Attachment 4 Sunflower Army Ammunition Plant
Remaining FR1 Foundation Inventory
1 of 4 Updated 16 Sep 2011
BLDG
NUMBER TITLE FND SWMU or AOC MEC Sewer
Inside FND Sewer Pipe Diameter
No. of MEC Drains
No. of Lines Exiting Fdn Drawing Number Applied
Pesticides
MEC
Samples Index
6869-1 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 604 6869-2 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 605 6869-3 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 606 6869-4 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 607 6869-5 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 608 6869-6 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 609 6869-7 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 610 6869-8 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 611 6869-9 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 612 6869-10 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 613 6869-11 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 614 6869-12 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 615 6869-13 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 616 6869-14 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 617 6869-15 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 618 6869-16 Paste Dry House FR1 AOC 12 0 - 0 Field Observation No 619
AOC 12 Total 0 0 0 0 C2013 Fume Stack FR1 AOC 16 4 8 1 7285-5-760 No 1 278 C3013 Fume Stack FR1 AOC 16 4 8 1 7285-5-760 No 1 318 2019 Boiling Tub House FR1 AOC 16 7 8 6 7285-U-254 No 1 279 2022 Beater House FR1 AOC 16 3 - sump S-36420 No 1 282 A2022 Control House FR1 AOC 16 0 - 0 S-36874 No 283 2024 Poacher and Blender House FR1 AOC 16 459 8,15,24 4 7285-U-256 No 2 284 3019 Boiling Tub House FR1 AOC 16 7 8 6 7285-U-255 No 1 320 3022 Beater House FR1 AOC 16 3 - sump S-36420 No 1 323 A3022 Control House FR1 AOC 16 0 - 0 S-36874 No 324
3024 Poacher and Blending House FR1 AOC 16 201 8 4 S-36481;
7285-U-256 No 1 325 C4013 Fume Stack FR1 AOC 16 4 8 1 7285-5-760 No 1 364 4019 Boiling Tub House FR1 AOC 16 13 8 4 11 S-36781 Yes 1 366 4022 Beater House FR1 AOC 16 3 - sump 6 S-36420 Yes 1 369 A4022 Control House FR1 AOC 16 0 - 0 0 S-36874 Yes 370 4024 Poacher & Blending House FR1 AOC 16 12 8 4 12 7285-8-110 Yes 1 371 5022 Beater House FR1 AOC 16 3 - sump 5 S-36420 Yes 1 406 A5022 Control House FR1 AOC 16 0 - 0 0 S-36874 Yes 407 5026-2 Final Wringer House FR1 AOC 16 3 - sump 2 S-42701 No 1 411 5046 Beater House FR1 AOC 16 3 - sump S-42707 No 1 413 A5046 Control House FR1 AOC 16 0 - 0 S-36874 No 414
AOC 16 Total 729 31 36 16 904 Sulphuric Acid Concentrator FR1 AOC 17 0 - 0 Field Observation No 72 C904 Weak Acid Storage Tank FR1 AOC 17 0 - 1 Field Observation No 73 D904 Weak Acid Storage Tank FR1 AOC 17 0 - 1 Field Observation No 74 E904 Stage 1 Distillate Tank FR1 AOC 17 0 - 1 Field Observation No 75 F904 Stage 2 Distillate Tank FR1 AOC 17 0 - 1 Field Observation No 76 G904 Stage 3 Distillate Tank FR1 AOC 17 0 - 1 Field Observation No 77 H904 #1 Product Acid Storage Tank FR1 AOC 17 0 - 1 Field Observation No 78 I904 #2 Product Acid Storage Tank FR1 AOC 17 0 - 1 Field Observation No 79 J904 Caustic Storage Tank FR1 AOC 17 0 - 1 Field Observation No 80 K904 NQ Waste Water Treatment Tank FR1 AOC 17 0 - 1 Field Observation No 81 L904 Lime Slurry Tank FR1 AOC 17 0 - 1 Field Observation No 82 M904 Lime Storage Silo and Slaker Tank FR1 AOC 17 0 - 1 Field Observation No 83 A927 Sump (Explosive) FR1 AOC 17 0 - 0 Field Observation No 86 B927 Sump (Acid) FR1 AOC 17 0 - 0 Field Observation No 87 A928-3 Scrubber, Conveyor Dryer Vacuum FR1 AOC 17 0 - 0 Field Observation No 88 A928-4 Scrubber, Conveyor Dryer Vacuum FR1 AOC 17 0 - 0 Field Observation No 89 928-5 Conveyor H 585 FR1 AOC 17 0 - 0 Field Observation No 90 A928-5 Scrubber, Conveyor Dryer Vacuum FR1 AOC 17 0 - 0 Field Observation No 91 9015 Guanidine Rest House FR1 AOC 17 0 - 0 Field Observation No 631 9017 Pack House FR1 AOC 17 19 4 2 SFAAP 15600 No 1 632 A9017 Dry Vacuum Scrubber FR1 AOC 17 0 - 0 Field Observation No 633 B9017 Dust Collector Scrubber FR1 AOC 17 0 - 0 Field Observation No 634 C9031 Sulfuric Acid Storage Tank FR1 AOC 17 0 - 0 Field Observation No 635
9040 Wet Guanidine Nitrate FR1 AOC 17 21 - 2
SFAAP 14994;
SFAAP 14995 No 1 636
F9040 Decanters FR1 AOC 17 0 - 0 Field Observation No 637 9041 Dry Guanidine Nitrate FR1 AOC 17 0 - 0 Field Observation No 1 638
Remaining FR1 Foundation Inventory
2 of 4 Updated 16 Sep 2011
BLDG
NUMBER TITLE FND SWMU or AOC MEC Sewer
Inside FND Sewer Pipe Diameter
No. of MEC Drains
No. of Lines Exiting Fdn Drawing Number Applied
Pesticides
MEC
Samples Index
A9041 Dryer Vapor Scrubber FR1 AOC 17 0 - 0 Field Observation No 639 B9041 Dust Collector Scrubber FR1 AOC 17 0 - 0 Field Observation No 640 H9041 North Mother Liquor Surge Tank FR1 AOC 17 0 - 0 Field Observation No 641
9042 Wet Nitroguanidine FR1 AOC 17 397 - 21
SFAAP 15307;
SFAAP 15308;
SFAAP 15309 No 2 642
E9042 Recovered SA Storage Tank FR1 AOC 17 0 - 0 Field Observation No 643 H9042 Oleum Nitric Acid Storage FR1 AOC 17 0 - 0 Field Observation No 644 9043 Dry Guanidine FR1 AOC 17 11 - 1 SFAAP 15520 No 1 645 A9043 Dryer Vent Scrubber FR1 AOC 17 0 - 0 Field Observation No 646 B9043 Dust Collector FR1 AOC 17 0 - 0 Field Observation No 647
AOC 17 Total 448 37 0 6 113-11 Unloading Station FR1 SWMU 24 0 - 0 0 Field Observation Yes 2 113-20 Unloading Station (Glyc) FR1 SWMU 24 0 - 0 Field Observation No 4 554-8 Area Oil House N.G. Area FR1 SWMU 24 0 - 0 Field Observation No 39 600-6 Solvent Storage (4 Tanks) FR1 SWMU 24 0 - 0 Field Observation No 53 A600-6 Pump House FR1 SWMU 24 0 - 0 Field Observation No 54 926 Slurry Analysis House FR1 SWMU 24 0 - 0 Field Observation No 84 A926 Building Sump #5 FR1 SWMU 24 0 - 0 Field Observation No 85 5653 GlycerineTanks & Storage House FR1 SWMU 24 0 - 0 Field Observation No 424 A5653 Pump House FR1 SWMU 24 0 - 0 Field Observation No 425 5654 NG Emulsion Transfer System FR1 SWMU 24 0 - 0 Field Observation No 426 5655-1 Mixed Acid Storage & Weigh House FR1 SWMU 24 0 - 0 Field Observation No 427 5655-2 N.G. Mixed Acid Storage & Weigh House FR1 SWMU 24 0 - 0 Field Observation No 428 5655-3 Mixed Acid Tanks FR1 SWMU 24 0 - 0 Field Observation No 429 5656-1 Glycerine Tank (Heated) FR1 SWMU 24 0 - 0 Field Observation No 430 A5656-1 Pump House FR1 SWMU 24 0 - 0 0 Field Observation Yes 431 5656-2 Glycerine Tank (Heated) FR1 SWMU 24 0 - 0 Field Observation No 432 A5656-2 Pump House FR1 SWMU 24 0 - 0 Field Observation No 433 5657-1 N.G. Nitrating & Separating House FR1 SWMU 24 0 - 0 Field Observation No 434 A5657-1 Soda Ash Store House FR1 SWMU 24 0 - 0 Field Observation No 435 B5657-1 Catch Tank House FR1 SWMU 24 0 - 0 Field Observation No 436 5657-2 N.G. Nitrating & Separating House FR1 SWMU 24 0 - 0 Field Observation No 437 A5657-2 Soda Ash Store House FR1 SWMU 24 0 - 0 Field Observation No 438 B5657-2 Catch Tank House FR1 SWMU 24 0 - 0 Field Observation No 439 5657-3 N.G. Nitrating & Separating House FR1 SWMU 24 0 - 0 Field Observation No 440 A5657-3 Soda Ash Store House FR1 SWMU 24 0 - 0 Field Observation No 441 B5657-3 Catch Tank House FR1 SWMU 24 0 - 0 Field Observation No 442 5658 NG Gutters FR1 SWMU 24 0 - 0 Field Observation No 443 5660-1 Refrigerating House FR1 SWMU 24 96 2,3,6 8 1 S-39380 Yes 1 444 5660-2 Refrigerating House FR1 SWMU 24 42 2,3,6 4 S-39471 No 1 445 5663-2 Spent Acid Storage FR1 SWMU 24 4 - 1 7285-5-235 No 1 446 5663-3 Spent Acid Storage FR1 SWMU 24 4 - 1 7285-5-235 No 1 447 A5663-3 Control House/Soda Ash Store House FR1 SWMU 24 0 - 0 Field Observation No 448 5665 Spent Acid Storage FR1 SWMU 24 30 - 6 Estimate No 1 449 5667-1 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 450 A5667-1 Catch Tank Slum House FR1 SWMU 24 0 - 0 Field Observation No 451 5667-2 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 452 A5667-2 Catch Tank Slum House FR1 SWMU 24 0 - 0 Field Observation No 453 5667-3 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 454 A5667-3 Catch Tank Slum House FR1 SWMU 24 0 - 0 Field Observation No 455 5667-4 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 456 A5667-4 Catch Tank Slum House FR1 SWMU 24 0 - 0 Field Observation No 457 5667-6 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 458 A5667-6 Catch Tank Slum House FR1 SWMU 24 0 - 0 Field Observation No 459 5667-7 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 460 A5667-7 Catch Tank Slum House FR1 SWMU 24 0 - 0 Field Observation No 461 5667-8 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 462 A5667-8 Catch Tank Slum House FR1 SWMU 24 0 - 0 Field Observation No 463 5667-9 Neutralizing & Store House FR1 SWMU 24 0 - 0 Field Observation No 464 5670-1 Pump & Catch Tank House FR1 SWMU 24 23 3 SAAP 10120 No 1 465 5670-2 Pump & Catch Tank House FR1 SWMU 24 2 1 SAAP 10119 No 1 466 5671-2 Acetone Weigh House FR1 SWMU 24 0 - 0 0 Field Observation Yes 468 5671-3 Acetone Weigh House FR1 SWMU 24 0 - 0 0 Field Observation Yes 469 5673-5 Pre Mix House FR1 SWMU 24 0 - 0 0 SAAP-9981 Yes 474 5673-6 Pre Mix House FR1 SWMU 24 0 - 0 0 SAAP-9981 Yes 475
Remaining FR1 Foundation Inventory
3 of 4 Updated 16 Sep 2011
BLDG
NUMBER TITLE FND SWMU or AOC MEC Sewer
Inside FND Sewer Pipe Diameter
No. of MEC Drains
No. of Lines Exiting Fdn Drawing Number Applied
Pesticides
MEC
Samples Index
5673-7 Pre Mix House FR1 SWMU 24 0 - 0 0 SAAP-9981 Yes 476 5673-8 Pre Mix House FR1 SWMU 24 0 - 0 0 SAAP-9981 Yes 477 5673-9 Pre Mix House FR1 SWMU 24 0 - 0 0 SAAP-9981 Yes 478 5673-10 Pre Mix House FR1 SWMU 24 0 - 0 0 SAAP-9981 Yes 479 5675 N.G. Change House FR1 SWMU 24 0 - 0 0 S-39175 Yes 483 5677 N.G. Area Offices FR1 SWMU 24 0 - 0 483.5 5678 N.G. Repair Shop FR1 SWMU 24 0 - 0 Field Observation Yes 484 5679-1 N.G. Buggy Storehouse FR1 SWMU 24 0 - 0 Field Observation No 485 5679-2 N.G. Buggy Storehouse FR1 SWMU 24 0 - 0 Field Observation No 486 5680 Soda Ash Store House FR1 SWMU 24 0 - 0 Field Observation No 487 5681-1 Intermediate Soda Store House FR1 SWMU 24 0 - 0 Field Observation No 488 5681-2 Intermediate Soda Store House FR1 SWMU 24 0 - 0 Field Observation No 489 5681-3 Intermediate Soda Store House FR1 SWMU 24 0 - 0 Field Observation No 490 5682 N.G. Laboratory FR1 SWMU 24 39 4 3 7285-10-746 No 1 491 5683 N.G. Compressor House FR1 SWMU 24 0 - 0 Field Observation No 492 5685 Soda & Glycerin Store House FR1 SWMU 24 0 - 0 Field Observation No 493 5720 N.C. Block Breaker House FR1 SWMU 24 2 8 1 S-39206 No 1 494 5722 N.C. Weigh & Store House FR1 SWMU 24 0 - 0 Field Observation No 495 5801 N.C. Blender House FR1 SWMU 24 9 - 1 7285-6-462 No 1 496 A5801 Test Laboratory & Scale House FR1 SWMU 24 5 - 1 SOW 137 No 1 497 B5801 Elevator House FR1 SWMU 24 0 - 0 Field Observation No 498 5802-1 Pre Mix Paste House FR1 SWMU 24 18 - 1 S-43003 No 1 499 B5802-1 Elevator House FR1 SWMU 24 0 - 0 Field Observation No 500 5802-2 Pre Mix Paste House FR1 SWMU 24 18 - 1 S-43003 No 1 501 B5802-2 Elevator House FR1 SWMU 24 0 - 0 Field Observation No 502 5803-1 Paste Rest House FR1 SWMU 24 0 - 0 0 Field Observation Yes 503 5803-2 Paste Rest House FR1 SWMU 24 0 - 0 0 Field Observation Yes 504 5804-1 Final Mix Paste House FR1 SWMU 24 0 - 0 Field Observation No 505 E5804-1 Elevator House FR1 SWMU 24 3 - 1 1 7285-6-407 Yes 1 506 F5804-1 Catch Tank House FR1 SWMU 24 0 - 0 Field Observation No 507 5804-2 Final Mix Paste House FR1 SWMU 24 0 - 0 Field Observation No 508 E5804-2 Elevator House FR1 SWMU 24 3 - 1 1 7285-6-407 Yes 1 509 F5804-2 Catch Tank House FR1 SWMU 24 0 - 0 Field Observation No 510
5806 Pump & Heater House FR1 SWMU 24 74 - 5
SOW 360; S-
43033 No 1 511 5811 Chemical Store House FR1 SWMU 24 0 - 0 Field Observation No 512 5824 Chemical Preparation House FR1 SWMU 24 0 - 0 0 Field Observation Yes 513 5864 Wheeling Walks, Paste Area FR1 SWMU 24 0 - 0 Field Observation No 514 5865 Change House (200 Man) FR1 SWMU 24 0 - 0 0 TM 929 Yes 515 5920-1 N.C. Block Breaker House FR1 SWMU 24 2 8 1 S-39206 No 1 541 5920-2 N.C. Block Breaker House FR1 SWMU 24 2 8 1 1 S-39206 Yes 1 542 5920-3 N.C. Block Breaker House FR1 SWMU 24 2 8 1 1 S-39206 Yes 1 543 5922-1 N.C. Weigh & Store House FR1 SWMU 24 0 - 0 0 Field Observation Yes 544 5922-2 N.C. Weigh & Store House FR1 SWMU 24 0 - 0 0 Field Observation Yes 545 5950 N.C. Rest House FR1 SWMU 24 0 - 0 Field Observation No 578 5974-1 Pre Mix Rest House FR1 SWMU 24 0 - 0 Field Observation No 581 5974-2 Pre Mix Rest House FR1 SWMU 24 0 - 0 Field Observation No 582 5974-3 Pre Mix Rest House FR1 SWMU 24 0 - 0 Field Observation No 583 5974-4 Pre Mix Rest House FR1 SWMU 24 0 - 0 Field Observation No 584 6655 N.G. Mixed Acid Stoarage & Weigh House FR1 SWMU 24 0 - 0 Field Observation No 588 6656 Glycerin Tank Heated FR1 SWMU 24 0 - 0 Field Observation No 589 6657 N.G. Nitrating and Separating House FR1 SWMU 24 0 - 0 Field Observation No 590 6658 N.G. Gutters FR1 SWMU 24 0 - 0 Field Observation No 591 6660 Refrigerating House FR1 SWMU 24 42 2,3,6 4 S-39471 No 1 592 6663 Spent Acid Storage House FR1 SWMU 24 4 - 1 7285-5-235 No 593 6667-1 Neutralization and Store House FR1 SWMU 24 0 - 0 Field Observation No 594 6667-2 Neutralization and Store House FR1 SWMU 24 0 - 0 Field Observation No 595 6679 N.G. Buggy House FR1 SWMU 24 0 - 0 Field Observation No 596 6683 Intermediate Spent Acid Blowpipe House FR1 SWMU 24 4 - 1 S-46674 No 1 597 6802 Premix Paste House FR1 SWMU 24 4 - 1 S-46675 No 1 598 6803-7 Paste Rest House FR1 SWMU 24 0 - 0 Field Observation No 599 6803-8 Paste Rest House FR1 SWMU 24 0 - 0 Field Observation No 600 6832 Diethylphthalate Storage FR1 SWMU 24 0 - 0 Field Observation No 601 6833-1 Diethylphthalate Weigh House FR1 SWMU 24 0 - 0 Field Observation No 602 6833-2 Diethylphthalate Weigh House FR1 SWMU 24 0 - 0 Field Observation No 603 6872 Bag Cleaning House FR1 SWMU 24 0 - 0 Field Observation No 620
Remaining FR1 Foundation Inventory
4 of 4 Updated 16 Sep 2011
BLDG
NUMBER TITLE FND SWMU or AOC MEC Sewer
Inside FND Sewer Pipe Diameter
No. of MEC Drains
No. of Lines Exiting Fdn Drawing Number Applied
Pesticides
MEC
Samples Index
9801 N.C. Consistency Control House FR1 SWMU 24 0 - 0 Field Observation No 648 B9801 Building Sump #1 FR1 SWMU 24 0 - 0 Field Observation No 649 9802 Continuous Mix House FR1 SWMU 24 0 - 0 Field Observation No 650 B9802 Building Sump #4 FR1 SWMU 24 0 - 0 Field Observation No 651 9898-3 Main Sump #2 FR1 SWMU 24 1 - 0 Field Observation No 1 652
SWMU 24 Total 433 49 5 23 175-11 Contaminated Waste Processor FR1 SWMU 31 0 - 0 Field Observation No 11 A175-11 Storage Pad FR1 SWMU 31 0 - 0 Field Observation No 12 D175-11 Sump FR1 SWMU 31 0 - 0 Field Observation No 13 E175-11 Sump FR1 SWMU 31 0 - 0 Field Observation No 14
SWMU 31 Total 0 0 0 0 690-1 Calcium Carbonate Storage (was 8878-1) FR1 SWMU 43 0 - 0 Field Observation No 55 690-2 Calcium Carbonate Storage (was 8878-2) FR1 SWMU 43 0 - 0 Field Observation No 56 690-3 Calcium Carbonate Storage (was 8878-3) FR1 SWMU 43 0 - 0 Field Observation No 57 690-4 Calcium Carbonate Storage (was 8878-4) FR1 SWMU 43 0 - 0 Field Observation No 58
SWMU 43 Total 0 0 0 0 580 Decontamination Oven Facility FR1 SWMU 46 0 - 0 Field Observation No 41
SWMU 46 Total 0 0 0 0
A600-1 Pump House FR1 SWMU 65 8 4 1 1 S-45114 Yes 1 42 3502 Ether Still House FR1 SWMU 65 166 4,8 9 1 S-40013 Yes 1 334
SWMU 65 Total 174 10 2 2 708-2 Denitrated Sulfuric Storage (2 Tanks) FR1 SWMU 67 0 - 2 Field Observation No 64 A728 Oleum Plant Office & Shops NFR SWMU 67 0 - 0 No 64.5
SWMU 67 Total 0 2 0 0
TOTALS 1,784 129 43 47 653
SUNFLOWER ARMY AMMUNITION PLANT COST ASSUMPTIONS
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 1 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
ESTIMATED ENVIRONMENTAL SAMPLES AND T&D SOIL
VOLUMES FOR EACH SWMU OR AOC SITE
SAMPLE NUMBERS DO NOT INCLUDE QA
SWMU-24 NITROGLYCERINE AND PASTE MIX AREA
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 16,676 Explosive Foundations Worked in ICM Work Plan for AOC 23 ICM CONCRETE SLAB AREA SQ FT 48,370 From Remaining FR-1 Foundations workbook; 20% is TBP area ICM 900 SQ FT UNDER SLAB CONFIRMATION SAMPLING GRID SAMPLE 62 Quantity includes additional 15% QC samples ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 11 Assumes 20% of sampled grids require excavation (1 foot avg.)
ICM 900 SQ FT GRIDS REQUIRING POST-X CONF SAMPLES EACH 11 Assume 20% of Post-X Conf Sample Grids fail & require add'l excav.
ICM UNDER SLAB CONTAMINATED SOIL VOLUME BCY 433
ICM CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 542
ICM CONTAMINATED RIND SOIL VOLUME BCY 1,077 BASED ON FINAL RIND SOILS DATA REPORT (AECOM, Nov 2017
ICM CONTAMINATED RIND SOIL VOLUME (W 25% FLUFF) CY 1,346
ICM CONFIRMATION SAMPLES SAMPLE 75
RCRA Metals, manganese, explosives (including NC, NG and NQ), SVOCs, VOCs, TPH-DRO, TPH-GRO, nitrate/nitrite, ammonia, sulfate, pesticides, pH
ICM
UNDER CONTAMINATED SOIL STOCKPILE CONFIRMATION
SAMPLES SAMPLE 5
Required sampling for areas where contaminated soil was stockpiled, after stockpile is removed.
ICM CONTAMINATED SOIL DISPOSAL SAMPLES SAMPLE 5 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM CLEANUP AND LANDSCAPING ACRES 6
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 16,676
ICM PERIMETER BURN DEBRIS/ACM ASSUMED WIDTH FT 12 ACM debris resulting from burning buildings with asbestos in place
ICM POTENTIAL BURN DEBRIS/ACM AREA SQ FT 200,112
ICM AVERAGE BURN DEBRIS/ACM DEPTH FT 2
ICM BURN DEBRIS/ACM SOIL VOLUME BCY 8,894 Assumes 60% of grid perimeter fails ACM scrape inspection
ICM BURN DEBRIS/ACM SOIL VOLUME (W 25% FLUFF) CY 11,117
ICM POST-ACM EXC. CONFIRMATION SAMPLES SAMPLE 133
ICM BURN DEBRIS/ACM IN BASEMENTS VOLUME CY 290
ICM TOTAL BURN DEBRIS/ACM VOLUME CY 11,408
ICM TOTAL ACM/BURN CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 14,259
ICM UNDER ACM CONTAMINATED SOIL STOCKPILE CONFIRM SAMPLES SAMPLE 29
after stockpile is removed.
ICM ACM DISPOSAL SAMPLES SAMPLE 33 TCLP (Metals), Corrosivity, Ignitability, Reactivity
279 TOTAL ESTIMATED SAMPLES FOR SWMU-24
16,147 TOTAL ESTIMATED SWMU-24 CY OF ENVIR. SOILS FOR T&D
SWMU-31 CONTAMINATED WASTE PROCESSOR/ EVAPORATIVE LAGOONS NO ACM ASSUMED
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 712 Explosive Foundations Worked in ICM Work Plan for AOC 23 ICM CONCRETE SLAB AREA SQ FT 10,244 From Remaining FR-1 Foundations workbook ICM 900 SQ FT UNDER SLAB CONFIRMATION SAMPLING GRID SAMPLE 13 Quantity includes additional 15% QC samples ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 2 Assumes 20% of sampled grids require excavation (1 foot avg.)
ICM 900 SQ FT GRIDS REQUIRING POST-X CONF SAMPLES EACH 2 Assume 20% of Post-X Conf Sample Grids fail & require add'l excav.
ICM UNDER SLAB CONTAMINATED SOIL VOLUME BCY 67
ICM CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 83
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 2 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
ICM CONTAMINATED RIND SOIL VOLUME BCY 20 BASED ON FINAL RIND SOILS DATA REPORT (AECOM, Jan 2018)
ICM CONTAMINATED RIND SOIL VOLUME (W 25% FLUFF) CY 25
ICM CONFIRMATION SAMPLES SAMPLE 16 RCRA Metals, SVOCs, Dioxins
ICM
UNDER CONTAMINATED SOIL STOCKPILE CONFIRMATION
SAMPLES SAMPLE 1
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM CLEANUP AND LANDSCAPING ACRES 2
18 TOTAL ESTIMATED SAMPLES FOR SWMU-31
108 TOTAL ESTIMATED SWMU-31 CY OF ENVIR. SOILS FOR T&D
SWMU-43 TUNNEL DRYERS NO ACM ASSUMED
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 2,591 Explosive Foundations Worked in ICM Work Plan for AOC 23 ICM CONCRETE SLAB AREA SQ FT 17,124 From Remaining FR-1 Foundations workbook ICM 900 SQ FT UNDER SLAB CONFIRMATION SAMPLING GRID SAMPLE 22 Quantity includes additional 15% QC samples ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 4 Assumes 20% of sampled grids require excavation (1 foot avg.)
ICM 900 SQ FT GRIDS REQUIRING POST-X CONF SAMPLES EACH 4 Assume 20% of Post-X Conf Sample Grids fail & require add'l excav.
ICM UNDER SLAB CONTAMINATED SOIL VOLUME BCY 167
ICM CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 208
ICM CONTAMINATED RIND SOIL VOLUME BCY 0 BASED ON FINAL RIND SOILS DATA REPORT (AECOM, July 2017
ICM CONTAMINATED RIND SOIL VOLUME (W 25% FLUFF) CY 0
ICM CONFIRMATION SAMPLES SAMPLE 26
RCRA Metals, Manganese, SVOC-Phthalates, Explosives (including NC, NG, NQ, GN), Nitrate, Sulfate, Ammonia, Pesticides
ICM
UNDER CONTAMINATED SOIL STOCKPILE CONFIRMATION
SAMPLES SAMPLE 1
Required sampling for areas where contaminated soil was stockpiled, after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM CLEANUP AND LANDSCAPING ACRES 6
29 TOTAL ESTIMATED SAMPLES FOR SWMU-43
208 TOTAL ESTIMATED SWMU-43 CY OF ENVIR. SOILS FOR T&D
SWMU-46 DECONTAMINATION OVEN NO ACM ASSUMED
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 116 Explosive Foundations Worked in ICM Work Plan for AOC 23 ICM CONCRETE SLAB AREA SQ FT 462 From Remaining FR-1 Foundations workbook; 20% is TBP area ICM 900 SQ FT UNDER SLAB CONFIRMATION SAMPLING GRID SAMPLE 1 Quantity includes additional 15% QC samples ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 0 Assumes 20% of sampled grids require excavation (1 foot avg.)
ICM 900 SQ FT GRIDS REQUIRING POST-X CONF SAMPLES EACH 0 Assume 20% of Post-X Conf Sample Grids fail & require add'l excav.
ICM UNDER SLAB CONTAMINATED SOIL VOLUME BCY 33
ICM CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 42
ICM CONTAMINATED RIND SOIL VOLUME BCY 76 BASED ON FINAL RIND SOILS DATA REPORT (AECOM, Jan 2018)
ICM CONTAMINATED RIND SOIL VOLUME (W 25% FLUFF) CY 95
ICM CONFIRMATION SAMPLES SAMPLE 1 Lead, Dioxins
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 3 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
ICM
UNDER CONTAMINATED SOIL STOCKPILE CONFIRMATION
SAMPLES SAMPLE 1
Required sampling for areas where contaminated soil was stockpiled, after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM CLEANUP AND LANDSCAPING ACRES 6
3 TOTAL ESTIMATED SAMPLES FOR SWMU-46
137 TOTAL ESTIMATED SWMU-46 CY OF ENVIR. SOILS FOR T&D
SWMU-65 TANK FARM
ICM LINEAR FEET AROUND TBP EXPLOSIVE FOUNDATIONS FT 301 TEMPORARY BURN PADS
ICM RIND SOIL SAMPLES OF TBP EXPLOSIVE FOUNDATIONS SAMPLE 12 10 + 2 = 12 Samples ICM RIND SOIL STEP OUT SAMPLES SAMPLE 6 15% TMCL exceedances, 2 Samples x 3 ICM ADDITIONAL RIND SOIL STEP OUT SAMPLES SAMPLE 3 5% TMCL exceedances, 1 Sample x 3 ICM 900 SQ FT GRIDS REQUIRING RE-REMEDITION EACH 1 25% of Grids, excavate an additional 1 foot deep to obtain clean soil ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 4 Estimated grids requiring excavation
ICM SOIL CONTAMINATION DEPTH FT 1
ICM SOIL CONTAMINATION AREA SQ FT 3,600
ICM CONTAMINATED SOIL VOLUME CY 133
ICM CONFIRMATION SAMPLES SAMPLE 4
RCRA Metals, Manganese, 2,4-DNT, NC, SVOCs, VOCs, TPH-DRO, and TPH-GRO
ICM CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLES SAMPLE 1 Required sampling for areas where contaminated soil was stockpiled, after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity ICM TEMPORARY BURN PADS - LINEAR FEET OF RIND SOIL FT 301 ACM debris resulting from burning buildings with asbestos in place
ICM RIND BURN DEBRIS/ACM WIDTH FT 12
ICM RIND BURN DEBRIS/ACM AREA SQ FT 2,408
ICM RIND BURN DEBRIS/ACM DEPTH FT 1
ICM RIND BURN DEBRIS/ACM VOLUME CY 89
ICM CONFIRMATION SAMPLES SAMPLE 3
ICM BURN DEBRIS/ACM IN BASEMENTS VOLUME CY 290
ICM TOTAL BURN DEBRIS/ACM VOLUME CY 379
ICM ACM CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLES SAMPLE 1 after stockpile is removed.
ICM ACM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM TEMPORARY BURN PADS - FR1 SUBFOUNDATION SLAB AREA SQ FT 3,235
ICM INITIAL UNDER SLAB 900 sq ft GRID SOIL SAMPLES SAMPLE 6 4 + 2 = 6 Samples ICM 900 SQ FT GRIDS REQUIRING REMEDITION EACH 1 15% TMCL exceedances; excavate 1 foot deep ICM 900 SQ FT GRIDS REQUIRING RE-REMEDITION EACH 1 25% of Grids, excavate an additional 1 foot deep to obtain clean soil
ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 2
ICM SOIL CONTAMINATION DEPTH FT 1
ICM SOIL CONTAMINATION AREA SQ FT 1,800
ICM CONTAMINATED SOIL VOLUME CY 68
ICM EXPLOSIVES BLENDED CONTAMINATED SOIL VOLUME CY 6 5% of total square feet of explosive soil blended to <10%
ICM TOTAL CONTAMINATED SOIL VOLUME CY 74
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 4 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
ICM CONFIRMATION SAMPLES (TOTAL) SAMPLE 2
ICM CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLES SAMPLE 1 after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity ICM INITIAL SEWER INSIDE FDN TRENCH SAMPLES SAMPLE 7 1 Five-point composite sample every foundation containing sewers ICM LENGTH OF EXPLOSIVE SEWER TRENCH INSIDE FOUNDATIONS FT 224 174 horizontal ft + (5' x 10) linear ft (drains, 5' per drain)
ICM WIDTH OF EXPLOSIVE SEWER TRENCH FT 6
ICM SOIL CONTAMINATION LENGTH FT 34 15% of linear feet with TMCL exceedances
ICM SOIL CONTAMINATION DEPTH FT 1
ICM TEMPORARY BURN PADS - SOIL CONTAMINATION AREA SQ FT 202
ICM CONTAMINATED SOIL VOLUME CY 7
ICM SEWER TRENCH REQUIRING RE-REMEDITION LENGTH FT 8 1 foot deep to obtain clean soil
ICM RE-REMEDIATION CONTAMINATED SOIL VOLUME CY 3
ICM EXPLOSIVES BLENDED CONTAMINATED SOIL VOLUME CY 7 15% of total linear feet of explosive soil blended to <10%
ICM TOTAL CONTAMINATED SOIL VOLULME SEWER INSIDE FDN CY 18
ICM CONFIRMATION SAMPLES SAMPLE 1
ICM CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLES SAMPLE 1 after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity ICM SEWER IN PESTICIDE FOUNDATIONS LENGTH FT 174 Pesticide containing soil moved to excavate explosive sewers
ICM SEWER IN PESTICIDE FOUNDATIONS WIDTH FT 6
ICM SEWER IN PESTICIDE FOUNDATIONS DEPTH FT 5 TEMPORARY BURN PADS
ICM SEWER IN PESTICIDE FOUNDATIONS VOLUME CY 193
ICM SEWER IN PESTICIDE FOUNDATIONS DISPOSAL SAMPLES SAMPLE 1
SAAP-065 Total Environmental Samples SAMPLE 54 SAAP-065 Total Contaminated Soil Excavation Volume CY 798 SAAP-065 Total Contaminated Soil Disposal Weight TON 1197
SWMU-67 SOUTH ACID AREA
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 296 TEMPORARY BURN PADS
ICM RIND SOIL SAMPLES OF EXPLOSIVE FOUNDATIONS SAMPLE 13 10 + 3 = 13 Samples ICM RIND SOIL STEP OUT SAMPLES SAMPLE 6 15% TMCL exceedances, 2 Samples x 3 ICM ADDITIONAL RIND SOIL STEP OUT SAMPLES SAMPLE 3 5% TMCL exceedances, 1 Sample x 3
ICM 900 SQ FT GRIDS REQUIRING RE-REMEDITION EACH 1 25% of Grids, excavate an additional 1 foot deep to obtain clean soil ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 4 Estimated grids requiring excavation
ICM SOIL CONTAMINATION DEPTH FT 2
ICM SOIL CONTAMINATION AREA SQ FT 3,600
ICM CONTAMINATED SOIL VOLUME CY 267
ICM CONFIRMATION SAMPLES SAMPLE 4
RCRA Metals, Hexavalent Chromium, Manganese, Nickel, Vanadium, SVOCs,VOCs,TPH-DRO,TPH-GRO, NG, Nitrate,Sulfate, Ammonia, H
ICM CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLES SAMPLE 1
Required sampling for areas where contaminated soil was stockpiled, after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity ICM TEMPORARY BURN PADS - LINEAR FEET OF RIND SOIL FT 296 ACM debris resulting from burning buildings with asbestos in place
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 5 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
ICM RIND BURN DEBRIS/ACM WIDTH FT 8
ICM RIND BURN DEBRIS/ACM AREA SQ FT 2,368
ICM RIND BURN DEBRIS/ACM DEPTH FT 1
ICM RIND BURN DEBRIS/ACM VOLUME CY 88
ICM CONFIRMATION SAMPLES SAMPLE 3
ICM BURN DEBRIS/ACM IN BASEMENTS VOLUME CY 290
ICM TOTAL BURN DEBRIS/ACM VOLUME CY 378
ICM ACM CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLES SAMPLE 1 after stockpile is removed.
ICM ACM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM TEMPORARY BURN PADS - FR1 SUBFOUNDATION SLAB AREA SQ FT 6,529
ICM INITIAL 900 sq ft GRID SOIL SAMPLES SAMPLE 10 7 + 3 = 10 Samples ICM 900 SQ FT GRIDS REQUIRING REMEDITION EACH 2 15% TMCL exceedances; excavate 1 foot deep ICM 900 SQ FT GRIDS REQUIRING RE-REMEDITION EACH 1 25% of Grids, excavate an additional 1 foot deep to obtain clean soil
ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 3
ICM SOIL CONTAMINATION DEPTH FT 1
ICM SOIL CONTAMINATION AREA SQ FT 2,630
ICM CONTAMINATED SOIL VOLUME CY 97
ICM EXPLOSIVES BLENDED CONTAMINATED SOIL VOLUME CY 12 5% of total square feet of explosive soil blended to <10%
ICM TOTAL CONTAMINATED SOIL VOLUME CY 110
ICM CONFIRMATION SAMPLES (TOTAL) SAMPLE 3
ICM CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLES SAMPLE 1 after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 1 TCLP (Metals), Corrosivity, Ignitability, Reactivity
SAAP-067 Total Environmental Samples SAMPLE 47 SAAP-067 Total Contaminated Soil Excavation Volume CY 754 SAAP-067 Total Contaminated Soil Disposal Weight TON 1131
AOC 12 AOC 12 - PASTE AIR DRY FACILITIES NO ACM ASSUMED
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 5,136 Explosive Foundations Worked in ICM Work Plan for AOC 23 ICM CONCRETE SLAB AREA SQ FT 44,960 From Remaining FR-1 Foundations workbook ICM 900 SQ FT UNDER SLAB CONFIRMATION SAMPLING GRID SAMPLE 57 Quantity includes additional 15% QC samples ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 10 Assumes 20% of sampled grids require excavation (1 foot avg.)
ICM 900 SQ FT GRIDS REQUIRING POST-X CONF SAMPLES EACH 10 Assume 20% of Post-X Conf Sample Grids fail & require add'l excav.
ICM UNDER SLAB CONTAMINATED SOIL VOLUME BCY 433
ICM CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 542
ICM CONTAMINATED RIND SOIL VOLUME BCY 571 BASED ON FINAL RIND SOILS DATA REPORT (AECOM, Nov 2017
ICM CONTAMINATED RIND SOIL VOLUME (W 25% FLUFF) CY 714
ICM CONFIRMATION SAMPLES SAMPLE 69 RCRA Metals, Antimony, Copper, Manganese, Explosives (including ICM UNDER CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLE 4 Required sampling for areas where contaminated soil was stockpiled, ICM DISPOSAL SAMPLES SAMPLE 4 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM CLEANUP AND LANDSCAPING ACRES 6
ICM LINEAR FEET AROUND EXPLOSIVE FOUNDATIONS FT 5,136
ICM PERIMETER BURN DEBRIS/ACM ASSUMED WIDTH FT 12 ACM debris resulting from burning buildings with asbestos in place
ICM POTENTIAL BURN DEBRIS/ACM AREA SQ FT 61,632
ICM AVERAGE BURN DEBRIS/ACM DEPTH FT 2
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 6 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
ICM BURN DEBRIS/ACM SOIL VOLUME BCY 2,739
ICM BURN DEBRIS/ACM SOIL VOLUME (W 25% FLUFF) CY 3,424
ICM POST-ACM EXC. CONFIRMATION SAMPLES SAMPLE 41
ICM BURN DEBRIS/ACM IN BASEMENTS VOLUME CY 290
ICM TOTAL BURN DEBRIS/ACM VOLUME CY 3,714
ICM TOTAL ACM/BURN CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 4,643
ICM UNDER ACM CONTAMINATED SOIL STOCKPILE CONFIRM SAMPLES SAMPLE 9 Required sampling for areas where contaminated soil was stockpiled, ICM ACM DISPOSAL SAMPLES SAMPLE 11 TCLP (Metals), Corrosivity, Ignitability, Reactivity
138 TOTAL ESTIMATED SAMPLES FOR AOC 12
5,898 TOTAL ESTIMATED AOC 12 CY OF ENVIR. SOILS FOR T&D
AOC 16 AOC 16 - NC PRODUCTION LINES TBP QUANTITIES (See Attachment 9 for Wet NC Soils Info) ICM WET NC ACCOUNTS: PESTICIDE SOIL VOLUME (W 25% FLUFF) CY 14875 Based on BCY Pesticide Acct Quantity from Attachment 9 ICM WET NC ACCOUNTS: NON-PESTICIDE SOIL VOLUME (W 25% FLUFF) CY 5999 Based on BCY Non-Pesticide Acct Quantity from Attachment 9 ICM CONCRETE SLAB AREA SQ FT 117,487 = TBP slab areas for removal (from Remaining FR1 workbook) ICM 900 SQ FT UNDER SLAB CONFIRMATION SAMPLING GRID SAMPLE 150 Quantity includes 15% QC samples ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 26 Assumes 20% of sampled grids require excavation (1 foot avg.)
ICM 900 SQ FT GRIDS REQUIRING POST-X CONF SAMPLES EACH 26 Assume 20% of Post-X Conf Sample Grids fail & require add'l excav.
ICM UNDER SLAB CONTAMINATED SOIL VOLUME BCY 1,033
ICM UNDER SLAB CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 1,292
ICM CONTAMINATED RIND SOIL VOLUME BCY 6,310 Based on 1' excavation at 45' wide apron post TBP usage
ICM TBP BURN IMPACTED SOIL VOLUME (W 25% FLUFF) CY 7,888
ICM TBP RIND SOIL POST-X CONFIRMATION SAMPLES SAMPLE 189 Based on 3786 LF & 45' wide apron ICM TOTAL UNDER SLAB CONFIRMATION SAMPLES SAMPLE 181 RCRA Metals, Hexavalent Chromium, Cobalt, Iron, Manganese, ICM UNDER CONTAMINATED SOIL STOCKPILE CONFIRMATION SAMPLE 61 Required sampling for areas where contaminated soil was stockpiled, ICM DISPOSAL SAMPLES SAMPLE 61 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM CLEANUP AND LANDSCAPING ACRES 6
ICM LINEAR FEET AROUND TBP EXPLOSIVE FOUNDATIONS FT 3,786
ICM PERIMETER ACM BURN DEBRIS ASSUMED WIDTH FT 12 ACM debris resulting from burning buildings with asbestos in place
ICM POTENTIAL BURN DEBRIS/ACM AREA SQ FT 45,432
ICM AVERAGE ADD'L EXCAVATION DEPTH FOR ACM BURN DEBRIS FT 1.5
ICM BURN DEBRIS/ACM SOIL VOLUME BCY 1,514 Assumes 60% of grid perimeter fails initial TBP 1' scrape inspection
ICM BURN DEBRIS/ACM SOIL VOLUME (W 25% FLUFF) CY 1,893
ICM POST-ACM EXC. CONFIRMATION SAMPLES SAMPLE 30
ICM BURN DEBRIS/ACM IN BASEMENTS VOLUME CY 290
ICM TOTAL BURN DEBRIS/ACM VOLUME CY 2,183
ICM TOTAL ACM/BURN CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 2,729
ICM UNDER ACM CONTAMINATED SOIL STOCKPILE CONFIRM SAMPLES SAMPLE 5 Required sampling for areas where contaminated soil was stockpiled, ICM ACM DISPOSAL SAMPLES SAMPLE 6 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM
535 TOTAL ESTIMATED SAMPLES FOR AOC 16
32,782 TOTAL ESTIMATED AOC 16 CY OF ENVIR. SOILS FOR T&D
AOC 17 AOC 17 - NQ PRODUCTION FACILITIES NO ACM ASSUMED
ICM LINEAR FEET AROUND ALL EXPLOSIVE FOUNDATIONS FT 7,125 Explosive Foundations Worked in ICM Work Plan for AOC 23
ICM CONCRETE SLAB AREA (ALL) SQ FT 59,766 From Remaining FR-1 Foundations workbook; 20% is TBP area ICM 900 SQ FT UNDER SLAB CONFIRMATION SAMPLING GRID SAMPLE 76 Quantity includes additional 15% QC samples ICM TOTAL 900 SQ FT GRIDS REQUIRING EXCAVATION EACH 13 Assumes 20% of sampled grids require excavation (1 foot avg.)
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 7 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
ICM 900 SQ FT GRIDS REQUIRING POST-X CONF SAMPLES EACH 13 Assume 20% of Post-X Conf Sample Grids fail & require add'l excav.
ICM UNDER SLAB CONTAMINATED SOIL VOLUME BCY 533
ICM CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 667
ESTIMATED LINEAR FEET AROUND EXCLUDED TBP ACCOUNTS
9040/9041/9042/9043 FT 2,114
RIND SOIL SAMPLES AROUND TBP ACCTS 9040-9043 SAMPLE 54 Per provided Attachment 12
ADDITIONAL RIND SOIL STEP-OUT SAMPLES FOR ACCTs 9040-9043 SAMPLE 76 Assume 40% initial samples require 3-pt step-outs at 10' separation for clean-to-clean. 20% stepdown sgl-pt.
EST. CONTAMINATED RIND SOIL VOLUME FOR ACCTS 9040-9043 BCY 864 Assume Grids Exceeding Require Avg. 1' Excavation
CONTAMINATED 9040-9043 ACCTS RIND SOIL VOLUME (25% FLUFF) CY 1,080
ICM CONTAMINATED NON-TBP RIND SOIL VOLUME BCY 28 BASED ON FINAL RIND SOILS DATA REPORT (AECOM, Aug 2017)
ICM CONTAMINATED NON-TBP RIND SOIL VOLUME (W 25% FLUFF) CY 35
ICM CONFIRMATION SAMPLES SAMPLE 92
RCRA Metals, Hexavalent Chromium, Cobalt, Iron, Manganese, SVOCs, VOCs, NQ, GN, Ethylene Glycol, PCBs, TPH-DRO, Nitrate, Sulfate, Ammonia, Cyanide, Fluoride, pH
ICM
UNDER CONTAMINATED SOIL STOCKPILE CONFIRMATION
SAMPLES SAMPLE 2
Required sampling for areas where contaminated soil was stockpiled, after stockpile is removed.
ICM DISPOSAL SAMPLES SAMPLE 0 TCLP (Metals), Corrosivity, Ignitability, Reactivity
ICM CLEANUP AND LANDSCAPING ACRES 6
ICM EST. LINEAR FEET AROUND TBP ACCT 3754 FT 486
ICM PERIMETER TBP BURN IMPACTED SOIL WIDTH FT 45 Based on 1' excavation at 45' wide apron post TBP usage
ICM POTENTIAL TBP BURN IMPACTED SOIL AREA SQ FT 21,870
ICM INITIAL TBP BURN IMPACTED SOIL EXCAV. DEPTH (BY SOP) FT 1
ICM TBP BURN IMPACTED SOIL VOLUME BCY 810 Assumes 60% of grid perimeter fails ACM scrape inspection
ICM TBP BURN IMPACTED SOIL VOLUME (W 25% FLUFF) CY 1,013
ICM TBP BURN IMPACTED SOILS POST-EXC. CONFIRM SAMPLES SAMPLE 15
ICM BURN DEBRIS/ACM IN BASEMENTS VOLUME CY 290
ICM TOTAL BURN DEBRIS/ACM VOLUME CY 1,303
ICM TOTAL ACM/BURN CONTAMINATED SOIL VOLUME (W 25% FLUFF) CY 1,628
ICM UNDER ACM CONTAMINATED SOIL STOCKPILE CONFIRM SAMPLES SAMPLE 3 Required sampling for areas where contaminated soil was stockpiled, ICM ACM DISPOSAL SAMPLES SAMPLE 4 TCLP (Metals), Corrosivity, Ignitability, Reactivity
246 TOTAL ESTIMATED SAMPLES FOR AOC 17
2,743 TOTAL ESTIMATED AOC 17 CY OF ENVIR. SOILS FOR T&D
16 Rind Soil Sites 1.15 QC MULTIPLIER
900 CONFIRMATION SAMPLE CENTERS (SQ FT) - STANDARD
27 STOCKPILES CY to CF CONVERTER FOR CONFIRM SAMPLES
500 DISPOSAL SAMPLE FREQUENCY (CY)
0.15 TBP INITIAL RIND SOIL SAMPLE EXCEED TMCL FREQUENCY
0.05 TBP RIND SOIL STEPOUT SAMPLE EXCEED TMCL FREQUENCY
GENERAL ASSUMPTIONS
1) QA SAMPLING CALCULATED BY RACER.
2) FLUFF FACTOR AT 25 PERCENT.
3) CONFIRMATION SAMPLES AT 900 FOOT CENTERS (EXCEPT AS SHOWN).
4) ONE SOIL SAMPLE TAKEN PER NEW WELL, ANALYZED FOR COCs.
5) OFFSITE DISPOSAL OF WASTE ASSUMMED FOR ALL SITES.
IRP Work_3rd MEC_SmplngVolRev(Attch4)Vers2.xlsx 8 of 8
SITE ID PHASE SITE/PARAMETER UNITS AMOUNT COMMENTS
6) ANALYSES SHOWN FOR CONFIRMATION SAMPLES APPLY TO ALL OTHER
SAMPLES UNLESS OTHERWISE INDICATED.
7) BACKFILL INCLUDED WITH EXCAVATION, ROCKFILL DELETED FROM ASSEMBLY
ONSITE SOURCE IS ASSUMED.
8) DISPOSAL SAMPLES ASSUMED AT ONE FOR EVERY 500 CUBIC YARDS.
9) AOCs 23/24 ADDRESSES POTENTIAL SOIL CONTAMINATION UNDERNEATH
EXPLOSIVE FOUNDATIONS AND SEWERS. RIND SOIL HANDLED IN SWMU/AOC.
10) CONFIRMATION SAMPLE FREQUENCY FOR FORMER CONTAMINATED SOIL STOCK-
PILE AREAS SET AT TOTAL CUBIC YARDS OF DISPOSED CONTAMINATED SOIL
CONVERTED TO CUBIC FEET (CY/27=CF), THEN DIVIDE BY 20 (HEIGHT OF
SOIL STOCKPILES) TIMES 900 (SQUARE FEET SAMPLING FREQUENCY)
SUNFLOWER ARMY AMMUNITION PLANT
REMAINING MEC SEWERS
TOTALS BY AREA
Surface 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 20 22 DNA Totals By Diameter
Diameter (Inches)
1/2 115 115 2 320 320 4 2024 52 4490 6566 6 481 321 199 6026 7027 8 1754 98 723 954 63 22904 26496
10 200 269 1428 265 181 1859 4202 12 779 179 864 265 506 3628 6221 15 406 456 328 1190 16 1048 1048 18 409 617 75 185 1286 20 272 272 21 287 192 98 577 24 699 612 4275 5586 27 585 709 1294 30 606 222 324 464 1616 36 562 170 732 42 0 48 80 80 54 0 60 295 295
Metal Trough 197 197
Totals By Depth 197 0 200 6122 277 6638 0 4383 0 1259 0 464 0 0 0 0 0 0 0 45580 65120
GRAND TOTALS SHEET FOR ALL OF SFAAP OUTSIDE MEC SEWERS
Depth (Feet)
REMAINING MEC SEWERS
TOTALS BY AREA
GRAND TOTALS SHEET FOR ALL OF SFAAP OUTSIDE MEC SEWERS
G-Line P-mix
Five Corners NG NQ
South Acid
Tank Farm
Grand Total
Total by Area 5932 3949 1690 1780 2216 4329 19896
REMAINING MEC SEWERS
TOTALS BY AREA
3 4 5 6 7 8 9 10 11 12 13 15
Depths Not
Available Totals By Diameter meter (Inch 4 663 663 6 0 8 85 85
10 0 12 380 783 1163 14 0 15 234 238 472 16 0 18 409 259 668 21 287 287 24 416 171 587 27 585 709 1294 30 117 110 227 36 486 486 42 0 48 0 54 0 otals By Dep 0 1771 0 2685 0 1476 0 0 0 0 0 0 0
Grand Total 5932
G-LINE PRE-MIX AREA TOTALS SHEET
Depths (Feet)
Lengths (Feet)
REMAINING MEC SEWERS
TOTALS BY AREA
2 4 6 8 10 12 15 16 18 20 24 metal trough
Depths Not Available
Totals By Diameter
Diameter (Inches) 4 195 52 247 6 108 108 8 910 150 531 63 1654
10 71 35 106 12 249 81 160 160 650 14 0 15 218 328 546 16 0 18 0 21 0 24 441 441 27 0 30 0 36 0 42 0 48 0 54 0
Totals By Depth 0 1533 536 1460 223 0 0 0 0 0 0 197 0
Grand Total 3949
FIVE CORNERS PASTE MIX AREA TOTALS SHEET
REMAINING MEC SEWERS
TOTALS BY AREA
3 4 5 6 7 8 9 10 11 12 13 15 Depths Not Available
Totals By Diameter
Diameter (Inches) 4 158 158 6 140 140 8 187 187
10 200 198 359 757 12 102 346 448 14 0 15 0 16 0 18 0 21 0 24 0 27 0 30 0 36 0 42 0 48 0 54 0
Totals By Depth 200 683 102 359 0 0 0 346 0 0 0 0 0
Grand Total 1690
NG AREA TOTALS SHEET
REMAINING MEC SEWERS
TOTALS BY AREA
3 4 5 6 7 8 9 10 11 12 13 15 Depths Not Available
Totals By Diameter
Diameter (Inches) 4 0 6 233 198 431 8 376 573 400 1349
10 0 12 0 14 0 15 0 16 0 18 0 21 0 24 0 27 0 30 0 36 0 42 0 48 0 54 0
Totals By Depth 0 609 0 771 0 400 0 0 0 0 0 0 0
Grand Total 1780
NQ AREA TOTALS SHEET
REMAINING MEC SEWERS
TOTALS BY AREA
2 4 6 8 10 12 15 16 18 20 24 30 Depths Not Available
Totals By Diameter
Diameter (Inches) 4 0 6 123 199 322 8 23 23
10 80 265 181 526 12 105 105 14 0 15 0 16 0 18 75 185 260 21 192 192 24 0 27 0 30 324 464 788 36 0 42 0 48 0 54 0
Totals By Depth 0 0 203 859 690 464 0 0 0 0 0 0 0
Grand Total 2216
Lengths (Feet)
SOUTH ACID AREA TOTALS SHEET
REMAINING MEC SEWERS
TOTALS BY AREA
3 4 5 6 7 8 9 10 11 12 13 15 Depths Not Available
Totals By Diameter
Diameter (Inches) 4 924 924 6 0 8 196 98 294
10 954 954 12 150 77 227 14 0 15 172 172 16 0 18 358 358 21 0 24 283 283 27 0 30 489 112 601 36 516 516 42 0 48 0 54 0
Totals By Depth 0 1442 175 2084 0 628 0 0 0 0 0 0 0
Grand Total 4329
SOLVENT TANK FARM NORTH AREA TOTALS SHEET
REMAINING MEC SEWERS
TOTALS BY AREA
G-Line PreMix
Five Corners NG NQ South Acid Tank Farm
Grand Total
Totals 5932 3949 1690 1780 2216 4329 19896 2634 1856 719 1780 1165 3059 1677 2093 971 969 1270 1621 82
Remaining FR1 Foundations
BLDG
NUMBER TITLE FND SWMU or
AOC GRID YEAR
BUILT
FS, PS,
NS
Slabless
AREA
Slabless
MEC
Samples
Concrete Slab Area
Slab MEC Samples
Above GR Wall
SQ FT
Below GR Wall
SQ FT
Total Concrete
SQ FT
Basement /Sump Backfill
Drawing Number Index
6869-1 Paste Dry House FR1 AOC 12 19-G 1945 FS 0 0 2,810 2 2,810 S-46890 602 6869-2 Paste Dry House FR1 AOC 12 19-G 1945 FS 0 0 2,810 2 2,810 S-46890 603 6869-3 Paste Dry House FR1 AOC 12 20-G 1945 FS 0 0 2,810 2 2,810 S-46890 604 6869-4 Paste Dry House FR1 AOC 12 20-G 1945 FS 0 0 2,810 2 2,810 S-46890 605 6869-5 Paste Dry House FR1 AOC 12 21-G 1945 FS 0 0 2,810 2 2,810 S-46890 606 6869-6 Paste Dry House FR1 AOC 12 21-G 1945 FS 0 0 2,810 2 2,810 S-46890 607 6869-7 Paste Dry House FR1 AOC 12 22-G 1945 FS 0 0 2,810 2 2,810 S-46890 608 6869-8 Paste Dry House FR1 AOC 12 21-G 1945 FS 0 0 2,810 2 2,810 S-46890 609 6869-9 Paste Dry House FR1 AOC 12 21-G 1945 FS 0 0 2,810 2 2,810 S-46890 610 6869-10 Paste Dry House FR1 AOC 12 22-G 1945 FS 0 0 2,810 2 2,810 S-46890 611 6869-11 Paste Dry House FR1 AOC 12 21-G 1945 FS 0 0 2,810 2 2,810 S-46890 612 6869-12 Paste Dry House FR1 AOC 12 21-G 1945 FS 0 0 2,810 2 2,810 S-46890 613 6869-13 Paste Dry House FR1 AOC 12 22-G 1945 FS 0 0 2,810 2 2,810 S-46890 614 6869-14 Paste Dry House FR1 AOC 12 21-H 1945 FS 0 0 2,810 2 2,810 S-46890 615 6869-15 Paste Dry House FR1 AOC 12 22-H 1945 FS 0 0 2,810 2 2,810 S-46890 616 6869-16 Paste Dry House FR1 AOC 12 22-H 1945 FS 0 0 2,810 2 2,810 S-46890 617
AOC 12 Total Concrete Slab Area 44,960
2019 Boiling Tub House FR1 AOC 16 FS 0 0 32605* 14* 3341* 0 1,131 S-36615;7285-A-419; 7285-6-
241 279 C2013 Fume Stack FR1 AOC 16 FS 0 0 903 1 903 7285-5-760 317 2022 Beater House FR1 AOC 16 FS 0 0 7132* 3* 6* 0 1 7285-6-241; S-36420 282
2024 Poacher and Blender House FR1 AOC 16 FS 0 0 37168* 15* 480* 0 1 7285-6-241; S-36481; 7285-A-
602 284 C3013 Fume Stack FR1 AOC 16 FS 0 0 903 1* 903 7285-5-760 317
3019 Boiling Tub House FR1 AOC 16 FS 0 0 32,605 14* 3,341 35,946 1,131 7285-6-241;7285-A-419;S-
36615 319 3022 Beater House FR1 AOC 16 FS 0 0 7132* 3* 6* 0 1 7285-6-241; S-36420 322
3024 Poacher and Blending House FR1 AOC 16 FS 0 0 36774* 15* 60* 0 2 7285-6-241;7285-A-617;S-
36481 324 C4013 Fume Stack FR1 AOC 16 12-F 1943 FS 0 0 903 1 903 7285-5-760 363
4019 Boiling Tub House FR1 AOC 16 1943 FS 0 0 25237* 11* 3311* 0 1,133 7285-6-241;S-36615;S-36781 365 4022 Beater House FR1 AOC 16 1943 FS 0 0 7132* 3* 6* 0 1 7285-6-241; S-36420 368 4024 Poacher & Blending House FR1 AOC 16 1943 FS 0 0 29500* 12* 60* 0 2 7285-6-241;S-36481 370
5019 Boiling Tub House FR1 AOC 16 1943 FS 0 0 29,607 12 4,928 34,535 1,683 7285-6-226;S-42551;S-
42722;S-36615 401 5022 Beater House FR1 AOC 16 1943 FS 0 0 7132* 3* 6* 0 1 7285-6-226;S36420 404 5024 Poacher & Blending House FR1 AOC 16 1943 FS 0 0 41,239 17 90 41,329 3 7285-6-226; S-42656 406 5026-2 Final Wringer House FR1 AOC 16 1943 FS 0 0 4189* 2* 8* 0 1 S-42701; SOW 1688 409 5046 Beater House FR1 AOC 16 1943 FS 0 0 7132* 3* 6* 0 1 7285-6-241; S-42707 411 5047 Blender House FR1 AOC 16 1943 FS 0 0 11,327 5 60 11,387 7285-6-241;S-45914 413
AOC 16 TBPs Total Concrete Slab Area 117,487 Concrete Already Removed at Wet NC Accts " * "
904 Sulphuric Acid Concentrator FR1 AOC 17 9-N 1979 FS 0 0 3,845 2 80 3,925 4 SFAAP 13019 72 C904 Weak Acid Storage Tank FR1 AOC 17 9-N 1979 PS 1,225 1 45 1 55 100 3 SFAAP 15738 73 D904 Weak Acid Storage Tank FR1 AOC 17 9-N 1979 PS 1,225 1 45 1 55 100 3 SFAAP 15738 74 E904 Stage 1 Distillate Tank FR1 AOC 17 9-N 1979 PS 1,225 1 45 1 55 100 3 SFAAP 15738 75
Remaining FR1 Foundations
BLDG
NUMBER TITLE FND SWMU or
AOC GRID YEAR
BUILT
FS, PS,
NS
Slabless
AREA
Slabless
MEC
Samples
Concrete Slab Area
Slab MEC Samples
Above GR Wall
SQ FT
Below GR Wall
SQ FT
Total Concrete
SQ FT
Basement /Sump Backfill
Drawing Number Index
F904 Stage 2 Distillate Tank FR1 AOC 17 9-N 1979 PS 441 1 48 1 56 104 3 SFAAP 15737 76 G904 Stage 3 Distillate Tank FR1 AOC 17 9-N 1979 PS 441 1 48 1 56 104 3 SFAAP 15737 77 H904 #1 Product Acid Storage Tank FR1 AOC 17 9-N 1979 PS 324 1 41 1 51 92 3 SFAAP 15736 78 I904 #2 Product Acid Storage Tank FR1 AOC 17 9-N 1979 PS 324 1 41 1 51 92 3 SFAAP 15736 79 J904 Caustic Storage Tank FR1 AOC 17 9-N 1979 PS 110 1 16 1 16 SFAAP 13080 80 K904 NQ Waste Water Treatment Tank FR1 AOC 17 9-N 1979 FS 0 0 424 1 56 480 Field Measurement 81 L904 Lime Slurry Tank FR1 AOC 17 9-N 1979 FS 0 0 185 1 51 236 SFAAP 20678 82 M904 Lime Storage Silo and Slaker Tank FR1 AOC 17 9-N FS 0 0 276 1 276 SFAAP 20678 83
A927 Sump (Explosive) FR1 AOC 17 9-N 1977 FS 0 0 497 1 1,005 1,502 29 SFAAP 18037; Outside
Trenches 927 86
B927 Sump (Acid) FR1 AOC 17 9-N 1977 FS 0 0 276 1 564 840 17 SFAAP 18037; Outside
Trenches 927 87
A928-3 Scrubber, Conveyor Dryer Vacuum FR1 AOC 17 10-M FS 0 0 591 1 2,112 401 3,104 15 SFAAP 15689; Outside Trenches 9041 & 928-3 88
A928-4 Scrubber, Conveyor Dryer Vacuum FR1 AOC 17 10-L 1979 FS 0 0 588 1 2,112 395 3,095 15 SFAAP 15696; Outside
Trenches 928-4 89 928-5 Conveyor H 585 FR1 AOC 17 10-O 1979 NS 7,028 3 0 0 SFAAP 17066 90
A928-5 Scrubber, Conveyor Dryer Vacuum FR1 AOC 17 10-O 1979 FS 0 0 579 1 2,112 377 3,068 14 SFAAP 15703; Outside
Trenches 928-5 91 9015 Guanidine Rest House FR1 AOC 17 10-M 1978 FS 0 0 388 1 388 SFAAP 15232 629 9017 Pack House FR1 AOC 17 10-O 1978 FS 0 0 3,754 2 738 4,492 21 SFAAP 15587 630 A9017 Dry Vacuum Scrubber FR1 AOC 17 10-O 1978 FS 0 0 389 1 2,286 399 3,074 10 SFAAP 15593 631 B9017 Dust Collector Scrubber FR1 AOC 17 10-N 1978 FS 0 0 295 1 1,092 190 1,577 5 SFAAP 15597 632
C9031 Sulfuric Acid Storage Tank FR1 AOC 17 9-N 1986 NS 70 1 0 SFAAP 14812; Field
Measurement 633
9040 Wet Guanidine Nitrate FR1 AOC 17 9-L 1979 FS 0 0 9,591 4 1,682 11,273 63 SFAAP 14956; 14957; 14958 634
F9040 Decanters FR1 AOC 17 9-L 1987 FS 0 0 7,785 4 7,785 SFAAP 17121; Field
Measurement 635
9041 Dry Guanidine Nitrate FR1 AOC 17 10-M 1978 FS 0 0 5,432 3 669 6,101 19 SFAAP 15131; 15132; Outside
Trenches 9041 & 928-3 636 A9041 Dryer Vapor Scrubber FR1 AOC 17 10-M 1978 FS 0 0 806 1 3,945 198 4,949 6 SFAAP 15136 637 B9041 Dust Collector Scrubber FR1 AOC 17 10-M 1978 FS 0 0 520 1 973 379 1,872 8 SFAAP 15140 638 H9041 North Mother Liquor Surge Tank FR1 AOC 17 10-M FS 0 0 441 1 441 SK-SFAAP 7282 639
9042 Wet Nitroguanidine FR1 AOC 17 10-N 1979 FS 0 0 12,728 6 2,828 15,556 79
SFAAP
15289;15290;15291;15292 640 E9042 Recovered SA Storage Tank FR1 AOC 17 10-N 1979 FS 0 0 314 1 314 SFAAP 15294 641
H9042 Oleum Nitric Acid Storage FR1 AOC 17 10-N PS 513 1 580 1 580 SFAAP 20347; Field
Measurement 642
9043 Dry Nitroguanidine FR1 AOC 17 10-O 1978 FS 0 0 6,772 3 1,456 8,228 43 SFAAP 15477; 15478; Outside
Trenches 9043 643 A9043 Dryer Vent Scrubber FR1 AOC 17 10-O 1978 FS 0 0 1,848 1 5,102 795 7,745 22 SFAAP 15482 644 B9043 Dust Collector FR1 AOC 17 10-O 1978 FS 0 0 533 1 2,101 308 2,942 9 SFAAP 15487 645
AOC 17 Total Concrete Slab Area 59,766 113-11 Unloading Station FR1 SWMU 24 19-H NS 65 1 0 0 SFAAP 17823 2 113-20 Unloading Station (Glyc) FR1 SWMU 24 19-H 1942 NS 65 1 0 0 SFAAP 17823 4 554-8 Area Oil House N.G. Area FR1 SWMU 24 1951 NS 108 1 0 0 SOW 4920 39
Remaining FR1 Foundations
BLDG
NUMBER TITLE FND SWMU or
AOC GRID YEAR
BUILT
FS, PS,
NS
Slabless
AREA
Slabless
MEC
Samples
Concrete Slab Area
Slab MEC Samples
Above GR Wall
SQ FT
Below GR Wall
SQ FT
Total Concrete
SQ FT
Basement /Sump Backfill
Drawing Number Index
600-6 Solvent Storage (4 Tanks) FR1 SWMU 24 19-H 1943 FS 0 0 2,057 1 2,057 7285-5-779 53 A600-6 Pump House FR1 SWMU 24 19-H FS 0 0 186 1 94 280 SOW 3951 54 926 Slurry Analysis House FR1 SWMU 24 18-G 1976 FS 0 0 263 1 897 1,160 SAAP 12208 84 A926 Building Sump #5 FR1 SWMU 24 18-G FS 0 0 24 1 152 176 9 SAAP 9827 85 5653 GlycerineTanks & Storage House FR1 SWMU 24 19-H 1943 NS 2,166 1 0 0 S-39374 422 A5653 Pump House FR1 SWMU 24 19-H FS 0 0 120 1 120 S-39376 423
5654 NG Emulsion Transfer System FR1 SWMU 24 19-I NS 4654 L 10 0 0
SAAP
10042;10046;10095;10096 424 5655-1 Mixed Acid Storage & Weigh House FR1 SWMU 24 1943 PS 680 1 560 1 560 S-39323 425 5655-2 N.G. Mixed Acid Storage & Weigh House FR1 SWMU 24 1943 PS 224 1 340 1 340 S-39397 426 5655-3 Mixed Acid Tanks FR1 SWMU 24 1943 NS 760 1 0 0 SAAP 10073 427 5656-1 Glycerine Tank (Heated) FR1 SWMU 24 1943 NS 132 1 0 0 S-39378 428 A5656-1 Pump House FR1 SWMU 24 FS 0 0 120 1 120 S-39378 429 5656-2 Glycerine Tank (Heated) FR1 SWMU 24 1943 NS 132 1 0 0 S-39403 430 A5656-2 Pump House FR1 SWMU 24 FS 0 0 120 1 120 S-39403 431 5657-1 N.G. Nitrating & Separating House FR1 SWMU 24 1943 PS 385 1 583 1 583 S-39305 432 A5657-1 Soda Ash Store House FR1 SWMU 24 NS 120 1 0 0 S-39372 433 B5657-1 Catch Tank House FR1 SWMU 24 FS 0 0 120 1 120 S-39343 434 5657-2 N.G. Nitrating & Separating House FR1 SWMU 24 1943 PS 385 1 583 1 583 S39305 435 A5657-2 Soda Ash Store House FR1 SWMU 24 NS 120 1 0 0 S-39372 436 B5657-2 Catch Tank House FR1 SWMU 24 FS 0 0 120 1 120 S-39343 437 5657-3 N.G.