GROUND FLOOR

0' - 0"

B.O. SOFFIT

32' - 0"

A-301

N-1N-2N-3

T.O. CAST STONE

9' - 0"

BRICK VENEER TO MATCH AND

ALIGN WITH EXIST. ADJACENT.

RUNNING BOND

CAST STONE SILL TO MATCH

PROFILE, FINISH AND ALIGH

WITH EXIST. ADJACENT

NEW CONTINUOUS INSULATED

METAL PANEL TO MATCH FINISH

OF EXIST. ADJACENT

NEW TRANSLUSCENT WALL

PANEL CLERESTORY UNIT TO

AND MATCH UNIT SIZE AND

ALIGN WITH EXIST. ADJACENT

NEW GUTTER AND

DOWNSPOUT, TYP. MATCH

FINISH, PROFILE AND ALIGN

WITH THAT OF EXIST.

ADJACENT

SOFFIT AND FASCIA TO

MATCH FINISH, PROFILE

AND ALIGN WITH THAT OF

EXIST. ADJACENT

EXISTING ADJACENT C-17

HIGH BAY TRAINING SPACE

BEYOND

STANDING SEAM METAL

ROOFING TO MATCH THAT

OF AND ALIGN WITH EXIST.

ADJACENT NEW ROOF PANELS &

SUBSTRATE BEYOND

ALIGN

ALIGN

INFILL PORTION OF EXIST.

CLERESTORY WITH INSULATED

METAL PANEL TO MATCH FINISH

OF EXIST. ADJACENT

N-4

20' - 0" 20' - 0" 20' - 0"E.J. TYP.

GUTTER E.J.

NEW GUTTER. MATCH FINISH,

PROFILE AND ALIGN WITH

THAT OF EXIST. ADJACENT

EXISTING DOWNSPOUTS TO

REMAIN OR BE REUSED AND

CONNECTED TO SECTION OF

NEW GUTTER

N-2.5

GROUND FLOOR

0' - 0"

B.O. SOFFIT

32' - 0"

N-AN-CN-D

A-301

T.O. CAST STONE

9' - 0"

CAST STONE SILL TO MATCH

PROFILE, FINISH AND ALIGH

WITH EXIST. ADJACENT

NEW CONTINUOUS INSULATED

METAL PANEL TO MATCH

FINISH OF EXIST. ADJACENT

NEW TRANSLUSCENT WALL

PANEL CLERESTORY UNIT TO

AND MATCH UNIT SIZE AND

ALIGN WITH EXIST. ADJACENT

NEW GUTTER AND

DOWNSPOUT. MATCH FINISH,

PROFILE AND ALIGN WITH

THAT OF EXIST. ADJACENT

SOFFIT AND FASCIA TO

MATCH FINISH, PROFILE

AND ALIGN WITH THAT OF

EXIST. ADJACENT

STANDING SEAM METAL

ROOFING TO MATCH THAT

OF AND ALIGN WITH EXIST.

ADJACENT

INSULATED SECTIONAL OVERHEAD DOOR

TO MATCH FINISH, SIZE AND ALIGN WITH

THAT OF EXIST. ADJACENT

BRICK VENEER TO MATCH AND

ALIGN WITH EXIST. ADJACENT.

RUNNING BOND

EQ. EQ. EQ. EQ. 4' - 11"

EXISTING ADJACENT C-17 HIGH

BAY TRAINING SPACE

LINE OF EXISTING ROOF

SLOPE

ALIGN

ALIGN

CONT. NEW ROOF PANELS OVER

EXIST. ROOF SUBSTRATE

STL. ANGLE CORNER GUARD UP TO

UNDERSIDE OF SILL. SIZE & FINISH TO

MATCH EXIST. ADJACENT, TYP.

N-B

A-301

E.J.EXISTING DOWNSPOUT TO

REMAIN OR BE REUSED

EXISTING GUTTER TO REMAIN OR

BE REUSED AND CONNECTED TO

SECTION OF NEW GUTTER

GUTTER E.J.

EXIST. EXT. SIGN

ADJACENT EXIST.

DOOR TO BE

MATCHED FOR NEW

SIGNS WHERE

NOTED

GROUND FLOOR

0' - 0"

B.O. SOFFIT

32' - 0"

N-A N-C N-D

A-301

T.O. CAST STONE

9' - 0"

BRICK VENEER TO MATCH

AND ALIGN WITH EXIST.

ADJACENT. RUNNING BOND

CAST STONE SILL TO MATCH

PROFILE, FINISH AND ALIGH

WITH EXIST. ADJACENT

NEW CONTINUOUS

INSULATED METAL PANEL TO

MATCH FINISH OF EXIST.

ADJACENT

NEW TRANSLUSCENT WALL

PANEL CLERESTORY UNIT TO

AND MATCH UNIT SIZE AND

ALIGN WITH EXIST. ADJACENT

NEW GUTTER AND

DOWNSPOUT. MATCH FINISH,

PROFILE AND ALIGN WITH

THAT OF EXIST. ADJACENT

SOFFIT AND FASCIA TO

MATCH FINISH, PROFILE

AND ALIGN WITH THAT OF

EXIST. ADJACENT

STANDING SEAM METAL

ROOFING (BEYOND) TO

MATCH THAT OF AND ALIGN

WITH EXIST. ADJACENT

EQ. EQ.EQ.EQ.4' - 11"

INSULATED SECTIONAL OVERHEAD DOOR

TO MATCH FINISH, SIZE AND ALIGN WITH

THAT OF EXIST. ADJACENT

EXISTING ADJACENT C-17

HIGH BAY TRAINING SPACE

ALIGN

ALIGN

STL. ANGLE CORNER GUARD

UP TO UNDERSIDE OF SILL.

SIZE & FINISH TO MATCH

EXIST. ADJACENT, TYP.

N-B

A-301

GUTTER E.J.

E.J.

EXISTING GUTTER TO REMAIN

WITH CONT. DRAINAGE TO NEW

GUTTER

NEW EXT. SIGN TO MATCH EXIST., BUT READ AS: "AET 2, TRAINING,

ROOM". SEE ELEVATION 2 OF SHEET A-201

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D E

SI

G

N B

Y:

SB

M

T B

Y:

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

A

TI

O N

N O

U S

A R

M Y

C O

RP

S

O F

EN

G

IN

EE

R S

C K

D B

Y

US Army Corps of Engineers ®

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SHEET OF

/8

'-0

5/

/ 2

:4 6 :

A

M

A D

D

IT

IO

N

T O

M A

IN

TE

N A

N C

E

TR

A

IN

IN

G

FA

C

IL

IT

Y

JU

N

E

, 2

New York District

D es ig ne r

Au th or

Ap pr ov er

A-201

N

EW

Y O

R K

D

IS

TR

IC

T

C he ck er

BU

IL

D

IN

G E

LE

VA

T I O

N S

JB

M cG U

IR

E

D

IX

L

AK

E H U

R

ST

A- 2 0

1-

1/8" = 1'-0"1 NORTH ELEVATION

1/8" = 1'-0"2 EAST ELEVATION

1/8" = 1'-0"3 WEST ELEVATION

GENERAL ARCHITECTURAL NOTES

1.NEW EXTERIOR MATERIALS TO MATCH EXISTING ARE TO MATCH EXPOASED FINISH

AND COLOR. SIZE, TYPE AND THICKNESS MAY VARY. CCONTRACTOR TO FIELD VERIFY

AND COR TO APPROVE.

2.OVERHEAD DOORS TO BE INSULATED SECTIONAL TYPE WITH CONTINUOUS

WEATHERSEAL AND OR WEATHER STRIPPING AT JAMBS, HEAD AND SILL. SEE DETAILS

4, 5 & 6 OF DRAWING SHEET A-502.

3.SWING DOORS TO BE HOLLOW METAL TYPE WITH CONTINUOUS WEATHERSTRIPPING.

SEE DETAILS 2 & 3 OF DRAWING SHEET A-502.

4.COLOR RANGE AND TEXTURE OF BRICK SHALL MATCH THAT OF EXISTING ADJACENT

BUILDING. IT IS ASSUMED THAT THIS IS BOREN PAMLICO NO. 11-55-1, AS

MANUFACTURERED BY PLEASANT GARDEN PLANT #6 TO MATCH THAT OF EXISTING

ADJACENT BUILDING, OR EQUIVALENT AS APPROVED CONTRACTING OFFICER. COLOR

AND COLOR RANGE INDICATED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE

NOT INTENDED TO LIMIT SESLECTION OF SIMILAR COLOR OR COLOR RANGE FROM

OTHER MAUFACTURER. CONTRACTOR TO FIELD VERIFY COLOR RANGE AND TEXTURE

WITH COR APPROVAL.

5.PAINT COLOR OF INTERIOR OF NEW ADDITION TO M ATCH THAT OF ADJACENT

EXISTING ROOM. EXPOSED ELEMENTS, SUCH AS STRUCTURAL BRACING, UNDERSIDE

OF ROOF DECKING, DUCTS AND CONDUITS, ETC.ARE TO BE PAINTED THE SAME COLOR.

6.NEW FIRE EXTINGUISHER IS GOVERNMENT FURNISHED AND GOVERNMENT INSTALLED

BUT THE EXTINGUISHER BRACKET IS CONTRACTOR FURNISHED AND CONTRACTOR

INSTALLED.

7.ALL ANNOTATED EXPANSION JOINTS TO BE 1/2 INCH WIDE.

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

A

M

EN

D M

EN

T

2:

IN

T.

E

XT

. S

IG

N

AG

E

/1 8/

B.O. SOFFIT

32' - 0"

N-AN-CN-D

A-301

A-501

T.O. CAST STONE

9' - 0"

EXIST.

SUPENDED

ACOUTICAL TILE

CEILIING SYSTEM

AFFECTED BY

CONSTRUCTION

OF NEW ROOF

ABOVE TO BE

REPLACED WITH

MATCHING

CEILING KC-10 ENGINE TRAINING

TRAINING DEVICE WITH

PYLON

N-B

A-301

AL

IG

N

NEW 1 HOUR FIRE RATED SEPERATION

WALL FROM TOP OF EXIST. WALL TO

UNDERSIDE OF ROOF DECKING: 3 5/8"

METAL STUDS @ 16" O.C. WITH 5/8" THK.

TYPE 'X' GYP. BD.

GROUND FLOOR

0' - 0"

B.O. SOFFIT

32' - 0"

A-301

N-1N-2N-3

A-501

T.O. CAST STONE

9' - 0"

EXISTING ADJACENT C-17 HIGH

BAY TRAINING SPACE BEYOND

NEW ROOF PANELS &

SUBSTRATE BEYOND

INFILL PORTION OF EXIST.

CLERESTORY WITH INSULATED

METAL PANEL TO MATCH FINISH

OF EXIST. ADJACENT

INFILL PORTION OF EXIST.

CLERESTORY WITH INSULATED

METAL PANEL TO MATCH FINISH

OF EXIST. ADJACENT

N-4 N-2.5

NEW INT. SIGN TO MATCH EXIST. EXT. SIGN, BUT READ

AS: "AET, TRAINING, ROOM". SEE ELEVATION 2 OF SHEET

A-201

GROUND FLOOR

0' - 0"

B.O. SOFFIT

32' - 0"

A-301

N-1N-2N-3

T.O. CAST STONE

9' - 0"

N-4

EXISTING ADJACENT C-17 HIGH

BAY TRAINING SPACE BEYOND

NEW ROOF PANELS &

SUBSTRATE BEYOND

INFILL PORTION OF EXIST.

CLERESTORY WITH INSULATED

METAL PANEL TO MATCH FINISH

OF EXIST. ADJACENT

INFILL PORTION OF EXIST.

CLERESTORY WITH INSULATED

METAL PANEL TO MATCH FINISH

OF EXIST. ADJACENT

KC-10 ENGINE TRAINING

TRAINING DEVICE WITH

PYLON

KC-10 MAIN LANDING

GEAR TRAINING

DEVICE

A-502

N-2.5

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D E

SI

G

N B

Y:

SB

M

T

BY

SI

ZE

FI

LE

N

AM

E:

IS

SU

E D

AT

E:

C O

N

TR

AC

T

N O

SO

LI

C

IT

A

TI

O N

N O

U S

A R

M Y

C O

RP

S

O F

EN

G

IN

EE

R S

C K

D B

Y

US Army Corps of Engineers ®

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

PL

O

T

SC

AL

E:

PL

O

T D

AT

E:

SHEET OF

/8

'-0

5/

/ 2

:4 7 :

A

M

A D

D

IT

IO

N

T O

M A

IN

TE

N A

N C

E

TR

A

IN

IN

G

FA

C

IL

IT

Y

JU

N

E

, 2

New York District

D es ig ne r

Au th or

Ap pr ov er

A-301

N

EW

Y O

R K

D

IS

TR

IC

T

C he ck er

BU

IL

D

IN

G S

E C

TI

O N

S

JB

M cG U

IR

E

D

IX

L

AK

E H U

R

ST

A- 3 0

1-

1/8" = 1'-0"1 SECTION A

1/8" = 1'-0"3 SECTION C

1/8" = 1'-0"2 SECTION B

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

A

M

EN

D M

EN

T

2:

IN

T.

E

XT

. S

IG

N

AG

E

/1 8/

N-1 N-2 N-3 N-4N-2.5N-1 N-2 N-3

Level 1 0' - 0"

Level 2 32' - 0"

Level 3 36' - 6"

GROUND FLOOR

0' - 0"

N-1 N-2 N-3 N-4N-2.5

3'

5/

SHEET

IDENTIFICATION

1 2 3 4 5

D R

AW

N

B Y:

D

ES

I G N

B Y:

SB

M

T

BY

S

IZ

E :

FI

LE

N

A M

E:

IS

SU

E D

A

TE

C O

N

TR

AC

T

N O

S O

LI

C

IT

AT

IO

N

N O

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

C

KD

B Y:

US Army Corps of Engineers ®

" x

4"

D

C

B

A

FI

LE

N U

M

BE

R

P

LO

T

SC

A

LE

P

LO

T D

AT

E:

SHEET OF

/4

'-0

5/

/ 2

:0 0 :

A

M

A D

DI

T I

O N

T O M

A

IN

TE

N

A N

CE

T

R

AI

NI

NG

FA

C

IL

IT

Y

/1

2/

Enter District

D es ig ne r

A ut ho r

A pp ro ve r

M-103

N

EW

Y O

R K

D

IS

TR

IC

T

C he ck er

BU

IL

D

IN

G S

E C

TI

O N

JB

M cG U

IR

E

D

IX

L

AK

E H U

R

ST

M -1

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

1/4" = 1'-0"1 Section 1

2 3D- VIEW

Sheets
A-201 - BUILDING ELEVATIONS
A-301 - BUILDING SECTIONS
M-103.pdf
Sheets
M-103 - BUILDING SECTION

File details come from the government source that posted it. Updated .