SEAL END OF SEAM
GASKETED FASTENERS
TH. SPRAY APPLIED INSUL. BELOW
TO MATCH ROOF PANEL & W/ CONT. 4"
FLAT PAN ASSEMBLY OF MATERIAL & FINISH
INSUL. METAL ROOF PANEL
OF CONT. SEALANT TAPE
OVERLAPPED JOINT W/ TWO BEADS
6'' MIN. OVERLAP
GASKETED FASTENERS
OF SEALANT
OVERLAPPED JOINT W/ TWO BEADS
PIPE STACK
W/ FLAT PAN ASSEMBLY
SEALED FABRICATED END CAP INTEGRAL
6'' MIN. OVERLAP
IN SEAMS
GASKETED FASTENERS W/ SEALANT
SEAM AND PANEL PROFILES VARY
SEAM AND PANEL PROFILES VARY
CONT. BEAD OF SEALANT
SET SECUREMENT RING IN
FLANGE TO ROOF PANEL
SECURE FLASHING COLLAR
GASKETED FASTENERS TO
FLASHING
PENETRATION
PREFORMED
ROOF PANEL
INSULATED METAL
TO FACILITATE RUNOFF
(E.G., POLYURETHANE) TOOLED
INSTALL APPROPRIATE SEALANT
ST. STL. DRAWBAND
5/8 "
7/8 "
7 5/8 "
9 1/8 "
/8
R O
CONT. XPS INSULATION
CONT. VAPOR BARRIER
HORIZ JOINT REINF
STRUCT DWG
PLATFORM FLOOR SLAB, SEE
REINF CONC & METAL DECKING
EDGE POUR STOP / KICK PLATE
CONT GALV STL PLATE SLAB
HORIZ JOINT REINF
DWG.
CONC. FLOOR SLAB, SEE STRUCT
WALL BASE
SCHEDULED FLOOR FINISH &
FURRING @ 4'-0" OC
VERT GALV. STL HAT CHANNEL
GYP BD W/ PAINTED FINISH
OPENINGS, SEE STRUCT DWG.
REINF CMU BOND BEAM SPANNING
F
IN
IS
H C
E
IL
IN
G H
T T
Y P
BOLLARD, BEYOND
/4
1/2 "
1/2 "
APRON TRIM, SOLID WHITE COLOR.
SOLID SURFACING WINDOW SILL &
SOLID WHITE COLOR.
EXTENDED 2" BEYOND OPENING,
SOLID SURFACING WINDOW SILL
PT BLOCKING
A L
IG
N
CONT. SEALANT & BACKSTOP, TYP.
FURRING @ 4'-0" OC
VERT GALV. STL HAT CHANNEL
GYP BD W/ PAINTED FINISH
PT BLOCKING
SYSTEM
SUSPENDED ACOUSTICAL CEILING
E Q
E Q
E Q
PROVIDE OPENING AT LADDER
W/ POSTS MOUNTED TO SLAB.
EXPOSED PLATFORM SLAB SIDES
CONT STL GUARD RAILS @ ALL
INT LINE OF GIRT = EXT FACE OF CMU
STRUT W/ CONT CLOSED CELL SPF
SEAL INTERIOR SIDE OF INSUL METAL WALL & ROOF PANELS @ EAVE
EAVE STRUT, SEE STRUCT DWGS
BACK
FASTENED TO UNDERSIDE OF OVERHANG FROM ROOF PANEL CUT-
EAVE CLOSURE TRIM, FASTENED TO WALL PANEL BEHIND GUTTER &
4 1/2" MIN
M
IN
@ EAVE W/ CONT CLOSED CELL SPF
SEAL & FILL EXTERIOR JOINT OF INSUL METAL WALL & ROOF PANELS
ST STL HIDDEN FASTENER CLIP SET IN BUTYL SEALANT
MIN 4" x 5" CROSS SECTION
GUTTER W/ 1/4" : 12" SLOPE ALONG LENGTH. LEADER (NOT SHOWN)
ALIGN
CONT. BUTYL TAPE SEALANT
PANEL CLIP & FASTENERS
FASTENER W/ BUTYL SEALING WASHER, TYP
GUTTER HANGER FASTENER W/ BUTYL SEALING WASHER
3"8"
ROOF PURLINS, TYP, SEE STRUCT DWGS
PANELS @ RIDGE W/ CONT CLOSED CELL SPF
SEAL & FILL EXTERIOR JOINT OF INSUL METAL ROOF
LENGTH END JOINTS
EXT SIDE RIDGE TRIM / CAP W/ OVERLAPPING & SEALED
END JOINTS
INT SIDE RIDGE TRIM W/ OVERLAPPING & SEALED LENGTH
RIDGE PURLINS W/ CONT CLOSED CELL SPF, TYP.
SEAL INTERIOR SIDE OF INSUL METAL ROOF PANELS @
CONT CLOSED CELL SPF
RIDGE CLOSURE TRIM W/ ALL GAPS SEALED & FILLED
FASTENER W/ BUTYL SEALING WASHER, TYP
CONT BUTYL SEALANT TAPE BELOW CLOSURE TRIM, TYP
TYP
CONT BUTYL SEALANT TAPE ON TOP OF CLOSURE TRIM,
FASTENER W/ BUTYL SEALING WASHER, TYP
TYP
CONT. BUTYL SEALANT ON TOP OF INT SIDE RIDGE TRIM,
AS PER PANEL MFR
AS PER PANEL MFR
AS PER PANEL MFR
AS PER PANEL MFR
PANEL CLIP & FASTENERS, TYP
RAKE TRIM / FASCIA
AS PER INSUL METAL PANEL MFR REQ
TYP
FASTENER W/ BUTYL SEALING WASHER,
CONT. RAKE CLOSURE TRIM
LOW PROFILE THRU PANEL FASTENER
W/ CONT CLOSED CELL SPF
METAL WALL & ROOF PANELS @ RAKE
SEAL & FILL EXTERIOR JOINT OF INSUL
CONT BUTYL SEALANT MARRIAGE BEAD TO VERT PANEL JOINT
BUTYL SEALANT
ST STL HIDDEN FASTENER CLIP SET IN
TO VERT PANEL JOINT
CONT BUTYL SEALANT MARRIAGE BEAD
LENGTH END JOINTS
OVERLAPPING & SEALED
RAKE ANGLE SUPPORT W/
CLOSED CELL SPF
@ RAKE STRUT W/ CONT
METAL WALL & ROOF PANELS
SEAL INTERIOR SIDE OF INSUL
BEYOND
PURLIN,
ROOF
ANGLE SUPPORT, TYP
TOP OF INT SIDE RAKE
CONT. BUTYL SEALANT ON
W/ AIR / VAPOR / WATER TIGHT INSTALLATION (MIN R-VALUE = 23.25)
VERT INSUL METAL PANEL, FASTENED TO GIRTS. EXT APPLICATION
TO PURLINS, TYP (MIN R-VALUE = 23.25)
AIR / VAPOR / WATER TIGHT INSTALLATION, FASTENED
CONT STANDING SEAM INSUL METAL ROOF PANELS W/
31.0)
WATER TIGHT INSTALLATION, FASTENED TO PURLINS (MIN R-VALUE =
CONT STANDING SEAM INSUL METAL ROOF PANELS W/ AIR / VAPOR /
SEE STRUCT DWG.
SLAB @ TOP, EXCEPT @ OPNG.
WALL TO FLR SLAB & PLATFORM
VERT CONC REINF TYING CMU
SEE STRUCT DWG.
SLAB @ TOP, EXCEPT @ OPNG.
WALL TO FLR SLAB & PLATFORM
VERT CONC REINF TYING CMU
(MIN STC = 55)
& REINF. SEE STRUCT DWG.
CONSTRUCTION, FULLY GROUTED
LOAD BEARING CMU WALL
(MIN. STC = 55)
& REINF. SEE STRUCT DWG.
CONSTRUCTION, FULLY GROUTED
LOAD BEARING CMU WALL
STL WINDOW UNIT HEAD
STL WINDOW UNIT SILL
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
A N
S I
D
W
D S -1
-B -0
W X
X X
X X -X
X -X -X
W A
T E
R V
L
IE
T A
R S
E N
A L
W A
T E
R V
L
IE
T
N Y
G E
N E
R A
L P
U R
P O
S E W
A R
E H
O U
S E
P N
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N E
W Y
O R
K D
IS
T R
IC
T
F
E D
E R
A L P
L A
Z A
N E
W Y
O R
K
N Y
W X
X X
X X -X
X -X -X
M
Y
RTA
EL = 0' 0"
T.O. FLOOR SLAB
EL = 10' 8"
T.O. PLATFORM
EL = 36'-9 1/2"
BO ROOF PANEL @ EAVE
SIGNAGE SPECIFIC INFORMATION.
ON DRAWING SHEET A-503 FOR
SEE SIGNAGE SPECIFIC DETAILS3.
WALL CONSTRUCTION.
DRAWING SHEET A-503 FOR CMU
SEE CMU SPECIFIC DETAILS ON2.
ROOF PANEL.
OF INTERIOR COLOR OF WALL OR
FINISH COLOR TO MATCH COLOR
FROM SAME MANUFACTURER W/
INTUMESCENT THERMAL BARRIER
TO HAVE CODE / AHJ APPROVED
ALL EXPOSED CLOSED CELL SPF1.
SHEET NOTES
ARCHITECTURAL
FOR HOT PIPES, SPECIFIC HIGH-TEMPERATURE BOOTS SHALL BE USED.7.
AND OTHER PROJECTIONS TO FACILITATE PROPER FLASHING AND PROPER DRAINAGE.
VENT STACKS AND OTHER PIPES SHALL HAVE ADEQUATE CLEARANCE ON ALL SIDES FROM WALLS6.
ALONG ITS UPSLOPE END, MAY BE NECESSARY.
IF FIELD PANELS OVERLAP AT THE PENETRATION,ATTACHMENT OF THE DOWNSLOPE PANEL,5.
INSTALLING PREFORMED BOOT THROUGH SEAM.
WHERE PENETRATIONS INTERSECT SEAMS, THIS DETAIL SHALL BE USED RATHER THAN4.
SEE DETAIL 2 OF SHEET A-502 FOR INFORMATION ON PENETRATION FLASHING.3.
PENETRATION.
PROVIDE REQ SEPARATION OF SPRAY APPLIED INSUL BELOW FLAT PAN ASSEMBLY &2.
PROPER STRUCTURAL SUPPORT IS REQUIRED FOR FLAT PAN ASSEMBLY.1.
NOTES:
EQUIPMENT SUPPORT STAND/VENT STACK
(DASHED)
OVERLAP FLASHING COLLAR 3'' MIN.
RAIN COLLAR W/ ST. STL. DRAWBAND -
OPTIONAL WATERTIGHT SHEET- METAL
DRAINAGE.
PANEL
FLASHING &
PROPER
TO FACILITATE
PROJECTIONS
OTHER
FROM WALLS &
ON ALL SIDES
CLEARANCE
ADEQUATE
HAVE
SHALL
OTHER PIPES
STACKS &
NOTE: VENT
DS: S:\Projects\TS_WORKSPACES\AEC_WS_001\Workspace\Extensions\LocalExtension\pltcfg\AEC_Screen.dscript.dscript 7:39:43 PM 7/25/2018
S:\Projects\Watervilet_Arsenal\New_Warehouse\Drawings\ProjectData\CAD_BIM\_Sheets\75906_WVA_Warehs_A-502.dgn
A-502
M J
U R
C
IC
E
C S h e e tS e e d .d g n
M J
U R
C
IC
M J
U R
C
IC
M J
U R
C
IC
SCALE: NTS
GUTTER EXPANSION JOINT: BUTT TYPE
(SMACNA ARCH SHEET METAL MANUAL, 7TH EDITION)
1/8"
1/2"1/2"
2"
SCALE:
1' 2'0 6"
WALL SECTION DETAIL @ INTERIOR & OFFICE WALL
SECTION DETAIL @ ROOF RIDGE
1' 2'0 6" 1' 2'0 6"4 7
5 8
WALL SECT DET @ ROOF RAKE
1' 2'0 6"6
SCALE: NTS
3D DETAIL OF ROOF PENETRATION @ PANEL SEAM
SCALE: NTS
PENETRATION @ PANEL FIELD
3D DETAIL OF ROOF
W A
L L S
E C
T
IO
N D
E T
A
IL
S
SECTION DETAIL @ CANOPY
SCALE: NTS
WALL SECTION DETAIL @ ROOF EAVE W/ GUTTER
J U
L
R E
V
IS
E D I
N A
C C
O R
D A
N C
E W
IT
H A
M E
N D
M E
N T M
J
File details come from the government source that posted it.