Site visit information has been added to the PWS
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W912DY-16-T-0105-05.pdf | ||
| Attachment_1_-_TV_Locations_4-6-16_Rev2.xlsx | XLSX spreadsheet | |
| Q A_2__W912DY-16-T-0105.pdf | ||
| W912DY-16-T-0105-04.pdf | ||
| W912DY-16-T-0105-03.pdf | ||
| TV_Floor_Plans.pdf | ||
| Copy_of_QA_W912DY-16-T-0105_-_Revised20160330.xlsx | XLSX spreadsheet | |
| Attachment_1_-_TV_Locations_3-31-16_Rev2.xlsx | XLSX spreadsheet | |
| A07.23_W912DY16T0105-02.pdf | ||
| W912DY16T0105.pdf | ||
| Attachment_1_-_TV_Locations_3-02-16(2).xlsx | XLSX spreadsheet |
Show all 11
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The Performance Work Statement Section 2.2 is herby revised to read: 2.2 A site visit w ill be scheduled for three business days before the due date of RFQ/RFP. The site visit is scheduled for Monday 28 March 2016 at 0900 CST. Location 4820 University Square Huntsville, AL 35816; the points of contact are as follow s:
Project Manager: Jerad McIntyre Email: Jerad.R.Mcintyre.civ@mail.mil Technical Manager: Chris Robbins Email: Christopher.D.Robbins@usace.army.mil Please send an email to the points of contacts above if you plan to attend.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 9
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912DY-16-T-0105
X 9B. DATED (SEE ITEM 11)
21-Mar-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
U0001
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
24-Mar-2016
CODE
US ARMY ENGINEERING & SUPPORT CENTER
CEHNC-CT
4820 UNIVERSITY SQUARE
HUNTSVILLE AL 35816-1822
W912DY 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912DY-16-T-0105
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
The following have been modified:
PWS
Performance Work Statement (PWS)
CEHNC TV/Power/Comm/Data Install Amendment 01, 03/24/2016
Date 03/02/2016
1.0 Synopsis: The Contractor shall furnish and install TVs/Monitors, power receptacles, CATV outlets and computer data input outlets as listed in attachment 1 at the Engineering and Support Center, Huntsville, Alabama.
The Contractor shall provide a fully functional and complete working system in compliance with activity specific requirements itemized in the PWS.
2.0 Specific Work To Be Accomplished:
2.1 Provide new power and communications cabling, outlets/connection points, TV mounting hardware, mounting and connection service for new and Government-furnished TV/monitors. Provide and install Video Teleconference systems.
2.1.1 Equipment shall be installed in the rooms shown in Attachment 01. Specific locations within rooms shall be as directed. Minimal furniture moving may be required for some locations.
2.1.2 Cabling shall be installed per BICSI 568 TDMM, as applicable. Cables shall be rated for the environment they will be installed in. All cabling within walls shall be in metal conduit. All connectors shall be gold plated. No cabling shall be installed within six feet of 2G000.
2.1.3 CATV cabling shall be RG6 minimum.
2.1.4 PAO data cables shall be Cat 6 routed to the comm room on that floor to the designated rack.
Supply 100 additional 10 ft. Cat 6 cables.
2.1.5 TV/monitors shall be LED type smart TVs with wifi and RJ45 Ethernet port, minimum screen resolution 4k, minimum 2 HDMI inputs, VESDA wall mount standard 400mm x 400mm.
2.1.6 Install TV/monitors at locations as directed. TV/monitor mounts shall allow units to be viewed by the intended audience. All TV/monitor inputs/outputs/controls shall be accessible as mounted. Install TV/monitor signal outlets, CATV outlets and power receptacles behind TV/monitor. Provide power surge protection at each TV/monitor location with minimum 2 receptacles plus 60 additional surge protectors.
Receptacles shall run power cables parallel to the wall for ease of plugging/unplugging.
2.1.7 Provide a computer data outlet next to user’s LAN outlet. Connect this outlet to a computer data outlet at the TV/monitor. Computer input data outlets shall use HDMI Type A jacks. Provide one six foot HDMI patch cord for each HDMI outlet. Provide a HDMI switch to switch from the desk monitor to the wall mounted TV/monitor. Provide HDMI adaptors where required by office computer outputs to provide video and audio to the TV/monitor. Provide HDMI to VGA/audio adaptors for all conference rooms.
HDMI cables and adaptors shall provide full 1080p video resolution and be HDMI certified.
2.1.8 Label all communications cabling on both ends of the cable run. Route the end of the communications cabling in all communications rooms to the farthest point on the rack to ensure the cables can be connected to any location on it. In offices, allow three feet slack above wall at each end of cable.
Support all cabling above ceiling. Do not lay cabling on ceiling. Route cabling within walls unless otherwise noted (see Attachment 1). There shall be no surface mounted cabling except as noted.
2.1.9 PAO data installs shall include a Cisco Edge 340 digital media player using Cat 6 and HDMI connections.
2.1.10 Video Teleconference systems provided shall be CISCO Telepresence MX300. Monitors shall be wall mounted.
2.1.11 Relocate one circuit from the third floor power panels and two circuits from the second floor power panels to the first floor UPS as directed.
2.1.12 Ensure the added load to the building power system is available within the system. Assume TV/monitors at 63 watts. Provide additional power circuits and panels as required. All electrical work shall be in accordance NFPA 70.
2.1.13 All cabling and outlets shall be tested and certified. Provide a test report showing all results.
2.1.14 All direction mentioned in Section 2 shall come from the KO or the COR.
2.2 A site visit will be scheduled for three business days before the due date of RFQ/RFP. The site visit is scheduled for Monday 28 March 2016 at 0900 CST. Location 4820 University Square Huntsville, Al 35816; the points of contact are as follows:
Project Manager: Jerad McIntyre Email: Jerad.R.Mcintyre.civ@mail.mil Technical Manager: Chris Robbins Email: Christopher.D.Robbins@usace.army.mil Please send an email to the points of contacts above if you plan to attend.
3.0 Schedule: The Contractor shall develop, maintain, and submit for Government approval, an integral master project schedule identifying critical path events for all requirements to be performed by the Contractor IAW this PWS. The completion date for this contract is to be within 60 days from contract award.
4.0 Period of Performance: The Contractor shall develop and submit a detailed project schedule showing all milestone events required by this PWS. The schedule shall adhere to Period of Performance (POP) as awarded.
POP extension requests are not guaranteed and may require consideration from the Contractor depending upon the circumstances of the request. If a specific delivery date is required by the Government, it will be specified in the Request for Proposal (RFP). Otherwise, the Contractor shall propose a period of performance (POP) in response to the level of effort required to fulfill the requirements of the RFP. This POP may be negotiated prior to award of the contract. The government reserves the right to award a POP date beyond the contractor’s proposed date. These days are for government close out actions and are not to be interpreted as additional time or float for the contractor to use for project completion.
5.0 Payments:
5.1 Payment will be IAW with the following schedule. All days are business days.
Milestone Payment at Completion of Event (% of Contract Price)
Description % Required Date
Government acceptance of Accident Prevention Plan (APP) 5 Submitted 5 days after award
Government acceptance of Project Schedule 5 Submitted 5 days after award
Project Installation Activities 85 Per approved schedule
Delivery and Government acceptance of all other documentation required by the PWS
5 Per approved schedule
Total 100
5.2 Sequential Progression. No work shall be accepted and paid for unless all prior events have been successfully completed.
6.0 Invoicing Instructions:
All invoices must be submitted electronically for technical review and payment. Electronic invoice submissions must be created in black and white in Adobe's Portable Document Format (PDF). The contractor should submit invoices to each of the following email addresses:
Christopher.D.Robbins@usace.army.mil Jerad.R.McIntyre@usace.army.mil SPPInvoice@usace.army.mil
Note: Invoices must match purchase order/contract in description. Defective/deficient invoices will be returned.
Invoices submitted for payment by Contractors shall contain the following minimum information:
1) Name and address of the contractor
2) Invoice date and number
3) Contract number, contract line item number and if applicable, the order number
4) Description, quantity, unit of measure, unit price and extended price of the item delivered
5) Shipping and payment terms
6) Terms of any discount for prompt payment offered
7) Name and address of official to whom payment will be sent
Payments will be made after submission of a proper invoice and after the Government accepts the services.
7.0 Safety Compliance Requirements: Contractor shall execute all work IAW the latest version of the US Army Corps of Engineers Safety and Health Requirements Manual, EM 385-1-1.
http://www.usace.army.mil/SafetyandOccupationalHealth/SafetyandHealthRequirementsManual.aspx
Accident Prevention Plan (APP) for Limited Scope. The Contractor shall be required to submit a Corporate Accident Prevention Plan to the Contracting Officer and Contracting Officer Representative within five business days after initial award of the contract. The APP shall address applicable items listed in Appendix A of the US Army Corps of Engineers Safety and Health Requirements Manual (EM 385-1-1) in addition to the other applicable requirements of EM 385-1-1 and OSHA requirements. An APP is, in essence, a safety and health policy and program document. The plan shall provide enough information to be generally applicable to all of the work items listed above. The APP is a document that details how the safety and health requirements of OSHA; other regulatory codes and documents; and the U. S. Army Corps of Engineers Safety and Health Requirements Manual, EM 385-1-1 are to be accomplished. No work shall be performed until the APP has been reviewed and accepted by CEHNC.
8.0 Quality Control: The Contractor shall establish and maintain a complete Quality Control Plan (QCP) to verify that contract performance is achieved as specified. A copy of the plan or any updates to the plan shall be provided to the Contracting Officer within 10 business days upon request. Personnel performing quality control functions shall be identified to the COR and given sufficient responsibility, authority, and organizational freedom to identify and evaluate quality problems, initiate, recommend, or provide solutions. The program shall include, but not be limited to, the following:
8.1 Quality Control System. A Quality Control System (QCS) covering all services performed by this contract which must specify the areas to be inspected on either a scheduled or unscheduled basis and how often inspections will be accomplished and documented.
8.2 Quality Assurance shall be performed by visual inspection.
9. Points of Contact:
Project Manager:
Name: Jerad McIntyre Phone: 256-895-1045 Email:
Jerad.R.Mcintyre.civ@mail.milmailto:Will.whit e@usace.army.mil Technical Manager:
Name: Chris Robbins Phone: 256-895-1567 Email:
Christopher.D.Robbins@usace.army.milmailto:Will.white @usace.army.mil Contracting Officer:
See Award Documents
10.0 Security: All contractor personnel shall read applicable security regulations, to be provided by the government, to familiarize them with the government’s guidance on security.
10.1 Access and General Protection/Security Policy and Procedures. All contractor and all associated sub-contractors employees shall comply with applicable installation, facility and area commander installation/facility access and local security policies and procedures (provided by government representative). The contractor shall also provide all information required for background checks or background investigation and to meet installation/facility access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this contract, should the Force Protection Condition (FPCON) at any installation or facility change, the Government may require changes in contractor security matters or processes.
10.2 Contractors will be escorted in areas where they may be exposed to classified and/or sensitive materials and/or sensitive or restricted areas. All contract employees, including subcontractor employees who are not in possession of the appropriate security clearance or access privileges, will be escorted in areas where they may be exposed to classified and/or sensitive materials and/or sensitive or restricted areas.
10.3 The Contractor must pre‐screen Candidates using the E‐verify Program (http://www.dhs.gov/E‐Verify) website to meet the established employment eligibility requirements. The Vendor must ensure that the Candidate has two valid forms of Government issued identification prior to ensure the correct information is entered into the E‐verify system. An initial list of verified/eligible Candidates must be provided to the COR no later than three business days after the initial contract award.
11.0 Prosecution and Completion of Work:
11.1 The Contractor shall prosecute the work under the direction of a responsible representative approved by the Government. The company officer or representative shall be designated as the Contractor’s Project Manager and shall be responsible for complete coordination of all work under this contract. All work shall be accomplished with adequate internal controls, quality assurance processes, and review procedures established by the Contractor to ensure technical accuracy and eliminate conflicts, errors, and omissions. The Government may elect to provide third party technical inspection.
11.2 The contractor is required to pay wage rates in accordance with the criteria set forth below:
11.2.1 Wage Rate Requirements (Construction) (WRRC) shall be utilized for construction based labor efforts.
These activities include but are not limited to high/medium voltage wiring, excavation, trenching, removing/repairing walls, flooring, framing, foundation work, masonry, plumbing, lighting replacement, demolition (if other construction work is to follow), painting, replacement of boilers/chillers/air handling units (not including purchase of equipment), installation of new fire alarm systems, and any other work required to be performed by a construction trade.
11.2.2 Service Contract Labor Standards (SCLS) wage rates shall be utilized for non-professional service-based labor efforts if the work is predominantly services. Service activities include but are not limited to the design, project oversight, commissioning, engineering, meter installation, programming, test and balancing, survey, low voltage wiring not requiring an electrician, control system components (motors, actuators, sensors, controls, etc.), repairs to fire alarm systems/chillers/boilers/air handling units, repair/replacement to other ancillary equipment, installation/repair of electronic security systems, and any other work of a services nature that is not required to be performed by a construction trade.
11.3.3 SCLS/WWRC Wage Rate Applicability by Location: WWRC wage rates are only applicable within the United States. SCLS rates are applicable within the United States, Northern Mariana Islands, Guam, Puerto Rico, American Samoa, Johnson Island, the U.S. Virgin Islands, Wake Island, and Outer Continental Shelf Lands.
12.0 Final Invoice Instruction:
A Release of Claims form must be completed and returned in order for the final invoice to be processed. Please note that if your company uses a raised seal as a form of authenticity, it should be included either on the Release of Claims form or on a separate page following the form.
Notation on the invoice identifying it as a Final Invoice is also required.
Release of Claims form is listed under attachment 4.
Attachment 1
1.0 Additional details. See TV Locations excel sheet.
Attachment 2 Quality Assurance Surveillance Plan (QASP)
1.0 This Performance-Based Quality Assurance Surveillance Plan (QASP) has been developed pursuant to the requirements of the PWS. This plan sets forth procedures and guidelines that the USACE will use in evaluating the technical and safety performance of the Contractor. Performance requirements are furnished in the PWS so that the Contractor will be aware of the methods that the Government will employ in evaluating their performance on this contract.
2.0 Methodologies Used to Monitor the Contractor’s Performance: Even though the Government, through its CORs and QA’s, will be monitoring the contractor’s performance on a continuing basis, the volume of tasks performed by the contractor makes technical inspections of every task and step impractical. Accordingly, USACE will use the QASP as the basis for monitoring the contractor’s performance.
3.0 Quality Assurance Surveillance Activities: In general, the work will be evaluated in terms of how well the requirements of the contract are satisfied, the extent to which the work performed follows the approach found in the contractor’s technical proposal, clarity of documentation, and timeliness of scheduled task accomplishment. At the discretion of the COR and approval of the Contracting Officer, other government officials may be asked to evaluate a particular deliverable or set of deliverables.
4.0 Quality Assurance Reporting Forms: The forms used to document surveillance activities include Contractor’s Progress Report, Memorandums for Record, ENG 4025s, and/or other documentation as deemed appropriate by the Contracting Officer or COR. Nonconformance will be documented on a Corrective Action Request (CAR). Non-conformances are documented at the discretion of the person conducting the surveillance activity, but should be fair and reasonable. Each CAR will be annotated as a Critical nonconformance, Major nonconformance, or Minor nonconformance. CARs will be provided to the Contracting Officer for distribution to the contractor. The contractor will be required to correct life/safety issues immediately. All other CARs will provide a reasonable suspense date for the contractor to review and take appropriate action, usually 10 calendar days. The contractor is required to provide written responses to all CARs.
5.0 Performance Requirements Summary (PRS): The performance evaluation of the contractor will be based on performance metrics. Performance for each evaluation criteria will be scored as superior, acceptable, marginal, or unacceptable. Evaluation will be based on the criteria listed in the table below and measured against objectives established in each individual task order: quality, timeliness, safety, conformance, and management.
Performance Standard
Superior Performance Acceptable Performance Marginal Performance Unacceptable Performance
Quality Contractor provides unique solutions for the requirements in the PWS.
No government direction is required.
Contractor meets the requirements in the PWS, with little to no government direction.
Contractor does not meet the requirements in the
PWS.
Contractor does not meet the requirements in the PWS, and the government cannot accept the work.
Timeliness Contractor provides acceptable deliverables resulting in overall project completion 10% ahead of schedule.
Contractor provides deliverable according to the schedule.
deliverable behind the project schedule, but not causing a delay in the overall schedule.
deliverable behind the project schedule resulting in delay.
Performance delays >10% deviation from project schedule.
Safety No reportable or lost time accidents.
No reportable or lost time accidents above industry standards.
Reportable lost time accidents above industry standard; no regulatory citations.
Contractor has lost time accidents above industry standard and received regulatory citation for noncompliance.
Management Labor management is optimally effective and ensures complete compliance with requirements of the PWS.
Planning and control of labor is mostly effective and ensures sound compliance with requirements of the
PWS.
Significant lapse in planning and/or control of labor which requires some rework or minor delays to the project.
Multiple lapses in planning and/or control of labor, which requires KO or COR intervention to resolve and has a significant impact on project milestones and schedule.
The contract shall have the following incentives:
Positive
1) Positive performance valuation
2) Report of good performance in the Contractor Performance Assessment Reporting System (CPARS).
Negative
1) Negative Performance evaluation
2) Report of poor performance in CPARS
3) Possible Termination for Default
Attachment 3
Antiterrorism/Operations Security (AT/OPSEC) Requirements
The table below identifies specific AT/OPSEC requirements in accordance with OPORD 2013-74 dated 19 MAR 2014. Contractors shall comply with all AT/OPSEC requirements marked "Yes" in the table below.
Item Yes N/A Requirement
1 X
AT Level 1 Training: All Contractor employees, to include subcontractor employees, requiring access to Army installations, facilities and controlled access areas shall complete AT Level I awareness training within 30 calendar days after contract start date or effective date of incorporation of this requirement into the contract, whichever is applicable. The Contractor shall submit certificates of completion for each affected Contractor employee and subcontractor employee, to the COR or to the contracting officer within 5 calendar days after completion of training by all employees and subcontractor personnel. AT Level I awareness training is available at the following website: https://atlevel1.dtic.mil/at.
2 X AT Awareness Training for US Based Contractor Personnel Traveling Overseas: All US based Contractor employees and associated subcontractor employees traveling overseas will receive the government provide AOR specific AT awareness training prior to departure.
3 X
Access and General Protection/Security Policy and Procedures: Contractor and all associated subcontractors employees shall comply with applicable installation, facility and area commander installation/facility access and local security policies and procedures. The Contractor shall also provide all information required for background checks to meet installation access requirements to be accomplished by installation Provost Marshal Office, Director of Emergency Services or Security Office. Contractor workforce must comply with all personal identity verification requirements as directed by DOD, HQDA and/or local policy. In addition to the changes otherwise authorized by the changes clause of this task order and base contract, should the Force Protection Condition (FPCON) at any individual facility or installation change, the Government may require changes in Contractor security matters or processes.
4 X iWatch and/or CorpWatch Training: The Contractor and all associated subcontractors shall brief all employees on the local iWATCH, Corps Watch, or See Something, Say Something program (training standards provided by the requiring activity ATO). This local developed training will be used to inform employees of the types of behavior to watch for and instruct employees to report suspicious activity to the COR. This training shall be completed within 30 calendar days of task order award and within 30 calendar days of new employees commencing performance with the results reported to the COR NLT 30 calendar days after completion of the training.
5 X
Contractor Employees Requiring Access to Government Information Systems: All Contractor employees with access to a government information system shall be registered in the Army Training Certification Tracking System (ATCTS) at commencement of services, and shall successfully complete the DOD Information Assurance Awareness prior to access to the information systems and then annually thereafter.
6 X
OPSEC Standing Operating Procedure/Plan. Contractor shall develop an OPSEC SOP/Plan within 90 days of task order award. The OPSEC SOP/Plan shall be reviewed and approved by the RA OPSEC Officer. The SOP/Plan shall include the government's critical information, why it needs to be protected, where it is located, who is responsible for it, and how to protect it. In addition, the Contractor shall identify an individual who will be an OPSEC Coordinator.
7 X OPSEC Training: All new Contractor employees shall complete Level I OPSEC training within 30 calendar days of their reporting for duty. Additionally, all Contractor employees shall complete annual OPSEC awareness training.
8 X
Information Assurance (IA)/Information Technology (IT) training: All Contractor employees and associated subcontractor employees shall complete the DoD IA awareness training before issuance of network access and annually thereafter. All Contractor employees working IA/IT functions shall comply with DoD and Army training requirements in DoDD 8570.01, DoD 8570.01-M and AR 25‐2 within six months of employment.
9 X
Information Assurance (IA)/Information Technology (IT) certification: All Contractor employees supporting IA/IT functions shall be appropriately certified upon contract IAW DoD 8570.01-M, DFARS 252.239-7001 and AR 25-2. The baseline certification as stipulated in DoD 8570.01-M shall be completed upon task order award.
10 X
Contractors Authorized to Accompany the Force: Contractor employees shall ensure the following AT/OPSEC requirements are meet prior to deploying personnel authorized to accompany U.S. Armed Forces outside the United States: required compliance with laws and regulations, pre‐deployment requirements, required training (per combatant command guidance), and personnel data required.
11 X
Performance or Delivery in a Foreign Country: All non-local contracting personnel shall comply with theater clearance requirements and allow the combatant commander to exercise oversight to ensure the Contractor’s compliance with combatant commander and subordinate task force commander policies and directives.
12 X
Handling and Access to Classified Information: The Contractor shall comply with the Security Agreement (DD Form 441), including the National Industrial Security Program Operating Manual (DoD 5220.22-M), any revisions to DOD 5220.22‐M and Army Regulation 380‐49, Industrial Security. The DD254 will be attached with the task order.
13 X
Access to Classified and/or Sensitive Materials and/or Sensitive or Restricted Areas: Contract employees, including subcontractor employees who are not in possession of the appropriate security clearance, shall be escorted in areas where they may be exposed to classified and/or sensitive materials and/or sensitive or restricted areas.
14 X
Facility Clearance and Individual Clearances at the Appropriate Level: Prime Contractor shall have a Facility Clearance (FCL) at the appropriate level (IAW the NISPOM DOD 5220.22-M and AR 380-49) prior to the start of the task order period of performance. Contractor personnel performing work under this task order shall have the required security clearance, per AR 380- 67, at the appropriate level at the start of the period of performance. Security Clearances and FCL requirements are required to be maintained for the life of the contract IAW the DD254 attached to the contract. If no FCL, the supporting Government Contracting Activity will sponsor the prime contract company in obtaining the FCL.
15 X
E-Verify: Contractor shall pre-screen Candidates using the E-verify Program (http://www.dhs.gov/E-Verify) website to meet the established employment eligibility requirements. Contractor shall ensure that the Candidate has two valid forms of Government issued identification prior to ensure the correct information is entered into the E-verify system.
An initial list of verified/eligible Candidates shall be provided to the COR no later than 3 business days after the initial award.
16 X
Armed Security Guards: Contractor and all associated subcontractor employees shall comply with applicable installation, facility and area commander installation/facility policies and procedures on storing weapons and ammunition IAW AR 190‐11 (provided by government representative).
(End of Summary of Changes)