This is Standard Form 30, Amendment 0006 to solicitation W912DS26BA006 for the Gas Alley Access Control Point (ACP) project at Fort Drum, New York, issued by the U.S. Army Corps of Engineers (USACE), New York District. The amendment is effective March 23, 2026, and was issued by contracting officer Orlando Nieves. The bid opening date remains March 31, 2026, at 2:00 P.M. EST and is not extended.
The amendment revises five drawings (ED-102, ED-103, E-202, E-203, and E-303) and adds Drawing Addendum 1 and a PFAS Addendum. No specification sections are added, deleted, or revised. The amendment responds to bidder questions regarding two key issues: (1) passive cable barrier modifications for corners less than 40 feet, clarifying that any non-preapproved barriers must undergo crash rating testing by the USACE Protective Design Center, with acceptable gaps not exceeding 4 feet and overlaps permitted; and (2) sanitary force main (FM-1) sizing, confirming that FM-1 should be revised from 4-inch HDPE to 6-inch HDPE with 6-inch fittings. Wage rates have also been updated. Bidders must acknowledge receipt of this amendment prior to the bid opening date and time using one of three specified methods or face rejection under FAR 14.304.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:
(a) By completing items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of theoffer submitted;
or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER.
If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER
NUMBER IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print) 16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
15B. CONTRACTOR/OFFEROR
(Signature of person authorized to sign)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA
(Signature of Contracting Officer)
16C. DATE SIGNED
Previous edition unusable STANDARD FORM 30 (REV. 11/2016) Prescribed by GSA FAR (48 CFR) 53.243
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES
2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)
6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE
8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X) 9A. AMENDMENT OF SOLICITATION NUMBER
9B. DATED (SEE ITEM 11)
10A. MODIFICATION OF CONTRACT/ORDER NUMBE
10B. DATED (SEE ITEM 13)
CODE FACILITY CODE
J 1 3
0006 23 MAR 2026 101051
W912DS
W2SD ENDIST NEW YORK
KO CONTRACTING DIVISION, 26 FEDERAL PLAZA ROOM 16 300
NEW YORK, NY 10278-0004
UNITED STATES
ORLANDO NIEVES, EMAIL: ORLANDO.NIEVES@USACE.ARMY.MIL TELEPHONE:
(917) 790-8078
SCD: PAS:
W912DS26BA006
30 JAN 2026
SEE SECTION G - CONTRACT ADMINISTRATION DATA
The purpose of Amendment 0006:
1) Bid opening remains 31-March-2026 at 2:00 P.M. EST.
2) Respond to Bidder Request for information. For information Only.
3) Drawing Addendum 1, have been added. See Attached.
4) Drawings ED-102, ED103, E-202, E-203, E-303, have been revised and Reissued. See Attached.
5) Update Wage Rates. See Attached, MATTHEW LUBIAK
23 MAR 2026
Fort Drum, NY Gas Alley Access Control Point ACP
W912DS26BA006
Amendment 0006
AMENDMENT 0006 to DRAWINGS and SPECIFICATIONS for Gas Alley Access Control Point, Fort Drum NY.
TO OFFERORS
The following changes shall be made to the drawings and specifications.
DRAWINGS
1. The following DRAWINGS have been REVISED but NOT REISSUED:
- None
2. The following DRAWINGS have been REVISED and REISSUED:
- ED-102
- ED-103
- E-202
- E-203
- E-303
3. The following DRAWINGS have been ADDED:
- Drawing Addendum 1
- PFAS Addendum
4. The following DRAWINGS have been DELETED:
- None
SPECIFICATIONS
1. The following SPECIFICATION SECTIONS have been ADDED and are provided in their entirety herein:
- None
2. The following SPECIFICATIONS SECTIONS have been DELETED in their entirety:
- None
3. The following SPECIFICATIONS SECTIONS have been REVISED and REISSUED:
4. None The following SPECIFICATIONS have been REVISED but NOT REISSUED:
PROPOSER’S QUESTIONS AND GOVERNMENT REPLY
Questions that may be of general interest to all Offerors and/or the Government and that are not readily answered by the proceeding changes will appear below. These questions may have been paraphrased or altered to represent several questions regarding the same subject and/or simply revised to clarify and simplify the question(s). Questions and answers are issued to the Offerors “for information only” and do not revise the solicitation, plans or specifications.
Question 1 The passive cable barrier is specified as “configuration identical to the as-tested”. There are several corners on the cable barrier system that are less than 40’. The shortest m50 p1 cable barrier on the DOD list is 40’. Is it acceptable for a company make site specific modifications for corners?
Answer 1 If a contractor modifies a preapproved barrier length, that barrier is no longer preapproved. Any barriers that are not preapproved will need to undergo testing to prove that it meets the required crash ratings. Acceptance of test results can only be approved by the USACE Protective Design Center. The passive barrier linework on the plans is theoretical and the final layout can (and is expected to be) modified. The contractor must submit the final layout shop drawings for approval. Overlaps of barriers is acceptable. Gaps in the barrier can be no more than 4’ to achieve compliance.
Question 2 Reference Drawings C-102 and C-106, the new sanitary force main relocation (FM1) is notated to be 4” HDPE with 4” fittings and the profile of FM-1 on C-106 notates tie-ins to ‘existing 4” HDPE Sanitary Force Main’ at the ends. Further past the tie-in locations on the C- 102 plan, the existing sanitary force main is labeled as 6” HDPE. Please confirm for bidding purposes that 4” HDPE is the correct sizing for FM1?
Answer 2 FM-1 should be revised to 6” HDPE and 6” fittings.
--END--