E-101.pdf
PDF 125 KB Posted
- Attached to
- Fort Bragg SATOC
- Solicitation number
- W912DR-14-R-0025
About this file
Dwg
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912DR-14-R-0025-0003_Amendment_3_FINAL.pdf | ||
| W912DR-14-R-0025-0002_Amendment_2.pdf | ||
| W912DR-14-R-0025-0001_Amendment_1.pdf | ||
| Contractor_Format_for_RFIs.xlsx | XLSX spreadsheet | |
| S-101.pdf | ||
| A-401.pdf | ||
| A-501.pdf | ||
| A-301.pdf | ||
| G-001.pdf | ||
| A-402.pdf | ||
| MP-001.pdf | ||
| MP-101.pdf | ||
| MP-601.pdf | ||
| A-101.pdf | ||
| Division_1_Fort_Bragg_SATOC_March_2014.pdf | ||
| E-102.pdf | ||
| E-001.pdf | ||
| A-102.pdf | ||
| C-102.pdf | ||
| E-002.pdf | ||
| C-101.pdf | ||
| A-201.pdf | ||
| A-001.pdf | ||
| W912DR-14-R-0025_Fort_Bragg_SATOC_Solicitation.pdf | ||
| MP-102.pdf | ||
| MP-501.pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A 120 87 3
BE 120 60 2
C1
C2
RECESSED
120 32 1
120 62 2
120 46 1
AE 120 87 3RECESSED
ALERA
AL Series
6' STAGGERED (1) LAMP, T8 LINEAR
FLUORESCENT PERIMETER WALL WASHER
COLUMBIA
4PS Series
COLUMBIA
HUBBELL OUTDOOR LIGHTING
LMC Series
32W T8
3500K - 80CRI
32W T8
3500K - 80CRI
32W T8
3500K - 80CRI
32W T8
3500K - 80CRI
42W TRIPLE CF
3500K - 82CRI
PROVIDE (1) T8 LAMP -
OVERLAP CONFIGURATION
FIXTURE SHALL BE
U.L. WET LOCATION LISTED
120 4 --
SL-1E
DUAL - LIGHT
LX Series
A1 RECESSED 120 64 2
B 120 60 2
COLUMBIA
4PS Series
2' x 4' LENSED TROFFER 32W T8
3500K - 80CRI
COLUMBIA
(2) LAMP, LINEAR FLUORESCENT
INDUSTRIAL FIXTURE
32W T8
3500K - 80CRI
PROVIDE WIREGUARD
COLUMBIA Model No.: CSRWG4
WALL/CEILING LEDX
COLUMBIA
4PS Series
CSR Series
CSR Series
ALERA
AL Series
(2) LAMP, LINEAR FLUORESCENT
INDUSTRIAL FIXTURE WITH INTEGRAL
EMERGENCY LIGHTING BATTERY PACK UNIT
FULL CUTOFF, (2) LAMP COMPACT
FLUORESCENT, ARCHTECTURAL WALLPACK
BATTERY PACK UNIT & INTEGRAL PHOTOCELL
WITH INTEGTRAL EMERGENCY LIGHTING SURFACE
SUSPENDED
FROM
STRUCTURE
SUSPENDED
FROM
STRUCTURE
RECESSED
RECESSED
32W T8
3500K - 80CRI
PROVIDE WIREGUARD
COLUMBIA Model No.: CSRWG4
8'-6" STAGGERED (1) LAMP, T8 LINEAR
FLUORESCENT PERIMETER WALL WASHER
(2) LAMP FLUORESCENT
AL-1T8P-RLD-EU-S-06.00-DL-BD
4PS24-332G-FSA12-3EU-F0835-BD
4PS24-232G-FSA12-EU-F0835-BD
4PS24-332G-FSA12-3EU-F0835-EL-BD
CSR4-332-U-EU-BD
CSR4-332-U-EU-EL-BD
AL-1T8P-RLD-EU-S-08.06-DL-BD
LMC-42F-8-1-PC120-BBU-120
LX-U-R-W-E-I
A1E RECESSED 120 64 2
COLUMBIA
4PS Series
2' x 4' LENSED TROFFER 32W T8
3500K - 80CRI
(2) LAMP FLUORESCENT WITH INTEGRAL
4PS24-232G-FSA12-EU-F0835-EL-BDEMERGENCY LIGHTING BATTERY PACK UNIT
UNIVERSAL MOUNT SINGLE/DOUBLE FACE
THERMOPLASTIC LED EXIT SIGN WITH
INTEGRAL NICKEL CADMIUM BATTERY,
WHITE HOUSING AND RED LETTERS.
2' x 4' LENSED TROFFER
(3) LAMP FLUORESCENT
2' x 4' (3) LAMP LENSED FLUORESCENT
TROFFER WITH INTEGRAL EMERGENCY
LIGHTING BATTERY PACK UNIT
TYPE
FIXTURE
FIXTURE DESCRIPTION & CATALOG NUMBER
MANUFACTURER
OR APPROVED EQUAL
F I X T U R E D A T A L A M P D A T A
WATTAGE
INPUT
VOLTAGEMOUNTING QTY. TYPE
R E M A R K S
Schedule Notes:
L U M I N A I R E S C H E D U L E
S2
S2
S2
S2
S1 S1
S1
S1
A 39 A 39 A 39
A 39A 39A 39A 39
A 39 A 39 A 39 A 39
A 39A 39 AE 39 AE 39
AE 41
A 39
AE 39
A1E 41
A 41
A1E 41
C2 41
C2 41
C1 41
C1 41A1 41
A1 41 A1 41
B 41
B 41
BE 41
BE 41
SL-1E
SL-1E
A - 39
A - 41
X
X a
2 3 a a a a a a a a a a a b b b b b
MULTI-PURPOSE
ROOM
STORAGE
ELEC ROOM
MECH ROOM
KITCHEN
FEMALE LATRINE
MALE LATRINE
JANITOR
Sb 3Sa
Sb
D
C
B
A
2 3 4 5
R e v
Sheet
Sheet reference number:
A p p r.
D a te
D e s c ri p ti o n
M a rk
D a te
D e s ig n f ile n o
D e s ig n e d b y
D w n b y
C k d b y
R e v ie w e d b y
S u b m itt e d b y
C h ie f, D ra w in g c o d e
F ile n a m e
P lo t s c a le
P lo t d a te of
B U
IL
D
IN
G
E
Baltimore District of Engineers US Army Corps
S U
B M
IS
S
IO
N
-2
-0
S
U B
M
IS
S
IO
N
-2
-0
/4
-3
-0
E -1
.d w g
-3
-0
J M
G
K D
B J M
G
K D
B
E L E
C T
R
IC
A L
L
IG
H T
IN
G
P L A
N
E-101 20 21
1/4" = 1'-0"E-101
ELECTRICAL LIGHTING PLAN1
KEYED NOTES:
OCCUPANCY SENSOR SWITCHES ALL MULTI-PURPOSE ROOM FIXTURES.
SUSPENDED LUMINAIRES IN THIS ROOM SHALL BE MOUNTED AT 9'-0" AFF
TO BOTTOM OF FIXTURE.
FIELD COORDINATE FINAL LOCATION OF LUMINAIRES IN THIS SPACE WITH
MECHANICAL EQUIPMENT, PIPING, AND DUCT WORK.
GENERAL NOTES:
PROVIDE ALL LINEAR FLUORESCENT LIGHT FIXTURES WITH QUICK DISCONNECT PER 2005 NEC 410.73.1.
EACH SINGLE PHASE CIRCUIT SHALL HAVE A SEPARATE NEUTRAL. SHARED NEUTRALS ARE NOT ALLOWED.2.
REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING PLAN AND EXACT LOCATION AND QUANTITIES OF LIGHTING FIXTURES. IDENTIFY
DISCREPENCAIES/CONFLICTS TO ARCHITECT FOR CLARIFICATION.
3.
REFER TO ARCHITECTURAL DOCUMENTATION FOR SWITCH AND SWITCH PLATE FINISH INFORMATION.4.
GANG ALL ADJACENT LIGHTING CONTROL SWITCHES HORIZONTALLY TOGETHER UNDER A SINGLE COVER PLATE. PROVIDE METAL BARRIERS
BETWEEN SWITCHES WHERE REQUIRED.
5.
ALL OCCUPANCY SENSOR DEVICES SHOWN ON PLAN DEPICT INTENT OF COVERAGE ONLY.PROVIDE OCCUPANCY SENSORS AND ANCILLARY POWER PACKS, DEVICES AND WIRING AS REQUIRED FOR A COMPLETE AND FULLY FUNCTIONING SYSTEM AND INSTALL PER MANUFACTURER'S
REQUIREMENTS TO MEET MAXIMUM COVERAGE WITH MINIMUM QUANTITY OF DEVICES.
6.
FIXTURE WITH INTEGRAL EMERGENCY LIGHTING BATTERY PACK UNIT INDICATED AS CONTROLLED BY LOCAL LIGHTING CONTROL DEVICE SHALL BE CONNECTED TO SWITCHED HOT AND UNSWITCHED HOT CONDUCTOR TAPPED AHEAD OF LOCAL SWITCHING TO ENSURE SENSE OF POWER LOSS AND THEREBY OPERATION OF THE EMERGENCY LIGHTING BATTERY PACK IN THE EVENT OF A POWER OUTAGE.
7.
EXIT SIGNAGE SHALL BE CONNECTED TO LOCAL LIGHTING CIRCUIT SERVING AREA OF ASSOCIATION AHEAD OF ANY SWITCHING.8.
File details come from the government source that posted it. Updated .