A-501.pdf

PDF 58 KB Posted

Attached to
Fort Bragg SATOC
Solicitation number
W912DR-14-R-0025
Issued by

About this file

Dwg

View the file

Other files

File Type Posted
W912DR-14-R-0025-0003_Amendment_3_FINAL.pdf PDF
W912DR-14-R-0025-0002_Amendment_2.pdf PDF
W912DR-14-R-0025-0001_Amendment_1.pdf PDF
Contractor_Format_for_RFIs.xlsx XLSX spreadsheet
S-101.pdf PDF
A-401.pdf PDF
A-301.pdf PDF
G-001.pdf PDF
A-001.pdf PDF
W912DR-14-R-0025_Fort_Bragg_SATOC_Solicitation.pdf PDF
MP-102.pdf PDF
MP-501.pdf PDF
E-101.pdf PDF
Division_1_Fort_Bragg_SATOC_March_2014.pdf PDF
E-102.pdf PDF
E-001.pdf PDF
A-102.pdf PDF
C-102.pdf PDF
E-002.pdf PDF
C-101.pdf PDF
A-201.pdf PDF
A-402.pdf PDF
MP-001.pdf PDF
MP-101.pdf PDF
MP-601.pdf PDF
A-101.pdf PDF
Show all 26

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DIVISION 06 - WOOD, PLASTICS, AND COMPOSITES

SECTION 06 20 00 - FINI5H CARPENTRY

1.01 MATERIALS AND WORKMANSHIP OF ALL MILLWORK SHALL CONFORM TO THE CUSTOM

GRADE REQUIREMENTS OF THE ARCHITECTURAL WOODWORKING INSTITUTE QUALITY

STANDARDS, LATEST EDITION, UNLESS OTHERWISE INDICATED.

1.02 CORE MATERIAL FOR SHELVING: EXTERIOR GRADE, DFPA, DOUGLAS FIR PLYWOOD

PANELS WITH TYPE "A" FACE AND TYPE "B" BACK VENEERS.

1.03 CORE MATERIAL FOR CABINETRY: PARTICLE BOARD, 3-PLY 45 IBS. PER CUBIC FOOT

DENSITY MATERIAL.

1.04 COUNTER TOPS AND BACKSPLASH CONTAINING SINKS SHALL BE DOUGLAS FIR EXTERIOR

GRADE VENEER CORE WITH "A" FACE AND "B" BACK.

A. VERTICAL GRADE VGP (0.028 INCH NOMINAL THICKNESS) SHALL BE APPLIED TO ALL

CABINET DOOR AND DRAWER FRONTS AND EXPOSED BACK AND END PANELS.

B. CABINET LINER CLS (0.020 INCH NOMINAL THICKNESS) SHALL BE USED ON ALL CASEWORK

INTERIORS NORMALLY EXPOSED TO VIEW WHEN CABINETS ARE OPEN.

D. EDGE BANDING SHALL BE SELF-EDGE APPLIED BEFORE FACES.

E. PLASTIC LAMINATE SHALL BE AS MANUFACTURED BY FORMICA, SIMILAR MATERIALS BY

NEVAMAR, OR WILSONART OR APPROVED EQUAL.

1.07 HARDWARE UNLESS SPECIFIED OR CALLED OUT ON THE DRAWINGS SHALL BE CABINET

MANUFACTURER'S STANDARD INSTITUTIONAL GRADE COMPONENTS SUBJECT TO APPROVAL OF

THE CONTRACTING OFFICER.

A. HINGES SHALL BE FRAMELESS CONCEALED TYPE ANSI B01602 FOR OVERLAY DOORS.

B. DOOR AND DRAWER PULLS SHALL BE WIRE TYPE EQUAL TO STANLEY MODEL 4484

(US28).

C. DRAWER GUIDES (100 IBS. CAPACITY), ANSI B05051.

D. ADJUSTABLE SHELF STANDARDS MORTISE MOUNTED, ANSI B04071. OPEN SHELF REST

B04091.

E. ANY OTHER TYPES REQUIRED FOR A COMPLETE ASSEMBLY.

1.08 SOLID SURFACING MATERIAL: COUNTERTOPS, BACKSPLASES, APRONS AND OTHER

COMPONENTS, WHERE INDICATED, AS MANUFACTURER BYCORIAN AS MANUFACTURED BY

DUPONT OR APPROVED EQUAL.

1.09 ALL MILLWORK SHALL BE INSTALLED PLUMB AND TRUE TO LINE AND LEVEL.

1.10 SUBMIT SAMPLES OF SOLID SURFACING MATERIAL FOR FINISH AND COLOR.

1.11 PIOR TO FABRICATION IT SHALL BE THE MILLWORK CONTRACTOR'S RESPONSIBILITY

TO VISIT THE SITE AND TAKE FIELD MEASUREMENTS TO VERIFY MILLWORK LOCATIONS AND

DIMENSIONS.

DIVISION 07 - THERMAL AND MOISTURE PROTECTION

SEDTION 07 41 63 - METAL STANDING SEAM ROOF

1.01 THE ROOFING SYSTEM IS DEFINED AS THE ASSEMBLY OF ROOFING COMPONENTS,

INCLUDING ROOFING PANEL, FLASHING, FASTENERS, AND ACCESSORIES WHICH, WHEN

ASSEMBLED PROPERLY RESULT IN A WATERTIGHT INSTALLATION.

1.02 ROOFING PANELS MATERIAL: 3004 ALUMINUM, ASTM B 209., MINIMUM THICKNESS: .040

INCH.

1.03 FINISH : ALCAD FLUOROCARBON BAKED ENAMEL EXTERIOR AND HAVE SMOOTH

TEXTURE.

1.04 PANEL SHALL BE 16" WIDE WITH A MINUM 2" HIGH VERTICAL LEGS AND TWO 0.37 INCH

STIFFENING RIBS AT 4 " ON CENTER.

1.05 ATTACHMENT CLIPS SHALL BE NON-MAGNETIC STAINLESS STEEL.

1.06 INSTALL IN ACCORDANCE WITH APPROVED MANUFACTURER'S ERECTION

INSTRUCTIONS .

SECTION 07 84 00 - FIRESTOPPING

1.01 PROVIDE FIRESTOPPING COMPOSED OF COMPONENTS THAT ARE COMPATIBLE WITH

EACH OTHER, THE SUBSTRATES FORMING OPENINGS, AND THE ITEMS, IF ANY, PENETRATING

THE FIRESTOPPING UNDER CONDITIONS OF SERVICE AND APPLICATION, AS DEMONSTRATED

BY FIRESTOPPING MANUFACTURER BASED ON TESTING AND FIELD EXPERIENCE.

1.02 PROVIDE FIRESTOPPING SYSTEMS THAT ARE PRODUCED AND INSTALLED TO RESIST THE

SPREAD OF FIRE AND THE PASSAGE OF SMOKE AND OTHER GASES THROUGH GYPSUM

DRYWALL AND CONCRETE MASONRY UNIT WALLS, ACCORDING TO FOLLOWING SYSTEMS

REQUIREMENTS AND 1 HOUR AND 2 HOUR RATINGS INDICATED.

A. F-RATED THROUGH-PENETRATION FIRESTOP SYSTEMS: PROVIDE THROUGH-PENETRATION

FIRESTOP SYSTEMS WITH F RATINGS, AS DETERMINED PER ASTM E 814, BUT NOT LESS THAN

THAT EQUALING OR EXCEEDING THE FIRE RESISTANCE RATING OF THE CONSTRUCTION

PENETRATED.

1. WHERE FIRESTOP SYSTEMS PROTECT PENETRATING ITEMS LARGER THAN A 4-INCH

DIAMETER NOMINAL PIPE OR 16 SQ. IN. IN OVERALL CROSS-SECTIONAL AREA.

C. FIRE RESISTIVE JOINT SEALANTS: PROVIDE JOINT SEALANTS WITH FIRE-RESISTANT

RATINGS INDICATED, AS DETERMINED PER ASTM E 119, BUT NOT LESS THAN THAT EXCEEDING

THE FIRE-RESISTANCE RATING OR THE CONSTRUCTION IN WHICH THE JOINT

OCCURS.

1.03 FIRESTOPPING MATERIALS MANUFACTURERS SHALL BE EQUAL TO HILTI CONSTRUCTION

CHEMICALS, INC., NELSON FIRESTOP PRODUCTS, OR 3M FIRE PROTECTION PRODUCTS.

SECTION 07 92 00 - JOINT SEALANTS

1.01 INTERIOR CAULKING, UNLESS OTHERWISE INDICATED, SHALL BE ACRYLIC LATEX CAULK

COMPLYING WITH ASTM C834, TYPE P, GRADE NF, AS MANUFACTURED BY BOSTIK, PECORA,

SONNEBORN, TREMCO OR APPROVED EQUAL.

1.02 SINGLE COMPONENT MILDEW RESISTANT SILICONE SEALANT, COMPLYING WITH ASTM

C920, TYPE S, GRADE NS, CLASS 25, USES NT, G, AND A, EQUAL TO PRODUCT MANUFACTURED

BY GENERAL ELECTRIC, DOW CORNING, PERCORA OR TREMCO AND SHALL BE USED AT

MILLWORK ITEMS AND IN TOILET ROOMS.

1.03 BACKER RODS SHALL BE EXTRUDED CLOSED CELL POLYETHYLENE FOAM OR OPEN CELL

POLYURETHANE FOAM SUBJECT TO APPROVAL OF THE SEALANT MANUFACTURER.

DIVISION 08 - OPENINGS

SECTION 08 II 00 - STEEL DOORS AND FRAMES

1.01 HOLLOW METAL FRAMES SHALL COMPLY WITH ANSI/SDI A250.8 AND BE FABRICATED OF

WELDED 16 GAUGE COLD ROLLED STEEL COMPLYING WITH ASTM A 1008 AND FORMED AS

DETAILED.

1.02 SHOP FINISH FOR ALL DOORS AND FRAMES SHALL BE ONE (I) COAT BAKED-ON PRIMER,

BAKED ON AT 300 DEGREES F.

1.03 DOORS AND FRAMES SHALL BE REINFORCED, DRILLED, TAPPED AND CUT-OUT AS REQUIRED

FOR HARDWARE. PROVIDE MORTAR SHIELDS BEHIND ALL CUT-OUTS IN FRAMES INSTALLED IN

MASONRY WALLS.

1.04 ALL FRAME CORNERS SHALL BE MITERED, JOINTS FLUSH, WELDED ON CONCEALED FACES, GROUND AND POLISHED SMOOTH.

1.05 RUBBER SILENCING BUTTONS SHALL BE FURNISHED AND INSTALLED IN ALL DOOR STOPS.

1.06 PROVIDE TEMPORARY SPREADERS AT FEET OF ALL DOOR FRAMES.

1.07 FIRE RATED DOORS AND FRAMES SHALL BEAR THE UNDERWRITER'S LABORATORY (UL) LABEL

FOR THE DESIGNATED RATING.

1.08 SUBMIT MANUFACTURER IS TECHNICAL PRODUCT DATA AND SHOP DRAWINGS.

SECTION 08 14 00 - FLUSH WOOD DOORS

1.01 DOORS SHALL BE SOLID CORE FLUSH DOORS, 5-PLY STAVE CORE AS MANUFACTURED BY

ALGOMA HARDWOODS, INC., EGGERS INDUSTRIES, OR MARSHFIELD DOOR SYSTEMS, INC. DOORS

SHALL COMPLY WITH WDMA I.S. I-A AND AWI SECTION 1300 SLC-5.

1.02 DOORS SHALL BE GUARANTEED FOR LIFE OF INSTALLATION.

1.03 FIRE RATED DOORS SHALL BEAR THE UNDERWRITER'S LABORATORY (U.L.) LABEL FOR THE

DESIGNATED RATING.

1.04 SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA. SUBMIT FINISH SAMPLES FOR COLOR

AND FINISH SELECTION.

SECTION 08710 - DOOR HARDWARE

1.01 SUBMIT MANUFACTURER'S TECHNICAL DATA FOR EACH ITEM, HARDWARE SCHEDULE AND

TEMPLATES AT EARLIEST POSSIBLE DATE.

1.02 CYLINDER CORES FURNISHED AND INSTALLED BY GOVERNMENT.

I.O3 EACH TYPE OF HARDWARE SHALL BE BY A SINGLE MANUFACTURER.

1.04 FINISH: SATIN STAINLESS STEEL ANSI/BHMA 630/US32D. PROVIDE BRIGHT ANSI/BHMA 605/US3

BRASS FINISH AT ROOM 117 AND II7A

1.05 ACCEPTABLE MANUFACTURERS OR APPROVED EQUAL:

A. BUTTS: HAGER, MCKINNEY OR STANLEY.

B. PIVOTS: DORMA ARCHITECTURAL HARDWARE, IVES OR RIXSON.

C. LOCKS AND LATCHES: MATCH MANUFACTURER OF EXISTING ADJACENT UNITS; MUST

ACCEPT GOVERNMENT SUPPLIED CYLINDERS.

D. EXIT DEVICES: PRECISION, SARGENT OR VON DUPRIN.

E. CLOSERS: DORMA ARCHITECTURAL HARDWARE, LCN OR NORTON.

F. DOOR TRIM UNITS: HAGER, IVES OR ROCKWOOD.

G. AUXILIARY HARDWARE: HAGER, IVES OR ROCKWOOD.

1.06 SCHEDULE IS BASED ON ANSI AI56 SERIES SPECIFICATIONS. WERE A PARTICULAR

MANUFACTURER IS LISTED; ANY MANUFACTURER FROM ABOVE LIST WITH EQUAL DEVICES MAY BE

SUBSTITUTED AS APPROVED BY THE OWNER.

1.01 HARDWARE SCHEDULE:

Group 1 Door Nos. 101A and 101B

Each to Have:

3 Hinges A5112 - 4.5 x 4.5 1 Outside Key Lock cylinder and core 1 Closer C72021

1 Set Wheatherstripping

Group 3 Door Nos. 102 and 103 Each to Have:

3 Hinges A8112 - 4.5 x 4.5 x safety stud 1 Lockset F07, Grade 1 1 Cylinder & core 1 Floor Stop L12141 3 Silencers L03011

Group 2 Door No. 104 Pair of Doors to Have:

6 Hinges A8112 - 4.5 x 4.5 x safety stud 1 Latchset F07, Grade 1 1 Cylinder and Core 3 Closer C72011

1 Exit Device Series 99 Rim Device, 1 Set Manual Flush Bolts on inactive leaf 1 Astragal Seal

3 Silencers L03011 1 Metal Threshold

Group 5 Door Nos. 107 and 108 Each to Have:

3 Hinges A8112 - 4.5 x 4.5 x safety stud 1 Push Plate- J301 1 Pull Plate- J405

Floor Stop L121411 Closer C72021

Group 4 Door No. 109

3 Hinges A8112 - 4.5 x 4.5 x safety stud 1 Lockset F07, Grade 1 1 Cylinder & core 1 Closer C72021 with delay-action 1 Kick plate JI02 - 8"x 34" LDW x B4E x CSK

Group 6 Door No. 106

2 sets Center pivots C17032 1 Deadlock E0151 (Locate below push plates) 2 Push plates J304 - 4" x 16" x B4E x CSK 2 Kick plates J102 - 8" x 34" LDW x B4E x CSK 1 Concealed closer C75061

3 Silencers L03011

DIVISION 09 - FINISHES

SECTION 09 29 00 - GYPSUM BOARD

1.01 MATERIALS SHALL BE STANDARD COMMERCIAL PRODUCTS AS MANUFACTURED BY U.S.

GYPSUM COMPANY, NATIONAL GYPSUM COMPANY, BPB AMERICA INC., OR LAFARGE NORTH

AMERICA INC. UNLESS OTHERWISE SPECIFIED. ALL SHALL CONFORM TO APPLICABLE

REQUIREMENTS OF THE ASTM STANDARD.

1.02 GYPSUM WALLBOARD SHALL BE 5/8" THICK, TAPERED EDGE, TYPE X FIRECODE UNLESS

OTHERWISE INDICATED, MEETING ASTM C36.

1.03 WATER RESISTANT GYPSUM WALLBOARD SHALL BE 5/8 INCH THICK, UNLESS OTHERWISE

INDICATED, MEETING ASTM C 630.

1.04 CEMENTITIOUS BOARD COMPLYING WITH ASTM A118.9, OF THICKNESS AND WIDTH INDICATED BELOW, AND IN MAXIMUM LENGTHS AVAILABLE TO MINIMIZE END-TO-END BUTT JOINTS. MATERIAL

SHALL BE DUROCK CEMENT BOARD AS MANUFACTURED BY UNITED STATES GYPSUM CO., OR

EQUAL.

A THICKNESS: 5/8 INCH, UNLESS OTHERWISE INDICATED.

B. WIDTH: MANUFACTURER'S STANDARD WIDTH, BUT NOT LESS THAN 32 INCHES.

1.05 STEEL STUDS AND RUNNERS SHALL BE 20 GAUGE GALVANIZED STEEL SPACED 16" O.C.,

UNLESS INDICATED OTHERWISE. MANUFACTURERS SHALL BE EQUAL TO DIETRICH METAL FRAMING, MARINO/WARE (FORMERLY MARINO INDUSTRIES CORP), NATIONAL GYPSUM CO., UNIMAST, INC.

1.06 PROVIDE GALVANIZED STEEL CORNER AND EDGE BEADS AS JOB CONDITIONS REQUIRE.

1.08 CARRYING CHANNELS SHALL BE HOT OR COLD ROLLED 16 GAUGE STEEL WITH RUST

INHIBITIVE PAINT FINISH.

1.09 HANGER WIRE SHALL BE ASTM A 641, SOFT, NO. 12 GAUGE MINIMUM CLASS I GALVANIZED.

1.10 JOINT TREATMENT FOR GYPSUM BOARD SHALL BE ALL-PURPOSE READY-MIXED COMPOUND

AND CROSS-FIBERED PAPER REINFORCED TAPE.

1.11 SCREW HEADS, JOINTS, AND OTHER DEPRESSIONS IN THE SURFACE OF THE GYPSUM

BOARD SHALL BE TREATED WITH JOINT COMPOUND AND TAPE AS RECOMMENDED BY THE

MANUFACTURER. SAND AND FINISH SMOOTH AND COMPLETE READY TO RECEIVE FINISH.

1.12 PROVIDE 18 GAUGE BLACK SHEET STEEL BEHIND GYPSUM BOARD ON FACE OF STUDS, AS

REQUIRED TO SUPPORT WALL MOUNTED EQUIPMENT, HARDWARE, OR ACCESSORIES INDICATED

ON DRAWINGS.

1.13 GYPSUM BOARD SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE

MANUFACTURER'S RECOMMENDATIONS.

1.15 WERE INDICATED, PARTITIONS SHALL BE INSULATED WITH ACOUSTICAL INSULATION.

INSULATION SHALL BE UNFACED MINERAL FIBER BLANKET INSULATION PRODUCED COMBINING

MINERAL FIBERS MANUFACTURED FROM GLASS WITH THERMOSETTING RESINS TO COMPLY WITH

ASTM C665 FOR TYPE I BLANKETS.

SECTION 09 30 00 - CERAMIC TILE

1.01 CERAMIC. TILE:

A. FLOOR TILE SHALL BE AS MANUFACTURED BY CROSSVILLE OR APPROVED EQUAL.

B. WALL TILE SHALL BE AS MANUFACTURED BY AMERICAN OLEAN TILE COMPANY OR APPROVED

EQUAL.

C. PROVIDE TRIM UNITS TO MATCH FIELD TILE. PROVIDE BULLNOSE TRIM.

D. BASE SHALL BE COVE AND SHALL MATCH FLOOR TILE.

1.03 THRESHOLD SHALL BE WHITE, HONED MARBLE COMPLYING WITH MIA GROUP "A"

REQUIREMENTS FOR SOUNDNESS. THRESHOLDS SHALL ALSO COMPLY WITH THE ACCESSIBILITY

GUIDELINES OF THE AMERICANS WITH DISABILITIES ACT AND STATE AND LOCAL ACCESSIBILITY

CODES.

1.04 SETTING MATERIAL:

A. CERAMIC FLOOR TILE: LATEX PORTLAND CEMENT MORTAR COMPLYING WITH ANSI A118.4.

1.05 GROUT MATERIAL:

A. CERAMIC FLOOR TILE: COMMERCIAL PORTLAND CEMENT GROUT, COMPLYING WITH ANSI

A118.7, SPECIFIED OR SUPPLIED BY LATEX MANUFACTURER.

B. CERAMIC WAII TILE: DRY-SET GROUT, COMPLYING WITH ANSI A118.7, SPECIFIED OR SUPPLIED

BY LATEX MANUFACTURER. USE LATEX ADDITIVE WITHOUT A RETARDER WITH DRY-SET GROUT.

1.07 FLOOR INSTALLATION METHODS:

A. CERAMIC FLOOR TILE:

I. LATEX-PORTLAND CEMENT MORTAR: ANSI A1O8.5.

2. CONCRETE SUBFLOORS, INTERIOR: TCA F122.

3. GROUT: LATEX-PORTLAND CEMENT, ANSI A1O8.IO.

1.07 SUBMIT SAMPLES OF MATERIAL TO BE PROVIDED.

SECTION 09 68 00 - CARPETING

1.01 CARPET SHALL BE BROADLOOM AS MANUFACTURED BY MONTEREY (TANDUS US INC.) OR AN

APPROVED EQUAL. BACKING SHALL BE CUSHION BACK.

1.02 TRANSITION REDUCER STRIP SHALL BE EXTRUDED OR MOLDED VINYL OF SIZE AND PROFILE

REQUIRED. MINIMUM 2 INCH ANCHORAGE FLANGE. COLOR SHALL BE AS SELECTED BY THE

CONTRACTING OFFICER.

1.03 ADHESIVES FOR CARPET AND TRANSITION REDUCER STRIP SHALL BE COMPATIBLE WITH THE

CARPET, TRANSITION REDUCER STRIP AND SUB-FLOORING. CARPET ADHESIVE SHALL BE

PRESSURE-SENSITIVE RELEASE TYPE.

1.04 GLUE CARPET DIRECTLY TO THE FLOOR SURFACE IN ACCORDANCE WITH THE

MANUFACTURER'S RECOMMENDATIONS.

1. CONCRETE SUBFLOORS, INTERIOR: TCA FI31.

1.05 SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA FOR ALL SPECIFIED ITEMS. SUBMIT

SAMPLES OF CARPET.

SECTION 09 51 00 - ACOUSTICAL CEILINGS

1.01 LAY-IN PANELS SHALL BE AS FOLLOWS:

A. ACPI: MINERAL FIBER PANEL MEETING ASTM E 1264, TYPE III, FORM 2, PATTERN CE, CLASS A, AS MANUFACTURED BY ARMSTRONG WORLD INDUSTRIES OR AN APPROVED EQUAL.

1.02 SUSPENDED GRID SHALL BE AS FOLLOWS:

A. WIDE-FACE, CAPPED, DOUBLE WEB, STEEL SUSPENSION SYSTEM (USE WITH ACP I): MAIN AND

CROSS RUNNERS ROLL FORMED FROM COLD-ROLLED STEEL SHEET, PREPAINTED,

ELECTROLYTICALLY ZINC-COATED, OR HOT-DIP GALVANIZED ACCORDING TO ASTM S 653, NOT LESS THAN G30 (Z90) COATING DESIGNATION, WITH PREFINISHED 15/16 INCH WIDE METAL CAPS ON

FLANGES.

I. STRUCTURAL CLASSIFICATION: HEAVY-DUTY SYSTEM.

2. FACE DESIGN: FLAT, FLUSH.

3. CAP MATERIAL: STEEL.

4. CAP FINISH: PAINTED WHITE, UNLESS OTHERWISE INDICATED.

1.03 HANGER WIRE SHALL BE GALVANIZED STEEL WIRE, ASTM A 6411, SOFT TEMPER, CLASS I COATING, SIZED SO THAT STRESS AT 3 TIMES HANGER DESIGN LOAD (ASTM C 635, TABLE I, DIRECT HUNG), WILL BE LESS THAN YIELD STRESS OF WIRE, BUT PROVIDE NOT LESS THAN 12 GAUGE.

1.04 PREPARATION AND INSTALLATION SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S

RECOMMENDATIONS. GRID SHALL BE LEVEL TO 1\8" IN 12'-0". HANGERS NOT MORE THAN 6" FROM

EACH END AND NOT MORE THAN 4'-0" O.C.

1.05 PROPERLY MARK ALL ACOUSTICAL TILES THAT CONCEAL VARIOUS MECHANICAL AND

ELECTRICAL EQUIPMENT BEFORE SETTING TILES IN PLACE.

SECTION 09 65 00 - RESILIENT FLOORING

1.01 VINYL COMPOSITION TILE (VCT) SHALL 12" X 12" X 1/8" THICK ARMSTRONG IMPERIAL TEXTURE

OR AN APPROVED EQUAL.

1.02 VINYL BASE SHALL BE 4" HIGH BY 1/8" THICK, COVE BASE AS MANUFACTURED BY JOHNSONITE

OR AN EQUAL. COLOR SHALL BE AS SELECTED BY THE CONTRACTING OFFICER FROM THE

MANUFACTURER'S COMPLETE LINE OF STANDARD COLORS. FURNISH IN ROLL MATERIAL, NOT

STRIPS.

1.03 ADHESIVES SHALL BE WATER RESISTANT AND AS RECOMMENDED BY THE MANUFACTURER.

SECTION 09 90 00 - PAINTS AND COATINGS

1.01 PAINT TO COMPLETION ALL ITEMS NOT HAVING A FACTORY FINISH AND WHICH

NORMALLY REQUIRE PAINT FOR PROTECTION AND/OR DECORATIVE REASONS. ALL EXPOSED

PIPING, DUCTWORK AND CONDUIT SHALL BE FINISH PAINTED UNDER THIS SECTION.

1.02 COATS SPECIFIED IN THIS SECTION ARE IN ADDITION TO COATS SPECIFIED IN OTHER

SECTIONS. ADDITIONAL COATS MAYBE REQUIRED TO OBTAIN A FULLY COVERED, WORKMANLIKE, PRESENTABLE JOB.

1.03 PAINT SHALL BE TOP QUALITY AND EQUAL TO OF ONE THE FOLLOWING MANUFACTURERS:

A. BENJAMIN MOORE AND CO., BRUNING; 1C1; MAB; PITTSBURGH PAINTS; PRATT AND LAMBERT OR

THE SHERWIN-WILLIAMS COMPANY.

1.04 COLORS SHALL BE AS SELECTED BY THE CONTRACTING OFFICER FROM THE

MANUFACTURER'S FULL LINE OF COLORS.

1.05 SURFACES TO BE PAINTED, INCLUDING PREVIOUSLY PAINTED SURFACES, SHALL BE

PREPARED AND ALL PAINT SHALL BE APPLIED IN ACCORDANCE WITH THE PAINT MANUFACTURER'S

INSTRUCTIONS.

1.06 PAINT SCHEDULE: PROVIDE THE FOLLOWING PAINT SYSTEMS FOR THE VARIOUS

SUBSTRATES, AS INDICATED.

A. INTERIOR:

1. PAINT SYSTEM NO. 1

SURFACE: INTERIOR FERROUS METAL.

DEGREE OF GLOSS: SEMI-GLOSS.

PRIMER: RUST INHIBITIVE PRIMER.

SECOND COAT: ACRYLIC LATEX

THIRD COAT: ACRYLIC LATEX.

2. PAINT SYSTEM NO.2

SURFACE: INTERIOR ZINC COATED METAL.

DEGREE OF GLOSS: SEMI-GLOSS.

PRIMER: GALVANIZED STEEL PRIMER.

SECOND COAT: ACRYLIC LATEX.

THIRD COAT: ACRYLIC LATEX.

3. PAINT SYSTEM NO.3

SURFACE: GYPSUM BOARD.

DEGREE OF GLOSS: EGGSHELL, UNLESS INDICATED OTHERWISE.

PRIMER: LATEX PRIMER SEALER.

SECOND COAT: VINYL ACRYLIC LATEX.

THIRD COAT: VINYL ACRYLIC LATEX.

4. PAINT SYSTEM NO.4

SURFACE: WOOD CLEAR NATURAL FINISH.

DEGREE OF GLOSS: SEMI-GLOSS.

STAIN COAT (ON CHERRY VENEER ONLY): WATER REDUCIBLE WIPING STAIN.

COLOR SHALL BE STNI MEDIUM RED CHERRY AS APPROVED BY THE OWNERS REPRESENTATIVE.

FILLER COAT: PASTE WOOD FILLER.

SECOND COAT: WATERBORNE POLYURETHANE VARNISH.

THIRD COAT: WATERBORNE POLYURETHANE VARNISH. SHEEN TO MATCH EXISTING; AND AS

APPROVED BY THE OWNER'S REPRESENTATIVE FOR CHERRY VENEER.

5. PAINT SYSTEM NO.5

SURFACE: WOOD - OPAQUE FINISH.

DEGREE OF GLOSS: SEMI-GLOSS.

PRIMER: VINYL ACRYLIC. LATEX ENAMEL UNDERBODY.

SECOND COAT: VINYL ACRYLIC LATEX.

THIRD COAT: VINYL ACRYLIC LATEX.

1.07 SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA. SUBMIT COLOR SAMPLES FOR

SELECTION.

DIVISION 10 - SPECIALTIES

SECTION 10 28 00 - TOILET AND BATH ACCESSORIES

1.01 UNLESS INDICATED OTHERWISE PROVIDE TOILET AND BATH ACCESSORIES AS

MANUFACTURED BY ONE OF THE FOLLOWING: AMERICAN SPECIALTIES, INC.; BOBRICK WASHROOM

EQUIPMENT; OR BRADLEY CORPORATION.

1.02 ACCESSORY SCHEDULE: ALL NUMBERS TAKEN FROM THE BOBRICK CATALOG UNLESS

INDICATED OTHERWISE.

A. TOWEL BAR, B-76737 X 24.

B. FOLDING SHOWER SEAT, B-5181.

C. PAPER TOWEL DISPENSER/RECEPTACLE, B-369, RECESSED.

D. COAT HOOK, B-6727.

E. TOILET PAPER DISPENSER, B-3888, RECESSED.

1.03 SUBMIT MANUFACTURER'S TECHNICAL PRODUCT DATA.

ARCHITECTURAL SPECIFICATIONS

D

C

B

A

2 3 4 5

R e v

Sheet

Sheet reference number:

A p p r.

D a te

D e s c ri p ti o n

M a rk

D a te

D e s ig n f ile n o

D e s ig n e d b y

D w n b y

C k d b y

R e v ie w e d b y

S u b m itt e d b y

C h ie f, D ra w in g c o d e

F ile n a m e

P lo t s c a le

P lo t d a te of

B U

IL

D

IN

G

E

Baltimore District of Engineers US Army Corps

S U

B M

IS

S

IO

N

-2

-0

S

U B

M

IS

S

IO

N

-2

-0

-3

-0

-3

-0

J W

S

J W

S H

K D

A B

A R

C H

IT

E

C T

U R

A L

S P

E C

IF

IC

A T

IO

N

S

A-501 11 21