Amendment 0003_Revised Drawings.pdf
PDF 2 MB Posted
- Attached to
- Building 620 Whole Building Repair Project, United States Military Academy, West Point, NY
- Solicitation number
- W912DS20B0013
About this file
This solicitation is for a firm fixed-price construction contract to renovate Building 620 at the United States Military Academy in West Point, New York. Work includes full interior and exterior renovations, replacement of failing mechanical, electrical and plumbing systems, and improvements to supporting site utilities and infrastructure. The period of performance is approximately 610 calendar days from notice to proceed. The estimated contract value is between $25-100 million. Interested vendors must register with the System for Award Management to access solicitation documents in portable document file format. The U.S. Army Corps of Engineers, New York District will evaluate proposals and make award. Contractors must report past performance using the Contract Performance Assessment Reporting System for construction contracts over $650,000. For additional information, contact the listed contracting personnel.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DN
11 12 13 14 15 16 17
A
C
D
E
F
G
I
J
K
L
M .1
11.1 12.1 13.1 14.3 14.5 15.5 15.7 16.9 18.9
A1
A-420
CQ OFFICE
TOILET
TOILET
JANITOR
RECYCLE
PRIVATE OFFICE
SHARED OFFICE
SHARED OFFICE
PRIVATE OFFICE
OPEN OFFICE
CONFERENCE
SUPPLIES
WELLNESS ROOM
STORAGE
BREAK
CORRIDOR
STAIR 5
STORAGE
STAIR 4
125A
154B
148A
141A
144A
137A
146A
142A
143A
139A
134A
133A
155A
132A
131A
135A
125B
126A
B
A-460
F1
138A136A
W01
W01
W01
W01 W01
W01
W01
W01 W01 W01
W01
W01W01
W04
W01
W01 W01
W04
W04
W04W01
W04
W04
W01
127B 127A
147A
154A
127C
F1
A-452
F4
A-452
D1
A-452
D3
A-452
D5
A-452
A1
A-452
A3
A-452
S2BE
S2BA
S2CDS2BE
H2AA
S2BD
F1BA
S2BD
S1AD
S2BA S2BAS1AD
S2BAS1AB
S1AB
S2BA
S3AAS3AA
F1BA F1BA
F1BA
S3AA S3AA
F1BA F1BA
F1BA
S3AAS3AA
S3AA S3AA
F1CA F1CA
S3AA
F1BA
F1BA
S3AA
S2BA
S2BA
S2BA
S2BA
S2BA
F1BA
S2BA
F1BA
S2BG
S2BA
S2BB
F1BA
F1CA
S2BE
A-460
F4
A-460
D1
A-460
D4
A-460
D6
MAIN LOBBY
MAILBOXES
STORAGE
VESTIBULE
VENDING
UTILITY
149A
VESTIBULE
128A
130A
127D
A14
A15
A17
A16
W01
W08
W08
S2BE
F1CA
F1CA
F1CA
F1CA
F1CA
F1CA
F1CA
F1CA
W01
W01
W01
S2BD
S2DA
E8
A-451
A18
17.9 18
A-460
F6
A20A20 A20A20
A20A20
A20A20
H2AA
H2AA
W10
EXISTING DOOR
NEW DOOR
EXISTING WALL
NEW WALL (RE: PARTITION TYPE)
PLAN LEGEND:
ROOM NAME
ROOM NUMBER
PARTITION TYPE
DOOR NUMBER
EXISTING GRID BUBBLE AND LINE
ROOM NAME
S2AA
W01 WINDOW TYPE
Axx KEYNOTE
GENERAL FLOOR PLAN NOTES:
REFER TO OVERALL FLOOR PLANS FOR FLOOR PLAN GENERAL NOTES
FINISH FLOOR ELEVATIONS UNLESS NOTED OTHERWISE ARE AS
FOLLOWS:
A. BASEMENT - 88' - 8"
B. FIRST FLOOR - 100' - 0"
C. SECOND FLOOR - 111' - 4"
D. THIRD FLOOR - 122' - 4"
ROOM TAGS FOR DWELLING UNIT BATHROOMS ARE EXCLUDED FROM
THIS DRAWING FOR CLARITY. REFER TO A-015 FOR DWELLING UNIT
ROOM NUMBER LEGEND.
ADDITIONAL PARTITION TAGS AND DIMENSIONS FOR DWELLING UNITS
ARE LOCATED ON DRAWINGS A-401 THRU A-410. REFER TO SHEET
A-015 FOR EACH MODULE TYPE ARRANGEMENTS
1.
2.
3.
4.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
A
B
KEY PLAN
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
N
E W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
Y
F
S
R M
C
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/2
/2
:4
:4
P
M
A-111B
C R
E E
D
B C
H A
P M
A N
C R
E E
D
M A
Y
A
C
E N
T R
A L .R
V T
G R
O U
N D
F L O
O R
P L A
N A
R E
A
B
0 4' 8' 16'SCALE 1/8" = 1'-0"
A6
GROUND FLOOR PLAN AREA - B
N
ARCHITECTURE KEYNOTES
KEYNOTE KEYNOTE DESCRIPTION
A14 WALL MAIL LOCKER SYSTEM (LK-1); SEE FINISH MATERIAL LEGEND
FOR ADDITIONAL INFORMATION.
A15 MAIL DROP SYSTEM (LK-3); SEE FINISH MATERIAL LEGEND FOR
ADDITIONAL INFORMATION.
A16 ELECTRONIC COOKTOP.
A17 RECIRCULATING RANGE HOOD.
A18 MECHANICAL EQUIPMENT. RE: MECHANICAL
A20 PREPARE SURFACE AND PAINT EXISTING METAL RAILING.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/0 /2
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
17 16.918.9
A03
A04
A02
A05
A06
A02A02A02
A01A01
17.918
A20
A26
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
19202122
W04W04
17.918
A20A20
DS
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
21.324.1
W02 W02
W02 W02
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
2526272829
W03
W03
034 033
DS
A-203
E1
A-203
E4
A-203
A1
A-203
A4
GENERAL NOTES: ELEVATIONS
WINDOWS NOT TAGGED ARE WINDOW TYPE W01. REFER TO A-631 FOR
WINDOW SCHEDULE AND A-641 FOR WINDOW DETAILS.
REFER TO A-631 FOR LOUVER SCHEDULE AND A-642 FOR LOUVER
DETAILS.
1.
2.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/2
/2
:4
:4
P
M
A-203
C R
E E
D
B C
H A
P M
A N
R A
L F
A O
U R
I
M A
Y
A
C
E N
T R
A L .R
V T
E X
T E
R
IO
R B
U
IL
D
IN
G E
L E
V A
T
IO
N
W E
S T
SCALE 1/8" = 1'-0"
E1
PARTIAL WEST ELEVATION
SCALE 1/8" = 1'-0"
E4
PARTIAL WEST ELEVATION
SCALE 1/8" = 1'-0"
A1
PARTIAL WEST ELEVATION
SCALE 1/8" = 1'-0"
A4
PARTIAL WEST ELEVATION
0 4' 8' 16' 0 4' 8' 16'
0 4' 8' 16' 0 4' 8' 16'
ARCHITECTURE KEYNOTES
KEYNOTE KEYNOTE DESCRIPTION
A01 THERMALLY BROKEN ALUMINUM WINDOW SYSTEM. NEW METAL
PANNING SHALL MATCH EXISTING PROFILE.
A02 EXISTING LIMESTONE TO REMAIN. REPOINT STONE. REFER TO
SPECIFICATIONS FOR CLEANING REQUIRED
A03 NEW GRADUATED SLATE ROOF SYSTEM.
A04 NEW COPPER GUTTER
A05 EXISTING BRICK TO REMAIN. CLEAN PER SPECIFICATIONS
A06 EXISTING STONE FOUNDATION WALL TO REMAIN. CLEAN PER
SPECIFICATIONS
A20 PREPARE SURFACE AND PAINT EXISTING METAL RAILING.
A26 EXISTING LIMESTONE PARAPET CAPS TO BE REMOVED FOR
INSTALL OF COPPER FLASHING. REFER TO DETAIL A8 ON A-572.
REFER TO SPECIFICATIONS FOR CLEANING REQUIRED
A02A06 A01
A03
A04A02
A05
A26
A05
A02A06
A01
A26
A05
A02 A06A01
A03
A04 A02
TYP
TYP
TYP
TYP
TYP
TYP
TYP TYP
A01
TYP
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/0 /2
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
8.7
A26
A05
A06
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
11.1 12.1
A03
A04
A02
A02A02A02
A01A01
A05
A06
014 013 011012
DS
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
11.1
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
A12
17.9
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
18.9
023022021 026
17.9 18
A20
A25
DS
GROUND FLOOR
100' - 0"
SECOND FLOOR
111' - 4"
ROOF LEVEL
132' - 8"
BASEMENT
88' - 8"
THIRD FLOOR
122' - 8"
21.3
A20
A-206
E1
A-206
E3
A-206
E5 A-206
A1
A-206
A3
A-206
A5
GENERAL NOTES: ELEVATIONS
WINDOWS NOT TAGGED ARE WINDOW TYPE W01. REFER TO A-631 FOR
WINDOW SCHEDULE AND A-641 FOR WINDOW DETAILS.
REFER TO A-631 FOR LOUVER SCHEDULE AND A-642 FOR LOUVER
DETAILS.
1.
2.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/2
/2
:4
:5
P
M
A-206
C R
E E
D
B C
H A
P M
A N
R A
L F
A O
U R
I
M A
Y
A
C
E N
T R
A L .R
V T
E X
T E
R
IO
R B
U
IL
D
IN
G E
L E
V A
T
IO
N
E A
S T
SCALE 1/8" = 1'-0"
E1
PARTIAL EAST ELEVATION
SCALE 1/8" = 1'-0"
E3
PARTIAL EAST ELEVATION
SCALE 1/8" = 1'-0"
E5
PARTIAL EAST ELEVATION
SCALE 1/8" = 1'-0"
A1
PARTIAL EAST ELEVATION
SCALE 1/8" = 1'-0"
A3
PARTIAL EAST ELEVATION
SCALE 1/8" = 1'-0"
A5
PARTIAL EAST ELEVATION
0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16'
0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16'
ARCHITECTURE KEYNOTES
KEYNOTE KEYNOTE DESCRIPTION
A01 THERMALLY BROKEN ALUMINUM WINDOW SYSTEM. NEW METAL
PANNING SHALL MATCH EXISTING PROFILE.
A02 EXISTING LIMESTONE TO REMAIN. REPOINT STONE. REFER TO
SPECIFICATIONS FOR CLEANING REQUIRED
A03 NEW GRADUATED SLATE ROOF SYSTEM.
A04 NEW COPPER GUTTER
A05 EXISTING BRICK TO REMAIN. CLEAN PER SPECIFICATIONS
A06 EXISTING STONE FOUNDATION WALL TO REMAIN. CLEAN PER
SPECIFICATIONS
A12 EXISTING LATTICE FENCE TO BE REFURBISHED AND REINSTALLED.
A20 PREPARE SURFACE AND PAINT EXISTING METAL RAILING.
A25 OVER FLOW DRAIN OUTLET. RE: PLUMBING
A26 EXISTING LIMESTONE PARAPET CAPS TO BE REMOVED FOR
INSTALL OF COPPER FLASHING. REFER TO DETAIL A8 ON A-572.
REFER TO SPECIFICATIONS FOR CLEANING REQUIRED
TYP TYP
A02
A05
A02
A05
A03
A04 A02
A05
A06
A02
A01
TYP
TYP A06
A02
A05
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/0 /2
COUNTER TOP: 1/2"
SOLID SURFACE (SSF-1)
W/ TURNDOWN EDGE
OVER PLYWOOD
WALL
BEYOND
SPRING LOADED
FRAME GUIDE
PARTITION AS
SCHED.
CONCEALED METAL
BRACKETS, ANCHORED
TO 6" BOXED BEAM AT
SILL. ROUTE PLYWOOD
SUCH THAT BRACKET IS
FLUSH. SPACED AS
REQUIRED TO SUPPORT
COUNTER
ALUM WINDOW FRAME
GLAZING (GL-3)
W
IN
D O
W H
E
IG
H T
S
E E
S C
H E
D U
LE
ALUMINUM WINDOW
FRAME
GLAZING (GL-3)
GYP. BD PARTITION.
REFER TO FLOOR PLAN
FOR PARTITION TYPES
ALUMINUM JAMB
FRAME
1/2" GYP. BD AT JAMB
W
IN
D O
W W
ID
T
H
S E
E S
C H
E D
U
LE
CORRIDOR SIDE OFFICE SIDE
GLAZING (GL-3)
ALUMINUM WINDOW
TRACK FRAME
GYP. BD PARTITION. REFER
TO FLOOR PLAN FOR
PARTITION TYPES
METAL CASING BEAD.
TYP. BOTH SIDES
SHIM SPACE
SEALANT, TYPICAL AROUND
WINDOW PERIMETER
J .2
F1
Sim A-641
A1
Sim A-641
E1
Typ.
A-642
CONTINUOUS SEALANT
AROUND PERIMETER,
EACH SIDE
W
IN
D O
W
H
IG
H
T S
E E
S C
H E
D U
LE
5/8" GYPSUM BOARD ON METAL
STUDS WHERE OCCURS - SEE
FLOOR PLANS FOR WALL TYPE
TREATED WOOD SHIM
SPRAY APPLIED CLOSED
CELL POLYURETHANE FOAM
ALUMINUM STOREFRONT
GLAZING - SEE WINDOW
SCHEDULE
SEALANT WITH
BACKER ROD
ALUMINUM PANNING,
PROFILE TO MATCH EXIST.
WOOD BLOCKING
BRICK AS REQUIRED.
800S162-33 & 800T162-33 HEADER
CONTINUOUS SEALANT
AROUND PERIMETER,
EACH SIDE
NEW STONE SILL TO
MATCH EXIST
ALUMINUM STOREFRONT
GLAZING - SEE WINDOW
SCHEDULE
SEALANT WITH
BACKER ROD
ALUMINUM PANNING,
PROFILE TO MATCH EXIST.
WOOD BLOCKING
AIR BARRIER TRANSITION
MEMBRANE WRAPPED INTO
OPENING. SEAL EDGE WITH
LIQUID FLASHING
CONTINUOUS SEALANT
AROUND PERIMETER,
EACH SIDE
W
IN
D O
ID
T H
S E
E S
C H
E D
U
LE
BRICK MASONRY PIER
TO MATCH EXIST.
WINDOWS 5/8" GYPSUM BOARD ON
METAL STUDS WHERE
OCCURS - SEE FLOOR
PLANS FOR WALL TYPE
TREATED WOOD SHIM
SPRAY APPLIED CLOSED
CELL POLYURETHANE FOAM
ALUMINUM STOREFRONT
GLAZING - SEE WINDOW
SCHEDULE
SEALANT WITH
BACKER ROD
ALUMINUM PANNING,
PROFILE TO MATCH EXIST.
WOOD BLOCKING
S H
IM
S
P A
C E
STONE SILL BELOW
ALUMINUM STOREFRONT
GLAZING - SEE WINDOW
SCHEDULE
SOLID SURFACE SILL
BELOW
LAP TRANSITION
MEMNRANE OVER
FLASHING SIDE DAMS. SEAL
EDGES IN LIQUID FLASHING,
TYP. AT OPENINGS
AIR BARRIER
TRANSITION MEMBRANE
V .I.
F
B
R
IC
K
V.I.F
1' - 0" +\-
A
A
SECTION AA
EXISTING MASONRY TO
REMAIN
AIR BARRIER TRANSITION
MEMBRANE
INFILL CAVITY AS REQUIRED
COPPER VENT COVER.
SHALL BE FAUX COVER
WITH SEALED BOX BEHIND.
BACKER ROD AND
SEALANT, TYP. ALL SIDES.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/2
/2
:4
:5
P
M
A-642
C R
E E
D
B C
H A
P M
A N
C R
E E
D
M A
Y
A
C
E N
T R
A L .R
V T
W
IN
D O
W D
E T
A
IL
S
SCALE 1 1/2" = 1'-0"
A8
WINDOW SILL
SCALE 3" = 1'-0"
C8
WINDOW JAMB
SCALE 3" = 1'-0"
F8
WINDOW HEAD
0 3" 6" 9"
0 3" 6" 9"
0 1/2' 1' 1 1/2'
SCALE 1" = 1'-0"
C5
WINDOW SECTION
SCALE 3" = 1'-0"
E1
DETAIL (HEAD/SILL)
SCALE 3" = 1'-0"
B1
DETAIL (JAMB)
0 3" 6" 9"
0 3" 6" 9"
0 1/2' 1' 2'
SCALE 1 1/2" = 1'-0"
A5
VENT COVER DETAIL
0 1/2' 1' 1 1/2'
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/0 /2
GENERAL ROOM FINISH SCHEDULE NOTES:
1. REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR EQUIVALENT
MANUFACTURER TECHNICAL REQUIREMENTS.
2. REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING DRAWINGS, FINISH DRAWINGS,
ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL DRAWINGS FOR ADDITIONAL FINISH
PLACEMENT INFORMATION.
3. REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS, STRUCTURAL DRAWINGS
AND COMMUNICATION DRAWINGS FOR COORDINATION OF BUILDING FINISHES TO
BUILDING SYSTEMS.
4. REFER TO FINISH DRAWINGS FOR PLACEMENT OF FLOOR FINISHES, FLOOR PATTERNS
AND FLOOR MATERIAL CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR
TRANSITIONS BETWEEN ADJOINING FLOORING MATERIALS.
5. REFER TO FINISH DRAWINGS AND INTERIOR ELEVATIONS FOR WALL FINISH EXTENTS,
CORNER GUARD LOCATIONS, AND SIGNAGE.
6. REFER TO REFLECTED CEILING DRAWINGS FOR CEILING HEIGHTS AND CEILING
MATERIAL EXTENTS.
7. REFER TO ENLARGED TOILET DRAWINGS, FINISH PLANS AND INTERIOR ELEVATIONS
FOR PLACEMENT OF INTERIOR FINISHES IN TOILET/LOCKER ROOMS.
8. REFER TO MILLWORK DETAIL DRAWINGS AND INTERIOR ELEVATIONS FOR ASSIGNMENT
OF SOLID SURFACE AND PLASTIC LAMINATE FINISHES AND ADDITIONAL INFORMATION.
9. PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL MOUNTED ITEMS INCLUDING
TOILET FIXTURES, TOILET ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,
COUNTERTOP SUPPORTS, MARKERBOARDS, TACKBOARDS, ACOUSTICAL WALL PANELS
AND ANY OTHER WALL MOUNTED OBJECT.
10. UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL STEEL TO BE PAINTED TO
MATCH ADJACENT FINISH.
11. ALL WINDOW SILLS TO BE SOLID SURFACE (SSF-2).
12. ALL DOOR FRAMES TO BE PAINT (PA-4).
13. ALL METAL FABRICATIONS AND HANDRAILS TO BE PAINT (PA-4).
14. INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
15. ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.
16. WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE TOP OF THE SCHEDULED
WALL BASE.
17. AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL EXPOSED SURFACES.
18. PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS, MISCELLANEOUS STEEL, PIPING,
HANGERS, VALVES AND CONDUITS EXCEPT PRE-FINISHED LINER PANELS. THE PAINT
COLOR SHALL BE AS INDICATED ON SCHEDULE. ALL FIRE PROTECTION PIPING COLOR
SHALL BE SAFETY RED.
19. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED
SUPPORTING EQUIPMENT TO BE PAINTED TO MATCH ADJACENT FINISH UNLESS
OTHERWISE REQUIRED BY CODE. COORDINATE WITH MECHANICAL / ELECTRICAL FOR
FINISHES ON MECHANICAL OR ELECTRICAL EQUIPMENT.
20. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL SURFACES, OPERATING PARTS,
LABELS OR WARNINGS.
21. REFER TO AND COORDINATE WITH FURNITURE DRAWINGS AND TYPICAL MOUNTING
HEIGHTS DRAWING FOR WALL MOUNTING HEIGHTS OF FF&E.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/1
/2
:0
:2
P M
A-652
M O
R S
C H
E L N
T S
P A
R K
S
M .O
R S
C H
E L N
M A
Y
A
C
E N
T R
A L .R
V T
R O
O M
F
IN
IS
H
S C
H E
D U
L E
B
A S
E M
E N
T A
N D
G R
O U
N D
F L O
O R
ROOM FINISH SCHEDULE - BASEMENT AND FIRST FLOOR
ROOM NUMBER ROOM NAME FLOOR BASE WALLS CEILING REMARKS
118 LAUNDRY TLP-1 TLPB-1 PE-1 ACT-2
119 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1 / GYP / PA-1
119A UTILITY RF-1 RB-2 PA-2 EXP / PA-1
119B UTILITY RF-1 RB-2 PA-2 EXP / PA-1
120 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
121 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
122 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1 / GYP / PA-1
122A UTILITY RF-1 RB-2 PA-2 EXP / PA-1
122B UTILITY RF-1 RB-2 PA-2 EXP / PA-1
123 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
124 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1 / GYP / PA-1
125 VESTIBULE WOM-1 / TER-1 TERB-1 PA-2 GYP / PA-1
126 CQ OFFICE RF-1 RB-2 PA-2 ACT-1
127 MAIN LOBBY TER-1 / TER-2 /
WOM-1
TERB-1 PA-2 ACT-1 / GYP / PA-1
128 UTILITY RF-1 RB-2 PA-2 ACT-1
129 MAILBOXES TER-1 TERB-1 PA-2 GYP / PA-1 BUILT-IN MAIL SLOTS
(LK-1) AND MAIL
DROP (LK-3)
130 VENDING RF-1 RB-2 PA-2 ACT-1
131 MAIL RF-1 RB-2 PA-2 ACT-1
132 RECYCLE RF-1 RB-2 PA-2 ACT-1
133 JANITOR TLP-1 TLPB-1 PE-1 / FRP-1 ACT-2 FRP TO 4'-0" AFF
134 TOILET TLP-1 / TLP-2 TLPB-1 TLP-3 / TLP-4 / PE-2 MR GYP / PE-1
135 TOILET TLP-1 / TLP-2 TLPB-1 TLP-3 / TLP-4 / PE-2 MR GYP / PE-1
136 SHARED OFFICE RF-1 RB-1 PA-2 / PA-3 ACT-1
137 PRIVATE OFFICE RF-1 RB-1 PA-2 / PA-3 ACT-1
138 SHARED OFFICE RF-1 RB-1 PA-2 / PA-3 ACT-1
139 PRIVATE OFFICE RF-1 RB-1 PA-2 / PA-3 ACT-1
140 OPEN OFFICE RF-1 / WOM-1 RB-1 PA-2 ACT-1 / GYP / PA-1
141 SUPPLIES RF-1 RB-1 PA-2 ACT-1
142 CONFERENCE RF-1 RB-1 PA-2 / PA-3 ACT-1
143 WELLNESS ROOM RF-1 RB-1 PA-2 ACT-1
144 STORAGE RF-1 RB-1 PA-2 ACT-1
145 BREAK RF-1 RB-1 PA-2 / PA-5 ACT-1 / GYP / PA-1
146 STORAGE RF-1 RB-1 PA-2 ACT-1
147 CORRIDOR RF-1 / WOM-1 RB-1 PA-2 / PA-5 ACT-1 / GYP / PA-1
148 STAIR 5 RFST-1 RB-2 PA-2 ACT-2
149 STAIR 4 RFST-1 RB-2 PA-2 ACT-2
151 STAIR 1 RFST-1 RB-2 PA-2 ACT-2
152 STAIR 3 RFST-1 RB-2 PA-2 ACT-2
154 VESTIBULE WOM-1 RB-1 PA-2 GYP / PA-1
155 STORAGE RF-1 RB-2 PA-2 ACT-1
ROOM FINISH SCHEDULE - BASEMENT AND FIRST FLOOR
ROOM NUMBER ROOM NAME FLOOR BASE WALLS CEILING REMARKS
BASEMENT
001 VESTIBULE CS-1 RB-2 PA-2 EXP / PA-1
002 MECH CS-1 RB-2 PA-2 EXP / PA-1
003 FITNESS RF-2 RB-2 PE-2 / MR-1 GYP / PE-1
004 ELEC CS-1 RB-2 PA-2 GYP / PA-1
005 COMM CS-1 RB-2 PA-2 GYP / PA-1
006 CORRIDOR RF-1 / RFST-1 RB-2 PA-2 GYP / PA-1
007 MENS TOILET / SHOWER TLP-1 / TLP-2 MT-1 TLP-3 / TLP-4 / PE-2 MR GYP / PE-1
008 WOMENS TOILET / SHOWER TLP-1 / TLP-2 MT-1 TLP-3 / TLP-4 / PE-2 MR GYP / PE-1
009 BFP ROOM CS-1 RB-2 PA-2 GYP / PA-1
010 MECH CS-1 RB-2 PA-2 GYP / PA-1
011 FP RM CS-1 RB-2 PA-2 GYP / PA-1
012 MECH CS-1 RB-2 PA-2 GYP / PA-1
013 STORAGE CS-1 RB-2 PA-2 GYP / PA-1
014 STORAGE CS-1 RB-2 PA-2 GYP / PA-1
015 VESTIBULE CS-1 RB-2 PA-2 EXP / PA-1
016 MECH CS-1 RB-2 PA-2 EXP / PA-1
017 EM ELEC CS-1 RB-2 PA-2 GYP / PA-1
018 VESTIBULE CS-1 RB-2 PA-2 GYP / PA-1
019 CORRIDOR CS-1 RB-2 PA-2 GYP / PA-1
GROUND FLOOR
101A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
101B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
101C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
102A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
102B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
102C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
103A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
103B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
103C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
104A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
104B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
104C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
104D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
105A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
105B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
105C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
106A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
106B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
106C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
106D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
107A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
107B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
107C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
107D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
108A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
108B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
108C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
108D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
109A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
109B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
109C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
109D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
110A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
110B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
110C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
110D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
111A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
111B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
111C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
112A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
112B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
112C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
112D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
113A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
113B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
113C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
114A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
114B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
114C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
114D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
115A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
115B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
115C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
116A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
116B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
116C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
117 LAUNDRY TLP-1 TLPB-1 PE-1 ACT-2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/3
/2
GENERAL ROOM FINISH SCHEDULE NOTES:
1. REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR EQUIVALENT
MANUFACTURER TECHNICAL REQUIREMENTS.
2. REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING DRAWINGS, FINISH DRAWINGS,
ENLARGED PLAN DRAWINGS AND INTERIOR DETAIL DRAWINGS FOR ADDITIONAL FINISH
PLACEMENT INFORMATION.
3. REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS, STRUCTURAL DRAWINGS
AND COMMUNICATION DRAWINGS FOR COORDINATION OF BUILDING FINISHES TO
BUILDING SYSTEMS.
4. REFER TO FINISH DRAWINGS FOR PLACEMENT OF FLOOR FINISHES, FLOOR PATTERNS
AND FLOOR MATERIAL CHANGES. REFER TO FLOORING TRANSITION DETAILS FOR
TRANSITIONS BETWEEN ADJOINING FLOORING MATERIALS.
5. REFER TO FINISH DRAWINGS AND INTERIOR ELEVATIONS FOR WALL FINISH EXTENTS,
CORNER GUARD LOCATIONS, AND SIGNAGE.
6. REFER TO REFLECTED CEILING DRAWINGS FOR CEILING HEIGHTS AND CEILING
MATERIAL EXTENTS.
7. REFER TO ENLARGED TOILET DRAWINGS, FINISH PLANS AND INTERIOR ELEVATIONS
FOR PLACEMENT OF INTERIOR FINISHES IN TOILET/LOCKER ROOMS.
8. REFER TO MILLWORK DETAIL DRAWINGS AND INTERIOR ELEVATIONS FOR ASSIGNMENT
OF SOLID SURFACE AND PLASTIC LAMINATE FINISHES AND ADDITIONAL INFORMATION.
9. PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL MOUNTED ITEMS INCLUDING
TOILET FIXTURES, TOILET ACCESSORIES, TOILET PARTITIONS, MILLWORK, SHELVES,
COUNTERTOP SUPPORTS, MARKERBOARDS, TACKBOARDS, ACOUSTICAL WALL PANELS
AND ANY OTHER WALL MOUNTED OBJECT.
10. UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL STEEL TO BE PAINTED TO
MATCH ADJACENT FINISH.
11. ALL WINDOW SILLS TO BE SOLID SURFACE (SSF-2).
12. ALL DOOR FRAMES TO BE PAINT (PA-4).
13. ALL METAL FABRICATIONS AND HANDRAILS TO BE PAINT (PA-4).
14. INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
15. ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.
16. WALL CORNER GUARDS TO BE INSTALLED STARTING AT THE TOP OF THE SCHEDULED
WALL BASE.
17. AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL EXPOSED SURFACES.
18. PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS, MISCELLANEOUS STEEL, PIPING,
HANGERS, VALVES AND CONDUITS EXCEPT PRE-FINISHED LINER PANELS. THE PAINT
COLOR SHALL BE AS INDICATED ON SCHEDULE. ALL FIRE PROTECTION PIPING COLOR
SHALL BE SAFETY RED.
19. ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND ASSOCIATED
SUPPORTING EQUIPMENT TO BE PAINTED TO MATCH ADJACENT FINISH UNLESS
OTHERWISE REQUIRED BY CODE. COORDINATE WITH MECHANICAL / ELECTRICAL FOR
FINISHES ON MECHANICAL OR ELECTRICAL EQUIPMENT.
20. DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL SURFACES, OPERATING PARTS,
LABELS OR WARNINGS.
21. REFER TO AND COORDINATE WITH FURNITURE DRAWINGS AND TYPICAL MOUNTING
HEIGHTS DRAWING FOR WALL MOUNTING HEIGHTS OF FF&E.
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/1
/2
:0
:3
P M
A-653
M O
R S
C H
E L N
T S
P A
R K
S
M .O
R S
C H
E L N
M A
Y
A
C
E N
T R
A L .R
V T
R O
O M
F
IN
IS
H
S C
H E
D U
L E
S
E C
O N
D A
N D
T H
IR
D
F L O
O R
ROOM FINISH SCHEDULE - SECOND AND THIRD FLOOR
ROOM NUMBER ROOM NAME FLOOR BASE WALLS CEILING REMARKS
229A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 GYP / PA-1
229B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
229C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
229E CORRIDOR RF-1 RB-1 PA-2 ACT-1
230A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 GYP / PA-1
230B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
230C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
230E CORRIDOR RF-3 RB-1 PA-2 ACT-1
231A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
231B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
231C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
231D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
232A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
232B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
232C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
233A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
233B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
233C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
233D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
234A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
234B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
234C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
235A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
235B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
235C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
235D BEDROOM RF-3 RB-1 PA-2 / PA-3 GYP / PA-1
236A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
236B BEDROOM RF-3 RB-1 PA-2 / PA-3 GYP / PA-1
236C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
236D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
237A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 GYP / PA-1
237B BEDROOM RF-3 RB-1 PA-2 / PA-3 GYP / PA-1
237C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
237D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
238A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 GYP / PA-1
238B BEDROOM RF-3 RB-1 PA-2 / PA-3 GYP / PA-1
238C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
239 JANITOR TLP-1 TLPB-1 PE-1 / FRP-1 EXP / PA-1 FRP TO 4'-0"
AFF
240 LAUNDRY TLP-1 TLPB-1 PA-2 GYP / PA-1
241 STAIR 3 RFST-1 RB-2 PA-2 ACT-2
242 STAIR 5 RFST-1 RB-2 PA-2 ACT-2
245 ELEC CLOSET RF-1 RB-2 PA-2 ACT-1
246 ELEC CLOSET RF-1 RB-2 PA-2 ACT-1
247 WOMENS TOILET TLP-1 / TLP-2 TLPB-1 TLP-3 / TLP-4 / PE-2 MR GYP / PE-1
248 MENS TOILET TLP-1 / TLP-2 TLPB-1 TLP-3 / TLP-4 / PE-2 MR GYP / PE-1
251 STAIR 1 RFST-1 RB-2 PA-2 ACT-2
THIRD FLOOR
301 OPEN STORAGE RF-1 RB-2 PA-2 ACT-1
310 STAIR 6 RFST-1 RB-2 PA-2 ACT-2
ROOM FINISH SCHEDULE - SECOND AND THIRD FLOOR
ROOM NUMBER ROOM NAME FLOOR BASE WALLS CEILING REMARKS
SECOND FLOOR
201A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
201B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
201C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
202A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
202B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
202C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
203A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
203B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
203C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
204A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
204B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
204C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
204D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
205A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
205B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
205C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
206 LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
206B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
206C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
206D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
207A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
207B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
207C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
207D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
208A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
208B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
208C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
208D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
209A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
209B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
209C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
209D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
210A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
210B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
210C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
210D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
211A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
211B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
211C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
212A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
212B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
212C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
212D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
213A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
213B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
213C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
214A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 / PA-5 ACT-1 / GYP / PA-1
214B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
214C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
214D BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1
215A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
215B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
215C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
216A LIVING ROOM RF-3 RB-1 PA-2 / TLP-5 ACT-1 / GYP / PA-1
216B BEDROOM RF-3 RB-1 PA-2 / PA-3 ACT-1 / GYP / PA-1
216C BATHROOM TLP-1 MT-1 TLP-3 / PE-2 MR GYP / PE-1
217 LAUNDRY TLP-1 TLPB-1 PA-2 ACT-2
218 LAUNDRY TLP-1 TLPB-1 PA-2 ACT-2
219 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
219A UTILITY RF-1 RB-2 PA-2 -
219B UTILITY RF-1 RB-2 PA-2
220 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
221 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
222 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1 / GYP / PA-1
222A UTILITY RF-1 RB-2 PA-2 -
222B UTILITY RF-1 RB-2 PA-2
223 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
224 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1 / GYP / PA-1
225 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1
226 CORRIDOR RF-1 RB-1 PA-5 / CHR-1 / PA-2 ACT-1 / GYP / PA-1
227 RECYCLE RF-1 RB-2 PA-2 ACT-1
228 VENDING RF-1 RB-2 PA-2 ACT-1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/3
/2
D
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/2
/2
:4
:5
P
M
AG002
C R
E E
D
B C
H A
P M
A N
C R
E E
D
M A
Y
A
C
E N
T R
A L .R
V T
A R
C H
IT
E
C T
U R
A L G
E N
E R
A L N
O T
E S
ARCHITECTURAL GENERAL NOTES
29. BRACE PARTITIONS, SUSPENDED CEILINGS, SOFFITS, SUSPENDED ITEMS, ETC.
ONLY TO STRUCTURAL ELEMENTS ABOVE. DO NOT ANCHOR TO ROOF DECK,
PLUMBING / SPRINKLER PIPES, DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR
ELEMENTS.
30. EXTEND ALL FLOORING AND WALL-BASE COMPLETELY INTO RECESSES, UNDER
OPEN COUNTERTOPS, AND BEHIND ALL EQUIPMENT.
31. ALL MATERIALS USED FOR CONSTRUCTION SHALL BE NEW AND UNDAMAGED.
THE CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL WORK SHOWN.
32. THE CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS
RELATED TO THE WORK. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE
ACTUAL CONDITIONS SHALL BE REPORTED TO THE DESIGN PROFESSIONALS FOR
RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
33. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP
DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL
BE REJECTED AND RETURNED TO THE CONTRACTOR.
34. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH
THE WORK WILL BE INSTALLED AND REPORT TO THE CONTRACTOR IN WRITING
ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THE
INSTALLERS WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE
CORRECTED. INSTALLATION SHALL CONSTITUTE ACCEPTANCE OF THE
SUBSTRATE AND/OR CONDITIONS.
35. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE
CONDITIONS OR DIMENSION IS THE SAME OR REPRESENTATIVE FOR SIMILAR
CONDITIONS THROUGHOUT.
36. CONTROL JOINTS (CJ) SHALL BE INSTALLED AT ALL PARTITIONS. CJ AT GYPSUM
PARTITIONS SHALL BE MAXIMUM 30'-0" O.C., CJ AT CONCRETE MASONRY UNIT
PARTITIONS SHALL BE MAXIMUM 20'-0" O.C., UNLESS OTHERWISE NOTED ON
DRAWINGS. REFER TO ELEVATION DRAWINGS FOR EXTERIOR CONTROL JOINT
LOCATIONS. REVIEW CJ LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION.
37. NON-BEARING PARTITIONS SHALL BE ISOLATED FROM THE BUILDING STRUCTURE
TO PREVENT TRANSFER OF BUILDING LOADS FROM THE STRUCTURE TO THE
PARTITIONS.
38. PRIOR TO BEGINNING ANY WORK, NOTIFY OWNER OF ANY EXISTING MATERIALS
OBSERVED TO POSSIBLY CONTAIN ASBESTOS.
39. REMOVE ABANDONED PIPE, DUCTS, CONDUITS, AND EQUIPMENT INCLUDING
THOSE ABOVE ACCESSSIBLE CEILINGS BACK TO THE SOURCE OF SUPPLY WHERE
POSSIBLE. WHERE NOT POSSIBLE CAP, STUB, AND TAG WITH IDENTIFICATION.
PATCH HOLES LEFT BY REMOVAL USING MATERIALS SPECIFIED FOR NEW
CONSTRUCTION.
40. REMOVE EXISTING WORK AS INDICATED AND AS REQUIRED TO ACCOMPLISH NEW
WORK.
41. WHERE EXISTING FINISHED SURFACES ARE CUT SO THAT A SMOOTH TRANSITION
WITH NEW WORK IS NOT POSSIBLE, TERMINATE EXISTING SURFACE ALONG A
STRAIGHT LINE AT A NATURAL LINE OF DIVISION AND MAKE RECOMMENDATION
TO ARCHITECT.
42. PROTECT EXISTING WORK TO REMAIN. PERFORM CUTTING TO ACCOMPLISH
REMOVALS NEATLY AND AS SPECIFIED FOR CUTTING NEW WORK. REPAIR
ADJACENT CONSTRUCTION AND FINISH DAMAGED DURING REMOVAL WORK.
PATCH AS SPECIFIED FOR PATCHING NEW WORK.
43. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXTENT, NATURE, AND
SCOPE OF WORK DESCRIBED IN THE CONTRACT DOCUMENTS AND
COORDINATING WITH THE OWNER OR HIS/HER REPRESENTATIVE THE
INTERFACING OF THE EXISTING BUILDING AND THE WORK SHOWN AND
DESCRIBED IN THESE CONTRACT DOCUMENTS.
44. ALL "EXISTING" INFORMATION ON THE CONTRACT DOCUMENTS HAS BEEN
OBTAINED FROM A PREVIOUS SET OF DRAWINGS, OR FROM FIELD INVESTIGATION
AND SUCH "EXISTING" INFORMATION SHALL BE FIELD VERIFIED BY ALL
CONTRACTORS.
45. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER FOR DESIGNATED
CONSTRUCTION STAGING LOCATIONS, STORAGE AREAS, AND CONSTRUCTION
SEQUENCING.
46. THE PREMISES WILL BE OCCUPIED AT ALL TIMES DURING THE CONSTRUCTION
SCHEDULE. THE CONTRACTOR SHALL COORDINATE WITH THE OWNER
REGARDING ALL INTERRUPTIONS OF UTILITIES, TEMPORARY EXITS, DUST
PARTITIONS, DELIVERIES, AND ALL OTHER JOB REQUIREMENTS.
1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES AND STANDARDS AS
LISTED OR REFERENCED ON LIFE SAFETY PLAN AND LIFE SAFETY CRITERIA OR AS
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
2. THE CONTRACTOR SHALL INCLUDE ALL WORK REQUIRED TO COMPLY WITH ALL
APPLICABLE CODES AND STANDARDS AS LISTED OR REFERENCED ON LIFE
SAFETY PLAN AND LIFE SAFETY CRITERIA OR AS REQUIRED BY THE AUTHORITY
HAVING JURISDICTION.
3. DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND
ELEVATIONS. LARGE SCALE DETAILS OR PLANS SHALL GOVERN OVER SMALL
SCALE DETAILS OR PLANS. DO NOT SCALE DRAWINGS.
4. THE GENERAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL EXIT SIGNS,
EMERGENCY LIGHTING SYSTEMS, ALARM SYSTEMS AND AUTOMATIC SPRINKLER
SYSTEMS AS REQUIRED BY APPLICABLE CODES AND STANDARDS OR AS
REQUIRED BY THE AUTHORITY HAVING JURISDICTION.
5. ALL FLOORS SHALL BE INSPECTED FOR DAMAGE, WARPING OR OTHER
NOTICEABLE DEVIATIONS AND PATCHED AND LEVELED PRIOR TO COVERING WITH
FLOOR FINISHES, INSTALLATION OF ACCESS FLOOR SYSTEM, OR ERECTION AND
INSTALLATION OF COLD-FORMED FRAMING.
6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL
MANUFACTURER'S RECOMMENDED MAINTENANCE PROCEDURES AND
SCHEDULES.
7. ANY MANUFACTURER'S OR BRAND NAME PRODUCTS INDICATED OR SPECIFIED
ARE DONE SO TO ESTABLISH A MINIMUM LEVEL OF QUALITY.
8. ALL CONSTRUCTION SHALL MEET OR EXCEED LOCAL INDUSTRY STANDARDS.
DETAILS ARE PROVIDED TO INDICATE MINIMUM QUALITY AND TO GIVE
STANDARDS OF CONSTRUCTION. IF A CONDITION IS NOT SPECIFICALLY
DETAILED, SUBMIT A SIMILAR DETAIL FOR GUIDE AND APPROVAL.
9. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS, SECTIONS OR
ELEVATIONS.
10. PROVIDE PRESERVATIVE-TREATED WOOD AT ALL LOCATIONS WHERE WOOD IS IN
DIRECT CONTACT WITH CONCRETE OR MASONRY.
11. PROVIDE 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING AT ALL ELECTRICAL,
PHONE, AND SECURITY SYSTEM PANELS.
12. PROVIDE FIRE-RESISTANT TREATED WOOD BLOCKING FOR SECURE ANCHORAGE
OF ALL SHELVES, RUNNING TRIM, RAILINGS, SUSPENDED ITEMS, DOOR-STOPS,
GRAB-BARS, AND OTHER SIMILAR WOODWORK, HARDWARE, SPECIALTIES,
ACCESSORIES, FIXTURES, OR EQUIPMENT.
13. PROVIDE CEMENT BOARD SHEATHING AT ALL AREAS WHERE A TILE SURFACE IS
TO BE INSTALLED ON METAL STUD WALLS.
14. PROVIDE WATER-RESISTANT GYPSUM BOARD AT ALL WET OR UNCONDITIONED
AREAS INCLUDING, BUT NOT LIMITED TO, PARTITIONS BEHIND SINKS.
CONTRACTOR TO INSURE THAT FIRE RATING IS MAINTAINED.
15. PAINT, STAIN, OR COAT ALL EXPOSED SURFACES OF CONSTRUCTION UNLESS
NOTED OTHERWISE OR IF SURFACES ARE PRE-FINISHED.
16. ALL OPENING DIMENSIONS ARE NOMINAL. THE CONTRACTOR SHALL FIELD
MEASURE ALL OPENINGS AND COORDINATE WITH THE APPROPRIATE SUPPLIER
FOR ALL DOORS AND WINDOWS.
17. ALL CONDUITS, PLUMBING, PIPING, DUCTWORK, AND OTHER EQUIPMENT
EXPOSED TO VIEW SHALL BE LOCATED PARALLEL OR PERPENDICULAR TO THE
STRUCTURAL FRAMING SYSTEM.
18. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS, WHERE
REQUIRED.
19. CERAMIC TILE TO BE INSTALLED UP TO 4'-0" ABOVE FINISH FLOOR AND 1'-0" TO
EITHER SIDE AT ALL MOP SINK LOCATIONS. EXTENT OF TILE VARIES BY
LOCATION.
20. ARCHITECTURAL DETAILS ARE APPLICABLE WHERE INDICATED BY SECTION CUT,
BY NOTE, OR BY DETAIL TITLE. INCORPORATE SIMILAR DETAILS AT SIMILAR
CONDITIONS UNLESS NOTED OTHERWISE. THE CONTRACTOR MAY REQUEST A
CLARIFICATION IF REQUIRED, OTHERWISE THE MORE STRINGENT REQUIREMENTS
SHALL CONTROL.
21. PROVIDE FIRE-STOPPING SYSTEMS AT TOP OF AND AT ALL PENETRATIONS
THROUGH FIRE-RATED PARTITIONS.
22. SEAL ALL EXTERIOR BUILDING JOINTS AT BOTH THE EXTERIOR AND INTERIOR
SURFACES AGAINST MOISTURE AND AIR INFILTRATION.
23. SEAL AROUND ALL DOOR AND WINDOW FRAMES, COUNTERTOPS, WALL-MOUNTED
FIXTURES AND EQUIPMENT TO ADJACENT WALL SURFACES.
24. THE CONTRACTOR SHALL REVIEW THE DIMENSIONS OF ALL EQUIPMENT IN THE
PROJECT REGARDLESS OF THE SOURCE AND COORDINATE ACCESS TO THE
SPACE AND VERIFY CLEAR FLOOR SPACE IS PROVIDED AS REQUIRED TO ENSURE
EASE OF INSTALLATION.
25. ALL WORK MUST BE OF GOOD QUALITY, FREE FROM DEFECTS, AND IN
ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
26. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL
PENETRATIONS IN THE STRUCTURE FOR THE PROPER INSTALLATION OF THE
WORK. REFER TO STRUCTURAL DRAWINGS FOR SECONDARY FRAMING AND OR
REINFORCING REQUIRED AT PENETRATIONS IN STEEL, CONCRETE OR MASONRY.
27. THE CONTRACTOR SHALL PROVIDE ACCESS DOORS OR PANELS AS REQUIRED
FOR SERVICING OF PIPING, DUCTWORK, CABLE TRAYS, FIRE DAMPERS AND
SIMILAR APPLICATIONS. ALL PROPOSED ACCESS DOOR LOCATIONS TO BE
SUBMITTED FOR APPROVAL PRIOR TO INSTALLATION.
28. PROVIDE ALL HVAC, PLUMBING, GAS OR ELECTRIC SERVICE CONNECTIONS TO
CASEWORK, FIXTURES, SIGNAGE, OR EQUIPMENT INDICATED (WHETHER UNITS
ARE INSTALLED BY CONTRACTOR OR BY OTHERS).
ARCHITECTURAL SPECIFIC WORK QUANTITIES FOR BIDDING PURPOSES
QUANTITIES LISTED BELOW ARE INITIAL ESTIMATES BASED ON LIMITED VISUAL INSPECTIONS. THE QUANTITIES SHALL BE USED FOR BIDDING PURPOSES AND WILL BE BASIS FOR REVIEW OF MODIFICATIONS REQUIRED DURING CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR DETERMINATION EXTENT
OF WORK REQUIRED FOR EACH TYPE OF WORK NOTED BELOW.
DEMOLITION SCOPE ITEMS
REMOVAL OF WOOD SUBFLOOR
REMOVAL OF WOOD ROOF DECK
12,000 SF
1,700 SF
QUANTITYNEW WORK SCOPE ITEMS
NEW PLYWOOD SUBFLOOR
NEW ROOF SHEATHING
INSTALLATION OF SELF-LEVELING COMPOUND TO
CORRECT DAMAGED / OUT OF LEVEL SUBFLOOR
REPOINT EXTERIOR BRICK WALL
CLEAN BRICK
REPLACE BRICK
QUANTITY
12,000 SF
1,700 SF
17,000 SF
16,000 SF (WALL SURFACE AREA)
16,000 SF
4,000 SF
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/0 /2
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/3
/2
:3
:4
A
M
EP603
P K
A N
G
T M
O R
G A
N
D G
IG
L
IO
M A
Y
E
C
E N
T R
A L
P A
N E
L B
O A
R D
S C
H E
D U
L E
S
PANELBOARD KEY
20L1-1-SEC1 20L1-1-SEC2
20L1-2-SEC1 20L1-2-SEC2
DEMAND WITH EXPANSION: 111 A
TOTAL ESTIMATED DEMAND... 93 A
TOTAL CONNECTED CURRENT: 119 A
TOTAL ESTIMATED DEMAND LOAD: 33412 VA
TOTAL CONNECTED LOAD: 42764 VA
PANEL TOTALS
TOTAL LOAD: 13720 VA 15704 VA 13340 VA
41 20 1 Spare 0 0 -- -- -- -- 42
39 20 1 Receptacle BEDROOM 114D 2#12, 1#12G - 3/4"C 1260 0 -- -- -- -- 40
37 20 1 Receptacle MICROWAVE 116A 2#12, 1#12G - 3/4"C 1000 0 4#10, 1#10G - 3/4"C SPD 3 30 38
35 30 1 Receptacle COOKTOP 116A 2#10, 1#10G - 3/4"C 2400 1000 2#12, 1#12G - 3/4"C Receptacle MICROWAVE 114A 1 20 36
33 20 1 Receptacle LIVING ROOM 116A 2#12, 1#12G - 3/4"C 360 1800 2#12, 1#12G - 3/4"C Receptacle COOKTOP 114A 1 20 34
31 20 1 Receptacle LIVING ROOM 116A 2#12, 1#12G - 3/4"C 360 360 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 114A 1 20 32
29 20 1 Receptacle BEDROOM 116B 2#12, 1#12G - 3/4"C 1260 360 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 114A 1 20 30
27 20 1 Receptacle MICROWAVE 113A 2#12, 1#12G - 3/4"C 1000 1260 2#12, 1#12G - 3/4"C Receptacle BEDROOM 114B 1 20 28
25 20 1 Receptacle LIVING ROOM 113A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 113A 1 30 26
23 20 1 Receptacle LIVING ROOM 113A 2#12, 1#12G - 3/4"C 360 1260 2#12, 1#12G - 3/4"C Receptacle BEDROOM 113B 1 20 24
21 20 1 Receptacle MICROWAVE 111A 2#12, 1#12G - 3/4"C 1000 1440 2#12, 1#12G - 3/4"C Receptacle BEDROOM 111B 1 20 22
19 20 1 Receptacle LIVING ROOM 111A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 111A 1 30 20
17 30 1 Receptacle COOKTOP 112A 2#10, 1#10G - 3/4"C 2400 360 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 111A 1 20 18
15 20 1 Receptacle LIVING ROOM 112A 2#12, 1#12G - 3/4"C 360 1000 2#12, 1#12G - 3/4"C Receptacle MICROWAVE 112A 1 20 16
13 20 1 Receptacle BEDROOM 112D 2#12, 1#12G - 3/4"C 1260 540 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 112A 1 20 14
11 20 1 Receptacle MICROWAVE 115A 2#12, 1#12G - 3/4"C 1000 1080 2#12, 1#12G - 3/4"C Receptacle BEDROOM 112B 1 20 12
9 20 1 Receptacle LIVING ROOM 115A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 115A 1 30 10
7 20 1 Receptacle BEDROOM 109B 2#12, 1#12G - 3/4"C 1440 1260 2#12, 1#12G - 3/4"C Receptacle BEDROOM 115B 1 20 8
5 20 1 Receptacle - Microwave - 109A 2#12, 1#12G - 3/4"C 1500 360 2#12, 1#12G - 3/4"C Receptacle BATHROOM 115C 1 20 6
3 20 1 Refrig., AC Recept., Range Hood - 109A 2#12, 1#12G - 3/4"C 1064 2400 2#10, 1#10G - 3/4"C Cooktop 109A 1 30 4
1 20 1 Receptacle BEDROOM 109D 2#12, 1#12G - 3/4"C 1440 540 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 109A 1 20 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B C WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
NOTES:
ENCLOSURE: Type 1 MCB RATING: 225 A
MOUNTING: Surface WIRES: 4 MAINS RATING: 225 A
SUPPLY FROM: DPL PHASE: 3 MAINS TYPE: MCB
LOCATION: UTILITY 122B VOLTAGE: 208Y/120V A.I.C. RATING: 10000
PANELBOARD: 20L1-1-S1
DEMAND WITH EXPANSION: 94 A
TOTAL ESTIMATED DEMAND... 78 A
TOTAL CONNECTED CURRENT: 95 A
TOTAL ESTIMATED DEMAND LOAD: 28175 VA
TOTAL CONNECTED LOAD: 34047 VA
PANEL TOTALS
TOTAL LOAD: 11974 VA 12657 VA 9416 VA
41 -- -- Space -- 0 0 -- Space -- -- 42
39 -- -- Space -- 0 0 -- Space -- -- 40
37 -- -- Space -- 0 0 Space 1 20 38
35 -- -- Space -- 0 0 -- Space -- -- 36
33 -- -- Space -- 0 0 -- Space -- -- 34
31 -- -- -- -- 3333 0 -- Space -- -- 32
29 -- -- -- -- 3333 0 Spare 1 20 30
27 50 3 Receptacle - Maintenance - Corridor 122 3#6, 1#10G - 1"C 3333 0 Spare 1 20 28
25 20 1 Receptacle BEDROOM 110D 2#12, 1#12G - 3/4"C 1260 0 Spare 1 20 26
23 20 1 Receptacle MICROWAVE 110A 2#12, 1#12G - 3/4"C 1000 0 Spare 1 20 24
21 30 1 Receptacle COOKTOP 110A 2#10, 1#10G - 3/4"C 2400 0 Spare 1 20 22
19 20 1 Receptacle LIVING ROOM 110A 2#12, 1#12G - 3/4"C 360 363 2#12, 1#12G - 3/4"C Lighting Room 124, 122, 123, 117 1 20 20
17 20 1 Receptacle LIVING ROOM 110A 2#12, 1#12G - 3/4"C 360 435 2#12, 1#12G - 3/4"C Lighting BEDROOM 116B 1 20 18
15 20 1 Receptacle BEDROOM 110B 2#12, 1#12G - 3/4"C 1260 780 2#12, 1#12G - 3/4"C Lighting BEDROOM 109B 1 20 16
13 20 1 Receptacle 2#12, 1#12G - 3/4"C 180 360 2#12, 1#12G - 3/4"C Receptacle Room 122B, 122A 1 20 14
11 20 1 Washer 117 2#12, 1#12G - 3/4"C 1000 720 2#12, 1#12G - 3/4"C Receptacle Room 124, 122 1 20 12
9 20 1 Washer 117 2#12, 1#12G - 3/4"C 1000 1183 2#12, 1#12G - 3/4"C FCU - Rooms 111A, 112A, 112B, 112D, 123 1 20 10
7 -- -- -- -- 1440 1858 2#12, 1#12G - 3/4"C FCU Room 114B, 110D, 110A, 110B 1 20 8
5 30 2 Dryer 117 2#10, 1#10G - 3/4"C 1440 1128 2#12, 1#12G - 3/4"C VFCU - Corridor 123, 124; CUH - Stair 152 1 20 6
3 -- -- -- -- 1440 1260 2#12, 1#12G - 3/4"C FCU Room 109B, 109A, 109D 1 20 4
1 30 2 Dryer 117 2#10, 1#10G - 3/4"C 1440 1380 2#12, 1#12G - 3/4"C FCU - Room 116A, 115A, 113A, 114D, 114A 1 20 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B C WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
NOTES:
ENCLOSURE: Type 1
MOUNTING: Surface WIRES: 4 MAINS RATING: 225 A
SUPPLY FROM: DPL PHASE: 3 MAINS TYPE: MLO
LOCATION: UTILITY 122B VOLTAGE: 208Y/120V A.I.C. RATING: 10000
PANELBOARD: 20L1-1-S2
DEMAND WITH EXPANSION: 140 A
TOTAL ESTIMATED DEMAND... 117 A
TOTAL CONNECTED CURRENT: 117 A
TOTAL ESTIMATED DEMAND LOAD: 42160 VA
TOTAL CONNECTED LOAD: 42160 VA
PANEL TOTALS
TOTAL LOAD: 14980 VA 14340 VA 12840 VA
41 20 1 Spare 2#12, 1#12G - 3/4"C 0 0 Spare 1 20 42
39 20 1 Spare 2#12, 1#12G - 3/4"C 0 0 Spare 1 20 40
37 20 1 Receptacle MICROWAVE 102A 2#12, 1#12G - 3/4"C 1000 1260 2#12, 1#12G - 3/4"C Receptacle BEDROOM 104D 1 20 38
35 30 1 Receptacle COOKTOP 102A 2#10, 1#10G - 3/4"C 2400 1000 2#12, 1#12G - 3/4"C Receptacle MICROWAVE 104A 1 20 36
33 20 1 Receptacle LIVING ROOM 102A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 104A 1 30 34
31 20 1 Receptacle LIVING ROOM 102A 2#12, 1#12G - 3/4"C 360 360 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 104A 1 20 32
29 20 1 Receptacle BEDROOM 102B 2#12, 1#12G - 3/4"C 1260 360 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 104A 1 20 30
27 20 1 Receptacle LIVING ROOM 103A 2#12, 1#12G - 3/4"C 1000 1260 2#12, 1#12G - 3/4"C Receptacle BEDROOM 104B 1 20 28
25 20 1 Receptacle MICROWAVE 103A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 103A 1 30 26
23 20 1 Receptacle LIVING ROOM 103A 2#12, 1#12G - 3/4"C 360 1260 2#12, 1#12G - 3/4"C Receptacle BEDROOM 103B 1 20 24
21 20 1 Receptacle MICROWAVE 105A 2#12, 1#12G - 3/4"C 1000 1440 2#12, 1#12G - 3/4"C Receptacle BEDROOM 105B 1 20 22
19 20 1 Receptacle LIVING ROOM 105A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 105A 1 30 20
17 30 1 Receptacle COOKTOP 106A 2#12, 1#12G - 3/4"C 2400 360 2#12, 1#12G - 3/4"C Receptacle BATHROOM 105C 1 20 18
15 20 1 Receptacle LIVING ROOM 106A 2#12, 1#12G - 3/4"C 360 1000 2#12, 1#12G - 3/4"C Receptacle MICROWAVE 106A 1 20 16
13 20 1 Receptacle BEDROOM 106D 2#12, 1#12G - 3/4"C 1260 540 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 106A 1 20 14
11 20 1 Receptacle MICROWAVE 101A 2#12, 1#12G - 3/4"C 1000 1080 2#12, 1#12G - 3/4"C Receptacle BEDROOM 106B 1 20 12
9 20 1 Receptacle LIVING ROOM 101A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 101A 1 30 10
7 20 1 Receptacle BEDROOM 107B 2#12, 1#12G - 3/4"C 1440 1260 2#12, 1#12G - 3/4"C Receptacle BEDROOM 101B 1 20 8
5 20 1 Receptacle MICROWAVE 107A 2#12, 1#12G - 3/4"C 1000 360 2#12, 1#12G - 3/4"C Receptacle BATHROOM 101C 1 20 6
3 20 1 Receptacle LIVING ROOM 107A 2#12, 1#12G - 3/4"C 360 2400 2#10, 1#10G - 3/4"C Receptacle COOKTOP 107A 1 30 4
1 20 1 Receptacle BEDROOM 107D 2#12, 1#12G - 3/4"C 1440 540 2#12, 1#12G - 3/4"C Receptacle LIVING ROOM 107A 1 20 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B C WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
NOTES:
ENCLOSURE: Type 1 MCB RATING: 225 A
MOUNTING: Surface WIRES: 4 MAINS RATING: 225 A
SUPPLY FROM: DPL PHASE: 3 MAINS TYPE: MCB
LOCATION: UTILITY 119B VOLTAGE: 208Y/120V A.I.C. RATING: 10000
PANELBOARD: 20L1-2-S1
DEMAND WITH EXPANSION: 116 A
TOTAL ESTIMATED DEMAND... 96 A
TOTAL CONNECTED CURRENT: 117 A
TOTAL ESTIMATED DEMAND LOAD: 34679 VA
TOTAL CONNECTED LOAD: 42216 VA
PANEL TOTALS
TOTAL LOAD: 16284 VA 14646 VA 11287 VA
41 -- -- Space -- 0 0 -- Space -- -- 42
39 -- -- Space -- 0 0 -- Space -- -- 40
37 -- -- Space -- 0 0 -- Space -- -- 38
35 20 1 Spare 0 0 Spare 1 20 36
33 20 1 Spare 0 0 Spare 1 20 34
31 20 1 Spare 0 3333 -- -- -- -- 32
29 20 1 Spare 0 3333 -- -- -- -- 30
27 20 1 CUH-151-1 Stair, VFCU-119-1, 121-1 Corr. 2#12, 1#12G - 3/4"C 1128 3333 3#6, 1#10G - 1"C Receptacle - Maintenance - Corr. 119 3 50 28
25 20 1 Receptacle BEDROOM 110D 2#12, 1#12G - 3/4"C 1200 1976 -- -- -- -- 26
23 20 1 Receptacle MICROWAVE 110A 2#12, 1#12G - 3/4"C 1000 1976 2#10, 1#10G - 3/4"C CU-02 - Exterior - AREA C 2 30 24
21 30 1 Receptacle COOKTOP 110A 2#10, 1#10G - 3/4"C 2400 1976 -- -- -- -- 22
19 20 1 Receptacle LIVING ROOM 110A 2#12, 1#12G - 3/4"C 360 1976 2#10, 1#10G - 3/4"C CU-02 - Exterior - AREA C 2 30 20
17 20 1 Receptacle LIVING ROOM 110A 2#12, 1#12G - 3/4"C 360 363 2#12, 1#12G - 3/4"C Lighting Corridor 119, 120, 121 1 20 18
15 20 1 Receptacle BEDROOM 110B 2#12, 1#12G - 3/4"C 1260 445 2#12, 1#12G - 3/4"C Lighting Bedroom 110, 114, 116 1 20 16
13 20 1 Receptacle UTILITY 119B 2#12, 1#12G - 3/4"C 180 675 2#12, 1#12G - 3/4"C Lighting Bedroom 109, 111, 112, 113, 115 1 20 14
11 20 1 Washer 118 2#12, 1#12G - 3/4"C 1000 180 2#12, 1#12G - 3/4"C Receptacle 1 20 12
9 20 1 Washer 118 2#12, 1#12G - 3/4"C 1000 900 2#12, 1#12G - 3/4"C Receptacle - Corridor 119,121 1 20 10
7 -- -- -- -- 1440 2100 2#12, 1#12G - 3/4"C FCU - Rooms 105, 107 1 20 8
5 30 2 Dryer 118 2#10, 1#10G - 3/4"C 1440 1634 2#12, 1#12G - 3/4"C FCU - Rooms 102, 104 & CUH Stair 151 1 20 6
3 -- -- -- -- 1440 763 2#12, 1#12G - 3/4"C FCU - Rooms 101, 103, 105 1 20 4
1 30 2 Dryer 118 2#10, 1#10G - 3/4"C 1440 1603 2#12, 1#12G - 3/4"C FCU - Bedroom 104, 108 1 20 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B C WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
NOTES:
ENCLOSURE: Type 1
MOUNTING: Surface WIRES: 4 MAINS RATING: 225 A
SUPPLY FROM: DPL PHASE: 3 MAINS TYPE: MLO
LOCATION: UTILITY 119B VOLTAGE: 208Y/120V A.I.C. RATING: 10000
PANELBOARD: 20L1-2-S2
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
R
E A
D Y
T O
A D
V E
R T
IS
E
M A
Y
A
M E
N D
M E
N T
/0
/2
S
IG
N E
D B
Y
D R
A W
N B
Y
C H
E C
K E
D B
Y
F
IL
E N
A M
E
S
IZ
E
P L O
T S
C A
L E
IS
S
U E
D A
T E
P R
O J E
C T
N O
C O
N T
R A
C T
N O
X
S O
L
IC
IT
A
T
IO
N N
O
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
W
Y O
R K
D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K N
Y
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
1 753
A
B
C
D
SHEET ID
READY TO ADVERTISE
2 864 10
E
F
G
W E
S T
P O
IN
T
N
Y W
E S
T P
O
IN
T B
U
IL
D
IN
G
R
E P
A
IR
U S
A G
W E
S T
P O
IN
T
S
R M
A S
I N
D
IC
A T
E D
W D
S -1
-D
US Army Corps of Engineers ®
P N
O
/3
/2
:3
:4
A
M
EP604
P K
A N
G
T M
O R
G A
N
D G
IG
L
IO
M A
Y
E
C
E N
T R
A L
P A
N E
L B
O A
R D
S C
H E
D U
L E
S
DEMAND WITH EXPANSION: 138 A
TOTAL ESTIMATED DEMAND... 115 A
TOTAL CONNECTED CURRENT: 115 A
TOTAL ESTIMATED DEMAND LOAD: 41560 VA
TOTAL CONNECTED LOAD: 41560 VA
PANEL TOTALS
TOTAL LOAD: 13720 VA 15000 VA 12840 VA
41 20 1 Spare 0 0 -- -- -- -- 42
39 20 1 Receptacle BEDROOM 214D 2#12, 1#12G - 3/4"C 1260 0 -- -- -- -- 40
37 20 1 Receptacle MICROWAVE 216A 2#12, 1#12G - 3/4"C 1000 0 4#10, 1#10G - 3/4"C SPD 3 30 38
35 30 1 Receptacle COOKTOP 216A 2#10, 1#10G - 3/4"C 2400 1000 2#12, 1#12G - 3/4"C Receptacle MICROWAVE 214A 1 20 36
33 20 1 Receptacle LIVING ROOM 216A…
This is the start of the file's text. The full file is on GovTribe.