MINISH3B S-001 NOTES_REV 06-11-2024.pdf
PDF 195 KB Posted
- Solicitation number
- W912DS24B0001
About this file
This document appears to be a set of general notes and requirements for a structural design related to a federal construction contract opportunity. The key details are:
The document provides codes, specifications, and general notes that apply to the structures in this contract. It covers requirements for verifying existing conditions, contractor responsibilities, submittal of shop drawings, concrete reinforcement, structural steel, and sheet piling. The design is based on several industry codes and standards.
The related federal contract opportunity is a solicitation for the construction of a new sheet pile bulkhead wall as part of the Joseph G. Minish Passaic River Waterfront Park and Historic Area project in Newark, NJ. The project is valued between $10-25 million and has a period of performance of 425 calendar days. The solicitation will be issued as an unrestricted full and open competition with HUBZone preference. Interested parties must be registered in SAM and on the Contract Opportunities website to access the solicitation.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CODES & SPECIFICATIONS
THE FOLLOWING REQUIREMENTS TOGETHER WITH THE
PROJECT PLANS AND SPECIFICATIONS, APPLY TO THE
STRUCTURES IN THIS CONTRACT.
GENERAL NOTES
1. ALL EXISTING CONDITIONS SHALL BE VERIFIED IN THE
FIELD BY THE CONTRACTOR PRIOR TO CONSTRUCTION.
2. ALL DIMENSIONS AND ELEVATIONS INDICATED ON THE
STRUCTURAL DRAWINGS SHALL BE VERIFIED BY THE
CONTRACTOR AND SHALL BE COORDINATED WITH
THOSE INDICATED ON THE ARCHITECTURAL, AND CIVIL
DRAWINGS. REPORT ALL DISCREPANCIES TO THE C.O.
FOR RESOLUTION BEFORE PROCEEDING.
3. THE CONTRACTOR IS RESPONSIBLE FOR ALL MEANS
AND METHODS OF CONSTRUCTION THROUGHOUT THE
PROJECT DURATION. HE SHALL PROVIDE ADEQUATE
BRACING, SHORING, AND INSTITUTE MEASURES
NECESSARY TO PROTECT ALL WORK FROM DAMAGE,
BREAKAGE, SETTLEMENT, OR COLLAPSE THAT MAY
RESULT FROM THE CONSTRUCTION ACTIVITY.
4. TYPICAL DETAILS AND NOTES ARE SHOWN ON
STRUCTURAL DRAWINGS. TYPICAL DETAILS SHALL BE
APPLICABLE TO ALL PARTS OF THE STRUCTURAL WORK
EXCEPT WHERE SPECIFICALLY REQUIRED OTHERWISE
BY CONTRACT DOCUMENTS. DETAILS NOT SPECIFICALLY
SHOWN SHALL BE SIMILAR TO THOSE SHOWN FOR THE
MOST NEARLY SIMILAR CONDITION.
5. THE CONTRACTOR SHALL SUBMIT COMPLETE SHOP
DRAWINGS FOR ALL PARTS OF THE WORK INCLUDING
DESCRIPTION OF TEMPORARY BRACING,
CONSTRUCTION METHODS, AND SEQUENCING WHERE
APPLICABLE. NO PERFORMANCE OF THE WORK
INCLUDING, BUT NOT LIMITED TO, FABRICATION OR
ERECTION OF NEW STRUCTURAL ELEMENTS, SHALL
COMMENCE WITHOUT PRIOR REVIEW AND APPROVAL OF
THE SHOP DRAWINGS BY THE COR.
6. CONTRACTOR SHALL COORDINATE HIS WORK WITH THE
CO’S DESIGNATED INSPECTORS. NO WORK TO BE
INSPECTED SHALL BE BUILT UPON OR OTHERWISE
COVERED BEFORE INSPECTIONS HAVE BEEN
COMPLETED.
STRUCTURAL STEELCONCRETE
REINFORCEMENT
1. REINFORCEMENT WORK OF DETAILING, FABRICATION,
AND ERECTION SHALL CONFORM TO “BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE”(ACI 318)
AND THE LATEST EDITION OF “DETAILS AND DETAILING
OF CONCRETE REINFORCEMENT”(ACI 315).
2. REINFORCING STEEL SHALL CONFORM TO ASTM A615
(GRADE 60) EPOXY COATED.
3. PROVIDE AND SCHEDULE ON SHOP DRAWINGS THE
NECESSARY ACCESSORIES TO HOLD REINFORCEMENT
SECURELY IN POSITION. ALL REINFORCEMENT SHALL BE
SECURELY TIED IN PLACE AT THE POSITION SHOWN ON
THE DRAWINGS BEFORE POURING CONCRETE.
4. WHERE CONTINUOUS REINFORCEMENT IS CALLED FOR,
IT SHALL BE EXTENDED CONTINUOUSLY AROUND
CORNERS AND LAPPED AT NECESSARY SPLICES OR
HOOKED AT DISCONTINUOUS ENDS. LAPS SHALL BE
CLASS B TENSION LAP SPLICES, UNLESS NOTED
OTHERWISE.
5. REINFORCING STEEL SPLICES AND ANCHORAGE
LENGTHS SHALL BE IN COMPLIANCE WITH ACI 318,
UNLESS NOTED OTHERWISE ON THE DRAWINGS.
6. WHERE REQUIRED, DOWELS SHALL MATCH BAR SIZE
AND NUMBER OF MAIN REINFORCING, UNLESS NOTED
OTHERWISE.
7. REINFORCEMENT SHALL NOT BE TACK WELDED.
8. ALL CONCRETE CLEAR COVER TO BE 4".
TIE RODS
ABBREVIATIONS
CL CENTERLINE
CLR. CLEAR
CONC. CONCRETE
CONT. CONTINUOUS
C.C. CENTER-TO-CENTER
DIA. DIAMETER
EL. ELEVATION
E.W. EACH WAY
MAX. MAXIMUM
MIN. MINIMUM
O.C. ON CENTER
PL PLATE
STA. STATION
STIFF. STIFFENER
TYP. TYPICAL
T&B TOP AND BOTTOM
U.O.N. UNLESS OTHERWISE NOTED
SHEET PILING
1. CAST-IN-PLACE CONCRETE WORK SHALL CONFORM TO
"BUILDING CODE REQUIREMENTS FOR REINFORCED
CONCRETE" (ACI 318-14), "CODE REQUIREMENTS FOR
ENVIRONMENTAL ENGINEERING CONCRETE
STRUCTURES" (ACI 350) AND "SPECIFICATIONS FOR
STRUCTURAL CONCRETE FOR BUILDINGS" (ACI 301).
CONCRETE PLACEMENT SHALL CONFORM TO THE
LATEST EDITION OF "GUIDE FOR MEASURING, MIXING,
TRANSPORTING AND PLACING CONCRETE" (ACI 304). IN
CASE OF CONFLICT, THE MOST STRINGENT
REQUIREMENTS SHALL APPLY.
2. ALL CONCRETE SHALL BE NORMAL WEIGHT CONCRETE.
MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT
28 DAYS SHALL BE 4000 PSI.
3. ALL ABOVE GRADE CONCRETE SHALL CONTAIN A
CORROSION INHIBITING ADMIXTURE. A
MICROCRYSTALLINE ADMIXTURE SHALL BE ADDED TO
THE CONCRETE MIX PER THE SPECIFICATIONS.
4. CONTROL/CONSTRUCTION JOINTS SHALL BE PROVIDED
AS INDICATED ON THE DRAWINGS OR AS APPROVED BY
THE ENGINEER. THE CONTRACTOR SHALL SUBMIT
SHOP DRAWINGS INDICATING THE LOCATIONS OF ALL
CONSTRUCTION JOINTS. WHERE NOT SHOWN,
CONSTRUCTION JOINTS SHALL BE LOCATED AT NO
MORE THAN 40’-0” ON CENTER.
5. ALL EXPOSED CONCRETE EDGES SHALL HAVE 3/4"
CHAMFER.
1. PLATES AND STEEL CHANNELS SHALL CONFORM TO
ASTM A36.
2. WELDING SHALL CONFORM TO THE STRUCTURAL
WELDING CODE D1.1, LATEST EDITION.
3. WELDING ELECTRODES SHALL BE E70XX UNLESS
NOTED OTHERWISE.
4. BOLTS SHALL CONFORM TO ASTM F3125 GR. A325.
WASHERS SHALL CONFORM TO ASTM F436. NUTS
SHALL CONFORM TO ASTM A563.
5. ALL ALLOWABLE BOLT LOADS SHALL BE THOSE GIVEN
IN THE AISC MANUAL.
6. A MINIMUM OF TWO (2) BOLTS SHALL BE USED FOR ALL
CONNECTIONS UNLESS NOTED OTHERWISE.
7. WALERS AND ALL ASSOCIATED HARDWARE SHALL BE
HOT-DIPPED GALVANIZED PER ASTM A123 AND ASTM
A153.
8. ALL WALER BOLTS AND TIE ROD HOLES THRU SHEET
PILING SHALL BE FIELD DRILLED STANDARD SIZED
HOLES. FLAME CUTTING IS NOT PERMITTED. SEE
SPECIFICATION 31 41 16.
9. CONNECTIONS BETWEEN SHEET PILING AND WALER
CHANNELS SHALL BE ASTM F1554 GRADE 105
THREADED ROD.
1. SHEET PILING SHALL BE ASTM A690 GRADE 50.
2. STEEL WIDE FLANGE BEAM PILES SHALL BE ASTM A690
GRADE 50.
3. IF USING STANDARD STEEL GRADE A572, SHEET PILING
AND STEEL PILES SHALL BE COATED WITH COAL TAR
EPOXY. IF USING A690 STEEL, NO COAL TAR EPOXY
COATING IS REQUIRED. SEE SPECIFICATIONS AND
MANUFACTURER REQUIREMENTS.
4. THE CONTRACTOR SHALL PRE-DRILL FOR ALL WIDE
FLANGE BEAM PILES.
5. FOR SHEET PILING, THE CONTRACTOR SHALL PLAN TO
INSTALL USING EQUIPMENT SUITABLE FOR HARD
DRIVING CONDITIONS.
6. DURING INSTALLATION OF THE DEAD-MAN SHEETING, IF
OBSTACLES ARE ENCOUNTERED AND CAUSE EARLY
REFUSALS (SEE SPECIFICATION FOR DESCRIPTION), THE
CONTRACTOR CAN EXCAVATE AND REMOVE OBSTACLES
AND THEN BACKFILL EXCAVATED MATERIAL, OR CAN
RE-ALIGN THE DEAD-MAN SHEETING AS LONG AS
MINIMUM DIMENSION SHOWN IN PARTIAL PLANS IS
MAINTAINED.
7. THE CONTRACTOR SHALL PRE-DRILL HOLES OF A SIZE
MAXIMUM 6 INCHES LARGER THAN SIZE OF THE WIDE
FLANGE BEAM PILE. ANY VOID SPACE REMAINING
AROUND THE PILE AFTER COMPLETION OF DRIVING
SHALL BE FILLED WITH GROUT AS SPECIFIED. THE USE
OF SPUDS SHALL NOT BE PERMITTED IN LIEU OF
PRE-DRILLING. MATERIAL RESULTING FROM DRILLING
HOLES SHALL BE DISPOSED OF AS APPROVED IN THE
CONTRACT.
THE DESIGN SHOWN ON THESE DRAWINGS IS BASED ON THE
FOLLOWING CODES, SPECIFICATIONS, AND STANDARDS.
1. INTERNATIONAL BUILDING CODE (IBC) NEW JERSEY
EDITION, 2015
2. AMERICAN SOCIETY OF CIVIL ENGINEERS (ASCE)
MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES (ASCE 7-10)
3. AMERICAN CONCRETE INSTITUTE (ACI) BUILDING CODE
REQUIREMENTS FOR REINFORCED CONCRETE (ACI
318-14)
4. AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)
STEEL CONSTRUCTION MANUAL (14TH EDITION)
5. UNIFIED FACILITIES CRITERIA (UFC) 1-200-01, “GENERAL
BUILDING REQUIREMENTS”(20 JUNE 2016)
6. UNIFIED FACILITIES CRITERIA (UFC) 3-301-01,
“STRUCTURAL ENGINEERING”(20 JUNE 2016)
1. TIE ROD STEEL SHALL BE ASTM A615, GRADE 75 AND
SHALL BE FACTORY PRE-GROUTED FOR DOUBLE
CORROSION PROTECTION
2. COUPLERS AND TURNBUCKLES AS REQUIRED BY
CONTRACTOR SHALL DEVELOP 100% OF THE ULTIMATE
STRENGTH OF THE TIE ROD.
DESIGN CRITERIA
1. PROJECT LOADING
1.A. SURCHARGE:
SURCHARGE LOAD 500 PSF
1.B. SEISMIC:
RISK CATEGORY II
IMPORTANCE FACTOR 1.00
Ss 0.287 S1 0.06
SITE CLASS D
SEISMIC DESIGN CATEGORY B
M
IN
IS
H
3B S-
N O
TE
S.
dw g
V.
A nt es
T.
S hi u
J.
G ou ld
S.
A pt e
S-001
G
EN
ER
AL
N O
TE
S
23 40
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
US Army Corps of Engineers
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
W
SP
U
SA
M O
U N
T
KE
M
BL
E
AV
EN
U
E
ST
E.
M
O R
R
IS
TO
W
N , N
EW
J
ER
SE
Y
N
EW
Y O
R K
D
IS
TR
IC
T
F
ED
ER
AL
P
LA
ZA
N
EW
Y
O R
K, N
EW
Y
O R
K
W
2D S-
-D
-0
JU
N
E
FI
LE
N
AM
E:
AN
SI
D
W
2D S-
-B
-0
JO
SE
PH
G
. M
IN
IS
H
PA
SS
AI
C
R
IV
ER
W
AT
ER
FR
O
N T
PA
R
K
AN
D H
IS
TO
R
IC
A R
EA
N
EW
AR
K, N
EW
J
ER
SE
Y C
O N
ST
R
U C
TI
O
N C
O N
TR
AC
T
(F O
R M
ER
LY
B)
RTA SUBMISSION
SHEET OF
/1
1/
R
EV
SH
EE
T
PI
LI
N
G N
O
TE
| Sheets and Views |
| S-001 |
File details come from the government source that posted it. Updated .