About this file

W912DS-17-R-0003-APPENDIX X

View the file

Other files

File Type Posted
W912DS-17-R-0003-AMENDMENT_0001.pdf PDF
Appendix_R_-_Geotechnical_Investigations.pdf PDF
Appendix_E_-_Spill_Prevention-Response_Plan.pdf PDF
Appendix_S_-_Pacer_Goose_Shipping_Instructions.pdf PDF
Appendix_C_-_Natural_Resources_Management_Plan.pdf PDF
Appendixs_CC_-_Product_Data_Sheets.pdf PDF
Appendix_G_-_Solid_Waste_Mgmt_Plan.pdf PDF
Appendix_Z_-_Fuel_Pricing_and_DLA_Instructions.pdf PDF
Appendix_V_-_Exterior_Building_Photos.pdf PDF
Appendix_I_-_Slug_Mgmt_Plan.pdf PDF
Appendix_J_-_Installation_HAZMAT_Management_Plan.pdf PDF
Package_1_-_RFP_Bldg_98_Renovation.pdf PDF
Appendix_U_-_Thule_Facilities_Excellence_Plan_2012.pdf PDF
Appendix_M_-_PCB_Repl_Plan.pdf PDF
Appendix_W_-_Existing_Site_Utilities.pdf PDF
Appendix_F_-_PPM_Plan.pdf PDF
Appendix_B_-_NFS_Material_Borrow_Site.pdf PDF
Appendixs_AA_-_Preliminary_Code_Analysis.pdf PDF
Appendix_A_-_Active_Landfills.pdf PDF
Appendix_T_-_DBA_Waiver.pdf PDF
Appendix_P_-_Unaccompanied_Housing_Design_Guide.pdf PDF
Appendix_O_-_Lead_Paint_Mgmt_Plan.pdf PDF
Appendixs_EE_-_CID_Package.pdf PDF
Appendix_Q_-_FY17_Sealift_Rates.pdf PDF
Appendix_Y_-_Asbestos_Survey.pdf PDF
Appendix_D_-_HWM_Plan.pdf PDF
Appendix_L_-_Affirmative_Proc_Plan.pdf PDF
Appendix_K_-_FGS-GL_(Environmental_Protection).pdf PDF
Appendix_N_-_Asbestos_Mgmt_Plan.pdf PDF
Appendixs_BB_-_Bldg_98_Concept_Drawings_and_Elevations.pdf PDF
Appendixs_FF_-_Thermistor_Profile.pdf PDF
Appendix_H_-_Storm_Water_Mgmt_Plan.pdf PDF
W912DS-17-R-0003-SOLLICITATION.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Description

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-A1

Building # 98

Floor plan

1. Floor

14 Jan. 1999

1/8" = 1’-0"PKR

1 1

101A 103A

102 105

104A 106A

107A 109A

112A 114A

115A 117A

133A 131A

130A 128A

124A 122A

121A 119A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

UP

UP

122 120 118 116 114 112 110 108 106 104 102 100

119 117 115 113 111 109 107 105 103 101

TYPICAL TWO PERSON SUITE

D.F.

UP

U P

U P

U P

U P

1’-3 3/4"

12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" - 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"

1’-3 3/4"

227’-7 1/2"

PLAN, FIRST FLOOR BLDG # 98

98-A1.dwg 5/1/2014 9:31:26 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-A2

Building # 98

Floor plan

2. Floor

14 Jan. 1999

201A 203A

202 205

204A 206A

207A 209A

210A 212A

213A 215A

216A 218A

232A 230A

229A 227A

224A 222A

221A 219A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

UP

DN.

UP

DN.

222 220 218 216 214 212 210 208 206 204 202 200

219 217 215 213 211 209 207 205 203 201

TYPICAL TWO PERSON SUITE

D.F.

UP

DN.

1’-3 3/4"

12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"

227’-7 1/2"

1’-3 3/4"

PLAN, SECOND FLOOR BLDG # 98

98-A2.dwg 5/1/2014 9:32:25 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-A3

Building # 98

Floor plan

3. Floor

19 Jan. 1999

301A 303A

302 305

304A 306A

307A 309A

310A 312A

313A 315A

316A 318A

333A 331A

330A 328A

325A 323A

322A 320A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

DN.

DN.

322 320 318 316 314 312 310 308 306 304 302 300

319 317 315 313 311 309 307 305 303 301

TYPICAL TWO PERSON SUITE

12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"

D.F.

227’-7 1/2"

1’-3 3/4" 1’-3 3/4"

DN.

PLAN, THIRD FLOOR BLDG # 98

98-A3.dwg 5/1/2014 9:33:16 AM

331 21 23 31 2 1 21 2 1 21 2 3 33 3 1 22121 1 2 1 221

123312123312123312123312123312123312

Description

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-S1

Building # 98

Elevation

6 Jan. 1999

1/8" = 1’-0"LMØ

1 198-S1.dwg 5/1/2014 9:44:33 AM

15" 15" 15" 15"

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-S2

Building # 98

Interior elevations and building sections

9 Jan. 1999

1/8" = 1’-0"LMØ

1 198-S2.dwg 5/1/2014 9:45:11 AM

102 105

104A 106A

107A 109A

112A 114A

115A 117A

133A 131A

130A 128A

124A 122A

121A 119A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

UP

UP

122 120 118 116 114 112 110 108 106 104 102 100

119 117 115 113 111 109 107 105 103 101

TYPICAL TWO PERSON SUITE

D.F.

UP

U P

U P

U P

U P

1’-3 3/4"

12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" - 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"

1’-3 3/4"

227’-7 1/2"

PLAN, FIRST FLOOR BLDG # 98

RV-2

1" HHWR-UP

RP-III

RP-II

1" HHWS-UP

FD

FD

FD FD

FD FD

10"x10"

FD FD

26"x10"14"x10"

FD FD

FD

FD

EACH (TYP.)

75 CFM,

8"x4" SAR

10"x6" SAR

FD

FD FD

FD

12"x10"

(TYP)

FD FD

FD

10"x8"

FD

PENETRATIONS

8"x4"SAR

70CFM(TYP)

FD

FD

200 CFM

FD

1…" HHWS

1…" HHWR 12"x10"SAD

26"x10"SAD

FD FD

8"x10"EAD-UP(TYP)

AT ALL FLOOR

PROVIDE F.D.

6"x10"EAR

140 CFM(TYP)

S

SEE PART

PLAN SH.M-5

EAG

RP-II RP-II RP-II RP-II RP-IV RP-II RP-II RP-II

RP-II, SEE TYP.

PIPING DETAILS

SH. M-5

3/4" HHWS (FLOOR BRANCH)

3/4" HHWR (FLOOR BRANCH)

1…" HHWS (MAIN)

20"x16"SAD-UP

RV-I SEE RELIEF

VALVE DETAIL, SHHEET M-5 (TYP)

(BEHIND ACCES PANEL)

TYPICAL BEDROOM

SEE PART PLAN

SHEET M-5

SEE PART PLAN

TYPICAL LOUNGE

SHEET M-5

1 …" HHWS (MAIN)

3/4" HHWR (FLOOR BRANCH)

3/4" HHWS (FLOOR BRANCH)

RP-II RP-II RP-II RP-II RP-II

1…" HHWR

1…" HHWS

1‰"HRS & HHR-UP

1‰"CONDENSATE

3"HPS

RP-II RP-II RP-II RP-II RP-III

1" HHWS-UP

M1

M1

M5

M1

3/4" HHWS (FLOOR BRANCH)

3/4" HHWR (FLOOR BRANCH)

1 …" HHWS (MAIN)

ARCTIC HOOD

TYPE II

EF-2

ARCTIC HOOD

TYPE II

EF-1

3/4" HHWS (FLOOR BRANCH)

3/4" HHWR (FLOOR BRANCH)

1…" HHWS (MAIN)

RUN PIPING

OVER DOOR AND

ABOVE NEW

CEILING

ARCTIC HOOD

INTAKE TYPE

Description

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-M1

Building # 98

Floor plan

1. Floor - HVAC

20 Jan. 1999

1/8" = 1’-0"LMØ/PKR

98-M1.dwg 5/1/2014 9:40:07 AM

302 305

304A 306A

307A 309A

310A 312A

313A 315A

316A 318A

333A 331A

330A 328A

325A 323A

322A 320A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

DN.

DN.

322 320 318 316 314 312 310 308 306 304 302 300

319 317 315 313 311 309 307 305 303 301

TYPICAL TWO PERSON SUITE

12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"

D.F.

227’-7 1/2"

1’-3 3/4" 1’-3 3/4"

DN.

PLAN, THIRD FLOOR BLDG # 98

FD FD FD

FD

8"x6"

FD FD

12"x8"

FDFD

FD

18"x8"

FD

S

FD

20"x8"

FD FD

FD

FD FD

12"x8"16"x8"

FD FD FD FD

8"x6"

FDFD

FD

FD

MEAG

20"x12"

SAD-DN

10"x6"SAR

200 CFM

ARCTIC HOOD

TYPE II

TYPICAL LOUNGE

SEE PART PLAN

SHEET M-5 SHEET M-5

SEE PART PLAN

TYPICAL BEDROOM 3/4"HHWR(FLOOR BRANCH)

3/4"HHWS(FLOOR BRANCH)3/4"HHWS(FLOOR BRANCH)

3/4"HHWR(FLOOR BRANCH)

RP-II RP-II RP-II RP-II RP-II RP-IV RP-II RP-II RP-II RP-II RP-II

8"x4"SAR

75 CFM EACH

ARCTIC HOOD

TYPE I

1‰"HHS-DN

1‰"HHR-DN

RP-IIRP-IIRP-II RP-II RP-II RP-II RP-II RP-II RP-II RP-IIIRP-IIRP-III

3/4"HHWS(FLOOR BRANCH)

3/4"HHWS(FLOOR BRANCH)

1"HHWR-DN

RV-6

3/4"HHWR(FLOOR BRANCH)

3/4"HHWS(FLOOR BRANCH) 1"HHWS-DN

8"x10"EAD

UP & DN(TYP)

10"x6"EAR

140CFM(TYP)

1‰"HRS

1‰"HRR

16"x28"EAD

UP TO ATTIC

FILTER

HRC-3

P-5

EF-7

F O

R

H E

A T

C O

V E

R Y

S Y S

T

M

P

IP

IN

G

D E

T A

IL

S

S

E

RV-5

1"HHWR-DN1"HHWS-DN

EF-5

ARCTIC HOOD

EF-6

TYPE II

Description

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-M3

Building # 98

Floor plan

3. Floor - HAVC

25 Jan. 1999

98-M3.dwg 5/1/2014 9:40:29 AM

HOT WATER (HG-1)

GENERATOR

(SEE DETAIL

15-M1 AND

GEN. NOTE 1

SHT. M7

INV EL 169.83’

2"VR

4"

CONVERTER (C-1)

(SEE DETAIL

15-M2)

SEE GEN. NOTE 1

SHT. M-7

DUPLEX CONDENSATE

UNIT-PUMPS 9 GAL.

@ 20 PSI, 1/3 HP

(120/1/60) 3500 RPM

RECEIVER 14 GAL.

2"VR

4"

1‰" VENT

TO OUTSIDE

AIR RELEASE

TANK

1…" HHWS

CP-1

PRESSURE

REDUCING STATION

SEE DETAIL THIS SHEET

SAFETY RELIEF

VALVE

4" SIGHT

DRAIN

FULL SIZE

VENT TO FL.

1…" HHWR

HW CIRC. PUMP

SEE NOTE 1

2" 2"

1"

1…"

CW

1…" HHWR

L P

S H H

W R

CO

C

E x D

TANK

H H

W S

1‰"

2"

4"SS

FLASH TANK

THULE AIR BASE

Review:

Approv.:

Design:

Drawn:

Description:

Rev. Date Init.

Sheet: of Date:

Dwg. No.:

Scale:

Description

98-M5

Building # 123

Plan

Plan and Sections

1/8" = 1’-0"

01. Oct. 2000

98-M5.dwg 5/1/2014 9:42:39 AM

102 105

104A 106A

107A 109A

112A 114A

115A 117A

133A 131A

130A 128A

124A 122A

121A 119A

UP

UP

122 120 118 116 114 112 110 108 106 104 102 100

119 117 115 113 111 109 107 105 103 101

TYPICAL TWO PERSON SUITE

D.F.

UP

U P

U P

U P

U P

126 118

PLAN, FIRST FLOOR BLDG # 98

4"

R

R

P-3 P-3

P-1 P-2

P-7

2" VS

" CW-UP4

" HW-UP4

2" WS4"S

2"

3"

2"V CO

4" S DROP THRU FL

1‰" W&V

4" VS

‰" HW-UP

1" CW-UP

4" SS

TYP

FOR 6

FOR 6

TYP

CO

CO

P-2 P-1CO

P-7

CO

R

P-3 P-3

R

4"

INV. EL.173.83’4" S DROP THRU FL

P-3 P-3

4" VS

‰" HW-UP

1" CW-UP

4" SS

2"V P-1 P-2

3" P-7

1‰" W&V

CO

4"S

FOR 3

TYP

R

P-3

2"

P-3

2" VS

" CW-UP4

" HW-UP4

2" WS

R

TYP

FOR 3

P-1 P-2

CO

P-7

CO

R

P-3 P-3

R

P-1

P-2

CO

P-7

CO

R

P-3 P-3

R

P-1

P-2CO

P-7

CO

R

P-3 P-3

R

4"S-SEE SHT. C-1

INV. EL. 173.0’

1‰" FL-UP

FHC

4"S DROP

THRU FL.

INV. EL.173.83’

4" S DROP THRU FL

4" S DROP THRU FL

CO

4"

4"S DROP

THRU FL.

CO

PLAN-SHT. M-5

MECH. RM.-SEE PART

2"VR 4"V.S

4"SS 1‰"VR

2"VS

4"S

1‰"W

2"WS

3"DROP THRU FL.

R

INV. EL.173.83’

INV. EL.173.83’

2‰"FL-UP

3"CW-UP

1"HWR-UP

2"HW-UP

CO

R

2"S

1‰" FL-UP

INV. EL. 173.0’

4"S-SEE SHT. C-1

CO

FHC

R R

P-2 P-7

P-3

CO

P-1

P-3

CO

4"

R R

P-2

P-7

P-3

CO

P-1

P-3

CO

INV. EL.173.83’

R R

P-2

P-7

P-3

CO

P-1

P-3

CO

4" S DROP THRU FL

‰" HW-UP

‰" CW-UP

2" VS

2" WS

R

P-8 ‰" CW-UP

2" WS

2" WS

3" V.S.

2" W&V

2" W&V

3" W.S.

2" W&V

1" HW-UP

1" CW-UP

3" W-2"V

INV. EL.173.83’

CO

P-5

P-6

P-9

P-9

WCO

R

CO

SHT. M-5

SEE PART PLAN

CO

P-4

R

Description

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-M6

Building # 98

Floor plan

1. floor plumbing

21 Jan. 1999

1 198-M6.dwg 5/1/2014 9:43:15 AM

201A 203A

202 205

204A 206A

207A 209A

210A 212A

213A 215A

216A 218A

232A 230A

229A 227A

224A 222A

221A 219A

UP

DN.

UP

DN.

222 220 218 216 214 212 210 208 206 204 202 200

219 217 215 213 211 209 207 205 203 201

TYPICAL TWO PERSON SUITE

D.F.

UP

DN.

PLAN, SECOND FLOOR BLDG # 98

R

P-3

R

4" SS

1 …" CW-DN, 1" CW-UP

" HW-DN, ‰" HW-UP4

4" V.S

TYP

2" V.S.

" CW-DN, ‰" CW-UP4

" HW-DN, ‰" HW-UP4

2" W.S

TYPP-7

P-3

AP

P-1 P-2

1‰"

3/4"

3/4"

3/4"

3/4" 1…"

P-3

R

3/4"

2‰" 2"

3/4"

AP

1‰"

P-1 P-2

P-3

P-7

R

1…"

2" FL-DN, 1‰" FL-UP

FHC

P-3

1‰"

R

3/4"

3/4"

1‰"

AP

1‰"

P-2 P-1

P-3

P-7

R

3/4"

1"

P-3

P-2

1…"

AP P-1

1‰"

P-3

R 3/4"

2"W.S.

3/4"

P-7

R

P-8

R P-3

P-7

R

3/4" P-2

P-3

1‰"

P-1 3/4"

R

2"

AP 1…"

1" 1‰"

R

3/4"

P-7

P-3P-3

P-2

1‰"

AP

P-1

3/4"

1"

R

1"

1‰"

3/4"

P-1

3/4"

R

P-2

1…"

AP P-7

R

P-3 P-3

3/4"

P-1 3/4"

R

P-2

1‰"

AP

P-7

R

P-3 P-3

3/4"

P-1 3/4"

R

P-2

1‰"

AP

P-7

R

P-3 P-3

3/4"

P-1 3/4"

FHC

R

P-2

1‰"

AP

P-7

R

P-3 P-3

2‰" 2"

2" 1"

‰" CW-UP & DN

2"VS

R

2" V.S.

" CW-DN, ‰" CW-UP4

" HW-DN, ‰" HW-UP4

2" W.S

2"

1…"

M-5

M-5

1‰"

2‰"

2‰"

2"

1"

3"

BV

2‰"

1‰"

BV

3/4" P-4

HW-UP"3/42" HW-DN,

1" HWR-DN

CW-UP"3/43" CW-DN,

2‰" FL-DN

P-6

P-9

P-9

P-5

1‰"

1‰" 2‰"

1…" 1…"

R

1…" HW-DN, 1" HW-UP

1…" CW-DN, 1"CW-UP

3" WS

3" VS

2"

2" FL-DN, 1‰" FL-UP3/4"

1‰"

1" 1…"

2" 1…"

2"

3/4"

3/4"1‰" 3/4"

Description

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-M7

Building # 98

Floor plan

2. floor plumbing

21 Jan. 1999

98-M7.dwg 5/1/2014 9:43:38 AM

302 305

304A 306A

307A 309A

310A 312A

313A 315A

316A 318A

333A 331A

330A 328A

325A 323A

322A 320A

DN.

DN.

322 320 318 316 314 312 310 308 306 304 302 300

319 317 315 313 311 309 307 305 303 301

TYPICAL TWO PERSON SUITE

D.F.DN.

PLAN, THIRD FLOOR BLDG # 98

FD FD FD

FD

8"x6"

FD FD

12"x8"

FDFD

FD

18"x8"

FD

S

FD

20"x8"

FD FD

FD

FD FD

12"x8"16"x8"

FD FD FD FD

8"x6"

FDFD

FD

FD

MEAG

20"x12"

SAD-DN

10"x6"SAR

200 CFM

ARCTIC HOOD

TYPE II

TYPICAL LOUNGE

SEE PART PLAN

SHEET M-5 SHEET M-5

SEE PART PLAN

TYPICAL BEDROOM 3/4"HHWR(FLOOR BRANCH)

3/4"HHWS(FLOOR BRANCH)3/4"HHWS(FLOOR BRANCH)

3/4"HHWR(FLOOR BRANCH)

RP-II RP-II RP-II RP-II RP-II RP-IV RP-II RP-II RP-II RP-II RP-II

8"x4"SAR

75 CFM EACH

ARCTIC HOOD

TYPE I

1‰"HHS-DN

1‰"HHR-DN

RP-IIRP-IIRP-II RP-II RP-II RP-II RP-II RP-II RP-II RP-IIIRP-IIRP-III

3/4"HHWS(FLOOR BRANCH)

3/4"HHWS(FLOOR BRANCH)

1"HHWR-DN

RV-6

3/4"HHWR(FLOOR BRANCH)

3/4"HHWS(FLOOR BRANCH) 1"HHWS-DN

8"x10"EAD

UP & DN(TYP)

10"x6"EAR

140CFM(TYP)

1‰"HRS

1‰"HRR

16"x28"EAD

UP TO ATTIC

FILTER

HRC-3

P-5

EF-7

F O

A

C O

V E

R Y

S Y S

T

P

IP

IN

G

D E

T A

IL

S

S

E E

T

M

RV-5

1"HHWR-DN1"HHWS-DN

EF-5

ARCTIC HOOD

EF-6

TYPE II

Description

THULE AIR BASE

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-M8

Building # 98

Floor plan

3. floor - plumbing

25 Jan. 1999

98-M8.dwg 5/1/2014 9:43:59 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-E1.1

Building # 98

Floor plan

1. Floor,, Light

25 Nov. 2002

1/8" = 1’-0"TB

(ALL LIGHT FIXTURES ON THIS LEVEL SUPPLIED

FROM "LP1" UNLESS OTHERWISE NOTED).

TO 2ND FLOOR

‰"C-3 NO. 10 UP

STAIR LTS.

J C1C1

J

Sawk awk

J1

H1

HOAce

S3cd

J2

X2 ce cd

J

L1

X2

S3cd

Y1

S

J2 cd

Sk

Sa a Sb

JJ

SHEET(TYP)

DIAGRAM THIS

SEE WIRING

cb A2 by

J cc

M9

G1

J Scb

Scc c b

Sc

L1 J d cb

C1

A2

G1

L1J

Sca

C1 by

J ca

(TYP)

SEE NOTE 6

Sd

Se e

M1 b

A2 J J

A2 d

M1

M9

M3 J

C1C1 J

Sbw

J

LGT. HEADS

REMOTE EMERGENCY

G1

Sby M9 J bx

J

Sbx

Sf f

Y2

M9 bp

G1

J

Sg g h

L1 2 Sh

J J bv A2 br

Sbt

C1

Sbv bv

A2

G1

J

J

L1

Sj

J j

C1 br bt

Sbr

J

G1

Sm l

Sm

(SEE WIRING DIAGRAM THIS SHEET)

‰"C-2 NO.10 TO BATTERY PACK

A2

IN MECH. ROOM 110

M1 A2

J g

J j

M1 J

C1C1 J

STAIR LGT.

TO 2ND FLOOR

‰"C-3 NO.10 UP

FROM PANELBOARD

STAIR LTG. IS SUPPLIED

CKT. LP1-17

SEE NOTE 5

Y1 bp

Sbp

J

G1

Sn m 3 n

J

J1 p

Sp

L1 3 J r

Sr

J2

Y2

J X2

Sk

G1

J

X3

BATTERY PACKS

FOR REMOTE

EMERG.LT.HEADS

S2 t

G1

J

LP1-11

Y2

J

D1 v n

3A2 J J

A2 r

LT. DISC. SW. (TYP)

D1

S3v

‰"C-3 NO.10 TO EXIT

M3

D1

J w

HOaw v

H1 12

X2

S3n

Saj

Sac

J

LTG. HEADS

REMOTE EMERG.

‰"C-2 NO.10 TO

BATTERY PACK IN

MECH. RM. 110

C14

JJ

Sy

G1 11

J v

LP1

S3v v

J

G1 11

Sx x

Saa

G1

J

J y aa

Y211 G1

Sab ab

L1

D1

D1 v

L1 4

4K1

K1 y

J M5

A2 ab

J

C1C1

JJ

C1

A2

M7

11 G1 ad ac J

Sad ax J

Sax

J

C1

Saw aw

Sae ae

JJ

aw A2 at av Sav

J

G1

JL1

C1 at Sat

Saf af Sag

J ar

M7

G1

J

Sar

Sk ah

L1 ag

Sah

J aj

M5J A2 ad

6 A2 M5 ag

J J aj

6A2

NOTEDJ

ABOVE CEILING

8"x8"WIREWAY

STAIR, SEE NOTE 5(TYP)

2ND FLOOR STAIR LTS.

‰"C-3 NO. 10 UP TO

J

S1 ap

HOAap

J2 an

X2

J1

Sk am S3

J2 an

Y1

S3an

Sam al

Sal

L1 14

(TYP)

‰"C-TYPICAL

UNLESS OTHERWISEM5

CORRIDOR-

SEE NOTE 5

101A 103A

102 105

104A 106A

107A 109A

112A 114A

115A 117A

133A 131A

130A 128A

124A 122A

121A 119A

UP

UP

122 120 118 116 114 112 110 108 106 104 102 100

119 117 115 113 111 109 107 105 103 101

TYPICAL TWO PERSON SUITE

D.F.

UP

U P

U P

U P

U P

126 118

98-E1.1.dwg 5/1/2014 9:36:39 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-E1.2

Building # 98

Floor plan

1. Floor, Power

26 Nov. 2002

30A DISC. SW. IN MECH. ROOM # 110

1…"C-8 NO. 8 PWR & 1 NO. 8 GND TO

CKT-23

UNIT HTR

ELECTRIC

DISC. SW.(TYP)

250V, 30A UNFUSED

EUH-3

PP1A-3

J

10 12

12 GFI

GFI

GFI

CKT-19

1"C-3

NO. 8

CKT-22

J

NO. 8

1"C-5

CKT-21

J

GFI

5 5

CKT-20

1"C-5

NO. 8

J

1…"C-7

NO. 8

J

GFI6

GFI

1 1

GFI

GFI 11

CKT-17

SEE NOTE 6

CKT-18

1…"C-7

NO. 8

J

NO. 8

1"C-5

P2-42

J

SEE SHEET E-7

(RUN EXPOSED UNDER FLOOR)

PP1-14,15

EUH

PP1A-2

GFIGFI

13 34

EUH-1

CKT-16

GFI

"PP1"

FEED FROM PANELBOARD

NEW-HEADBOLT HEATERS

CKT-14

P2-42

CKT-13

J

5#8

EF-2

J

PP1-13

CKT-15

3#8

J

3#8

J

GFI

GFI

ELECTRICAL CLOSET ABOVE

36 23 19

GFI

OTHERWISE NOTED.

NO. 10 UNLESS

ALL WIRING SHOWN ON

THIS SHEET SHALL BE

22 GFI

31 31

GFI 22

PP1A-1

29 29

GFI

GFI

UNLESS OTHERWISE NOTED

THIS SHEET SHALL BE

ALL WIRING SHOWN ON

‰"C-TYPICAL

PLAN SHEET E-7

SEE ENLARGED

MECH. RM.

8"X9" WIREWAY RUN

LENGTH OF CORRIDOR

ABOVE HUNG CEILING

OTHERWISE NOTED

NO. 10 AWG UNLESS

101A 103A

102 105

104A 106A

107A 109A

112A 114A

115A 117A

133A 131A

130A 128A

124A 122A

121A 119A

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19

A

B

C

D

UP

UP

122 120 118 116 114 112 110 108 106 104 102 100

119 117 115 113 111 109 107 105 103 101

TYPICAL TWO PERSON SUITE

D.F.

UP

U P

U P

U P

U P

1’-3 3/4"

12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" - 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6" 12’-6"

1’-3 3/4"

227’-7 1/2"

98-E1.2.dwg 5/1/2014 9:37:07 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-E2.1

Building # 98

Floor plan

2. Floor, Light

BATTERY PACK IN 225

FOR LIGHTING LAYOYT THIS

AREA, SEE PART PLAN

SHEET E-7

‰"C-2 NO.10 TO

ELECTRICAL CLOSET

SEE SHEET E-5

J2

‰"C-3 NO. 10 DN

TO 1ST FLOOR

STAIR LTS.

‰"C-3 NO. 10 UP

TO 3RD FLOOR

STAIR LTS.

ALL LIGHT FIXTURES ON THIS LEVEL SUPPLIED

FROM "LP2" UNLESS OTHERWISE NOTED.

J

J

STAIR LTG. IS SUPPLIED

FROM PANELBOARD

LP1-15, SEE NOTE 5

C1

Y1

J2

Y1

LP1-15

Sa

LP1-15

Sk X1

JM1

a

Sb

2L1 g

M9 J

Sgj

G1

J

Scc c J

L1

JA2

gj gj

C1

J

A2 J bg bh Sbh bg

C1

G1

J

Se

J b b

Sc

2A2 J

2C1 d d

A2 2

M1

Sd

J e

17H1

3/4" CONDUIT CONNECT

EXIST. FIXTURE

‰"C-3 NO. 10

UP TO 3RD FLOOR

STAIR LTS.

STAIR LTG. IS

SUPPLIED FROM

PANELBOARD LP1-17

SEE NOTE 5

J dd Y1

‰"C-3

NO.10 DN.

M3 A2

Sbe

L1 2

Sbg

J bf

M9

G1

J

Sbf be

M9

Y2 G1

J h

‰"C-2 NO. 10 TO

BATTERY PACK IN 225

M1

G J g

A2

Sg C1

J J g

Sh

Sbc

C1

J Sbd bd A2 J bd

L1J

J

G1

J

J A2 bb bc bb

C1

J Sbb

Sl

G1

SjC1 j j

M2 J l

‰"C-2 NO.10 TO EXIT

LT DISC. SW. IN 1ST

FLOOR MECH. ROOM

(TYP)

G1

J2

L1 4 ba

M9

X1

Sba

J

Sm

G1

Sdd

E1

J

J p J

J m C1Sn n

A2 J J

Sp n

4 A2

C1 4 r r

Sr

Y2

BATTERY PACKS FOR

REMOTE EMERG. LTG.

HEADS

J

St

S3

X2

J Y2

LP2-11

G1

J

11 Y2

Sv

M3 J t

M3 v J

Sw

J J

55 W FIXTURE ‰"C-3 NO. 12

UP TO 3RD FLOOR

STAIR LTS.

Sc

J

M1 4

G1

LP2

J x J

J ay

M7

J

G1 11

Say

Sg

C1 4 w w

A2 4

J J

Sx

C1 y

A2 4 y

Sy

M3 J a3

L1

S2a aw

A2

Sax

C1 ax J J

L1J ax

Saw

G1

J av

A2

C1 av

J Sav

11 G1

M5

2a C1 Sab

J J ab ab

A2 6

CORRIDOR-

SEE NOTE 5

‰"C-2 NO.10 TO

BATTERY PACK IN 225

M7 au

M7

Sau ac J

G1

J at A2

C1

Sar ar

J Sat

Sae

Y2

M5 ad

J

C1 ad

A2 6

Sad

J ae

L1

A2ar

J J

Sap

JL1

ap an an

C1

San

J

G1 11

Saf

M7 am J ah

G1

J

Sam

J

A2

M5 af J

Sag C1

J J ag ag

Sah

C1 aj aj

A2

DN TO 1ST FLOOR

J

STAIR LTS.

‰"C-3 NO. 10

ALL WIRING SHOWN ON

THIS SHEET SHALL BE

NO.10 AWG. UNLESS

OTHERWISE NOTE.

STAIR LTG. IS SUP-

PLIED FROM PANELBOARD

LP1-16, SEE NOTE 5.

LP1-16

LP1-16

J2 Y1

Sk

X1

Sal

J2 ayk

Y1

M5

Saj

J al

201A 203A

202 205

204A 206A

207A 209A

210A 212A

213A 215A

216A 218A

232A 230A

229A 227A

224A 222A

221A 219A

UP

DN.

UP

DN.

222 220 218 216 214 212 210 208 206 204 202 200

219 217 215 213 211 209 207 205 203 201

TYPICAL TWO PERSON SUITE

D.F.

UP

DN.

PLAN, SECOND FLOOR BLDG # 98

98-E2.1.dwg 5/1/2014 9:38:01 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-E2.2

Building # 98

Floor plan

2. Floor, Power

SEE PART PLAN

12 GFI

5 GFI

GFI

ALL RECEPTACLES SHOWN ON

NOTE:

SEE NOTE 6

EF-3

SHEET E-7

GFI

6 6

GFI

GFI

GFI

GFI 11

P2-42

GFIGFI

ELECTRICAL

THIS SHEET

PART PLAN

CLOSET SEE

UNLESS OTHERWISE

‰"C-TYPICAL

ELECTRIC RANGE

EF-4

THIS SHEET SHALL BE

ALL WIRING SHOWN ON

OTHERWISE NOTED.

NO. 10 UNLESS

GFI

PANELBOARD "LP2"

P2-42

TO PNL PP2A

1"C-4 NO. 6

DP2A-15

GFI

GFI

PANELBOARD "DP2A"

GFI

GFI 28

OF CORRIDOR ABOVE HUNG CEILING.

8"x8"WIREWAY RUN LENGTH

GFI

PANELBOARD "P2"

22 GFI

GFI

29 GFI

GFI

NOTED.

CONNECTED TO PANELBOARD "P2"

2.nd FLOOR PLAN ARE

UP

DN.

UP

DN.

UP

DN.

98-E2.2.dwg 5/1/2014 9:38:31 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-E3.1

Building # 98

Floor plan

3. Floor, Light

5. KEY OPERATED SWITCHES SHALL BE PROVIDED FOR ALL CORRIDOR AND

LOCATIONS, SEE REFLECTED CEILING PLANS SHOWN ON ARCHITECTURAL

4. LIGHTING FIXTURES ARE SHOWN DIAGRAMMATICALLY ONLY. FOR EXACT

3. FOR ROOM NAME/NUMBER SCHEDULE, SEE ARCHITECTURAL DRAWING

2. FOR PANELBOARD SCHEDULES, SEE SHEET E-12

1. FOR SYMBOLS AND GENERAL NOTES AND FIXTURE SCHEDULE, SEE SHEET E-1

DIAGRAM SHEET E-3

LP3-11, SEE WIRING

DRAWINGS.

STAIR LIGHTING.

C1

LP1-15, SEE NOTE 5

FROM PANELBOARD

STAIR LTG. IS SUPPLIED

‰"C-3 NO. 10 DN

SUPPLIED FROM "LP3" UNLESS

ALL LGT FIXTURES ON THIS LEVEL

OTHERWISE NOTED

M1 bn bn bm

M9 J

Sbj bj

C1

A2 J bj A2 J bg bg

A2

LP1-15

J2 X2

Sbn

M1

Sk

Sa

M1 1 a J

Sb C1

J

G1

Sbm

J

L1 2 c

Sc b b

J

J

C1

A2 d d

Sbh

L1J

G1

J bh

Sd

M1 J

Se e

LGT. HEADS

REMOTE EMERG.

J Sbg M9 bf

M9 J be J

C1

A2

Sbd bd bd

J bb

A2 bb

C1

Sbb

J

A2

J

Sbe

G1

J Sbf

M1

Sf f J

11Y2

J

G1

Sg

A2 g

2C1

L1 Sh h

J g

J

BATTERY PACK IN 326

‰"C-2 NO. 10 TO

bc

J

J

L1

Sbc

G1

Sj j

C1 j

J

M1

11 G1

Sl l

M3

‰"C-3 NO. 10 DN

SEE NOTE 5

PANELBOARD LP1-17

SUPPLIED FROM

STAIR LTG. IS

M9 ba ma

J

E1 13

NOTE:

HEADS

REMOTE EMERG. LTG.

BATTERY PACKS FOR

(TYP)

FLOOR MECH. ROOM

LT DISC. SW. IN 1ST

‰"C-2 NO.10 TO EXIT

J2

G1

X2

Sba

J

Sma

G1

Sn

Sm m J

C1 n

4A2 n

J

C1 p

L1 Sp

J

J J A2 r r

Sr

Y2

S3

J

X2

Y2

J

St

M3 J t

J

G1 11 u

M3

Su

J Sw

Sam

Sac

BATTERY PACK IN 225

ay

M7 J

A2 axSax

A2 J ax

J

Sav av av

J

G1

J

J

LP3

M1

A2 w

4C1 w

Sx x J

A2 J y

C1

G1

J Say

Sy y

Sy y

M3 J

SEE SHEET E-6

ELECTRICAL CLOSET

Saa

J

L1J

J

Saw aw

G1

M5 aa

Y2

J

G1

C1 Sab

L1

A2 ab ab

J

‰"C-2 NO.10 TO

as

M7 M7 au at J

Sas as

A2 J J A2 ap ap

Sap M7

J an

M5

Sau

11 G1 ad

J ac

J A2 ad

C1 6 Sad

J

Sat

J

Sae ae

A2

J

Sar

L1J ar

G1 11

Saf

M5 af J

Sag C1

J

G1

San

M1 Sah ah ag ag

JJ

J aj

C1

A2 aj

LP1-16 SEE NOTE 5.

FROM PANELBOARD

STAIR LTG. IS SUPPLIED

‰"C-3 NO. 10

DN TO 1ST FLOOR

M1 am am

STAIR LTG.

OTHERWISE NOTED

‰"C-TYPICAL UNLESS

ABOVE CEILING

8"x8" WIREWAY

LP1-16

M1 12

X2 Sk

J2

Sal

Saj

M5 J al

UNLESS OTHERWISE NOTED

SHEET SHALL BE NO. 10 AWG.

ALL WIRING SHOWN ON THIS

301A 303A

302 305

304A 306A

307A 309A

310A 312A

313A 315A

316A 318A

333A 331A

330A 328A

325A 323A

322A 320A

DN.

DN.

322 320 318 316 314 312 310 308 306 304 302 300

319 317 315 313 311 309 307 305 303 301

TYPICAL TWO PERSON SUITE

D.F.DN.

PLAN, THIRD FLOOR BLDG # 98

98-E3.1.dwg 5/1/2014 9:39:01 AM

Review:

Drawn:

Design:

Description:

DateRev. Init.

Approv.: Scale:

Date:

Dwg. No.:

Sheet: of

98-E3.2

Building # 98

Floor plan

3. Floor, Power

PANELBOARD "P3"

PANELBOARD "DP3A"

PANELBOARD "LP3"

ELECTRIC RANGE

GFI

GFI

GFI

GFI 3

1 3

P3-42

6 GFI

GFI

EF-5

GFI

GFI

11 11

GFI

DP2A-15

P3-42

1"IMC 4 NO.6

TO PNL DP3A

GFI

GFI GFI

EF-6

GFI

GFI

8"x8"WIREWAY RUN LENGTH

OF CORRIDOR ABOVE HUNG CEILING.

25 25

GFI GFI

GFI22

GFI

20 18

29 29

GFIGFI

NOTED.

OTHERWISE NOTED

UNLESS OTHERWISE

‰"C-TYPICAL

NO. 10 AWG UNLESS

THIS SHEET SHALL BE

ALL WIRING SHOWN ON

PROTECTION 208Y,

MOTOR CIRCUIT

DISCONNECT SWITCH WITH

COMBINATION MAGNETIC

PUMP P5 DP3A-10

HOT WATER CIRCULATING

DP3A-II

EXHAUST FAN EF-7

208y, 3 POLE

NEMA SIZE 1

MOTER STARTER AND

301A 303A

302 305

304A 306A

307A 309A

310A 312A

313A 315A

316A 318A

333A 331A

330A 328A

325A 323A

322A 320A

DN.

DN.

322 320 318 316 314 312 310 308 306 304 302 300

319 317 315 313 311 309 307 305 303 301

D.F.DN.

98-E3.2.dwg 5/1/2014 9:39:40 AM

THIS PAGE INTENTIONALLY LEFT BLANK