License & Permit No. 8393 140 Eleventh St. Piscataway, NJ 08854
Tel: (732) 968-9400 Fax: (732) 968-8880
Newark Riverfront Park Phase C
City of Newark, New Jersey
Item: XBE-1 FAI-GON #6
Approved As Submitted
By: Frank De Sousa
Date: 3/21/2019
Section:265619
Newark Riverfront Park Phase C Submittal # 265619-2.0 (#548.0) Spec. Section # 265619-1.4 & 1.5
XBE-1 & -1A GUARDRAIL LED LIGHTING SUBMITTAL/SHOP DRAWING
Vendor-Sub: Fai-Gon Electrical Contractors Submitted by: Tomco Construction Inc.
Date: 3/27/2019
Compatible LED Drivers or Modules
Typical DC input Voltage to Module ……………………………………..………………………….….…………………………… 12VDC
Ratings and Performance Specifications Nominal DC Power Consumption ………………..…………………………………….…………….……...................... See Table 1 Recommended Screw Installation Torque …………………………………………………………….….…. 75 inch ounces Maximum Operating Range Ambient Temperature (Ta) ………………………….….……..….….. -40 to +50°C Maximum Solder Pad Temperature (Ts) …………………………………………….…….………………………...….………. +105°C Estimated Lumen Depreciation (TM-21) ….………….…70% initial lumens (L70) @ 100,000 hours Nominal Weight ……………………………………………………………………….…………………….…………………….……………..… 10 grams Safety/Compliance UL Class 2 Recognized Component............................................................... E321468
Application Notes
1. ThermAdjust™ technology automatically reduces LED current to maintain solder pad temperatures below the maximum solder pad temperature (Ts). This ensures longer LED lifetime and is ideal for luminaires that have the potential to be placed in environments with elevated ambient temperatures.
2. The use of any washer (lock, flat, etc.) will void the warranty due to possible damage and/or shorting to the circuit board.
3. This module requires a heat sink at full power for maximum performance. Care should be taken in the luminaire designs to allow heat to escape the system. Contact factory for thermal guidelines.
4. Abnormal operating conditions such as elevated ambient temperatures can be expected to negatively impact lumen output, product lifetime and/or performance.
Small ThermAdjustTM Module For a Variety of Applications
Features & Benefits
Constant voltage 12VDC input design allows paralleling of any number of modules up to the maximum wattage of driver Patent pending Thermadjust™ temperature compensation technology provides “fool proof” thermal management Latest generation LED for high efficacy and color consistency Patented intelligent thermal design FR4 core board with heavy copper Includes mounting holes and high performance adhesive transfer tape for mechanical attachment Reverse polarity protection and pre-wired leads Protective conformal (transparent) coating for additional protection in exterior applications
B B
B A
S eries
January 2019, Rev. H 14331 Chambers Road, Tustin CA 92780 714.508.0729 customerservice@permlight.com
B B
B A
S eries
Table 1, Performance Characteristics at 25C Data from laboratory test measurements, actual results may vary.
Options available Other CCT and CRI may be available on special order 90CRI minimum versions on special order, subtract 15% lumens
Packaging Product is marked with SKU and lot information on non-LED side of module.
Sold in groups of (85) unit(s) and packaged in ESD bags with SKU and lot information.
Warranty 5-Year limited warranty in accordance with published warranty conditions. Product must be used with compatible components (modules, drivers, engines and/or accessories) and no maximum ratings (such as Ts) shall be exceeded during any expected operating conditions of the system. If product is used with other manufacturer’s product, compatibility must be recognized in writing by Permlight Technologies.
Permlight Technologies owns the following United States patents of which one or more may be applicable to the design and/or manufacture of this product: 6712486, 6578986, 6846093, 7114831, 7306353, 7102172, 7108396, 7329024, 7387406, 7582911, 7649327, 8926145, 8729810. Additional granted patents, patents pending and other IP protection rights may apply.
Part Number
Nominal
CCT
(Kelvin) Minimum
CRI
Nominal Light Output
@ 12VDC
(Lumens)
Nominal Power
Consumption
@ 12VDC
(WDC)
Nominal Module Efficacy
@12VDC
(DC LPW)
BB09BA-27-80-01 2700 80 303 3.06 99
BB09BA-30-80-01 3000 80 316 3.06 103
BB09BA-35-80-01 3500 80 325 3.06 106
BB09BA-40-80-01 4000 80 330 3.06 108
BB09BA-50-80-01 5000 80 360 3.06 118
14331 Chambers Road, Tustin CA 92780 714.508.0729 customerservice@permlight.com
Physical Dimensions
Site Access:
1. Traffic plan
2. MT120 form – Application for highway occupancy (PDF attachment)
3. Final temporary easement plan (PDF attachment - KMZ file)
D
G20-2A
G20-2A
Lane
Lane
Shoulder
Shoulder
Lane
Lane B
S S S S S S
D
D
D
D
DDDDDDD
D
D
D
D
VARIESBUFFER
L/3
Lane
Lane
Shoulder
Shoulder
Lane
Lane
MedianMedian S S S S S S
W4-2 (S)
L
L/3L/3L/3
B
W4-2 (S)
W20-1D W20-1D
W20-1DW20-1D
W20-5A
W20-5A
W20-5B
W20-5B
NOTES:
G20-2A
Shoulder
Lane
Lane
Shoulder
G20-2A
Lane
Lane
D
D
D
DD
D
D
D
DDDDDDDD
D
S S S
Lane
S S
L/3
BUFFER VARIES
Lane
Lane
Lane
Shoulder
Shoulder
Median MedianS S S
S
S S
B
W20-1D W20-1D
W20-1DW20-1D
W20-1A
W20-1A
W20-10C
W20-10C
TCD-14
100’
48" x 48" 48" x 48" 48" x 48" 48" x 48" 48" x 24"
500’ 100’ 500’
48" x 24"48" x 48" 48" x 48" 48" x 48" 48" x 48"
48" x 48" 48" x 48" 48" x 48" 48" x 48" 48" x 48" 48" x 24"
48" x 24"
500’
W1-6, 48" x 24" (3)
48" x 48" 48" x 48" 48" x 48" 48" x 48" 48" x 48"
500’ 500’ 500’
4 & 6 LANES, DIVIDED, SHOULDER CLOSING
4 & 6 LANES, DIVIDED, RIGHT LANE & SHOULDER CLOSING
NEW JERSEY DEPARTMENT OF TRANSPORTATION
TRAFFIC CONTROL DETAILS
1.
2.
100’
MIN.
N.T.S.
ROAD
WORK
1 MILE
ROAD
WORK
1500 FT
SHOULDER
CLOSED
500 FT
ROAD
WORK
1 MILE
ROAD
WORK
1500 FT
SHOULDER
CLOSED
500 FT
ROAD
WORK
1 MILE
RIGHT LANE
CLOSED
1500 FT
RIGHT LANE
CLOSED
1000 FT
ROAD
WORK
1 MILE
RIGHT LANE
CLOSED
1500 FT
RIGHT LANE
CLOSED
1000 FT
ROAD
WORK
�MILE
ROAD
WORK
�MILE
ROAD
WORK
�MILE
ROAD
WORK
�MILE
T P
X O
H A
S
E P
N j d o t p r j w s v s y s t e m
N
J D
O T
W S
P r o j e c t s N
J D
O T
E
ID
d a t e p e n t a b l e s c a l e file=
SEE RECOMMENDED TAPER LENGTH AND
SPACING TABLE ON SHEET TCD-2 FOR
VALUES OF L, B AND D.
IF MEDIAN IS NARROWER THAN WIDTH OF
SIGN PLUS 2 FEET, OMIT MEDIAN SIGNING.
END
ROAD WORK
END
ROAD WORK
END
ROAD WORK
END
ROAD WORK
WORK
AREA
100’
MIN.
WORK
AREA2640’ 1140’
2640’ 1140’
1000’
THIS SIGN SHALL BE INSTALLED FOR ROADS WITH
A SPEED LIMIT OF 45 M.P.H. OR GREATER UNLESS
OTHERWISE DIRECTED BY THE RE.
FOR ROADS WITH A SPEED LIMIT GREATER THAN
55 M.P.H., A "ROAD WORK 2 MILES" SIGN SHALL
ALSO BE INSTALLED 2 MILES IN ADVANCE OF
LANE CLOSING UNLESS OTHERWISE DIRECTED BY
THE RE.
B D
C D
-0
O R
IG
IN
A L
S H
E E
T