A22_-_Plans_Volume_3_-_Upper_Guidewall_Repairs(c).pdf

PDF 24 MB Posted

Attached to
Illinois River Basin, Dresden Island Lock, Grundy County, IL Upper Bulkhead Recesses
Solicitation number
W912EK19R0016
Issued by

About this file

Plans - Volume 3: Upper Guidewall Repair (File 3 of 4)

View the file

Other files

File Type Posted
AMEND_0006_DRAWING.pdf PDF
W912EK19R0016_AMENDMENT_0006.pdf PDF
20180807_DResden_W912EK19R0016_Pre-Bid_Sign-In_Sheet.pdf PDF
W912EK19R0016_AMEND_0005.pdf PDF
AMEND_0005_DRAWINGS.pdf PDF
W912EK19R0016_Amendment_0004.pdf PDF
W912EK19R0016_AMEND_0003_DRAWINGS.pdf PDF
W912EK19R0016_Amendment_0003.pdf PDF
W912EK19R0016_Amendment_0002.pdf PDF
W912EK19R0016_Amendment_0002_BULKHEAD_Plan_Set.pdf PDF
W912EK19R0016_Amendment_0002_BUMPER_SYSTEM_Plan_Set.pdf PDF
W912EK19R0016_Amendment_0002_Drawings.pdf PDF
A22_-_Site_Visit_Attendees.pdf PDF
A22_-_W912EK19R0016_Amendment_0001.pdf PDF
A22_-_Reference_Drawings(a).pdf PDF
A22_-_Reference_Drawings(f).pdf PDF
A22_-_Plans_Volume_2_-_Machinery_Pit_Repairs(e).pdf PDF
A22_-_Plans_Volume_2_-_Machinery_Pit_Repairs(d).pdf PDF
A22_-_Plans_Volume_3_-_Upper_Guidewall_Repairs(b).pdf PDF
A22_-_Plans_Volume_2_-_Machinery_Pit_Repairs(a).pdf PDF
A22_-_Reference_Drawings(d).pdf PDF
A22_-_Reference_Drawings(k-1).pdf PDF
A22_-_Reference_Drawings(h).pdf PDF
A22_-_Reference_Drawings(k-2).pdf PDF
A22_-_Plans_General(a).pdf PDF
A22_-_Reference_Drawings(j).pdf PDF
A22_-_Reference_Drawings(g).pdf PDF
A22_-_Reference_Drawings(i-1).pdf PDF
A22_-_Plans_General(d).pdf PDF
A22_-_Reference_Drawings(c).pdf PDF
A22_-_Plans_General(c).pdf PDF
A22_-_Reference_Drawings(l).pdf PDF
A22_-_Plans_Volume_2_-_Machinery_Pit_Repairs(b).pdf PDF
A22_-_Plans_Volume_3_-_Upper_Guidewall_Repairs(d).pdf PDF
A22_-_Plans_Volume_3_-_Upper_Guidewall_Repairs(a).pdf PDF
A22_-_Plans_Volume_1_-_Bulkhead_Recess(b).pdf PDF
A22_-_Reference_Drawings(e).pdf PDF
A22_-_Plans_Volume_2_-_Machinery_Pit_Repairs(c).pdf PDF
A22_-_Plans_Volume_1_-_Bulkhead_Recess(a).pdf PDF
A22_-_Reference_Drawings(b).pdf PDF
A22_-_Plans_General(b).pdf PDF
A22_-_W912EK19R0016.pdf PDF
A22_-_Reference_Drawings(i-2).pdf PDF
A14_-_Draft_Plans_Part_1.pdf PDF
A14_-_Draft_Plans_Part_4.pdf PDF
A14_-_Draft_Plans_Part_2.pdf PDF
A14_-_Draft_Plans_Part_3.pdf PDF
A14_-_Draft_Plans_Part_5.pdf PDF
A14_-_Draft_Specifications.pdf PDF
Show all 49

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

E

SHEET ID

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

W E

K

R

A N

S I

D

E ic s p d f2 \2

\5

\B

IW

L D

V O

L -I

II

S -1 x x x .d g n

:3

:0

A

M

C O

E -M

V R

P W

P

R O

C

/3

/2

N .T .S

S-124

B

IW

L D

R O

C K I S

L A

N D

IL

L

IN

O

IS

R O

C K I S

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

IL

L

IN

O

IS

R

IV

E R B

A S

IN

G R

U N

D Y C

O U

N T

Y

IL

D R

E S

D E

N I S

L A

N D L

O C

K

U P

P E

R B

U L

K H

E A

D R

E C

E S

S E

S

U P

P E

R A

P P

R O

A C

H W

A L L B

U L L N

O S

E

P L

A N

B

IW

L D

V O

L -I

II

S -1 x x x .d g n

0 2' 4' 8'SCALE : 1/4"=1'-0"

S A

W C

U T J

O

IN

T S A

N D D

R A

IN

A G

E

FLOW

GENERAL SHEET NOTES

CONCRETE SLAB THICKNESS.

THE DEPTH OF THE3

1SAWCUT JOINTS SHALL BE 4.

BULLNOSE.

" = 1'-0" TOWARDS THE EDGE OF THE8

1CHANGES TO

RESURFACING, WHERE THE DRAINAGE SLOPE

ABUTTING EDGES OF PERIMETER CONCRETE

EDGES OF CENTER SLABS SHALL BE FLUSH WITH3.

" = 1'-0".4

1AND SLOPED AWAY AT

CENTER SLABS SHALL BE DOMED AT THEIR CENTERS2.

OR CENTER OF CONCRETE EDGE.

CENTER OF ARC, CORNER OF FORMED CONCRETE,

IF NO DIMENSION IS SHOWN, THE JOINT IS AT THE1.

A1

PLAN - SAWCUT JOINTS AND DRAINAGE

DOWNWARD SLOPE DIRECTION

8'-2

5'-2

6'-3" 5'-0" 6'-3" 6'-3" 5'-0" 6'-3"

45° (TYP.)

° (T

YP.)

3'-3 "16

1'- 9

10' -11

"8

'-8

"4

8'-6

12.6

B J

O N

E S

C

D E

L O

N G

/0

/2

A

R O

D

VOLUME III

SOLICITATION

B J

O N

E S

"16 118'-1

A

S I

D

E ic s p d f2 \2

\5

\B

IW

L D

V O

L -I

II

S -3 x x x .d g n

:3

:1

A

M

C O

E -M

V R

P W

P

R O

C

/3

/2

.S

S-301

IW

L D

R O

C K I S

L A

N D

IL

L

IN

O

IS

R O

C K I S

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

IL

L

IN

O

IS

R

IV

E R B

A S

IN

G R

U N

D Y C

O U

N T

Y

IL

D R

E S

D E

N I S

L A

N D L

O C

K

U P

P E

R B

U L

K H

E A

D R

E C

E S

S E

S

B

IW

L D

V O

L -I

II

S -3 x x x .d g n

A1

SECTION

EXISTING APPROACH WALL

GENERAL SHEET NOTES

U P

P E

R A

P P

R O

A C

H W

A L L

S E

C T

IO

N

C O

N C

R E

T E R

E P

L A

C E

M E

N T

REPLACEMENT

" EXPANSION JOINT2

BY OTHERS

SUPPLIED/INSTALLED

HANDRAILS

BOND BREAKER

TAR PAPER

2'1'0SCALE : 1"=1'-0"

EXISTING KEVEL RAIL

EXISTING COLD JOINT

4'-5"

M

IN

2" DEEP SAWCUT

(MID-DEPTH)

6 X 6 W6/W6 WELDED WIRE REINFORCEMENT

SLOPE 1/8" : 1'-0"

fy = 60,000 PSI.

5. YIELD STRENGTH OF WELDED WIRE REINFORCING,

4. CONCRETE COMPRESSIVE STRENGTH f'c = 4,500 PSI.

TRAFFIC.

BROOM FINISH PERPENDICULAR TO THE DIRECTION OF

3. NEW CONCRETE ON APPROACH WALL SHALL RECEIVE A

CONTROL JOINTS WILL BE REQUIRED PER THE COR.

REMOVALS ARE DETERMINED IN FIELD, ADDITIONAL CRACK

IRREGULARITIES MORE THAN 3/8". IF LOCAL DEEPER

OVERLAY SHALL BE SMOOTH WITH NO SURFACE

2. EXISTING CONCRETE SURFACES TO RECEIVE A CONCRETE

ASPHALYIC-SATURATED ORGANIC FELT UNDERLAYMENT.

EXISTING CONCRETE WITH ASTM D4869, TYPE I OR TYPE II

1. UNDERLAY ALL NEW CONCRETE TO BE REPLACED OVER

VOLUME III

B J

O N

E S

C

D E

L O

N G

/0

/2

A

R O

D

SOLICITATION

B J

O N

E S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

E

SHEET ID

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

W E

K

R

S I

D

E ic s p d f2 \2

\5

\B

IW

L D

V O

L -I

II

S -3 x x x .d g n

:3

:4

A

M

C O

E -M

V R

P W

P

R O

C

/3

/2

.S

S-321

IW

L D

R O

C K I S

L A

N D

IL

L

IN

O

IS

R O

C K I S

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

IL

L

IN

O

IS

R

IV

E R B

A S

IN

G R

U N

D Y C

O U

N T

Y

IL

D R

E S

D E

N I S

L A

N D L

O C

K

U P

P E

R B

U L

K H

E A

D R

E C

E S

S E

S

U P

P E

R A

P P

R O

A C

H W

A L L B

U L L N

O S

E

B

IW

L D

V O

L -I

II

S -3 x x x .d g n

R E

IN

F O

R C

E M

E N

T

0 1' 2' 4'SCALE : 1/2"=1'-0"

S E

C T

IO

N

"2

15'-4" EXPANSION JOINT4

D O

W E

L S

T O

P O

F

" 8 "" : 1'-0"8

1SLOPE

STRAP ANCHORS TO REMAIN

TAR PAPER BOND BREAKER

REPLACEMENT

SECTION A-A

" : 1'-0"4

1SLOPE " : 1'-0"4

1SLOPE

C L

1'-0" (TYP.)

1'-0" (TYP.)

" : 1'-0"8

1SLOPE

" EXPANSION JT MATERIAL4

8" DIA. SOCKET-CONNECT MALE PLUG

C O

M P

A C

T E

D G

R A

V E

L

(T

O P B

A R

S

COVER DOWELS W/ 6 MIL POLY SHEETING

" : 1'-0"8

1SLOPE

DRILL AND INSERT #6 DOWELS

GENERAL SHEET NOTES

A1

SECTION - BULLNOSE CENTER CONCRETE

0 6" 1' 2'SCALE : 1"=1'-0"

(NO CONCRETE)

8" SCH. 40 PVC PIPE OBSERVATION PORTS

1'-0"

C T

O P B

A R

S L

6 MIL. POLY SHEETING

REPLACEMENT

A7

SECTION - BULLNOSE CELL CAP CONCRETE

EDGE.

CONCRETE SHALL BE SLOPED AT 1/8":1'-0" TO THE CONCRETE

SLOPED AT 1/4":1'-0" TO THE CELL CAP CONCRETE. CELL CAP

5. CENTER CONCRETE SHALL BE DOMED IN THE CENTER AND

REINFORCING GRID AS REFERENCE.

CLOSE TO THAT SHOWN ON DRAWING S-123, USING

4. 8" PVC PIPE OBSERVATION PORTS SHALL BE LOCATED AS

3/4" EXPANSION MATERIAL.

3. ENTIRE PERIMETER OF CENTER CONCRETE SHALL HAVE

BONDING TO CONCRETE.

OVERLAYED WITH 6 MIL POLY SHEETING TO PREVENT

COMPACTED GRAVEL. THE EXPOSED PORTIONS SHALL BE

2. #6 DOWELS SHALL BE LOCATED AT THE TOP OF THE

OF ADHESIVE REQUIRED.

1. #6 DOWELS NEED TO FIT TIGHT IN DRILLED HOLES. NO FORM

LENGTH RADIUS

REINFORCEMENT BAR SCHEDULE

QTY

9'-9"

12'-9"

13'-9"

10'-9"

11'-9"

9'-9"

13'-9"

13'-9"

9'-9"

11'-9"

12'-9"

9'-9"

10'-9"

12'-9"

13'-9"

10'-9"

11'-9"

DESIGNATION

BAR

42'-8"

N/A

VARIES N/A

14'-6"

VARIES

VARIES

52'-3"

46'-4"

BAR W

BAR V

BAR U

BAR T

BAR S

BAR R

BAR Q

BAR P

BAR O

BAR N

BAR M

BAR L

BAR K

BAR J

BAR I

BAR H

BAR G

BAR F

BAR E

BAR D

BAR C

#4 BAR B

#4 BAR A

#4

N/A

N/A

N/A

17'-6"

26'-5"

25'-4"

27'-1"

17'-6"

17'-8"

20'-1"

19'-4"

22'-4"

20'-7"

10'-5"

N/A

N/A

7'-2" EA

20'-11"

32'-11"

19'-10" EA

54'-10"

58'-10"

VOLUME III

B J

O N

E S

C

D E

L O

N G

/0

/2

A

R O

D

SOLICITATION

B J

O N

E S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

E

SHEET ID

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

W E

K

R

SB502-A1

N

S I

D

E ic s p d f2 \2

\5

\B

IW

L D

V O

L -I

II

S -5 x x x .d g n

:3

:2

A

M

C O

E -M

V R

P W

P

R O

C

/3

/2

.S

S-501

IW

L D

R O

C K I S

L A

N D

IL

L

IN

O

IS

R O

C K I S

L A

N D D

IS

T R

IC

T

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

IL

L

IN

O

IS

R

IV

E R B

A S

IN

G R

U N

D Y C

O U

N T

Y

IL

D R

E S

D E

N I S

L A

N D L

O C

K

U P

P E

R B

U L

K H

E A

D R

E C

E S

S E

S

B

IW

L D

V O

L -I

II

S -5 x x x .d g n

8'-0"

4"

4"7 SP @ 2'-6" = 17'-2"2'-2"

TOP OF UPPER APPROACH WALL

PIER 1

C

PIER 2

C

PIER 3

C

4"

6"

L L L

S

P

SCALE : 3/8"=1'-0" 0 2' 4' 6'

E N

D O

F W

A L L S

E A

T

E N

D O

F L

A N

D W

A L L

"4

3PL

(TYP)

Ø1" x 15" ANCHOR

BULL

NOSE

LANDW

ALL

EXISTING APPROACH WALL

PIER NO.1

PIER NO.2

PIER NO.3

WALL MONOLITH 1

A1

SB502-A1

2'-2"

3 SP @ 2'-6" = 7'-6"1'-2"

D E

T A

IL

U P

P E

R A

P P

R O

A C

H W

A L L

E X

T E

R N

A L R

E

IN

F O

R C

IN

G P

L A

T E

GENERAL SHEET NOTES

REMAIN UPON APPROVAL BY COR.

ON SHOP DRAWINGS. LIFTING LUGS MAY BE ALLOWED TO

9. LIFTING LUG TYPE AND LOCATION SHALL BE CLEARLY SHOWN

WALL, AND SUBMITTED FOR GOVERNMENT APPROVAL.

GROUND SMOOTH ON THE INTERFACE WITH THE CONCRETE

SPICE(S) WILL BE CJP WELDS IN COMPLIANCE WITH AWS D1.1,

8. WELD SPLICE(S) WILL BE PERMITTED IN REINFORCING PLATE.

REINFORCING PLATE TO WALL. (SEE SHEET SD901)

7. REMOVE ALL APPURTANCES REQUIRED TO MOUNT

6. COAT ALL PLATE SURFACES WITH 5 E-Z PAINT SYSTEM.

PRODUCTS, INC. MAY BE ONE SUCH SUPPLIER.

TYPE 1 OR TYPE IV, GRADE 3 (NON-SAGGING). FIVE STAR

WITH EPOXY-RESIN BASE BOUNDING SYSTEM PER ASTM C881,

BETWEEN THE REINFORCING PLATE AND CONCRETE WALL

5. CLEAN CONCRETE PLATE CONTACT AREA AND FILL ALL VOIDS

THE ANCHOR. ONE SUCH PRODUCT IS HILTI HIT-HY 100.

BE CAPABLE OF DEVELOPING THE FULL YIELD STRENGTH OF

HOLE SHALL BE FILLED WITH ADHESIVE. THE ADHESIVE SHALL

FAST-CURE MORTAR. THE ENTIRE VOID BETWEEN ROD AND

ADHESIVE SHALL BE A HYBRID URETHANE METHACRYLATE

(AS SHOWN) PER ADHESIVE MANUFACTURER'S INSTRUCTIONS.

4. ALL ANCHORS SHALL BE INSTALLED IN DRILLED HOLES

SIZE.

WASHERS SHALL BE APPROPRIATED FOR BAR GRADE AND

OR DEFORMED BARS WITH THREADED ENDS. NUTS AND

3. ANCHORS SHALL BE ASTM F1554, GRADE 105, ALL-THREAD

2. PLATE SHALL BE ASTM A572 OR A709, GRADE 50 STEEL.

REINFORCED PLATE.

1. NORMAL UPPER ELEVATION IS BELOW BOTTOM OF

VOLUME III

B J

O N

E S

C

D E

L O

N G

/0

/2

A

R O

D

6'-6"

SOLICITATION

B J

O N

E S

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

E

SHEET ID

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

W E

K

R

S I

D

E ic s p d f2 \2

\5

\B

IW

L D

V O

L -I

II

E -0

.d g n

:4

:1

P

M

C O

E -M

V R

P W

P

R O

C

/3

/2

R

C K I S

L A

N D D

IS

T R

IC

T

IL

L

IN

O

IS

R

IV

E R B

A S

IN

B .H

A R

T M

A N

N .T .S

E-001

E L E

C T

R

IC

A L G

E N

E R

A L N

O T

E

GENERAL ELECTRICAL NOTES

.P

A T

T S

C H

U L L

B

IW

L D

V O

L -I

II

E -0

.d g n

WIRE.

PROVIDED WITH A SEPARATE INSULATED GREEN GROUND

ALL NEW BRANCH, FEEDER, AND LIGHTING CIRCUITS MUST BE 16.

CONSTRUCTION. SEE STRUCTURAL DRAWINGS.

STRUCTURAL CONCRETE WORK TO FACILITATE STRUCTURAL

THE ELECTRICAL WORK MUST BE COORDINATED WITH THE 15.

TAKEN TO PROTECT CABLE ENDS FROM BEING SUBMERGED.

WATER MAY OVERTOP THE LOCK WALL. CARE MUST BE

THERE ARE OCCASIONS WHEN THE RIVER MAY FLOOD AND

THE CONTRACTOR MUST BE AWARE AND CONSIDER THAT 14.

WHICH THEY WERE ORIGINALLY INSTALLED.

INSTALL CABLES IN SAME DUCT BANK DUCT LOCATIONS IN

RESPECTIVE TERMINALS UPON THEIR REINSTALLATION.

RE-TERMINATE PERMANENT CABLES TO THEIR PERMANENT 13.

KIND AS EXISTING.

BROKEN OR LOST WIRE LABELS OR CABLE TAGS IN SAME

TAGS EXISTING ON ALL PERMANENT CABLES. REPLACE ANY

AND PROTECT IDENTIFICATION WIRE LABELS AND CABLE

TO BE WORKED WITH OR TEMPORARILY REMOVED. MAINTAIN

LOCATE AND IDENTIFY ALL PERMANENT CABLES REQUIRED 12.

PRIOR TO CONCRETE DEMOLITION.

IN THIS CONTRACT PRIOR TO REMOVING ANY CABLES AND

AREAS OF DEMOLITION OR EXCAVATION BEING ADDRESSED

BURIED AND EMBEDDED CONDUIT OR BURIED CABLE IN

PAINT OR OTHER APPROVED MEANS) THE LOCATION OF EACH

TRACE, LOCATE, IDENTIFY, AND MARK (NON-PERMANENT

PRE-CONSTRUCTION: THE CONTRACTOR MUST PHYSICALLY 11.

EXPENSE

THE LOAD AND WILL BE REPLACED AT THE CONTRACTOR'S

CABLE'S CONTINUOUS LENGTH FROM THE CABLE SOURCE TO

DAMAGED, THE CONTRACTOR MUST REPLACE THE ENTIRE

RESTORE ORIGINAL CABLE TAP SPLICES. IF A CABLE IS

CABLE WILL NOT BE ALLOWED OTHER THAN SPECIFIED TO

AND RE-TERMINATE. PERMANENT SPLICES IN EXISTING

SLACK MAY BE INADEQUATE TO CUT OUT SPLICED CABLE

CABLES AND CONDUCTOR INSULATION. EXCESS CABLE

IN SUCH A WAY AS TO PREVENT DAMAGE TO THE EXISTING

SPLICES AND SPLICE CAPS SHALL BE CAREFULLY REMOVED 10.

NON-TERMINATED, UNATTENDED CABLES OR CONDUCTORS.

MUST BE INSTALLED TO PROTECT THE ENDS OF

CONDUCTOR ENDS FROM WATER INTRUSION. SPLICE CAPS

FROM ELECTRIC SHOCK AND TO PROTECT THE CABLE AND

THE BARE CONDUCTORS AND A CABLE END TO INSULATE

SHRINK MATERIAL WHICH CAN BE PLACED OVER THE END OF

A SPLICE CAP IS A TERM USED TO DESCRIBE BLIND ENDED 9.

LOAD AT THE CONTRACTOR'S EXPENSE.

SHALL BE REPLACED IN ITS ENTIRETY FROM SOURCE TO

ANY PERMANENT CABLES DAMAGED BY THE CONTRACTOR 8.

MUST BE REPAIRED AT THE CONTRACTOR'S EXPENSE.

THE CONTRACTOR (OTHER THAN AS INDICATED IN PLANS)

ANY DAMAGE TO DUCT BANK OR EMBEDDED CONDUITS BY 7.

AND SHALL NOT BE EXPOSED.

EXISTING PERMANENT CABLE SHALL REMAIN PROTECTED

MAY BE ALLOWED TO BE EXPOSED ON THE LOCK WALL.

GALLERIES AND ONLY. TEMPORARY CABLES (IF REQUIRED)

SPLICED ENDS OF EXISTING CABLES IN HANDHOLES AND

MAINTAIN OPERATION OF EQUIPMENT, NEW CABLES SHALL BE

WHERE TEMPORARY CABLE SPLICES ARE NECESSARY TO 6.

WHERE APPROVED BY THE CONTRACTING OFFICER.

PROTECTED LOCATION AND COVERED WITH SECURED TARP

MANHOLE OR HANDHOLE OPENINGS IN THE MOST

GALLERIES MAY BE COILED AND STORED ADJACENT TO THE

HANDRAILS. CABLES THAT WILL NOT FIT IN HANDHOLES OR

EXPOSED ON THE LOCK WALL OR SECURED TO THE

HANDHOLES OR CABLE GALLERIES. DO NOT STORE CABLE

CONCRETE WORK, CABLES SHALL BE PROTECTED IN

WHERE EXISTING CABLES ARE REMOVED TO ALLOW 5.

AND CONDUITS.

SEDIMENT AND SILT IN EXISTING MANHOLES, DUCT BANKS,

BANKS. PERIODIC FLOODING MAY HAVE DEPOSITED

RE-INSTALLATION OF CABLES IN CONDUITS, DUCTS, OR DUCT

TEMPORARY CABLES AND DUCT CLEANING PRIOR TO

SEE SPECIFICATION SECTION 33 70 02 FOR SPLICES OF 4.

NOVEMBER, 2014, SECTION 12.

HEALTH REQUIREMENTS MANUAL EM 385-1-1 DATED 30

PROCEDURES IN ACCORDANCE WITH THE SAFETY AND

CONTRACTOR SHALL ADHERE TO PROPER LOCKOUT/TAG OUT 3.

2014, SECTION 11, SUBSECTION J.

REQUIREMENTS MANUAL EM 385-1-1 DATED 30 NOVEMBER,

MANHOLES IN ACCORDANCE WITH THE SAFETY AND HEALTH

CONTRACTOR SHALL PROVIDE PROTECTION FROM OPEN 2.

ELECTRICAL POWER OUTAGES.

APPROVAL FROM THE CONTRACTING OFFICER PRIOR TO ALL

CONTRACTOR MUST COORDINATE WITH AND RECEIVE 1.

RE-INSTALLED.

RACEWAY LOCATION OF ALL CABLES TO BE REPLACED OR

NOT LIMITED TO: SIZE, QUANTITY, TYPE, AND TERMINAL AND

RESPONSIBLE FOR FIELD CONFIRMING ITEMS INCLUDING, BUT

AND CABLE NAMES AND LOCATIONS. CONTRACTOR IS

PANELBOARD SCHEDULES, EQUIPMENT, CONTROL DIAGRAMS,

SEE REFERENCE DRAWINGS FOR APPROXIMATE 35.

CONTRACTION COUPLINGS MUST BE CONCRETE-EMBEDDED.

JOINTS. USE FERNCO TYPE JOINTS WHEN EXPANSION

BE INSTALLED ACROSS CONCRETE MONOLITH OR EXPANSION

CONTRACTOR MUST IDENTIFY ALL NEW CONDUITS THAT WILL

FITTING MUST BE PROVIDED WITH GROUNDING JUMPER.

CROSS CONCRETE EXPANSION JOINTS. TYPE EX CONDUIT

MUST BE PROVIDED IN LOCATIONS WHERE NEW CONDUITS

RIGID TYPE EX EXPANSION/CONTRACTION CONDUIT FITTINGS 34.

REMAINING EQUIPMENT.

AND WIRING AS REQUIRED TO MAINTAIN CONNECTION TO

CIRCUITS THAT REMAIN IN OPERATION. EXTEND CONDUIT

THE INSTALLATION OF A JUNCTION BOX TO RECONNECT

EQUIPMENT REMOVAL IN CERTAIN LOCATIONS MAY REQUIRE 33.

VERIFY EXISTING CONDITIONS.

ELECTRICAL CONDITIONS. THE CONTRACTOR MUST FIELD

THE EXISTING ELECTRICAL DRAWINGS INDICATE GENERAL 32.

REQUIREMENTS.

AS-BUILT DRAWINGS. SEE SPECIFICATIONS FOR FURTHER

LOCATIONS OF ALL CONDUITS AND CABLES ON RED-LINE

AS-BUILT DRAWINGS: CONTRACTOR MUST INCLUDE 31.

WHERE NOTED OTHERWISE .

ALL CONDUCTORS MUST BE INSTALLED IN RACEWAY, EXCEPT 30.

CONDUITS.

KEEP 120 VOLT WIRING AND 480 VOLT WIRING IN SEPARATE 29.

ONE CONDUIT.

RUN MORE THAN 9 CURRENT CARRYING CONDUCTORS IN

EXCEPT FOR NIPPLES SHORTER THAN 24 INCHES, DO NOT 28.

LOCATIONS AND CONDUIT ROUTING.

THE GOVERNMENT HAS FINAL APPROVAL ON ALL EQUIPMENT, 27.

CONCRETE ANCHORS ARE NOT PERMITTED.

WEDGE-TYPE CONCRETE ANCHORS AND POWDER-ACTUATED 26.

FASTEN CONDUIT TO ELECTRICAL JUNCTION BOXES.

INSULATED-THROAT CONDUIT HUBS SHALL BE USED TO 25.

HANDHOLES.

CONDUITS AT ALL ELECTRICAL ENCLOSURES, BOXES, AND

PROVIDE INSULATING BUSHINGS AT TERMINATION OF 24.

TO ATTACH NAMEPLATES.

SATISFY THIS REQUIREMENT. USE NON-FERROUS SCREWS

APPLICABLE). LABELING SWITCH AS S-A, S-B, ETC., DOES NOT

OPERATING VOLTAGE, AND MAXIMUM FUSE SIZE (IF

ELECTRICAL EQUIPMENT BY NAME AND FUNCTION INCLUDING

3/16 INCH HIGH LETTER TO IDENTIFY ALL MAJOR PIECES OF

NAMEPLATES MUST BE UV-RATED ENGRAVED PLASTIC WITH

BOXES, TERMINAL BLOCKS, AND NEW EQUIPMENT.

PROVIDE NAMEPLATES FOR NEW PANELBOARDS, JUNCTION 23.

OTHER CONDUIT, MACHINERY, OR PIPING.

EXPOSED CONDUITS. CONDUIT MUST NOT BE SUPPORTED BY

FITTING. USE STRAP-TYPE CONDUIT SUPPORTS FOR

CONDUIT SUPPORT WITHIN 3 FEET OF EACH BOX AND

PROVIDE SUPPORT AT EACH BOX. PROVIDE AN ADDITIONAL 22.

CONDUIT.

CONDUIT SIZE SHALL BE 3/4 INCH RIGID GALVANIZED STEEL

MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG, AND MINIMUM

AND SMALLER, AND STRANDED FOR #8 AWG AND LARGER.

CELSIUS, TYPE XHHW INSULATION. USE SOLID FOR #10 AWG

NEW CONDUCTORS MUST BE COPPER, 600 VOLT, 90 DEGREE 21.

AND CONTINUOUS RACEWAY SYSTEM.

GALVANIZED STEEL TYPE CONDUIT TO PROVIDE A COMPLETE

GALVANIZED STEEL (RGS), AND PVC COATED RIGID

FITTINGS MUST BE UL LISTED PVC SCHEDULE 40, RIGID

UNLESS OTHERWISE NOTED, ALL CONDUITS AND CONDUIT 20.

ANSI, ETC.).

WITH RELEVANT AMERICAN INDUSTRY STANDARDS (NEMA,

TERMINALS, TERMINATORS, AND WIRE LABELS MUST COMPLY

RECEPTACLES, SWITCHES, GROUNDING EQUIPMENT,

LIMITED TO: CONDUIT, WIRE, CABLES, ENCLOSURES, COVERS,

ALL NEW INSTALLED EQUIPMENT INCLUDING, BUT NOT 19.

ALL NEW ELECTRICAL EQUIPMENT MUST BE UL LISTED.18.

APPROVED SUBMITTAL.

EQUIPMENT SHALL NOT BE INSTALLED PRIOR TO AN

HAVE 30 DAYS TO REVIEW. CONTROL STANDS AND

CONTROL STAND STRUCTURES. THE GOVERNMENT SHALL

EQUIPMENT ATTACHED TO OR INSTALLED INSIDE NEW

GOVERNMENT APPROVAL FOR NEW AND REINSTALLED

THE CONTRACTOR SHALL SUBMIT A LAYOUT FOR 17.

M

C A

C K

L E

Y

WEATHER MONITORING.

AFFECTING MET STATION EQUIPMENT FOR WATER LEVEL AND

ENGINEERS, HYDRAULICS) PRIOR TO POWER DISTRUPTIONS

THE CONTRACTOR SHALL NOTIFY EC-HW (CORPS OF 49.

PROJECT.

DAMAGED AS A RESULT OF DEMOLITION WORK FOR THIS

NOTIFY THE CONTRACTING OFFICER WHERE CONDUITS ARE 48.

BE PULLED FROM THE MITER GATE ELECTRICAL ENCLOSURE.

NO TEMPORARY POWER OR CONSTRUCTION POWER SHALL 47.

NFPA 70, NATIONAL ELECTRICAL CODE.

MUST BE IN ACCORDANCE WITH THE LATEST EDITION OF

ALL FEATURES OF ELECTRICAL WORK AND INSTALLATION 46.

UPPER LOCK WALL AREAS BY LOCK AND DAM PERSONNEL.

CONTRACTING OFFICER TO ALLOW ACCESS TO NECESSARY

INSTALLATION MUST BE COORDINATED WITH THE

STAGING OF EQUIPMENT, REMOVAL, RELOCATION, AND 45.

VALVE HEATERS IN COLD TEMPERATURES.

TIMES. PROVIDE TEMPORARY CABLING FOR AFFECTED

AFFECTED TRAFFIC LIGHTING AND M.E.T. STATION AT ALL

FROM DUSK TO DAWN. PROVIDE TEMPORARY CABLING FOR

LIGHTING, NAVIGATION LIGHTING AND WIND SOCK LIGHTING

TEMPORARY CABLING FOR AFFECTED POLE MOUNTED

DAMAGE DUE TO CONCRETE SURFACING, PROVIDE

WHERE PERMANENT CABLING IS REMOVED TO PREVENT 44.

SYSTEMS IN WORK AREAS.

FUNCTIONAL LOCK POWER, CONTROL AND LIGHTING

WITH COR TO CONFIRM AND DEMONSTRATE COMPLETELY

CABLES ASSOCIATED WITH THIS PROJECT. COORDINATE

AND COMMISSION ALL LOCK POWER, CONTROL AND LIGHTING

PRIOR TO PUTTING EQUIPMENT BACK INTO SERVICE, TEST, 43.

DAMAGED OR STOLEN.

SAFE, DRY COVERED LOCATION WHERE IT CANNOT BE

SALVAGED EQUIPMENT SHALL BE CAREFULLY STORED IN A 42.

DURING RE-SURFACING WORK.

EXISTING CONCRETE ENCASED DUCTS TO BE PROTECTED

PRIOR TO RESURFACING WORK TO ENSURE AWARENESS OF

COORDINATE CABLE LOCATIONS WITH ALL DISCIPLINES 41.

POINTS TO ADD TO AS-BUILT DRAWINGS FOR THIS PROJECT.

FROM LOCKWALL AND OTHER PERMANENT REFERENCE

GOVERNMENT. PROVIDE SKETCHES WITH MEASUREMENTS

PROVIDE PHOTO AND VIDEO FILES OF PAINT LOCATORS TO

WORK, MARK ELECTRICAL DUCTS USING MARKER-PAINT, AND

PROVIDE LOCATE SERVICES IN AREAS OF BULKHEAD SLOT

PRIOR TO RESURFACING WORK, THE CONTRACTOR MUST 40.

ACCORDANCE WITH EM 385-1-1.

ACCESS INTO THE GALLERY INGRESS/EGRESS HATCH IN

FOR USE. THE CONTRACTOR SHALL PROVIDE LADDER

WORK . THE EXISTING PERMANENT LADDER IS NOT SUITABLE

THE GALLERY REQUIRES PUMPING TO ACCESS OR PERFORM

ELECTRICAL POWER FEED TO DEWATER THE GALLERY WHEN

CONTRACTOR SHALL PROVIDE A SUBMERSIBLE PUMP AND

CONTAINS WATER WHICH WILL BE PUMPED OUT. THE

ACCORDANCE WITH EM 385-1-1. THE GALLERY PERIODICALLY

REQUIREMENTS SHALL APPLY AND BE ADHERED TO IN

THE GALLERY IS A CONFINED SPACE FOR WHICH ALL SAFETY 39.

NOT PRINTED TO SCALE.

ACTUAL FIELD CONDITIONS. REFERENCE DRAWINGS ARE

NOT "AS BUILT" SO THEY DO NOT NECESSARILY REPRESENT

REFERENCE DRAWINGS. THE REFERENCE DRAWINGS ARE

REQUIRED WORK ON THIS CONTRACT IS SHOWN ON THE

INCLUDED SOLELY FOR THE CONTRACTOR'S BENEFIT. NO

REFERENCE DRAWINGS ARE DRAWINGS OF RECORD 38.

WHERE IT IS NO LONGER DISTURBED.

BETWEEN THE CABLE END AND THE ACCESSIBLE POINT

LONGER DISTURBED, AND AT POINTS NO LESS THAN 50 FEET

THE LAST ACCESSIBLE POINT WHERE THE CABLE IS NO

LOAD ENDS, AT THE END OF THE 4 DISCONNECTED CABLE, AT

DURING CONSTRUCTION. LABELING SHALL BE PROVIDED AT

AS A RESULT OF IMPROPER DOCUMENTATION OR DAMAGE

TROUBLESHOOTING, TRACING OR REPLACEMENT REQUIRED

SHALL BE RESPONSIBLE FOR RECONNECTION AND FOR ANY

FUNCTION) FOR EACH CONDUCTOR. THE CONTRACTOR

CONTROL, CABLE NUMBER, LOAD CONNECTION, AND

REMOVAL. LABELING SHALL IDENTIFY FUNCTION (POWER,

ELECTRICAL CABLES PRIOR TO DISCONNECTION OR

CONTRACTOR MUST FIELD IDENTIFY AND LABEL AFFECTED 37.

RGS.

RACEWAY EXPOSED TO WEATHER SHALL BE PVC-COATED

CONCRETE SURFACES. UNLESS NOTED OTHERWISE, ALL

CONCRETE AND 2" EXPOSED WHERE CONDUITS PENETRATE

TO PVC-COATED RGS WITH AT LEAST 2" INSTALLED IN

DUCTS SHALL BE PVC SCHEDULE 40, AND SHALL TRANSITION

UNLESS OTHERWISE NOTED, NEW CONCRETE ENCASED 36.

B

R A

D T

K E

R O

C K I S

L A

N D

IL

L

IN

O

IS

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

/0

/2

IW

L D

G R

U N

D Y C

O U

N T

Y

IL

D R

E S

D E

N I S

L A

N D L

O C

K

U P

P E

R B

U L

K H

E A

D R

E C

E S

S E

S

SOLICITATION

VOLUME III

W E

K

R

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

E

SHEET ID

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N M

A R

K D

A T

E

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

D A

T E

A P

P R

®of Engineers

US Army Corps of Engineers

US Army Corps

P R

O J E

C T C

O D

E

SHEET ID

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

A N

S I

D p w \P

W

IN

T -C

P C .E

IS

.D

S .U

S A

C E .A

R M

Y .M

IL

:C

E M

V R R o c k I s la n d D is tr ic t\

D o c u m e n ts \C iv il W o rk s \I ll in o is R iv e r

B a s in \0

D re s d e n I s la n d \B

IW

L D

U p p e r

B u lk h e a d R e c e s s e s \P la n S e ts \S h e e ts \B

IW

L D

V O

L -I

II

E -1

.d g n

:0

:5

P

M

B E

C D

M A

B

D

A T

E

.S

E-101

R

C K I S

L A

N D D

IS

T R

IC

T

IL

L

IN

O

IS

R

IV

E R B

A S

IN

E L E

C T

R

IC

A L P

L A

N

SHEET KEYNOTES

GENERAL SHEET NOTES

A1

ELECTRICAL PLAN - UPSTREAM GUIDEWALL

1 2

WINDSOCK LIGHT

NAVIGATION LIGHT

1 2 4

480V RECEPTACLE

CAMERA TOWER

LIGHT POLE BASE

MOUNTED TO OLD

DUPLEX RECEPTACLE

LIGHT STANDARD

HIGH MAST LIGHT

HANDHOLE

HANDHOLE

1 2 4

2 4

1 4

LIGHT POLE BASE

MOUNTED TO OLD

DUPLEX RECEPTACLE

480V RECEPTACLE

HANDHOLEHANDHOLEHANDHOLE

PULLBOX

0 8'SCALE : 1/16"=1'-0" 16' 32'

B .P

A T

T S

C H

U L L

B .H

A R

T M

A N

N

E1

ELECTRICAL PLAN - UPSTREAM GUIDEWALL

0 8'SCALE : 1/16"=1'-0" 16' 32'

N

D E

T A

IL

A

O

N T

H

IS

S

H E

E T

M A

T C

H L

IN

E

D E

T A

IL

E

O

N T

H

IS

S

H E

E T

M A

T C

H L

IN

E

RIVER

FLOW

FLOW

RIVER

RIVER

RIVER

B

IW

L D

V O

L -I

II

E -1

.d g n

U P

P E

R G

U

ID

E W

A L L

IDENTIFIED ON SHEET E-901, VOLUME III.

POWER FOR EQUIPMENT AS INDICATED FOR EQUIPMENT

E-101 AND VOLUME III, SHEET E-101. PROVIDE TEMPORARY

RECONNECTION WORK IDENTIFIED IN VOLUME I, SHEET

SHEET ARE AFFECTED BY CABLE DISCONNECTION AND

LIGHTING, RECEPTACLES & CAMERAS, SHOWN ON THIS 5.

OF CONDUCTORS SHALL BE ALLOWED.

REPLACED AT THE CONTRACTORS EXPENSE. NO SPLICING

RE-SURFACING WORK. ANY DAMAGED DUCTS WILL BE

GUIDEWALL DUCT-BANK SHALL BE PROTECTED DURING

EXISTING MANHOLES (HAND-HOLES) AND CONDUITS IN

COORDINATE WITH ALL DISCIPLINES TO ENSURE THAT 4.

RACEWAYS, CABLES AND CONNECTIONS DRAWINGS.

SEE REFERENCE DRAWINGS FOR ORIGINAL CONSTRUCTION 3.

SEE NOTES ON SHEET E-001.2.

ALL WORK SHOWN ON THIS SHEET IS PART OF OPTION "F".1.

(TYPICAL)

IN CONCRETE EMBEDDED DUCT BANKS

CABLES (DL2, DP8, P-12, L2-1 & L2-9)

(TYPICAL)

IN CONCRETE EMBEDDED DUCT BANKS

CABLES (DL2, DP8, P-12, L2-1 & L2-9)

DUCT BANKS (TYPICAL)

IN CONCRETE EMBEDDED

CABLES (P-12 & L2-9)

2 4

2 4

2 4

(TYPICAL)

IN CONCRETE EMBEDDED DUCT BANKS

CABLES (DL2, DP8, L2-1 & L2-9)

EMBEDDED DUCT

IN CONCRETE

CABLE (L2-9)

RESURFACING AREA (TYPICAL)

SHADING DEPICTS CONCRETE

RESURFACING AREA (TYPICAL)

SHADING DEPICTS CONCRETE

ATTACHED TO HANDRAIL

CABLE (L2-1) IN 3/4" RACEWAY

2 4

RIGID GALVANIZED RACEWAY

IN SURFACE MOUNTED 3"

CABLES (DL2 & DP8)

(TYPICAL)

EMBEDDED DUCT BANKS

CABLE (L2-1) IN CONCRETE

RECEPTACLE

DUPLEX

(TYPICAL)

EMBEDDED DUCT BANKS

CABLE (L2-1& L2-9) IN CONCRETE

DUCT

IN CONCRETE ENCASED

CABLES (DL2 & L2-9)

(TYPICAL)

EMBEDDED DUCTS

CABLE (L2-1) IN CONCRETERACEWAY

MOUNTED

SURFACE

DUCT &

EMBEDDED

IN CONCRETE

CABLE (DP8)

RIGID CONDUIT

SURFACE MOUNTED

CABLE (DL2) IN 3"

MOUNTED RIGID CONDUIT)

CABLE (DL2) IN 3" SURFACE

D E

T A

IL

A

O

N V

O L

U M

E I S

H E

E T E -1

M A

T C

H L

IN

E

HANDHOLE MH3

RESURFACING WORK.

6. REINSTALL EXISTING EQUIPMENT UPON COMPLETION OF

WORK.

NOT BE SUBJECT TO DAMAGE DURING RESURFACING

BOLTS AND EQUIPMENT IN A LOCATION WHERE IT WILL

UNBOLT EQUIPMENT, CAREFULLY REMOVE AND STORE 5.

AND RETERMINATE.

BACK THROUGH CONDUIT TO ASSOCIATED EQUIPMENT

DAMAGE CONDUIT OR CABLING, PULL STORED CABLES

4. UPON COMPLETION OF WORK THAT CAN POTENTIAL

REINSTALLED IN THE SAME LOCATION.

HANDHOLE "MH3" AND LIGHTING EQUIPMENT TO BE

RACEWAY WITH 1" PVC COATED RACEWAY BETWEEN

DEMOLISH AND REPLACE 1" CONCRETE EMBEDDED 3.

CABLES INSIDE A HANDHOLE OR GALLERY.

AREA AND AS NEEDED TO CAREFULLY COIL AND PROTECT

REQUIRED TO REMOVE CABLES FROM THE RESURFACING

MOISTURE. PULL CONDUCTORS BACK AS FAR AS

AFTER WORK IS PERFORMED, AND SEAL ENDS FROM

END. LABEL CONDUCTORS TO ASSURE RECONNECTION

CONDUCTORS FROM EXISTING EQUIPMENT AT THE LOAD

2. PRIOR TO CONCRETE DEMOLITION, DISCONNECT

DEMOLITION .

AND CABLES ARE NOT DAMAGED DURING CONCRETE

ADDITIONAL CARE SHALL BE TAKEN TO ASSURE CONDUITS

AND IN SKETCHES TO CLEARLY IDENTIFY AREAS WHERE

EMBEDDED ELECTRICAL. DOCUMENT ROUTING IN PHOTOS

MEASURE, MARK CONCRETE AND RECORD ROUTING OF

ELECTRICAL ROUTING SHOWN IS APPROXIMATE. LOCATE, 1.

M

C A

C K

L E

Y

2 4

2 4

2 4

2 4

B

R A

D T

K E

R O

C K I S

L A

N D

IL

L

IN

O

IS

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

/0

/2

W E

K

R

IW

L D

G R

U N

D Y C

O U

N T

Y

IL

D R

E S

D E

N I S

L A

N D L

O C

K

U P

P E

R B

U L

K H

E A

D R

E C

E S

S E

S

SOLICITATION

VOLUME III