Appendix_X_-_Bldg_98_As-builds.pdf
PDF 2 MB Posted
- Solicitation number
- W912DS-17-R-0003
About this file
W912DS-17-R-0003-APPENDIX X
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Description
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-A1
Building # 98
Floor plan
1. Floor
14 Jan. 1999
1/8" = 1’-0"PKR
1 1
101A 103A
102 105
104A 106A
107A 109A
112A 114A
115A 117A
133A 131A
130A 128A
124A 122A
121A 119A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
UP
UP
122 120 118 116 114 112 110 108 106 104 102 100
119 117 115 113 111 109 107 105 103 101
TYPICAL TWO PERSON SUITE
D.F.
UP
U P
U P
U P
U P
1’-3 3/4"
12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" - 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"
1’-3 3/4"
227’-7 1/2"
PLAN, FIRST FLOOR BLDG # 98
98-A1.dwg 5/1/2014 9:31:26 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-A2
Building # 98
Floor plan
2. Floor
14 Jan. 1999
201A 203A
202 205
204A 206A
207A 209A
210A 212A
213A 215A
216A 218A
232A 230A
229A 227A
224A 222A
221A 219A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
UP
DN.
UP
DN.
222 220 218 216 214 212 210 208 206 204 202 200
219 217 215 213 211 209 207 205 203 201
TYPICAL TWO PERSON SUITE
D.F.
UP
DN.
1’-3 3/4"
12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"
227’-7 1/2"
1’-3 3/4"
PLAN, SECOND FLOOR BLDG # 98
98-A2.dwg 5/1/2014 9:32:25 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-A3
Building # 98
Floor plan
3. Floor
19 Jan. 1999
301A 303A
302 305
304A 306A
307A 309A
310A 312A
313A 315A
316A 318A
333A 331A
330A 328A
325A 323A
322A 320A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
DN.
DN.
322 320 318 316 314 312 310 308 306 304 302 300
319 317 315 313 311 309 307 305 303 301
TYPICAL TWO PERSON SUITE
12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"
D.F.
227’-7 1/2"
1’-3 3/4" 1’-3 3/4"
DN.
PLAN, THIRD FLOOR BLDG # 98
98-A3.dwg 5/1/2014 9:33:16 AM
331 21 23 31 2 1 21 2 1 21 2 3 33 3 1 22121 1 2 1 221
123312123312123312123312123312123312
Description
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-S1
Building # 98
Elevation
6 Jan. 1999
1/8" = 1’-0"LMØ
1 198-S1.dwg 5/1/2014 9:44:33 AM
15" 15" 15" 15"
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-S2
Building # 98
Interior elevations and building sections
9 Jan. 1999
1/8" = 1’-0"LMØ
1 198-S2.dwg 5/1/2014 9:45:11 AM
102 105
104A 106A
107A 109A
112A 114A
115A 117A
133A 131A
130A 128A
124A 122A
121A 119A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
UP
UP
122 120 118 116 114 112 110 108 106 104 102 100
119 117 115 113 111 109 107 105 103 101
TYPICAL TWO PERSON SUITE
D.F.
UP
U P
U P
U P
U P
1’-3 3/4"
12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" - 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"
1’-3 3/4"
227’-7 1/2"
PLAN, FIRST FLOOR BLDG # 98
RV-2
1" HHWR-UP
RP-III
RP-II
1" HHWS-UP
FD
FD
FD FD
FD FD
10"x10"
FD FD
26"x10"14"x10"
FD FD
FD
FD
EACH (TYP.)
75 CFM,
8"x4" SAR
10"x6" SAR
FD
FD FD
FD
12"x10"
(TYP)
FD FD
FD
10"x8"
FD
PENETRATIONS
8"x4"SAR
70CFM(TYP)
FD
FD
200 CFM
FD
1…" HHWS
1…" HHWR 12"x10"SAD
26"x10"SAD
FD FD
8"x10"EAD-UP(TYP)
AT ALL FLOOR
PROVIDE F.D.
6"x10"EAR
140 CFM(TYP)
S
SEE PART
PLAN SH.M-5
EAG
RP-II RP-II RP-II RP-II RP-IV RP-II RP-II RP-II
RP-II, SEE TYP.
PIPING DETAILS
SH. M-5
3/4" HHWS (FLOOR BRANCH)
3/4" HHWR (FLOOR BRANCH)
1…" HHWS (MAIN)
20"x16"SAD-UP
RV-I SEE RELIEF
VALVE DETAIL, SHHEET M-5 (TYP)
(BEHIND ACCES PANEL)
TYPICAL BEDROOM
SEE PART PLAN
SHEET M-5
SEE PART PLAN
TYPICAL LOUNGE
SHEET M-5
1 …" HHWS (MAIN)
3/4" HHWR (FLOOR BRANCH)
3/4" HHWS (FLOOR BRANCH)
RP-II RP-II RP-II RP-II RP-II
1…" HHWR
1…" HHWS
1‰"HRS & HHR-UP
1‰"CONDENSATE
3"HPS
RP-II RP-II RP-II RP-II RP-III
1" HHWS-UP
M1
M1
M5
M1
3/4" HHWS (FLOOR BRANCH)
3/4" HHWR (FLOOR BRANCH)
1 …" HHWS (MAIN)
ARCTIC HOOD
TYPE II
EF-2
ARCTIC HOOD
TYPE II
EF-1
3/4" HHWS (FLOOR BRANCH)
3/4" HHWR (FLOOR BRANCH)
1…" HHWS (MAIN)
RUN PIPING
OVER DOOR AND
ABOVE NEW
CEILING
ARCTIC HOOD
INTAKE TYPE
Description
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-M1
Building # 98
Floor plan
1. Floor - HVAC
20 Jan. 1999
1/8" = 1’-0"LMØ/PKR
98-M1.dwg 5/1/2014 9:40:07 AM
302 305
304A 306A
307A 309A
310A 312A
313A 315A
316A 318A
333A 331A
330A 328A
325A 323A
322A 320A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
DN.
DN.
322 320 318 316 314 312 310 308 306 304 302 300
319 317 315 313 311 309 307 305 303 301
TYPICAL TWO PERSON SUITE
12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"
D.F.
227’-7 1/2"
1’-3 3/4" 1’-3 3/4"
DN.
PLAN, THIRD FLOOR BLDG # 98
FD FD FD
FD
8"x6"
FD FD
12"x8"
FDFD
FD
18"x8"
FD
S
FD
20"x8"
FD FD
FD
FD FD
12"x8"16"x8"
FD FD FD FD
8"x6"
FDFD
FD
FD
MEAG
20"x12"
SAD-DN
10"x6"SAR
200 CFM
ARCTIC HOOD
TYPE II
TYPICAL LOUNGE
SEE PART PLAN
SHEET M-5 SHEET M-5
SEE PART PLAN
TYPICAL BEDROOM 3/4"HHWR(FLOOR BRANCH)
3/4"HHWS(FLOOR BRANCH)3/4"HHWS(FLOOR BRANCH)
3/4"HHWR(FLOOR BRANCH)
RP-II RP-II RP-II RP-II RP-II RP-IV RP-II RP-II RP-II RP-II RP-II
8"x4"SAR
75 CFM EACH
ARCTIC HOOD
TYPE I
1‰"HHS-DN
1‰"HHR-DN
RP-IIRP-IIRP-II RP-II RP-II RP-II RP-II RP-II RP-II RP-IIIRP-IIRP-III
3/4"HHWS(FLOOR BRANCH)
3/4"HHWS(FLOOR BRANCH)
1"HHWR-DN
RV-6
3/4"HHWR(FLOOR BRANCH)
3/4"HHWS(FLOOR BRANCH) 1"HHWS-DN
8"x10"EAD
UP & DN(TYP)
10"x6"EAR
140CFM(TYP)
1‰"HRS
1‰"HRR
16"x28"EAD
UP TO ATTIC
FILTER
HRC-3
P-5
EF-7
F O
R
H E
A T
C O
V E
R Y
S Y S
T
M
P
IP
IN
G
D E
T A
IL
S
S
E
RV-5
1"HHWR-DN1"HHWS-DN
EF-5
ARCTIC HOOD
EF-6
TYPE II
Description
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-M3
Building # 98
Floor plan
3. Floor - HAVC
25 Jan. 1999
98-M3.dwg 5/1/2014 9:40:29 AM
HOT WATER (HG-1)
GENERATOR
(SEE DETAIL
15-M1 AND
GEN. NOTE 1
SHT. M7
INV EL 169.83’
2"VR
4"
CONVERTER (C-1)
(SEE DETAIL
15-M2)
SEE GEN. NOTE 1
SHT. M-7
DUPLEX CONDENSATE
UNIT-PUMPS 9 GAL.
@ 20 PSI, 1/3 HP
(120/1/60) 3500 RPM
RECEIVER 14 GAL.
2"VR
4"
1‰" VENT
TO OUTSIDE
AIR RELEASE
TANK
1…" HHWS
CP-1
PRESSURE
REDUCING STATION
SEE DETAIL THIS SHEET
SAFETY RELIEF
VALVE
4" SIGHT
DRAIN
FULL SIZE
VENT TO FL.
1…" HHWR
HW CIRC. PUMP
SEE NOTE 1
2" 2"
1"
1…"
CW
1…" HHWR
L P
S H H
W R
CO
C
E x D
TANK
H H
W S
1‰"
2"
4"SS
FLASH TANK
THULE AIR BASE
Review:
Approv.:
Design:
Drawn:
Description:
Rev. Date Init.
Sheet: of Date:
Dwg. No.:
Scale:
Description
98-M5
Building # 123
Plan
Plan and Sections
1/8" = 1’-0"
01. Oct. 2000
98-M5.dwg 5/1/2014 9:42:39 AM
102 105
104A 106A
107A 109A
112A 114A
115A 117A
133A 131A
130A 128A
124A 122A
121A 119A
UP
UP
122 120 118 116 114 112 110 108 106 104 102 100
119 117 115 113 111 109 107 105 103 101
TYPICAL TWO PERSON SUITE
D.F.
UP
U P
U P
U P
U P
126 118
PLAN, FIRST FLOOR BLDG # 98
4"
R
R
P-3 P-3
P-1 P-2
P-7
2" VS
" CW-UP4
" HW-UP4
2" WS4"S
2"
3"
2"V CO
4" S DROP THRU FL
1‰" W&V
4" VS
‰" HW-UP
1" CW-UP
4" SS
TYP
FOR 6
FOR 6
TYP
CO
CO
P-2 P-1CO
P-7
CO
R
P-3 P-3
R
4"
INV. EL.173.83’4" S DROP THRU FL
P-3 P-3
4" VS
‰" HW-UP
1" CW-UP
4" SS
2"V P-1 P-2
3" P-7
1‰" W&V
CO
4"S
FOR 3
TYP
R
P-3
2"
P-3
2" VS
" CW-UP4
" HW-UP4
2" WS
R
TYP
FOR 3
P-1 P-2
CO
P-7
CO
R
P-3 P-3
R
P-1
P-2
CO
P-7
CO
R
P-3 P-3
R
P-1
P-2CO
P-7
CO
R
P-3 P-3
R
4"S-SEE SHT. C-1
INV. EL. 173.0’
1‰" FL-UP
FHC
4"S DROP
THRU FL.
INV. EL.173.83’
4" S DROP THRU FL
4" S DROP THRU FL
CO
4"
4"S DROP
THRU FL.
CO
PLAN-SHT. M-5
MECH. RM.-SEE PART
2"VR 4"V.S
4"SS 1‰"VR
2"VS
4"S
1‰"W
2"WS
3"DROP THRU FL.
R
INV. EL.173.83’
INV. EL.173.83’
2‰"FL-UP
3"CW-UP
1"HWR-UP
2"HW-UP
CO
R
2"S
1‰" FL-UP
INV. EL. 173.0’
4"S-SEE SHT. C-1
CO
FHC
R R
P-2 P-7
P-3
CO
P-1
P-3
CO
4"
R R
P-2
P-7
P-3
CO
P-1
P-3
CO
INV. EL.173.83’
R R
P-2
P-7
P-3
CO
P-1
P-3
CO
4" S DROP THRU FL
‰" HW-UP
‰" CW-UP
2" VS
2" WS
R
P-8 ‰" CW-UP
2" WS
2" WS
3" V.S.
2" W&V
2" W&V
3" W.S.
2" W&V
1" HW-UP
1" CW-UP
3" W-2"V
INV. EL.173.83’
CO
P-5
P-6
P-9
P-9
WCO
R
CO
SHT. M-5
SEE PART PLAN
CO
P-4
R
Description
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-M6
Building # 98
Floor plan
1. floor plumbing
21 Jan. 1999
1 198-M6.dwg 5/1/2014 9:43:15 AM
201A 203A
202 205
204A 206A
207A 209A
210A 212A
213A 215A
216A 218A
232A 230A
229A 227A
224A 222A
221A 219A
UP
DN.
UP
DN.
222 220 218 216 214 212 210 208 206 204 202 200
219 217 215 213 211 209 207 205 203 201
TYPICAL TWO PERSON SUITE
D.F.
UP
DN.
PLAN, SECOND FLOOR BLDG # 98
R
P-3
R
4" SS
1 …" CW-DN, 1" CW-UP
" HW-DN, ‰" HW-UP4
4" V.S
TYP
2" V.S.
" CW-DN, ‰" CW-UP4
" HW-DN, ‰" HW-UP4
2" W.S
TYPP-7
P-3
AP
P-1 P-2
1‰"
3/4"
3/4"
3/4"
3/4" 1…"
P-3
R
3/4"
2‰" 2"
3/4"
AP
1‰"
P-1 P-2
P-3
P-7
R
1…"
2" FL-DN, 1‰" FL-UP
FHC
P-3
1‰"
R
3/4"
3/4"
1‰"
AP
1‰"
P-2 P-1
P-3
P-7
R
3/4"
1"
P-3
P-2
1…"
AP P-1
1‰"
P-3
R 3/4"
2"W.S.
3/4"
P-7
R
P-8
R P-3
P-7
R
3/4" P-2
P-3
1‰"
P-1 3/4"
R
2"
AP 1…"
1" 1‰"
R
3/4"
P-7
P-3P-3
P-2
1‰"
AP
P-1
3/4"
1"
R
1"
1‰"
3/4"
P-1
3/4"
R
P-2
1…"
AP P-7
R
P-3 P-3
3/4"
P-1 3/4"
R
P-2
1‰"
AP
P-7
R
P-3 P-3
3/4"
P-1 3/4"
R
P-2
1‰"
AP
P-7
R
P-3 P-3
3/4"
P-1 3/4"
FHC
R
P-2
1‰"
AP
P-7
R
P-3 P-3
2‰" 2"
2" 1"
‰" CW-UP & DN
2"VS
R
2" V.S.
" CW-DN, ‰" CW-UP4
" HW-DN, ‰" HW-UP4
2" W.S
2"
1…"
M-5
M-5
1‰"
2‰"
2‰"
2"
1"
3"
BV
2‰"
1‰"
BV
3/4" P-4
HW-UP"3/42" HW-DN,
1" HWR-DN
CW-UP"3/43" CW-DN,
2‰" FL-DN
P-6
P-9
P-9
P-5
1‰"
1‰" 2‰"
1…" 1…"
R
1…" HW-DN, 1" HW-UP
1…" CW-DN, 1"CW-UP
3" WS
3" VS
2"
2" FL-DN, 1‰" FL-UP3/4"
1‰"
1" 1…"
2" 1…"
2"
3/4"
3/4"1‰" 3/4"
Description
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-M7
Building # 98
Floor plan
2. floor plumbing
21 Jan. 1999
98-M7.dwg 5/1/2014 9:43:38 AM
302 305
304A 306A
307A 309A
310A 312A
313A 315A
316A 318A
333A 331A
330A 328A
325A 323A
322A 320A
DN.
DN.
322 320 318 316 314 312 310 308 306 304 302 300
319 317 315 313 311 309 307 305 303 301
TYPICAL TWO PERSON SUITE
D.F.DN.
PLAN, THIRD FLOOR BLDG # 98
FD FD FD
FD
8"x6"
FD FD
12"x8"
FDFD
FD
18"x8"
FD
S
FD
20"x8"
FD FD
FD
FD FD
12"x8"16"x8"
FD FD FD FD
8"x6"
FDFD
FD
FD
MEAG
20"x12"
SAD-DN
10"x6"SAR
200 CFM
ARCTIC HOOD
TYPE II
TYPICAL LOUNGE
SEE PART PLAN
SHEET M-5 SHEET M-5
SEE PART PLAN
TYPICAL BEDROOM 3/4"HHWR(FLOOR BRANCH)
3/4"HHWS(FLOOR BRANCH)3/4"HHWS(FLOOR BRANCH)
3/4"HHWR(FLOOR BRANCH)
RP-II RP-II RP-II RP-II RP-II RP-IV RP-II RP-II RP-II RP-II RP-II
8"x4"SAR
75 CFM EACH
ARCTIC HOOD
TYPE I
1‰"HHS-DN
1‰"HHR-DN
RP-IIRP-IIRP-II RP-II RP-II RP-II RP-II RP-II RP-II RP-IIIRP-IIRP-III
3/4"HHWS(FLOOR BRANCH)
3/4"HHWS(FLOOR BRANCH)
1"HHWR-DN
RV-6
3/4"HHWR(FLOOR BRANCH)
3/4"HHWS(FLOOR BRANCH) 1"HHWS-DN
8"x10"EAD
UP & DN(TYP)
10"x6"EAR
140CFM(TYP)
1‰"HRS
1‰"HRR
16"x28"EAD
UP TO ATTIC
FILTER
HRC-3
P-5
EF-7
F O
A
C O
V E
R Y
S Y S
T
P
IP
IN
G
D E
T A
IL
S
S
E E
T
M
RV-5
1"HHWR-DN1"HHWS-DN
EF-5
ARCTIC HOOD
EF-6
TYPE II
Description
THULE AIR BASE
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-M8
Building # 98
Floor plan
3. floor - plumbing
25 Jan. 1999
98-M8.dwg 5/1/2014 9:43:59 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-E1.1
Building # 98
Floor plan
1. Floor,, Light
25 Nov. 2002
1/8" = 1’-0"TB
(ALL LIGHT FIXTURES ON THIS LEVEL SUPPLIED
FROM "LP1" UNLESS OTHERWISE NOTED).
TO 2ND FLOOR
‰"C-3 NO. 10 UP
STAIR LTS.
J C1C1
J
Sawk awk
J1
H1
HOAce
S3cd
J2
X2 ce cd
J
L1
X2
S3cd
Y1
S
J2 cd
Sk
Sa a Sb
JJ
SHEET(TYP)
DIAGRAM THIS
SEE WIRING
cb A2 by
J cc
M9
G1
J Scb
Scc c b
Sc
L1 J d cb
C1
A2
G1
L1J
Sca
C1 by
J ca
(TYP)
SEE NOTE 6
Sd
Se e
M1 b
A2 J J
A2 d
M1
M9
M3 J
C1C1 J
Sbw
J
LGT. HEADS
REMOTE EMERGENCY
G1
Sby M9 J bx
J
Sbx
Sf f
Y2
M9 bp
G1
J
Sg g h
L1 2 Sh
J J bv A2 br
Sbt
C1
Sbv bv
A2
G1
J
J
L1
Sj
J j
C1 br bt
Sbr
J
G1
Sm l
Sm
(SEE WIRING DIAGRAM THIS SHEET)
‰"C-2 NO.10 TO BATTERY PACK
A2
IN MECH. ROOM 110
M1 A2
J g
J j
M1 J
C1C1 J
STAIR LGT.
TO 2ND FLOOR
‰"C-3 NO.10 UP
FROM PANELBOARD
STAIR LTG. IS SUPPLIED
CKT. LP1-17
SEE NOTE 5
Y1 bp
Sbp
J
G1
Sn m 3 n
J
J1 p
Sp
L1 3 J r
Sr
J2
Y2
J X2
Sk
G1
J
X3
BATTERY PACKS
FOR REMOTE
EMERG.LT.HEADS
S2 t
G1
J
LP1-11
Y2
J
D1 v n
3A2 J J
A2 r
LT. DISC. SW. (TYP)
D1
S3v
‰"C-3 NO.10 TO EXIT
M3
D1
J w
HOaw v
H1 12
X2
S3n
Saj
Sac
J
LTG. HEADS
REMOTE EMERG.
‰"C-2 NO.10 TO
BATTERY PACK IN
MECH. RM. 110
C14
JJ
Sy
G1 11
J v
LP1
S3v v
J
G1 11
Sx x
Saa
G1
J
J y aa
Y211 G1
Sab ab
L1
D1
D1 v
L1 4
4K1
K1 y
J M5
A2 ab
J
C1C1
JJ
C1
A2
M7
11 G1 ad ac J
Sad ax J
Sax
J
C1
Saw aw
Sae ae
JJ
aw A2 at av Sav
J
G1
JL1
C1 at Sat
Saf af Sag
J ar
M7
G1
J
Sar
Sk ah
L1 ag
Sah
J aj
M5J A2 ad
6 A2 M5 ag
J J aj
6A2
NOTEDJ
ABOVE CEILING
8"x8"WIREWAY
STAIR, SEE NOTE 5(TYP)
2ND FLOOR STAIR LTS.
‰"C-3 NO. 10 UP TO
J
S1 ap
HOAap
J2 an
X2
J1
Sk am S3
J2 an
Y1
S3an
Sam al
Sal
L1 14
(TYP)
‰"C-TYPICAL
UNLESS OTHERWISEM5
CORRIDOR-
SEE NOTE 5
101A 103A
102 105
104A 106A
107A 109A
112A 114A
115A 117A
133A 131A
130A 128A
124A 122A
121A 119A
UP
UP
122 120 118 116 114 112 110 108 106 104 102 100
119 117 115 113 111 109 107 105 103 101
TYPICAL TWO PERSON SUITE
D.F.
UP
U P
U P
U P
U P
126 118
98-E1.1.dwg 5/1/2014 9:36:39 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-E1.2
Building # 98
Floor plan
1. Floor, Power
26 Nov. 2002
30A DISC. SW. IN MECH. ROOM # 110
1…"C-8 NO. 8 PWR & 1 NO. 8 GND TO
CKT-23
UNIT HTR
ELECTRIC
DISC. SW.(TYP)
250V, 30A UNFUSED
EUH-3
PP1A-3
J
10 12
12 GFI
GFI
GFI
CKT-19
1"C-3
NO. 8
CKT-22
J
NO. 8
1"C-5
CKT-21
J
GFI
5 5
CKT-20
1"C-5
NO. 8
J
1…"C-7
NO. 8
J
GFI6
GFI
1 1
GFI
GFI 11
CKT-17
SEE NOTE 6
CKT-18
1…"C-7
NO. 8
J
NO. 8
1"C-5
P2-42
J
SEE SHEET E-7
(RUN EXPOSED UNDER FLOOR)
PP1-14,15
EUH
PP1A-2
GFIGFI
13 34
EUH-1
CKT-16
GFI
"PP1"
FEED FROM PANELBOARD
NEW-HEADBOLT HEATERS
CKT-14
P2-42
CKT-13
J
5#8
EF-2
J
PP1-13
CKT-15
3#8
J
3#8
J
GFI
GFI
ELECTRICAL CLOSET ABOVE
36 23 19
GFI
OTHERWISE NOTED.
NO. 10 UNLESS
ALL WIRING SHOWN ON
THIS SHEET SHALL BE
22 GFI
31 31
GFI 22
PP1A-1
29 29
GFI
GFI
UNLESS OTHERWISE NOTED
THIS SHEET SHALL BE
ALL WIRING SHOWN ON
‰"C-TYPICAL
PLAN SHEET E-7
SEE ENLARGED
MECH. RM.
8"X9" WIREWAY RUN
LENGTH OF CORRIDOR
ABOVE HUNG CEILING
OTHERWISE NOTED
NO. 10 AWG UNLESS
101A 103A
102 105
104A 106A
107A 109A
112A 114A
115A 117A
133A 131A
130A 128A
124A 122A
121A 119A
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19
A
B
C
D
UP
UP
122 120 118 116 114 112 110 108 106 104 102 100
119 117 115 113 111 109 107 105 103 101
TYPICAL TWO PERSON SUITE
D.F.
UP
U P
U P
U P
U P
1’-3 3/4"
12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" - 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"
1’-3 3/4"
227’-7 1/2"
98-E1.2.dwg 5/1/2014 9:37:07 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-E2.1
Building # 98
Floor plan
2. Floor, Light
BATTERY PACK IN 225
FOR LIGHTING LAYOYT THIS
AREA, SEE PART PLAN
SHEET E-7
‰"C-2 NO.10 TO
ELECTRICAL CLOSET
SEE SHEET E-5
J2
‰"C-3 NO. 10 DN
TO 1ST FLOOR
STAIR LTS.
‰"C-3 NO. 10 UP
TO 3RD FLOOR
STAIR LTS.
ALL LIGHT FIXTURES ON THIS LEVEL SUPPLIED
FROM "LP2" UNLESS OTHERWISE NOTED.
J
J
STAIR LTG. IS SUPPLIED
FROM PANELBOARD
LP1-15, SEE NOTE 5
C1
Y1
J2
Y1
LP1-15
Sa
LP1-15
Sk X1
JM1
a
Sb
2L1 g
M9 J
Sgj
G1
J
Scc c J
L1
JA2
gj gj
C1
J
A2 J bg bh Sbh bg
C1
G1
J
Se
J b b
Sc
2A2 J
2C1 d d
A2 2
M1
Sd
J e
17H1
3/4" CONDUIT CONNECT
EXIST. FIXTURE
‰"C-3 NO. 10
UP TO 3RD FLOOR
STAIR LTS.
STAIR LTG. IS
SUPPLIED FROM
PANELBOARD LP1-17
SEE NOTE 5
J dd Y1
‰"C-3
NO.10 DN.
M3 A2
Sbe
L1 2
Sbg
J bf
M9
G1
J
Sbf be
M9
Y2 G1
J h
‰"C-2 NO. 10 TO
BATTERY PACK IN 225
M1
G J g
A2
Sg C1
J J g
Sh
Sbc
C1
J Sbd bd A2 J bd
L1J
J
G1
J
J A2 bb bc bb
C1
J Sbb
Sl
G1
SjC1 j j
M2 J l
‰"C-2 NO.10 TO EXIT
LT DISC. SW. IN 1ST
FLOOR MECH. ROOM
(TYP)
G1
J2
L1 4 ba
M9
X1
Sba
J
Sm
G1
Sdd
E1
J
J p J
J m C1Sn n
A2 J J
Sp n
4 A2
C1 4 r r
Sr
Y2
BATTERY PACKS FOR
REMOTE EMERG. LTG.
HEADS
J
St
S3
X2
J Y2
LP2-11
G1
J
11 Y2
Sv
M3 J t
M3 v J
Sw
J J
55 W FIXTURE ‰"C-3 NO. 12
UP TO 3RD FLOOR
STAIR LTS.
Sc
J
M1 4
G1
LP2
J x J
J ay
M7
J
G1 11
Say
Sg
C1 4 w w
A2 4
J J
Sx
C1 y
A2 4 y
Sy
M3 J a3
L1
S2a aw
A2
Sax
C1 ax J J
L1J ax
Saw
G1
J av
A2
C1 av
J Sav
11 G1
M5
2a C1 Sab
J J ab ab
A2 6
CORRIDOR-
SEE NOTE 5
‰"C-2 NO.10 TO
BATTERY PACK IN 225
M7 au
M7
Sau ac J
G1
J at A2
C1
Sar ar
J Sat
Sae
Y2
M5 ad
J
C1 ad
A2 6
Sad
J ae
L1
A2ar
J J
Sap
JL1
ap an an
C1
San
J
G1 11
Saf
M7 am J ah
G1
J
Sam
J
A2
M5 af J
Sag C1
J J ag ag
Sah
C1 aj aj
A2
DN TO 1ST FLOOR
J
STAIR LTS.
‰"C-3 NO. 10
ALL WIRING SHOWN ON
THIS SHEET SHALL BE
NO.10 AWG. UNLESS
OTHERWISE NOTE.
STAIR LTG. IS SUP-
PLIED FROM PANELBOARD
LP1-16, SEE NOTE 5.
LP1-16
LP1-16
J2 Y1
Sk
X1
Sal
J2 ayk
Y1
M5
Saj
J al
201A 203A
202 205
204A 206A
207A 209A
210A 212A
213A 215A
216A 218A
232A 230A
229A 227A
224A 222A
221A 219A
UP
DN.
UP
DN.
222 220 218 216 214 212 210 208 206 204 202 200
219 217 215 213 211 209 207 205 203 201
TYPICAL TWO PERSON SUITE
D.F.
UP
DN.
PLAN, SECOND FLOOR BLDG # 98
98-E2.1.dwg 5/1/2014 9:38:01 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-E2.2
Building # 98
Floor plan
2. Floor, Power
SEE PART PLAN
12 GFI
5 GFI
GFI
ALL RECEPTACLES SHOWN ON
NOTE:
SEE NOTE 6
EF-3
SHEET E-7
GFI
6 6
GFI
GFI
GFI
GFI 11
P2-42
GFIGFI
ELECTRICAL
THIS SHEET
PART PLAN
CLOSET SEE
UNLESS OTHERWISE
‰"C-TYPICAL
ELECTRIC RANGE
EF-4
THIS SHEET SHALL BE
ALL WIRING SHOWN ON
OTHERWISE NOTED.
NO. 10 UNLESS
GFI
PANELBOARD "LP2"
P2-42
TO PNL PP2A
1"C-4 NO. 6
DP2A-15
GFI
GFI
PANELBOARD "DP2A"
GFI
GFI 28
OF CORRIDOR ABOVE HUNG CEILING.
8"x8"WIREWAY RUN LENGTH
GFI
PANELBOARD "P2"
22 GFI
GFI
29 GFI
GFI
NOTED.
CONNECTED TO PANELBOARD "P2"
2.nd FLOOR PLAN ARE
UP
DN.
UP
DN.
UP
DN.
98-E2.2.dwg 5/1/2014 9:38:31 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-E3.1
Building # 98
Floor plan
3. Floor, Light
5. KEY OPERATED SWITCHES SHALL BE PROVIDED FOR ALL CORRIDOR AND
LOCATIONS, SEE REFLECTED CEILING PLANS SHOWN ON ARCHITECTURAL
4. LIGHTING FIXTURES ARE SHOWN DIAGRAMMATICALLY ONLY. FOR EXACT
3. FOR ROOM NAME/NUMBER SCHEDULE, SEE ARCHITECTURAL DRAWING
2. FOR PANELBOARD SCHEDULES, SEE SHEET E-12
1. FOR SYMBOLS AND GENERAL NOTES AND FIXTURE SCHEDULE, SEE SHEET E-1
DIAGRAM SHEET E-3
LP3-11, SEE WIRING
DRAWINGS.
STAIR LIGHTING.
C1
LP1-15, SEE NOTE 5
FROM PANELBOARD
STAIR LTG. IS SUPPLIED
‰"C-3 NO. 10 DN
SUPPLIED FROM "LP3" UNLESS
ALL LGT FIXTURES ON THIS LEVEL
OTHERWISE NOTED
M1 bn bn bm
M9 J
Sbj bj
C1
A2 J bj A2 J bg bg
A2
LP1-15
J2 X2
Sbn
M1
Sk
Sa
M1 1 a J
Sb C1
J
G1
Sbm
J
L1 2 c
Sc b b
J
J
C1
A2 d d
Sbh
L1J
G1
J bh
Sd
M1 J
Se e
LGT. HEADS
REMOTE EMERG.
J Sbg M9 bf
M9 J be J
C1
A2
Sbd bd bd
J bb
A2 bb
C1
Sbb
J
A2
J
Sbe
G1
J Sbf
M1
Sf f J
11Y2
J
G1
Sg
A2 g
2C1
L1 Sh h
J g
J
BATTERY PACK IN 326
‰"C-2 NO. 10 TO
bc
J
J
L1
Sbc
G1
Sj j
C1 j
J
M1
11 G1
Sl l
M3
‰"C-3 NO. 10 DN
SEE NOTE 5
PANELBOARD LP1-17
SUPPLIED FROM
STAIR LTG. IS
M9 ba ma
J
E1 13
NOTE:
HEADS
REMOTE EMERG. LTG.
BATTERY PACKS FOR
(TYP)
FLOOR MECH. ROOM
LT DISC. SW. IN 1ST
‰"C-2 NO.10 TO EXIT
J2
G1
X2
Sba
J
Sma
G1
Sn
Sm m J
C1 n
4A2 n
J
C1 p
L1 Sp
J
J J A2 r r
Sr
Y2
S3
J
X2
Y2
J
St
M3 J t
J
G1 11 u
M3
Su
J Sw
Sam
Sac
BATTERY PACK IN 225
ay
M7 J
A2 axSax
A2 J ax
J
Sav av av
J
G1
J
J
LP3
M1
A2 w
4C1 w
Sx x J
A2 J y
C1
G1
J Say
Sy y
Sy y
M3 J
SEE SHEET E-6
ELECTRICAL CLOSET
Saa
J
L1J
J
Saw aw
G1
M5 aa
Y2
J
G1
C1 Sab
L1
A2 ab ab
J
‰"C-2 NO.10 TO
as
M7 M7 au at J
Sas as
A2 J J A2 ap ap
Sap M7
J an
M5
Sau
11 G1 ad
J ac
J A2 ad
C1 6 Sad
J
Sat
J
Sae ae
A2
J
Sar
L1J ar
G1 11
Saf
M5 af J
Sag C1
J
G1
San
M1 Sah ah ag ag
JJ
J aj
C1
A2 aj
LP1-16 SEE NOTE 5.
FROM PANELBOARD
STAIR LTG. IS SUPPLIED
‰"C-3 NO. 10
DN TO 1ST FLOOR
M1 am am
STAIR LTG.
OTHERWISE NOTED
‰"C-TYPICAL UNLESS
ABOVE CEILING
8"x8" WIREWAY
LP1-16
M1 12
X2 Sk
J2
Sal
Saj
M5 J al
UNLESS OTHERWISE NOTED
SHEET SHALL BE NO. 10 AWG.
ALL WIRING SHOWN ON THIS
301A 303A
302 305
304A 306A
307A 309A
310A 312A
313A 315A
316A 318A
333A 331A
330A 328A
325A 323A
322A 320A
DN.
DN.
322 320 318 316 314 312 310 308 306 304 302 300
319 317 315 313 311 309 307 305 303 301
TYPICAL TWO PERSON SUITE
D.F.DN.
PLAN, THIRD FLOOR BLDG # 98
98-E3.1.dwg 5/1/2014 9:39:01 AM
Review:
Drawn:
Design:
Description:
DateRev. Init.
Approv.: Scale:
Date:
Dwg. No.:
Sheet: of
98-E3.2
Building # 98
Floor plan
3. Floor, Power
PANELBOARD "P3"
PANELBOARD "DP3A"
PANELBOARD "LP3"
ELECTRIC RANGE
GFI
GFI
GFI
GFI 3
1 3
P3-42
6 GFI
GFI
EF-5
GFI
GFI
11 11
GFI
DP2A-15
P3-42
1"IMC 4 NO.6
TO PNL DP3A
GFI
GFI GFI
EF-6
GFI
GFI
8"x8"WIREWAY RUN LENGTH
OF CORRIDOR ABOVE HUNG CEILING.
25 25
GFI GFI
GFI22
GFI
20 18
29 29
GFIGFI
NOTED.
OTHERWISE NOTED
UNLESS OTHERWISE
‰"C-TYPICAL
NO. 10 AWG UNLESS
THIS SHEET SHALL BE
ALL WIRING SHOWN ON
PROTECTION 208Y,
MOTOR CIRCUIT
DISCONNECT SWITCH WITH
COMBINATION MAGNETIC
PUMP P5 DP3A-10
HOT WATER CIRCULATING
DP3A-II
EXHAUST FAN EF-7
208y, 3 POLE
NEMA SIZE 1
MOTER STARTER AND
301A 303A
302 305
304A 306A
307A 309A
310A 312A
313A 315A
316A 318A
333A 331A
330A 328A
325A 323A
322A 320A
DN.
DN.
322 320 318 316 314 312 310 308 306 304 302 300
319 317 315 313 311 309 307 305 303 301
D.F.DN.
98-E3.2.dwg 5/1/2014 9:39:40 AM
THIS PAGE INTENTIONALLY LEFT BLANK
File details come from the government source that posted it. Updated .