1ST FLOOR
100' - 0"
ADDITION LOWER LEVEL
83' - 0"
ART
A.1
B.1
INFORMATION CENTER
B16
A-531 5A 3' - 4 3/16"
CAST STONE PARAPET CAP
MODIFIED BITUMEN ROOFING
OVER 1/2" RECOVERY BOARD
OVER 4" POLYISO INSULATION
OVER VAPOR RETARDER
OVER METAL ROOF DECK
STRUCTURAL STEEL
MEMBER, REFER TO
STRUCTURAL
DRAWINGS
SUSPENDED ACOUSTICAL
CEILING
PRE-FIN. BLAST
RESISTANT ALUM. &
GLASS WINDOW
SYSTEM
ELEVATED CONCRETE
SLAB OVER METAL DECK,
REFER TO STRUCTURAL
DRAWINGS
2-1/2" RIGID INSULATION OVER
BINTUMINOUS DAMP PROOFING
2 -1/4" AIR SPACE
FACE BRICK VENEER
6" METAL STUD JOISTS WITH R-19 BATT
INSULATION AND VAPOR RETARDER
METAL DECK, REFER TO
STRUCTURAL DRAWINGS
STANDING SEAM METAL ROOF OVER SELF
ADHERING UNDERLAYMENT OVER 5/8"
GLASS-MAT GYPSUM ROOF SHEATHING
6" METAL GUTTER
SUSPENDED
ACOUSTICAL CEILING
8" CMU WITH HORIZONTAL GALV.
METAL VENEER TIES @ 16" o.c. MAX.
REFER TO STRUCTURAL DRAWINGS
FOR ADDITIONAL REINFORCEMENT &
GROUT REQUIRMENTS
STRUCTURAL STEEL
MEMBER, REFER TO
STRUCTURAL
DRAWINGS
PRE-FIN. BLAST
RESISTANT ALUM. &
GLASS WINDOW
SYSTEM
2" RIGID FOUNDATION
INSULATION, EXTEND MIN. 2'-0"
UNDER SLAB
CONCRETE SLAB, REFER
TO STRUCTURAL
DRAWINGS
8" 7'
4"
1'
4"
FILL VOID BETWEEN FLANGES
WITH CMU (SOAPS)
A-530 3A
A-620 4A
A-530 5A
A-620 4D
A-620 4D
1' - 4"
1' - 4"
APPROX. LOCATION OF
FINISH GRADE, REFER
TO CIVIL DRAWINGS
CAST STONE BAND
CAST STONE BAND
FACE BRICK VENEER
2-1/4" AIR SPACE
2-1/2" RIGID INSULATION
OVER BITUMINUOUS
DAMP PROOFING
8" CMU WITH HORIZONTAL GALV.
METAL VENEER TIES @ 16" o.c. MAX.
REFER TO STRUCTURAL DRAWINGS
FOR ADDITIONAL REINFORCEMENT &
GROUT REQUIRMENTS
CAST STONE BAND
5/8" GYP. BOARD
1ST FLOOR
100' - 0"
ADDITION LOWER LEVEL
83' - 0"
J
1'
4" 7'
4"
1'
4" 3'
4"
8"
8"
CAST STONE PARAPET CAP
MODIFIED BITUMEN
ROOFING OVER 1/2"
RECOVERY BOARD
OVER 4" POLYISO
INSULATION OVER
VAPOR RETARDER
OVER METAL ROOF
DECK
STRUCTURAL STEEL
MEMBER, REFER TO
STRUCTURAL
DRAWINGS
SUSPENDED ACOUSTICAL
CEILING
MASONRY PILASTER, BEYOND
8" CMU WITH HORIZONTAL
GALV. METAL VENEER TIES @
16" o.c. MAX. REFER TO
STRUCTURAL DRAWINGS FOR
ADDITIONAL REINFORCEMENT
& GROUT REQUIREMENTS
2-1/2" RIGID INSULATION
OVER BITUMINUOUS DAMP
PROOFING
CAST STONE ACCENT BAND
CAST STONE ACCENT BAND
ELEVATED CONCRETE
SLAB OVER METAL DECK,
REFER TO STRUCTURAL
DRAWINGS
STRUCTURAL STEEL
MEMBER, REFER TO
STRUCTURAL
DRAWINGS
CONCRETE SLAB, REFER
TO STRUCTURAL
DRAWINGS
SUSPENDED ACOUSTICAL
CEILING
GALV. STEEL CANOPY CONNECTION ROD
AND ATTACHMENTS, REFER TO
STRUCTURAL DRAWINGS
EXTERIOR MTL. CANOPY
REFER TO DETAIL
HOLLOW METAL DOOR, PAINT
1/2" SEALANT WITH COMPRESSIBLE
FILLER
CONCRETE DOCK SLAB AND
WALLS, SLOPE SLAB AWAY FROM
BUILDING, REFER TO STRUCTUAL
DRAWINGS
A-603 4D
A-530 3A
A-530 5B
SLOPE
4' - 4"
TOP OF DOCK SLAB 1/2" BELOW
FINISHED FLOOR AT ALL EXTERIOR
DOORS, TYP. REFER TO STRUCTURAL
DRAWINGS
1' - 4"
A-531 5B
2" RIGID FOUNDATION
INSULATION, EXTEND MIN.
2'-0" UNDER SLAB
DOCK BUMPERS, BEYOND
1' - 10"
2' - 2"
J.2
D
2 3
C
A
B
SHEET
A N
SI
D
U . S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y
C K
D B
Y
D E
S
IG
N
ED
B Y
D
AT
E:
SI
ZE
S U
B M
IT
TE
D B
Y
PL
O
TT
ED
B Y:
PL
O
T D
AT
E:
D
ES
C R
IP
TI
O N
D
AT
E
C O
N
TR
A C
T N
O
M
AR
K A
P P
R
US Army Corps of Engineers New York District
D
ES
C R
IP
TI
O N
D
AT
E M
AR
K
A P
P R
SHEET
REFERENCE
NUMBER
OF
M
AY
N
YD
A
/E C
O
VE
R S
U
BM
IT
TE
D B
Y:
P
LO
T
D
AT
E:
W
6-
-D
-0
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
WO
OL
PE
RT
3 F ou nta ins P ark wa y Su ite
Fa irv iew
H eig hts
, IL
8-2
Te l: (
8)
2-7
Fa x:
(61
8)
2-0 ww w.
wo olp ert
.co m
9/
/2
:5 3:
A
M
9/
/2
:5 3:
A
M C
R ev it
Lo ca l\W es t P oi nt M
S_ D
EV
.rv t
W
AL
L S
EC
TI
ON
S
A-311
C A
S, G
R C
, C E
D
C
AS
W R
T
A -3
.d w g
J
U
LY
M
JL
M
JL
100% CONSTRUCTION
DOCUMENTS
W E
S T
P O
IN
T
M
ID
D L
E S
C H
O O
L A
D D
IT
IO
N A
N D
R E
N O
V A
T
IO
N W
E S
T P
O
IN
T, N
E W
Y O
R K
SCALE: 3/4" = 1'-0" A-101B
4AWALL SECTION
0' 1' 2'6" 0' 1' 2'6"SCALE: 3/4" = 1'-0" A-101B
1AWALL SECTION
A
M
EN
D M
E N
T
A U
G
M
JL
A M
EN
D
M E
N T
S
E P
M
JL
http://www.nan.usace.army.mil/ http://www.woolpert.com/
BASEMENT
87' - 0"
1ST FLOOR
100' - 0"
ADDITION LOWER LEVEL
83' - 0"
STANDING SEAM METAL ROOF OVER
SELF ADHERING UNDERLAYMENT
OVER 5/8" GLASS MAT GYPSUM ROOF
SHEATHING OVER METAL DECK
LINE OF PILASTER BEYOND
LINE OF ROOF, BEYOND
TRANSLUCENT WALL PANEL FACADE
MODIFIED BITUMEN ROOFING OVER
1/2" RECOVERY BOARD OVER 4"
POLYISO INSULATION OVER METAL
DECK
STRUCTURAL MEMEBER,
REFER TO STRUCTURAL
DRAWINGS
FACE BRICK VENEER
2-1/4" AIR SPACE
2-1/2" RIGID INSULATION
OVER BITUMINOUS DAMP
PROOFING
CAST STONE ACCENT
BAND
LINE OF COLUMN WRAP, BEYOND
STRUCTURAL MEMBERS, REFER TO
STRUCTURAL DRAWINGS
8" CMU WITH
HORIZONTAL GALV.
METAL VENEER TIES @
16" o.c. MAX. REFER TO
STRUCTURAL DRAWINGS
FOR ADDITIONAL
REINFORCEMENT &
GROUT REQUIREMENTS
SUSPENDED ACOUSTICAL CEILING
PRE-FINISHED BLAST
RESISTANT INSULATED
ALUMINUM AND GLASS
WINDOW / DOOR SYSTEM
STRUCTURAL MEMBERS, REFER TO
STRUCTURAL DRAWINGS
LINE OF CONCRETE PIER,
BEYOND, REFER TO STRUCTURAL
DRAWINGS
ELEVATED CONCRETE SLAB OVER
METAL DECK, REFER TO
STRUCTURAL DRAWINGS
CONCRETE FONDATION
WALL, REFER TO
STRUCTUAL DRAWINGS
CORRIDOR RAMP METAL
HANDRAIL
CORRIDOR
C105
CORRIDOR
A-533 3A
A-533 5C
3'
1/
2" 1'
4"
1'
7" 8'
8"
A-620 3D
OPP.
2' - 0" 8"
1' - 6"
LINE OF EIFS BULKHEAD,
BEYOND
A-533 3C
A-533 5A
LINE OF PILASTER,
BEYOND
LINE OF SOFFIT,
BEYOND
STANDING SEAM METAL ROOF
OVER SELF ADHERING
UNDERLAYMENT OVER 5/8"
GLASS MAT GYPSUM ROOF
SHEATHING OVER METAL DECK
STRUCTURAL MEMBER,
REFER TO STRUCTURAL
DRAWINGS
EIFS SOFFIT, REFER
TO DETAIL
LINE OF ROOF,
BEYOND
TRANSLUCENT PANEL
EIFS BULKHEAD, REFER TO
DETAIL
2' - 8"
1'
/4
R E
FE
R
T O
E
LE
V
AT
IO
N
S
V A
R
IE
S 4'
5"
LINE OF PILASTER,
BEYOND
8" 2' - 0"
1' - 6"
2' - 5"
1ST FLOOR
100' - 0"
ADDITION LOWER LEVEL
83' - 0"
CAST STONE PARAPET CAP
MODIFIED BITUMEN ROOFING
OVER 1/2" RECOVERY BOARD
OVER 4" POLYISO INSULATION
OVER VAPOR RETARDER OVER
METAL ROOF DECK
STRUCTURAL STEEL
MEMBER, REFER TO
STRUCTURAL
DRAWINGS
SUSPENDED ACOUSTICAL
CEILING
2" RIGID FOUNDATION
INSULATION, EXTEND
MIN. 2'-0" UNDER SLAB
CONCRETE SLAB, REFER
TO STRUCTURAL
DRAWINGS
METAL STUD CEILING
BULKHEAD FRAMING,
REFER TO REFLECTED
CEILING PLANS FOR
DETAILS
PRE-FIN. BLAST RESISTANT
ALUM. & GLASS WINDOW
SYSTEM
2-1/2" RIGID INSULATION
OVER BITUMINOUS DAMP
PROOFING
2 -1/4" AIR SPACE
8" CMU WITH HORIZONTAL
GALV. METAL VENEER TIES
@ 16" o.c. MAX. REFER TO
STRUCTURAL DRAWINGS
FOR ADDITIONAL
REINFORCEMENT & GROUT
REQUIREMENTS
FACE BRICK VENEER
ELEVATED CONCRETE SLAB
OVER METAL DECK, REFER TO
STRUCTURAL DRAWINGS
STRUCTURAL STEEL
MEMBER, REFER TO
STRUCTURAL
DRAWINGS
RAMP METAL HANDRAIL,
REFER TO RAMP PLANS
& SECTIONS
1/2" SEALANT WITH
COMPRESSIBLE FILLER
CONCRETE
FOUNDATION, REFER
TO STRUCTURAL
DRAWINGS
EXTERIOR CONCRETE
SLAB, REFER TO
STRUCTURAL
DRAWINGS
A-620 4D
A-620 4A
A-620 3D
LINE OF COLUMN WRAP,
BEYOND
LINE OF COLUMN WRAP,
BEYOND
A-620 3A
A-530 4C
4'
8" 8'
4"
6'
0" 2'
8"
CORRIDOR
CORRIDOR
C105
CAST STONE BAND
CAST STONE BAND
BRICK SOILDER COURSE
BRICK ROWLOCK
COURSE
SIM.
V A
R
IE
S
FILL CMU CORES SOLID
WITH COURSE GROUT
BELOW INTERIOR SLAB
HEIGHT, TYP.
A-530 3A 2
D
2 3
C
A
B
SHEET
A N
SI
D
U . S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y
C K
D B
Y
D E
S
IG
N
ED
B Y
D
AT
E:
SI
ZE
S U
B M
IT
TE
D B
Y
PL
O
TT
ED
B Y:
PL
O
T D
AT
E:
D
ES
C R
IP
TI
O N
D
AT
E
C O
N
TR
A C
T N
O
M
AR
K A
P P
R
US Army Corps of Engineers New York District
D
ES
C R
IP
TI
O N
D
AT
E M
AR
K
A P
P R
SHEET
REFERENCE
NUMBER
OF
M
AY
N
YD
A
/E C
O
VE
R S
U
BM
IT
TE
D B
Y:
P
LO
T
D
AT
E:
W
6-
-D
-0
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
WO
OL
PE
RT
3 F ou nta ins P ark wa y Su ite
Fa irv iew
H eig hts
, IL
8-2
Te l: (
8)
2-7
Fa x:
(61
8)
2-0 ww w.
wo olp ert
.co m
9/
/2
:1 8:
A
M
9/
/2
:1 8:
A
M C
R ev it
Lo ca l\W es t P oi nt M
S_ D
EV
.rv t
W
AL
L S
EC
TI
ON
S
A-316
C A
S, G
R C
, C E
D
C
AS
W R
T
A -3
.d w g
J
U
LY
M
JL
M
JL
100% CONSTRUCTION
DOCUMENTS
W E
S T
P O
IN
T
M
ID
D L
E S
C H
O O
L A
D D
IT
IO
N A
N D
R E
N O
V A
T
IO
N W
E S
T P
O
IN
T, N
E W
Y O
R K
SCALE: 3/4" = 1'-0" A-302
5AWALL SECTION
SCALE: 3/4" = 1'-0" A-302
3AWALL SECTION
SCALE: 3/4" = 1'-0" A-204
2AWALL SECTION
0' 1' 2'6"
0' 1' 2'6"0' 1' 2'6"
A
M
EN
D M
EN
T
#0
A
U G
M
JL
A
M
EN
D M
E N
T
S E
P
M
JL
1' - 8 1/2"7' - 4 1/2"
3'
2"
8"
EXIST. OPENING
8"
P5.A P5.AP5.B
5A A-322
TYP. RUBBER
BUMPERS SET IN
METAL FRAME (BOTH
SIDES)
TYP. GALV. STEEL ANGLE
EDGE PROTECTION
AROUND DOCK LEVELER
PIT, REFER TO MFG'S
STANDARDS
INSET DOCK LEVELER
6' - 2"
6'
4"
LINE OF DOCK EDGE, REFER
TO PLAN
TYP. GALV. STEEL ANGLE
EDGE PROTECTION
AROUND DOCK LEVELER
PIT, REFER TO MFG'S
STANDARDS
D
1'
4" 6'
7/ 8"
4'
0" 3'
0"
2'
0" 2'
0"
3'
0" 4'
0"
6'
3/
4"
4' - 0" 4' - 0" 3' - 0" 2' - 0" 4' - 8"
BID OPTION #005
COLOR C02 SEALED
BID OPTION #005
COLOR INTEGRAL
CONCRETE SLAB -
FIELD COLOR
BID OPTION #005
COLOR C01 SEALED
8x16 DRAINAGE GAP
8x16 DRAINAGE GAP
8x16 DRAINAGE GAP
8'
0" 8'
0"
8'
0" 4'
0"
4'
8"
BASE BID
PROVIDE 17'-8" x 32'-8" CONCRETE
SLAB WITH TURNED DOWN EDGE
FOUNDATION AND STANDARD JOINT
WORK, REFER TO STRUCTURAL
DRAWINGS
17' - 8"
4C
A-322
BID OPTION #005
4C
A-322
BID OPTION #005
100' - 0"
100' - 0"
100' - 0" 100' - 0"99' - 8"
100' - 0"99' - 7"
NEW CLOSURE WALL TO
MATCH EXISTING
CONSTRUCTION, PLASTER
FINISH TO WRAP TO
EXISTING CORNER, P11A
NEW INFILL & CLOSURE WALL TO
MATCH EXISTING CONSTRUCTION,
PLASTER FINISH TO WRAP TO
EXISTING CORNER, P11A
(4) RELOCATED LOCKERS
LINE OF GYPSUM SOFFIT
ABOVE
6"
M.O.
3' - 4"1' - 5"
5' - 3"
2' - 1" 4' - 5 1/2"
1'
0"221
1'
2"
P9.A P7
P11A P11A P11A
P11AP9.A
P9.A
1' - 4"
M.O.
3' - 4"4"
5' - 0"
LINE OF SOFFIT
ABOVE
LINE OF SOFFIT
ABOVE
1' - 1 3/4"
M.O.
3' - 4"1' - 0"
5' - 5 3/4"
(8) RELOCATED
LOCKERS
NEW CLOSURE WALL TO
MATCH EXISTING
CONSTRUCTION,
PLASTER FINISH TO
WRAP TO EXISTING
CORNER, P11A
PLASTER FINISH TO
WRAP TO EXISTING
CORNER, TYP.
3'
0"
1'
2"
H J
LOCKABLE (PAIR)
4'-4" WIDE x 10'-0"
TALL CHAIN LINK
GATES, REFER TO
CIVIL DRAWINGS
27' - 0"
3'
8" 8'
8"
4'
8"
PROVIDE CHAIN LINK
ENCLOUSE CAP ABOVE
ENTIRE SHILLER
ENCLOSURE, REFER TO
SECTIONS / DETAILS
MIN.
4'-0" CLEAR
MIN.
4'-0" CLEAR
M
IN
4' -0
" C
LE
A R
M
IN
4' -0
" C
LE
A R
4' - 2"
6' - 4"
CHILLER ON HOUSE
KEEPING PAD, REFER TO
MECHANICAL DRAWINGS
SLOPED CONCRETE
SLAB, REFER TO
STRUCTURAL DRAWINGS
SLOPE
1/8":1'-0"
SLOPE
1/8":1'-0"
PROVIDE 8" WIDE x12" TALL WEEP VOIDS @ 4'-8" o.c. TO
DRAIN SLAB
WRAP BRICK
AT GATE
CORNERS,
TYP.
1A A-322
1A A-322
SIM.
10'-0" TALL MASONRY
PILASTERS WITH FACE
BRICK VENEER (BOTH
SIDES OF OPENING),
REFER TO STRUCTURAL
DRAWINGS
D
2 3
C
A
B
SHEET
A N
SI
D
U . S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y
C K
D B
Y
D E
S
IG
N
ED
B Y
D
AT
E:
SI
ZE
S U
B M
IT
TE
D B
Y
PL
O
TT
ED
B Y:
PL
O
T D
AT
E:
D
ES
C R
IP
TI
O N
D
AT
E
C O
N
TR
A C
T N
O
M
AR
K A
P P
R
US Army Corps of Engineers New York District
D
ES
C R
IP
TI
O N
D
AT
E M
AR
K
A P
P R
SHEET
REFERENCE
NUMBER
OF
M
AY
N
YD
A
/E C
O
VE
R S
U
BM
IT
TE
D B
Y:
P
LO
T
D
AT
E:
W
6-
-D
-0
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
WO
OL
PE
RT
3 F ou nta ins P ark wa y Su ite
Fa irv iew
H eig hts
, IL
8-2
Te l: (
8)
2-7
Fa x:
(61
8)
2-0 ww w.
wo olp ert
.co m
9/
/2
:2 7:
A
M
9/
/2
:2 7:
A
M C
R ev it
Lo ca l\W es t P oi nt M
S_ D
EV
.rv t
EN
LA
RG
ED
P
LA
NS
A-412
C A
S, G
R C
, C E
D
C
AS
W R
T
A -4
.d w g
J
U
LY
M
JL
M
JL
100% CONSTRUCTION
DOCUMENTS
W E
S T
P O
IN
T
M
ID
D L
E S
C H
O O
L A
D D
IT
IO
N A
N D
R E
N O
V A
T
IO
N W
E S
T P
O
IN
T, N
E W
Y O
R K
SCALE: 1/4" = 1'-0" A-102A
5AENLARGED PLAN
SCALE: 1/4" = 1'-0" A-101A
5BENLARGED PLAN
SCALE: 1/4" = 1'-0" A-102A
4AENLARGED PLAN @ ART PATIO
(BASE BID: PROVIDE STANDARD CONC. PATIO ONLY)
0' 2' 4' 8'
0' 2' 4' 8' 0' 2' 4' 8'
SCALE: 1/4" = 1'-0" A-103
5CENLARGED PLAN
0' 2' 4' 8'
SCALE: 1/4" = 1'-0" A-103
5DENLARGED PLAN
0' 2' 4' 8'
SCALE: 1/4" = 1'-0" A-101A
1AENLARGED CHILLER ENCLOSURE PLAN
A
M
EN
D M
EN
T
#0
A
U G
M
JL
A
M
EN
D M
E N
T
S E
P
M
JL
PRE-FINISHED VENTED METAL
PANEL SOFFIT, COLOR TO MATCH
ROOF
STAGGER MASONRY
EXPANSION BOLTS @ 16"
o.c., TYP.
CMU BOND BEAM, REFER TO
STRUCTURAL DRAWINGS
6" METAL STUD JOISTS
WITH R-19 BATT INSULATION
AND VAPOR RETARDER
PRE-FINISHED METAL FASCIA
WRAP WITH DRIP, COLOR TO
MATCH ROOF
PRE-FINISHED METAL
GUTTER, COLOR TO MATCH
ROOF
STEEL ANGLE, REFER TO
STRUCTURAL DRAWINGS
1' - 4"3' - 6"
CONTINUOUS PRE-FINISHED
ALUMINUM EAVE FLASHING
WITH DRIP EDGE
STANDING SEAM METAL
ROOF FIELD BEND END
OF ROOF PANELS OVER
ROOF EDGE, TYP.
3-5/8" METAL STUD SOFFIT FRAMING,
REFER TO SOFFIT MFG. FOR
SPACING REQUIREMENTS
STRUCTURAL MEMBERS,
REFER TO STRUCTURAL
DRAWINGS
CONTINUOUS P.T. WOOD
FASCIA NAILER
STEEL CHANNEL AND ANCHOR
BOLT, SET IN GROUT BED,
REFER TO STRUCTURAL
DRAWINGS
A-523 5A
SIM.
T/ MASONRY
99'-0"
5/8" GYP. BOARD
BASEMENT
87' - 0"
1x WOOD CAP, STAIN
1x WOOD MOLDING, STAIN
STEEL TUBE, REFER TO
STRUCTURAL DRAWINGS,
PAINT
ELEVATED
CONCRETE SLAB,
REFER TO
STRUCTURAL
DRAWINGS
BASE, AS
SCHEDULED
3'
4"
9"
3/
4"
CONTINUOUS 2x8
WOOD BLOCKING
8" CMU, PAINT WITH
HORIZONTAL
REINFORCEMENT @ 16" o.c., REFER TO STRUCTURAL
DRAWINGS
EXISTING MASONRY WALL
WATER CLOSET CARRIER, REFER
TO PLUMBING DRAWINGS
FORMED REINFORCED
CONCRETE STUB WALL, REFER
TO STRUCTURAL DRAWINGS
ELEVATED CONCRETE SLAB, REFER
TO STRUCTURAL DRAWINGS
EXISTING CONCRETE FLOOR
NEW WALL HUNG WATER
CLOSET, REFER TO PLUMBING
DRAWINGS
1' - 6"
V .I.
F.
2'
1/
2"
BASEMENT
87'-0"
EXISTING LOCKER ROOM
84'-3 1/2"
GRANULAR FILL, REFER TO
STRUCTURAL DRAWINGS
4' - 4"
1/
4"
GALV. STEEL FIN & EYE
BOLT, PAINTED, REFER TO
STRUCTURAL DRAWINGS
GLAV. STEEL ROD, PAINTED ,
REFER TO STRUCTURAL
DRAWINGS
STANDING SEAM METAL
ROOF OVER 5/8" GLASS-MAT
EXTERIOR SHEATHING OVER
METAL DECK. FIELD FOLD
END OF ROOF PANELS OVER
ROOF EDGE
PRE-FINISHED METAL
EAVE FASCIA, COLOR TO
MATCH ROOF
TUBE STEEL FRAME,
REFER TO
STRUCTURAL
DRAWINGS
PRE-FINISHED VENTED METAL
PANEL SOFFIT, COLOR TO
MATCH ROOF
GALV. STEEL FIN & EYE
BOLT, PAINTED, REFER TO
STRUCTURAL DRAWINGS
GROUT CMU CELLS
SOLID FOR ANCHOR
BOLT PLACEMENT,
REFER TO STRUCTURAL
DRAWINGS
A-523 3A
SIM.
SEALANT ALL AROUND
PENETRATIONS AT FACE
BRICK, TYP.
PRE-FINISHED METAL
REGLET RECIEVER
FLASHING - FILL JOINT
WITH BACKER ROD AND
SEALANT
GROUT CMU CELLS
SOLID FOR ANCHOR
BOLT PLACEMENT,
REFER TO STRUCTURAL
DRAWINGS
PRE-FINISHED METAL
FLASHING UP WALL MIN.
4" OVERLAP WITH
COUNTER-FLASHING, TYP.
8" M
IN
CONTINUOUS P.T. 2x
WOOD NAILER
CONTINUOUS P.T. 2x WOOD
NAILER DIE SOFFIT PANEL
INTO NAILER AND WRAP WITH
PRE-FINISHED METAL FASCIA
STEPPED PRE-FINISHED METAL
REGLET COUNTER-FLASHING OVER
PRE-FINISHED METAL ROOF
FLASHING, AT ADJACENT WALL
CONDITION BEYOND - 8" MIN.
HEIGHT
B/ STEEL
92'-0"
PRE-FINISHED REMOVEABLE
COUNTER-FLASHING WITH
FASTENERS @ 24" o.c. MAX.
WITH PRE-FIN METAL UPLIFT
CLIPS @ 30" o.c. MAX.
D
2 3
C
A
B
SHEET
A N
SI
D
U . S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
N
EW
Y O
R K ht tp w w w
.n an
.u sa ce .a rm y.
m il
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N
AM
E:
D W
N B
Y
C K
D B
Y
D E
S
IG
N
ED
B Y
D
AT
E:
SI
ZE
S U
B M
IT
TE
D B
Y
PL
O
TT
ED
B Y:
PL
O
T D
AT
E:
D
ES
C R
IP
TI
O N
D
AT
E
C O
N
TR
A C
T N
O
M
AR
K A
P P
R
US Army Corps of Engineers New York District
D
ES
C R
IP
TI
O N
D
AT
E M
AR
K
A P
P R
SHEET
REFERENCE
NUMBER
OF
M
AY
N
YD
A
/E C
O
VE
R S
U
BM
IT
TE
D B
Y:
P
LO
T
D
AT
E:
W
6-
-D
-0
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
WO
OL
PE
RT
3 F ou nta ins P ark wa y Su ite
Fa irv iew
H eig hts
, IL
8-2
Te l: (
8)
2-7
Fa x:
(61
8)
2-0 ww w.
wo olp ert
.co m
9/
/2
:5 2:
A
M
9/
/2
:5 2:
A
M C
R ev it
Lo ca l\W es t P oi nt M
S_ D
EV
.rv t
SE
CT
IO
N
DE
TA
IL
S
A-531
C A
S, G
R C
, C E
D
C
AS
W R
T
A -5
.d w g
J
U
LY
M
JL
M
JL
100% CONSTRUCTION
DOCUMENTS
W E
S T
P O
IN
T
M
ID
D L
E S
C H
O O
L A
D D
IT
IO
N A
N D
R E
N O
V A
T
IO
N W
E S
T P
O
IN
T, N
E W
Y O
R K
SCALE: 1 1/2" = 1'-0" A-311
5ACURVED SOFFIT DETAIL @ INFO CENTER
SCALE: 1 1/2" = 1'-0" A-302
2BLOBBY HALF WALL DETAIL
SCALE: 3/4" = 1'-0" 2AELEVATED LOCKER ROOM FLOOR DETAIL
SCALE: 1 1/2" = 1'-0" A-120A
5BDOCK CANOPY DETAIL
0' 1'6"3"
0' 1'6"3"
0' 1'6"3"0' 1'6"3"
A
M
EN
D M
E N
T
S E
P
M
JL
D
2 3
C
A
B
SHEET
A N
S I D
W
G
-0 9-
D -0
9-
C V0
U . S
. A R
M Y
EN
G
IN
E
ER
D
IS
TR
IC
T
N E
W Y
O R
K ht tp w w w .n an .u sa ce
.a rm y.
m il
S O
LI
C
IT
A
TI
O
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
E D
B Y:
D
AT
E:
S
IZ
E:
S U
B M
IT
TE
D B
Y:
P
LO
TT
E
D B
Y:
P
LO
T
D
AT
E:
D
ES
C
R
IP
TI
O
N D
AT
E
C O
N
TR
AC
T
N O
M
AR
K A
PP
R
US Army Corps of Engineers New York District
J
U
LY
D
ES
C R
IP
TI
O N
D
AT
E M
AR
K
A
PP
R
W
ES
T
PO
IN
T
M
ID
D
LE
S C
H O
O L
AD
D
IT
IO
N A
N D
R
EN
O V
AT
IO
N W
ES
T
PO
IN
T, N
EW
Y
O R
K
SHEET
REFERENCE
NUMBER
OF
2/
/2
3:
:4
PM
Fi le
P at h S
U
BM
IT
TE
D B
Y:
P
LO
T
D
AT
E:
M
A Y
N
Y D
A /E
C O
V E
R
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
100% CONSTRUCTION
DOCUMENTS
CG107
D M
B
D M
B
KL
S
MAINTENANCE/INSPECTION PROCEDURES
THE GENERAL CONTRACTOR SHALL SELECT UP TO THREE INDIVIDUALS WHO SHALL BE RESPONSIBLE FOR INSPECTIONS, MAINTENANCE AND REPAIR ACTIVITIES, AND FILLING OUT THE INSPECTION AND MAINTENANCE REPORT.
PERSONNEL SELECTED FOR INSPECTION RESPONSIBILITIES WILL RECEIVE TRAINING FROM THE SITE SUPERINTENDENT. THEY WILL BE TRAINED IN ALL THE INSPECTION AND MAINTENANCE PRACTICES NECESSARY FOR KEEPING THE EROSION AND SEDIMENT CONTROLS
USED ONSITE IN GOOD WORKING ORDER.
THE FOLLOWING INSPECTION AND MAINTENANCE PRACTICES SHALL BE USED TO MAINTAIN EROSION AND SEDIMENT CONTROLS:
ALL CONTROL MEASURES SHALL BE INSPECTED AT LEAST ONCE EACH WEEK AND FOLLOWING ANY RAINFALL EVENT OF 0.5 INCHES OR GREATER. DURING PERIODS OF EXTENDED RAINFALL, ALL MEASURES SHALL BE INSPECTED DAILY.
ALL MEASURES WILL BE MAINTAINED IN GOOD WORKING ORDER. IF A REPAIR IS NECESSARY, IT SHALL BE INITIATED WITHIN 24 HOURS
OF REPORT.
BUILT UP SEDIMENT WILL BE REMOVED FROM SILT FENCES AND STRAW BALE DIKES WHEN IT HAS REACHED ONE-THIRD THE HEIGHT
OF THE FENCE OR BALE.
SEDIMENTATION BASINS SHALL BE INSPECTED FOR DEPTH OF SEDIMENT, AND BUILT UP SEDIMENT SHALL BE REMOVED WHEN IT
REACHES 50 PERCENT OF THE DESIGN DEPTH OF THE BASIN.
TEMPORARY AND PERMANENT SEEDING AND PLANTING WILL BE INSPECTED FOR BARE SPOTS, WASHOUTS, AND HEALTHY GROWTH.
A MAINTENANCE INSPECTION REPORT SHALL BE MADE AFTER EACH INSPECTION. ALL INSPECTION REPORTS SHALL BE KEPT IN THE CONSTRUCTION OFFICE ON-SITE. IF THE PROVIDED FORM IS FILLED, ADDITIONAL FORMS SHALL BE USED AS NECESSARY UNTIL THE PROJECT IS COMPLETED. A REPORT SHALL BE COMPLETED FOR EACH OF THE REQUIRED INSPECTION INTERVALS.
NON-STORM WATER DISCHARGES
IT IS EXPECTED THAT SOME NON-STORM WATER DISCHARGES WILL OCCUR FROM THE SITE DURING THE CONSTRUCTION PERIOD. ALL NON-STORM WATER DISCHARGES SHALL BE DIRECTED TO THE SEDIMENT BASINS PRIOR TO DISCHARGE.
NON-STORM DISCHARGES EXPECTED INCLUDE WATER FROM WATER LINE FLUSHINGS, PAVEMENT WASH WATERS (WHERE NOT SPILLS OR LEAKS OF TOXIC OR HAZARDOUS MATERIALS HAVE OCCURRED), AND UNCONTAMINATED GROUNDWATER (FROM DEWATERING
EXCAVATION).
PRODUCT SPECIFIC PRACTICES
THE FOLLOWING PRODUCT SPECIFIC PRACTICES SHALL BE FOLLOWED ONSITE:
PETROLEUM PRODUCTS:
ALL ONSITE VEHICLES WILL BE MONITORED FOR LEAKS AND RECEIVE REGULAR PREVENTIVE MAINTENANCE TO REDUCE THE CHANCE OF LEAKAGE. PETROLEUM PRODUCTS WILL BE STORED IN TIGHTLY SEALED CONTAINERS WHICH ARE CLEARLY LABELED. ANY ASPHALT SUBSTANCES USED ONSITE WILL BE APPLIED ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS.
FERTILIZERS:
FERTILIZERS USED WILL BE APPLIED ONLY IN THE MINIMUM AMOUNTS RECOMMENDED BY THE MANUFACTURER. ONCE APPLIED, FERTILIZER WILL BE WORKED INTO THE SOIL TO LIMIT EXPOSURE TO STORM WATER. STORAGE WILL BE IN A COVERED SHED. THE CONTENTS OF ANY PARTIALLY USED BAGS OF FERTILIZER WILL BE TRANSFERRED TO A SEALABLE PLASTIC BIN TO AVOID SPILLS.
STORMWATER POLLUTION PREVENTION PLAN
PROJECT NAME:
WEST POINT MIDDLE SCHOOL
WEST POINT, NEW YORK
DESCRIPTION:
SOIL DISTURBING ACTIVITIES WILL INCLUDE: CLEARING AND GRUBBING; MASS GRADING, UNDERGROUND UTILITY INSTALLATION, FINE GRADING.
EROSION CONTROL MEASURES SHALL INCLUDE: INSTALLING A STABILIZED CONSTRUCTION ENTRANCE, PERIMETER SILT FENCE AND EARTH DIKES, INLET PROTECTION, EROSION CONTROL MAT ON SLOPES, TEMPORARY SEDIMENT CONTROL BASINS, TEMPORARY AND PERMANENT VEGETATION.
SITE AREA:
THE SITE IS APPROXIMATELY 3.04 ACRES.
THE SEQUENCE OF MAJOR ACTIVITIES SHALL BE AS FOLLOWS:
1 - INSTALL STABILIZED CONSTRUCTION ENTRANCE.
2 - CLEAR AND GRUB.
3 - INSTALL PERIMETER SILT FENCE.
4 - MASS GRADE
5 - STABILIZE DENUDED AREA AND STOCKPILES WITH TEMPORARY SEEDING WITHIN 14 DAYS OF THE LAST GRADING ACTIVITY IN THAT AREA.
6 - INSTALL STORM SEWER.
7 - INSTALL INLET PROTECTION AND SLOPE EROSION CONTROL BLANKETS.
8 - INSTALL ALL OTHER UNDERGROUND UTILITIES.
9 - CONSTRUCT BUILDING & PAVEMENT.
10 - COMPLETE FINE GRADING AND INSTALL PERMANENT SEEDING AND PLANTINGS
11 - WHEN ALL CONSTRUCTION ACTIVITY IS COMPLETE AND ALL VEGETATION IS ESTABLISHED, REMOVE ALL EROSION CONTROL MEASURES, AND RESEED
ANY AREAS DISTURBED BY THEIR REMOVAL.
NAME OF RECEIVING WATERS:
ALL STORMWATER IS CONTAINED WITHIN THE BASINS ON THE SITE.
OFFSITE VEHICLE TRACKING:
A STABILIZED CONSTRUCTION ENTRANCE SHALL BE PROVIDED TO HELP REDUCE VEHICLE TRACKING OF SEDIMENTS. PAVED STREETS ADJACENT TO THE SITE SHALL BE CLEANED DAILY OR MORE FREQUENTLY AS NECESSARY. CLEANING SHALL INCLUDE SCRAPING SIGNIFICANT AMOUNTS OF SOIL AND POWER
SWEEPING AS NEEDED TO REMOVE ANY EXCESS MUD, DIRT OR ROCK TRACKED FROM THE SITE.
TIMING OF CONTROL MEASURES
AS INDICATED IN THE SEQUENCE OF MAJOR ACTIVITIES AND THE STABILIZED CONSTRUCTION ENTRANCE SHALL BE CONSTRUCTED AS CLOSE TO FIRST IN THE SEQUENCE OF GRADING OPERATIONS AS PRACTICAL. AREAS WHERE CONSTRUCTION ACTIVITY WILL TEMPORARILY CEASE FOR MORE THAN 21 DAYS SHALL BE STABILIZED WITH TEMPORARY SEEDING AND MULCH WITH 14 DAYS OF THE LAST DISTURBANCE. ONCE CONSTRUCTION ACTIVITY CEASE PERMANENTLY IN AN AREA, THAT AREA SHALL BE STABILIZED WITH PERMANENT LANDSCAPING AS DIRECTED ON THE LANDSCAPE PLAN. SEDIMENT SHALL BE REMOVED FROM THE DETENTION BASINS, AND THE BASIN FINE GRADED, FLOW CHANNELS INSTALLED AND THE BASIN VEGETATED AS DIRECTED ON THE
LANDSCAPE PLAN.
THE CONTRACTOR SHALL INSPECT AND REMOVE ANY LOOSE MATERIAL THAT IS DEPOSITED IN THE FLOW LINES OF GUTTERS, DRAINAGE STRUCTURES, DITCHES, ETC. SUCH THAT THE NATURAL FLOW LINE OF WATER IS OBSTRUCTED. AT THE CONCLUSION OF CONSTRUCTION OPERATIONS, ALL DRAINAGE
STRUCTURES AND FLOW LINES SHALL BE FREE FROM DIRT AND DEBRIS.
AT THE CONCLUSION OF EACH DAY, THE CONTRACTOR SHALL INSURE POSITIVE SITE DRAINAGE TO AN AREA PROTECTED BY EROSION CONTROLS. SITE
DRAINAGE MAY BE ACHIEVED BY SHEET FLOW, STORM SEWERS, DITCHING, OR PUMPING.
CERTIFICATION OF COMPLIANCE WITH FEDERAL, STATE, AND LOCAL REGULATIONS
THE STORM WATER POLLUTION PREVENTION PLAN REFLECTS THE STATE OF NEW YORK REQUIREMENTS FOR STORM WATER MANAGEMENT AND EROSION AND SEDIMENT CONTROL. TO ENSURE COMPLIANCE, THIS PLAN WAS PREPARED IN ACCORDANCE WITH THE USEPA "STORM WATER MANAGEMENT FOR CONSTRUCTION ACTIVITIES - DEVELOPING POLLUTION PREVENTION PLANS AND BEST MANAGEMENT PRACTICES, SUMMARY GUIDANCE". THERE ARE NO OTHER APPLICABLE STATE OR FEDERAL REQUIREMENTS FOR SEDIMENT AND EROSION SITE PLANS (OR PERMITS) OR STORM WATER MANAGEMENT SITE
PLANS (OR PERMITS).
27 38
LENGTH (FT)
ST 1.1 - 18'
ST 3.1 - 21'
ST 4.1 - 10'
2 3
C
A
B
SHEET
A N
S I D
W
G
-0 9-
D -0
9-
C V0
U . S
. A R
M Y
EN
G
IN
E
ER
D
IS
TR
IC
T
N E
W Y
O R
K ht tp w w w .n an .u sa ce
.a rm y.
m il
S O
LI
C
IT
A
TI
O
N N
O
FI
LE
N
AM
E:
D W
N B
Y:
C
KD
B
Y:
D
ES
IG
N
E D
B Y:
D
AT
E:
S
IZ
E:
S U
B M
IT
TE
D B
Y:
P
LO
TT
E
D B
Y:
P
LO
T
D
AT
E:
D
ES
C
R
IP
TI
O
N D
AT
E
C O
N
TR
AC
T
N O
M
AR
K A
PP
R
US Army Corps of Engineers New York District
J
U
LY
D
ES
C R
IP
TI
O N
D
AT
E M
AR
K
A
PP
R
W
ES
T
PO
IN
T
M
ID
D
LE
S C
H O
O L
AD
D
IT
IO
N A
N D
R
EN
O V
AT
IO
N W
ES
T
PO
IN
T, N
EW
Y
O R
K
SHEET
REFERENCE
NUMBER
OF
2/
/2
3:
:4
PM
Fi le
P at h S
U
BM
IT
TE
D B
Y:
P
LO
T
D
AT
E:
M
A Y
N
Y D
A /E
C O
V E
R
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
100% CONSTRUCTION
DOCUMENTS
CS106
D M
B
D M
B
KL
S
15 38
2 3
C
A
B
SHEET
A N
S I D
U . S
. A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T
N E
W Y
O R
K ht tp w w w
.n an
.u sa ce .a rm y.
m il
S O
LI
C
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
S U
B M
IT
T
E D
B Y
P
LO
T T
E D
B Y
P
LO
T
D A
T E
D
E S
C R
IP
T
IO
N
D A
T E
C O
N T
R A
C T
N O
M A
R K
A P
P R
US Army Corps of Engineers
New York District
D E
S C
R
IP
T
IO
N D
A T
E M
A R
K A
P P
R
SHEET
REFERENCE
NUMBER
OF
M A
Y
N Y
D A
/E C
O V
E R
S U
B M
IT
T
E D
B Y
P
LO
T
D A
T E
W
6-
-D
-0
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
W
OO
LP
ER
T
Fo un ta in s
Pa rk wa y
Su ite
Fa irv ie w
He ig ht s, IL
8-
Te l:
(6
) 6
-7
Fa x:
(6
) 6
-0 ww w.
wo ol pe rt.
co m
/1
/2
:1
:2
P
M
8/ 1 9
/2
1:
: 2
P
M
C :\L oc al
R ev it F ile s\
W es t P o i nt M
S _L oc a l
_0 6-
0 7 -1
1.
rv t
RO
OM
F
IN
IS
H
SC
HE
DU
LE
IF601
C E
D
C E
D W
R T
IF
1.
dw g
A ug us t 2
M
JL
M
JL
100% CONSTRUCTION
DOCUMENTS
W E
S T
P O
IN
T
M
ID
D L
E S
C H
O O
L A
D D
IT
IO
N A
N D
R E
N O
V A
T
IO
N W
E S
T P
O
IN
T , N
E W
Y O
R K
ROOM FINISH SCHEDULE
Room Floors Walls Ceilings
RemarksNo. Name Floor Base N S E W Finish Height
117 AUDITORIUM CPT-2, EP-2 EXIST EXIST EXIST EXIST EXIST EXIST EXIST
121 PRINCIPAL WD VB WC-1 PT-9 PT-9 WC-1 ACT-1 9'-3" REPAIR AND REFINISH EXISTING WOOD FLOORING
121A CONFERENCE ROOM WD VB PT-1 WC-1 PT-1 PT-1 ACT-1 9'-3" REPAIR AND REFINISH EXISTING WOOD FLOORING 122 RECEPTION/ WAITING/ COPY WD VB PT-1 PT-4 PT-1 PT-1 ACT-1 9'-3" REPAIR AND REFINISH EXISTING WOOD FLOORING
122A ADMIN OFFICE WD VB WC-1 PT-9 PT-9 WC-1 ACT-1 9'-3" REPAIR AND REFINISH EXISTING WOOD FLOORING 122B SMSS WD VB WC-1 PT-9 PT-9 WC-1 ACT-1 9'-3" REPAIR AND REFINISH EXISTING WOOD FLOORING 122C STUDENT RECORDS WD VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-3" REPAIR AND REFINISH EXISTING WOOD FLOORING
123 SCIENCE SVT-1, SVT-3, SVT-4, SVT-5 VB PT-4, AP-1
(F1)
PT-4, AP-1 (F1) PT-4 PT-4 ACT-2 10'-4"
123A PREP ROOM SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
124 BAND CHORUS GUITAR RB-1, RB-2, RB-3, RB-4 VB WC-2, AP-1
(F1), BD-1
WC-2, AP-1 (F1),
BD-1
WC-2, AP-1
(F1), BD-1
WC-2, AP-1
(F1), BD-1
ACT-2, PD-1 17'-8"
124A INSTRUMENT STORAGE RB-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
124B PRACTICE RB-1 VB AP-1 (F1)
WC-2
AP-1 (F1) WC-2 AP-1 (F1)
WC-2
WC-2 ACT-2 9'-0"
124C OFFICE RB-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
125 ART PC-1, PC-2 VB PT-3 PT-3 PT-3 PT-3 ACT-2 10'-4"
125A WORK ROOM PC-1 VB PT-3 PT-3 PT-3 PT-3 ACT-1 9'-0"
125B GRAPHIC ARTS PC-1 VB PT-3 PT-3 PT-3 PT-3 ACT-2 9'-0"
125C KILN PC-1, VB PT-3 PT-3 PT-3 PT-3 ACT-1 9'-0"
126 GPC SVT-1, SVT-2, SVT-3, SVT-4 VB PT-3, AP-1
(F1)
PT-3, AP-1 (F1) PT-3 PT-3, AP-1
(F1)
ACT-2 10'-4"
127 GPC SVT-1, SVT-2, SVT-3, SVT-4 VB PT-3, AP-1
(F1)
PT-3, AP-1 (F1) PT-3, AP-1
(F1)
PT-3 ACT-2 10'-4"
128 GPC SVT-1, SVT-2, SVT-3, SVT-4 VB PT-3, AP-1
(F1)
PT-3, AP-1 (F1) PT-3, AP-1
(F1)
PT-3 ACT-2 10'-4"
129 SCIENCE SVT-1, SVT-3, SVT-4, SVT-5 VB PT-4, AP-1
(F1)
PT-4, AP-1 (F1) PT-4, AP-1
(F1)
PT-4 ACT-2 10'-4"
129A PREP ROOM SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
130 GPC SVT-1, SVT-2, SVT-3, SVT-4 VB PT-3 PT-3 PT-3, AP-1
(F1)
PT-3, AP-1
(F1)
ACT-2 10'-4"
131 SCIENCE SVT-1, SVT-3, SVT-4, SVT-5 VB PT-4, AP-1
(F1)
PT-4 PT-4, AP-1
(F1)
PT-4, AP-1
(F1)
ACT-2 10'-4"
141 CORRIDOR SVT-1 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-0" SEE BID OPTION NO. 1 ON FINISH PLANS.
200 COVERED WALKWAY -- -- -- -- -- -- -- --
C200 VESTIBULE SVT-1, WM-1 VB PT-1 PT-1 PT-1 PT-1 PT-EXP EXP SEE BID OPTION NO. 1 ON FINISH PLANS.
C201 CORRIDOR TER-1, TER-2, EXIST EXIST, TB-3 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 8'-10" C202 CORRIDOR EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 8'-10"
C203 VEST EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 EXIST EXIST
C204 CORRIDOR EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-7"/ 9'-8"
C204A JAN SC VB PT-1 PT-1 PT-1 PT-1 EXIST EXIST
C205 CORRIDOR WD VB PT-1 PT-1 PT-1 -- ACT-1 9'-3" REPAIR AND REFINISH EXISTING WOOD FLOORING
C206 VEST EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 EXIST EXIST
C207 CORRIDOR EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-7" C208 CORRIDOR EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-8"
E102.2 ELEV. TER-3 TB-4 -- -- -- -- -- --
JA04 JAN. SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
M107 DATA SDT-1 VB PT-1 PT-1 PT-1 PT-1 PT-EXP EXP
M108 WATER HEATER SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
S101.2 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 EXP EXP
S102.2 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 EXP EXP
S103.2 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-0" S104.2 STAIR EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST TOUCH UP PAINT AS REQUIRED FROM WALL
PLASTER REPAIR.
S106.2 STAIR ST-1, ST-2 VB PT-1 PT-1 PT-1 PT-1 ACT-2 10'-4"
T201 TOILET EXIST EXIST PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3, WT-4
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6" WALL TILE TO BE INSTALLED ON EAST WALL ONLY
WHERE INDICATED. RE: B1/IN404.
T202 TOILET EXIST EXIST PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3, WT-4
PT-1 PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T203 TLT CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T204 STAFF M. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T205 STAFF F. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T206 GIRLS CT-1, CT-2, CT-3 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3,
WT-4
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 9'-0"
T207 BOYS CT-1, CT-2, CT-3 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3,
WT-4
GWB - PT13 9'-0"
T208 STAFF M. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 9'-0"
T209 STAFF F. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 9'-0"
206 GPC SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2 9'-4"
207 GPC SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2 10'-0"
212 ELEV. LOBBY TER-3 TB-4 PT-1 PT-1 PT-1 -- ACT-2 9'-0"
215 BALCONY CPT-2, EP-2 EXIST EXIST EXIST EXIST EXIST EXIST EXIST
215A PROJECTOR SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
216 GPC SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2 9'-4"
217 GPC SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2 9'-4"
218 GPC SVT-1, SVT-2, SVT-3, SVT-4 VB PT-3 PT-3 PT-3 PT-3 ACT-2 9'-4"
220 WORK/ COPY SVT-1 VB PT-1 PT-9 PT-1 PT-1 ACT-1 9'-4"
220A STORAGE SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-4"
220B GUIDANCE OFFICE SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-2 9'-4"
220C CONF./ TESTING SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-2 9'-4"
221 GPC SVT-1, SVT-2, SVT-3, SVT-4 VB PT-3 PT-3 PT-3 PT-3 ACT-2 9'-4"
C301 CORRIDOR TER-1, TER-2, EXIST TB-3, EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 8'-0" C302 CORRIDOR EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 8'-0" C303 CORRIDOR EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 8'-0"
E102.3 ELEV. -- -- -- -- -- -- -- --
JA05 JANITOR EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXP
S101.3 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-7" S102.3 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-7"
T301 TOILET CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T302 TOILET EXIST EXIST PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3, WT-4
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6" WALL TILE TO BE INSTALLED ON EAST WALL ONLY
WHERE INDICATED. RE: B1/IN404.
T303 TOILET EXIST EXIST PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3, WT-4
PT-1 PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T304 TOILET CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
ROOM FINISH SCHEDULE
Room Floors Walls Ceilings
RemarksNo. Name Floor Base N S E W Finish Height
B1 TECH. SUPPORT SDT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 8'-1"
B2 SERVER ROOM SDT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B3 CUSTODIAL SC VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-7"
B6 TEACHER LOUNGE/ WORK
ROOM
SVT1, SVT-2, SVT-3, SVT-4 VB PT-1/ WT-5
THRU WT-12
PT-9 PT-1 PT-1 ACT-1 8'-6" SEE D5/IN404 FOR ELEVATION AT WALL TILE
B6A NURSE SVT1, SVT-2, SVT-3, SVT-4 VB PT-1/ PT-4 PT-1/ WT-5 THRU
WT-12
PT-1/ PT-4 PT-1 ACT-1 8'-6" CUBICLE CURTAIN PRVC-1. SEE A5/IN404 FOR
ELEVATION AT WALL TILE.
B6B UTILITIES EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXP
B7 VIDEO RECORDING AVT-1 VB PT-3, AP-1
(F1)
PT-3, AP-1 (F1) PT-3 PT-3, AP-1
(F1)
PIPE GRID @
CLG.
9'-0"
B7A ELEC. SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
B8 ELEV. LOBBY TER-3 TB-4 -- PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-1 9'-0"
B9 ELEV. LOBBY TER-3 TB-4 -- PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-1 9'-0"
B10 CONFERENCE ROOM SVT-1, SVT-2, SVT-3, SVT-4 VB PT-1 PT-1 PT-1 PT-1 ACT-1 8'-6"
B12 COMPUTER LAB SDT-1, SDT-2, SDT-3,
SDT-4
VB PT-3 PT-3 PT-3 PT-3 ACT-2 8'-11"
B12A OFFICE SDT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 8'-11"
B12B CONTROL / EDIT ROOM AVT-1 VB PT-3 PT-3 PT-3 PT-3 ACT-2 8'-6"
B14 LOBBY SVT-1, SVT-2, SVT-3, SVT-4 VB PT-9 PT-1 PT-1 PT-9 ACT-1 9'-0"
B14A STAFF WORK ROOM SVT-1, SVT-2, SVT-3, SVT-4 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B14B ITINERANT SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B14C ITINERANT - LOGISTICS
ASSISTANT
SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B14D CSC CONFERENCE AREA SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B15 GYM WD-2 EXIST EXIST EXIST EXIST EXIST EXIST EXIST REPAIR AND REFINISH EXISTING WOOD FLOOR
B16 INFORMATION CENTER CPT-1, RB-1, RB-2, RB-3,
RB-4
VB PT-5, PT-7 PT-5, AP-1 (F3),
AP-2
PT-6, PT-7,
AP-1 (F2),
AP-2
PT-6, PT-7,
AP-1 (F2),
AP-1 (F3),AP-2
ACT-2 VARIES
B16C ADMIN AREA RB-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B17 SCHOOL SUPPLY/ STORAGE
AREA
SC VB PT-1 PT-1 PT-1 PT-1 ACT-1 12'-0"
B17A OFFICE SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B17E FLAMMABLE STORAGE SC VB PT-1 PT-1 PT-1 PT-1 PT-EXP EXP
B18 SERVING LINE/ FOOD PREP EP-1 EB-1 PT-10 WT-5 THRU WT-12 PT-10 PT-10 MR-ACT 10'-0" SEE A3/IN404 FOR ELEVATION AT WALL TILE./ SEE
KITCHEN DRAWINGS FOR CORNER GUARD
LOCATIONS.
B18A DRY STORAGE EP-1 EB-1 PT-10 PT-10 PT-10 PT-10 MR-ACT 10'-0"
B18B REF/ FREEZER SC -- -- -- -- -- EXP EXP
B18C RECEIVING EP-1 EB-1 PT-10 PT-10 PT-10 PT-10 MR-ACT 10'-0"
B18D MANAGER'S OFFICE SVT-1 VB PT-1 PT-1 PT-1 PT-1 MR-ACT 9'-0"
B18E DISHWASH EP-1 EB-1 PT-10 PT-10 PT-10 PT-10 MR-ACT 10'-0"
B19 CAFETERIA AF-1 VB PT-3, AP-1
(F1)
PT-3, AP-1 (F1) PT-3, AP-1
(F1)
PT-3, AP-1
(F1)
ACT-2 12'-8"
B19B CAFETERIA STORAGE SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
B20 STOR. SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
B21 ELEVATOR EQUIPMENT
ROOM
SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP LOCATED AT GYM LEVEL
B22 STO SC VB PT-1 PT-1 PT-1 PT-1 EXIST EXIST
C101 CORRIDOR EXIST, TER-1, TER-2 EXIST, TB-3 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-0" C102 CORRIDOR EXIST, TER-1, TER-2 EXIST, TB-3 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-3"
C103 VEST EXIST EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 /
GWB-PT13
9'-0"/ 9'-4"
C104 VEST EXIST, WM-2 EXIST PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 9'-0" C105 CORRIDOR SVT-1 VB PT-1 PT-1 PT-1 PT-1 ACT-1 12'-0" SEE BID OPTION NO. 1 ON FINISH PLANS.
E102.1 ELEV. -- -- -- -- -- -- -- --
JA01 JANITOR EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXP
JA02 JAN. SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
M101 MECH EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXP
M101A MECH EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXP
M102 MECH SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
M103 ELEC SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
M104 DATA SDT-1 VB PT-1 PT-1 PT-1 PT-1 EXP EXP
M105 MECH SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
M106 MECH SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
S101.1 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 VARIES S102.1 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2 VARIES S103.1 STAIR ST-1, ST-2 VB PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 PT-1, PT-2 ACT-2/ PT13 9'-0"/ EXIST/
8'-0"
S104.1 STAIR EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXP TOUCH UP PAINT AS REQUIRED FROM WALL
PLASTER REPAIR.
S106.1 STAIR ST-1, ST-2, WM-1 VB PT-1 PT-1 PT-1 PT-1 ACT-2/ PT13 12'-8"/ VARIES
T102 BOYS LOCKER ROOM CT-1, CT-2, CT-3 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1 PT-1, WT-1,
WT-2, WT-3,
WT-4
GWB - PT13 8'-6"
T103 TLT. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T104 GIRLS LOCKER ROOM CT-1, CT-2, CT-3 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1 PT-1, WT-1,
WT-2, WT-3,
WT-4
GWB - PT13 8'-6"
T105 STAFF F. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T105A STAFF M. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 8'-6"
T106 GIRLS CT-1, CT-2, CT-3 TB-1, PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3,
WT-4
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 9'-0"
T107 BOYS CT-1, CT-2, CT-3 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3,
WT-4
GWB - PT13 9'-0"
T108 STAFF M. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 9'-0"
T109 STAFF F. CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 9'-0"
T210 JAN. SC VB PT-1 PT-1 PT-1 PT-1 EXP EXP
T213 LOCKERS CT-1, CT-2 TB-1 PT-1 PT-1 PT-1 PT-1 GWB - PT13 9'-0"
T214 TLT CT-1, CT-2 TB-1 PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1, WT-2,
WT-3
PT-1, WT-1,
WT-2, WT-3
PT-1, WT-1,
WT-2, WT-3
GWB - PT13 9'-0"
102 LI-MM SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3, PT-3, WT-5
THRU WT-12
ACT-2/GWB-PT
9'-3" SEE A3/IN404 FOR ELEVATION AT WALL TILE.
107 LI-S SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2/
GWB-PT13
9'-3"/ 8'-6"
107A HOME LIVING AREA SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3, WT-5
THRU WT-12
ACT-2 9'-3" SEE ELEV. 5B/A-421 & DETAIL D4/IN404
108 GPC SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2 /
GWB-PT13
9'-3"
109 STAFF WORK ROOM SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
110 COMPUTER LAB SDT-1, SDT-2, SDT-3,
SDT-4
WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2 8'-11"
111A STOR. SVT-1 WD -PT12 PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
114 GPC SVT-1, SVT-2, SVT-3, SVT-4 WD -PT12 PT-3 PT-3 PT-3 PT-3 ACT-2 9'-0"
115A STAGE EXIST EXIST EXIST EXIST EXIST EXIST EXIST EXIST
116 ELEV. LOBBY TER-3 TB-4 PT-1 PT-1 PT-1 PT-1 ACT-2 9'-0"
A
M E
N D
M E
N T
A
U G
A M
S
A M
E N
D M
E N
T
A U
G
A
M S
A
M E
N D
M E
N T
A U
G
A
M S
2 3
2 3
C
A
B
SHEET
A N
S I D
U . S
. A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T
N E
W Y
O R
K ht tp w w w
.n an
.u sa ce .a rm y.
m il
S O
LI
C
IT
A
T
IO
N N
O
F
IL
E N
A M
E
D W
N B
Y
C K
D B
Y
D E
S
IG
N E
D B
Y
D A
T E
S
IZ
E
S U
B M
IT
T
E D
B Y
P
LO
T T
E D
B Y
P
LO
T
D A
T E
D
E S
C R
IP
T
IO
N
D A
T E
C O
N T
R A
C T
N O
M A
R K
A P
P R
US Army Corps of Engineers
New York District
D E
S C
R
IP
T
IO
N D
A T
E M
A R
K A
P P
R
SHEET
REFERENCE
NUMBER
OF
M A
Y
N Y
D A
/E C
O V
E R
S U
B M
IT
T
E D
B Y
P
LO
T
D A
T E
W
6-
-D
-0
THIS BAR IS ONE INCH ON
ORIGINAL DRAWING
IF NOT ONE INCH ON THIS
SHEET, ADJUST SCALES
ACCORDINGLY
0 1"
W
OO
LP
ER
T
Fo un ta in s
Pa rk wa y
Su ite
Fa irv ie w
He ig ht s, IL
8-
Te l:
(6
) 6
-7
Fa x:
(6
) 6
-0 ww w.
wo ol pe rt.
co m
/1
/2
:1
:2
P
M
8/ 1 9
/2
1:
: 2
P
M
C :\L oc al
R ev it F ile s\
W es t P o i nt M
S _L oc a l
_0 6-
0 7 -1
1.
rv t
RO
OM
F
IN
IS
H
LE
GE
ND
IF602
D es ig ne r
H A
L A
M S
IF
2.
dw g
A ug us t 2
A M
S
A M
S
100% CONSTRUCTION
DOCUMENTS
W E
S T
P O
IN
T
M
ID
D L
E S
C H
O O
L A
D D
IT
IO
N A
N D
R E
N O
V A
T
IO
N W
E S
T P
O
IN
T , N
E W
Y O
R K
Flooring
PC-1 (Polished Concrete Dye - Accent) MFG: Scofield Product: Formula One/ Liquid Dye Color: Inca Gold Number: 1435 Contact: 1-800-800-9900
PC-2 (Polished Concrete Dye - Accent) MFG: Scofield Product: Formula One/ Liquid Dye Color: Storm Cloud Number: 3055 Contact: 1-800-800-9900
SC (Sealed Concrete) MFG: Scofield Product: Formula One/ Liquid Dye Color: Storm Cloud Number: 3055 Contact: 1-800-800-9900
Carpet
CPT-1 (Information Center) MFG: Lees Carpet Type: Broadloom Pattern: Take Note GT090 Color: Prominent 228 Width: 12' roll Contact: Patrick Kelly (615) 631-9097
CPT-2 (Auditorium + Balcony) MFG: Lees Carpet Type: Broadloom Pattern: Take Note GT090 Color: Brilliant 312 Width: 12' roll Contact: Patrick Kelly (615) 631-9097
Resilient Flooring
SVT-1 (Solid Vinyl Tile - Field) MFG: Johnsonite Pattern: Granit Color: Lacey Pearl W Number: 422 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SVT-2 (Solid Vinyl Tile - Accent) MFG: Johnsonite Pattern: Granit Color: Sea Stone Number: 722 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SVT-3 (Solid Vinyl Tile - Accent) MFG: Johnsonite Pattern: Granit Color: Homing Pigeon Number: 383 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SVT-4 (Solid Vinyl Tile - Accent) MFG: Johnsonite Pattern: Granit Color: After Midnight B Number: 384 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SVT-5 (Solid Vinyl Tile - Accent) MFG: Johnsonite Pattern: Granit Color: Acadia Number: 426 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SDT-1 (Static Disipative Tile) MFG: Johnsonite Pattern: Granit SD Color: Full Moon Number: 710 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SDT-2 (Static Disipative Tile) MFG: Johnsonite Pattern: Granit SD Color: Tapestry Number: 715 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SDT-3 (Static Disipative Tile) MFG: Johnsonite Pattern: Granit SD Color: Smokey WG Number: 712 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
SDT-4 (Static Disipative Tile) MFG: Johnsonite Pattern: Granit SD Color: Kettle Black B Number: 713 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
AVT-1 (Acoustical Vinyl Tile) MFG: Johnsonite Pattern: Granit Acoustiflor Color: Lacey Pearl Number: 422 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
Concrete
Partitions
PT-1 (Paint - Field) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Decor White Number: SW 7559 Quality: Eggshell
PT-2 (Paint - Corridor Wainscot) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Light French Gray Number: SW 0055 Quality: Eggshell
PT-3 (Paint - GPC) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Concord Buff Number: SW 7684 Quality: Eggshell
PT-4 (Paint - Accent) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Honeydew Number: SW 6428 Quality: Eggshell
PT-5 (Paint - Information Center) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Bamboo Shoot Number: SW 7733 Quality: Eggshell
PT-6 (Paint - Information Center) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Gris Number: SW 7659 Quality: Eggshell
PT-7 (Paint - Information Center) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Rustic Adobe Number: SW 7708 Quality: Eggshell
PT-8 (Paint - Information Center) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Bee's Wax Number: SW 7628 Quality: Eggshell
PT-9 (Paint - Admin. Area) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Sociable Number: SW 6359 Quality: Eggshell
PT-10 (Paint - Kitchen) MFG: Sherwin Williams Type: Pro-Industrial High Performance Epoxy Color: Aesthetic White Number: SW 7035 Quality: Eggshell
PT-11 (Paint - Lockers) MFG: Sherwin Williams Type: Promar 200 Interior (B33 Series) Color: Light French Gray Number: SW 0055 Quality: Alkyd eg-shel enamel
PT-12 (Paint - Door Frames/Wood Trim) MFG: Sherwin Williams Type: Promar 200 Interior (B33 Series) Color: Peppercorn Number: SW7674 Quality: Alkyd eg-shel enamel
WT-2 (Wall Tile/ Glazed Porcelain - Accent MFG: DaleTile Pattern: Colour Scheme Color: Luminary Gold Number: B911 Size: 6"x6" Grout: GT-1 Grout Joint: 3/16" Contact: Mike Quant (515) 252-0212
WT-3 (Wall Tile/ Glazed Porcelain - Field) MFG: DaleTile Pattern: Colour Scheme Color: Desert Gray Number: B905 Size: 6"x6" Grout: GT-1 Grout Joint: 3/16" Contact: Mike Quant (515) 252-0212
WT-4 (Wall Tile/ Glazed Porcelain - Accent) MFG: DaleTile Pattern: Coastal Keystones Color: Tropical Tunder Number: CK88 Size: 1'x1' sheets Grout: GT-1 Grout Joint: N/A Contact: Mike Quant (515) 252-0212
WT-5 (Wall Tile - Serving Line) MFG: American Olean Pattern: Bright Color: Smokey Quartz Number: 0047 Size: 6"x6" Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
WT-6 (Wall Tile - Serving Line) MFG: American Olean Pattern: Matte Color: Matte Smokey Quartz Number: 0028 Size: 6"x6" Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
WT-7 (Wall Tile - Serving Line) MFG: American Olean Pattern: Bright Color: Light Smoke Number: 0042 Size: 6"x6" Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
WT-8 (Wall Tile - Serving Line) MFG: American Olean Pattern: Matte Color: Matte Light Smoke Number: 0004 Size: 6"x6" Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
WT-9 (Wall Tile - Serving Line) MFG: American Olean Pattern: Brights Color: Gloss Black Number: 0049 Size: 6"x6" Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
WT-10 (Wall Tile - Serving Line) MFG: American Olean Pattern: Matte Color: Matte Black Number: 0064 Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
WT-11 (Wall Tile - Serving Line) MFG: American Olean Pattern: Brights Color: Cappuccino Number: 0078 Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
Wall Tile continued
MiscellaneousCeilings
PT-13 (B.O. Soffits & GWB Ceilings ) MFG: Sherwin Williams Type: ProGreen 200 Latex Color: Extra White Number: SW7006 Quality: Flat
Painted Ceiling
ACT-1 (General) MFG: Armstrong Type: Fine Fissured Color: White Number: 1728 Edge: Square Lay-In Size: 2' x 2' x 5/8" Grid: GRID 1 Contact: David Hovekamp (314) 703-9400
ACT-2 (Acoustics) MFG: Armstrong Type: Fine Fissured High Acoustics Color: White Number: 1713 Edge: Square Lay-In Size: 2' x 2' x 3/4" Grid: GRID 1 Contact: David Hovekamp (314) 703-9400
MR-ACT (Kitchen Area) MFG: Armstrong Type: Clean Room VL Color: White Number: 868 Edge: Square Lay-In Size: 24"x24"x5/8" Grid: GRID 2 Contact: 877-ARMSTRONG
Lay - In Ceiling
Ceiling Grid
GRID-1 (General) MFG: Armstrong Type: Prelude XL 15/16" Exposed Tee Color: White Contact: David Hovekamp (314) 703-9400
GRID-2 (Kitchen) MFG: Armstrong Type: 15/16" Co-Extruded Clean Room Color: White Contact: David Hovekamp (314) 703-9400
RB-1 (Rubber Tile - Accent) MFG: Johnsonite Pattern: Eco-Shell Rubber Tile w/ Cork Color: Mars Rock Number: HRTEC-DH9 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
RB-2 (Rubber Tile - Accent) MFG: Johnsonite Pattern: Eco-Shell Rubber Tile w/ Cork Color: Sandstorm Number: HRTEC-DH7 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
RB-3 (Rubber Tile - Accent) MFG: Johnsonite Pattern: Eco-Shell Rubber Tile w/ Cork Color: Deep Sea Number: HRTEC-DP4 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
RB-4 (Rubber Tile - Accent) MFG: Johnsonite Pattern: Eco-Shell Rubber Tile w/ Cork Color: Timber Number: HRTEC-DP3 Size: 24"x24" Contact: Michelle Lebbing (314) 249-9810
EP-1 (Epoxy - Kitchen) MFG: Dura-A-Flex Inc.
Type: Shop Floor with Dur-A-Glaze Color: Medium Gray Finish: Non-skid Thickness: 1/16" - 1/4" Contact: Jay Martin (860) 944-6178
EP-2 (Epoxy - Auditorium) MFG: Dura-A-Flex Inc.
Type: ArmorTop with Dur-A-Gard Color: Match Existing Finish: Satin Pigmented (w/grit) Thickness: N/A Contact: Jay Martin (860) 944-6178
VB-1 (Vinyl Base) MFG: Johnsonite Color: Charcoal Number: 20 Size: 4" Cove Contact: Michelle Lebbing (314) 249-9810
TB-1 (Tile Cove Base - Glazed Porcelain) MFG: DaleTile Type: Colour Scheme Color: Desert Gray Number: B905 / P36C9TB Size: 6"x12" (Tile Cove Out Corner) MFG: DaleTile Type: Colour Scheme Color: Desert Gray Number: B905 / PC-36C9TB Size: 1"x6" Grout: GT-1 Contact: Mike Quandt (515) 252-0212
TB-2 (Sanitary Tile Cove Base - Serving Line) MFG: American Olean Type: Matte Color: Matte Smokey Quartz Number: 0028/ SCRL-3619T Size: 6"x6" Grout: GT-1 Contact: Julie Zobel (314) 971-6582
TB-3 (Terrazzo Integral Base - Corridor) MFG: Wausau Tile, INC.
Color: Match Existing (black) Number: N/A Contact: Mike Quant (515) 252-0212
* Chamfered edge, factory ground & polished finish
TB-4 (Terrazzo Integral Base - Elevator) MFG: Wausau Tile, INC.
Color: Meteor Number: TZ18 Contact: Mike Quant (515) 252-0212
* Chamfered edge, factory ground & polished finish
EB-1 (Epoxy Intergral Base - Kitchen) MFG: Dura-A-Flex Inc.
Type: 4" Cove Base Color: Medium Gray Contact: Jay Martin (860) 944-6178
Resilient Flooring continued Hard Flooring continued
WT-1 (Wall Tile/ Glazed Porcelain - Field) MFG: DaleTile Pattern: Colour Scheme Color: Desert Gray Number: B905 Size: 12"x12" Grout: GT-1 Grout Joint: 3/16" Contact: Mike Quandt (515) 252-0212
METAL TRIM (@ Tile Wainscot) MFG: Schluter Pattern: Jolly Color: Brushed Chrome Anodized Aluminum Number: ACGB Thickness: 5/16" Contact: 1-800-472-4588
Wall Tile continued Solid Surface
SS-1 (Rest Room Counter ) MFG: Wilsonart Color: Arctic Melange Number: 9070 ML Thickness: 1/2" Size: 30"x145" Contact: Richard Yates (636) 321-2016
Plastic Laminate
PL-1 (Counter Tops) MFG: Wilsonart Color: Silicon EV Number: 4811-60 Finish: Matte Contact: Richard Yates (636) 321-2016
PL-2 (Cabinets) MFG: Wilsonart Color: Fonthill Pear Number: 10745-60 Finish: Matte Contact: Richard Yates (636) 321-2016
Toilet Partitions
TP-1 (Restrooms) MFG: Marlite Type: Phenolic Color: Formica Mineral Spa Number: 6920-58 Contact: (330) 343-6621
Rubber Flooring
Athletic Flooring
AF-1 (Cafeteria) MFG: Johnsonite Pattern: Training Color: Golden Maple Number: 9002 Roll Width: 6'-6" Weldrod: 1291368 Contact: Michelle Lebbing (314) 249-9810
Terrazzo
Base
CT-1 (Floor Tile / Glazed Porcelain - Field) MFG: DaleTile Pattern: Colour Scheme Color: Desert Gray Number: B905 Size: 6"x6" Grout: GT-1 Grout Joint: 3/16" Contact: Mike Quant (515) 252-0212
CT-2 (Floor Tile / Glazed Porcelain - Accent) MFG: DaleTile Pattern: Colour Scheme Color: Desert Gray Speckle Number: B931 Size: 6"x6" Grout: GT-1 Grout Joint: 3/16" Contact: Mike Quant (515) 252-0212
CT-3 (Floor Tile/ Glazed Porcelain - Accent) MFG: DaleTile Pattern: Colour Scheme Color: Black Speckle Number: B927 Size: 6"x6" Grout: GT-1 Grout Joint: 3/16" Contact: Mike Quant (515) 252-0212
Porcelain Tile
Epoxy Flooring
Paint
PD-1 (Pyramidal Diffuser - Band Room Ceiling) MFG: Golterman & Sabo Product: Pyramidal Diffuser (BCD) Size: See Ceiling Plans Core: CDA Finish: Textured White Contact: Brian Shuh (800) 781-2036
GT-1 (Grout) MFG: Mapei Type: Kerapoxy Color: Silver Number: 27 Contact: (800) 992-6273
Grout
PL-3 (Restroom Counter Top Skirt) MFG: Formica Color: Mineral Spa Number: 6920-58 Finish: Matte Contact: Richard Yates (636) 321-2016
PL-4 (Chemical-Resistant Countertop) MFG: Wilsonart Color: Silicon EV Number: 4811-60 Finish: Matte Type: 390 Contact: Richard Yates (636) 321-2016
PL-5 (Chemical-Resistant Cabinet) MFG: Wilsonart Color: Fonthill Pear Number: 10745-60 Finish: Matte Type: 390 Contact: Richard Yates (636) 321-2016
PL-6 (Reception Countertop) MFG: Wilsonart Color: Deepstar Agate Number: 1815-60 Finish: Matte Contact: Richard Yates (636) 321-2016
WC-1 (Wallcovering - Administration) MFG: Maharam Pattern: Niche 398620 Color: 203 Cocoon 3 Width: 54" Contact: Amber Kramer (314) 443-9573
WC-2 (Acoustical Wallcovering - Band/Practice) MFG: D.L. Couch Pattern: Waterbrush Color: Buttermilk AWH-14 Width: 54" Contact: Christie Lewis (314) 422-0339
Wallcovering
Wall Tile
Ceiling Diffusers
Edge Band
EB-1 (Edge Band for PL-1) MFG: Wilsonart Name: Silicon EV Pattern: 9558 Size: 15/16" x .018"
Epoxy Resin Surface
ER-1 (Science Room Countertops) MFG: ChemTops Color: Black Edge: ClassicTop Bevel Edge Thickness: 1"
WT-12 (Wall Tile - Serving Line) MFG: American Olean Pattern: Matte Color: Matte Cappuccino Number: 0009 Grout: GT-1 Grout Joint: 1/16" Contact: Julie Zobel (314) 971-6582
Hard Wood Flooring - Refinish
WD (Varnish for Wood Floor) MFG: Sherwin Williams Name: Wood Classics Polyurethane Varish
High Gloss Clear Number: A67V1
Entry Matt System
WM-1 (Walk-Off Mat) MFG: Construction Specialities Style: PediGrid G1 Frame: Level Base Frame w/ Drain Pan Tread: Recycled Rubber (RR) Color: Cole Porter Size: Varies, See Finish Drawings
A
M E
N D
M E
N T
A U
G
A
M S
A
M E
N D
M E
N T
A U
G
A
M S
Gym Hard Wood Flooring - Refinish
WD-2 ( Urethane Gym Finish) MFG: MPC Maintenance Solutions…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .