TYPICAL SINGLE CANTILEVERED SLIDING GATE ELEVATION- (4) BAYS SHOWN

A4

SECTION (TYP) A4

GATE PLAN C1

A1

A1

UFC-703

C H

A

IN

L

IN

K C

A N

TI

LE

V E

R E

D G

A

TE

D E

TA

IL

S

AutoCAD SHX Text

POST TOP

AutoCAD SHX Text

PROVIDE CONCRETE FOOTING (*)

AutoCAD SHX Text

1'-1" [330MM]

AutoCAD SHX Text

TRUSS ROD

AutoCAD SHX Text

KEEPER

AutoCAD SHX Text

CHAIN LINK FABRIC

AutoCAD SHX Text

TO OPEN

AutoCAD SHX Text

ONLY

AutoCAD SHX Text

LOWER

AutoCAD SHX Text

UPRIGHTS

AutoCAD SHX Text

INTERIOR

AutoCAD SHX Text 12'-0"

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text 30'-0"

AutoCAD SHX Text 42'-3"

AutoCAD SHX Text

WITH ROUND POSTS & WITH BARBED WIRE

AutoCAD SHX Text

4 (FABRIC) / 2 (W/O)

AutoCAD SHX Text

TRACK / RAIL

AutoCAD SHX Text

2" SQ UPRIGHT

AutoCAD SHX Text 2" x 4" RAIL

AutoCAD SHX Text

2" SQ STIFFENER

AutoCAD SHX Text

GUIDE ROLLER ASSEMBLY

AutoCAD SHX Text

CHAIN LINK FABRIC

AutoCAD SHX Text

TENSION ROD

AutoCAD SHX Text

FRAME HT

AutoCAD SHX Text

(OMIT FABRIC)

AutoCAD SHX Text

3" [76MM] NOMINAL

AutoCAD SHX Text

TRUSS ROD

AutoCAD SHX Text

TRACK

AutoCAD SHX Text

TRUCK ASSEMBLY

AutoCAD SHX Text

WELDED JOINT

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text CABLE REINFORCING (IF REQUIRED). PROVIDE TWIST-OFF METAL TIES TO SECURE CABLE TO FABRIC @ 24" OC & U-BOLTS TO SECURE TO UPRIGHTS.

AutoCAD SHX Text

TENSION ROD

AutoCAD SHX Text 2" x 4" BOTTOM RAIL

AutoCAD SHX Text

(3) STRANDS OF BARBED WIRE, EA CONSISTING OF 2 STRAND LINE WIRE W/ 4 PT BARBS

AutoCAD SHX Text

2" [50MM] SQ UPRIGHT

AutoCAD SHX Text EXTEND CABLE (IF REQ'D) BEYOND OVERHANG AND WRAP/TERMINATE AROUND FENCE REINF (TYP)

AutoCAD SHX Text

FENCELINE

AutoCAD SHX Text

UFC703

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

UFC-703

AutoCAD SHX Text

UFC-703

AutoCAD SHX Text

F/F = INTERIOR FACE TO INTERIOR FACE

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text 8'-0"

AutoCAD SHX Text

NOMINAL HEIGHT (H)

AutoCAD SHX Text 37'-0"

AutoCAD SHX Text 24'-0"

AutoCAD SHX Text

OPENING (F/F)

AutoCAD SHX Text 12'-0"

AutoCAD SHX Text 16'-0"

AutoCAD SHX Text

GATE POSTS (G)

AutoCAD SHX Text 53'-3"

AutoCAD SHX Text 36'-3"

AutoCAD SHX Text

LENGTH (L)

AutoCAD SHX Text

5 (FABRIC) / 2 (W/O)

AutoCAD SHX Text

3 (FABRIC) / 2 (W/O)

AutoCAD SHX Text

BAYS / OVERHANG

AutoCAD SHX Text

OUTSIDE FACE TO OUTSIDE FACE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

CIVIL DWGS

AutoCAD SHX Text

UFC-703

AutoCAD SHX Text

UFC-703

AutoCAD SHX Text

UFC-703

AutoCAD SHX Text

SAMPLING OF SIZES:

AutoCAD SHX Text (*) POST SIZE AND ASSOCIATED FOOTING DIAMETER TO BE DETERMINED BY MANUFACTURER, BASED ON LEAF WEIGHT & DIMENSION. MINIMUM FOOTING DIAMETERS (TO BE FILLED W/4000 PSI CONC): 40" FOR 8" POST; 36" FOR 6" POST; 24" FOR 4" POST; OTHER SIZES TO BEDESIGNED BY MFR OR KTR. NO FOOTING WIDTH SHALL BE LESS THAN 4(X) THE POST WIDTH.

AutoCAD SHX Text

2" [50MM] SQ UPRIGHT

AutoCAD SHX Text

2" SQ UPRIGHT

AutoCAD SHX Text

2" [50MM] SQ UPRIGHT

AutoCAD SHX Text

2" [50MM] SQ UPRIGHT

AutoCAD SHX Text

4" [102MM] MIN POST (*) (TYP)

AutoCAD SHX Text

4" MIN POST (*)(TYP)

AutoCAD SHX Text

POST

AutoCAD SHX Text

TOPS

AutoCAD SHX Text

DOMED

AutoCAD SHX Text

EXOTHERMIC WELD

AutoCAD SHX Text

EXOTHERMIC WELD

AutoCAD SHX Text 34"x10' GROUND ROD

AutoCAD SHX Text 34"x10' GROUND ROD

AutoCAD SHX Text

10 BARE COPPER

AutoCAD SHX Text

10 BARE COPPER

AutoCAD SHX Text

50' GROUND REEL, ERICO, B2618B

AutoCAD SHX Text

GATE OPERATOR

AutoCAD SHX Text

ROLL CHAIN

AutoCAD SHX Text

GATE OPERATOR

AutoCAD SHX Text NOTE: BARBED WIRE NOT SHOWN ON FENCE PORTION FOR CLARITY. SEE SHEET UFC S-701 FOR BARBED WIRE TYPE.

AutoCAD SHX Text Xref J:\CICE\FENCE DRAWINGS\UFC_BORDER.dwg

AutoCAD SHX Text

UFC-703

Sheets and Views
552005-UFC-703-Layout1
22x34
34x22