IO

N

W A

T E

R A

N D

S E

W E

R R

E P

A

IR

S

P R

A

IR

IE

F

L O

W E

R C

H E

R R

Y G

L E

N A

N D

B O

B S

H E

T L

E R

S A

Y L

O R

V

IL

L E

L A

K E

D E

S M

O

IN

E S

R

IV

E R

B A

S

IN

/0

/1

A H

E D

D L

E S

T E

N

O P

T

IO

N A

B O

B S

H E

T L

E R

S E

W E

R

P L

A N

A N

D P

R O

F

IL

E

C-122

L

H A

R P

E R

T

G A

M B

O N

A U

G

A U

G

M

D T

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

D T

A M

D T

R

E V

IS

E

D I

N A

C C

O R

D A

N C

E W

IT

H

A M

D T

B

S A

Y L

O R

R

F E

L L

M

N

W

E K

B

A1

SCALE: 100' = 1' - 0"

PROFILE - BOB SHETLER SEWER - OPTION A

STAGING AREA

SEE NOTE 4

BORE PIT

STA 11+38.41

SEE SHEET M-501 FOR DETAILS

INSTALL DUPLEX LIFT STATION

E619360.741

N1588940.858

STA 1+54.45

SEE NOTE 1

REHAB EXISTING LIFT STATION

STA 0+00

H1

SCALE: 100' = 1' - 0"

PLAN - BOB SHETLER SEWER - OPTION A

SANITARY SEWER UNDER RIVER

INSTALL 1.5" HDPE PRESSURE

CONNECT 1.5" HDPE PRESSURE SANITARY SEWER

REPLACE SANITARY SEWER MANHOLE

STA 12+73.02

EXISTING GROUND

INSTALL DUPLEX LIFT STATION

REHAB EXISTING LIFT STATION

REPLACE SANITARY SEWER MANHOLE

SEE NOTE 2

ABANDON EXISTING 4" PVC SANITARY SEWER

INV EL 823.0

INV EL 821.0

INV EL 819.0

INV EL 822.0

E620045.009

N1588933.856

START FLOWABLE FILL

INSTALL 6" PVC SANITARY SEWER

DESIGN GRADE

INSTALL 6" PVC SANITARY SEWER

INSTALL 1.5" HDPE PRESSURE SANITARY SEWER

SEE NOTE 4

BORE PIT

STA 11+38.41

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

IT

T

E D

B Y

C H

E C

K E

D B

Y

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

C O

N T

R A

C T

/T .O

N

O

S O

L

IC

IT

A

T

IO

N N

O

IS

S

U E

D A

T E

S I Z

E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

SHEET ID

®of Engineers

US Army Corps

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

P R

O J E

C T

C O

D E

M A

T O

C /I

D

IQ

C O

N T

R A

C T

N O

0+00

1+00

.0

S

L

0+00 1+00 2+00 3+00 4+00 5+00 6+00 7+00 8+00 9+00 10+00 11+00 12+00 13+00

770 770

780 780

790 790

800 800

810 810

820 820

830 830

840 840

850 850

N

BOB SHETLER CAMPGOUND

200'0 100'

D E

S M

O

IN

E S R

IV

E R

F L

O W

100' 200'0

WATER AVE

APPROVAL PRIOR TO START OF WORK.

DIRECTIONAL DRILLING WORK PLAN TO BE SUBMITTED FOR REVIEW AND

DETERMINED BY THE CONTRACTOR AND IDENTIFIED IN THE HORIZONTAL

BORE PIT LOCATIONS ARE APPROXIMATE. FINAL LOCATIONS TO BE 4.

INSTALLATION FOR REVIEW AND APPROVAL BY THE CONTRACTING OFFICER.

AT 5 FOOT MINIMUM DEPTH. FIELD STAKE LIMITS OF OPEN TRENCH

SEWER LINES TO BE INSTALLED USING HORIZONTAL DIRECTIONAL DRILLING

WITHIN 50 FEET OF STABILITY BERM TOE USING OPEN TRENCH. ALL OTHER

INSTALL ALL SEWER LINES IN BOB SHETLER CAMPGROUND AND ANY LINES 3.

CONTRACTING OFFICER PRIOR TO GROUTING OPERATIONS.

END. STAKE GROUTING LIMITS FOR REVIEW AND APPROVAL BY THE

END TO A MINIMUM OF 50 FEET FROM THE TOE OF THE DAM AT THE WEST

SEWER WITH FLOWABLE FILL FROM THE EXISTING MANHOLE AT THE EAST

ONCE NEW LIFT STATION IS IN SERVICE, FILL EXISTING 4" PVC SANITARY 2.

VAULT WITH FLOWABLE FILL TO INVERT OF NEW SANITARY SEWER.

CONNECT NEW 6" PVC SANITARY SEWER TO EXISTING LIFT STATION AND FILL

MECHANICAL EQUIPMENT FROM INSIDE THE VAULT AND DISPOSE OFFSITE.

DISCONNECT EXISTING LIFT STATION. REMOVE ALL ELECTRICAL AND 1.

GENERAL SHEET NOTES

NW

78TH AVE

File details come from the government source that posted it. Updated .