A-001.pdf
PDF 95 KB Posted
- Attached to
- Fort Bragg SATOC
- Solicitation number
- W912DR-14-R-0025
About this file
Dwg
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W912DR-14-R-0025-0003_Amendment_3_FINAL.pdf | ||
| W912DR-14-R-0025-0002_Amendment_2.pdf | ||
| W912DR-14-R-0025-0001_Amendment_1.pdf | ||
| Contractor_Format_for_RFIs.xlsx | XLSX spreadsheet | |
| S-101.pdf | ||
| A-401.pdf | ||
| A-501.pdf | ||
| A-301.pdf | ||
| G-001.pdf | ||
| E-101.pdf | ||
| Division_1_Fort_Bragg_SATOC_March_2014.pdf | ||
| E-102.pdf | ||
| E-001.pdf | ||
| A-102.pdf | ||
| C-102.pdf | ||
| E-002.pdf | ||
| C-101.pdf | ||
| A-201.pdf | ||
| A-402.pdf | ||
| MP-001.pdf | ||
| MP-101.pdf | ||
| MP-601.pdf | ||
| A-101.pdf | ||
| W912DR-14-R-0025_Fort_Bragg_SATOC_Solicitation.pdf | ||
| MP-102.pdf | ||
| MP-501.pdf |
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R E
F
2006 INTERNATIONAL BUILDING CODE
CONSTRUCTION CLASSIFICATION: TYPE 5B
COMBUSTIBILITY (602):
EXTERIOR WALLS: COMBUSTIBLE
INTERIOR ELEMENTS: COMBUSTIBLE
ROOF: COMBUSTIBLE
FIRE RESISITIVE RATING FOR BUILDING ELEMENTS (TABLE 601):
FIRE RESISTANCE RATING OF STRUCTURAL FRAME: 0 HRS
FIRE RESISTANCE RATING OF EXTERIOR BEARING WALLS: 0 HRS
FIRE RESISTANCE RATING OF INTERIOR BEARING WALLS: 0 HRS
EXTERIOR NON-BEARING WALLS: 0 HRS
INTERIOR NON-BEARING WALLS (SEE DRAWING FOR TYPES AND LOCATIONS).
FIRE RESISTANCE RATINGS AND FIRE TESTS (703)
FIRE REISITANCE RATINGS (703.2): IN COMPLIANCE
NON COMBUSTIBILITY TEST (703.4): IN COMPLIANCE
EXTERNAL WALLS (704)
MATERIALS (704.4): IN COMPLIANCE
FIRE RESISTANCE RATINGS (704.5): IN COMPLIANCE
STRUCTURAL STABILITY (704.6): IN COMPLIANCE
MAXIMUM AREA OF EXTERIOR WALL OPENINGS (TABLE 704.8)UNPROTECTED GREATER THAN 30 FT
NO LIMIT
THERMAL AND SOUND INSULATING MATERIALS (719): IN COMPLIANCE
GENERAL MEANS OF EGRESS (1003):
CEILING HEIGHT (1003.2) 7 FT REQUIRED
9 FT AND 12 FT PROVIDED
EXITS (TABLE 1005.1)
DOORS:
36 INCHES / .15 WIDTH FACTOR = 240 PEOPLE
72 INCHES / .15 WIDTH FACTOR = 480 PEOPLE
NUMBER OF EXITS (TABLE 1018.1):
GROUND FLOOR: 134 PEOPLE 2 REQUIRED - 2 PROVIDED
MEANS OF EGRESS ILLUMINATION (1006): IN COMPLIANCE, SEE ELEC. DRAWINGS
MEANS OF EGRESS DOORS (1008): 32" MIN CLEAR WIDTH
DOOR LANDINGS (1008.1.5)
THRESHOLDS (1008.1.6): .5" MAX HEIGHT
DOOR OPERATIONS (1008.1.8)
HARDWARE HEIGHT (1008.1.8.2): 34" - 48" AFF
EXIT SIGNS (1011): IN COMPLIANCE, SEE ELEC. DRAWINGS
EXIT AND EXIT ACCESS DOORWAYS (1014): IN COMPLIANCE
EXIT ACCESS TRAVEL DISTANCE (1015, TABLE 1015.1) 300 FT MAX
CORRIDORS (1016)
CONSTRUCTION (1016.1) FIRE RESISTANCE RATING 0 HRS
WIDTH (1016.2) 44" MIN
DEAD END CORRIDORS (1016.3) 50 FT
AIR MOVEMENT IN CORRIDORS (1016.4) IN COMPLIANCE, SEE MECH. DRAWINGS
EXIT DISCHARGE (1023): IN COMPLIANCE
GYPSUM BOARD MATERIALS (2506):
GYPSUM BOARD MATERIALS & ACCESSORIES (TABLE 2506.2) IN COMPLIANCE
CHAPTER 33 - SAFEGUARDS DURING
CONSTRUCTION
THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL COMPLY WITH THE RULES AND
REGULATIONS SET FORTH IN THIS CHAPTER OF THE 2000 INTERNATIONAL BUILDING CODE.
OCCUPANT LOAD (1004.1.2, TABLE 1004.1.2):
DESIGN OCCUPANT LOAD: 134 PEOPLE
CODE REVIEW:
PROJECT NAME: Building E001
LOCATION: Fort Bragg, NC
ARCHITECTS:
APPLICABLE CODES: ICC INTERNATIONAL BUILDING CODE 2006
NFPA/ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES
ICC INTERNATIONAL FUEL GAS CODE
ICC INTERNATIONAL MECHANCIAL CODE
ICC INTERNATIONAL FIRE CODE
ICC INTERNATIONAL ENERGY CONSERVATION CODE
AREA OF WORK: 3000 SF
USE GROUP: B
CONSTRUCTION CLASS: 5B
AUTOMATIC SPRINKLER SYSTEM: NO
GENERAL NOTES
ALL WORK SHALL BE ACHIEVED PER INDUSTRY STANDARDS.
MANUFACTURER'S NAMEPLATES, INCLUDING TRADEMARK AND OTHER IDENTIFYING
SYMBOLS, SHALL NOT BE PERMITTED IN SURFACES VISIBLE TO THE PUBLIC, UNLESS
OTHERWISE INDICATED IN THE CONTRACT DOCUMENTS.
THE OWNER RESERVES THE RIGHT TO REJECT MATERIAL AND OR WORK THAT IS NOT IN
STRICT ACCORDANCE WITH THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL
PROTECT ADJACENT AREARS TO REMAIN IN OPERATION DURING THE CONSTRUCTION
PROJECT.
PROTECT AND REPAIR ALL AREAS AFFECTED BY THE CONSTRUCTION AS REQUIRED TO
MAINTAIN THEIR EXISTING APPEARANCE, UNLESS NOTED OTHERWISE.
REPAIR ALL SURFACES AND FINISHES TO MATCH EXISTING, AFTER DEMOLITION IS
COMPLETE. IF A PORTION OF AN EXISTING WALL TO REMAIN IS DEMOLISHED, THE
ENTIRE WALL OR CEILING SHALL BE PAINTED AFTER NEW CONSTRUCTION IS COMPLETED.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING THE STRUCTURAL
INTEGRITY OF THE BUILDING DURING DEMOLITION AND CONSTRUCTION. THE
CONTRACTOR SHALL BRACE ALL STRUCTURAL ELEMENTS DURING DEMOLITION AND
NEW CONSTRUCTION AS REQUIRED. THE CONTRACTOR SHALL INFORM THE ARCHITECT
OF ANY STRUCTURAL CONDITIONS UNCOVERED DURING THE DEMOLITION AND NEW
WORK WHICH ARE NOT ADDRESSED ON THE CONSTRUCTION DOCUMENTS.
ALL INTERIOR DIMENSIONS ARE FROM FACE OF FINISH TO THE FACE OF FINISH,
UNLESS OTHERWISE NOTED.
THE CONTRACTOR SHALL VERIFY THAT THERE ARE NO UTILITIES IN THE AREA OF
CONSTRUCTION BEFORE ANY WORK IS STARTED.
VERIFY ALL DIMENSIONS AT THE PROJECT SITE BEFORE STARTING CONSTRUCTION,
ORDERING OR FABRICATING ANY EQUIPMENT.
INSTALL ALL MANUFACTURED ITEMS IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS.
THE DRAWINGS ARE PREPARED AND COORDINATED WITH THE PROJECT MANUAL WHICH
INCLUDE TECHNICAL SPECIFICATIONS. THEY, ALONG WITH OTHER DOCUMENTS ISSUED
BY ARCH/ENGR AND ENUMERATED IN THE OWNER-CONTRACTOR AGREEMENT, SHALL
FORM THE CONSTRUCTION DOCUMENTS. A DIRECTIVE STATED IN ONE DOCUMENT SHALL
BE UNDERSTOOD AS STATED IN ALL. ANY AMBIGUITIES OR INCONSISTENCIES SHALL BE
RESOLVED BY ARCHITECT/ENGINEER.
DO NOT SCALE THE DRAWINGS. ANY DISCREPANCIES BETWEEN THE EXISTING
CONDITIONS AND THE CONTRACT DOCUMENTS, OR ANY AMBIGUITIES OR
INCONSISTENCIES CONTAINED THEREIN, SHALL BE REPORTED TO THE ARCHITECT AT
THE EARLIEST OPPORTUNITY, AND A SUITABLE RESOLUTION ESTABLISHED PRIOR TO
THE SUBMITTAL OF BIDS OR THE BEGINNING OF THE AFFECTED WORK. WORK THAT
PROCEEDS IN VIOLATION OF THIS PRINCIPLE IS AT THE CONTRACTOR'S OWN RISK, AND
THE COST OF ANY CHANGES REQUIRED BY CLIENT TO SUITABLY MODIFY
SUCH WORK SHALL BE SOLELY THE RESPONSIBILITY OF THE CONTRACTOR.
12.
11.
6.
5.
4.
9.
8.
7.
3.
2.
1.
10.
XX
XXXX
XX
XXXX
1st FLOOR
EL. XX'-0"
FLOOR ELEVATION TARGET
OR TOP OF MATERIAL
DESIGNATION
BUILDING DATUM ELEVATION
TITLE NAME
SCALE:
XX
XXXX
SECTION NUMBER
REFERENCE
SHEET NUMBER
DRAWING SYMBOLS
DETAIL NUMBER
REFERENCE
SHEET NUMBER
SECTION
INDICATOR
XX
XXXX
ELEVATION NUMBER
REFERENCE
SHEET NUMBER
ELEVATION
INDICATOR
XX
XXXX
DETAIL NUMBER
REFERENCE
SHEET NUMBER
DETAIL SECTION
INDICATOR
X
XXX
DETAIL
INDICATOR
INTERIOR ELEVATION
INDICATOR
DRAWING ELEVATION
IS SHOWN
ELEVATION NUMBER
NORTH
ARROW
XXXXDOOR TAG
XXWINDOW TAG
ROOM NAME
ROOM TAG
1KEYNOTE
DESIGNATION
ABBREVIATIONS
O
OC - ON CENTER
OD - OUTSIDE DIAMETER
OH - OVERHEAD
OPNG - OPENING
OPP - OPPOSITE
OPH - OPPOSITE HAND
OA - OVERALL
P
PANEL'G - PANELING
PR - PAIR
PSF - POUNDS PER SQUARE FOOT
PT - PAINT
PNL - PANEL
PL OR � - PLATE
PLAM - PLASTIC LAMINATE
PLYWD - PLYWOOD
PLBG - PLUMBING
PREFIN - PREFINISH
PRMLD - PREMOLDED
PTN - PARTITION
PART - PARTIAL
PLAS - PLASTER, PLASTIC
PTD - PAPER TOWEL DISPENSER
PTR - PAPER TOWEL RECEPTICLE
R
REINF - REINFORCED
REQ - REQUIRE
REQD - REQUIRED
RESIL - RESILIENT
RA GR - RETURN AIR GRILLE
REFL - REFLECT
RCP - REFLECTED CEILING PLAN
REPL - REPLACE
R - RISER/RADIUS
RB - RUBBER BASE
RND - ROUND
RM - ROOM
RO - ROUGH OPENING
S
SCHED - SCHEDULE
SHR - SHOWER
SGL - SINGLE
SC - SOLID CORE
SCWD - SOLID CORE WOOD DOOR
SND INS - SOUND INSULATION
SECT - SECTION
SHT - SHEET
SIM - SIMILAR
SPEC(S) - SPECIFICATIONS
SF - SQUARE FOOT(FEET)
SQ - SQUARE
SQ IN - SQUARE INCH
ST - STREET, STAIRS
STD - STANDARD
STL - STEEL
STR - STRUCTURAL
SST - STAINLESS STEEL
SUSP - SUSPEND, SUSPENDED
SUSP CLG - SUSPENDED CEILING
STOR - STORAGE
G
GALV - GALVANIZED
GLZ - GLAZING
GB - GRAB BAR
GA - GAUGE
GEN - GENERAL
GP - GLAZED PARTITION
GWB - GYPSUM WALL BOARD
GYP BD - GYPSUM BOARD
GOV'T - GOVERNMENT
H
HC - HANDICAP
HNDRL - HANDRAIL
HDW - HARDWARE
HDR - HEADER
HC - HOLLOW CORE
HCWD - HOLLOW CORE WOOD DOOR
HB - HOSE BIB
HGT - HEIGHT
HM - HOLLOW METAL
HORIZ - HORIZONTAL
HR - HOUR
H - HIGH
I
INSUL - INSULATION
INSTL - INSTALL
INT - INTERIOR
INV - INVERT
IBC - INTERNATIONAL BUILDING CODE
J
JAN - JANITOR
JAN CLO - JANITOR CLOSET
JS - JANITOR'S CLOSET
JT - JOINT
JST - JOIST
K
KIT - KITCHEN
L
LAM - LAMINATE
LRG - LARGE
LAV - LAVATORY
LT GA - LIGHT GAGE
LR - LIVING ROOM
LOC - LOCATION
M
MACH - MACHINE
MACH RM - MACHINE ROOM
MFR - MANUFACTURER
MAS - MASONRY
MRT - MARBLE THRESHOLD
MAX - MAXIMUM
MECH - MECHANICAL
MECH RM - MECHANICAL ROOM
MEZZ - MEZZANINE
MIN - MINIMUM
MO - MASONRY OPENING
MH - MOUNTING HEIGHT
MISC - MISCELLANEOUS
MTL - METAL
MT - METAL THRESHOLD
MOD - MODEL, MODIFY
N
N - NORTH
NA - NOT APPLICABLE
NIC - NOT IN CONTRACT
NO - NUMBER
NOM - NOMINAL
NL - NIGHT LIGHT
NTS - NOT TO SCALE
C CONTINUED
CSWK - CASEWORK
CT - CERAMIC TILE
CORR - CORRIDOR
CONST - CONSTRUCTION
CG - CORNER GUARD
COORD - COORDINATE
CTG - COATING
D
D - DEEP
DBL - DOUBLE
DH - DOUBLE HUNG (DOOR WINDOW)
DET - DETAIL
DEG - DEGREE
DEMO - DEMOLITION
DF - DRINKING FOUNTAIN
DIAG - DIAGONAL
DIM - DIMENSION
DR - DINING ROOM, DOOR, DRAIN
DUPL - DUPLICATE
DW - DISHWASHER
DIST - DISTANCE
DN - DOWN
DS - DOWN SPOUT
DWG - DRAWING
E
EA - EACH
EW - EACH WAY
EWC - ELECTRIC WATER COOLER
EL - ELEVATION
EJ - EXPANSION JOINT
ELEC - ELECTRICAL, ELECTRIC
EWH - ELECTRIC WATER HEATER
ENCL - ENCLOSURE
ENGR - ENGINEER
ELEV - ELEVATOR
ENVIR - ENVIRONMENT
EP - ELECTRICAL PANELBOARD
EQ - EQUAL
EQUIP - EQUIPMENT
ETC - ETCETERA, AND SO FORTH
EXH - EXHAUST
EXIST - EXISTING
EXP - EXPANSION, EXPAND
EXT - EXTERIOR
F
F - FEMALE
FIN FLR - FINISH FLOOR
FF EL - FINISH FLOOR ELEVATION
FNV - FEM. NAPKIN/TAMPON VENDOR
FWC - FABRIC WALLCOVERING
FTD - FACIAL TISSUE DISPENSER
FSTNR - FASTENER
FT - FEET
FE - FIRE EXTINGUISHER
FEC - FIRE EXTINGUISHER CABINET
FR - FIRE RATING, FRAME
FRMG - FRAMING
FIXT - FIXTURE
FLASH - FLASHING
FIN - FINISH
FRT - FIRE RETARDANT TREATED
FLR - FLOOR
FD - FLOOR DRAIN
FDTN - FOUNDATION
FURN - FURNITURE
FF&E - FURNITURE, FIXTURE & EQUIPMENT
FURG - FURRING
A
AB - ANCHOR BOLT
ABBRV - ABBREVIATION
AC - ACOUSTICAL
ACC - ACCESSIBLE
ACS PNL - ACCESS PANEL
ACT - ACOUSTICAL CEILING TILE
ACOUS INSUL - ACOUSTICAL INSULATION
ACU - AIR CONDITIONING UNIT
ADDM - ADDENDUM
AFF - ABOVE FINISH FLOOR
ADJ - ADJUSTABLE, ADJACENT
AHU - AIR HANDLING UNIT
ALUM - ALUMINUM
& - AND
@ - AT
A/C - AIR CONDITION
ARCH - ARCHITECT(URAL)
AWC - ACRYLIC WALL COVERING
ALT - ALTERNATE
ASWG - AMERICAN STEEL WIRE GUAGE
ADA - AMERICAN WITH DISABILITIES ACT
∠ - ANGLE
ANOD - ANODIZE
APPROX - APPROXIMATE
ASB - ASBESTOS
B
BM - BEAM
BMS - BEAMS
BR - BEDROOM
BRG - BEARING
BRG PL - BEARING PLATE
BLDG - BUILDING
BLW - BELOW
BKBD - BACKBOARD
BKD - BACKING
BTWN - BETWEEN
BS - BOTH SIDES
BW - BOTH WAYS
BOT - BOTTOM
BDRY - BOUNDRY
BLDG - BUILDING
BAT - BATTEN, BATTERY
BUR - BUILT UP ROOFING
C
CAB - CABINET
CB - CERAMIC BASE
CLG - CEILING
CLG HT - CEILING HEIGHT
CEM - CEMENT
CTR - CENTER
CLO - CLOSET
CL D - CLOTHES DRYER
CJ - CONSTRUCTION JOINT, CONTROL JOINT
CORR - CORRIDOR
CNTR - COUNTER
COV - COVER
CUST - CUSTODIAN
CER - CERAMIC
CT - CERAMIC TILE
CIR - CIRCLE
B LABEL - CLASS B DOOR
C LABEL - CLASS C DOOR
CL. - CENTER LINE℄
C TO C - CENTER TO CENTER
CLR - CLEAR
CMU - CONCRETE MASONRY UNIT
COL - COLUMN
CONC - CONCRETE
CONT - CONTINUOUS
COTR - CONTRACTING OFFICER'S TECHNICAL
REPRESENTATIVE
CPT - CARPET
CRS - COURSE
TOM - TOP OF MASONRY
TOS - TOP OF SLAB, TOP OF STEEL
TOW - TOP OF WALL
TB - TOWEL BAR
TD - TOWEL DESPENSER
TPD - TOILET PAPER DISPENSER
TPH - TOILET PAPER HOLDER
TWC - TEXTILE WALL COVERING
TYP - TYPICAL
U
UL - UNDERWRITERS LABORATORY
UON - UNLESS OTHERWISE NOTED
UNO - UNLESS NOTED OTHERWISE
V
VAR - VARIES
VR - VAPOR RETARDER
VB - VINYL BASE
VEST - VESTIBULE
VERT - VERTICAL
VIF - VERIFY IN FIELD
VCT - VINYL COMPOSITION TILE
VWC - VINYL WALL COVERING
W
WWF - WELDED WIRE FABRIC
W - WIDE
WB - WOOD BASE
WC - WALL COVERING, WATER CLOSET
WF - WIDE FLANGE
W/ - WITH
W/O - WITHOUT
WR - WATER RESISTANT
WD - WOOD, WOOD DOOR
WP - WORK POINT, WATER PUMP
T
T - TREAD
TEL - TELEPHONE
THRESD - THRESHOLD
TC - TOP OF CURB
TEMP - TEMPORARY
TOB - TOP OF BEAM
TOC - TOP OF CONCRETE
TOF - TOP OF FLOOR
D
C
B
A
2 3 4 5
R e v
Sheet
Sheet reference number:
A p p r.
D a te
D e s c ri p ti o n
M a rk
D a te
D e s ig n f ile n o
D e s ig n e d b y
D w n b y
C k d b y
R e v ie w e d b y
S u b m itt e d b y
C h ie f, D ra w in g c o d e
F ile n a m e
P lo t s c a le
P lo t d a te of
B U
IL
D
IN
G
E
Baltimore District of Engineers US Army Corps
S U
B M
IS
S
IO
N
-2
-0
S
U B
M
IS
S
IO
N
-2
-0
A s i n d ic a te d
-3
-0
-3
-0
H K
D
J W
S H
K D
A B
C O
D E
D A
T A
A B
B R
E V
IA
T
IO
N
S
L E
G E
N D
A N
D L
IF
E
S A
F E
T Y
P L A
N
A-001 4 21
1/16" = 1'-0"A-201
LIFE SAFETY PLAN4
File details come from the government source that posted it. Updated .