Design and Construction Supervised by

Renovate Community Center

US Army Corps of Engineers New York

Building 484 Lakehurst, NJ

PROJECT IDENTIFICATION SIGN

MILITARY PROJECT

The graphic format for this 4' x 6' sign panel follows the legend guidelines and layout as specified below. The large 4' x 4' section of the panel in the right is to be white with black legend. The 2' x 4' section of the sign on the left with the full corps Signature (reverse version) is to be screen printed Communication Red on the white background.

See attached sheet for fabrication and mounting guidelines.

Legend Group 1: One- to two-line description of Corps relationship to project Color: White Typeface: 1.25" Helvetica Regular Maximum line length: 19"

Legend Group 2: Division or District Name (optional). Place below 10.5" Reverse Signature (6" Castle) Color: White

Legend Group 3: One- to three-line project title legend describes the work being done under this contract.

Color: Black Typeface: 3" Helvetica Bold Maximum line length: 42"

Legend Group 4: One-to two-line identification of project or facility (civil works) or name of sponsoring department (military).

Color: Black Typeface: 1.5" Helvetica Regular

4.5

2"

6.25"

10.5"

2.5

SAMPLE

(Dimensions are in inches)

6"

4.5"

2.25"

9.5"

1.875"

7.75"

Cross-align the first of Legend Group 4 with the first line of the Corps Signature (US Army Corps) as shown.

Legend Group 5a-b: One-to-five line identification of prime contractors including: type (architect, general contractor, etc.), corporate or firm name, city, state.

Use of Legend Group 5 is optional.

Color: Black

Maximum line length: 21"

All typography is flush left and rag right upper and lower case with initial capitals only as shown.

Letter and word spacing to follow Corps standards as specified in

* Appendix D

* Refers to the U.S. Army Corps of Engineers, "Sign Standards Manual", EPS-310-1-6.

PROJECT IDENTIFICATION SIGN

Sign Legend Panel Post Specification Mounting Color Type Size Size Code Height Bkg/Lgd CID-01 various 4' x 6' 4' x 4' HDO-3 48" WH-RD/BK

Safety is a Job Requirement

Renovate Community Center, B484 Lakehurst, NJ

This project has operated:

Days without & lost time injury

Total days worked on this contract

Lost time injuries

SAFETY PERFORMANCE SIGN

The graphic format, color, size and type-faces used on the sign are to be reproduced exactly as specified below. The title with First Aid logo in the top section of the sign, and the performance record captions are standard for all signs of this type. Legend Group 2 and 3 below identify the project and the contractor and are to be placed on the sign as shown.

Safety record numbers are mounted on individual metal plates and are screw-mounted to the background to allow for daily revisions to posted safety performance record.

Legend Group1: Standard two-line title "safety is a Job Requirement", with (8" od.) Safety Green First Aid logo. Color: To match PMS 347 Typeface: 3" Helvetica Bold Color: Black

Legend Group 2: One- to two-line project title legend describes the work being done under this contract and name of host project.

10.5"

Color: Black 2.25" Typeface: 1.5" Helvetica Regular

Legend Group 3: One - to two-line identification: name of prime

2.25" 4" contractor and city, state address. 1.875" 4.875" Color: Black 3" Typeface: 1.5" Helvetica Regular Maximum line length: 42" 1.875" 4.875"

Legend Group 4: Standard safety 3" record captions as shown. 1.875"

4.875"

Replaceable numbers are to be mounted on white .060: aluminum plates and screw-mounted to background.

3.875" 3"

Dimensions inches.

Typeface: 3" Helvetica Regular Plate size: 2.5"x.5"

All typography is flush left and rag right, upper and lower case with initial capitals only as shown.

Letter- and word-spacing to follow Corps standards as specified in Appendix D. *

See attached sheet for fabrication and mounting guidelines.

* Refer to the U.S. Army Corps of Engineers, "Sign Standards Manual", EPS-310-1-6.

Sign Legend Panel Post Specifications Mounting Color Type Size Size Size Code Height Bkg/Lgd CID-02 various 4"x4" 4"x4" HDO-3 48" WH/BK-GR

.875"

3.125"

.975"

SAFETY PERFORMANCE SIGN

3" 8"

5 6 2

Fabrication and Mounting Guidelines

As Construction Project Identification signs Detailed specifications for and Safety Performance signs are to be HDD plywood panel preparation are pro fabricated and installed as described vided in Appendix B.** below. The signs are to be erected at a Shown below the mounting diagram is location designated by the contracting of a panel layout grid with spaces provided ficer and shall conform to the size, format, for project information. Photocopy this and typographic standards shown o page and use as a worksheet when pre the attached sheets. paring sign legend orders.

The sign panels are to be fabri-cated from .75" High Density Over-lay Plywood. Panel preparation t follow HDD specifications provided in Appendix B. **

Sign graphics to be prepared on a white non-reflective vinyl film wit positionable adhesive backing

All graphics except for the Com-munications Red background with Corps signature on the project sign are to be die-cut or computer-cut non-reflective vinyl, pre-spaced legends prepared in the sizes and typefaces specified and applied to the background panel followin the graphic formats shown on the attached sheets.

The 2'x4' Communications Red panel (to match PMS-032) with full Corps signature (reverse ver-sion) is to be screen printed on the white background. Identifica tion of the District or Division may be applied under the signature with white cut vinyl letters pre

(Dimensions in inches)

** Refers to the U.S. Army Corps of Engineers, "Sign Standards Manual", EP-310-1-6.

48"

48" pared to Corps standards. Large Construction Project Sign scale reproduction artwork for the Legend Group 1: Corps Relationship signature is provided on page 4.8 (photographically enlarge from 1. 6.875" to 10.5"). **

2.

Drill and Insert six (6) .375" T-nuts from the front face of the HDD Legend Group 2: Division/District Name sign panel. Position holes as 1. shown. Flange of T-nut to be flush with sign face. 2.

Apply graphic panel to prepared Legend Group 3: Project Title HDD plywood panel followin manufacturers' instructions. 1.

Sign uprights to be structura 2.

grade 4"x4" treated Douglas Fir or Southern Yellow Pine. No.1 o 3.

better. Post to be 12" long. Drill six (6) .375" mounting holes in Legend Group 4: Facility Name uprights to align with T-nuts in sign panel. Countersink (.5") back of 1.

hole to accept socket head cap screw (4"x.375"). 2.

Assemble sign panel and uprights Legend Group 5a: Contractor/A&E Legend Group 5b: Contractor /A&E Imbed assembled sign panel and uprights in 4" hole. Local soil con 1. 1. ditions and/or wind loading ma require bolting additional 2"x4 2. 2. struts on inside face of uprights to reinforce installation as shown 3. 3.

4. 4.

5. 5.

Safety Performance Sign Legend Group 1: Project Title

1.

2.

Legend Group 2:

Contractor/A&E 1.

2.

The graphic format for this 4' x 6' sign panel follows the legend guidelines and layout as specified below. The large 4' x 4' section of the panel in the right is to be white with black legend. The 2' x 4' section of the sign on the left with the ful...
The graphic format, color, size and type-faces used on the sign are to be reproduced exactly as specified below. The title with First Aid logo in the top section of the sign, and the performance record captions are standard for all signs of this type....