E-101.pdf

PDF 125 KB Posted

Attached to
Fort Bragg SATOC
Solicitation number
W912DR-14-R-0025
Issued by

About this file

Dwg

View the file

Other files

File Type Posted
W912DR-14-R-0025-0003_Amendment_3_FINAL.pdf PDF
W912DR-14-R-0025-0002_Amendment_2.pdf PDF
W912DR-14-R-0025-0001_Amendment_1.pdf PDF
Contractor_Format_for_RFIs.xlsx XLSX spreadsheet
S-101.pdf PDF
A-401.pdf PDF
A-501.pdf PDF
A-301.pdf PDF
G-001.pdf PDF
A-402.pdf PDF
MP-001.pdf PDF
MP-101.pdf PDF
MP-601.pdf PDF
A-101.pdf PDF
Division_1_Fort_Bragg_SATOC_March_2014.pdf PDF
E-102.pdf PDF
E-001.pdf PDF
A-102.pdf PDF
C-102.pdf PDF
E-002.pdf PDF
C-101.pdf PDF
A-201.pdf PDF
A-001.pdf PDF
W912DR-14-R-0025_Fort_Bragg_SATOC_Solicitation.pdf PDF
MP-102.pdf PDF
MP-501.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A 120 87 3

BE 120 60 2

C1

C2

RECESSED

120 32 1

120 62 2

120 46 1

AE 120 87 3RECESSED

ALERA

AL Series

6' STAGGERED (1) LAMP, T8 LINEAR

FLUORESCENT PERIMETER WALL WASHER

COLUMBIA

4PS Series

COLUMBIA

HUBBELL OUTDOOR LIGHTING

LMC Series

32W T8

3500K - 80CRI

32W T8

3500K - 80CRI

32W T8

3500K - 80CRI

32W T8

3500K - 80CRI

42W TRIPLE CF

3500K - 82CRI

PROVIDE (1) T8 LAMP -

OVERLAP CONFIGURATION

FIXTURE SHALL BE

U.L. WET LOCATION LISTED

120 4 --

SL-1E

DUAL - LIGHT

LX Series

A1 RECESSED 120 64 2

B 120 60 2

COLUMBIA

4PS Series

2' x 4' LENSED TROFFER 32W T8

3500K - 80CRI

COLUMBIA

(2) LAMP, LINEAR FLUORESCENT

INDUSTRIAL FIXTURE

32W T8

3500K - 80CRI

PROVIDE WIREGUARD

COLUMBIA Model No.: CSRWG4

WALL/CEILING LEDX

COLUMBIA

4PS Series

CSR Series

CSR Series

ALERA

AL Series

(2) LAMP, LINEAR FLUORESCENT

INDUSTRIAL FIXTURE WITH INTEGRAL

EMERGENCY LIGHTING BATTERY PACK UNIT

FULL CUTOFF, (2) LAMP COMPACT

FLUORESCENT, ARCHTECTURAL WALLPACK

BATTERY PACK UNIT & INTEGRAL PHOTOCELL

WITH INTEGTRAL EMERGENCY LIGHTING SURFACE

SUSPENDED

FROM

STRUCTURE

SUSPENDED

FROM

STRUCTURE

RECESSED

RECESSED

32W T8

3500K - 80CRI

PROVIDE WIREGUARD

COLUMBIA Model No.: CSRWG4

8'-6" STAGGERED (1) LAMP, T8 LINEAR

FLUORESCENT PERIMETER WALL WASHER

(2) LAMP FLUORESCENT

AL-1T8P-RLD-EU-S-06.00-DL-BD

4PS24-332G-FSA12-3EU-F0835-BD

4PS24-232G-FSA12-EU-F0835-BD

4PS24-332G-FSA12-3EU-F0835-EL-BD

CSR4-332-U-EU-BD

CSR4-332-U-EU-EL-BD

AL-1T8P-RLD-EU-S-08.06-DL-BD

LMC-42F-8-1-PC120-BBU-120

LX-U-R-W-E-I

A1E RECESSED 120 64 2

COLUMBIA

4PS Series

2' x 4' LENSED TROFFER 32W T8

3500K - 80CRI

(2) LAMP FLUORESCENT WITH INTEGRAL

4PS24-232G-FSA12-EU-F0835-EL-BDEMERGENCY LIGHTING BATTERY PACK UNIT

UNIVERSAL MOUNT SINGLE/DOUBLE FACE

THERMOPLASTIC LED EXIT SIGN WITH

INTEGRAL NICKEL CADMIUM BATTERY,

WHITE HOUSING AND RED LETTERS.

2' x 4' LENSED TROFFER

(3) LAMP FLUORESCENT

2' x 4' (3) LAMP LENSED FLUORESCENT

TROFFER WITH INTEGRAL EMERGENCY

LIGHTING BATTERY PACK UNIT

TYPE

FIXTURE

FIXTURE DESCRIPTION & CATALOG NUMBER

MANUFACTURER

OR APPROVED EQUAL

F I X T U R E D A T A L A M P D A T A

WATTAGE

INPUT

VOLTAGEMOUNTING QTY. TYPE

R E M A R K S

Schedule Notes:

L U M I N A I R E S C H E D U L E

S2

S2

S2

S2

S1 S1

S1

S1

A 39 A 39 A 39

A 39A 39A 39A 39

A 39 A 39 A 39 A 39

A 39A 39 AE 39 AE 39

AE 41

A 39

AE 39

A1E 41

A 41

A1E 41

C2 41

C2 41

C1 41

C1 41A1 41

A1 41 A1 41

B 41

B 41

BE 41

BE 41

SL-1E

SL-1E

A - 39

A - 41

X

X a

2 3 a a a a a a a a a a a b b b b b

MULTI-PURPOSE

ROOM

STORAGE

ELEC ROOM

MECH ROOM

KITCHEN

FEMALE LATRINE

MALE LATRINE

JANITOR

Sb 3Sa

Sb

D

C

B

A

2 3 4 5

R e v

Sheet

Sheet reference number:

A p p r.

D a te

D e s c ri p ti o n

M a rk

D a te

D e s ig n f ile n o

D e s ig n e d b y

D w n b y

C k d b y

R e v ie w e d b y

S u b m itt e d b y

C h ie f, D ra w in g c o d e

F ile n a m e

P lo t s c a le

P lo t d a te of

B U

IL

D

IN

G

E

Baltimore District of Engineers US Army Corps

S U

B M

IS

S

IO

N

-2

-0

S

U B

M

IS

S

IO

N

-2

-0

/4

-3

-0

E -1

.d w g

-3

-0

J M

G

K D

B J M

G

K D

B

E L E

C T

R

IC

A L

L

IG

H T

IN

G

P L A

N

E-101 20 21

1/4" = 1'-0"E-101

ELECTRICAL LIGHTING PLAN1

KEYED NOTES:

OCCUPANCY SENSOR SWITCHES ALL MULTI-PURPOSE ROOM FIXTURES.

SUSPENDED LUMINAIRES IN THIS ROOM SHALL BE MOUNTED AT 9'-0" AFF

TO BOTTOM OF FIXTURE.

FIELD COORDINATE FINAL LOCATION OF LUMINAIRES IN THIS SPACE WITH

MECHANICAL EQUIPMENT, PIPING, AND DUCT WORK.

GENERAL NOTES:

PROVIDE ALL LINEAR FLUORESCENT LIGHT FIXTURES WITH QUICK DISCONNECT PER 2005 NEC 410.73.1.

EACH SINGLE PHASE CIRCUIT SHALL HAVE A SEPARATE NEUTRAL. SHARED NEUTRALS ARE NOT ALLOWED.2.

REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING PLAN AND EXACT LOCATION AND QUANTITIES OF LIGHTING FIXTURES. IDENTIFY

DISCREPENCAIES/CONFLICTS TO ARCHITECT FOR CLARIFICATION.

3.

REFER TO ARCHITECTURAL DOCUMENTATION FOR SWITCH AND SWITCH PLATE FINISH INFORMATION.4.

GANG ALL ADJACENT LIGHTING CONTROL SWITCHES HORIZONTALLY TOGETHER UNDER A SINGLE COVER PLATE. PROVIDE METAL BARRIERS

BETWEEN SWITCHES WHERE REQUIRED.

5.

ALL OCCUPANCY SENSOR DEVICES SHOWN ON PLAN DEPICT INTENT OF COVERAGE ONLY.PROVIDE OCCUPANCY SENSORS AND ANCILLARY POWER PACKS, DEVICES AND WIRING AS REQUIRED FOR A COMPLETE AND FULLY FUNCTIONING SYSTEM AND INSTALL PER MANUFACTURER'S

REQUIREMENTS TO MEET MAXIMUM COVERAGE WITH MINIMUM QUANTITY OF DEVICES.

6.

FIXTURE WITH INTEGRAL EMERGENCY LIGHTING BATTERY PACK UNIT INDICATED AS CONTROLLED BY LOCAL LIGHTING CONTROL DEVICE SHALL BE CONNECTED TO SWITCHED HOT AND UNSWITCHED HOT CONDUCTOR TAPPED AHEAD OF LOCAL SWITCHING TO ENSURE SENSE OF POWER LOSS AND THEREBY OPERATION OF THE EMERGENCY LIGHTING BATTERY PACK IN THE EVENT OF A POWER OUTAGE.

7.

EXIT SIGNAGE SHALL BE CONNECTED TO LOCAL LIGHTING CIRCUIT SERVING AREA OF ASSOCIATION AHEAD OF ANY SWITCHING.8.