This document provides details for a federal construction contract solicitation issued by the Department of the Army Corps of Engineers Engineering District New York. The solicitation is for the Building 620 Whole Building Repair Project at the United States Military Academy in West Point, New York. The project entails full renovation of the unaccompanied personnel housing barracks in Building 620 and associated facilities. Renovations will address deteriorating and failing building systems including structural, roofing, windows, exterior walls, interiors, mechanical, electrical and plumbing systems. Hazardous material abatement is also included. The period of performance is approximately 610 calendar days from the notice to proceed date. The estimated magnitude of construction is between $25 million and $100 million. The solicitation is available electronically through the System for Award Management website. Questions can be directed to the point of contacts provided.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
p
PRE-RENOVATION HAZARDOUS MATERIALS
SURVEY REPORT
BUILDING 620
United States Military Academy West Point West Point, New York
December 26, 2019
Mabbett Project No.: R2019054.000.001
Prepared for:
Burns and McDonnell 9400 Ward Parkway Kansas City, MO 64114
Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318 T. 781-275-6050 Massachusetts | Virginia | Rhode Island | New Jersey
© 2019, Mabbett & Associates, Inc.
www.mabbett.com
HAZARDOUS MATERIALS SURVEY REPORT
USMA West Point, Building 620 | West Point, NY
© 2019, Mabbett & Associates, Inc. Page i December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
ACKNOWLEDGEMENT
This Hazardous Materials Survey Report has been prepared by Mabbett and Associates, Inc. (Mabbett®) for the Pre-Renovation Survey Services required for Building 620 at the West Point Military Academy located in West Point, New York. The information presented herein is based on the facts and information conveyed to or received by Mabbett & Associates, Inc. (Mabbett®) during the preparation of this report. If any of the information provided to Mabbett that was used in preparing this report is incorrect, incomplete, or subject to change, Mabbett would wish to alter its opinion(s) accordingly. In addition, the professional opinions and information contained in this report are based solely on the requirements of the applicable regulations and technical data as known to Mabbett as of the date of this report and considered applicable to this report.
The attached Hazardous Materials Survey Report was prepared by the following Mabbett personnel:
Brendan Clune Environmental, Health & Safety Specialist
This report has been reviewed and approved by:
Michael F. Delaney Director, Building Sciences Group
© 2019, Mabbett & Associates, Inc. Page ii December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
TABLE OF CONTENTS
SECTION PAGE
1.0 INTRODUCTION
1.1 Summary of Survey Results
1.2 Purpose and Objectives
2.0 ASBESTOS SURVEY
2.1 Sampling Methodology
2.2 Analytical Methodology
2.3 Materials with Trace Amounts of Asbestos
2.4 Summary of Asbestos Containing Materials Findings
3.0 LEAD-CONTAINING PAINT SURVEY
4.0 INVENTORY OF OTHER HAZARDOUS MATERIALS
5.0 MOLD SURVEY
6.0 RADON SURVEY
7.0 CONCLUSIONS AND RECOMMENDATIONS
7.1 Asbestos
7.2 Lead Containing Paint
7.3 Other Hazardous Materials
7.4 Mold
7.5 Radon
8.0 LIMITATIONS
TABLES
Table 1 – Summary of Identified ACM (in text) Table 2 – Summary of Lead Paint Chip Analytical Results (in text) Table 3 – Inventory of Other Hazardous Materials (in text) Table 4 – Fungal Direct Examination Results (in text)
FIGURES
HMB-1 – Basement Sampling Location Plan HMB-2 – 1st Floor Sampling Location Plan HMB-3 – 2nd Floor Sampling Location Plan HMB-4 – 3rd Floor Sampling Location Plan
© 2019, Mabbett & Associates, Inc. Page iii December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
APPENDICES
Appendix A – Accreditation Certificates Appendix B – Summary of ACM Building Survey Results, Including Negative Results Appendix C – Asbestos Laboratory Reports and Chain of Custody Appendix D – Photograph of ACM Appendix E – Lead Paint Chip Laboratory Reports and Chain of Custody Appendix F – Mold Laboratory Report and Chain of Custody Appendix G – EnviroMed Radon Test Report
© 2019, Mabbett & Associates, Inc. 1 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
1.0 INTRODUCTION
Mabbett and Associates, Inc. (Mabbett®) performed surveys for regulated building materials (RBM) as part of Pre-Renovation Building Services required for Building 620, at West Point Military Academy located in West Point, New York. The purpose of this survey was to assess Building 620 for the presence of regulated building materials, including asbestos-containing materials (ACMs) lead-containing materials and other hazardous materials (OHMs,) as well as perform sampling for mold and radon. Building 620 is a 4-story, approximately 70,000 square foot (SF) structure and was a vacant army barracks at the time of the survey.
Site surveys were performed by a team of Mabbett inspectors, with support from EnviroMed Services LLC (EnviroMed), November 13-14, 2019. Team member accreditation certificates are provided in Appendix A.
Site surveys consisted of the following activities:
A review of facility building information;
An Asbestos Containing Material (ACM) survey of suspect materials (Analysis by Polarized Light Microscopy [PLM] and Transmission Electron Microscopy [TEM]); and Limited Lead Containing Paint (LCP) sampling (Analysis by atomic absorption [AA]);
A visual estimation and inventory of other hazardous materials (OHM);
A visual survey and limited sampling of building surfaces for the presence of mold and fungal spores, and;
Ambient air sampling for the presence of radon.
The survey was limited to the building identified in this report. Sampling locations were determined based upon inspection of each area. Areas and materials outside of this scope of work were not surveyed by Mabbett. Survey and sampling of the roof systems was not performed.
1.1 Summary of Survey Results
Bulk samples of suspected ACM were collected and submitted to a certified analytical laboratory for asbestos analysis by PLM and TEM using stop positive methodology as required by New York State Environmental Laboratory Approval Program (ELAP). Paint chip samples were collected and submitted to a certified analytical laboratory for lead content analysis using atomic absorption spectroscopy. Tape lift samples of building surfaces were collected and submitted to a certified analytical laboratory for the presence of mold / mold spores. Approved air monitoring devices were placed in designated sample locations for a 48-hour period to sample the air inside the building for the presence of radon. The survey efforts yielded the following results and conclusions:
One-hundred and thirty-six (136) bulk samples for suspect ACM were collected in the building.
Based on laboratory analysis of suspect ACM, two (2) of the materials sampled contained asbestos greater than 1%. The Environmental Protection Agency (EPA) and the Occupational Safety and Health Administration (OSHA) defines ACM as any material that contains greater than one percent (>1%) asbestos.
Eight (8) of the collected samples contained asbestos less than 1% and are considered trace asbestos materials.
Twenty (20) paint chip samples from building surfaces were collected in the building for laboratory analysis and reporting.
Based on laboratory analysis of paint chips, four (4) of the collected samples revealed concentrations of lead in paint that exceeded the U.S. Department of Housing and Urban Development (HUD) threshold of 0.5 percent by weight.
© 2019, Mabbett & Associates, Inc. 2 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
Based on laboratory analysis of tape lift samples collected of surfaces within the building, thirteen (13) surfaces sampled contained rare or higher levels of fungal spores, and five (5) surfaces contained high levels of fungal spores.
The results of indoor air quality tests for the presence of radon indicated that radon levels in Building 620 do not exceed the US EPA’s threshold for taking further action (4.0 pico Curies / L of air).
1.2 Purpose and Objectives
The hazardous material survey was comprised of three primary project tasks including:
Evaluation of existing site conditions and formulation of a sampling plan.
Site survey to collect building material samples for laboratory analysis.
Development of this Hazardous Materials Survey Report.
This project was designed to accomplish two primary objectives: to collect a representative number of building materials for laboratory analysis and reporting; and to use data from the laboratory analysis efforts to estimate the volume of hazardous materials present within the building’s interior and exterior for Burns & McDonnell’s subsequent use in development of an abatement scope and cost. These two objectives were met through a combination of a site visit and inspection to collect building material samples for laboratory analysis; and interpretation of qualitative data collected in the field; and the quantitative laboratory data generated from analysis of the building materials as summarized in this survey report.
2.0 ASBESTOS SURVEY
A visual screening inspection was conducted by a New York State licensed asbestos inspector to identify locations of suspect ACM and conceptualize the sampling program. Only areas that were accessible during the field work phase were inspected, with reasonable efforts made during the initial field survey work to access areas as necessary to complete the asbestos survey and sampling program.
2.1 Sampling Methodology
Bulk asbestos samples were collected using EPA National Emissions Standards for Hazardous Air Pollutants (NESHAP), 40 CFR Part 763, and Asbestos Hazard Emergency Response Act (AHERA) protocols. Bulk suspect ACM sampling was generally conducted according to the following sampling protocol:
Friable surfacing material:
At least three (3) bulk samples collected from each homogeneous area that is 1,000 ft2 or less.
At least five (5) bulk samples collected from each homogeneous area that is greater than 1,000 ft2 but less than or equal to 5,000 ft2.
At least seven (7) bulk samples collected from each homogeneous area that is greater than 5,000 ft2.
Thermal system insulation:
At least three (3) bulk samples collected from each homogeneous area of thermal system insulation.
At least one (1) bulk sample collected from each homogeneous area of patched area of thermal system insulation.
Sufficient samples collected from elbows and fittings to determine if they contain ACM.
© 2019, Mabbett & Associates, Inc. 3 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
Bulk samples were not collected from any homogeneous area where the state licensed asbestos inspector determined that the thermal system insulation is fiberglass, foam glass, rubber, or other non-ACM.
Miscellaneous material:
At least two (2) bulk sample collected from each homogeneous area that is less than 100 ft2.
At least three (3) bulk samples collected from each homogeneous area that is greater than 100 ft2.
Areas that were inaccessible, or where the survey was limited to visual observation only, are identified below:
Within walls Within fire doors Enclosed pipe/duct chases Inside mechanical equipment/ductwork Above fixed drywall or plaster ceilings Electrical equipment
2.2 Analytical Methodology
The collected bulk samples were submitted under chain of custody (COC) procedures to Ameri Sci of New York, NY for PLM and TEM analysis as required by the New York State Environmental Laboratory Approval Program. PLM analysis of friable materials was performed using NYS ELAP Method 198.1. Samples of Non- Friable Organically Bound (NOB) materials were analyzed by PLM (NYS ELAP Method 198.6) subsequent to matrix reduction. NOB samples that were identified as non-ACM by PLM methods were re-analyzed by TEM (NYS ELAP Method 198.4) for confirmation purposes. AmeriSci is accredited by the American Industrial Hygiene Association (AIHA) and participates in the National Voluntary Laboratory Accreditation Program
(NVLAP).
All bulk sample results from this inspection are summarized in Appendix B, Summary of ACM Building Survey Results. The EPA, Occupational Safety and Health Administration (OSHA), and Part 56 of Title 12 of the Official Compilation of Codes, Rules and Regulations of the State of New York (12 NYCRR Part 56) defines any material that contains greater than one percent (>1%) asbestos as being an ACM. As such, the analytical laboratory identified bulk samples as positive for asbestos that met the regulatory criteria of greater than one percent (>1%) asbestos. The laboratory report and COC documentation are provided in Appendix C of this report.
2.3 Materials with Trace Amounts of Asbestos
Where laboratory analysis identified trace amounts of asbestos, that is, less than 1%, the material sampled has generally not been listed as ACM in this report. This determination is consistent with New York State and US EPA definitions of ACM. Federal OSHA regulations may require additional evaluation of materials containing trace amounts of asbestos prior to activities which could cause release of fibers into the air.
Evaluations of materials with trace amounts of asbestos and of the fiber release potential of work practices have not been addressed in this report.
© 2019, Mabbett & Associates, Inc. 4 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
2.4 Summary of Asbestos Containing Materials Findings
Mabbett identified forty-nine (49) types of homogenous materials and collected one-hundred and thirty-six
(136) representative bulk ACM samples. Two (2) materials were determined to be ACM. These were; the bottom layer 12”x12” White Floor Tile and the Mastic associated with the bottom layer 12”x12” White Floor Tile. These materials were both located throughout Floors 1 and 2. Asbestos sampling locations and results are identified on Figures HMB-1, HMB-2, HMB-3 and HMB-4. Photos of identified ACM are included in Appendix D of this report. Estimated quantities of materials identified as ACM or assumed to be ACM are presented in Table 1 below:
TABLE 1
Summary of Identified ACM
USMA West Point, Building 620 West Point, New York
Location Description of Material Estimated Quantity
Amount Unit
Rooms 101-110, 114, 115, 116, 117, 117A, 119-128, 132, 133, 134, 135, 135A, 201-210, 214, 215, 216, 217, 217A, 219-228, 232, 233, 234, 235, 235A, 236-251, 1st Floor North & South Hallways, 2nd Floor North
Main and East Wing Hallways
Bottom Layer 12"x12" White Floor Tile and
Associated Black Mastic 26,000 Square
Feet
3.0 LEAD-CONTAINING PAINT SURVEY
Limited sampling of painted surfaces was conducted on November 14th, 2019. The limited LCP survey included the collection of twenty (20) paint chips from materials and surfaces that may be impacted by the proposed work. Paint chip samples were submitted under standard COC procedures to EMSL Analytical Services, Inc. of Woburn, MA. Analysis was conducted using AA EPA method SW846-3050B/700B. The laboratory analytical report is included in Appendix E of this report.
The results of the limited LCP sampling are summarized in Table 2 below:
TABLE 2
Summary of Lead Paint Chip Analytical Results
USMA West Point, Building 620 West Point, New York
Sample # Location Color Result (%wt)
Pb-01 Room B02 Planks Above Drop Ceiling White 0.55 Pb-02 Room B05 Wall Off-White 0.68 Pb-03 Room B01 Wall Off-White 0.011 Pb-04 3rd Floor Above Drop Ceiling Cream 31 Pb-05 1st floor South Wing Hall Wall White <0.008 Pb-06 1st Floor North Wing Hall Wall Blue <0.008 Pb-07 1st Floor South Wing Hall Blue <0.008
© 2019, Mabbett & Associates, Inc. 5 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
TABLE 2
Summary of Lead Paint Chip Analytical Results
USMA West Point, Building 620 West Point, New York
Sample # Location Color Result (%wt)
Pb-08 1st Floor South Wing Hall White <0.008 Pb-09 Room 131 Wall White <0.012 Pb-10 1st Floor East Wing Hall Wall Light Blue <0.008 Pb-11 1st Floor East Wing Door Frame Deep Blue <0.028 Pb-12 2nd Floor South Wing Hall Wall Blue <0.008 Pb-13 Room B01 Stairs Floor Grey 0.013 Pb-14 1st Floor 122 Inner Wall Beige 21 Pb-15 Room 027 Wall Off-White <0.008 Pb-16 1st Floor North Wing Door Frame Deep Blue <0.036 Pb-17 2nd Floor North Wing Hall Wall White <0.008 Pb-18 Room B03 Stairs Black <0.015 Pb-19 Room B05 Door Frame Deep Green <0.027 Pb-20 Room B09 Door Frame Maroon <0.01
The Occupational Safety & Health Administration (OSHA) does not recognize a “safe” level of lead in paint.
Depending on the method of removal used, even trace amounts of lead in paint may result in airborne concentrations of lead during removal. An employer or contractor who disturbs or removes lead paint must comply with OSHA Standard 29 CFR 1926.62, “Lead Exposure in Construction; Interim Final Rule.”
4.0 INVENTORY OF OTHER HAZARDOUS MATERIALS
A visual screening and inventory was conducted by Mabbett staff to identify quantities of other potential hazardous, non-hazardous, or regulated building materials in order to define an inventory of these materials for future relocation or disposal purposes. The survey included a visual estimation of the following suspect materials:
Light Ballasts (associated with fluorescent light tubes) Light Tubes (e.g., Fluorescent light tubes and HID lamps that may contain mercury or lead) Switches (i.e., mercury switches or gauges) Ozone Depleting Substances (e.g., chlorofluorocarbons contained in air conditioning and refrigeration equipment.
Batteries (i.e., lead acid, nickel cadmium and lithium batteries) Containerized Wastes Miscellaneous (e.g., aboveground storage tanks, smoke detectors, fire suppression systems, hydraulic door stops, solids, liquids, and staining from process areas)
A summary of this visual inventory is presented below in Table 3.
© 2019, Mabbett & Associates, Inc. 6 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
TABLE 3
OHM Inventory
USMA West Point, Building 620 West Point, New York
Material Quantity Unit Electronic Light Ballasts 300 Each
4' Fluorescent Light Bulbs 330 Each U-Shaped Fluorescent Light Bulbs 100 Each
Vanity Fluorescent Light Bulbs 50 Each Batteries Associated with Emergency Lighting and Exit Signs 30 Each
Walk-In Refrigerators 2 Each Refrigerators 4 Each Microwaves 7 Each
Electric Range 1 Each Air Compressors 2 Each
5.0 MOLD SURVEY
Mabbett conducted limited sampling of building surfaces throughout Building 620 for the presence of mold, mold spores and other indicators of the presence of fungal growth. These samples were collected by applying direct exam tape lifts to various surfaces throughout the building for determining the presence of fungal spores and type of fungi present. These samples were submitted under standard COC procedures to EMSL Analytical Services, Inc. of Woburn, MA. Samples were analyzed using EMSL Method MICRO-SOP-200.
The laboratory analytical report is included in Appendix F of this report.
Mabbett collected samples from a total of twenty (20) surfaces throughout Building 620. Of these 20 samples, thirteen (13) surfaces sampled contained rare or higher levels of fungal spores, and five (5) surfaces contained high levels of fungal spores.
The results of the tape lift sampling are summarized in Table 4 below:
TABLE 4
Fungal Direct Examination Results
USMA West Point, Building 620 West Point, New York
Sample No. Location/Description Sample Type FDE Results / Type
TL- 01 3rd Floor / Pipe Jacket Tape- Lift Cladosporium - High TL-02 3rd Floor / HVAC Cover Tape- Lift None Detected TL-03 3rd Floor / Stair Railing Tape- Lift None Detected
TL-04 2nd Floor Room 218 / Damaged Floor Tape- Lift Aspergillus/Penicillium - Rare
TL-05 2nd Floor Corridor / Damaged Ceiling Tile Tape- Lift None Detected
© 2019, Mabbett & Associates, Inc. 7 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
TABLE 4
Fungal Direct Examination Results
USMA West Point, Building 620 West Point, New York
Sample No. Location/Description Sample Type FDE Results / Type
TL-06 2nd Floor Room 200 / Wall Tape- Lift Stachybotrys/Memnoniella - High
TL-07 2nd Floor North Stair / Radiator Tape- Lift Epicoccum - Rare
TL-08 2nd Floor Corridor / Top Of Ceiling Tape- Lift None Detected
TL-09 2nd Floor Corridor / Floor Tape- Lift None Detected
TL-10 2nd Floor West Wing / Damaged Floor Tape- Lift Cladosporium - Rare ;
Scopulariopsis/Microascus - High
TL-11 2nd Floor West Wing / Damaged Block Wall Tape- Lift None Detected
TL-12 1st Floor Room 107 / Window Sill Tape- Lift
Alternaria - Rare ; Ascospores - Rare ;
Basidiospores - Rare ; Bipolaris++ - Rare ;
Cladosporium - Rare ; Epicoccum - Rare ;
Myxomycetes - Low ; Pithomyces - Rare
TL-13 1st Floor Room 100 / Counter Tape- Lift None Detected TL-14 1st Floor West Wing / Carpet Tape- Lift Ascospores - Rare TL-15 1st Floor Room 101 / Floor Tape- Lift Basidiospores - Rare; Pithomyces - Rare TL-16 1st Floor Room 114 / Ceiling Tape- Lift Chaetomium - High
TL-17 Basement West Side / Concrete Sill Tape- Lift Myxomycetes - Rare
TL-18 Basement West side / Stair Tape- Lift Cladosporium - High TL-19 Basement North Side / Locker Tape- Lift None Detected TL-20 Basement South Side / Floor Tape- Lift Basidiospores - Rare
6.0 RADON SURVEY
Mabbett team member EnviroMed, as part of the hazardous materials survey of Building 620, conducted ambient air sampling for radon within the building. Fourteen (14) EPA-approved monitoring devices were placed in designated sampling locations throughout the building at a minimum height of 36 inches off the floor, more than one (1) foot away from any surrounding walls and more than three (3) feet away from any windows. Samples were placed in non-utility basement areas that would be used by students, a selection of first floor dorm rooms, and in one second floor dorm room. One (1) field blank was collected for quality control and one (1) set of duplicate side-by-side samples were collected for quality control. These samples were exposed to the surrounding air for 48 hours before being sealed and transported to Aquatek Labs of Woodbridge, CT for analysis.
The Radon Test Report prepared by EnviroMed is included in Appendix G of this report.
© 2019, Mabbett & Associates, Inc. 8 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
7.0 CONCLUSIONS AND RECOMMENDATIONS
7.1 Asbestos
All identified ACM materials must be removed by a licensed asbestos abatement contractor prior to being disturbed. Any suspect materials encountered during renovation or demolition activities that were not identified in this report as being non-ACM should be assumed to be ACM unless sample results prove otherwise. Suspect ACM that may be present within the walls, above inaccessible hard ceilings, or in other inaccessible locations, should be assumed to contain asbestos if discovered during any renovation or demolition process or until otherwise verified.
7.2 Lead Containing Paint
The purpose of the limited LCP survey was to identify similar areas of LCP. During the on-site survey, representative samples of similar areas of interior and exterior building coatings were collected and analyzed for lead content. Occupational exposure to lead in construction is regulated by OSHA regulation 29 CFR 1926.62 “Lead in Construction”, as well as other applicable state and local regulations. These regulations involve the air monitoring of workers to determine exposure levels when disturbing paint containing measurable concentrations of lead. A LCP survey cannot determine the safe level of lead for the purpose of paint-disturbing activities, but is intended to provide guidance as to the locations of LCP.
Employers and contractors may use this information to better determine where worker exposures to airborne lead may occur and, through the interpretation of LCP concentration data, assess the potential magnitude of exposure to their employees and identify the controls necessary to limit health risks.
A concentration of lead greater than or equal to 0.5 mg/Kg percent by weight or 1.0 mg/cm2 exceeds EPA and HUD residential standards is considered an indicator of risk. Representative samples of LCP waste to be generated during building renovation, or following demolition but prior to disposal, should be collected and analyzed using toxicity characteristic leaching procedure (TCLP) in accordance with 40 CFR Part 261.
Management and disposal of lead containing waste must be done in accordance with all applicable local, state, and federal regulations.
7.3 Other Hazardous Materials
The purpose of the inventory for other hazardous materials as completed by Mabbett was to identify potential hazardous, non-building material substances for special handling consideration prior to any planned building demolition or rehabilitation measures. Mabbett identified items that, if removed, should be disposed of or recycled in accordance with applicable Federal and State rules for regulated materials.
Examples of such materials are light ballasts, fluorescent light tubes, batteries, and refrigeration systems.
7.4 Mold
Visible mold was observed in the building, primarily at areas of water intrusion. Analytical findings also confirmed the presence of fungal spores in the building. One particular spore type of concern was Stachybotrys, which is well-known and publicized as a mycotoxin producer. This mold/fungi type tends to grow in water-damaged building materials with high cellulose content, such as wallboard, and produce slimy spores. Because of the slimy nature, the Stachybotrys spores do not easily become airborne. It is an indication of long-term moisture within the building and on the surfaces.
© 2019, Mabbett & Associates, Inc. 9 December 26, 2019 Mabbett Project No. R2019054.000.001 S:\ADMINA\2019054\000\001\HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
7.5 Radon
The results of indoor air quality tests for the presence of radon indicated that radon levels in Building 620 do not exceed the US EPA’s threshold for taking further action (4.0 pico Curies / L of air).
8.0 LIMITATIONS
This survey report is the result of a diligent and thorough inspection for regulated building materials of the areas and materials that may be impacted by the proposed work in Buildings 620. Although a comprehensive inspection was performed with the majority of the building accessed for evaluation and sampling purposes, Mabbett does not claim to have identified all of the materials that may be present at/in the building. Mabbett has conducted this assessment with reasonable care and has performed this project within generally accepted industry standards. Mabbett makes no assurances that the information, research, and technology used to prepare this report may not change in the future, thus affecting the results reported herein.
© 2019, Mabbett & Associates, Inc. FIGURES December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
FIGURES
Sampling Location Plans
M ab be tt
A ss oc ia te s, In c.
A lfr ed C irc le
B ed fo rd
, M A
-2
T.
-2
-6 w w w .m ab be tt.
co m
LE
GE
ND ST
O
P
PO
SI
TI
VE
S
AM
PL
E
FO
R A
SB
ES
TO
S
N O
A
SB
ES
TO
S D
ET
EC
TE
D
(N
AD
SA
M
PL
E
PO
SI
TI
VE
F O
R A
SB
ES
TO
S
AP
PR
O
XI
M
AT
E
AS
BE
ST
O S
SA
M
PL
E
LO
C
AT
IO
N
A
A
A
A
Sc al e N
TS
H M
B Su rv ey
F lo or P la n
- B as em en t
U ni te d
St at es M ilit ar y Ac ad em y (U
SM
A)
W es t P oi nt , N ew Y or k
Bu ild in g-
Ba se m en t H
M B
Su rv ey P la n
Pb -0
AP
PR
O
XI
M
AT
E
LE
AD
S
AM
PL
E
LO
C
AT
IO
N
Pb -2
A, 5B
A
C
, 1 6A
, 1 6B15
A, 5B , 3
0B
B, 7C
Pb -1
B
Pb -1
Pb
-1
Pb -0
B, 7B , 1
0A
A, 7A Pb
-0 3 06
C , 0
7C , 2
4F
B, 1A , 3
1B
Pb -0
B, 1A
, 1 1B
A, 9B be tt
A ss oc ia te s, In c.
A lfr ed C irc le
B ed fo rd
, M A
-2
T.
-2
-6 w w w .m ab be tt.
co m
LE
GE
ND ST
O
P
PO
SI
TI
VE
S
AM
PL
E
FO
R A
SB
ES
TO
S
N O
A
SB
ES
TO
S D
ET
EC
TE
D
(N
AD
SA
M
PL
E
PO
SI
TI
VE
F O
R A
SB
ES
TO
S
AP
PR
O
XI
M
AT
E
AS
BE
ST
O S
SA
M
PL
E
LO
C
AT
IO
N
A
A
A
A
Sc al e N
TS
H M
B Su rv ey
F lo or P la n
- F irs t F lo or
U ni te d
St at es M ilit ar y Ac ad em y (U
SM
A)
W es t P oi nt , N ew Y or k
Bu ild in g-
Fi rs t F lo or H
M B
Su rv ey P la n
Pb -0
AP
PR
O
XI
M
AT
E
LE
AD
S
AM
PL
E
LO
C
AT
IO
N
C
, 4 1A
, 4 1B
A, 2B
, 3 6A
, 3 6B
A, 3A
Pb -1
A
B, 3B
A, 5B
Pb -1
B, 9A
, 1 9B
Pb -0
Pb -0
Pb -1
Pb -1
A, 8A
, 2 4E
F, 3D
A, 1B , 2
4D
A, 9A
Pb -1
6 48 A, 8B
, 4 9A
, 4 9B
B, 8B
C
, 2 1D
, 2 2D
, 2 3A
E, 9E
G
, 4 6D
, 4 7D
B
Pb -0
Pb -0
5 46 B, 7B
C
A
A, 2A
A, 7C
, 2 8C
Pb -0
C
B
A, 2B
E
JS
be tt
A ss oc ia te s, In c.
A lfr ed C irc le
B ed fo rd
, M A
-2
T.
-2
-6 w w w .m ab be tt.
co m
LE
GE
ND ST
O
P
PO
SI
TI
VE
S
AM
PL
E
FO
R A
SB
ES
TO
S
N O
A
SB
ES
TO
S D
ET
EC
TE
D
(N
AD
SA
M
PL
E
PO
SI
TI
VE
F O
R A
SB
ES
TO
S
AP
PR
O
XI
M
AT
E
AS
BE
ST
O S
SA
M
PL
E
LO
C
AT
IO
N
A
A
A
A
Sc al e N
TS
H M
B Su rv ey
F lo or P la n
- S ec on d
Fl oo r
U ni te d
St at es M ilit ar y Ac ad em y (U
SM
A)
W es t P oi nt , N ew Y or k
Bu ild in g-
Se co nd F lo or
H M
B Su rv ey
P la n
Pb -0
AP
PR
O
XI
M
AT
E
LE
AD
S
AM
PL
E
LO
C
AT
IO
N
Pb -1
B, 9B
B.
0B
, J S
E, 1C
, 2 2C
G , 2
6D , 4
6A , 4
7A
C
, 2 7B
, 2 8B
Pb -1
A
C
D
, 4 6C
, 4 7C
B, J S
B02
A
B
A, 7A
, 0 8D
, 0 9D
B, 2B
, 2 6C
A, 8A
D
A, 3B
, 1 4A
, 1 4B be tt
A ss oc ia te s, In c.
A lfr ed C irc le
B ed fo rd
, M A
-2
T.
-2
-6 w w w .m ab be tt.
co m
LE
GE
ND ST
O
P
PO
SI
TI
VE
S
AM
PL
E
FO
R A
SB
ES
TO
S
N O
A
SB
ES
TO
S D
ET
EC
TE
D
(N
AD
SA
M
PL
E
PO
SI
TI
VE
F O
R A
SB
ES
TO
S
AP
PR
O
XI
M
AT
E
AS
BE
ST
O S
SA
M
PL
E
LO
C
AT
IO
N
A
A
A
A
Sc al e N
TS
H M
B Su rv ey
F lo or P la n
- T hi rd F lo or
U ni te d
St at es M ilit ar y Ac ad em y (U
SM
A)
W es t P oi nt , N ew Y or k
Bu ild in g-
Th ird
F lo or H
M B
Su rv ey P la n
Pb -0
AP
PR
O
XI
M
AT
E
LE
AD
S
AM
PL
E
LO
C
AT
IO
N
Pb -0
A, 3B
A, 4B
, 4 5A
, 4 5B
A
A, 8B
A
B
A, 2B
© 2019, Mabbett & Associates, Inc. APPENDIX A December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
APPENDIX A
Accreditation Certificates
© 2019, Mabbett & Associates, Inc. APPENDIX B December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
APPENDIX B
Summary of ACM Building Survey Results, Including Negative Results
© 2019, Mabbett & Associates, Inc. Appendix B Page 1 of 4 December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
Summary of ACM Building Survey Results, Including Negative Results USMA West Point, Building 620
West Point, New York
Sample No. Sample Location Description of Material
Percent and Type of
Asbestos 01A 1st Floor East Wing Room 013 2'x4' Ceiling Tile Pin Dot NAD 01B 1st Floor East Wing Room 013 2'x4' Ceiling Tile Pin Dot NAD 02A 2nd Floor East Wing Hallway 2'x'4' Pin and Fissure Ceiling Tile NAD 02B 1st Floor South Wing Hallway 2'x'4 Pin and Fissure Ceiling Tile NAD 02C 1st Floor North Wing Hallway 2'x'4 Pin and Fissure Ceiling Tile NAD 02D 2nd Floor North Wing Hallway 2'x'4 Pin and Fissure Ceiling Tile NAD 02E 2nd Floor South Wing Hallway 2'x'4 Pin and Fissure Ceiling Tile NAD 03A Room 125 Interior Window Caulk NAD 03B Room 103 Interior Window Caulk NAD 03C Room 204 Interior Window Caulk NAD 03D Room 250 Interior Window Caulk NAD 03E Room 231 Interior Window Caulk NAD 04A Room 123/125 Bathroom 2"x2" Ceramic Floor Tile Grout NAD 04B Room 202/204 Bathroom 2"x2" Ceramic Floor Tile Grout NAD 04C Room 231 2"x2" Ceramic Floor Tile Grout NAD 05A Room B11 HVAC Unit Interior Base Paper NAD 05B Room B11 HVAC Unit Interior Base Paper NAD 06A 2nd Floor East Wing Kitchen 4" Black Covebase NAD 06B Room B05 4" Black Covebase NAD 06C Room B01 4" Black Covebase NAD 07A 2nd Floor East Wing Kitchen Mastic (Associated with 06A) NAD 07B Room B05 Mastic (Associated with 06B) NAD 07C Room B01 Mastic (Associated with 06C) NAD 08A Room 102 Sub 12"x12" White Floor Tile 4.4% Chrysotile 08B 1st Floor North Wing Stairwell Sub 12"x12" White Floor Tile NA/PS 08C 2nd Floor South Wing Stairwell Sub 12"x12" White Floor Tile NA/PS 08D 2nd Floor West Wing Kitchen Sub 12"x12" White Floor Tile NA/PS 09A Room 102 Mastic (Associated with 08A) 2.7% Chrysotile 09B 1st Floor South Wing Stairwell Mastic (Associated with 08B) NA/PS 09C 2nd Floor North Wing Stairwell Mastic (Associated with 08C) NA/PS 09D 2nd Floor East Wing Kitchen Mastic (Associated with 08D) NA/PS 10A Room B05 TSI Plaster Caps NAD 10B Room B02 TSI Plaster Caps NAD 10C Room B10 TSI Plaster Caps NAD
11A Room B02 Condensate Tank Wrap Coat Chrysotile Trace
11B Room B02 Condensate Tank Wrap Coat Chrysotile Trace
12A Rear Entry Refrigeration Unit Exterior Gold Glue dobs NAD
© 2019, Mabbett & Associates, Inc. Appendix B Page 2 of 4 December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
Summary of ACM Building Survey Results, Including Negative Results USMA West Point, Building 620
West Point, New York
Sample No. Sample Location Description of Material
Percent and Type of
Asbestos
12B Rear Entry Refrigeration Unit Exterior Gold Glue dobs NAD
13A 2nd Floor East Wing Hallway 12"x12" Ceiling Tile NAD 13B 2nd Floor East Wing Hallway 12"x12" Ceiling Tile NAD
14A 2nd Floor East Wing Hallway Gold Glue Dobs (Associated with
13A) NAD
14B 2nd Floor East Wing Hallway Gold Glue Dobs (Associated with
13B) NAD
15A Room B03 Duct Insulation Adhesive NAD 15B Room B03 Duct Insulation Adhesive NAD 16A Room B10 Brown Fire Stop NA 16B Room B10 Brown Fire Stop NA 17A Room 131 6" White Covebase NAD 17B Room Adjacent to 112 6" White Covebase NAD 18A Room 131 Mastic (Associated with 17A) NA 18B Room Adjacent to 112 Mastic (Associated with 17B) NAD 19A 1st Floor South Wing Hallway 4" Off-White Covebase NAD
19B 2nd Floor North Wing Hallway 4" Off-White Covebase Chrysotile Trace
20A 1st Floor South Wing Hallway Mastic (Associated with 19A) NAD 20B 2nd Floor North Wing Hallway Mastic (Associated with 19B) NAD 21A Room 125 12"x12" Beige Floor Tile NAD
21B Room 240 12"x12" Beige Floor Tile Chrysotile Trace
21C 2nd Floor South Wing Hallway 12"x12" Beige Floor Tile NAD 21D 1st Floor North Wing Hallway 12"x12" Beige Floor Tile NAD
22A Room 125 Mastic (Associated with 21A) Chrysotile Trace
22B Room 240 Mastic (Associated with 21B) NAD 22C 2nd Floor South Wing Hallway Mastic (Associated with 21C) NA 22D 1st Floor North Wing Hallway Mastic (Associated with 21D) NA 23A 1st Floor North Wing Hallway 2nd Layer Residual Adhesive NAD 23B Room 204 2nd Layer Residual Adhesive NAD 24A 2nd Floor North Wing Hallway Gypsum Wall Board NAD 24B 2nd Floor Lobby Gypsum Wall Board NAD 24C 1st Floor South Wing Hallway Gypsum Wall Board NAD 24D 1st Floor East Wing Room 013 Gypsum Wall Board NAD 24E Room 131 Gypsum Wall Board NAD 24F Room B01 Gypsum Wall Board NAD 24G 2nd Floor South Wing Hallway Gypsum Wall Board NAD
© 2019, Mabbett & Associates, Inc. Appendix B Page of 4 December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
Summary of ACM Building Survey Results, Including Negative Results USMA West Point, Building 620
West Point, New York
Sample No. Sample Location Description of Material
Percent and Type of
Asbestos 25A 1st Floor Lobby 12"x12" Floor Tile Grout NAD 25B 1st Floor Lobby 12"x12" Floor Tile Grout NAD 26A 3rd Floor Room Joint Compound NAD 26B Room B01 Joint Compound NAD 26C Room 240 Joint Compound NAD 26D 2nd Floor South Wing Hallway Joint Compound NAD 26E 1st Floor Lobby Joint Compound NAD 26F Room 131 Joint Compound NAD 26G 1st Floor North Wing Hallway Joint Compound NAD 27A Room 247/248 Bathroom Vinyl Flooring NAD 27B Room 231 Bathroom Vinyl Flooring NAD 27C Room 123/125 Bathroom Vinyl Flooring NAD 28A Room 247/248 Bathroom Vinyl Flooring Adhesive NA 28B Room 231 Bathroom Vinyl Flooring Adhesive NA 28C Room 123/125 Bathroom Vinyl Flooring Adhesive NA 29A Room B02 Red Fire Stop NAD 29B Room B02 Red Fire Stop NAD 30A 3rd Floor South Crawlspace Black Duct Caulk NAD 30B Room B03 Black Duct Caulk NAD 31A Room B01 Pink Fire stop NAD 31B Room B01 Pink Fire stop NAD
32A 3rd Floor South Crawlspace Beams Black Glue Dobs Chrysotile Trace
32B 3rd Floor South Crawlspace Beams Black Glue Dobs Chrysotile Trace
33A Front Basement Ceiling Gypsum Board NAD 33B 3rd Floor Room Ceiling Gypsum Board NAD 33C Room 121 Ceiling Gypsum Board NAD 33D Room 131 Ceiling Gypsum Board NAD 34A Room B01 Duct Vibration Protection NAD 34B Room B03 Duct Vibration Protection NAD 35A 3rd Floor North Crawlspace Floor Board Roof Paper NAD 35B 3rd Floor South Crawlspace Floor Board Roof Paper NAD
36A Rear Entry Refrigeration Unit Exterior White Glue Dobs NAD
36B Rear Entry Refrigeration Unit Exterior White Glue Dobs NAD
37A Room B01 Duct Tape NAD 37B Room Beyond B05 Duct Tape NAD
© 2019, Mabbett & Associates, Inc. Appendix B Page of 4 December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
Summary of ACM Building Survey Results, Including Negative Results USMA West Point, Building 620
West Point, New York
Sample No. Sample Location Description of Material
Percent and Type of
Asbestos 37C Room B03 Duct Tape NAD 38A 3rd Floor Room Ceiling Insulation NAD 38B 3rd Floor Room Ceiling Insulation NAD 39A Exterior Rear Grey Seam Caulk NAD 39B Exterior Rear Grey Seam Caulk NAD 40A Exterior East Side Concrete Window Frame Caulk NAD 40B Exterior Front Concrete Window Frame Caulk NAD 40C Exterior Rear Concrete Window Frame Caulk NAD 41A Exterior Rear Window Caulk NAD 41B Exterior Rear Window Caulk NAD 42A 1st Floor Front Entryway Concrete Floor Board NAD 42B 1st Floor Front Entryway Concreate Floor Board NAD 43A Exterior Corner East Side Red Seam Caulk NAD 43B Exterior Corner East Side Red Seam Caulk NAD 44A 3rd Floor Entry 12"x12" Lite Grey Floor Tile NAD 44B 3rd Floor Entry 12"x12" Lite Grey Floor Tile NAD 45A 3rd Floor Entry Mastic (Associated with 44A) NAD 45B 3rd Floor Entry Mastic (Associated with 44B) NAD 46A 2nd Floor South Wing Hallway 12"x12" Blue Floor Tile NAD 46B 1st Floor South Wing Hallway 12"x12" Blue Floor Tile NAD 46C 2nd Floor North Wing Hallway 12"x12" Blue Floor Tile NAD 46D 1st Floor North Wing Hallway 12"x12" Blue Floor Tile NAD 47A 2nd Floor South Wing Hallway Mastic (Associated with 46A) NA 47B 1st Floor South Wing Hallway Mastic (Associated with 46B) NA 47C 2nd Floor North Wing Hallway Mastic (Associated with 46C) NA 47D 1st Floor North Wing Hallway Mastic (Associated with 46D) NA 48A 1st Floor South Wing Hallway Entry 12"x12" Lite Blue Floor Tile NAD 48B 1st Floor South Wing Hallway Entry 12"x12" Lite Blue floor Tile NAD
49A 1st Floor South Wing Hallway Entry Mastic (Associated with 48A) Chrysotile Trace
49B 1st Floor South Wing Hallway Entry Mastic (Associated with 48B) NAD Notes: NAD=No Asbestos Detected
NA=Not Analyzed
© 2019, Mabbett & Associates, Inc. APPENDIX C December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
APPENDIX C
Asbestos Laboratory Reports and Chain of Custody
© 2019, Mabbett & Associates, Inc. APPENDIX D December 26, 2019 Mabbett Project No. R2019054.000.001 HAZMAT Survey Report West Point, NY Bldg. 620 - Final.doc
APPENDIX D
Photograph of ACM
© 2019, Mabbett & Associates, Inc. Appendix D Page 1 of 1 December 26, 2019
Bottom Layer Floor Tile and Associated Mastic
© 2019, Mabbett & Associates, Inc. APPENDIX E December 26, 2019
APPENDIX E
Lead Paint Chip Laboratory Reports and Chain of Custody
Client Sample Description ConcentrationLab ID Analyzed Weight Lead
Collected
EMSL Analytical, Inc.
5 Constitution Way, Unit A, Woburn, MA 01801 Phone/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com bostonlab@emsl.com
Attn: Michael Delaney Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
Received: 11/19/19 8:30 AM
R2019054.000
Fax: (781) 275-5651 Phone: (781) 275-6050
Project:
11/14/2019Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
131908946 CustomerID: MABB78 CustomerPO:
ProjectID:
EMSL Order:
0.2514 Site: Room B02 Planks Above Drop Ceiling Desc: White Paint
131908946-0001Pb-01 0.55 % wt11/22/2019 g11/14/2019
0.2495 Site: Room B05 Wall Desc: Off-White Paint
131908946-0002Pb-02 0.68 % wt11/22/2019 g11/14/2019
0.2503 Site: Room B01 Wall Desc: Off-White
131908946-0003Pb-03 0.011 % wt11/22/2019 g11/14/2019
0.2516 Site: 3rd Floor Above Drop Ceiling Desc: Cream Paint
131908946-0004Pb-04 31 % wt11/22/2019 g11/14/2019
0.2488 Site: 1st Floor North Wing Hall Wall Desc: White Paint
131908946-0005Pb-05 <0.0080 % wt11/22/2019 g11/14/2019
0.2511 Site: 1st Floor South Wing Hall Wall Desc: Blue Paint
131908946-0006Pb-06 <0.0080 % wt11/22/2019 g11/14/2019
0.2497 Site: 1st Floor North Wing Hall Wall Desc: Blue Paint
131908946-0007Pb-07 <0.0080 % wt11/22/2019 g11/14/2019
0.2497 Site: 1st Floor North Wing Hall Wall Desc: White Paint
131908946-0008Pb-08 <0.0080 % wt11/22/2019 g11/14/2019
0.1697 Site: Room 131 Wall Desc: White Paint
131908946-0009Pb-09 <0.012 % wt11/22/2019 g11/14/2019
0.2521 Site: 1st Floor West Wing Hall Desc: Light Blue Paint
131908946-0010Pb-10 <0.0080 % wt11/22/2019 g11/14/2019
0.0726 Site: 1st Floor West Wing Door Frame Desc: Deep Blue
131908946-0011Pb-11 <0.028 % wt11/22/2019 g11/14/2019
Eric Steele, Laboratory Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 11/22/2019 6:34:39 PM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Woburn, MA AIHA-LAP, LLC - ELLAP Accredited #180179
Initial report from 11/22/2019 18:34:39
Client Sample Description ConcentrationLab ID Analyzed Weight Lead
Collected
EMSL Analytical, Inc.
5 Constitution Way, Unit A, Woburn, MA 01801 Phone/Fax: (781) 933-8411 / (781) 933-8412 http://www.EMSL.com bostonlab@emsl.com
Attn: Michael Delaney Mabbett & Associates, Inc.
5 Alfred Circle Bedford, MA 01730-2318
Received: 11/19/19 8:30 AM
R2019054.000
Fax: (781) 275-5651 Phone: (781) 275-6050
Project:
11/14/2019Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
131908946 CustomerID: MABB78 CustomerPO:
ProjectID:
EMSL Order:
0.2493 Site: 2nd Floor North Wing Hall Desc: Blue Paint
131908946-0012Pb-12 <0.0080 % wt11/22/2019 g11/14/2019
0.1893 Site: B01 Stairs Floor Desc: Gray Paint
131908946-0013Pb-13 0.013 % wt11/22/2019 g11/14/2019
0.2508 Site: 1st Floor Room 122 Inner Wall Desc: Beige Paint
131908946-0014Pb-14 21 % wt11/22/2019 g11/14/2019
0.249 Site: Room 027 Wall Desc: Off-White Paint
131908946-0015Pb-15 <0.0080 % wt11/22/2019 g11/14/2019
0.0556 Site: 1st Floor South Wing Door Frame Desc: Deep Blue
131908946-0016Pb-16 <0.036 % wt11/22/2019 g11/14/2019
0.25 Site: 2nd Floor South Wing Hall Wall Desc: White Paint
131908946-0017Pb-17 <0.0080 % wt11/22/2019 g11/14/2019
0.1336 Site: B03 Stairs Desc: Black Paint
131908946-0018Pb-18 <0.015 % wt11/22/2019 g11/14/2019
0.075 Site: B05 Door Frame Desc: Deep Greem
131908946-0019Pb-19 <0.027 % wt11/22/2019 g11/14/2019
0.1905 Site: B09 Door Frame Desc: Maroon Paint
131908946-0020Pb-20 <0.010 % wt11/22/2019 g11/14/2019
Eric Steele, Laboratory Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 11/22/2019 6:34:39 PM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Woburn, MA AIHA-LAP, LLC - ELLAP Accredited #180179
Initial report from 11/22/2019 18:34:39
OrderID: 131908946
OrderID: 131908946
© 2019, Mabbett & Associates, Inc. APPENDIX F December 26, 2019
APPENDIX F
Mold Laboratory Report and Chain of Custody
OrderID: 131909027
OrderID: 131909027
© 2019, Mabbett & Associates, Inc. APPENDIX G December 26, 2019
APPENDIX G
EnviroMed Radon Test Report
Radon Test Report
For
Building B620 West Point Military Academy
West Point, NY
Prepared for
Mabbett & Associates, Inc.
5 Alfred Circle
Bedford, MA 01730
November 13-15, 2019
EnviroMed Project # IH-19-649
470 Murdock Ave., Meriden, CT 06450 telephone (203) 238-4846• facsimile (203) 238-4243
EnviroMed Services, Inc. B620 – West Point Military Academy Project No. IH-19-649 Radon Test Report
1.
Table of Contents
I. OVERVIEW
II. RADON FACTS AND HEALTH RISK INFORMATION
III. SAMPLING METHODOLOGY
IV. RADON IN AIR TEST RESULTS
V. WHAT DO THE RADON TEST RESULTS MEAN?
VI. CONCLUSIONS AND RECOMMENDATIONS
VI. FLOOR PLAN
IX. LABORATORY REPORT
i
EnviroMed Services, Inc. B620 – West Point Military Academy Project No. IH-19-649 Radon Test Report
1.
I. OVERVIEW
EnviroMed Services, Inc. was retained by Mabbett & Associates to conduct an initial evaluation for airborne radon at dormitory Building B620 at West Point Military
Academy. The testing was conducted in preparation for planned renovations. The building was vacant at the time of testing. HVAC systems were active during the testing period. Windows and doors were closed during and prior to the testing period. The purpose of this monitoring was to determine if the airborne radon levels in the building are below the U.S. Environmental Protection Agency (EPA) recommended action level of
4.0 pico Curies per liter of air (pCi/L).
II. RADON FACTS AND HEALTH RISK INFORMATION
Radon is the second leading cause of lung cancer. It is naturally occurring radioactive gas.
It comes from the natural breakdown (decay) of uranium, which is found in soil and rock all over the United States. Radon travels through soil and enters buildings through cracks and other holes in the foundation. Eventually, it decays into radioactive particles that can become trapped in our lungs when we breathe. As these particles in turn decay, they release small bursts of radiation. This radiation can damage lung tissue and lead to lung cancer over the course of our lifetime. Radon is colorless, odorless, and tasteless. The only way to know whether or not an elevated level of radon is present in any room is by radon testing.
III. SAMPLING METHODOLOGY
Radon in Air
A total of 14 EPA approved monitoring devices were placed in designated sample locations at a minimum of 36 inches off the floor, more than one foot from exterior walls and more than three feet from windows. Samples were placed in non-utility basement areas that would be used by students, a selection of first floor dorm rooms, and in one second floor dorm room. 1 field blank was collected for quality control. 1 set of duplicate side-by-side samples were collected for quality control. The samples were opened and allowed to be exposed to the indoor atmosphere for at least 48 hours, which complies with
United States Environmental Protection Agency (US EPA) sampling protocol. Upon
EnviroMed Services, Inc. B620 – West Point Military Academy Project No. IH-19-649 Radon Test Report completion of the monitoring, the canisters were sealed and transported to Aquatek Labs in Woodbridge, CT for analysis.
IV. RADON IN AIR TEST RESULTS
Canister Floor Level
Room Time of Set Up
11/13/19
Time of Removal 11/15/19
Radon Level pCi/L
RAD6553A
RAD6553B* B
Caged Storage
1:06pm 1:07pm 1.8 1.7
RAS4716 B
Weight Room
1:15pm 1:16pm 1.6
RAS4712 B Blank 1:15pm 1:16pm <0.5 RAS4709 1 Room 117 1:24pm 1:25pm <0.5 RAS4708 1 Room 115 1:26pm 1:27pm <0.5 RAS4713 1 Room 027 1:28pm 1:29pm 0.6 RAS4710 1 Room 104 1:30pm 1:31pm <0.5 RAS4714 1 Room 135 1:32pm 1:33pm <0.5
RAS4269 B
Locker Room
1:34pm 1:35pm 1.8
RAS4707 1 Room 131 1:36pm 1:37pm 0.6 RAS4715 1 Room 121 1:38pm 1:39pm <0.5 RAS4711 2 Room 219 1:42pm 1:43pm <0.5 RAS4695 1 Room 013 1:48pm 1:49pm 0.6
* Duplicate Sample
Use the following chart to compare the radon test results, expressed in picoCuries of radon per liter of air (pCi/L), with the EPA guidelines.
0pCi/L 5pCi/L 10pCi/L 15pCi/L 20pCi/L
⏐ ⏐ ⏐4.0 pCi/L - EPA RECOMMENDED ACTION GUIDELINE ⏐ ⏐1.3 pCi/L - Average Indoor Radon Concentration ⏐0.4 pCi/L - Average Outdoor Radon Concentration
EnviroMed Services, Inc. B620 – West Point Military Academy Project No. IH-19-649 Radon Test Report
The US EPA strongly recommends taking further action when the radon test results are 4.0 pico Curies per liter of air (pCi/L) or greater.
The national average indoor radon level is about 1.3 pCi/L. The higher the radon levels the greater the health risk to occupants. Even high levels can be reduced to below 4.0 pCi/L.
EPA recommends that you use an EPA or State-approved contractor trained to fix radon problems.
V. WHAT DO THE RADON TEST RESULTS MEAN?
If the radon level is below 4.0 pCi/L, you do not need to take action.
If the radon level is 4.0 pCi/L or greater, use the following chart to determine what should be done next. Depending upon the type of test taken, you will have to either test again or take corrective actions to reduce the radon level.
Note: All tests should meet EPA technical protocols.
Type of Test(s) If Radon Level Is 4.0 pCi/L or Greater Single Short-Term Test
Test Again*
Average of Short-Term Tests
Fix the Problem
One Long-Term Test
Fix the Problem
*If your first short-term test is several times greater than 4.0 pCi/L - for example, about 10 pCi/L or higher - you should take a second short-term test immediately.
VI. CONCLUSIONS AND RECOMMENDATIONS
Based on the results obtained from the radon testing at Building B620, West Point Military
Academy, New York, EnviroMed Services, Inc. makes the following conclusions and recommendations:
Testing indicates that radon levels are below the EPA Action Level.