This document contains a technical exhibit and pre-solicitation notice for a fire prevention and protection system maintenance and repair contract. The technical exhibit provides an inventory of 357 fire alarm systems located at Fort Buchanan in Puerto Rico, listing the building number, panel brand and model, and device details for each system. The pre-solicitation notice indicates the Mission and Installation Contracting Command at Fort Buchanan will issue a firm-fixed price solicitation for preventive maintenance of fire alarm and sprinkler systems at Fort Buchanan. Interested vendors must register in the System for Award Management and regularly check for the solicitation and any amendments on the Contracting Opportunities website after January 15, 2019. The work will be a 100% small business set-aside under NAICS code 561621 with a size standard of $22 million. The point of contacts are provided for any questions.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Amendment 0005.pdf | ||
| Amend4_Sol_W912C320R0003_FireProtectionPM_20200715.pdf | ||
| Attachment 3 SUBCLIN STRUCTURE REPAIR PARTS (REV1).docx | DOCX document | |
| Amend3_Sol_W912C320R0003_FireProtectionPM_20200701.pdf | ||
| Amend 0002_Extended W912C320R0003_FireProtectionPM_20200619.pdf | ||
| Solicitation-W912C320R0003_FireProtectionPM_20200522.pdf | ||
| Amend1_Sol_W912C320R0003_FireProtectionPM_20200526.pdf | ||
| Attachment 3 SUBCLIN STRUCTURE REPAIR PARTS.docx | DOCX document | |
| Solicitation W912C320R0003_Fire Protection PM_20200522.pdf | ||
| Technical Exhibit 7 - FPS Report_Rev Mar 2020.pdf | ||
| Attachment 2 Fire Protection and Notification Systems Photos.pdf | ||
| Technical Exhibit 8 - Facilities Manager List.pdf | ||
| Attachment 1 Wage Determination 15-5707 Rev.12.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
TECHNICAL EXHIBIT 6 – FIRE ALARM INVENTORY REV. AUG 2019
1 21 X Fire-Lite (MS-9200) X 4 MP 8 SMK 2 DD 1 WT 2 TS
New DPW 14 MP 22 SMK 4 DD 3 WF 3 TS
(34, 37 &
38) X Simens
4MP 1SD
3 X
32 MP 67 SMK
73-74-75-
77-78 X
5 136 X 4 MP 11 SMK 1 HD
6 148 X
7 151 X 3 MP 6 SMK
4 MP 9 SMK
8 152 X
3 MP 5MK 1 DD 2HD
9 161 X
2 MP 1 WF
10 167 X
3 MP 5 HD 1 DD 1 WF 1 TS 2HD
11 168 X
3 MP 2 SMK 2HD
12 172 X
5 MP 7 SMK 1 DD 3 HD
13 183 X
2 MP 11 SMK 1 DD
14 192 X
2 MP 8 SMK
15 193 X
3 MP 9 SMK
16 202 X
2 MP 6 SMK
17 203 X
2 MP 22 SMK 1 DD
18 204 X
2 MP 15 SMK 1 DD
19 214 X
3 MP 15 SMK 1 DD
20 223 X
3 MP 14 SMK 1 DD
21 224 X
4 MP 12 SMK 1 DD
22 225 X
3 MP 10 SMK 1 DD
23 227 X
3 MP 18 SMK 1 DD
24 228 X HONEYWELL(VISTA128FB)
2 MP 8 SMK 1 DD
25 231 X
2 MP 15 SMK 1 DD
26 233 X
3 MP 4 SMK
27 292 X FIRE LITE
2 MP 9 SMK 1 DD
28 295 X FIRE LITE (MS-2)
NOTIFIER 18 MP 14 SMK 11 DD 1 WF 1 TS 3 HD
X (NFS2‐3030‐ ONYX Series)
6 MP 8 SMK 1 DD 1 WF 1 TS
30 353 X Fire-Lite (MS-9600)
31 354 X 6 MP 8 SMK 1 DD 1 WF 1 TS
32 355 X 4 MP 5 SMK 1 DD 1 WF 1 TS
33 356 NA
34 357 X 4 MP 5 SMK 1 DD 1 WF 1 TS
9 MP 19 SMK 1 WF 1TS
Smoke Detectors
Pull Stations Duct
Detetctors
Water Flow
Switch Tamper Switch
Heat Detectors
X
X
X
X
X
X
X
X
X
X
X
X
Addressable
X
X
HYBRID (ARE
ADDRESSABLE PANELS
WITH MODULES TO
READ ANALOG
X
X
X
X
X
X
X
X
X
Analog
X
X
X
X
X
Fire-Lite (MS-9600)
Fire-Lite (MS-9600)
All Raiser- No fire Alarm/Attached to
355 PNL
RADIONICS(8024)
SIMPLEX
X
X
RADIONICS(8024) X
RADIONICS(8024)
RADIONICS(8024)
X
X
Fire-Lite (MS-9600)
FacilityItem Propietary Systems
X
X
(New
NAVY)
Fire-Lite (MS-9200)
Fire-Lite (MS-50UD)
Edward (EST-3)
Fire-Lite (ECC-50/100)
X
Fire Alarm System
EDWARD (LSS4)
FIRST ALERT (1600FB)
Fire-Lite (MS-9200UDLS)
Fire-Lite (MS-4)
Fire-Lite (MS-4)
Fire-Lite (MS-9050UD)
Fire-Lite (MS-9200UDLS)
Fire-Lite (MS-9200)
RADIONICS(8024)
RADIONICS(8024)
FIRST ALERT
RADIONICS(8024)
HONEYWELL(VISTA128FB)
HONEYWELL(VISTA128FB)
X
X
X
X
X
Fire Alarm Panel Brand and Model
X
29 315
X
X
X
X
X
35 376 X
3 MP 10 SMK 1 WF 1 TS 2 HD
36 379 X
37 390 X 14 MP 127 SMK 3 DD 1 HD
38 399 X
39 507 X 2MP 1 SMK 1 WF
40 509 X 1 WF
(Only
Communic ator)
10 MP 45 SMK 1 WF
41 511 X
42 512 X
43 514 X 1 MP 2 SMK 1 WF
44 518 X
45 519 X
1 WF
46 523 X
2 MP 2 SMK 1 WF
47 527 X
7 MP 27 SMK 1 DD 1 HD
48 528 X
49 540 X EDWARD (QS-4)
50 545 X 5MP 8 SMK
51 546 X 11MP 8 SMK
52 547 X 14MP 8 SMK
53 548 X 4MP 2 SMK
54 550 X 6MP 4 SMK
55 552 X
6MP 4 SMK
4 MP 61 SMK
56 566 X
9 MP 5 SMK 8 DD
57 606 X
9 MP 34 SMK 8 DD 2 WF 2 TS
58 607 X
8 MP 26 SMK 1 WF 1 TS
59 608 X
SILENT ) 5 MP 8 SMK 1 DD 1WF 1 TS
60 609 X SILENT NIGHT(5820XL)
2 MP 10 SMK 1 WF 1 TS
61 611 X
8 MP 34 SMK 1 WF 1 TS
62 612 X
11 MP 44 SMK 1 WF 1 TS
63 613 X
8 MP 34 SMK 1 WF 1TS
64 614 X
NOTIFIER 10 MP 2 SMK 1 WF 1TS
65 X (NFS2-3030- ONYX Series)
6 MP 4 SMK 1 WF 1TS 27 HD
66 660 X
5MP 51 SMK 1 WF 1 TS 1 HD
1DD
3 MP 13 SMK 1DD
13 MP 123 SMK 2 DD
1 MP 2 SMK 1 DD 1 WF
3 MP 13 SMK
X
X
X (PNL)
X (PNL)
X(EQP)
X(EQP)
X
X
X
X
X
X
X
X
X
X (PNL) X(EQP)
NO
NO
X NO
X (PNL) X(EQP)
X
X
X
X
X
NO
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
EDWARD(LSS4)
CERBERIUS PYROTRONICS(XL)
HONEYWELL (VISTA128FB)
CERBERIUS PYROTRONICS(XL)
Fire-Lite (MS-9200UDLS)
CERBERIUS PYROTRONICS(XL)
RADIONICS(8024)
Fire-Lite (MS-9200UDLS)
Fire-Lite (MS-9200)
NOTIFIER(SYSTEM 5000)
CERBERIUS PYROTRONICS(XL)
RADIONICS(8024)
FIRE-LITE (FS-50)- Yr 2019
Fire-Lite (MS-9600)
NOTIFIER(NFW-50)
COMUNICAITOR ONLY- For Flow switch
RADIONICS(8024)
COMUNICAITOR ONLY- For Flow switch
X
HONEYWELL(VISTA128FB)
Fire-Lite (FS-9600UDLS)-2019
XEDWARD(QS-4)
Fire-Lite (MS-9200)
X
X
X
Fire-Lite (MS-9600)
Siemens
Siemens
Siemens
Siemens
Siemens
Siemens
Smoke Detectors
Pull Stations Duct
Detetctors
Water Flow
Switch Tamper Switch
Heat Detectors
Addressable
HYBRID (ARE
ADDRESSABLE PANELS
WITH MODULES TO
READ ANALOG
AnalogFacilityItem Propietary Systems
Fire Alarm System
Fire Alarm Panel Brand and Model
Community Club
Exterior Kitchen
X
2 MP 13 SMK
68 673 X
3 MP 9 SMK
69 676 X
4 MP 7 SMK
70 677 X
12 MP 20 SMK 2 DD 3 WF 3 TS
AAFES
X
CERBERIUS PIROTRONICS (IXL) 12 MP 20 SMK 6 DD 3 WF 3 TS
72 689 DECA X NEW VERSION
700 (New Elementary
School)
AES
X
35 MP 55 SMK
1100 (New
CDC)
X
25MP 112 SMK
7 MP 29 SMK
75 1321 X
76 X
31 MP 63 DD(ADRESSABLE ) 9 WF
77 X 15 DD (CONVENCIONAL)
78 X
28 MP 18 SMK 7 DD
X
X
X
X NO
X
X
X
X
X
X
XEDWARD (LSS4/12)
EDWARD(EST3)
Gamewell
FIRST ALERT (1600FB)
GAMEWELL S3(7100)
GAMEWELL S3
Fire-Lite (MS-9200UDLS)
Fire-Lite (MS-5024UDL)
Simens( IXL)
CERBERIUS PIROTRONICS (IXL)
X
X
X
X
X
X
AMS
AHS
X
Old AES
Fire Lite MS-9050UD
File details come from the government source that posted it. Updated .