This document is a pre-solicitation notice for the Renovation of Building 99 at Pituffik Space Base in Greenland. The U.S. Army Corps of Engineers New York District intends to issue a solicitation for a firm-fixed-price contract to recapitalize the existing three-story dormitory. The work involves site work, utilities, roof and exterior repairs, and complete interior renovation to accommodate U.S. military personnel in a 2+2 configuration with shared bathrooms. The facility lacks fire suppression and has inadequate living quarters. The estimated cost range is $25,000,000 to $100,000,000, with work anticipated to begin in FY 2025 over approximately 3 years. Liquidated damages of $5,000 per day will be assessed for delays. This procurement is restricted to Danish and Greenlandic firms only.

View the file

Other files

File Type Posted
ATTACHMENT 5.docx DOCX document
Amendment 0001.pdf PDF
ATTACHMENT 2.docx DOCX document
W912DS25R0002.pdf PDF
Package 1-Pituffik SB_B99 Reno DB RFP - RTA.pdf PDF
Package 2-Pituffik SB B99 Reno Appendices RTA.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Design-Build Request for Proposal

Package 3 - CID, SID & FFE

Repair Dormitory Building 99 Pituffik Space Base, Greenland

19 September 2024

FINAL SUBMISSION

BAUTISA

Snapshot

BAUTISA

Rectangle

BAUTISA

Snapshot

TABLE OF CONTENT:

JACOBS / EWINGCOLE | PITUFFIK SPACE BASE GREENLAND REPAIR DORMITORY BUILDING 99 – RENOVATIONS © JACOBS | © EWINGCOLE 2024

SECTION 1 - GENERAL INFORMATION

1.1 Statement of Design Directives

SECTION 2 – STRUCTURAL INTERIOR DESIGN

2.1 Room Finish Schedule and Interior Finish Material Key

I-001 Interior Finish Schedules

2.2 Material Cutsheets

2.3 Structural Interior Design (SID) Manufacturer Summary List

SECTION 3 – FURNITURE, FIXTURES & EQUIPMENT

3.1 Overall Furniture Plans

I-101 First Floor Furniture Plan I-102 Second Floor Furniture Plan I-103 Third Floor Furniture Plan

3.2 Enlarged Furniture Plans & Furniture Schedule

I-401 Enlarged Furniture Plans & Furniture Schedule

3.3 Furniture, Fixtures & Equipment (FF&E) Manufacturer Summary List

SECTION 4 – FURNITURE SPECIFICATION SHEETS

SECTION 1 – GENERAL INFORMATION:

JACOBS / EWINGCOLE | PITUFFIK SPACE BASE GREENLAND REPAIR DORMITORY BUILDING 99 – RENOVATIONS © JACOBS | © EWINGCOLE 2024

1.1 Statement of Design Objectives

The Concept Comprehensive Interior Design (CID) package for the Pituffik Space Base Thule Dormitory in Greenland provides the specifications, selections and warranty information for the interior finishes and furniture for this facility. This package is being developed to meet the furniture and finish requirements for this project.

A. Function: A relationship of all interior and exterior spaces has been developed to facilitate daily operations, enhance operational efficiencies, and provide customer satisfaction.

B. Cost Effectiveness: All finishes provided will reflect the best value in terms of aesthetic value and life-cycle costs. There will be consideration in appointing funds to appropriate locations. Areas that provide the most impact on the customers experience will be considered important locations.

C. Durability: Selection of quality materials will ensure that the facility will look fresh and clean for years to come.

D. Maintainability: Finishes will be selected to limit future maintenance requirements.

E. Design: The design objective of this facility is simple; people should feel comfortable and productive in their living and work environments.

F. Creativity: The project will rely on innovation and creativity in color and style.

Providing the best value is the goal for the functions of this facility and the personnel who will use it.

G. Flexibility: Where finishes are more imbedded into the building design, such as porcelain tile, a more neutral color scheme is appropriate. Finishes that can be updated easily, such as paint, allow for more vibrant colors to be used. This allows for future renovations with little cost impact.

H. Timelessness: The interior image of this building should stand the test of time and minimize becoming outdated. Materials and finishes that relate to a more timeless standard or that may be easily updated with minimal cost will be incorporated.

I. Sustainability: Creating a healthy building for its users and for our planet will be at the forefront of the design. Finishes and adhesives with low VOC’s will help maintain a healthy indoor environment. Natural or recycled/recyclable materials will be a part of the design where possible. Also, durable materials that do not need a lot of maintenance will aid in the sustainability effort by conserving resources and decreasing waste generation.

SECTION 2 – STRUCTURAL INTERIOR

DESIGN:

JACOBS / EWINGCOLE | PITUFFIK SPACE BASE GREENLAND REPAIR DORMITORY BUILDING 99 – RENOVATIONS © JACOBS | © EWINGCOLE 2024

2.1 Room Finish Schedule and Interior Material Finish Key

GENERAL FINISH NOTES

1. REFER TO CID PACKAGE FOR FINISH SAMPLES, WARRANTY, FINISH MATERIAL KEY AND CUT SHEET INFORMATION.

2. REFER TO CID PACKAGE FOR FURNITURE DIMENSIONS AND DETAILS ON FURNITURE ORDER FORMS.

3. REFER TO I-401 FOR LABELED ENLARGED FURNITURE PLANS.

4. REFER TO CID PACKAGE FOR INFORMATION ON TILE GROUT, CABINET LAMINATE AND COUNTERTOP SOLID SURFACE.

CODE ABBREVIATIONS

ACT ACOUSTICAL CEILING PANEL PLAM PLASTIC LAMINATE

B BASE PTF PORCELAIN TILE FLOOR

CPT CARPET PTB PORCELAIN TILE BASE

CP CEILING PAINT PTW PORCELAIN TILE WALL

EXP EXPOSED STRUCTURE P PAINT

GWB GYPSUM WALL BOARD SC SEALED CONCRETE

GFC GLASS FIBER CLOTH SS SOLID SURFACE

MAT RECESSED FLOOR MAT VFC VINYL FLOOR COVERING

MR-GWB MOISTURE-RESISTANT GYPSUM WALL BOARD

ROOM FINISH SCHEDULE

INTERIOR FINISH MATERIALS KEY

INTERIOR FINISH MATERIALS KEY - FURNITURE

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

File Path:

Plot Date:

M A

R K

D E

S C

R

IP

T

IO

N

P R

O J E

C T

N O

C:\Revit Local Files\20230410_A22_USACE_CENTRAL_rofsharick.rvt

5/30/2024 10:09:51 AM

I-001

IN

T

E R

IO

R

F

IN

IS

H

S C

H E

D U

L E

S

R E

P A

IR

D

O R

M

IT

O R

Y B

U

IL

D

IN

G

R

. O

FS

H

AR

IC

K

R

. O

FS

H

AR

IC

K

EC

C

9/

/2

CONCEPT PHASE

P

IT

U F

F

IK

S P

A C

E B

A S

E G

R E

E N

L A

N D

NOTE: ACT-1 IS PREFERRED WHEREVER POSSIBLE - IN ALL ROOMS AND PUBLIC SPACES.

BEDROOM CPT-1 B-1 / P-3 GFC-1 / P-1 / PTW-1 / PTW-2 ACT-1 -

BATHROOM PTF-1 PTB-1 GFC-1 / P-1 / PTW-1 / PTW-2 MR-GWB / GFC-1 / CP-2 SS-1 / PLAM-1

KITCHEN/DINING PTF-1 PTB-1 GFC-1 / P-1 / PTW-1 GWB / GFC-1 / CP-1 SS-1 / PLAM-1

LAUNDRY VFC-1 B-2 GFC-1 / P-1 GWB / GFC-1 / CP-1 SS-1 / PLAM-1

MULTI-PURPOSE ROOM CPT-1 B-1 / P-3 GFC-1 / P-1 ACT-1 / GWB / GFC-1 / CP-1 -

JANITOR VFC-1 B-2 GFC-1 / P-1 ACT-1 -

STORAGE/CLOSET VFC-1 B-2 GFC-1 / P-1 ACT-1 -

MECHANICAL SC-1 B-1 / P-5 GFC-1 / P-1 EXP / CP-1 -

ELECTRICAL SC-1 B-1 / P-5 GFC-1 / P-1 EXP / CP-1 -

CORRIDOR CPT-1 B-1 / P-3 GFC-1 / P-1 ACT-1 -

STAIR SC-1 SC-1 GFC-1 / P-1 GWB / GFC-1 / EXP / CP-1 -

VESTIBULE CPT-1 / MAT-1 B-1 / P-3 GFC-1 / P-1 GWB / GFC-1 / CP-1 -

ROOM TYPE FLOOR FINISH BASE FINISH WALL FINISH CEILING FINISH MILLWORK FINISH

SU-4 SEATING UPHOLSTERY PALLAS BALLAD AZURE USED ON SO-1

SU-3 SEATING UPHOLSTERY PALLAS STITCH OCEAN BLUE USED ON CHR-3

SU-2 SEATING UPHOLSTERY PALLAS ALEA SILVER USED ON CHR-2 & CHR-4

F U

R N

IT

U

R

E SU-1 SEATING UPHOLSTERY KI PARQUET NAUTICAL USED ON CHR-1

SS-1 SOLID SURFACE WILSONART - WHITE STONE 9208CS COUNTERTOPS

PLAM-1 PLASTIC LAMINATE WILSONART - FAWN CYPRESS 8208K-16 CABINETS; VERTICAL GRAINM

IS

C GT-1 GROUT BOSTIK

TRUCOLOR RAPIDCURE URETHANE

GROUT LUNAR H196 -

CP-2 CEILING PAINT - WET AREAS FLUGGER FLUTEX DEKSO 20 RAW WHITE -

CP-1 GENERAL CEILING PAINT FLUGGER FLUTEX PRO 5 RAW WHITE -

C E

IL

IN

G S

ACT-1 ACOUSTICAL CEILING TILE ARMSTRONG

#1772 DUNE - SQUARE LAYOUT

24" x 24" x 5/8" WHITE 15/16" GRID

GFC-2 GLASS FIBRE CLOTH - WET AREAS FLUGGER

GLASS WOVEN TISSUE MEDIUM

380 ADHESIVE MOISTURE-PROOF -

PRODUCT ID 44135

PRODUCT ID 23850

GFC-1 GLASS FIBRE CLOTH FLUGGER

GLASS WOVEN TISSUE MEDIUM

378 ADHESIVE ROLL-ON EXTRA -

PRODUCT ID 44135

PRODUCT ID 33448

PTW-2 PORCELAIN TILE WALL - ACCENT DALTILE VOLUME 1.0 DEGREES SILVER VL71 6" x 24" ON WALLS

PTW-1 PORCELAIN TILE WALL DALTILE VOLUME 1.0 SONIC WHITE VL75 6" x 24" ON WALLS

P-3 STAIR RAILING PAINT AND DOOR TRIM FLUGGER HIGH FINISH 50 GRAY -

P-2 WALL PAINT - WET AREAS FLUGGER FLUTEX DEKSO 20 RAW WHITE -

W A

L L S

P-1 GENERAL WALL PAINT FLUGGER FLUTEX PRO 5 RAW WHITE -

PTB-1 PORCELAIN TILE BASE DALTILE VOLUME 1.0 SONIC WHITE VL75 P-36C9TB

B-2 BASE TARKETT

INTEGRAL 2-IN-1 BASE COVE

FORMER & CAPPING WITH

STANDARD PLUS HOMOGENEOUS

SHEET FLOOR PUR SURFACE TREATMENT

B A

S E

S

B-1 BASE - MDF 14 x 65 MM WHITE PRIMED -

VFC-1 VINYL FLOOR COVERING TARKETT

STANDARD PLUS HOMOGENEOUS

SHEET FLOOR STONE GREY 0924 PUR SURFACE TREATMENT

SC-1 SEALED CONCRETE - - - -

MAT-1 RECESSED ENTRY MAT MATTER SURFACES

ARCHITECTURAL GRILLES-ADVANCE

TRACK

GRILL: ALUMINUM

CARPET: NEW YORK

COLLECTION - DARK GRAY -

PTF-1 PORCELAIN TILE FLOOR DALTILE VOLUME 1.0 SONIC WHITE VL75 12" x 24" ON FLOORS

F L O

O R

S

CPT-1 CARPET TILE TARKETT

APPLAUSE III 02803

24" X 24" SKYSCRAPER 28525 -

FINISH CODE FINISH MATERIAL MANUFACTURER STYLE COLOR COMMENTS

SECTION 2 – STRUCTURAL INTERIOR

DESIGN:

JACOBS / EWINGCOLE | PITUFFIK SPACE BASE GREENLAND REPAIR DORMITORY BUILDING 99 – RENOVATIONS © JACOBS | © EWINGCOLE 2024

2.2 Material Cutsheets

TechLine 877 276-7876 armstrongceilings.com/dune

Dune Tegular panels with Interlude® XL HRC 9/16" suspension system

KEY SELECTION ATTRIBUTES

Ł̃ DuneŽ panels are part of the Sustain® por˚folio, and meet the most stringent industry sustainability compliance standards today

Ł̃ Upgrade look at a modest price

Ł̃ Ceiling-2-CeilingŽ Post-consumer Recycled Content options: Items 17˛˝HRC, 17˛̇ HRC, 17˛ˆHRC, 17˛̌ HRC, 17˛˛HRC

(check armstrongceilings.com/greengenie)

Ł̃ Mold- and mildew-resistant surface

Ł̃ USDA-Certi˘ed Biobased Product Œ 99%

Ł̃ Durable Œ Scratch-resistant

Ł̃ Non-directional visual reduces scrap and installation time

Ł̃ Product can be recycled through the Armstrong Ceilings Recycling Program

Ł̃ 30-Year Limited System Warranty against visible sag (excludes items 1796 and 1798), mold and mildew

Ł̃ 10-Year replacement panel available for items 1772, 1773, 1774, 1776

DUNEŽ

Square Lay-in & Tegular ˘ne texture

DuneŽ Square Lay-in panels with Prelude® XL® 15/16" suspension system

Fine-textured panels are non-directional and durable with standard acoustical performance.

DETAILS (Other Suspension Systems compatible. Refer to listing on next page.)

�. DuneŽ Tegular

�. DuneŽ Square Lay-in with Prelude® 15/16" suspension system

˝. DuneŽ Tegular with Supra˘ne ® 9/16" suspension system

4. DuneŽ Tegular with Silhoue˚te® XL® 9/16" suspension system with 1/4" reveal

ˆ. DuneŽ Tegular with Interlude® XL® HRC �/�ˇ" suspension system1 2 3 4 5

COLOR

White

(WH)

CAD/Revit® drawings at:

armstrongceilings.com/cadrevit

ACT-1

M

IN

E R

A

L FIB

E R

� S tandard

TechLine 877 276-7876 armstrongceilings.com/dune armstrongceilings.

com/suspdwgs

Susp.

Dwg. Item No.

Dimensions (Inches)

UL Classified

Acoustics To ta l Ac ou st ic s1

Fi re

Pe rfo rm an ce

Li gh t R efl ec t

Bio- Block

Humi- Guard+

Ce rti fie d

Lo w

VO

Em is si on s

DURABILITY

Re cy cl ed

C on te nt

Re cy cl e

Pr og ra m

-Y r W ar ra nt y

An ti-

M ol d/ ild ew

Sa g

Re si st an t

Sc ra tc h

NRC + =

DUNE™

15/16" Square Lay-in

1 1772 24 × 24 × 5/8" 0.50 30 N/A Class A

0.81 Ł Ł Ł Ł Std Ł Ł

1850 24 × 24 × 5/8" 0.50 35 Ł

N/A Fire GuardŽ

0.81 Ł Ł Ł Ł Std Ł Ł

1773HRC

24 × 48 × 5/8" 0.50 30 N/A Class A

0.81 Ł Ł Ł Ł Std

Ł

Ł Ł

1851 24 × 48 × 5/8" 0.50 35 Ł

N/A Fire Guard

0.81 Ł Ł Ł Ł Std Ł Ł

1796 20 × 60 × 3/4" 0.50 35 Ł

N/A Class A

0.81 Ł Std Ł Ł Ł Ł 1-Yr

1798 30 × 30 × 3/4" 0.50 35 Ł

N/A Class A

0.81 Ł Std Ł Ł Ł Ł 1-Yr

3/4" or 5/8" Thick – 15/16" Square Lay-in

Made-to-Order Sizes

Width Length N/A N/A N/A Class A

0.81 Ł Std Ł Ł Std Ł 1-Yr

12" - 30" 18" - 72"

Red Numbers are Fire Guard items.

1 Total Acoustics ® ceiling panels have an ideal combination of sound absorption and sound blocking in one product.

DUNEŽ

Square Lay-in & Tegular ˘ne texture

VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance. $ $$$

SUSPENSION SYSTEMS

15/16"

Prelude® XL®

Prelude® XL® Fire Guard

Insulation Value R Factor Œ 1.6 (BTU units) R Factor Œ 0.28 (Wa˚ts units)

30-Year Performance Guarantee & Warranty When installed with Armstrong® Suspension System.

Details at armstrongceilings.com/warranty (Excludes items 1796, 1798, and large other size panels)

Weight; Square Feet/Carton 1772 Œ 0.94 lbs/SF; 64 SF/ctn 1773 Œ 0.88 lbs/SF; 64 SF/ctn 1796 Œ 1.33 lbs/SF; 67 SF/ctn 1798 Œ 1.14 lbs/SF; 50 SF/ctn 1850 Œ 1.19 lbs/SF; 48 SF/ctn 1851 Œ 1.22 lbs/SF; 64 SF/ctn

Minimum Order Quantity 1 carton

Metric Items Available 17 �̨M, 18ˆ�M, 17˛˝M, 18 �̂M, 17�ˇM, 17��M Œ Metric items are subject to extended lead times and minimum quantities. Contact your representative for more details.

PHYSICAL DATA

Material Wet-formed mineral ˘ber

Surface Finish Factory-applied latex paint

Fire Performance Class A: ASTM E�˙ and CAN/ULC S��� surface burning characteristics. Flame Spread Index of 25 or less. Smoke Developed Index of 50 or less (UL labeled).

Fire GuardŽ: A ˘re-resistive ceiling when used in applicable UL assemblies.

ASTM E1264 Classification Type III, Form 2, Pa˚tern C E Fire Class A

Humidity/Sag Resistance HumiGuard® Plus ceiling panels are recommended for areas subject to high humidity, up to, but not including, standing water and outdoor applications. Excludes large made-to-order panels.

Anti-Mold/Mildew Ceiling tiles with BioBlock® performance resist the growth of mold and mildew on the tile surface.

Acoustical Performance CAC testing conducted using Prelude ® suspension system.

VOC Emissions GREENGUARD Gold Certified Third-party certi˘ed compliant with California Department of Public Health CDPH/EHLB/Standard Method Version 1.2, 2017. This standard is the guide-line for low emissions in LEED®, WELL Building StandardŽ, Living Building Challenge® (LBC), CalGreen Title 24, ANSI/ASHRAE/USGBC/IES Standard 189; ANSI/GBI Green Building Assessment Protocol.

Primary (Embodied) Energy See all LCA information on our EPDs.

High Recycled Content Contains greater than 50% total recycled content.

Total recycled content based on product composition of post-consumer and pre-consumer (post-industrial) recycled content per FTC guidelines. HRC items contain 15% or greater post-consumer recycled ceilings.

MORE ITEMS

99%

GREENGUARD

Gold Certified

(details below) en er gy m an ag em en t re cy cl ab le ex te nd ed pr o d uc er re sp m at er ia l in gr ed ie nt po rt in g re c y co en t so u r ci ng o f ra w m at er ia ls lo w e m itt in g/ at er ia ls lig ht qu al ity bi ob as er ia ls re gi on er ia ls de si gn fo r fle xi bi lit y co ns tr uc tio n w as te m gm t

EP

D ac ou st ic s

LOCATION DEPENDENT

W E

LL

LB

Calculate sustainability with Green Genie™ armstrongceilings.com/greengenie

RECYCLED

CONTENT56%UP

T O

L E

D®

PRODUCT CERTIFIED

FOR LOW CHEMICAL

EMISSIONS

UL.COM/GG

UL 2818

TechLine / 1 877 276-7876 armstrongceilings.com/dune

BPCS-4351-123

M

IN

E R

A L

FI

B

E R

S ta nd ar d

LEED® is a registered trademark of the U.S. Green Building Council; Declare® and Living Building Challenge® (LBC) are trademarks of the International Living Future Institute®; WELL™ and WELL Building Standard are trademarks of the International WELL Building Institute; UL and UL Certified are trademarks uf UL LLC; all other trademarks used herein are the property of AWI Licensing LLC and/or its affiliates © 2023 AWI Licensing LLC armstrongceilings.

com/suspdwgs

Susp.

Dwg. Item No.

Dimensions (Inches)

UL Classified

Acoustics To ta l Ac ou st ic s1

Fi

Pe rfo rm an ce

Li gh t R efl ec t

Bio- Block

Humi- Guard+

Ce rti fie d

Lo w

VO

Em is si on s

DURABILITY

Re cy cl ed

C on te nt

Re cy e

Pr og ra m

-Y r W ar ra nt y

An ti-

M ol d/ ild ew

Sa

Re si st an t

Sc ra tc h

NRC + =

DUNE™

15/16" Angled Tegular

12 1774

1774HRC

24 × 24 × 5/8" 24 × 24 × 5/8"

0.50 35 Ł

N/A Class A

0.81 Ł Ł Ł Ł Std

Ł

Ł Ł

1853 24 × 24 × 5/8" 0.50 35 Ł

N/A Fire Guard

0.81 Ł Ł Ł Ł Std Ł Ł

1776HRC

24 × 48 × 5/8" 24 × 48 × 5/8"

0.50 35 Ł

N/A Class A

0.81 Ł Ł Ł Ł Std

Ł

Ł Ł

9/16" Beveled Tegular

1775HRC

24 × 24 × 5/8" 24 × 24 × 5/8"

0.50 35 Ł

N/A Class A

0.81 Ł Ł Ł Ł Std

Ł

Ł Ł

1852 24 × 24 × 5/8" 0.50 35 Ł

N/A Fire Guard

0.81 Ł Ł Ł Ł Std Ł Ł

1777HRC

24 × 48 × 5/8" 24 × 48 × 5/8"

0.50 35 Ł

N/A Class A

0.81 Ł Ł Ł Ł Std

Ł

Ł Ł

3/4" or 5/8" Thick – 15/16" & 9/16" Angled Tegular

Made-to-Order Sizes

Width Length N/A N/A N/A Class A

0.81 Ł Std Ł Ł Std Ł 1-Yr

12" - 30" 18" - 72"

Red Numbers are Fire Guard items.

1 Total Acoustics ® ceiling panels have an ideal combination of sound absorption and sound blocking in one product.

DUNEŽ

Square Lay-in & Tegular ˘ne texture

VISUAL SELECTION PERFORMANCE SELECTION Dots represent high level of performance. $ $$$

PHYSICAL DATA

Material Wet-formed mineral ˘ber

Surface Finish Factory-applied latex paint

Fire Performance Class A: ASTM E�˙ and CAN/ULC S��� surface burning characteristics. Flame Spread Index of 25 or less. Smoke Developed Index of 50 or less (UL labeled).

Fire GuardŽ: A ˘re-resistive ceiling when used in applicable UL assemblies (Class A)

ASTM E1264 Classification Type III, Form 2, Pa˚tern C E Fire Class A

Humidity/Sag Resistance HumiGuard® Plus ceiling panels are recommended for areas subject to high humidity, up to, but not including, standing water and outdoor applications. Excludes large made-to-order panels.

Anti-Mold/Mildew Ceiling tiles with BioBlock® performance resist the growth of mold and mildew on the tile surface.

Insulation Value R Factor Œ 1.6 (BTU units) R Factor Œ 0.28 (Wa˚ts units)

30-Year Performance Guarantee & Warranty When installed with Armstrong® Suspension System.

Details at armstrongceilings.com/warranty

Weight; Square Feet/Carton 1774, 17˛̇ HRC, 1775, 17˛ˆHRC Œ 0.75 lbs/SF; 64 SF/ctn 1776, 17˛̌ HRC, 1777, 17˛˛HRC Œ 0.75 lbs/SF; 64 SF/ctn 1852, 1853 Œ 1.20 lbs/SF; 48 SF/ctn

Minimum Order Quantity 1 carton

Metric Items Available 17˛ˆM, 17˛˛M Œ Metric items are subject to extended lead times and minimum quantities.

Contact your representative for more details.

Acoustical Performance CAC testing conducted using Prelude ® suspension system.

VOC Emissions GREENGUARD Gold Certified Third-party certi˘ed compliant with California Department of Public Health CDPH/EHLB/Standard Method Version 1.2, 2017. This standard is the guideline for low emissions in LEED®, WELL Building StandardŽ, Living Building Challenge® (LBC), CalGreen Title 24, ANSI/ASHRAE/USGBC/IES Standard 189; ANSI/GBI Green Building Assessment Protocol.

Primary (Embodied) Energy See all LCA information on our EPDs.

High Recycled Content Contains greater than 50% total recycled content.

Total recycled content based on product composition of post-consumer and pre-consumer (post-industrial) recycled content per FTC guidelines. HRC items contain 15% or greater post-consumer recycled ceilings.

SUSPENSION SYSTEMS

15/16" 9/16"

Prelude®

Prelude® XL® Fire Guard

Silhoue˚te® 1/4" Reveal

Silhoue˚te 1/8" Reveal

Supra˘ne ®

Supra˘ne ® XL® Fire GuardŽ

Interlude®

99%

GREENGUARD

Gold Certified

(details below) en er gy an ag em en t re cy cl ab le ex te nd pr o d uc er re sp m at er ia l in gr ed ie po rt in g re c y co en t so u r ci ng o f ra w m at er ia ls lo w e m itt g/ er ia ls lig ht qu ity bi ob as er ia ls re gi on er ia ls de si gn fo r fle xi bi lit y co ns tr uc tio n w as te m gm t

EP

D ac ou st ic s

LOCATION DEPENDENT

W E

LL

LB

Calculate sustainability with Green Genie™ armstrongceilings.com/greengenie

RECYCLED

CONTENT56%UP

T O

L

D®

PRODUCT CERTIFIED

FOR LOW CHEMICAL

EMISSIONS

UL.COM/GG

UL 2818

PAD8 PAD10

7,5

7,5

PVC profile providing a neat cove allowing floor coverings to be dressed up to the wall to form a skirting.

DESCRIPTION

Key features:

2-in-1 system: both cove former and capping integrated solution.

Floor covering supported at a weak point, forming round shape angle.

Protection of the top of the floor covering.

Easy cleaning and maintenance.

Compatible flooring:

Homogeneous & heterogeneous vinyls in rolls (both compact & acoustic version).

Main segments of application:

TECHNICAL INFORMATION

ARTICLE CODE

INSTALLATION

Use an acrylic contact adhesive.

Cut the profile to the desired length.

Spread adhesive on the backside of the capping with an appropriate brush.

CLEANING & MAINTENANCE

For regular cleaning, use standard neutral detergents (ph7) and a dedicated tool specific for capping cleaning.

EAN CodeEAN Code SAP CodeSAP Code

PAD8 PAD10

Light Grey

RAL: 7500

NCS: S 3000 N

White

RAL: 9003

NCS: S 0500 N

3423128397536

3423128397543

3423128397567

3423128397574

1437 0001

1437 002

1438 001

1438 002

Product

Packaging

Size (mm)

Unit weight (g)

Pieces per box Box size (cm)

Box weight (kg)

Pallet size (m)

Boxes per pallet

Min. order

2000 length x 20 lower width x 5 upper width x 80 height 2000 length x 20 lower width x 5 upper width x 100 height

20 (40lm) PAD8 1.15 x 0.11 x 0.13 PAD10 2.13 x 0.11 x 0.13

PAD8 14

PAD10 15

PAD 8 2 x 0.8 x 0.8 PAD10 2 x 0.8 x 0.8

PAD8 380

PAD10 420

1 box

Technical Datasheet

PVC cove formers & cappings 2 in 1 - cove former & capping - PAD 8/10

SKIRTINGS & COVING

B-2

Applause III #02803 Product Specification

Face Construction Imperial Metric Construction Level Loop Face Weight 18 oz/sq yd 610.2 g/sq m Gauge 1/13 50.4 rows/10 cm Stitches per Inch 8.2 32.3 pu/10 cm Tuft Density 104.96 tufts/sq in 16.3 tufts/sq cm Pile Height Average 0.117 inch 3.0 mm Pile Thickness 0.087 inch 2.2 mm Density Factor 7,448 oz/cu yd 275.6 kg/cu m Fiber System Dynex SD® / Dynex® Nylon Dye Method 50% Solution Dyed / 50% Yarn Dyed Fluorine-Free Soil Protection Eco-Ensure 9.4 Kilotex Primary Tufting Substrate Synthetic Non-Woven Pattern Match Not Required

Third Party Environmental Certifications Product

Overall SCS Certified Certified ethos® Modular with Omnicoat Technology® 47-75% Certified Powerbond® Cushion 7-33% Certified Flex-Aire Modular® Cushion 21-41% Certified Powerbond® Medfloor® 7-33% *Minimum recycled content certified by Scientific Certification Sytems (SCS) and varies by product style.

**Cradle to Cradle Certified is a certification mark licensed by the Cradle to Cradle Products Innovation Institute

Product Testing/Information Antimicrobial Chemicals No antimicrobials (EPA Registered pesticides) added to product (ASTM E2471-05) Electrostatic Propensity 2.2 kV (AATCC 134); Permanent Conductive Fiber Surface Flammability Passes CPSC FF 1-70 (ASTM D-2859) Flooring Radiant Panel Class 1 (mean average CRF: 0.45 w/sq cm or higher) (ASTM E-648) Smoke Generation Less than 450 (ASTM E-662) Colorfastness to Light > 4 after 60 hours (AATCC 16E) Soil Protection Application Rate: 2% of Face Weight

Installation Methods Peel and Stick RS Adhesive System - Full Coverage Peel & Stick Wet Spread Backing specific Tarkett Adhesives Installation Method 24" x 24" Monolithic; 18" x 36" Vertical Ashlar, Herringbone

Product Notes

1. Specifications are subject to nominal manufacturing variances. Material supply and/or manufacturing processes may necessitate changes without notice. Colors may vary slightly from dye lot to dye lot.

2. U.S. Patent numbers: 4,849,267; 6,406,574, US 9,988,760 B2

3. Chair pads are recommended for optimum textural performance. Absent the use of chair pads, more intensive maintenance will be required for areas in direct contact with chair caster traffic, and some degree of appearance change is to be expected.

Tarkett North America Technical Services Department 1735 Cleveland Hwy Dalton, GA 30721

800.248.2878 Fax 706.259.2621

info@tarkettna.com www.tarkettna.com © 2021 Tarkett USA Inc. 12/2021

Certified™ v3.1** 28% 7% Gold 4% Gold 7%

Silver

Recycled Content* Postconsumer

Platinum

NSF 140 Cradle to Cradle

CPT-1

IMPERIAL TEST METHOD

Warranty: Lifetime limited warranty against excessive surface wear, static, delamination, edge ravel, zippering, & backing resiliency loss.

ethos® Modular with Omnicoat Technology® Total Minimum Recycled Content 58.1% SCS Certified total 47-75% Pre-Consumer 23.6% SCS Certified Postconsumer 34.5% SCS Certified Third Party Certification NSF-140 Platinum SCS Certified Cradle to Cradle Certification Silver (Certification #1904) Cradle to Cradle Certified™ v3.1 Product Size 24" x 24" Tile (18" x 36" also available) Secondary Backing 50% Recycled Content Intermediate Layer Fiberglass Reinforced Sealant Product Construction No Delamination per ASTM D-3936 Secondary Backing Density 65.0 lbs/cu ft 1041 kg/cu m Secondary Backing Thickness 0.050 inch 1.3 mm Total Weight 95.9 oz/sq yd +/-5% 3250.7 g/sq m CRI Green Label Plus Certification GLP8320 Flex-Aire Modular® Cushion Total Minimum Recycled Content 25.2% SCS Certified total 21-41% Pre-Consumer 19.5% SCS Certified Postconsumer 5.7% SCS Certified Third Party Certification NSF-140 Gold SCS Certified Product Size 24" x 24" Tile (18" x 36" also available) Secondary Backing Fiberglass Reinforced Composite Closed Cell Cushion Intermediate Layer Fiberglass Reinforced Sealant Product Construction No Delamination per ASTM D-3936 Cushion Weight 35.5 oz/sq yd 1203 g/sq m ASTM D1667 Cushion Density 18.5 lbs/cu ft 296 kg/cu m ASTM D1667 Cushion Thickness 0.156 inch 4.0 mm ASTM D1667 Total Weight with RS / Non-RS 117.1 115.7 oz/sq yd +/-5% 3971 3924 g/sq m Compression Set Max. 10% ASTM D1667 Compression Deflection 5 Min. 25 max lbs/sq inch @ 25% 352 1758 g/sq cm ASTM D1667 CRI Green Label Plus Certification GLP6558 Powerbond® Cushion Total Minimum Recycled Content 8.5% Pre-Consumer 0.0% Postconsumer 8.5% Third Party Certification NSF-140 Gold Product Size 6 ft.

Cushion Closed Cell Cushion Heterogeneous Construction No Delamination per ASTM D-3936 Cushion Weight 35.5 oz/sq yd 1203 g/sq m ASTM D1667 Cushion Density 18.5 lbs/cu ft 296 kg/cu m ASTM D1667 Cushion Thickness 0.156 inch 4.0 mm ASTM D1667 Total Weight with RS / Non-RS 79.0 76.7 oz/sq yd +/-5% 2679 2601 g/sq m Compression Set Max. 10% ASTM D1667 Compression Deflection 7 Min. 25 max lbs/sq inch @ 25% 492 1758 g/sq cm ASTM D1667 CRI Green Label Plus Certification GLP9744 Powerbond Medfloor® Total Minimum Recycled Content 9.0% Pre-Consumer 0.0% Postconsumer 9.0% Product Size 6 ft.

Cushion Medfloor Heterogeneous Construction No Delamination per ASTM D-3936 Cushion Weight 37 oz/sq yd 1254 g/sq m ASTM D1667 Cushion Density 30 lbs/cu ft 481 kg/cu m ASTM D1667 Cushion Thickness 0.085 inch 2.2 mm ASTM D1667 Total Weight 78.2 oz/sq yd +/-5% 2652 g/sq m Compression Set Max. 10% ASTM D1667 Compression Deflection 29 lbs/sq inch @ 25% 2039 g/sq cm ASTM D1667 CRI Green Label Plus Certification GLP9744

800.248.2878 www.tarkettna.com © 2021 Tarkett USA Inc. 12/2021

METRIC

' ' ' '()*+ ,-)./012 34-5+1 ,)6+-7)8.9:;<7-=.:04-5+1 >55?4/2+:@@@

>55?4/2+:@@@

ABCCDEFFDGHFHIJEKLDMNOP

QRSTRDBUVWXTB

YZ[\>]̂:_:̂@̀â b cdFCDMefP g RHFFDMeOP h i '

,[Zjk3]:ja]>@l̂ m k̂̂ ]>@n>o@l@]p m

,̂a3@Y@3>]@Zn̂ m q

UXXDWRQSrscB

>55?4/2+:@@@

NODSTBtuvB w x

>,,l>k̂a:@@@ yz{y| ]>,â][p z{}y}

>,,l>k̂a:@@@ yz{y| â>~aaj z{}y�

>,,l>k̂a:@@@ yz{y|:�k@n3a z{}y{

>,,l>k̂a:@@@ yz{y| \aj@]a[[>na>n z{}�|

>,,l>k̂a:@@@ yz{y| \an>�a[@a z{}��

>,,l>k̂a:@@@ yz{y| Y@[a~Z[�̂ z{}�}

>,,l>k̂a:@@@ yz{y|:\>[@na z{}��

>,,l>k̂a:@@@ yz{y|:l>,@̂ z{}�{

>,,l>k̂a:@@@ yz{y| 3>[n@�>l z{}zy

./01'22'1.3/ 4

536/23'50787.9':;0 4

<+=>*+>-?)76@AA7B@*) <+=>*+>-?)70?@-,C)AA79@>@D)E)>?

F G

F G

HIIJKLMNOPQR

'SSA@T*)7...

UVJNWRXYZR

'[[2'\0;7...

1'[;01ab _̂c]c

'[[2'\0;7...

0;'6;;5 _̂c]d

'[[2'\0;7...

]̂_]̀7e\./f;

_̂c]_

'[[2'\0;7...

9;5.1;aa'/;'/ _̂cg̀

'[[2'\0;7...

9;/':;a.;

_̂cgh

'[[2'\0;7...

i.a;63aj0 _̂cgc

'[[2'\0;7...

]̂_]̀79'a./;

_̂cgd

'[[2'\0;7...

]̂_]̀72'[.0 _̂cg_

'[[2'\0;7...

f'a/.k'2 _̂ĉ]

+,-./0123-1245+1 6

0/21372/03.8291.. 6

-.8:35;3./,+<

=>?@ABCADEAFGHG>IGABCJKDGLAKMEBDAEBFADKFNGDDACFEJBHDLAK@JA@GOLP

QEEN>GARES>HT UG?KS VGFWLAEXAYLG QKFGGFL ZMEBDAVKFNGDD

[@DGFA[WK>S \

ZUUAR]̂ _YQV=

8̀ àbcde3555 fgA_[=hij=

8kkl8,-13555 mnomp .8k1-.2:

noqmq

8kkl8,-13555 mnomp -18r11s noqmt

8kkl8,-13555 mnomp3u,5;+1 noqmo

8kkl8,-13555 mnomp 01s5.1228;18;

noqvp

8kkl8,-13555 mnomp 01;8w1251 noqvx

8kkl8,-13555 mnomp 7521r/29-noqvq

8kkl8,-13555 mnomp30825;1 noqvt

8kkl8,-13555 mnomp3l8k5-noqvo

8kkl8,-13555 mnomp +82;548l noqnm

Product Data Sheet

Glass woven Flügger felt and tissue for installation on walls and ceilings. Provides an aesthetic look with or without pattern depending on design chosen.

Enhances the surface and counteracts cracking. Finished with paint in desired gloss and colour.

Properties Uncoated glass tissue for installation on walls and ceilings. Weight 125 g/m². Easy installation. Unsaturated surface that requires primer. Available in fine, medium and coarse structure.

Easy installation

Enhances surface

Counteracts cracking

Use

Living rooms/common rooms, hallways and entrance areas, offices, kitchens, toilets, commercial premises, clinics and shops. Not suitable for surfaces requiring wet room water- and damp-proofing. Concrete, light concrete, plaster, plasterboard and gypsum fibre board.

Substrate

Must be clean, dry, firm and suitable for surface treatment.

Treatment

Remove loose material and paint by cleaning and sanding. Remove existing wallpaper. Remove dirt, grime, grease and chalking materials by cleaning. Water-soluble discolouration, nicotine and soot are cleaned and treated with blocking primer. Hard, smooth substrates should be sanded to a matt finish and painted with primer. Smooth out cracks, unevenness and holes with filler. Paint absorbent and porous substrates with primer.

Application

The glass tissue panels are cut into full lengths corresponding to the surface to be covered, + 10 cm for trimming. Apply glue evenly to the contact surface, 1-2 panels at a time. Install the panels edge to edge. Remove air bubbles using a wallpaper spatula. Cut away the excess glass felt against adjacent surfaces. Wipe off excess adhesive with a sponge and lukewarm water. Always test adhesion and result before hanging

Expected result

Uniform, smooth surface. The surface may have some unevenness. Apply primer when the wall covering surface is dry.

Intermediate sanding if necessary after the primer is dry. Finish treat with paint in desired gloss and colour. Best results reached after two coats. Avoid placing loads on the surface before the treatment is fully cured.

Usefull Information

Recommended adhesive: Flügger Adhesive 377 Easy

GFC-1 & GFC-2

Produkttype Felt and Tissue

Cleaning of tools etc. Water

Working temperature Min. +10°C

Please note!

Ensure good ventilation during and after hanging.

Supplemental Text

Remove as much adhesive as possible from brushes before washing them in water. Do not pour residue/remains of paint down the drain; take it to your local recycling centre. Minimise your paint waste by calculating how much paint you need in advance. Store leftover paint properly so the remains can be reused, which minimises the environmental impact.

Technical Data

Current TDS Version

February 2021

Replaces TDS Version

December 2021

378 Adhesive Roll-on Extra Flügger Adhesive is adhesive for hanging wall coverings.

Product properties Ready-mixed, transparent, extra-reinforced adhesive. For hanging a wall covering where the adhesive is applied to the wall.

Adhesive, wall covering

Extra strong

Can be sprayed on

Labelling

Product use

Indoors in a dry room for hanging a wall covering 130-250 g/m2, e.g. glass felt, fibre felt, structural felt and glass fabric.

On concrete, lightweight concrete, plaster, gypsum board, fibreglass, wood-fibre boards, veneer sheets, chipboard and sandblasted substrates.

Substrate

Must be clean, dry, firm and suitable for substrate treatment.

Treatment

Remove loose material and paint by cleaning and sanding.

Remove dirt, grime, grease and chalking materials by cleaning with Fluren 37.

Water-soluble discolouration, nicotine and soot can be cleaned with Fluren 49 and treated with Stop Primer.

Hard, smooth substrates should be sanded to a matt finish and primed as required using Fix Primer.

Cracks, unevenness and holes must be filled.

Absorbent and porous substrates can be primed with Sealer.

Untreated, painted and wallpapered substrates can be primed with Combi Primer.

Product Type [14]

Density (kgs/l) 1.05

Solids Weight % 25

Solids Vol. % 21

Nominal spreading rate (m²/ltr.) 5

Min. working temp. during application and drying/curing Min. +15°C

Humidity Max. humidity 80 % RH.

Dilution Do not dilute

Cleaning of Tools etc. Water

Application

Apply on wall using brush or roller.

Adjust layer thickness to substrate and wall covering.

Apply uniformly wet on wet and finish by brushing/rolling in the same direction.

Allow the adhesive to dry briefly before hanging the wall covering.

Differences in layer thickness or uneven structure can result in a non-uniform substrate.

Insufficient layer thickness results in the risk of blistering and inadequate adhesion.

Excess layer thickness results in the risk of cracking and visible stains.

Adhesive applied to the front of the wallpaper may cause visible stains.

Cold/heat can affect the viscosity of the material.

Condensation must be prevented during drying/curing.

Cold and increased atmospheric humidity extends drying time and full curing.

Increased temperature and low atmospheric humidity reduce drying time and full curing.

Always perform a test treatment for a check and acceptance of adhesion and result.

Expected result

Uniform and well fastened to substrate.

Does not prevent penetration of knots and water-soluble dyes, water stains and nicotine.

Can be painted over when wall covering and adhesive are completely dry.

Exercise care in loading the substrate until the adhesive is fully cured.

Please note!

Ensure good ventilation during and after hanging.

Environmental information

Remove as much paint as possible from tools before cleaning. Bring remains of fluent paint to the local recycling centre. Minimize your paint waste by pre-estimating how much paint you need. Keep the leftover paint for future use so you can effectively reduce the environmental impact.

Storage: Cool, frost free and tightly closed

Supplementary Info

For this product there is issued an: Environmental Product Declaration

Technical Data https://www.environdec.com/library/epd3210

Current TDS Version

October 2023

Replaces TDS Version

June 2022

380 Adhesive Moisture-proof Flügger Adhesive is adhesive for hanging wall coverings.

Product properties Ready-mixed, transparent, moisture-resistant adhesive. For hanging a wall covering where the adhesive is applied to the wall.

Adhesive, wall covering

Moisture resistant

Can be sprayed on

Product use

Indoors in a room exposed to varying humidity for hanging a wall covering e.g. glass felt, fibre felt, structural felt and glass fabric.

On concrete, lightweight concrete, plaster and substrates spackled with moisture-resistant sand putty.

Substrate

Must be clean, dry, firm and suitable for substrate treatment.

Treatment

Remove loose material and paint by cleaning and sanding.

Remove dirt, grime, grease and chalking materials by cleaning with Fluren 37.

Water-soluble discolouration, nicotine and soot can be cleaned with Fluren 49 and treated with Stop Primer.

Hard, smooth substrates should be sanded to a matt finish and primed as required using Fix Primer.

Cracks, unevenness and holes must be filled.

Absorbent and porous substrates can be primed with Sealer.

Application

Apply on wall using brush or roller.

Adjust layer thickness to substrate and wall covering.

Apply uniformly wet on wet and finish by brushing/rolling in the same direction.

Allow the adhesive to dry briefly before hanging the wall covering.

Differences in layer thickness or uneven structure can result in a non-uniform substrate.

Insufficient layer thickness results in the risk of blistering and inadequate adhesion.

Excess layer thickness results in the risk of cracking and visible stains.

Adhesive applied to the front of the wallpaper may cause visible stains.

Cold/heat can affect the viscosity of the material.

Condensation must be prevented during drying/curing.

Cold and increased atmospheric humidity extends drying time and full curing.

Increased temperature and low atmospheric humidity reduce drying time and full curing.

Always perform a test treatment for a check and acceptance of adhesion and result.

Expected result

Uniform and well fastened to substrate.

Does not prevent penetration of knots and water-soluble dyes, water stains and nicotine.

Can be painted over when wall covering and adhesive are completely dry.

Exercise care in loading the substrate until the adhesive is fully cured.

Density (kgs/l) 1.05

Solids Weight % 31

Solids Vol. % 27

Nominal spreading rate (m²/ltr.) 5

Min. working temp. during application and drying/curing Min. +15°C

Humidity Max. humidity 80 % RH.

Dilution Do not dilute

Cleaning of Tools etc. Water

Please note!

Ensure good ventilation during and after hanging.

Not suitable for substrates where waterproof and steam-proof wet room protection is required.

Environmental information

Remove as much paint as possible from tools before cleaning. Bring remains of fluent paint to the local recycling centre.

Minimize your paint waste by pre-estimating how much paint you need. Keep the leftover paint for future use so you can effectively reduce the environmental impact.

Storage: Cool, frost free and tightly closed

Supplementary Info

Registered in the Nordic Ecolabelling Building Products Database for products which can be used in buildings with the Swan label.

Technical Data

Current TDS Version

February 2023

Replaces TDS Version

May 2022

TruColor®

RapidCure™

PREMIUM, PRE-MIXED, URETHANE GROUT

This supersedes and replaces in its entirety all previously published versions of this document.

T172 (Last revised on 010522)

DESCRIPTION

Bostik TruColor® RapidCure™ Premium, Pre-Mixed, Urethane Grout is a patented, water-based grout offering the ultimate in color accuracy, water resistance, and stain and crack protection. This breakthrough formulation installs up to 50% faster than traditional grouts and never needs to be sealed. Its perfect balance of flexibility and toughness enables it to exhibit unmatched performance. Unlike other grouts that contain loose color pigments, which can cause staining or be washed away during the installation process, TruColor® RapidCure™ quartz aggregate is color coated to ensure perfect color consistency every time you install. TruColor® RapidCure™ contains Bostik’s Blockade® antimicrobial protection, which inhibits the growth of bacteria, mold, or mildew on the surface of the dried grout and enables it to resist stains caused by mold. TruColor® RapidCure™ is approved for intermittent water exposure after only 3 days of cure and full-water submersion after 7 days of cure (see Typical Working Properties chart for details).

TruColor® RapidCure™ offers HXD™ Technology. HXD™ Technology enables only Bostik to offer the highest performance resin system of any premixed grout available. The resin system is the most important factor in grout performance. This breakthrough in polymer chemistry enables Bostik premium, pre-mixed grouts to offer unmatched toughness and water and stain resistance. Bostik HXD™ Technology contains an exceptionally high concentration of cross-linking molecules. This results in a larger, more unified polymer structure, or macro-molecule, which is more durable and resistant to penetration and staining from fluids. These superior characteristics provide unmatched performance in wet environments, which is further enhanced by proprietary additives that repel stains like no other pre-mixed grout.

TruColor® RapidCure™ is designed to have the perfect balance of physical properties in order to provide flexibility, strength, and adhesion, making urethane grouts an excellent choice for a wide variety of applications. TruColor® RapidCure™ contains a built-in urethane sealer technology, so it never needs to be sealed for the life of the installation and it also installs up to 50% faster than traditional grouts.

PRODUCT BENEFITS

• Premixed for fast, easy installation

• 3-day intermittent water exposure

• Submerged applications

• No powdered pigment additives*

• No color fading, streaking, or shading – even when wet!

• Does not contribute to efflorescence

• No sealing required ever!

• Chemical and stain resistant

• Re-usable (when stored properly in original container)

• UV stable – colors will not yellow, darken, or fade

• Easy water cleanup

• Non-sag formula ideal for vertical surfaces

• May contribute to USGBC LEED® Credits: MR 4.1 & 4.2 (Recycled

Content) and EQ 4.1 (Low-Emitting Materials)

* White contains some loose pigment

KEY FEATURES

– Consistent color every time

– No sealing required ever

– 3-day water exposure

TYPICAL PHYSICAL PROPERTIES

Description Results Water Cleanability (per ANSI 118.3) Pass

Density 14.8 lbs/gal

Vertical Joint Sag (per ANSI 118.3) Pass

Installation Temperature Range 40°F - 100°F (4°C - 38°C)

Shelf Life 3 years (in original unopened container)

Compressive Strength >3,500 psi*

Tensile Strength 510 psi

Recycled Content 8% pre-consumer recycled glass

* Test results were performed in an actual grout joint.

GT-1

WHILE SPREADING GROUT

• Grout small areas at a time.

Typically grout a 2-to-10 square-foot area (an arm’s length) or an area you can comfortably grout in 2 to 3 minutes. It is more a matter of time spent spreading grout than distance covered. Spreading too far without cleaning within two to three minutes will allow the grout to begin to cure on the surface of the tile and create haze issues. Work grout back and forth along the joint holding the float at a 45 degree angle to the face of the tile ensuring grout joints are completely packed. Ensure you have enough product on the surface of the tile while grouting to ensure you can easily move it around and pack the joints. Then hold the float at a 90 degree angle to the face of the tile and moving the trowel at a 45 degree angle to the line of the grout joint remove the excess grout with the float. This should remove 95% of the grout from the tile surface. NOTE: For best results, do not grout a large area, and make sure to clean as you go.

INITIAL CLEANUP

We recommend using a sponge with a blue microfiber on one side and two rinse buckets as follows:

• Double-rinse your sponge before each cleaning by dipping the sponge into the first bucket of water and then the second bucket of water. Squeeze sponge after rinsing in each bucket.

• Using the yellow side of the sponge, lightly work the sponge in a circular motion to loosen grout residue on the surface of the tile and tool and form the grout joints. Now dip the sponge in the second bucket of water. Using the blue side of the sponge, hold the sponge flat on the surface of the tile and wipe off excess grout residue at a 45 degree angle to the grout joints.

• Repeat this process once and then move on to the next grouting area. Remember not to spread an area larger than you can clean within 2 to 3 minutes.

DIRECTIONS FOR USE

Read and understand this technical data sheet and associated material safety data sheet completely before beginning. Always use protective clothing (gloves and eye protection) when working with grout. When installing tile, follow applicable ANSI, TCNA, and NTCA installation standards.

MIXING

DO NOT add any water, liquid, or other material to TruColor® RapidCure™. This will cause grout failure and void all warranties.

A translucent, milky liquid may be present on the surface of the grout upon opening the container. This is from normal settling during shipment. Mix grout in its pail with a margin trowel to bring grout to a uniform mixture. This mixing process should be approximately one minute. Use of a drill mixer is not recommended as it will introduce excessive air into the product and cause grout sagging on vertical applications, a reduction of color uniformity, and/or other performance issues such as pinholes. Continue to remix grout with margin trowel throughout the grouting process to ensure proper resin dispersion is maintained.

INSTALLATION

PRIOR TO GROUTING FULL INSTALLATION, APPLY TO A TEST AREA

TO BECOME FAMILIAR WITH APPLICATION AND TO ENSURE

PRODUCT SATISFACTION.

PREPARATION PRIOR TO APPLYING GROUT

• Ensure tile is firmly set and mortar is completely dry. NOTE:

When waterproofing, ensure waterproofing products are installed over the mud bed (not under). Wait at least 24 hours after setting tile before grouting with TruColor® RapidCure™.

Always follow tile manufacturer’s instructions before grouting.

• Remove all spacers, water, debris, and adhesive from tile joints.

Make sure the tile and the grout joints are clean and free of any contaminants that may inhibit the bond. For best results, the surface of tile should be at room temperature (70°F/21°C to 75°F/24°C). Urethane materials are affected by temperature and humidity variations. Cool temperatures and/or high humidity will slow cure time.

• To facilitate cleaning it is helpful to pre-seal porous or matte-finished surfaces (including unglazed porcelain, matte-finished glazed tile, and matte glass) with a water-based sealer (natural stone) or grout release (tile), including sides of natural stone The textured surfaces of these tiles allow the grout to settle into the textured surfaces during application making it more difficult to easily clean. For glass, metal, marble, stone, and other soft tiles, prepare a mockup and test the grout to ensure compatibility and that the grout may be installed without scratching the tile.

• Prior to re-grouting existing grout joints, completely remove all of the old grout and any surface contaminants. Rinse any residual material out of grout joints, then allow joints to completely dry before re-grouting.

APPLICATION OF GROUT

• Lightly dampen a sponge with clean water and apply to the top of the tile in a 2-to-10 square-foot area (an arm’s length). Wet tile enough to dampen while ensuring water is not pooling in grout joints. INSTALLATION TIP: Add 1 tablespoon of Dawn® dishwashing liquid per gallon of water and use to pre-wet tile to act as a grout release on matte-finished tile surfaces. NOTE: Do not use Dawn® dishwashing liquid in water used to clean up grout after application.

TYPICAL WORKING PROPERTIES

Description Time

Working Time 3 hours

Tack-Free Time 8 hours

Ready for Light Foot Traffic 24 hours

Ready for Heavy Foot Traffic 3 days

Stain Resistant (Food, Beverages, etc.) 3 days

Cure Time Before Intermittent Water Exposure (>70°F/21°C and <50% RH) 3 days

Cure time before use in submerged installations** 7 days ** Contact Bostik Tecnical Services to determine suitability for grouting any tile or stone that is to be submerged.

CHEMICAL RESISTANCE PROPERTIES (PER ASTM C267)

Chemical Resistance Typically Found In Results Acetic Acid (3%) Vinegar Pass

Ammonium Chloride Shampoo Pass

Citric Acid Solution (100 g/L) Household Cleaners Pass

Lactic Acid Milk Pass

Phosphoric Acid (10%) Household Cleaners Pass

Sulfamic Acid (10%) Cleaning Agents Pass

Sodium Hypochlorite (1:1) 3%

Bleach, Household Chemicals, Disinfectants Pass

Hydrochloric Acid (10%) Muriatic Acid Pass Results shown are typical and reflect test procedures used by the Tile Council of North America (TCNA).

RESIDUAL HAZE

If additional haze removal is necessary, Bostik Blaze™ Urethane Grout Haze Cleaner or Texspar Plus™ may be used. Make sure the grout is sufficiently cured to withstand light finger pressure without losing form. The approximate waiting time before additional cleaning is 3 hours in low humidity/warm temperature (<50% RH and >70°F/21°C) environments and 6 hours in high humidity/cool temperature (>50% RH and <70°F/21°C) environments. Spray Blaze™ on a nylon cleaning pad (such as a 3M® Doodlebug™) designed for delicate surfaces. Rub the cleaning pad lightly over the urethane haze on the tile being careful not to disturb the grout joints.

Excessive haze may require direct spray on surface, more dwell time or repeated cleaning. Do not flood surface with cleaner. Allow Blaze™ to rest on the tile/stone surface for at least 60 seconds to ensure sufficient penetration. Use a damp sponge and clean water to remove film and cleaner.

Finish by drying the tile surface with a clean towel or cloth. If the product has remained on the floor an extended period of time prior to cleaning or excessive residual product was not removed by Blaze™ use Texspar Plus™. See technical data sheet for use details.

Contact Bostik Technical Service if a persistent haze exists.

• Change the first bucket of rinse water approximately every 50 to 100 square feet or when the second bucket of rinse water no longer appears clean or clear. This avoids re-depositing the clear urethane binder back on the surface of the tile.

• There is no need to change both buckets of rinse water as you simply move the second bucket into the first bucket position and place the fresh bucket of rinse water in the second bucket position. This saves time and water! Check your work as you clean. Repair any low spots with additional grout. DO NOT over wash grout joints. INSTALLATION TIP: If working alone, only grout as far as you can reach (arm’s length) before cleaning. If working as a team, one person should grout, while the other(s) are cleaning immediately (no more than 2 to 3 minutes) behind the first person.

• Squeeze as much water out of sponge as possible before placing on tile.

• Place sponge flat on tile surface and use light pressure to ensure a full, flush grout joint. Use light pressure and keep sponge flat on tile surface. Do not bend sponge as this pulls grout from the joint.

AFTER SPREADING GROUT

If this process is followed consistently, the only grout residue remaining should be easily removed by moving a dry cotton (white and lint free) or microfiber cloth across the surface of the tile in a circular motion two or three times.

After grouting, inspect the area to see if you notice a film/haze on the surface of the tile. If you notice a film or haze, lightly tap the grout joints with your finger to ensure the joint is firm and the grout does not transfer to your finger tip. When joint is firm, use an alcohol-based clear glass cleaner (for luxury vinyl tile, test first on a separate piece for compatibility) to remove any residual film or haze. Spray alcohol-based clear glass cleaner on a nylon cleaning pad (such as a microfiber towel or 3M® Doodlebug™) designed for delicate surfaces. Rub the cleaning pad lightly over the urethane haze on the tile being careful not to disturb the grout joints.

Excessive haze may require a direct spray on the surface of the tile, more dwell time or repeated cleaning. Do not flood surface with cleaner. Allow cleaner to rest on the tile/stone surface for at least 60 seconds to ensure sufficient penetration. Use a damp sponge and clean water to rinse and remove film and cleaner. Finish by drying the tile surface with a clean towel or cloth. Remove any remaining film/haze before moving to next area to be grouted. This process eliminates the chances of having to go back for secondary haze removal (next day).

NOTE: Videos for the prevention and removal of haze are available at www.youtube.com/BostikUSA.

18 LB. UNIT COVERAGE CHART (FT2)

Tile Size 1⁄16" 1⁄8" 3⁄16" 1⁄4" 3⁄8" 1⁄2"

1" x 1" x 1⁄4" 63 32 - - - -

2" x 2" x 1⁄4" 126 63 - - - -

3" x 6" x 5⁄16" 402 206 140 108 - -

4" x 4" x 5⁄16" 382 196 134 102 - -

41⁄4" x 41⁄4" x 5⁄16" 214 107 71 54 36 27

4" x 8" x 1⁄2" 168 84 56 42 28 21

6" x 6" x 1⁄2" 189 95 63 47 32 24

8" x 8" x 3⁄8" 337 168 112 84 56 42

12" x 12" x 3⁄8" 505 253 168 126 84 63

13" x 13" x 3⁄8" 547 274 182 137 91 68

16" x 16" x 3⁄8" 673 337 224 168 112 84

18" x 18" x 3⁄8" 758 379 253 189 126 95

24" x 24" x 3⁄8" 1010 505 337 253 168 126

9 LB. UNIT COVERAGE CHART (FT2)

Tile Size 1⁄16" 1⁄8" 3⁄16" 1⁄4" 3⁄8" 1⁄2" 1" x 1" x 1⁄4" 32 16 - - - -

2" x 2" x 1⁄4" 63 32 - - - -

3" x 6" x 5⁄16" 201 103 70 54 - -

4" x 4" x 5⁄16" 191 98…