Appendix B (Pages 491-624) - Installation and Building Maps-4 - Amendment 2

View the file

Other files

File Type Posted
W912DS18R0011_Amendment_8.pdf PDF
W912DS18R0011_Amendment_7.pdf PDF
W912DS18R0011_Amendment_6.pdf PDF
RFP_PN87253_LED_Amendment_5.pdf PDF
W912DS18R0011_Amendment_5.pdf PDF
Site_Visit_20_JULY_2018_LED.pdf PDF
Amendment_0004.pdf PDF
Appendix_A_Lighting_Fixture_Schedule_Amendment_4.pdf PDF
W912DS18R0011_Amendment_3.pdf PDF
Appendix_F_Delamp.pdf PDF
RFP_PN87253_LED_Amendment_3.pdf PDF
Appendix_F_Delamp.pdf PDF
RFP_PN87253_LED_Amendment_3.pdf PDF
W912DS18R0011_Amendment_3.pdf PDF
Pages_1-166_from_Appendix_B_Installation_and_Building_Maps_AMENDMENT_2.pdf PDF
Pages_625-781_from_Appendix_B_Installation_and_Building_Maps-5_AMENDMENT_2.pdf PDF
W912DS18R0011_Amendment_2.pdf PDF
Pages_167-331_from_Appendix_B_Installation_and_Building_Maps-2_AMENDMENT_2.pdf PDF
Pages_332-490_from_Appendix_B_Installation_and_Building_Maps-3_AMENDMENT_2.pdf PDF
Appendix_A_Lighting_Fixture_Schedule_AMENDMENT_2.pdf PDF
Amendment_1.pdf PDF
Appendix_A_Lighting_Fixture_Schedule.pdf PDF
Pages_361-540_from_Appendix_B_Installation_and_Building_Maps-3.pdf PDF
Appendix_E_Basis_of_Design.pdf PDF
Pages_541-720_from_Appendix_B_Installation_and_Building_Maps-4.pdf PDF
Appendix_D_Electrical_Drawings.pdf PDF
Pages_181-360_from_Appendix_B_Installation_and_Building_Maps-2.pdf PDF
Pages_721-905_from_Appendix_B_Installation_and_Building_Maps-5.pdf PDF
RFP_PN87253_LED.pdf PDF
Pages_1-180_from_Appendix_B_Installation_and_Building_Maps.pdf PDF
W912DS18R0011.pdf PDF
Appendix_C_Building_Exterior_Lighting_Detail.pdf PDF
Show all 32

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Building 10334 (Same as Building 10111)

Building 10340, 10345, and 10350

This map is a user generated static output from an Internet mapping site and is for reference only.

e3ppmrjb Line e3ppmrjb Line e3ppmrjb Line e3ppmrjb Line e3ppmrjb Line e3ppmrjb Line

A S

N O

T E

D

E-101

SCALE:A

B W

B

T P

0 16’4’ 8’

LIGHTING PLAN - PART A

�" = 1’-0"

L

IG

H T

IN

G P

L A

N P

A R

T A

GENERAL NOTES (THIS SHEET ONLY)

SEE SHEET E-102

SCALE: �" = 1’-0"B

MEZZANINE

LIGHTING PLAN

1. EXIT SIGNS SHOWN ON THIS SHEET SHALL BE FED

FROM EDP1, CIRCUIT 25.

2. EMERGENCY/ NIGHT LIGHTS SHALL BE FED FROM

EDP1, CIRCUIT 12.

3. EXTERIOR EMERGENCY LIGHTS SHALL BE FED

FROM THE UN-SWITCHED LEG OF THE GENERAL

LIGHTING CIRCUIT WHICH SERVES THE INDOOR

ADJACENT AREA.

M J P

W D

C L

A S

S R

O

M

Y O

U T

C H

A N

G E

S

F i l e n a m e

M o d e l

N a m e E

F

P R

O J

E C

T S

D R

A W I N

G S

C o n

D o c s

C A

D

S h e e t s

E l e c t r i c a l

B C

T I F

R E .d g n p d f .p l t

P l o t

D r i v e r j r b

P l o t t e d

B y

:0

:5

M A

2 3 4 5

D

C

B

D E

S C

R

IP

T

IO

N M

A R

K A

P P

R

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

A N

S I D

B C

T

IF

R

E .d g n

SHEET

IDENTIFICATION

V E

T C

O C

O N

T R

A C

T

IN

G S

E R

V

IC

E S

BDA No:

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

R

E W Y

O R

K D

IS

T R

IC

F

R T D

R U

M

N E

W Y

O R

K

11001

New York District

F O

R T D

R U

M

N E

W Y

O R

K

A L L W

E A

T H

E R T

R A

IN

IN

G F

A C

IL

IT

Y R

A N

G E

P N

F

Y

M A

Y

W

D S

D

W

D S

D

1 2 3

B

A

A B

EM

LPP2,4

JAN

STORAGE

102A

VENDING /

RECYCLING

VESTIBULE

AIRLOCK

CONTROL

STORAGE

OFFICE

WOMEN

CLASSROOM

CLASSROOM

TR

CORRIDOR

M A

T C

H P

A R

T A

M A

T C

H P

A R

T B

M A

T C

H P

A R

T A

M A

T C

H P

A R

T B

MOUNT "S" TYPE FIXTURES HIGH

INSIDE CANOPY 9’-0" AFG TYP

LPP2,3 LPP2,3 LPP2,3

LPP2,1 LPP2,1

LPP2,2

LPP2,2

LPP2,2

LPP2,2

LPP2,2

LPP2,1

LPP2,1

LPP2,2

VIA LIGHTING

CONTACTOR -

MEZZANINE ABOVE

REFER TO B/E-101

MEN

LPP2,2

MOUNT FIXTURES

8’-0" AFG TYP UNO

TO LPP1 CKT 35,37 VIA

LIGHTING CONTACTOR

REFER TO DETAIL 1/E-501.

AMMUNITION

SUPPLY POINT

3-WAY DIMMER SWITCH

WITH FULL OFF POSITION

3-WAY SWITCH

PART A PART B

KEY PLAN

RECORD DRAWINGS

THIS DOCUMENT HAS

BEEN UPDATED WITH

AS-BUILT INFORMATION

FURNISHED BY THE

SUBCONTRACTORS.

1/28/2013

T E

D

E-102

SCALE:A

B W

B

T

0 16’4’ 8’

�" = 1’-0"

LIGHTING PLAN - PART B L

IG

H T

IN

G P

L A

N P

A R

T B

GENERAL NOTES (THIS SHEET ONLY)

1. CIRCUITING FOR FIRING RANGE AREA ROOM 115

EMERGENCY LIGHTS SHALL BE PER DETAIL

4/E-501.

2. EXIT LIGHTS FOR FIRING RANGE SHALL BE

FED FROM PANEL EDP1, CIRCUIT 25.

3. EXIT SIGNS SHOWN FOR ROOMS 117-121 SHALL BE FED

FROM EDP1, CIRCUIT 2.

4. EMERGENCY/ NIGHT LIGHTS FOR ROOMS 117-121 SHALL

BE FED FROM EDP1, CIRCUIT 4.

5. EXTERIOR EMERGENCY LIGHTS SHALL BE FED

FROM THE UN-SWITCHED LEG OF THE GENERAL

LIGHTING CIRCUIT WHICH SERVES THE INDOOR

ADJACENT AREA.

SCALE:B

NOT TO SCALE

PROVIDE UNI-STRUT

MOUNTING FOR LIGHT

FIXTURES

SAWTOOTH SECTION

B

E-102

M J P

F

IN

B U

IL

T

F i l e n a m e

M o d e l

N a m e E

F

P R

O J

E C

T S

D R

A W I N

G S

C o n

D o c s

C A

D

S h e e t s

E l e c t r i c a l

B C

T I F

R E .d g n p d f .p l t

P l o t

D r i v e r j r b

P l o t t e d

B y

:0

:5

M A

2 3 4 5

D

C

B

D E

S C

R

IP

T

IO

N M

A R

K A

P P

R

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

S O

L

IC

IT

A T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T E

D B

Y

P L

O T S

C A

L E

P L

O T D

A T

E

C O

N T

R A

C T N

O

A N

S I D

B C

T

IF

R

E .d g n

SHEET

IDENTIFICATION

V E

T C

O C

O N

T R

A C

T

IN

G S

E R

V

IC

E S

BDA No:

U S A

R M

Y C

O R

P S O

F E

N G

IN

E E

W Y

O R

K D

IS

T R

IC

R T D

R U

M

N E

W Y

O R

K

11001

New York District

F O

R T D

R U

M

N E

W Y

O R

K

A L L W

E A

T H

E R T

R A

IN

IN

G F

A C

IL

IT

Y R

A N

G E

P N

F

Y

M A

Y

W

D S

D

W

D S

D

3 4 5

B

A

SHOWER

FIRING RANGE

AREA

ELECTRICAL

MECHANICAL

BOILER ROOM

SHOWER

M A

T C

H P

A R

T A

M A

T C

H P

A R

T B

M A

T C

H P

A R

T A

M A

T C

H P

A R

T B

MOUNT "Q" TYPE

FIXTURES AT CANOPY

1’-6" BELOW CEILING.

TYP.

MOUNT "S" TYPE FIXTURES HIGH

INSIDE CANOPY 9’-0" AFG TYP

MOUNT FIXTURE

2’-0" BEHIND

FIRING LINE. TYP

LPP1,1

LPP1,4

MOUNT FIXTURES

ON FLAT CEILING

SEE SHEET E-101

MOUNT FIXTURES ON VERTICAL PART OF

BAFFLE SAWTOOTH, AS LOW AS POSSIBLE

WITHOUT BEING VISIBLE AT FIRING LINE

TO LPP3,

CIRCUIT 2

VIA LIGHTING

CONTACTOR -

SEE 3/E-501

LPP1,1

LPP1,1

TO LPP3,

CIRCUIT 2

VIA LIGHTING

CONTACTOR -

SEE 3/E-501

TO LPP3,

CIRCUIT 3

VIA LIGHTING

CONTACTOR -

SEE 3/E-501

TO LPP3, CIRCUIT 6 VIA LIGHTING

CONTACTOR AND DIMMER SWITCH -

SEE 3 AND 6 ON E-501

TO LPP3, CIRCUIT 6 VIA LIGHTING

CONTACTOR AND DIMMER SWITCH -

SEE 3 AND 6 ON E-501

BULLET TRAP

FULL HEIGHT

SEPARATION

LPP1,2

EMERGENCY LIGHTING

SHALL BE FED FROM

THE GENERAL LIGHTING

CIRCUIT THAT FEEDS

THE SAME AREA (TYP)

MOUNT EM REMOTE HEADS

HIGH ON WALL ABOVE

BALLISTIC ENVELOPE (TYP)

TYPE "AA" FIXTURES

AS SHOWN. MOUNT

1’-0" BEHIND FIRING

LINE

TO LPP3, CIRCUITS 4 VIA

LIGHTING CONTACTOR -

SEE 3/E-501

COORDINATE LIGHT

FIXTURES THIS

AREA WITH ALL

OTHER TRADES

TO LPP1 CKT 35,37 VIA

LIGHTING CONTACTOR

REFER TO DETAIL 1/E-501.

PART A PART B

KEY PLAN

AS-BUILT INFORMATION

FURNISHED BY THE

REF:

FIRST FLOOR

100' - 0"

REF:

T/ WALL

113' - 6"

B A

STANDING SEAM METAL ROOF,

SSMR-1

CONTINUOUS PRECAST

CONCRETE ACCENT

BAND, PC-1

SPLIT FACE CMU,

SFCMU-1

FRP DOORS W/ ALUM

FRAME, FRP-1

METAL PANEL, MP-1

ATFP COMPLIANT WINDOW,

WF-1

SOLAR COLLECTOR PANEL,

SCP-1

CJ CJ

PV ARRAYS

REF:

FIRST FLOOR

100' - 0"

REF:

T/ WALL

113' - 6"

BA

STANDING SEAM METAL ROOF,

SSMR-1

CONTINUOUS PRECAST

CONCRETE ACCENT

BAND, PC-1

SPLIT FACE CMU,

SFCMU-1

FRP DOORS W/ ALUM

FRAME, FRP-1METAL PANEL, MP-1

L2, L-1

SOLAR COLLECTOR

PANEL BEYOND

CJCJ

LOUVER BEYOND, L-3

LOUVER BEYOND,

L-5

EARDSLEYB ESIGND

SSOCIATESA

Architecture, Engineering & Landscape Architecture, P.C.

SHEET

IDENTIFICATION

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

US Army Corps of Engineers

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

BDA No:

AN

SI

D M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

M

AR

K

SU

BM

IT

TE

D B

Y:C

KD

B Y:

PL

O

T

SC

AL

E:

SI

ZE

FI

LE

N

AM

E:

PL

O

T D

AT

E:

D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

Pl ot te d:

Fi le na m e:

V

ET

C O

C O

N T

R A

C T

IN

G

S E

R V

IC

E

S

54321

A

B

C

D

© COPYRIGHT 2010 THIS DOCUMENT MAY NOT BE REPRODUCED WITHOUT WRITTEN PERMISSION FROM BDA.

2/ 5/

:3

0:

A M

C :\U se rs

\m lm

\D oc um en ts \1

\G _1

-m lm

.rv t

/8

'-0

FO

RT

D

RU

M, N

EW

Y

OR

K

A-203

Au th or C he ck er

D es ig ne r

11001

JU

LY

2, W

2D S-

-D

-0

W

2D S-

-D

-0

7-

New York District

G _1

EX

TE

RI

OR

E

LE

VA

TI

ON

S

US

A

RM

Y

CO

RP

S

OF

E

NG

IN

EE

RS

NE

W Y

OR

K

DI

ST

RI

CT

FO

RT

D

RU

M, N

EW

Y

OR

K

AL

L W

EA

TH

ER

T

RA

IN

IN

G

FA

CI

LIT

Y

RA

NG

E

PN

7, FY

SCALE: 1/8" = 1'-0"B WEST ELEVATION

SCALE: 1/8" = 1'-0"A EAST ELEVATION

EXTERIOR FINISH SCHEDULE

KEY MATERIAL DESIGN BASIS - MANUFACTURER COLOR

MP-1 METAL PANEL CENTRIA MATCH BENJAMIN MOORE #1222 LENAPE TRAIL

PC-1 PRECAST CONCRETE STEPS PLUS FORT DRUM BUFF

SSMR-1 STANDING SEAM METAL ROOFING MBCI SLATE GRAY (MATCH TO "GREY TWEED")

WF-1 WINDOW FRAME EFCO BRONZE

FRP-1 FRP DOORS EFCO DARK BRONZE

SFCMU-1 SPLIT FACE CMU TAYLOR CONCRETE 10TH MOUNTAIN TAN

L-1 LOUVERS RUSKIN LENAPE TRAIL

SCP-1 SOLAR COLLECTOR PANEL ATAS - INSPIRE WALL CLASSIC BRONZE

AF-1 ALUMINUM DOORS AND FRAMES EFCO BRONZE

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

LOUVER SCHEDULE

LOUVER DIMENSION HEIGHT AFF TO

B.O. LOUVER

L1

L2 9' - 4" X 9' - 4" 10' - 8"

7' - 4" X 9' - 4" 4' - 0"

L8 NOT USED -

L3 1' - 4" X 1' - 4" 8' - 0"

L4

L5 1' - 4" X 1' - 4" 8' - 8"

10' - 0"

L6 1' - 4" X 0' - 8" 10' - 8"

L7 3' - 0" X 2' - 0" 10' - 0"

1' - 4" X 1' - 4"

L9 2' - 6" X 2' - 6" HORIZONTAL

FI

N

AL

A S-

BU

IL

TS

1/

/1

TJ

AS-BUILT INFORMATION

FURNISHED BY THE

100' - 0"

REF:

T/ WALL

113' - 6"

1 2

STANDING SEAM

METAL ROOF, SSMR-1

CONTINUOUS PRECAST

CONCRETE ACCENT BAND,

PC-1

SPLIT FACE CMU, SFCMU-1METAL PANEL,

MP-1

ATFP COMPLIANT

WINDOW, WF-1

M

AT

C H

PA

R T

A M

AT

C

H

PA

R

T B

ALUMINUM STOREFRONT

DOORS, AF-1

SOLAR COLLECTOR

PANEL, SCP-1

CJ CJ CJ CJ CJ

PV ARRAYS

LOCK BOX

1 1 1 1

REF:

FIRST FLOOR

100' - 0"

REF:

T/ WALL

113' - 6"

3 4 5

SPLIT FACE CMU, SFCMU-1METAL PANEL, MP-1

STANDING SEAM METAL ROOF, SSMR-1

CONTINUOUS PRECAST CONCRETE

ACCENT BAND, PC-1

CJ CJ CJ CJ CJ CJ CJ CJ

PV ARRAYS

BOLLARDS, TYPL4, L-1L6, L-1

M

AT

C H

PA

R T

A M

AT

C

H

PA

R

T B

EARDSLEYB ESIGND

SSOCIATESA

Architecture, Engineering & Landscape Architecture, P.C.

SHEET

IDENTIFICATION

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

US Army Corps of Engineers

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

BDA No:

AN

SI

D M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

M

AR

K

SU

BM

IT

TE

D B

Y:C

KD

B Y:

PL

O

T

SC

AL

E:

SI

ZE

FI

LE

N

AM

E:

PL

O

T D

AT

E:

D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

Pl ot te d:

Fi le na m e:

V

ET

C O

C O

N T

R A

C T

IN

G

S E

R V

IC

E

S

54321

A

B

C

D

© COPYRIGHT 2010 THIS DOCUMENT MAY NOT BE REPRODUCED WITHOUT WRITTEN PERMISSION FROM BDA.

2/ 5/

:3

0:

A M

C :\U se rs

\m lm

\D oc um en ts \1

\G _1

-m lm

.rv t

/8

'-0

FO

RT

D

RU

M, N

EW

Y

OR

K

A-201

Au th or C he ck er

D es ig ne r

11001

JU

LY

2, W

2D S-

-D

-0

W

2D S-

-D

-0

7-

New York District

G _1

EX

TE

RI

OR

E

LE

VA

TI

ON

S

US

A

RM

Y

CO

RP

S

OF

E

NG

IN

EE

RS

NE

W Y

OR

K

DI

ST

RI

CT

FO

RT

D

RU

M, N

EW

Y

OR

K

AL

L W

EA

TH

ER

T

RA

IN

IN

G

FA

CI

LIT

Y

RA

NG

E

PN

7, FY

SCALE: 1/8" = 1'-0"A SOUTH ELEVATION - PART A

SCALE: 1/8" = 1'-0"B SOUTH ELEVATION - PART B

EXTERIOR FINISH SCHEDULE

KEY MATERIAL DESIGN BASIS - MANUFACTURER COLOR

MP-1 METAL PANEL CENTRIA MATCH BENJAMIN MOORE #1222 LENAPE TRAIL

PC-1 PRECAST CONCRETE STEPS PLUS FORT DRUM BUFF

SSMR-1 STANDING SEAM METAL ROOFING MBCI SLATE GRAY (MATCH TO "GREY TWEED")

WF-1 WINDOW FRAME EFCO BRONZE

FRP-1 FRP DOORS EFCO DARK BRONZE

SFCMU-1 SPLIT FACE CMU TAYLOR CONCRETE 10TH MOUNTAIN TAN

L-1 LOUVERS RUSKIN LENAPE TRAIL

SCP-1 SOLAR COLLECTOR PANEL ATAS - INSPIRE WALL CLASSIC BRONZE

AF-1 ALUMINUM DOORS AND FRAMES EFCO BRONZE

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

LOUVER SCHEDULE

LOUVER DIMENSION HEIGHT AFF TO

B.O. LOUVER

L1

L2 9' - 4" X 9' - 4" 10' - 8"

7' - 4" X 9' - 4" 4' - 0"

L8 NOT USED -

L3 1' - 4" X 1' - 4" 8' - 0"

L4

L5 1' - 4" X 1' - 4" 8' - 8"

10' - 0"

L6 1' - 4" X 0' - 8" 10' - 8"

L7 3' - 0" X 2' - 0" 10' - 0"

1' - 4" X 1' - 4"

L9 2' - 6" X 2' - 6" HORIZONTAL

C

O N

ST

R

U C

TI

O

N U

PD

AT

E 3/

6/

AS-BUILT INFORMATION

FURNISHED BY THE

100' - 0"

REF:

T/ WALL

113' - 6"

M

AT

C H

PA

R T

B M

AT

C

H

PA

R

T A

STANDING SEAM METAL ROOF, SSMR-1

FRP DOOR W/ ALUMINUM

FRAME, FRP-1

CONTINUOUS PRECAST

CONCRETE ACCENT BAND, PC-1

SPLIT FACE CMU,

SFCMU-1

METAL PANEL,

MP-1

CJCJCJCJCJ

PV ARRAYS L7, L-1

REF:

FIRST FLOOR

100' - 0"

REF:

T/ WALL

113' - 6"

STANDING SEAM METAL ROOF, SSMR-1

SPLIT FACE CMU, SFCMU-1CONTINUOUS PRECAST CONCRETE

ACCENT BAND, PC-1

METAL PANEL, MP-1FRP DOOR W/ ALUM

FRAME, FRP-1

L1, L-1

CJCJCJCJCJCJCJCJ

PV ARRAYS

L4, L-1

M

AT

C H

PA

R T

B M

AT

C

H

PA

R

T A

EARDSLEYB ESIGND

SSOCIATESA

Architecture, Engineering & Landscape Architecture, P.C.

SHEET

IDENTIFICATION

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

US Army Corps of Engineers

D

ES

IG

N

ED

B

Y:

D W

N B

Y:

BDA No:

AN

SI

D M

AR

K

D

ES

C R

IP

TI

O N

D

AT

E

AP

PR

M

AR

K

SU

BM

IT

TE

D B

Y:C

KD

B Y:

PL

O

T

SC

AL

E:

SI

ZE

FI

LE

N

AM

E:

PL

O

T D

AT

E:

D

AT

E:

SO

LI

C

IT

AT

IO

N N

O

C O

N

TR

AC

T

N O

FI

LE

N U

M

BE

R

Pl ot te d:

Fi le na m e:

V

ET

C O

C O

N T

R A

C T

IN

G

S E

R V

IC

E

S

54321

A

B

C

D

© COPYRIGHT 2010 THIS DOCUMENT MAY NOT BE REPRODUCED WITHOUT WRITTEN PERMISSION FROM BDA.

2/ 5/

:3

0:

A M

C :\U se rs

\m lm

\D oc um en ts \1

\G _1

-m lm

.rv t

/8

'-0

FO

RT

D

RU

M, N

EW

Y

OR

K

A-202

Au th or C he ck er

D es ig ne r

11001

JU

LY

2, W

2D S-

-D

-0

W

2D S-

-D

-0

7-

New York District

G _1

EX

TE

RI

OR

E

LE

VA

TI

ON

S

US

A

RM

Y

CO

RP

S

OF

E

NG

IN

EE

RS

NE

W Y

OR

K

DI

ST

RI

CT

FO

RT

D

RU

M, N

EW

Y

OR

K

AL

L W

EA

TH

ER

T

RA

IN

IN

G

FA

CI

LIT

Y

RA

NG

E

PN

7, FY

SCALE: 1/8" = 1'-0"A NORTH ELEVATION - PART A

SCALE: 1/8" = 1'-0"B NORTH ELEVATION - PART B

EXTERIOR FINISH SCHEDULE

KEY MATERIAL DESIGN BASIS - MANUFACTURER COLOR

MP-1 METAL PANEL CENTRIA MATCH BENJAMIN MOORE #1222 LENAPE TRAIL

PC-1 PRECAST CONCRETE STEPS PLUS FORT DRUM BUFF

SSMR-1 STANDING SEAM METAL ROOFING MBCI SLATE GRAY (MATCH TO "GREY TWEED")

WF-1 WINDOW FRAME EFCO BRONZE

FRP-1 FRP DOORS EFCO DARK BRONZE

SFCMU-1 SPLIT FACE CMU TAYLOR CONCRETE 10TH MOUNTAIN TAN

L-1 LOUVERS RUSKIN LENAPE TRAIL

SCP-1 SOLAR COLLECTOR PANEL ATAS - INSPIRE WALL CLASSIC BRONZE

AF-1 ALUMINUM DOORS AND FRAMES EFCO BRONZE

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

LOUVER SCHEDULE

LOUVER DIMENSION HEIGHT AFF TO

B.O. LOUVER

L1

L2 9' - 4" X 9' - 4" 10' - 8"

7' - 4" X 9' - 4" 4' - 0"

L8 NOT USED -

L3 1' - 4" X 1' - 4" 8' - 0"

L4

L5 1' - 4" X 1' - 4" 8' - 8"

10' - 0"

L6 1' - 4" X 0' - 8" 10' - 8"

L7 3' - 0" X 2' - 0" 10' - 0"

1' - 4" X 1' - 4"

L9 2' - 6" X 2' - 6" HORIZONTAL

W

D

C

LA

SS

R O

O M

L

AY

O U

T C

H

AN

G

ES

7/

/1

C

O N

ST

R

U C

TI

O

N U

PD

AT

E 3/

6/

FI

N

AL

A S-

BU

IL

TS

1/

/1

TJ

F

AS-BUILT INFORMATION

FURNISHED BY THE

Building 10345

Ft Drum Map Book Block: 10400

11400

10500

10400

10300

10200

11300

10600

10100

11100

10000

RO

C

K

777720

16 7766

10 50

88448822

8811 8833

³Boundary Fence 0 425 850 1,700 2,550 3,400 Feet

Railroad Road

Parking/Driveway Athletic FieldTHIS MAP BOOK IS PRODUCED BY

PUBLIC W ORKS, MASTER PLANNING

FORT DRUM, NY

Brad Dugger- 772-0438 Date Saved: 11/7/2017

Legend

Building 10400

Building 10400 (Same as Building 10200)

Building 10410

Building 10410 (Same as Building 10120)

Building 10412

Building 10412 (Same as Building 10122)

Building 10414

Building 10414

Building 10416

100' - 0"

79 5 3 11112 68 410 2

DOUBLE HUNG WINDOW CONTINUOUS PRECAST

CONCRETE BAND

SPLIT FACE MASONRY

STANDING SEAM ROOF

T/ WALL

112' - 8"

STANDING SEAM METAL

FASCIA

BRICK COLUMN WRAPBRICK SOLDIER COURSEBRICK VENEER OUTLINE OF BUILDING BEYOND

OUTLINE OF ROOF

BEYOND

BRICK VENT BEYOND - COORD

W/ MECHANICAL

BRICK VENT - COORD

W/ MECHANICAL

CJT CJT CJT CJT CJT CJT CJT CJT CJT CJTCJTCJTCJT

ATFP COMPLIANT

DOUBLE HUNG

WINDOWS

FIRST FLOOR

100' - 0"

CBA D

A-A

A-302

T/ WALL

112' - 8"

SKYLIGHT

STANDING SEAM METAL

FASCIA

BRICK COLUMN WRAP

BRICK SOLDIER COURSE OUTLINE OF BUILDING

BEYOND

STANDING SEAM METAL ROOF

OUTLINE OF ROOF BEYOND

CONTINUOUS PRECAST

CONCRETE BAND

SPLIT FACE MASONRY

ATFP COMPLIANT DOUBLE

HUNG WINDOW

BRICK VENEER

L2

STANDING SEAM

METAL FASCIA

CJT CJT CJT CJT CJT CJT

FIRST FLOOR

100' - 0"

7 9531 11 126 84 102

T/ WALL

112' - 8"

STANDING SEAM METAL FASCIABRICK COLUMN WRAP CONTINUOUS PRECAST

CONCRETE BAND

SPLIT FACE MASONRY BRICK SOLDIER COURSE DOUBLE HUNG WINDOW BRICK VENEER

STANDING SEAM METAL ROOFSKYLIGHTSTANDING SEAM

METAL PANEL

/8

L3

ALUMINUM GRILLE SYSTEMBOILER INTAKES

CJT CJT CJT CJT CJT CJT

CJT

CJT CJT CJT CJT CJT

ATFP COMPLIANT DOUBLE

HUNG WINDOWS

L1

C B AD

A-A

A-302

SKYLIGHT

STANDING SEAM METAL

FASCIA

BRICK COLUMN WRAP

OUTLINE OF BUILDING

BEYOND

BRICK VENEER

CONTINUOUS PRECAST

CONCRETE BAND

SPLIT FACE MASONRY

OUTLINE OF ROOF

BEYOND

BRICK SOLDIER COURSE

STANDING SEAM

METAL ROOF

STANDING SEAM

METAL FASCIA

CJT CJT CJT CJT CJT CJT CJT

ATFP COMPLIANT DOUBLE

HUNG WINDOW

BATTALION HEADQUARTERS

LOUVER SCHEDULE

L1 8'-8" W x 4'-0" H

L2 8'-0" W x 6'-0" H

L3 1'-4" W x 1'-4" H

L4 BRICK VENT

LOUVER DIMENSION BASE HEIGHT AFF

7'-8"

14'-8"

10'-0"

10'-0"

NOTES:

1. LOUVER FRAMES ARE 1 1/2" WIDE.

2. PROVIDE MULLIONS AT 5'-0" OC FOR LOUVERS

OVER 9'-0" WIDE.

3. LOUVER HEIGHT IN SCHEDULE IS FROM AFF;

GRADE IS 6" BELOW AFF.

SHEET

IDENTIFICATION

S ym bo l

D es cr ip tio n

D at e A pp r.

D es ig n fil e:

US Army Corps of Engineers

S et

ID

S iz e:

P lo t d at e:

D es ig ne d by

D ra w n by

C he ck ed b y:

R es po ns ib le

P .E

Li ce ns e nu m be r:

Li ce ns e st at e:

BDA No:

A R

C H

D

54321

A

B

C

D

A

B

C

D

F O

R T

D R

U M

N

E W

Y O

R K

4/

/2

9:

:5

A

M

A-203

M

LF

C he ck er

M

LF

Is su e D at e

B A

T T

A L

IO

N H

E A

D Q

U A

R T

E R

S E

X T

E R

IO

R

E L E

V A

T

IO

N S

B R

IG

A

D E

C O

M B

A T

T E

M

C

O N

D

C O

M P

L E

X P

H A

S E

A R

C H

IT

E

C T

U R

A L

F O

R T

D R

U M

07015

SCALE: 1/8" = 1'-0"A

BATTALION HEADQUARTERS

NORTH ELEVATION

SCALE: 1/8" = 1'-0"C

BATTALION HEADQUARTERS

WEST ELEVATION

SCALE: 1/8" = 1'-0"B

BATTALION HEADQUARTERS

SOUTH ELEVATION

SCALE: 1/8" = 1'-0"D

BATTALION HEADQUARTERS

EAST ELEVATION

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

1. EXTERIOR BUILDING SIGNAGE LOCATION TO BE COORDINATED WITH CONTRACTING OFFICER.

R

E M

O V

A L

O F

H

IP

F R

O M

S K

Y

LI

G H

T

RECORD DRAWINGS

THIS DOCUMENT HAS BEEN UPDATED

WITH AS-BUILT IN

FORMATION FURNISHED

BY THE SUBCONTRACTORS.

4/20/2009 ic e n s e S ta te

:e p l b r i g a .d g n

D a te

A p p r.

D e s c r ip ti o n

S y m b o l

D r a w n b y

D e s ig n f il e

P lo t d a te

C h e c k e d b y

D e s ig n e d b y

R e s p o n s ib le P

.E

L ic e n s e N u m b e r

S e t

I D

S iz e

A R

C H

D

SHEET

IDENTIFICATION

BDA No:

A

B

D

C

1 2 3 4 5

D

C

B

A

F il e n a m e

M o d e l

N a m e

E L

F

P R

O J E

C T

S \0

\D R

A W

IN

G

S \e p l-

-b ri g -a

.d g n p d f .p lt P lo t

D r iv e r

JC

G

/2

/2

P lo tt e d

B y

:1

:3

A

M

U N

S T

A M

P E

D

07015

B R

IG

A

D E

C O

M B

A T

T E

A M

S E

C O

N D

C O

M P

L E

X P

H A

S E

I H e a ti n g a n d C o o li n g

In c

F O

R T

D R

U M

W A

T E

R T

O W

N N

E W

Y O

R K

RECORD D

RAW

IN

GS

THIS

D

OCUM

ENT H

AS B

EEN U

PDATED

W

IT

H A S-B

UIL

T IN

FORM

ATIO

N F

URNIS

HED

BY T

HE S

UBCONTRACTORS.

4/2 0/2

E1 E2 E3 E3.4 E4A1 A5 A7A3 A10A8A6A4A2 A9

VESTIBULE

VESTIBULE

IOO

IS

VESTIBULE

1 a a1 a1 a1 a1 a1 a1 a1 a1 a6 a a a1 a a6 a a a a3 a2 a2 a2 a2 a2 a2 a a a a a3 b5 a5 a a5 a

6 a 6 a a

3 a a a a a 2

3 a 2 a 2 a a 2 a 2 a 6 a

6 a

3 a

CENTRAL

FILES

AVO

IS

TC

CORRIDOR

S3

OFFICE

HGT IO ASIT

VESTIBULE

MPT

CORRIDOR

a5

5 a

5 b b5 a5

5 a

5 b b5 5 a

BREAK

ROOM

WOMEN’S

TOILET

TOILET

MEN’S

MECHANICAL

ROOM

IS

OFFICE

MOO

a3 a a a a

5 a a6

6 a

2 a 6 a a6

OS

2 a 2 a 2 a 2 a a1 a a1 a1 a3

1 a

3 a

O S

O S

BREAK

ROOM

ELECTRICAL

ROOM

O S

O S a,b a,b a b

OO

COMM ROOM

SIPRNET

ROOM

TELECOM

OS1

O S

O S

3 X

O S

4 4 4 4 4 4 4 4 a

S2

WORK SPACE

SCI

COMM

ROOM

TOILET

MECHANICAL

ROOM

JAN

PASSAGEWAY

BRIEFING

ROOM

O S

OFFICE

O S

PASSAGEWAY

VESTIBULE

2 2

LO

a1 a

O S

E M

EM

EM

EM

NL NL

NL

EM

NLNL

NL

X

VESTIBULE

NL

MDP

EM

CORRIDOR

EM

EM

NL

NL

NL

EM

LP1

a66 a a66 a a a a22 a

3 aa3 a33 a a3 3 a 5 aa5 5 a a5

3 a a3 3 a a3

4 a a4 a4

5 a a5

PANEL

LP-2

NL

XEMXEM

XEM

EM1

WP

EM1

WPWP

EM1

EM1

WP

E M

EM

EM

EM

EM1

WP

X

X

67676767

67 67 67

LV

44 4

NL

JANITOR

43 43

AA

BB

AA

AA

AA

AA

AA AA

X

X

X

X

SCIF AREA

X

X

LCP-2

LCP-1

EM-1

SCIF

ATS

CP-1

EMEMEM

OS

EM

17 17

17 17

17 17

NL

17 17

161616

161616

PP-S1

PP-1

NL

12 EM-1

EM-112

12 EM-1 EM-112

EM-112

EM-112

12 EM-1

EM-1

EM-1 EM-1

12 12

EM-1 EM-1

12 12

EM-1EM-1 12

EM-1 EM-1

EM-1

EM-1 EM-1

12 12

EM-1

EM-1

EM-1

RECESS IN GRID CEILING.

TYPICAL FIXTURES

THIS CORRIDOR.

NL

XEM

X E

M

LV

XEM

X E

M

O S

E M

MASS NOTIFICATION

CONTROL PANEL

LCP3

FIRE ALARM

CONTROL PANEL

SCALE:A 1/8 " = 1’-0"

BRIGADE HEADQUARTERS

FIRST FLOOR LIGHTING PLAN - PART A

E L

E C

T R

IC

A

L

B R

IG

A

D E

H E

A D

Q U

A R

T E

R S

EL101

F

IR

S T

F L

O O

R L

IG

H

T

IN

G P

L A

N

P A

R T

A

KEYED NOTES (THIS DRAWING ONLY)

1.

GENERAL NOTES

M A

T C

H L

IN

E

M A

T C

H L

IN

E

1 2

BRANCH CIRCUIT NOTES (THIS DRAWING ONLY)

CIRCUIT ALL EXIT AND NIGHT LIGHT (NL) FIXTURES IN

SCIF AREA TO PANEL LP-S1, #1.

1/8" = 1’-0"

0’ 4’ 8’ 12’ 16’

UNLESS NOTED OTHERWISE, CIRCUIT ALL LIGHTING TO PANEL LP-1.

CIRCUIT THROUGH LIGHTING CONTROL PANEL LCP-1 IN ELECTRIC

ROOM A132. CIRCUIT ALL EXIT AND NL LIGHTING TO PANEL EM-1

CKT #14.

UNLESS NOTED OTHERWISE, CIRCUIT ALL LIGHTING

TO PANEL LP-2.

UNLESS NOTED OTHERWISE, CIRCUIT ALL SCIF LIGHTING

TO PANEL PP-S1. CIRCUIT ALL EXIT AND NL LIGHTING

IN SCIF TO PP-S1 #15.

T S

M

JP

C O

N S

T R

U C

T

IO

N U

P D

A T

E

CONNECT LIGHTING CIRCUIT(S) TO LIGHTING CONTROL PANEL.

PANEL CP-S1.

LOW VOLTAGE OVERRIDE SWITCHES. PROVIDE 3 OVERRIDE SWITCHES,

ONE EACH FOR CKTS 3,4,AND 5.

LOW VOLTAGE OVERRIDE SWITCHES. PROVIDE ONE LOW VOLTAGE,

MULTI-BUTTON SWITCH. PROVIDE SWITCH WITH ONE MASTER ON/OFF

BUTTON AND 5 BUTTONS FOR OVERRIDE OF INDIVIDUAL CIRCUITS.

(ONE BUTTON FOR EACH CIRCUIT #6,67,2,5,4).

CIRCUIT EXTERIOR POLE AND WALKWAY LIGHTING TO PANEL LP-1 #68,70.

CIRCUIT THROUGH LIGHTING CONTROL PANEL LCP-3 IN ELECTRIC ROOM

A132.

CIRCUIT EXTERIOR BUILDING MOUNTED FIXTURES TO PANEL LP-1 #71,73.

CIRCUIT THROUGH LIGHTING CONTROL PANEL LCP-3 IN ELEC ROOM A132.

RUN WIRING INSIDE BUILDING EXCEPT AT SCIF AREA. PROVIDE #10 CONDUCTORS.

LOW VOLTAGE OVERRIDE SWITCH. PROVIDE LOW VOLTAGE, MULTI-BUTTON SWITCH.

PROVIDE SWITCH WITH ONE MASTER ON/OFF BUTTON AND 2 BUTTONS FOR OVERRIDE

OF INDIVIDUAL CIRCUITS (ONE BUTTON FOR EACH CIRCUIT # 1 AND 3).

C O

N S

T R

U C

T

IO

N U

P D

A T

E

C O

N S

T R

U C

T

IO

N U

P D

A T

E

R

E C

O R

D D

R A

W

IN

G S ic e n s e S ta te

:e p l b r i g b

.d g n

D a te

A p p r.

D e s c r ip ti o n

S y m b o l

D r a w n b y

D e s ig n f il e

P lo t d a te

C h e c k e d b y

D e s ig n e d b y

R e s p o n s ib le P

.E

L ic e n s e N u m b e r

S e t

I D

S iz e

A R

C H

D

SHEET

IDENTIFICATION

BDA No:

A

B

D

C

1 2 3 4 5

D

C

B

A

F il e n a m e

M o d e l

N a m e

E L

F

P R

O J E

C T

S \0

\D R

A W

IN

G

S \e p l-

-b ri g -b

.d g n p d f .p lt P lo t

D r iv e r

JC

G

/2

/2

P lo tt e d

B y

:1

:1

A

M

U N

S T

A M

P E

D

07015

B R

IG

A

D E

C O

M B

A T

T E

A M

S E

C O

N D

C O

M P

L E

X P

H A

S E

I H e a ti n g a n d C o o li n g

In c

F O

R T

D R

U M

W A

T E

R T

O W

N N

E W

Y O

R K

RECORD D

RAW

IN

GS

THIS

D

OCUM

ENT H

AS B

EEN U

PDATED

W

IT

H A S-B

UIL

T IN

FORM

ATIO

N F

URNIS

HED

BY T

HE S

UBCONTRACTORS.

4/2 0/2

IOO

VESTIBULE

VESTIBULE

OFFICE

a 1 a a a a a

BJA

DC

ROOM

CONFERENCE

COMMANDER

CAO

SST C2SI

EO

CORRIDOR

a,b ba

OS1

a,b a,b111

FS S1

2 2

2 2

OJA CHAPLAIN CH A

4 4 4

4 4 44

5 5 55

5 5 5 55 5

BXO

EAO

LO

X

NL

NL

NL

PANEL

LP-2

NL

EM

NL

NL

EM NL EM

WP

EM1

EM

EM

WP

EM1

43 43 43 43

43434343

JANITOR

43 43 a,b a,b a,b44 44 44

44 44 44

TOILET

44 a,b 44 a,b 44 a,b a b a b

BB

X

X X

EM

LCP-2

EM

EM

A

XEM

LV

44 44

44 44

44 44

OS2

D

X E

M

E3.4 E4 E5 E5.6 E7 E8 E9E6 E10

EA

EB

EC

AD

AC

AE

AB

AA -

SCALE:A 1/8 " = 1’-0"

BRIGADE HEADQUARTERS

E L

E C

T R

IC

A

L

B R

IG

A

D E

H E

A D

Q U

A R

T E

R S

F

IR

S T

F L

O O

R L

IG

H

T

IN

G P

L A

N

P A

R T

B

EL102

FIRST FLOOR LIGHTING PLAN - PART B

KEYED NOTES (THIS DRAWING ONLY)

BRANCH CIRCUIT NOTES (THIS DRAWING ONLY)

1 2

1 2

1/8" = 1’-0"

0’ 4’ 8’ 12’ 16’

UNLESS NOTED OTHERWISE, CIRCUIT ALL LIGHTING

TO PANEL LP-1.

UNLESS NOTED OTHERWISE, CIRCUIT ALL LIGHTING

TO PANEL LP-2. CIRCUIT THROUGH LIGHTING CONTROL

PANEL LCP-2 AT JAN A114. CIRCUIT ALL EXIT AND

NIGHT LIGHTING TO EM-1 CKT # 15.

T S

M

JP

C

O N

S T

R U

C T

IO

N

U P

D A

T E

CONNECT LIGHTING CIRCUIT(S) TO LIGHTING

CONTROL PANEL.

CIRCUIT EXTERIOR BUILDING MOUNTED LIGHTS AND

CANOPY LIGHTS TO PANEL LP-2 #46,48. CIRCUIT

THROUGH LIGHTING CONTACTOR IN ELECTRIC ROOM.

PROVIDE #10 CONDUCTORS. RUN WIRING INSIDE

BUILDING.TYPICAL.

LOW VOLTAGE OVERRIDE SWITCH. PROVIDE LOW

VOLTAGE MULTI BUTTON SWITCH. PROVIDE SWITCH

WITH ONE MASTER ON/OFF BUTTON AND 5 BUTTONS

FOR OVERRIDE OF INDIVIDUAL CIRCUITS. (ONE

BUTTON EACH FOR CKT #1,2,4,43,5).

Building 10416

Building 10420

Building 10420

Building 10422

Building 10422

Building 10432 and 10434

Building 10432 (same layout as Building 10434)

Building 10432 and 10434

Building 10434

Building 10450

Building 10450

Building 10480 and 10481

Building 10480

Building 10480 and 10481

ELECTRICAL PLAN:

1. Furnished and installed a 3 phase 480v 100 amp secondary service from existing mechanical room in building P-10270. Power is fed from existing gear, 100 amp spare breaker.

2. Furnished and installed a 75 KVA step down transformer in new mechanical room to convert 480v, 100 amps to 208v 200 amps.

3. Furnished and installed 1(ea) 4’ x 8’ x ¾” plywood backboard painted gray for new entrance panel in mechanical room.

4. Furnished and installed 200 amp, 120/208volt, 3 phase, 42-circuit entrance panel in mechanical room.

a. Entrance panel received #4 bare copper ground wire to be clamped to the 5/8”x10’ ground rods.

5. Furnished and installed #4/0 bare copper ground wire and 5/8” ground rods for grounding of pre engineered building columns as per code.

6. Furnished and installed electrical wiring to all electrical circuits and power devices throughout interior and exterior of building to in such a manner to meet NEC code.

7. Furnished and installed EMT conduit, boxes, and fittings to include #12 THHN stranded copper wire for wiring outlets, switches, lights, exit and emergency lights in building areas.

8. Furnished and installed # 12/2 Armored cable, EMT and associated boxes and connectors for wiring office and mechanical room lights, switches and receptacles.

9. Furnished and installed new 2’x4’-40w, T-8 drop-in fluorescent ceiling lights in office.

10. Furnished and installed T-5 high output 3 bulb fixtures in training area and mechanical room.

11. Furnished and installed receptacles, switches and covers as per drawing.

12. Furnished and installed 1(ea) LED Exit emergency combo light over each exit door.

13. Furnished and installed 1(ea) exterior light fixture in each exterior canopy.

a. Exterior lighting fixtures shall be 35 watt Metal halide (pulse start). Exterior lighting shall be installed in accordance with ESA lighting minimization guidelines.

CONSTRUCTION NOES:

1. Furnished a 60’ x 100’ pre-engineered building.

a. Pre-engineered building has a 12’ eave with a 3/12 pitch. Building designed with 70lb snow load and 100 mph wind load.

2. Furnished and installed 3” insulated sandwich panels for building sidewalls.

3. Furnished and installed pre-engineered canopies over each training room entrance.

4. Furnished and installed 21(ea) windows. See drawings for locations.

a. Windows are 2’ x 5’, slider type windows. Windows are installed 8’ above the finished floor so as not to interfere with the placement of mats used in training.

b. Windows are light grey in color.

Building 10481

Block: 10500

10300

10200 10100

11400

10500

10400

10600

10000

R O

C K

2277 2299

0055 06

³Boundary Fence 0 370 740 1,480 2,220 2,960 Feet

Railroad Road

Parking/Driveway Athletic FieldTHIS MAP BOOK IS PRODUCED BY

PUBLIC W ORKS, MASTER PLANNING

FORT DRUM, NY

Brad Dugger- 772-0438 Date Saved: 11/7/2017

Building 10500

Building 10500 (Same as Building 10200)

Building 10502

Building 10502

Building 10510

Building 10510

Building 10512

Building 10512

Building 10514

Building 10514

Building 10520

Building 10520

Building 10522

Building 10522

Building 10524

Building 10524

Building 10550

Building 10550 (Same as Building 10150)

Block: 10600

11400

10500

11500

10400

10700-1

10600

10100

10000

99000

7777 7799

14 6611

88558833

40 5032

956688

906666

³Boundary Fence 0 395 790 1,580 2,370 3,160 Feet

Railroad Road

Parking/Driveway Athletic FieldTHIS MAP BOOK IS PRODUCED BY

PUBLIC W ORKS, MASTER PLANNING

FORT DRUM, NY

Brad Dugger- 772-0438 Date Saved: 11/7/2017

Building 10602

Building 10602 (Same as Building 20332)

Building 10604

Building 10604

Building 10610

Building 10610

Building 10612

Building 10612

Building 10614

Building 10614

Building 10620

Building 10620

Building 10622

Building 10622

Building 10630

Building 10630

Building 10632

Building 10632

Building 10640

Building 10640

Building 10642

Building 10642

Building 10644

Building 10644

Building 10648

Building 10648

Building 10650

Building 10650 (Same as Building 10150)

Building 10663

100' - 0"

REF:

T/O MASONRY

129' - 4"

REF:

T/O WALL

112' - 8"

ATFP COMPLIANT WINDOW W/

SOLDIER COURSE ABOVE

SPLIT FACE CMU

DESIGN BASIS:TAYLOR CONCRETE

COLOR:10TH MOUNTAIN TAN

PRE-CAST CONCRETE ACCENT BAND

DESIGN BASIS: STEPS PLUS

COLOR: 704B

FRP DOORBRICK VENEER

DESIGN BASIS: GLEN-GREY

COLOR: OLD BRIDGE

PRE-CAST CONCRETE ACCENT BAND

DESIGN BASIS: STEPS PLUS

COLOR: 704B

STANDING SEAM METAL

ROOFING SYSTEM

1 2 4 5 7 13 1410

MECHANICAL STACK AND

PLUMBING VENT

6 8 123 9 11

CJT CJT CJT CJT CJT CJT CJT CJT

CJT

L1

L2

METAL FASCIA

REF:

FIRST FLOOR

100' - 0"

REF:

T/O MASONRY

129' - 4"

REF:

T/O WALL

112' - 8"

ATFP COMPLIANT WINDOW

W/ SOLDIER COURSE ABOVE

SPLIT FACE CMU

DESIGN BASIS: TAYLOR CONCRETE

COLOR: 10TH MOUNTAIN TAN

PRE-CAST CONCRETE ACCENT BAND

DESIGN BASIS: STEPS PLUS

COLOR: 704B

OVERHEAD DOORFRP DOORS

STANDING SEAM METAL ROOFING SYSTEMEPDM ROOFING SYSTEM AT

COVERED HARDSTAND

BRICK

VENEER

METAL WALL PANEL

124571314 10 6812 39

REF:

T/O WALL COVERED

HARDSTAND

114' - 0"

CJTCJTCJTCJT

2 2

LOUVER SCHEDULE

L1 96" W x 48" H 17' - 4"

L2 24" W x 16" H 10' - 0"

LOUVER DIMENSION HEIGHT AFF TO

B.O. LOUVER

RECORD DRAWINGS

THIS DOCUMENT HAS BEEN UPDATED

WITH AS-BUILT IN

FORMATION FURNISHED

BY THE SUBCONTRACTORS.

EARDSLEYB ESIGND

SSOCIATESA

Architecture, Engineering & Landscape Architecture, P.C.

PU

R

C E

L L

C O

N

ST

R U

C T

IO

N

C O

R

PO

R A

T

IO

N G

E N

E R

A L

C O

N T

R A

C T

O

W

T E

R T

O W

N , N

.Y

SHEET

IDENTIFICATION

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

US Army Corps of Engineers

D E

S

IG

N E

D B

Y

D W

N B

Y

BDA No:

A N

S I D

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

M A

R K

S U

B M

IT

T

E D

B Y

:C K

D B

Y

P

LO

T S

C A

LE

S

IZ

E

F

IL

E N

A M

E

P

LO

T D

A T

E

D A

T E

S O

LI

C

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

P lo tte d:

F ile na m e:

A

B

C

D

54321

03/29/2010

3/

/2

3:

:0

P

M F

:\P R

O

JE

C T

S \0

\D R

A W

IN

G

S \g

_0

_C

O F

.r vt

/8

'-0

F O R T D R U M , N

E W Y O R K

A-201

B

LT

M A

R

M

LM

/3

0/

08005

A U

G U

S T

, 2

W

2D S

-0 7-

R -0

W

2D S

-0 8-

C -0

New York District g_

5_

C O

F .r vt

C O F E X T E R

IO

R E

LE

V A T

IO

N S

U S A R M Y C O R P S O F E N G

IN

E E R S

N E W Y O R K D

IS

T R

IC

T

F O R T D R U M , N

E W Y O R K

2N D B R

IG

A D E C O M B A T T E A M B C T P H A S E

II

W 2D

S -0 8- C -0

SCALE: 1/8" = 1'-0"A COF WEST ELEVATION

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

SCALE: 1/8" = 1'-0"B COF EAST ELEVATION

F A

C

IL

IT

Y

U P

D A

T E

6/

/2

M

A R

F

IN

A L

F A

C

IL

IT

Y

8/

/2

M

A

2 1

100' - 0"

REF:

T/O MASONRY

129' - 4"

REF:

T/O WALL

112' - 8"

EPDM ROOFING SYSTEM

METAL WALL PANEL

STANDING SEAM METAL

ROOFING SYSTEM

SPLIT FACE CMU

DESIGN BASIS: TAYLOR CONCRETE

COLOR: 10TH MOUNTAIN TAN

PRE-CAST CONCRETE ACCENT BAND

DESIGN BASIS: STEPS PLUS

COLOR: 704B

ATFP COMPLIANT WINDOW

W/ SOLDIER COURSE ABOVE

BRICK VENEER

DESIGN BASIS:GLEN-GERY

COLOR:OLD BRIDGE

A B C D E F G J

MECHANICAL STACK AND

PLUMBING VENT

H

REF:

T/O WALL COVERED

HARDSTAND

114' - 0"

CJT CJT CJT CJT CJT CJTCJT

REF:

FIRST FLOOR

100' - 0"

REF:

T/O MASONRY

129' - 4"

REF:

T/O WALL

112' - 8"

BRICK VENEER

ATFP COMPLIANT WINDOW

W/ SOLDIER COURSE ABOVE

FRP DOORSPLIT FACE CMU

DESIGN BASIS: TAYLOR CONCRETE

COLOR: 10TH MOUNTAN TAN

PRE-CAST CONCRETE ACCENT BAND

DESIGN BASIS: STEPS PLUS

COLOR: 704B

STANDING SEAM

METAL ROOFING SYSTEM

EPDM ROOFING SYSTEM

METAL WALL PANEL

ABCDEFGJ

MECHANICAL STACK AND

PLUMBING VENT

H

REF:

T/O WALL COVERED

HARDSTAND

114' - 0"

CJT CJT CJT CJT CJT CJT CJT CJT

BRICK VENEER

DESIGN BASIS:GLEN-GERY

COLOR:OLD BRIDGE

RECORD DRAWINGS

THIS DOCUMENT HAS BEEN UPDATED

WITH AS-BUILT IN

FORMATION FURNISHED

BY THE SUBCONTRACTORS.

EARDSLEYB ESIGND

SSOCIATESA

Architecture, Engineering & Landscape Architecture, P.C.

PU

R

C E

L L

C O

N

ST

R U

C T

IO

N

C O

R

PO

R A

T

IO

N G

E N

E R

A L

C O

N T

R A

C T

O

W

T E

R T

O W

N , N

.Y

SHEET

IDENTIFICATION

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

US Army Corps of Engineers

D E

S

IG

N E

D B

Y

D W

N B

Y

BDA No:

A N

S I D

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

M A

R K

S U

B M

IT

T

E D

B Y

:C K

D B

Y

P

LO

T S

C A

LE

S

IZ

E

F

IL

E N

A M

E

P

LO

T D

A T

E

D A

T E

S O

LI

C

IT

A

T

IO

N N

O

C O

N T

R A

C T

N O

F

IL

E N

U M

B E

R

P lo tte d:

F ile na m e:

A

B

C

D

54321

03/29/2010

3/

/2

3:

:0

P

M F

:\P R

O

JE

C T

S \0

\D R

A W

IN

G

S \g

_0

_C

O F

.r vt

/8

'-0

F O R T D R U M , N

E W Y O R K

A-202

B

LT

M A

R

M

LM

/3

0/

08005

A U

G U

S T

, 2

W

2D S

-0 7-

R -0

W

2D S

-0 8-

C -0

New York District g_

5_

C O

F .r vt

C O F E X T E R

IO

R E

LE

V A T

IO

N S

U S A R M Y C O R P S O F E N G

IN

E E R S

N E W Y O R K D

IS

T R

IC

T

F O R T D R U M , N

E W Y O R K

2N D B R

IG

A D E C O M B A T T E A M B C T P H A S E

II

W 2D

S -0 8- C -0

SCALE: 1/8" = 1'-0"A COF SOUTH ELEVATION

SCALE: 1/8" = 1'-0"B COF NORTH ELEVATION

0' 8'4' 16' 24'

SCALE : 1/8" = 1'-0"

TA-50 GEAR

STORAGE

TA-50 GEAR

STORAGE

STORAGE

STORAGE

STORAGE

STORAGE

SECURE NON-SENS

ARMS VAULT UNIT STORAGE ARMS VAULT

COMM

NBC

UNIT STORAGE

SECURE NON-SENS

COMM

STORAGE

NBC

STORAGE

ROOM

1SG

STORAGE

CO. CDR.

TRAINING

XO

PLATOON

OFFICE

PLATOON

OFFICE

PLATOON

OFFICE

PLATOON

OFFICE

STORAGE

CONFERENCE

VESTIBULE

SIPRNET

COMM

ELEC

CORRIDOR

MECHANICAL

CORRIDOR

CORRIDOR

CORRIDOR

CORRIDOR

LOBBY

WOMEN

ROOM

MEN

JAN/RECYC

STORAGE

VENDING/

RECYCLING

VESTIBULE

STORAGE

CONFERENCE

PLATOON

OFFICE

OFFICE

PLATOON PLATOON

OFFICE

OFFICE

PLATOON

TRAINING

1SG

STORAGE

CO CDR

XO

STORAGE

FUTURE SIPRNET

FUTURE

A S

N O

T E

D

E-101

SCALE:A

TRUE REF

1/8 " = 1’-0"

0’ 4’ 8’ 12’ 16’

1/8" = 1’-0"SCALE:

COF FIRST FLOOR LIGHTING PLAN - PART A

C O

F F

IR

S

T F

L O

O R

L

IG

H T

IN

G

A

N

P A

R T

A

1.

2.

GENERAL NOTES

UNLESS NOTED OTHERWISE, ALL LIGHTING

IS FED FROM PANEL HV-1

25NL

NL NLNL NL NL

UNLESS NOTED OTHERWISE, CIRCUIT ALL

EXIT LIGHT FIXTURES TO PANEL HV-1,

CKT#25.

3. CIRCUIT TYPE ’AA’, ’BB’ AND ’CC’ FIXTURES

TO PANEL HV-1, CKT#31.

LIGHTING NOTES

(THIS DRAWING ONLY)

PROVIDE LIGHTING CONTACTOR FOR EXTERIOR

LIGHTING. REFER TO DETAIL 7/E-501.

C

O N

S T

R U

C T

IO

N

U P

D A

T E

M

A R

C O

N S

T R

U C

T

IO

N U

P D

A T

E /2

/2

F il e n a m e

M o d e l

N a m e

E -1 f p r o je c ts

\0

\d r a w in g s \c o n d o c s \s h e e ts

\e le c tr ic a l\

B C

T

C O

F E

.d g n p d f .p lt P lo t

D r iv e r b w b

/2

/2

P lo tt e d

B y

:4

:4

P

M

A

2 3 4 5

D

C

B

D E

S C

R

IP

T

IO

N M

A R

K A

P P

R

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

P L

O T

D A

T E

C O

N T

R A

C T

N O

A N

S I

D

BDA No:

B C

T

C O

F -E

-1

.d g n

/2

/2

SHEET

IDENTIFICATION

PART A

PART B PART B

KEY PLAN

W D

S -0

-C

-0

08005

N

D B

R

IG

A D

E C

O M

B A

T T

E A

M

B C

T

P H

A S

E I

I

F O

R T

D R

U M

N

E W

Y O

R K

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

N E

W Y

O R

K D

IS

T

R

IC

T

F O

R T

D R

U M

N

E W

Y O

R K

New York District

W

D S

C

W

D S

R

RECORD D

RAW

IN

GS

THIS

D

OCUM

ENT H

AS B

EEN U

PDATED

W

IT

H A S-B

UIL

T IN

FORM

ATIO

N F

URNIS

HED

BY T

HE S

UBCONTRACTORS.

03/2 9/2 c

EM2

EM2

EM2

EM2

EM2

EM

NL

EM

NL

26 26

26 26

26 26

NL

262626

26 26 26 26

32 32

26262626

26 32

32 32 32 32

32 32

25NLNL

D

262626

D

NL

25 28282828

252525

27272727272727

27 2727272727

27 27 2727

28 28 28

2828 28 28

292929

29 29

292929

2929 29

29 2929

29 2929

2929 29

25NL29

29 29

30 3030 30

30 30

STORAGE

COVERED

HARDSTAND

COVERED

HARDSTAND

COMMCOMM

STORAGE

MEZZANINE MEZZANINE

A S

N O

T E

D

SCALE:B

TRUE REF

1/8 " = 1’-0"

A

TRUE REF

1/8 " = 1’-0"SCALE:

0’ 4’ 8’ 12’ 16’

1/8" = 1’-0"SCALE:

E-102

COF FIRST FLOOR LIGHTING PLAN - PART B

C O

F F

IR

S

T F

L O

O R

L

IG

H T

IN

G

P L

A N

P

A R

T B

A N

D M

E Z

Z A

N

IN

E L

IG

H

T

IN

G F

L O

O R

P L

A N

D C

M

C M

P

COF MEZZANINE LIGHTING FLOOR PLAN - PART A

30 30 30

303030

30 30 30

25NL

30 30 30

303030

30 30 30

303030

30 30

30 30

30 30

30 30

25NL

1.

2.

GENERAL NOTES

UNLESS NOTED OTHERWISE, ALL LIGHTING

IS FED FROM PANEL HV-1

UNLESS NOTED OTHERWISE, CIRCUIT ALL

EXIT LIGHT FIXTURES TO PANEL HV-1,

CKT#25.

3. CIRCUIT TYPE ’AA’, ’BB’ AND ’CC’ FIXTURES

TO PANEL HV-1, CKT#31.

C O

N S

T R

U C

T

IO

N U

P D

A T

E /2

/2

F il e n a m e

M o d e l

N a m e

E -1 f p r o je c ts

\0 \d r a w in g s \c o n d o c s \s h e e ts

\e le c tr ic a l\

B C

T C

O F

E

.d g n p d f .p lt P lo t

D r iv e r b w b

/2

/2

P lo tt e d

B y

:4

:5

P

M

A

2 3 4 5

D

C

B

D E

S C

R

IP

T

IO

N M

A R

K A

P P

R

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E A

P P

R

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D A

T E

F

IL

E N

U M

B E

R

S

IZ

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E

P L

O T

D A

T E

C O

N T

R A

C T

N O

A N

S I

D

BDA No:

B C

T

C O

F E

.d g n

/2

/2

SHEET

IDENTIFICATION

PART A

PART B PART B

KEY PLAN

W D

S -0

-C

-0

08005

N

D B

R

IG

A D

E C

O M

B A

T T

E A

M

B C

T

P H

A S

E I

I

F O

R T

D R

U M

N

E W

Y O

R K

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

N E

W Y

O R

K D

IS

T

R

IC

T

F O

R T

D R

U M

N

E W

Y O

R K

New York District

W

D S

C

W

D S

R

RECORD D

RAW

IN

GS

THIS

D

OCUM

ENT H

AS B

EEN U

PDATED

W

IT

H A S-B

UIL

T IN

FORM

ATIO

N F

URNIS

HED

BY T

HE S

UBCONTRACTORS.

03/2 9/2

EM2 EM2

292929 29

29 29

NL NL

NL

25 25

NL

NL

Building 10663

Building 10667 and 10675 e3ppmrjb Line e3ppmrjb Line e3ppmrjb Line mechanical room in building P-10270. Power is fed from existing gear, 100 amp spare breaker.

2. Furnished and installed a 75 KVA step down transformer in new mechanical room to convert 480v, 100 amps to 208v 200 amps.

3. Furnished and installed 1(ea) 4’ x 8’ x ¾” plywood backboard painted gray for new entrance panel in mechanical room.

4. Furnished and installed 200 amp, 120/208volt, 3 phase, 42-circuit entrance panel in mechanical room.

a. Entrance panel received #4 bare copper ground wire to be clamped to the 5/8”x10’ ground rods.

5. Furnished and installed #4/0 bare copper ground wire and 5/8” ground rods for grounding of pre engineered building columns as per code.

6. Furnished and installed electrical wiring to all electrical circuits and power devices throughout interior and exterior of building to in such a manner to meet NEC code.

7. Furnished and installed EMT conduit, boxes, and fittings to include #12 THHN stranded copper wire for wiring outlets, switches, lights, exit and emergency lights in building areas.

8. Furnished and installed # 12/2 Armored cable, EMT and associated boxes and connectors for wiring office and mechanical room lights, switches and receptacles.

9. Furnished and installed new 2’x4’-40w, T-8 drop-in fluorescent ceiling lights in office.

10. Furnished and installed T-5 high output 3 bulb fixtures in training area and mechanical room.

11. Furnished and installed receptacles, switches and covers as per drawing.

12. Furnished and installed 1(ea) LED Exit emergency combo light over each exit door.

13. Furnished and installed 1(ea) exterior light fixture in each exterior canopy.

a. Exterior lighting fixtures shall be 35 watt Metal halide (pulse start). Exterior

a. Pre-engineered building has a 12’ eave with a 3/12 pitch. Building designed with 70lb snow load and 100 mph wind load.

2. Furnished and installed 3” insulated sandwich panels for building sidewalls.

3. Furnished and installed pre-engineered canopies over each training room entrance.

4. Furnished and installed 21(ea) windows. See drawings for locations.

a. Windows are 2’ x 5’, slider type windows. Windows are installed 8’ above the

Building 10675

Building 10680 and 10686

Building 10680

Building 10680 and 10686 mechanical room in building P-10270. Power is fed from existing gear, 100 amp spare breaker.

2. Furnished and installed a 75 KVA step down transformer in new mechanical room to convert 480v, 100 amps to 208v 200 amps.

3. Furnished and installed 1(ea) 4’ x 8’ x ¾” plywood backboard painted gray for new entrance panel in mechanical room.

4. Furnished and installed 200 amp, 120/208volt, 3 phase, 42-circuit entrance panel in mechanical room.

a. Entrance panel received #4 bare copper ground wire to be clamped to the 5/8”x10’ ground rods.

5. Furnished and installed #4/0 bare copper ground wire and 5/8” ground rods for grounding of pre engineered building columns as per code.

6. Furnished and installed electrical wiring to all electrical circuits and power devices throughout interior and exterior of building to in such a manner to meet NEC code.

7. Furnished and installed EMT conduit, boxes, and fittings to include #12 THHN stranded copper wire for wiring outlets, switches, lights, exit and emergency lights in building areas.

8. Furnished and installed # 12/2 Armored cable, EMT and associated boxes and connectors for wiring office and mechanical room lights, switches and receptacles.

9. Furnished and installed new 2’x4’-40w, T-8 drop-in fluorescent ceiling lights in office.

10. Furnished and installed T-5 high output 3 bulb fixtures in training area and mechanical room.

11. Furnished and installed receptacles, switches and covers as per drawing.

12. Furnished and installed 1(ea) LED Exit emergency combo light over each exit door.

13. Furnished and installed 1(ea) exterior light fixture in each exterior canopy.

a. Exterior lighting fixtures shall be 35 watt Metal halide (pulse start). Exterior

a. Pre-engineered building has a 12’ eave with a 3/12 pitch. Building designed with 70lb snow load and 100 mph wind load.

2. Furnished and installed 3” insulated sandwich panels for building sidewalls.

3. Furnished and installed pre-engineered canopies over each training room entrance.

4. Furnished and installed 21(ea) windows. See drawings for locations.

a. Windows are 2’ x 5’, slider type windows. Windows are installed 8’ above the

Building 10686

Building 10690

Block: 10700

10100

10500

11600

11500

10700-1 10600

10000

99000

99100

11700

99400

99300

95000

94400

94200

94500

10700-2

ROAD

³Boundary Fence 0 405 810 1,620 2,430 3,240 Feet

Railroad Road

Parking/Driveway Athletic FieldTHIS MAP BOOK IS PRODUCED BY

PUBLIC W ORKS, MASTER PLANNING

FORT DRUM, NY

Brad Dugger- 772-0438 Date Saved: 11/7/2017

Block: 10700-2

11600

11500

10700-1

10000

11700

10900

95000

94400

94200

94500

10700-2

10800

94100

94000

RD

ST

³Boundary Fence 0 350 700 1,400 2,100 2,800 Feet

Railroad Road

Parking/Driveway Athletic FieldTHIS MAP BOOK IS PRODUCED BY

PUBLIC W ORKS, MASTER PLANNING

FORT DRUM, NY

Brad Dugger- 772-0438 Date Saved: 11/7/2017

Building 10700

Building 10700

Building 10705

10705

Building 10715

10715

Building 10715

Building 10720

Building 10720

Building 10725

File details come from the government source that posted it.