PANELBOARD SCHEDULE

PANEL: 120/ 208 VOLTS 3 PHASE 4 W

AMP MAINS:

MOUNTING : X SURFACE X GROUND BAR X LUGS

FLUSH TWO SECTION BREAKER

BRANCH BREAKERS

AMP. CIR. LEFT PHASE RIGHT PHASE CIR. AMP.

ITEM POLE RAT. NO. A B C A B C NO. RAT. POLE ITEM

Recepts., Test Stand 1 1 20 1 0.30 0.30 2 20 1 Recpt., Test Stand 3

3 3.60 3.60 4

Disconnect 1, Test Stand 1 3 60 5 3.60 3.60 6 60 3 Disconnect 1, Test Stand 3

7 3.60 3.60 8

9 1.80 10

Disconnect 2, Test Stand 1 3 30 11 1.80 12 30 3 Disconnect 2, Test Stand 3

13 1.80 1.80 14

15 1.80 1.80 16

Disconnect 3, Test Stand 1 3 30 17 1.80 1.80 18 30 3 Disconnect 3, Test Stand 3

19 1.80 1.80 20

Recepts., Test Stand 2 1 20 21 0.30 0.30 22 20 1 Recpt., Test Stand 4

23 3.60 3.60 24

Disconnect 1, Test Stand 2 3 60 25 3.60 3.60 26 60 3 Disconnect 1, Test Stand 4

27 3.60 3.60 28

29 1.80 1.80 30

Disconnect 2, Test Stand 2 3 30 31 1.80 1.80 32 30 3 Disconnect 2, Test Stand 4

33 1.80 1.80 34

35 1.80 1.80 36

Disconnect 3, Test Stand 2 3 30 37 1.80 1.80 38 30 3 Disconnect 3, Test Stand 4

39 1.80 1.80 40

Spare 1 20 41 - - 42 1 20 Spare

14.70 14.70 14.40 14.70 12.90 12.60

29.40 27.60 27.00 TOTALS, KW

FEEDER: TOP

X BOTTOM TOTAL CONN. LOAD 84,000 WATTS

FEED THRU LUGS TOTAL CONN. LOAD 233 AMPS

INTEG. EQUIP. RATING AMPS RMS SYM.

RP1

LOCATION: Gun Shop Mech Room 10,000

PANELBOARD SCHEDULE

PANEL: 254/ 440 VOLTS 3 PHASE 4 W

AMP MAINS:

MOUNTING : X SURFACE X GROUND BAR LUGS

FLUSH TWO SECTION X BREAKER

BRANCH BREAKERS

AMP. CIR. LEFT PHASE RIGHT PHASE CIR. AMP.

ITEM POLE RAT. NO. A B C A B C NO. RAT. POLE ITEM

- 5.10

Surge Protective Device 3 30 1 - 5.10 2 30 3 Test Stand 1

- 5.10

- 5.10

Spare 3 20 3 - 5.10 4 30 3 Test Stand 2

- 5.10

- 5.10

Spare 3 20 5 - 5.10 6 30 3 Test Stand 3

- 5.10

- 5.10

Space Only 3 7 - 5.10 8 30 3 Test Stand 4

- 5.10

Space Only 3 9 - - 10 30 3 Spare

Space Only 3 11 - - 12 30 3 Spare

Space Only 3 13 - - 14 30 3 Spare

0.00 0.00 0.00 20.40 20.40 20.40

20.40 20.40 20.40 TOTALS, KW

FEEDER: TOP

X BOTTOM TOTAL CONN. LOAD 61,200 WATTS

FEED THRU LUGS TOTAL CONN. LOAD 80 AMPS

INTEG. EQUIP. RATING AMPS RMS SYM.

PP1

LOCATION: Gun Shop Mech Room 10,000

BASIS OF DESIGN ADDITIONAL

TYPE DESCRIPTION (BY SERIES AND/OR APPROVED VOLTS REMARKS WATTS

PART NUMBER MFR. (BY SERIES) NO. TYPE PROPERTIES NO. TYPE METHOD HEIGHT

A High Bay Flourescent, Specular Reflector with Wire Guard Lithonia FGB24 6 6 -

T5HO,

Amalgam, 3500K

2-3L

Electronic

Program start, Low Harmonic

120 Pendant 26'-0" Provide swivel type pendant hangers complete with safety cable attached to purlin.

B 4' Industrial Flourescent Light Fixture with 10% Up-light Lithonia AF Series

Day-Brite CFI-10

Metalux DIM Series

Columbia KL Series

2 32W T8, 3500ºK 1

Electronic

Program start, Low Harmonic

120 Suspended Varies Provide Chain Hangers and Wire Guard 64

C Same as Type B except 8', 4-lamp 4 32W T8, 3500ºK 2 Rapid Start, Low Harmonic 120 Wall 8'-6" Bracket Mounted on Wall 128

D 2' x 4' Flouresent Troffer with White Steel Doorframe, 0.125" thick A12 Acrylic Lens

Lithonia #25P8-4-332-

A12-GEB10IS Series

Equivalent Metalux, Daybrite, or Columbia.

3 32W T8, 3500ºK 1

Electronic

Program start, Low Harmonic

120 Lay in White Steel Door frame, 0.125" thick A12

Acrylic Lens

F Outdoor Wall Pack Lithonia TWRS 1 100W Metale Halide 1

High

Reactance, High Power

Factor

120 Wall See Arch.

Drawings.

Complete with Photocell. Consistant with

LEED goals and Green Globe Criteria

G Building Mounted Flood Lighting Hubbell SLS Series 2 400W MH 2 Pulse Start 120

Twin Wall

Bracket

Support

Complete with adjustable mounting knuckles, and photocells

E

Exit Sign, thermoplastic housing, self powered emergency with LED lamps, wall, ceiling or pendant mounted as required. Directional arrows as indicated on the plans

Lithonia Quantum McPhilben CTX Series

Hubbell NV3

- - LED - - 120 - Varies 12

EL

Emergency Light Unit, 12-volt, Dual Light Head Unit with lron calcium batteries, min. 12-watt sealed beam lamps, 90 minute light output to end voltage of 87.5%. Provide a dual light head fixture suitable for outdoor use, powered from indoor unit, where shown on the drawings.

Lithonia Quantum McPhilben CTX Series

Hubbell NV

- - Incandescent - - 120 Wall 7"-8" AFF

Provide a unit with additional capacity for units with dual heads located outdoors.

FIXTURE

MOUNTING

LIGHTING FIXTURE SCHEDULE

LAMPS

BALLAST/

TRANSFORMER

PANELBOARD SCHEDULE

PANEL: 120/ 208 VOLTS 3 PHASE 4 W

AMP MAINS:

MOUNTING : X SURFACE X GROUND BAR LUGS

FLUSH X TWO SECTION X BREAKER

BRANCH BREAKERS

AMP. CIR. LEFT PHASE RIGHT PHASE CIR. AMP.

ITEM POLE RAT. NO. A B C A B C NO. RAT. POLE ITEM

1 - 3.00 2

Surge Protective Device 3 30 3 - 3.00 4 60 3 Fork Lift Battery Charging Station

5 - 3.00 6

High Bay Lighting 1 20 7 1.30 0.20 8 20 1 Fire Alarm Panel*

High Bay Lighting 1 20 9 1.30 1.20 10 20 1 Exit Signs

High Bay Lighting 1 20 11 1.30 0.45 12 20 1 Recepts., Work Bench

High Bay Lighting 1 20 13 1.30 0.45 14 20 1 Recepts., Work Bench

High Bay Lighting 1 20 15 1.30 3.00 16 50 1 Recepts., Work Bench

High Bay Lighting 1 20 17 0.65 3.00 18 50 1 Recepts., Work Bench

Lighting, Rooms 103 & 104 1 20 19 0.96 0.30 20 20 1 Recepts., Gun Work Room

Lighting, Rooms 106, 7, 8, 9 & 10 1 20 21 1.06 0.45 22 20 1 Recepts., Wrk Rm & Spec.Proj. Rm

Lighting, Work Bench 1 20 23 0.45 24 20 1 Recepts., Wrk Rm & Spec.Proj. Rm

Dock Lighting 1 20 25 0.92 0.45 26 20 1 Recepts., Special Roj Rm

Outdoor Lighting 1 20 27 0.10 0.45 28 20 1 Recepts., Special Roj Rm

Dock Flood Lights 1 20 29 0.88 0.60 30 20 1 Recepts., Mech Rm, Mech

Spare 31 - 0.15 32 20 1 Recepts., Water Cooler

Spare 33 - 0.30 34 20 1 Recepts., IT Closet

Spare 35 - 0.45 36 20 1 Recepts., Break Room

37 1.30 0.45 38 20 1 Recepts., Break Room

Gib Cranes 3 40 39 1.30 0.75 40 20 1 Recepts., Office

41 1.30 0.75 42 20 1 Recepts., Office

43 0.10 0.45 44 20 1 Recepts., Gun Lab

ERW-1 3 15 45 0.10 46 20 1 Spare

47 0.10 - 48 20 1 Spare

49 2.33 - 50 20 1 Spare

AHU-1 3 60 51 2.33 - 52 20 1 Spare

53 2.33 - 54 20 1 Spare

55 0.47 - 56 20 1 Spare

EF-1 3 20 57 0.47 - 58 20 1 Spare

59 0.47 60 20 1 Spare

61 0.93 3.00 62

HWCP-1 3 30 63 0.93 3.00 64 35 3 Water Heater

65 0.93 3.00 66

67 0.93 - 68 Space Only

HWCP-2 3 30 69 0.93 - 70 Space Only

71 0.93 - 72 Space Only

73 0.47 - 74 Space Only

CHWP-1 & CHWP-2 33 30 75 0.47 - 76 Space Only

77 0.47 - 78 Space Only

29.40 -

Panel RP1 3 225 27.60 -

27.00 -

40.41 37.89 36.36 8.45 12.15 11.70

48.86 50.04 48.06 TOTALS, KW

FEEDER: TOP

X BOTTOM TOTAL CONN. LOAD 146,960 WATTS

FEED THRU LUGS TOTAL CONN. LOAD 408 AMPS

INTEG. EQUIP. RATING AMPS RMS SYM.

* Provide Handle Lock on Circuit Breaker

LOCATION: Gun Shop Mech Room 10,000

LP1

S O L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M

O D P

SPRINKLER SYSTEM GENERAL NOTES: APPLICABLE CODES AND STANDARDS

WATER SUPPLY DATA

SCOPE OF WORK

SPRINKLER SYSTEM GENERAL NOTES (CONT):

B U

IL

D

IN

G

F

IR

E P R O T E C T

IO

N G

E N E R A L N O T E S

F-001

FIRE PROTECTION LEGEND

GUN

WORKROOM

GUN LAB

GUN

VAULT

TOILETJANITOR

IT

CLOSET

LOADING DOCK

UP

S L O P E

5 6

A

D

1 2 3 4 7

B

C

UP

SLOPE

SEE CIVIL

PLANS

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M O D P

F-101

SCALE: 1/8" = 1'-0"

ROOF LEVEL SPRINKLER PLAN

B U

IL

D

IN

G

F

IR

E P R O T E C T

IO

N P L A N

F-101

SHEET NOTES

F-101

SCALE: 1/8" = 1'-0"

ROOM INTERIOR SPRINKLER PLAN

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M

O D P

ROD STIFFENER DETAIL

SCALE: NONE

PIPE STAND DETAIL

SCALE: NONE

RISER DETAIL

SCALE: NONE

RETURN BEND DETAIL

SCALE: NONE

UPRIGHT SPRINKLER DETAIL

SCALE: NONE

HANGER SPACING

SCALE: NONE

B U

IL

D

IN

G

F

IR

E P R O T E C T

IO

N D E T A

IL

F-501

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M

O D P

B U

IL

D

IN

G

F

IR

E P R O T E C T

IO

N D E T A

IL

S

F-502

CENTER LOAD HANGER DETAIL

SCALE: NONE

HANGER WITH RETAINING STRAP DETAIL

SCALE: NONE

LONGITUDINAL BRACING DETAIL

SCALE: NONE

4-WAY BRACING DETAIL

SCALE: NONE

LATITUDINAL BRACING DETAIL

SCALE: NONE

CONCRETE HANGER

SCALE: NONE

LATITUDINAL BRACING DETAIL

SCALE: NONE

4-WAY BRACING DETAIL

SCALE: NONE

LONGITUDINAL BRACING DETAIL

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M

O D P

IL

D

IN

G

F

IR

E P R O T E C T

IO

N D E T A

IL

S

F-503

BRANCH LINE RESTRAINT DETAIL

SCALE: NONE

BRANCH LINE RESTRAINT DETAIL

SCALE: NONE

BEAM CLAMP TRAPEZE HANGER

SCALE: NONE

CENTER LOAD TRAPEZE HANGER DETAIL

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M

O D P

FIRE ALARM GENERAL NOTES:

APPLICABLE CODES AND STANDARDS:

MASS NOTIFICATION SYSTEM NOTES:

B U

IL

D

IN

G

F

IR

E A L A R M G

E N E R A L N O T E S

FA-001

FIRE ALARM GENERAL NOTES (CONT):

P

FACP

MM

DACT

FIRE ALARM / MASS NOTIFICATION LEGEND

NAC

GUN LAB

GUN

VAULT

TOILETJANITOR

IT

CLOSET

LOADING DOCK

UP

S L O P E

5 6

A

D

1 2 3 4 7

B

C

UP

SLOPE

SEE CIVIL

PLANS

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M O D P

IL

D

IN

G

F

IR

E A L A R M P L A N

FA-101

FA-101

SCALE: 1/8" = 1'-0"

FIRST FLOOR PLAN

SHEET NOTES

FA-101

SCALE: 1/8" = 1'-0"

ROOM INTERIOR FLOOR PLAN

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M

O D P

DEVICE MOUNTING HEIGHTS

CONCEPTUAL RISER DIAGRAM

SCALE: NONE

B U

IL

D

IN

G

F

IR

E A L A R M D E T A

IL

S

FA-501

MANUAL PULL STATION

O P E R A

TI

O N

AUTOMATIC SPRINKLER FLOW SWITCH

AUTOMATIC SPRINKLER SYSTEM TAMPER SWITCH

A

LA

R M C O N D

IT

IO

N A T

FA

C P

S U P

ER

V

IS

O R Y C O N D

IT

IO

N A T

FA

C P

TR

O U B

LE

C O N D

IT

IO

N A T

FA

C P

TR

A N S M

IT

S

IG

N A L

TO

R E M O

TE

S

TA

TI

O N

FACP CIRCUIT FAULT (OPEN, GROUND, SHORT)

OTHER TROUBLE CONDITION

ACU MNS - HVAC GENERAL SHUTDOWN ACTIVATION

PRE-RECOREDED INPUT (WIDE AREA MNS INPUT) - ACT SIGNAL

ACU LIVE MESSAGE ACTIVATE

ACU PRE-RECORDED VOICE BUTTON SELECT

LIVE VOICE INPUT (WIDE AREA MNS INPUT)

ACU PRERECORDED "ALL CLEAR"

NON-EMERGENCY LIVE PAGING

S H U

TD

O W N A

LL

H

VA

C A H U S

R E S

ET

M N S S

TR

O B

ES

M N S S

TR

O B E S R E S E T S E C O N D S A

FT

E R M E S S A G E E N D

M N S S U P

ER

V

IS

O R Y F

IR

E A

LA

R M O V E R R

ID

E C O N D

IT

IO

N A T

FA

C U

GENERAL: CONTRACTORS RESPONSIBILITY TO ENSURE MNS AND FA PRIORITIES ARE PROGRAMMED IN ACCORDANCE WITH UFC 4-021-01

A C

TI

V

AT

E A U D

IO

C

IR

C U

IT

S

A C

TI

V

AT

E F

IR

E A

LA

R M S

TR

O

BE

S

A C

TI

V

AT

E M A S S N O

TI

FI

C

AT

IO

N S

TR

O B

ES

SEQUENCE OF OPERATIONS

SCALE: NONE

DUCT SMOKE DETECTOR ACTIVATION

S H U

TD

O W N A S S O C

IA

TE

D H V

AC

A H

GUN LAB

GUN

VAULT

TOILETJANITOR

IT

CLOSET

LOADING DOCK

UP

S L O P E

5 6

A

D

1 2 3 4 7

B

C

UP

SLOPE

SEE CIVIL

PLANS

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

A N S I D

/3 /0

H S B P C M O D P

G-101

SCALE: 1/8" = 1'-0"

FIRST FLOOR PLAN

B U

IL

D

IN

G

L

IF

E S A F E T Y P L A N

G-101

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M

O D P

M-001

XXX

B U

IL

D

IN

G

M E C H A N

IC

A L S Y M B O L S

F M A R A S

D .M

IR

A B

IL

E X

F M A R A S

F

IL

E N A M E M

B R O C K

/0 /2

UP

L O P E

5 6

A

D

1 2 3 4 7

B

C

UP

SLOPE

SEE CIVIL

PLANS

GUN

WORKROOM

GUN LAB

GUN

VAULT

MECH

ROOM

JANITOR

IT

CLOSET

LOADING DOCK

FLOOR PLAN

M-101

XXX

B U

IL

D

IN

G

M E C H A N

IC

A L F L O O R P L A N V E N T

IL

A T

IO

N

F M

C S

F M

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y Y

A N S I D

MEZZANINE PLAN

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M O D P

UP

L O P E

5 6

A

D

1 2 3 4 7

B

C

UP

SLOPE

SEE CIVIL

PLANS

GUN

WORKROOM

GUN

VAULT

IT

CLOSET

GUN

WORKROOM

GUN LAB

GUN

VAULT

MECH

ROOM

JANITOR

IT

CLOSET

LOADING DOCK

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M O D P

M-102

XXX

B U

IL

D

IN

G

M E C H A N

IC

A L F L O O R P L A N P

IP

IN

G

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y

YFLOOR PLAN

MEZZANINE PLAN

PUMP RACK DETAIL

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M

O D P

M-501

XXX

B U

IL

D

IN

G

M E C H A N

IC

A L D

E T A

IL

S

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y Y

TYPICAL AHU COIL PIPING DETAIL

ERW FILTER BANK DETAIL

1 FLEX DUCT TAKE-OFF DETAIL

150% DUCT TAKE-OFF DETAIL

IN-LINE PUMP DETAIL

DUCT LINER DETAIL

OUTSIDE AIR DUCT INSULATION DETAIL

HWS, HWR, CHWS & CHWR

SERVICE PIPING RISER

PUMP PERFORMANCE DATA

UNIT IMPELLER PUMP DISCH SUCTION PUMP MOTOR

MARK NO. SERVED LOCATION SIZE SIZE SIZE SIZE GPM FLUID FT./HD TYPE HP VOLTS/PH RPM MANUF/MODEL EFFICIENCY

HWCP-1 HW SYSTEM MEZZANINE 9.5 2x2x9-1/2B 2" 2" 72.5 35%PG 50 IN-LINE 3 208/3 1750 B&G/80 SERIES 75%

HWCP-2 HW SYSTEM MEZZANINE 9.5 2x2x9-1/2B 2" 2" 72.5 35%PG 50 IN-LINE 3 208/3 1750 B&G/80 SERIES 75%

CHWP-1 CHW SYSTEM MEZZANINE 5.125 2-1/2x2-1/2x7 2.5" 2.5" 42 35%PG 10.0 IN-LINE 3/4 208/3 1750 B&G/80 SERIES 75.60%

CHWP-2 CHW SYSTEM MEZZANINE 5.125 2-1/2x2-1/2x7 2.5" 2.5" 42 34%PG 10.0 IN-LINE 3/4 208/3 1750 B&G/80 SERIES 75.60%

EQUAL MANUFACTURES

TACO

ARMSTRONG

APPROVED EQUAL

GRILLES, REGISTERS AND DIFFUSERS PERFORMANCE DATA

MAX SP MAX

MARK NO. MOUNTING TYPE INS WC NC MATERIAL MAX. CFM MANUFACT./MODEL PATTERN NOM. FACE SIZE NOM. NECK SIZE FINISH ACCESSORIES

A LAY-IN S/A 0.02 20 ALUMINUM 100 PRICE/AMD 4-WAY 24x24 6x6/6∅ WHITE

B LAY-IN S/A 0.03 20 ALUMINUM 120 PRICE/AMD 4-WAY 24x24 9x9/7∅ WHITE

C DUCT MOUNTED S/A 0.065 20 ALUMINUM 300 PRICE/AMD 4-WAY 24x24 12x12/10∅ WHITE

D DUCT MOUNTED S/A 0.036 20 ALUMINUM 410 PRICE/AMD 4-WAY 24x24 15x15/10∅ WHITE

E DUCT MOUNTED S/A 0.036 20 ALUMINUM 700 PRICE/AMD 4-WAY 24x24 18x18/12∅ WHITE

F LAY-IN R/A-E/A 0.036 20 ALUMINUM 240 PRICE/PDR PERFORATED FACE 24x24 10x10 WHITE

G DUCT MOUNTED R/A 0.035 20 ALUMINUM 1640 PRICE/PDR PERFORATED FACE 24x24 22x22 WHITE

H DUCT MOUNTED R/A 0.035 20 ALUMINUM 1750 PRICE/PDR PERFORATED FACE 24x24 22x22 WHITE

J DUCT MOUNTED S/A 0.033 20 ALUMINUM 50 PRICE/AMD 4-WAY 24x24 6x6/6∅ WHITE

K DUCT MOUNTED S/A 0.04 20 ALUMINUM 120 PRICE/AMD 4-WAY 24x24 9x9/7∅ WHITE

EQUAL MANUFACTURERS:

CARNES METALAIRE

TITUS APPROVED EQUAL

KRUEGER

AIR HANDLING UNIT PERFORMANCE DATA

EXTERNAL

SP DROP MOTOR FILTER

MARK NO. LOCATION TYPE CFM MEDIA MBH GPM WPD ROWS EWT LWT LAT MEDIA MBH GPM WPD ROWS EWT LWT LAT INS WC HP VOLTS PH MANUF/MODEL #/THICKNESS/SIZE

AHU-1 MEZZANINE VERTICAL 6700 35% PG 195.74 42.0 7.1 8 45 55 57.85 35% PG 335.69 36.0 4.6 4 130 110 105.82 1.8 7.5 208 3 CARRIER/39MN14 (4)20x24 (2)20x20

ACCESSORIES: (INLCUDE FOR ALL AIR HANDLING UNITS) 3. ACCESS DOORS REQUIRED ON BOTH SIDES OF 6. ISOLATED MOTOR/FAN ASSEMBLY EQUAL MANUFACTURERS

1. ALL ACCESS DOORS TO BE HINGED & LATCHED FILTER BOX AND FAN SECTION 7. MAGNEHELIC GAUGE ACROSS FILTER BANK TRANE

2. FILTER/MIXING BOX W/ 4" MERV 8 THROW AWAY FILTERS 4. UNIT MOUNTED SMOKE DETECTORS MCQUAY

5. MOUNT ON 4" CONCRETE HOUSEKEEPING PAD. APPROVED EQUAL

COOLING COIL DATA HEATING COIL DATA

Max Min MBH EWT LWT GPM EAT LAT WPD APD Rows 2-way 3-way

VAV-1 109,108,107 PRICE SDV5000 6 190 190 12.3 130 110 1.5 55.0 89.97 0.31 0.36 3 X

VAV-2 110 PRICE SDV5000 6 240 240 10.7 130 110 1.0 55.0 92.93 0.24 0.25 3 X

VAV-3 101 PRICE SDV5000 24x16 3,500 3,500 134.8 130 110 14.0 55.0 88.58 18.67 0.58 3 X

VAV-4 104 PRICE SDV5000 14 1,320 1,320 56.0 130 110 5.5 55.0 91.86 3.88 0.34 3 X

VAV-5 102 PRICE SDV5000 14 1,640 1,640 52.4 130 110 5.5 55.0 93.32 3.40 0.28 3 X

TOTAL 6,890 6,890 266.1 27.5

EQUAL MANUFFACTURES

CARNES

TITUS

APPROVED EQUAL

AHU VARIABLE AIR VOLUME (VAV) BOX SCHEDULE

REMARKSSERVING (RM #) MANUFACTURER SIZEMARK

CFM CONTROL VA

MODEL

REHEAT COIL

ENERGY RECOVERY WHEEL SCHEDULE

(IN WG) (IN WG) OA/EA

MARK NO. SUPPLIES SCFM APD ECFM APD EFF. % HP VOLT PHASE HZ WEIGHT ACCESSORIES MANUFACTURER MODEL

ERW-1 AHU-1 96/2 78.6/57.3 3400 0.574 88.4/16.7 3400 0.574 112.5/204.8 79 1/4 208 3 60 525 1,2,3 GREENHECK ERM-58H-30

ACCESSORIES: EQUAL MANUFACTURER:

1. FILTER BANK 2" MERV 8 THROW AWAY FILTERS 1. COOK

2. ACCESS DOOR IN DUCTWORK CONNECTION WITH VISUAL PORT 2. CARNES

FOR FULL ACCESS TO WHEEL 3. APPROVED EQUAL

3. VARIABLE FREQUENCY DRIVE

OUTDOOR AIR

S/A INLET

TEMP �F T1

S/W

INDOOR AIR

S/A INLET

TEMP �F T2

S/W

L.A.T. E/A

TEMP �F T3 S/W

TOTAL

RECOVERED

S/W (MBH)

EXHAUST FAN PERFORMANCE DATA

SP DROP MOTOR LBS DAMPER

MARK NO. SERVICE TYPE CFM INS WC RPM HP VOLTS PH MANUF MODEL ACCESSORIES CONTROLS WT SIZE

EF-1 MEZZANINE INLINE CENTRIFUGAL 3500 1.25 1725 1.5 208 3 GREENHECK BSQ-240-15 1, 2, 3 1 415 35x35

EF-2 MEZZANINE INLINE CENTRIFUGAL 200 0.33 1725 .25 115 1 GREENHECK BSQ-80-4 1, 2, 3 3 79 12x12

ACCESSORIES: EQUAL MANUFACTURER: CONTROLS:

1. DISCONNECT SWITCH 1. COOK 1. BAS

2. VIBRATION ISOLATION HANGERS 2. CARNES 2. REVERSE ACTING THERMOSTAT

3. MOTOR OPERATED DAMPER AND ACTUATOR 3. APPROVED EQUAL 3. LIGHT SWITCH

M

CT

VFD

H L

MCTVFD

S

S

T

T

T

N.C.

N.C.

THCO2

TT

H L

T H L

M

CT

VFD

HWS

HWR

HWCHW

CHWS

CHWR

H L

MM

SF

HL

H L

RF

H L

S

S

S

S O L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M

O D P

MI501

XXX

B U

IL

D

IN

G

C O N T R O L S C H E M A T

IC

S

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y Y

AHU-1 & 2 TEMP CONTROL SCHEMATIC

TT

M

HWS HWR

M

HW

M

CT

N.C.

S

O

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M O D P

MI502

XXX

B U

IL

D

IN

G

C O N T R O L S C H E M A T

IC

S

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y Y

VAV TERMINAL TEMP. CONTROL SCHEMATIC

SCHEDULED EF TEMP. CONTROL SCHEMATIC

VARIABLE FREQUENCY DRIVE SCHEDULE

NEMA OUTPUT GPM, CFM, RPM

MARK NO. HP VOLTAGE PHASE ENCLOSURE AMPS RANGE

ERW-1 1/4 460 3 1 1.8 5 RPM - 30 RPM

ERW-2 7/15 120 1 1 3.6 5 RPM - 30 RPM

AHU-1 30-Jan 460 3 1 92.0 5000 CFM - 23900 CFM

AHU-2 2 460 3 1 7.8 400 CFM - 1330 CFM

RF-1 10 208 3 1 32.2 5000 CFM - 23900 CFM

PRE-1 2 208 3 1 7.8 400 CFM - 1330 CFM

HWCP-1 7.5 460 3 1 12.5 55 GPM - 219 GPM

HWCP-2 7.5 460 3 1 12.5 55 GPM - 219 GPM

NOTES: MANUFACTURERS:

1. STARTING TORQUE 0.5HZ TO 60 HZ YASKAWA

2. 110% RATED FLA 60 SEC. ABB

3. 180% RATED FLA INSTANTANEOUSLY HITACHI

4. RADIO FREQUENCY (RFI) ABOVE 7MHZ TOSHIBA

5. THD COMPLIANCE PER IEEE 519

6. MINIMUM SHORT CIRCUIT RATING OF 65K RMS

7. SEE SPECS FOR ADDITIONAL INFORMATION

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M O D P

MI504

XXX

B U

IL

D

IN

G

C O N T R O L S C H E M A T

IC

S

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y Y

B.A.S. ARCHITECTURAL SCHEMATIC

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M

O D P

MI601

XXX

B U

IL

D

IN

G

C O N T R O L S E Q U E N C E S O

F O

P E R A T

IO

N

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y

Hardware Points Software Points

Point Name AI AO BI BO AV BV Sched Trend Alarm Show On

Graphic

Supply Air Static Pressure × × × ×

Return Plenum Static Pressure

Outside Air Temp × × ×

Exhaust Air Temp × × ×

Heat Wheel Discharge Air Temp

Building Static Pressure × × ×

AHU Filter Delta P × ×

Heat Wheel EA Delta P × ×

Heat Wheel OA Delta P × ×

Mixed Air Temp × × ×

Return Air Carbon Dioxide

PPM

Return Air Humidity × × ×

Return Air Temp × × ×

Supply Air Temp × × ×

Supply Fan VFD Speed × × ×

Return Fan VFD Speed × × ×

Heat Wheel VFD Speed × × ×

Cooling Valve × × ×

Heating Valve × × ×

Exhaust Air Damper × ×

Freezestat × × × ×

High Static Shutdown × × × ×

Return Air Smoke Detector × × × ×

Supply Air Smoke Detector × × × ×

Supply Fan VFD Fault × × ×

Supply Fan Status × × ×

Return Fan Status × × ×

Return Fan VFD Fault × × ×

Heat Wheel Status × × ×

Heat Wheel VFD Fault × × × ×

Exhaust Air Damper Status × × ×

Supply Fan Start/Stop × × ×

Return Fan Start/Stop × × ×

Hardware Points Software Points

Point Name AI AO BI BO AV BV Sched Trend Alarm Show On

Graphic

Heat Wheel Start/Stop × × ×

Heat Wheel Bypass Dampers

Supply Air Static Pressure Setpoint

Return Plenum Static Pressure Setpoint

Supply Air Temp Setpoint × × ×

Building Static Pressure Setpoint

Dehumidification Setpoint × × ×

Schedule ×

High Supply Air Static Pressure

Low Supply Air Static Pressure

Supply Fan Failure ×

Supply Fan in Hand ×

Supply Fan Runtime Exceeded

High Return Plenum Static Pressure

Low Return Plenum Static Pressure

Return Fan Failure ×

Return Fan in Hand ×

Return Fan Runtime Exceeded

Heat Wheel Rotation Failure ×

Heat Wheel in Hand ×

Heat Wheel Runtime Exceeded

High Supply Air Temp ×

Low Supply Air Temp ×

Exhaust Air Damper Failure ×

Exhaust Air Damper in Hand ×

AHU Filter Change Required × ×

Heat Wheel EA Filter Change Required

Hardware Points Software Points

Point Name AI AO BI BO AV BV Sched Trend Alarm Show On Graphic

Heat Wheel OA Filter Change Required

High Mixed Air Temp ×

Low Mixed Air Temp ×

High Return Air Carbon Dioxide Concentration

High Return Air Humidity ×

Low Return Air Humidity ×

High Return Air Temp ×

Low Return Air Temp ×

High Supply Air Temp ×

Low Supply Air Temp ×

Outdoor Airflow × × ×

Exhaust Airflow × × ×

Outdoor Air Damper × ×

Mixing Box Dampers × ×

Outdoor Air Damper Status × × ×

L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M O D P

MI602

XXX

B U

IL

D

IN

G

C O N T R O L S E Q U E N C E S O F O P E R A T

IO

N

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y

Show On Graphic

Building Static Pressure × × ×

Fan VFD Speed × × ×

Fan VFD Fault × × ×

Exhaust Air Damper Status

Fan Status × × ×

Fan Start/Stop × × ×

Exhaust Air Damper × × ×

Building Static Pressure Setpoint

High Building Static Pressure

Low Building Static Pressure

Exhaust Air Damper Failure

Exhaust Air Damper in Hand

Fan Failure ×

Fan in Hand ×

Fan Runtime Exceeded ×

Show On

Graphic

Zone Temp × × ×

Zone Setpoint Adjust × ×

Airflow × × ×

Occupancy Sensing × × ×

Discharge Air Temp × × ×

Zone Damper × ×

Reheating Valve × × ×

Airflow Setpoint × × ×

Environmental Index × ×

Percent of Time Satisfied

Heating Mode × ×

Schedule ×

Heating Setpoint × ×

Cooling Setpoint × ×

High Zone Temp ×

Low Zone Temp ×

High Discharge Air Temp

Low Discharge Air Temp ×

L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M O D P

MI603

XXX

B U

IL

D

IN

G

C O N T R O L S E Q U E N C E S O F O P E R A T

IO

N

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y

Show On Graphic

Exhaust Air Damper Status

Fan Status × × ×

Fan Start/Stop × × ×

Exhaust Air Damper × × ×

Schedule ×

Exhaust Air Damper Failure

Exhaust Air Damper in Hand

Fan Failure ×

Fan in Hand ×

Fan Runtime Exceeded ×

Point Name AI AO BI BO AV BV Sched Trend Alarm Show On Graphic kW Pulse × ×

Current Demand Level × × kW Demand × × kW Peak Today × × kW Peak Month-to-Date × × kW Peak Year-to-Date × × kWh Today × ×

MWh Month-to-Date × ×

MWh Year-to-Date × ×

Meter Failure ×

Demand Level 1 ×

Demand Level 2 ×

Demand Level 3 ×

Gas Flow Rate ×

Demand × ×

Peak Today × ×

Peak Month-to-Date × ×

Peak Year-to-Date × ×

Usage Today × ×

Usage Month-to-Date × ×

Usage Year-to-Date × ×

Meter Failure ×

Show On

Graphic

Outside Air Temp × × ×

Outside Air Humidity × × ×

Outside Air Enthalpy × × ×

High Temp Today × ×

High Temp Month-to- Date

High Temp Year-to-Date × ×

Low Temp Today × ×

Low Temp Month-to- Date

Low Temp Year-to-Date × ×

Sensor Failure ×

Outside Carbon Dioxide × × ×

Water Flow Rate ×

Demand × ×

Peak Today × ×

Peak Month-to-Date × ×

Peak Year-to-Date × ×

Usage Today × ×

Usage Month-to-Date × ×

Usage Year-to-Date × ×

Meter Failure ×

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M

O D P

MI606

XXX

B U

IL

D

IN

G

C O N T R O L S E Q U E N C E S O

F O

P E R A T

IO

N

M B R O C K

M B R O C K

F M A R A S

X X X

F

IL

E N A M E X X X

M M /D D /Y Y

L

IC

IT

A T

IO

N N O

F

IL

E N

A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O

F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M

O D P

P-001

XXX

B U

IL

D

IN

G

P L U M B

IN

G L E G E N D

F M A R A S

M B R O C K

X X X

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y Y

A N S I D

GUN LAB

GUN

VAULT

TOILETJANITOR

IT

CLOSET

LOADING DOCK

UP

S L O P E

5 6

A

D

1 2 3 4 7

B

C

UP

SLOPE

SEE CIVIL

PLANS

P-101

XXX

B U

IL

D

IN

G

F

IR

S T F L O O R P L U M B

IN

G P L A N

F M

C S

F M

X X X

F

IL

E N A M E X X X

M M /D D /Y Y Y Y

FIRST FLOOR PIPING PLAN

PARTIAL FLOOR PLAN

PARTIALFOUNDATION PLAN

S O L

IC

IT

A T

IO

N N O

F

IL

E N A M E

D W N B Y

C K D B Y

D E S

IG

N E D B Y

D

2 3

C

4 5

A

B

US Army Corps of Engineers

D A T E

S

IZ

E

S U B M

IT

T E D B Y

P L O T D A T E

C O N T R A C T N O

SHEET OF XXX

P L O T T E D B Y

New York District

U S A R M Y E N G

IN

E E R D

IS

T R

IC

T

C O R P S O F E N G

IN

E E R S

N E W Y O R K N E W Y O R K

SHEET

REFERENCE NUMBER

G W S Y S T E M S T E C H D A T A F A C

IL

IT

Y

F Y B C A P /N

P

IC

A T

IN

N Y A R S E N A L N J

90% DESIGN SUBMITTALS - 06 / 30 / 2009

/3 /0

H S B P C M O D P

3350-ELECTRICAL-90
PN65527-3350-E001.pdf
PN65527-3350-E001.dwg
Sheet
PN65527-3350-E101.pdf
PN65527-3350-E101.dwg
Sheet
PN65527-3350-E102.pdf
PN65527-3350-E102.dwg
Sheet
PN65527-3350-E103.pdf
PN65527-3350-E103.dwg
Sheet

PN65527-3350-E601.pdf

Binder1
3350-GENERAL-90
PN65527-3350-G-000.pdf
PN65527-3350-G-001.pdf
PN65527-3350-C-100
PN65527-3350-CG-100
PN65527-3350-CG-101
PN65527-3350-CG-200
PN65527-3350-CG-201
PN65527-3350-CG-202
PN65527-3350-CS-100
PN65527-3350-CS-101
PN65527-3350-CS-102
PN65527-3350-CU-100
Binder2
3350-ARCHITECTURAL-90
PN65527-3350-A-101.pdf
PN65527-3350-A-102.pdf
PN65527-3350-A-201.pdf
PN65527-3350-A-202.pdf
PN65527-3350-A-301.pdf
PN65527-3350-A-401.pdf
PN65527-3350-A-402.pdf
PN65527-3350-A-403.pdf
PN65527-3350-A-405.pdf
PN65527-3350-A-501.pdf
PN65527-3350-A-502.pdf
PN65527-3350-A-601.pdf
PN65527-3350-A-602.pdf
3350-STRUCTURAL-90
PN-65527-3350-S-001 2234FB (1).pdf
PN-65527-3350-S-101 2234FB (1).pdf
PN-65527-3350-S-301 2234FB (1).pdf
PN-65527-3350-S-302 2234FB (1).pdf
PN-65527-3350-S-303 2234FB (1).pdf
PN-65527-3350-S-501 2234FB (1).pdf
PN-65527-3350-S-502 2234FB (1).pdf
PN-65527-3350-S-601 2234FB (1).pdf
Binder3
3350-FIRE PROTECTION-90
Bldg 3350 F001.dwg
F-001
Bldg 3350 F101.dwg
F-101
Bldg 3350 F501.dwg
F-501
F-502
F-503
Bldg 3350 FA001.dwg
FA-001
Bldg 3350 FA101.dwg
FA-101
Bldg 3350 FA501.dwg
FA-501
Bldg 3350 G101.dwg
G-101
3350-MECHANICAL-90
PN65527-3350-M-001.pdf
PN65527-3350-M-001.dwg
Sheet
PN65527-3350-M-101.pdf
PN65527-3350-M-101.dwg
Sheet
PN65527-3350-M102.pdf
PN65527-3350-M102.dwg
Sheet
PN65527-3350-M501.pdf
PN65527-3350-M501.dwg
SHEET
PN65527-3350-M601.pdf
PN65527-3350-MI501.pdf
PN65527-3350-MI501.dwg
SHEET
PN65527-3350-MI502.pdf
PN65527-3350-MI502.dwg
SHEET
PN65527-3350-MI504.pdf
PN65527-3350-MI504.dwg
SHEET
PN65527-3350-MI601.pdf
PN65527-3350-MI601.dwg
SHEET
PN65527-3350-MI602.pdf
PN65527-3350-MI602.dwg
SHEET
PN65527-3350-MI603.pdf
PN65527-3350-MI603.dwg
SHEET
PN65527-3350-MI606.pdf
PN65527-3350-MI606.dwg
SHEET
3350-PLUMBING-90
PN65527-3350-P-001XX.pdf
PN65527-3350-P-001XX.dwg
Sheet
PN65527-3350-P101.pdf
PN65527-3350-P101.DWG
Sheet

File details come from the government source that posted it. Updated .