W912BV-15-R-0093_DWGS_1.pdf

PDF 41 MB Posted

Attached to
Plating Shop Renovation, Building 3001, Tinker Air Force Base, Oklahoma.
Solicitation number
W912BV-15-R-0093
Issued by

About this file

Drawings 1

View the file

Other files

File Type Posted
W912BV-15-R-0093-0006.pdf PDF
W912BV-15-R-0093-0005.pdf PDF
W912BV-15-R-0093-0004.pdf PDF
W912BV-15-R-0093-0003a.pdf PDF
W912BV-15-D-0093-0002.pdf PDF
Site_Visit_Attendee_Sheet.pdf PDF
W912BV-15-D-0093-0001.pdf PDF
W912BV-15-R-0093_DWGS_8.pdf PDF
W912BV-15-R-0093_DWGS_2.pdf PDF
W912BV-15-R-0093_DWGS_6.pdf PDF
W912BV-15-R-0093_DWGS_4.pdf PDF
W912BV-15-R-0093_DWGS_3.pdf PDF
W912BV-15-R-0093_DWGS_5.pdf PDF
W912BV-15-R-0093_DWGS_7.pdf PDF
W912BV-15-R-0093_SPECSa.pdf PDF
Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

5 4 3 2 1

12345

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

Tulsa District

TINKER AIR FORCE BASE, OKLAHOMA

US Army Corps Of Engineers

Tulsa, OKLAHOMA

CIVIL, ARCHITECTURAL, STRUCTURAL, ELECTRICAL, FIRE ALARM & FIRE PROTECTION

SOLICITATION NO.: W912BV-15-R-0093

CONTRACT NO.:

WWYK150110 - REPLACE ROOF OVER PLATING SHOP AREA

SET 1 OF 8

8/21/2015

78794-A-1000

0 LEGENDS

1 PLANS

2 P&IDS

3 SECTIONS

4 ENLARGED PLANS

5 DETAILS

6 SCHEDULES/DIAGRAMS

7 USED DEFINED

8 USER DEFINED

9 USER DEFINED

PROJECT NUMBER

SHEET FILE NAMING CONVENTION

SHEET DESIGNATOR

A - ARCHITECTURAL

AD - ARCHITECTURAL DEMOLITION

C - CIVIL

E - ELECTRICAL

ED - ELECTRICAL DEMOLITION

EP - ELECTRICAL POWER

EL - ELECTRICAL LIGHTING

EI - ELECTRICAL INSTRUMENTAION

FA - FIRE ALARM

FX - FIRE PROTECTION

G - GENERAL

LS - LIFE SAFETY

SD - STRUCTURAL DEMOLITION

M - MECHANICAL

MD - MECHANICAL DEMOLITION

MH - MECHANICAL HVAC

MP - MECHANICAL PIPING

MQ - MECHANICAL EQUIPMENT

S - STRUCTURAL

SD - STRUCTURAL DEMOLITION

AREA NUMBER*

0 OVERALL PLAN*

1 AREA A

2 AREA B

3 AREA C

4 AREA D

5 AREA E

6 AREA F

7 AREA G

8 AREA H

LEVEL*

0 BASEMENT

1 OPERATING FLOOR

2 MEZZANINE

3 BOTTOM CHORD FRAMING

4 ROOF

5 ROOF PLATFORM

PHASE NUMBER

0 MASTER SET

1 PHASE 1

2 PHASE 2

3 PHASE 3

4 PHASE 4

5 PHASE 5

6 PHASE 6

* LEVEL - PLAN SHEETS ONLY

* AREA - PLAN SHEETS ONLY

* OVERALL - ELECTRICAL OVERALL SHEETS THIS EQUALS SEQUENCE NUMBER

SHEET SERIES

5 4 3 2 1

12345

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

GENERAL SHEET INDEX

SHEET NUMBER SHEET TITLE

G-0005 GENERAL PHASING NOTES

CIVIL SHEET INDEX

SHEET NUMBER SHEET TITLE

C-0001 ACCESS AND SAFETY PLAN

C-0002 STAGING AND LAYDOWN AREA PLAN

ARCHITECTURAL SHEET INDEX

SHEET NUMBER SHEET TITLE

AD0100 OVERALL DEMOLITION PLAN - BASEMENT

AD0110 OVERALL DEMOLITION PLAN - OPERATING FLOOR

AD0140 OVERALL DEMOLITION PLAN - ROOF

LS-011 LIFE SAFETY PLAN - BASEMENT

LS-012 LIFE SAFETY PLAN - OPERATING FLOOR

LS-013 LIFE SAFETY PLAN - MEZZANINE

A-0100 OVERALL PLAN - BASEMENT

A-0110 OVERALL PLAN - OPERATING FLOOR

A-0112 AREA PLAN - OPERATING FLOOR - AREA B

A-0114 AREA PLAN - OPERATING FLOOR - AREA F

A-0120 OVERALL PLAN - MEZZANINE

A-0140 OVERALL PLAN - ROOF

A-0400 STAIR PLANS AND SECTIONS

A-0500 ROOF & PENETRATION DETAILS

A-0600 SCHEDULES

STRUCTURAL SHEET INDEX

SHEET NUMBER SHEET TITLE

S-0001 GENERAL NOTES, LEGEND & ABBREVIATIONS

S-0002 STATEMENT OF SPECIAL INSPECTIONS

S-0003 TYPICAL DETAILS

SD0100 DEMOLITION PLAN BASEMENT OVERALL

SD0110 DEMOLITION PLAN OPERATING FLOOR OVERALL

SD0120 DEMOLITION PLAN MEZZANINE OVERALL

SD0130 DEMOLITION PLAN BOTTOM CHORD OVERALL

SD0140 DEMOLITION PLAN ROOF OVERALL

SD0150 DEMOLITION PLAN ROOF PLATFORM OVERALL

SD1106 PHASE 1 DEMOLITION PLAN BASEMENT AREA F

SD1111 PHASE 1 DEMOLITION PLAN OPERATING FLOOR AREA A

SD1116 PHASE 1 DEMOLITION PLAN OPERATING FLOOR AREA F

SD1126 PHASE 1 DEMOLITION PLAN MEZZANINE AREA F

SD2103 PHASE 2 DEMOLITION PLAN BASEMENT AREA C/D

SD2113 PHASE 2 DEMOLITION PLAN OPERATING FLOOR AREA C/D

SD2153 PHASE 2 DEMOLITION PLAN ROOF PLATFORM AREA C/D

SD3107 PHASE 3 DEMOLITION PLAN BASEMENT AREA G/H

SD3117 PHASE 3 DEMOLITION PLAN OPERATING FLOOR AREA G/H

SD3127 PHASE 3 DEMOLITION PLAN MEZZANINE AREA G/H

SD3137 PHASE 3 DEMOLITION PLAN BOTTOM CHORD AREA G/H

SD3157 PHASE 3 DEMOLITION PLAN ROOF PLATFORM AREA G/H

SD4105 PHASE 4 DEMOLITION PLAN BASEMENT AREA E

SD4115 PHASE 4 DEMOLITION PLAN OPERATING FLOOR AREA E

SD4155 PHASE 4 DEMOLITION PLAN ROOF PLATFORM AREA E

SD5102 PHASE 5 DEMOLITION PLAN BASEMENT AREA B

SD5112 PHASE 5 DEMOLITION PLAN OPERATING FLOOR AREA B

SD5122 PHASE 5 DEMOLITION PLAN MEZZANINE AREA B

SD5142 PHASE 5 DEMOLITION PLAN ROOF AREA B

SD5152 PHASE 5 DEMOLITION PLAN ROOF PLATFORM AREA B

S-0100 FOUNDATION PLAN BASEMENT OVERALL

S-0102 FOUNDATION PLAN BASEMENT AREA B

S-0103 FOUNDATION PLAN BASEMENT AREA C/D

S-0105 FOUNDATION PLAN BASEMENT AREA E

S-0106 FOUNDATION PLAN BASEMENT AREA F

S-0107 FOUNDATION PLAN BASEMENT AREA G/H

S-0110 FRAMING AND SLAB PLAN OPERATING FLOOR OVERALL

S-0111 FLOOR SLAB PLAN OPERATING FLOOR AREA A

S-0112 FRAMING AND SLAB PLAN OPERATING FLOOR AREA B

S-0113 FRAMING AND SLAB PLAN OPERATING FLOOR AREA C/D

S-0115 FRAMING AND SLAB PLAN OPERATING FLOOR AREA E

S-0116 FRAMING AND SLAB PLAN OPERATING FLOOR AREA F

S-0117 FRAMING AND SLAB PLAN OPERATING FLOOR AREA G/H

S-0120 FRAMING PLAN MEZZANINE OVERALL

S-0122 FRAMING PLAN MEZZANINE AREA B

S-0123 FRAMING PLAN MEZZANINE AREA C/D

S-0125 FRAMING PLAN MEZZANINE AREA E

S-0127 FRAMING PLAN MEZZANINE AREA G/H

S-0130 FRAMING PLAN BOTTOM CHORD OVERALL

S-0132 FRAMING PLAN BOTTOM CHORD AREA B

S-0133 FRAMING PLAN BOTTOM CHORD AREA C/D

S-0135 FRAMING PLAN BOTTOM CHORD AREA E

S-0136 FRAMING PLAN BOTTOM CHORD AREA F

S-0137 FRAMING PLAN BOTTOM CHORD AREA G/H

S-0140 FRAMING PLAN ROOF OVERALL

S-0141 FRAMING PLAN ROOF AREA A

S-0142 FRAMING PLAN ROOF AREA B

S-0143 FRAMING PLAN ROOF AREA C/D

S-0145 FRAMING PLAN ROOF AREA E

S-0146 FRAMING PLAN ROOF AREA F

S-0147 FRAMING PLAN ROOF AREA G/H

S-0150 FRAMING PLAN ROOF PLATFORM OVERALL

S-0153 FRAMING PLAN ROOF PLATFORM AREA C/D

S-0155 FRAMING PLAN ROOF PLATFORM AREA E

S-0156 FRAMING PLAN ROOF PLATFORM AREA F

S-0157 FRAMING PLAN ROOF PLATFORM AREA G/H

S-0301 FOUNDATION & FRAMING SECTIONS 1 OF 3

S-0302 FOUNDATION & FRAMING SECTIONS 2 OF 3

S-0303 FOUNDATION & FRAMING SECTIONS 3 OF 3

S-0501 FRAMING SECTIONS & DETAILS 1 OF 2

S-0502 FRAMING SECTIONS & DETAILS 2 OF 2

ELECTRICAL SHEET INDEX

SHEET NUMBER SHEET TITLE

E-0001 ELECTRICAL LEGEND

E-0100 ELECTRICAL DEMOLITION BASEMENT PHASING PLAN

E-0101 ELECTRICAL BASEMENT NEW WORK PHASING PLAN

E-0110 ELECTRICAL DEMOLITION OPERATING FLOOR PHASING PLAN

E-0111 ELECTRICAL OPERATING FLOOR NEW WORK PHASING PLAN

E-0120 ELECTRICAL DEMOLITION MEZZANINE PHASING PLAN

E-0121 ELECTRICAL MEZZANINE NEW WORK PHASING PLAN

E-0140 ELECTRICAL DEMOLITION ROOF PHASING PLAN

E-0141 ELECTRICAL ROOF NEW WORK PHASING PLAN

ED0001 ELECTRICAL DEMOLITION NOTES

ED0100 ELECTRICAL DEMO PLAN - BASEMENT AREA B

ED0103 ELECTRICAL DEMO PLAN - BASEMENT AREA C&D

ED0105 ELECTRICAL DEMO PLAN - BASEMENT AREA E&F

ED0107 ELECTRICAL DEMO PLAN - BASEMENT AREA G&H

ED0110 ELECTRICAL DEMO PLAN - OPERATING FLOOR AREA A&B

ED0113 ELECTRICAL DEMO PLAN - OPERATING FLOOR AREA C&D

ED0115 ELECTRICAL DEMO PLAN - OPERATING FLOOR AREA E&F

ED0117 ELECTRICAL DEMO PLAN - OPERATING FLOOR AREA G&H

ED0118 ELECTRICAL LIGHTING DEMO PLAN - WAX AREA

ED0119 ELECTRICAL POWER DEMO PLAN - WAX AREA

ED0120 ELECTRICAL DEMO PLAN - MEZZANINE AREA A&B

ED0123 ELECTRICAL DEMO PLAN - MEZZANINE AREA C&D

ED0125 ELECTRICAL DEMO PLAN - MEZZANINE AREA E&F

ED0127 ELECTRICAL DEMO PLAN - MEZZANINE AREA G&H

ED0140 ELECTRICAL DEMO PLAN - ROOF AREA A&B

ED0143 ELECTRICAL DEMO PLAN - ROOF AREA C&D

ED0145 ELECTRICAL DEMO PLAN - ROOF AREA E&F

ED0147 ELECTRICAL DEMO PLAN - ROOF AREA G&H

ED0400 ENLARGED ELECTRICAL DEMO PLANS

ED0600 DEMOLITION POWER ONE-LINE DIAGRAM 480Y/277V

ED0601 DEMOLITION POWER ONE-LINE DIAGRAM - 208Y/120V (1 OF 2)

ED0602 DEMOLITION POWER ONE-LINE DIAGRAM - 208Y/120V (2 OF 2)

ED0603 DEMOLITION POWER ONE-LINE DIAGRAM MOTOR CONTROL PANELS

EP0100 ELECTRICAL POWER PLAN - OVERALL BASEMENT

EP0110 ELECTRICAL POWER PLAN - OVERALL OPERATING FLOOR

EP0111 ELECTRICAL POWER PLAN - OVERALL OPERATING FLOOR DC

CONNECTIONS

EP0112 ELECTRICAL POWER PLAN - OVERALL WAX AREA

EP0113 ELECTRICAL POWER PLAN - OVERALL PREP AREA

EP0120 ELECTRICAL POWER PLAN - OVERALL MEZZANINE

EP0121 ELECTRICAL POWER PLAN - OVERALL BUSWAY

EP0140 ELECTRICAL POWER PLAN - OVERALL ROOF

EP0500 CONTROL SCHEMATICS

EP0501 TYPICAL BACK OF TANK POWER & CONTROL CONNECTIONS

EP0503 FRONT OF TANK AC POWER & CONTROL DETAILS

EP0504 FRONT OF TANK AC POWER & CONTROL DETAILS

EP0505 FRONT OF TANK AC POWER & CONTROL DETAILS

EP0506 FRONT OF TANK AC POWER & CONTROL DETAILS

EP0507 FRONT OF TANK AC POWER & CONTROL DETAILS

EP0510 BUSBAR DETAILS

EP0511 BUSBAR DETAILS

EP0512 RECTIFIER CABINET DETAILS

EP0513 TANK DC CONNECTION DETAILS

EP0514 DC CONNECTION DIAGRAMS

EP0515 DC CONNECTION DIAGRAMS

EP0530 EQUIPMENT MOUNTING DETAILS

EP0531 EQUIPMENT MOUNTING DETAILS

EP0540 SECTIONS

EP0600 208Y/120V PANELBOARD SCHEDULES

EP0601 208Y/120V PANELBOARD SCHEDULES

EP0602 208Y/120V PANELBOARD SCHEDULES

EP0603 480Y/277V PANELBOARD SCHEDULES

EP0604 480Y/277V PANELBOARD SCHEDULES

EP0605 480Y/277V PANELBOARD SCHEDULES

EP0606 480Y/277V EMERGENCY PANEL SCHEDULES

EP0607 208Y/120V EMERGENCY PANEL SCHEDULES

EP0608 208Y/120V EMERGENCY PANEL SCHEDULES

EP0609 BUSWAY SCHEDULES

EP0610 BUSWAY SCHEDULES

EP0611 MOTOR CONTROL PANEL SCHEDULES

EP0612 RECTIFIER SCHEDULE

EP0613 MECHANICAL EQUIPMENT SCHEDULE

EP0614 TANK CONTROL SCHEDULE

EP0700 POWER DIAGRAM - BUSWAYS

EP0701 POWER DIAGRAM - EMERGENCY & 208Y/120V SYSTEMS

EI0100 ELECTRICAL INSTRUMENTATION PLAN - OVERALL BASEMENT

EI0110 ELECTRICAL INSTRUMENTATION PLAN - OVERALL OPERATING FLOOR

EI0111 ELECTRICAL INSTRUMENTATION PLAN - OVERALL WAX AREA

EI0113 ELECTRICAL INSTRUMENTATION PLAN - OVERALL PREP AREA

EI0120 ELECTRICAL INSTRUMENTATION PLAN - OVERALL MEZZANINE

EI0140 ELECTRICAL INSTRUMENTATION PLAN - OVERALL ROOF

EI0500 ELECTRICAL INSTRUMENTATION DETAILS

EI0501 ELECTRICAL INSTRUMENTATION DETAILS

EI0502 ELECTRICAL INSTRUMENTATION DETAILS

EI0503 ELECTRICAL INSTRUMENTATION DETAILS

EI0504 ELECTRICAL INSTRUMENTATION DETAILS

EI0505 MAU CONTROL

EI0600 I/O POINTS SCHEDULES

EI0601 I/O POINTS SCHEDULES

EI0602 I/O POINTS SCHEDULES

EI0603 I/O POINTS SCHEDULES

EI0604 I/O POINTS SCHEDULES

EI0605 I/O POINTS SCHEDULES

EI0610 INSTRUMENT SCHEDULE

EI0611 INSTRUMENT SCHEDULE II

EI0700 OVERALL INSTRUMENTATION DIAGRAM

EL0100 ELECTRICAL LIGHTING PLAN - OVERALL BASEMENT

EL0110 ELECTRICAL LIGHTING PLAN - OVERALL OPERATING FLOOR

EL0112 ELECTRICAL LIGHTING PLAN - OVERALL WAX AREA

EL0120 ELECTRICAL LIGHTING PLAN - OVERALL MEZZANINE

EL0500 ELECTRICAL LIGHTING DETAILS

EL0600 LIGHT FIXTURE AND CONTROLS SCHEDULES

FIRE PROTECTION SHEET INDEX

SHEET NUMBER SHEET TITLE

FX0001 FIRE PROTECTION LEGEND AND ABBREVIATIONS

FX0100 FIRE PROTECTION PLAN BASEMENT

FX0110 FIRE PROTECTION PLAN OPERATING FLOOR

FX0120 FIRE PROTECTION PLAN MEZZANINE

FA0001 FIRE ALARM AND MASS NOTIFICATION LEGEND

FA0100 FIRE ALARM AND MASS NOTIFICATION PLAN BASEMENT

FA0110 FIRE ALARM AND MASS NOTIFICATION PLAN OPERATING FLOOR

FA0140 FIRE ALARM AND MASS NOTIFICATION PLAN ROOF

FA0601 FIRE ALARM RISER

FA0602 FIRE ALARM MATRIX

SET 1 OF 8

5 4 3 2 1

12345

D

C

B

A ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

A

B

C

D

US Army Corps of Engineers

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

SYMBOL REVISIONS DATE APPROVED

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

42x30

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

C O P Y R I G H T

W912BV-15-R0093

ELECTRICAL GENERAL NOTES

PHASE 1:

1. INSTALL NEW PROCESS CONTROLS SYSTEM IN THE NEW

CONTROL ROOM. INSTALL PLC'S, SERVERS, SWITCHES, PATCH

PANELS, CENTRAL WORKSTATION, CONNECTIONS TO PMXG

OFFICE COMPUTERS, CONNECTION TO FISHER SCIENTIFIC LIMS

SERVER AND ALL ASSOCIATED CABLING AND RACEWAYS.

PREPARE THE PROCESS CONTROL SYSTEM FOR PHASE 2

AREAS.

2. PROVIDE POWER TO CHROME SCRUBBER WATER

RECIRCULATION PUMP P582B IN TEMPORARY LOCATION (SEE

SHEET ED0400).

3. REMOVE POWER, LIGHTING AND CONTROLS IN PHASE 1 DEMO

AREAS AS INDICATED ON ELECTRICAL DEMOLITION DRAWINGS.

PHASE 2:

1. PROVIDE POWER TO RO WATER SYSTEM AS INDICATED ON

ELECTRICAL DRAWINGS. PROVIDE POWER TO RO WATER

SYSTEM DISTRIBUTION PUMPS P-101 AND P-102 IN

TEMPORARY LOCATION OUTSIDE WEST OF AREA A (SEE

SHEET ED0400).

2. REMOVE POWER, LIGHTING AND CONTROLS IN PHASE 2 DEMO

AREAS AS INDICATED ON ELECTRICAL DEMOLITION

DRAWINGS.

3. PROVIDE NEW POWER, LIGHTING AND CONTROLS IN PHASE 2

NEW WORK AREAS AS INDICATED ON ELECTRICAL DRAWINGS.

PROVIDE POWER TO RO WATER SYSTEM DISTRIBUTION

PUMPS P-101 AND P-102 IN FINAL LOCATION. REMOVE PUMP

FEEDERS IN TEMPORARY LOCATION (SEE SHEET ED0400).

PHASE 3:

1. PROVIDE POWER TO MASKING TABLE IN AREA A TEMPORARY

LOCATION (SEE SHEET ED0400).

2. PROVIDE NEW POWER, LIGHTING AND CONTROLS IN PHASE 3

NEW WORK AREAS AS INDICATED ON ELECTRICAL DRAWINGS.

3. REMOVE POWER, LIGHTING AND CONTROLS IN PHASE 3 DEMO

AREAS AS INDICATED ON ELECTRICAL DEMOLITION

DRAWINGS.

PHASE 4:

1. PROVIDE NEW POWER, LIGHTING AND CONTROLS IN PHASE 4

NEW WORK AREAS AS INDICATED ON ELECTRICAL DRAWINGS.

2. REMOVE POWER, LIGHTING AND CONTROLS IN PHASE 4 DEMO

AREAS AS INDICATED ON ELECTRICAL DEMOLITION

DRAWINGS.

PHASE 5:

1. PROVIDE NEW POWER, LIGHTING AND CONTROLS IN PHASE 5

NEW WORK AREAS AS INDICATED ON ELECTRICAL DRAWINGS.

2. REMOVE POWER, LIGHTING AND CONTROLS IN PHASE 5 DEMO

AREAS AS INDICATED ON ELECTRICAL DEMOLITION

DRAWINGS.

3. REMOVE EXHAUST FAN MOTOR CONTROL PANELS ALONG

WALL EAST OF AREA B.

4. REMOVE PROCESS CONTROL CENTRAL ANNUNCIATOR PANEL

ON WALL EAST OF AREA B.

5. REROUTE POWER TO EXISTING OVEN IN TEMPORARY

LOCATION AT EAST END OF AREA B (SEE SHEET ED0400).

REPLACE EXISTING FEEDER.

6. REMOVE POWER FROM CHROME SCRUBBER WATER

RECIRCULATION PUMP P582B IN TEMPORARY LOCATION (SEE

SHEET ED0400). PUMP SHALL BE REMOVED FROM SERVICE.

PHASE 6:

1. PROVIDE NEW POWER, LIGHTING AND CONTROLS IN PHASE 6

NEW WORK AREAS AS INDICATED ON ELECTRICAL DRAWINGS.

2. RELOCATE OVEN TO FINAL AREA B LOCATION AND PROVIDE

NEW FEEDER. REMOVE TEMPORARY FEEDER (SEE SHEET

ED0400).

GENERAL ELECTRICAL NOTES:

GENERAL PHASING ELECTRICAL GUIDELINES

1. WORK IS LIMITED TO PHASE AREAS INDICATED ON GENERAL PHASING

PLANS UON OR WHEN PERFORMING WORK OUTSIDE A PHASE AREA IS

ABSOLUTELY NECESSARY. COORDINATE WORK WITH CONTRACTING

OFFICER TO ENSURE MINIMAL INTERRUPTIONS TO NORMAL SHOP

OPERATIONS IN AREAS OUTSIDE THE CURRENT CONSTRUCTION

PHASE.

2. WORK MAY BE PERFORMED IN THE MAIN NORTH/SOUTH AISLES OF

THE SHOP OPERATING FLOOR (WEST AND EAST SIDES) DURING ANY

PHASE AS LONG AS INTERRUPTIONS TO NORMAL SHOP OPERATIONS

ARE MINIMIZED AND COORDINATED WITH THE CONTRACTING OFFICER

BEFORE STARTING WORK.

3. COORDINATE WITH REPLACEMENT OF OPERATING FLOORS FOR

ACCESS TO EXISTING EQUIPMENT UNDER MEZZANINES.

4. PANELBOARD AND BUSWAY SCHEDULES ON EP0600 SERIES SHEETS

REPRESENT FINAL STATE OF PANELBOARDS AND BUSWAYS AFTER

ALL PHASES ARE COMPLETE. MAINTAIN POWER TO EXISTING LOADS

UNTIL THE PHASE IN WHICH THEY ARE REMOVED.

5. ELECTRICAL WORK MAY BE PERFORMED ON MEZZANINES ADJACENT

TO PHASE AREAS DURING THE SAME PHASE (EVEN IF MEZZANINE IS

NOT SHOWN WITHIN THE PHASE BOUNDARY ON THE PHASING PLAN).

CARE SHALL BE TAKEN TO ENSURE NO MATERIALS, TOOLS, ETC. ARE

DROPPED INTO ACTIVE TANK AREAS. DUST CURTAINS SHALL BE

INSTALLED BETWEEN ACTIVE AREAS AND CURRENT PHASE WORK

AREAS TO PREVENT CONTAMINATION OF ACTIVE TANK AREAS.

ACTIVE TANKS SHALL BE COVERED WITH PLYWOOD AND VISQUEEN

WHEN WORKING IN THE SAME VICINITY.

6. ALL CONDUITS SHALL BE REMOVED BACK TO THE SOURCE OR

CURRENT PHASE BOUNDARY AND FURTHER REMOVED IN

SUBSEQUENT PHASES UNTIL COMPLETELY REMOVED BACK TO THE

SOURCE.

7. EXISTING PROCESS CONTROL SYSTEM COMPONENTS WHICH ARE

CURRENTLY ACTIVE SHALL REMAIN UNTIL NO LONGER REQUIRED TO

SUPPORT EXISTING PROCESSES. CONTROLS SHALL NOT BE

REMOVED UNTIL THE ASSOCIATED PROCESS EQUIPMENT IS

REMOVED.

8. THE EMERGENCY STANDBY GENERATOR SHALL BE TESTED AND

COMMISSIONED AT THE COMPLETION OF EACH PHASE.

9. TESTING AND TRAINING ON POWER, LIGHTING AND CONTROLS

SYSTEMS SHALL OCCUR AFTER EACH PHASE OF WORK. ONLY AFTER

ALL PHASES ARE COMPLETE WILL FINAL TESTING AND ACCEPTANCE

FOR EACH SYSTEM OCCUR.

PHASING NEW WORK KEY PLAN:PHASING DEMOLITION KEY PLAN:

AREA

A

AREA

B

AREA

C

AREA

D

AREA

E

AREA

F

AREA

G

AREA

H

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PHASE 1

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PH

A

SE

PHASE 2

FIRE PROTECTION GENERAL NOTES

FIRE SPRINKLER:

1. DEMOLITION ACTIVITIES SHALL FOLLOW THE GENERAL

PHASING PLAN.

2. DEMOLITION IN EACH PHASE SHALL BE PLANNED AND

COORDINATED TO MINIMIZE THE IMPAIRMENT TIME TO THE

SYSTEM.

3. ONLY THE BRANCH LINES ARE TO BE REMOVED ON THE

SPRINKLER SYSTEM IN THE BASEMENT. CROSS AND FEED

MAINS ARE TO REMAIN.

4. PIPING THAT REMAINS IN SERVICE AFTER A DEMOLITION PHASE

SHALL BE PROPERLY SUPPORTED AND PROTECTED TO

PREVENT DAMAGE.

5. PRESSURE TEST EACH NEW BRANCH LINE PRIOR TO IMPAIRING

THE SYSTEM TO MAKE THE FINAL CONNECTION.

FIRE ALARM:

1. THE EXISTING FIRE ALARM \ MASS NOTIFICATION SYSTEM

SHALL BE MODIFIED ACCORDING TO THE GENERAL PHASING

PLAN.

2. DEMOLITION IN EACH PHASE SHALL BE PLANNED AND

COORDINATED TO MINIMIZE THE IMPAIRMENT TIME TO THE

SYSTEM.

3. IF WIRING FOR A PHASE IN DEMOLITION REQUIRES REMOVING

CONDUIT AND WIRE FEEDING DEVICES IN OTHER PHASES THAT

MUST REMAIN OPERATIONAL, TEMPORARY WIRING SHALL BE

INSTALLED TO MAINTAIN THOSE DEVICES IN SERVICE.

4. FIRE ALARM/MASS NOTIFICATION SYSTEM MODIFICATIONS

SHALL BE TESTED IN EACH PHASE.

AREA

A

AREA

B

AREA

C

AREA

D

AREA

E

AREA

F

AREA

G

AREA

H

MECHANICAL GENERAL NOTES

PHASE 1:

1. REFER TO SHEET G-0006 FOR LEGEND AND ABBREVIATIONS.

2. "RENOVATE" INCLUDES, AS APPLICABLE, REMOVAL OF EXISTING

TANKS, PUMPS, PIPING, SCRUBBERS, FANS, CONDENSING UNITS, AND

EQUIPMENT WITH LINES AS INDICATED ON GENERAL PHASING

SHEETS. SEE STRUCTURAL, ELECTRICAL AND ARCHITECTURAL

DRAWINGS FOR SCOPE OF RENOVATION FOR THOSE DISCIPLINES IN

THIS PHASE. SEE GENERAL PHASING SHEETS G-1100, G-1110, G-1140

FOR MECHANICAL WORK TO BE PERFORMED DURING PHASE 1

RENOVATION.

3. "DEMOLISH" INCLUDES, AS APPLICABLE, REMOVAL OF TANKS, PUMPS,

PIPING, EQUIPMENT, EQUIPMENT PADS, SUPPORTS, HANGERS,

VALVES, FITTINGS, DUCTWORK, SCRUBBERS, AND FANS FROM THE

SITE AND DISPOSAL AS DIRECTED BY THE CLIENT.

4. "INSTALL" INCLUDES, AS APPLICABLE, NEW TANKS, PIPING,

EQUIPMENT, EQUIPMENT PADS, OPERATING FLOOR, SCRUBBERS,

FANS, AND SUPPORT STEEL AS REQUIRED. SEE GENERAL PHASING

SHEETS G-1100, G-1110, G-1140 FOR WORK TO BE PERFORMED

DURING PHASE 1 RENOVATION.

5. SEE KEYED NOTE 1 ON SHEET G-1100 AND SHEET G-1110 FOR PHASE 1

WORK TO OCCUR BEFORE RENOVATION OF AREA F.

6. SEE PHASE 1 DEMOLITION DRAWINGS FOR DEMOLITION MECHANICAL

WORK TO BE PERFORMED DURING PHASE 1.

7. SEE PHASE 1 NEW WORK DRAWINGS FOR NEW MECHANICAL WORK

TO BE PERFORMED DURING PHASE 1.

8. SEE DRAWINGS G-1100 FOR PHASE 1 MECH PHASING PLAN

BASEMENT, G-1110 FOR PHASE 1 MECH PHASING PLAN OPERATING

FLOOR AND G-1140 FOR PHASE 1 MECH PHASING PLAN ROOF.

9. CONTRACTOR SHALL BE KNOWLEDGEABLE OF ALL PHASES AND

SHALL NAVIGATE BETWEEN PHASES TO REFERENCE AREAS NOT

AFFECTED BY WORK IN THIS PHASE.

10. REFER TO STRUCTURAL , ELECTRICAL, AND ARCHITECTURAL

DRAWINGS FOR SPECIFIC DISCIPLINE PHASING INFORMATION.

11. ALL DETAILS, SECTIONS, SCHEDULES, P&IDS, FLOW DIAGRAMS,

ISOMETRICS COMMON TO MULTIPLE PHASES SHALL BE LOCATION IN

PHASE 0.

12. ALL PIPING ELEVATIONS LISTED ON ALL BASEMENT MP SHEETS ARE

TAKEN IN REFERENCE TO THE OPERATING FLOOR.

13. FOR ALL ROOF PENETRATIONS NOT BEING RE-USED/BEING PATCHED,

REFER TO ARCHITECTURAL DETAILS ON SHEET A-0500 FOR

ADDITIONAL INFORMATION.

PHASE 2:

1. REFER TO SHEET G-0006 FOR LEGEND AND ABBREVIATIONS.

2. "RENOVATE" INCLUDES, AS APPLICABLE, REMOVAL OF EXISTING TANKS,

PUMPS, PIPING, SCRUBBERS, FANS, CONDENSING UNITS, AND

EQUIPMENT WITH LINES AS INDICATED ON GENERAL PHASING SHEETS.

SEE STRUCTURAL, ELECTRICAL AND ARCHITECTURAL DRAWINGS FOR

SCOPE OF RENOVATION FOR THOSE DISCIPLINES IN THIS PHASE. SEE

GENERAL PHASING SHEETS G-2100, G-2110, G-2120, G-2140 FOR

MECHANICAL WORK TO BE PERFORMED DURING PHASE 2 RENOVATION.

3. "DEMOLISH" INCLUDES, AS APPLICABLE, REMOVAL OF TANKS, PUMPS,

PIPING, EQUIPMENT, EQUIPMENT PADS, SUPPORTS, HANGERS, VALVES,

FITTINGS, DUCTWORK, SCRUBBERS, AND FANS FROM THE SITE AND

DISPOSAL AS DIRECTED BY THE CLIENT.

4. "INSTALL" INCLUDES, AS APPLICABLE, NEW TANKS, PIPING, EQUIPMENT,

EQUIPMENT PADS, OPERATING FLOOR, SCRUBBERS, FANS, AND

SUPPORT STEEL AS REQUIRED. SEE GENERAL PHASING SHEETS G-2100,

G-2110, G-2140 FOR WORK TO BE PERFORMED DURING PHASE 2

RENOVATION.

5. SEE KEYED NOTE 1 AND 2 ON SHEET G-1100 AND KEYED NOTE 1 ON

SHEET G-1110 FOR PHASE 2 NEW WORK TO OCCUR BEFORE

RENOVATION OF AREA C AND D.

6. SEE PHASE 2 DEMOLITION DRAWINGS FOR DEMOLITION MECHANICAL

WORK TO BE PERFORMED DURING PHASE 2.

7. SEE PHASE 2 NEW WORK DRAWINGS FOR NEW MECHANICAL WORK TO

BE PERFORMED DURING PHASE 2.

8. SEE DRAWINGS G-2100 FOR PHASE 2 MECH PHASING PLAN BASEMENT,

G-2110 FOR PHASE 2 MECH PHASING PLAN OPERATING FLOOR AND

G-2140 FOR PHASE 2 MECH PHASING PLAN ROOF.

9. CONTRACTOR SHALL BE KNOWLEDGEABLE OF ALL PHASES AND SHALL

NAVIGATE BETWEEN PHASES TO REFERENCE AREAS NOT AFFECTED BY

WORK IN THIS PHASE.

10. REFER TO STRUCTURAL , ELECTRICAL, AND ARCHITECTURAL DRAWINGS

FOR SPECIFIC DISCIPLINE PHASING INFORMATION.

11. ALL DETAILS, SECTIONS, SCHEDULES, P&IDS, FLOW DIAGRAMS,

ISOMETRICS COMMON TO MULTIPLE PHASES SHALL BE LOCATION IN

PHASE 0.

12. ALL PIPING ELEVATIONS LISTED ON ALL BASEMENT MP SHEETS ARE

TAKEN IN REFERENCE TO THE OPERATING FLOOR.

13. FOR ALL ROOF PENETRATIONS NOT BEING RE-USED/BEING PATCHED,

REFER TO ARCHITECTURAL DETAILS ON SHEET A-0500 FOR ADDITIONAL

INFORMATION.

PHASE 3:

1. REFER TO SHEET G-0006 FOR LEGEND AND ABBREVIATIONS.

2. "RENOVATE" INCLUDES, AS APPLICABLE, REMOVAL OF

EXISTING TANKS, PUMPS, PIPING, SCRUBBERS, FANS,

CONDENSING UNITS, AND EQUIPMENT WITH LINES AS

INDICATED ON GENERAL PHASING SHEETS. SEE STRUCTURAL,

ELECTRICAL AND ARCHITECTURAL DRAWINGS FOR SCOPE OF

RENOVATION FOR THOSE DISCIPLINES IN THIS PHASE. SEE

GENERAL PHASING SHEETS G-3100, G-3110, G-3120, G-3140

FOR MECHANICAL WORK TO BE PERFORMED DURING PHASE 3

RENOVATION.

3. "DEMOLISH" INCLUDES, AS APPLICABLE, REMOVAL OF TANKS,

PUMPS, PIPING, EQUIPMENT, EQUIPMENT PADS, SUPPORTS,

HANGERS, VALVES, FITTINGS, DUCTWORK, SCRUBBERS, AND

FANS FROM THE SITE AND DISPOSAL AS DIRECTED BY THE

CLIENT.

4. "INSTALL" INCLUDES, AS APPLICABLE, NEW TANKS, PIPING,

EQUIPMENT, EQUIPMENT PADS, OPERATING FLOOR,

SCRUBBERS, FANS, AND SUPPORT STEEL AS REQUIRED. SEE

GENERAL PHASING SHEETS G-3100, G-3110, G-3140 FOR WORK

TO BE PERFORMED DURING PHASE 3 RENOVATION.

5. SEE PHASE 3 DEMOLITION DRAWINGS FOR DEMOLITION

MECHANICAL WORK TO BE PERFORMED DURING PHASE 3.

6. SEE PHASE 3 NEW WORK DRAWINGS FOR NEW MECHANICAL

WORK TO BE PERFORMED DURING PHASE 3.

7. SEE DRAWINGS G-3100 FOR PHASE 3 MECH PHASING PLAN

BASEMENT, G-3110 FOR PHASE 3 MECH PHASING PLAN

OPERATING FLOOR AND G-3140 FOR PHASE 3 MECH PHASING

PLAN ROOF.

8. CONTRACTOR SHALL BE KNOWLEDGEABLE OF ALL PHASES

AND SHALL NAVIGATE BETWEEN PHASES TO REFERENCE

AREAS NOT AFFECTED BY WORK IN THIS PHASE.

9. REFER TO STRUCTURAL , ELECTRICAL, AND ARCHITECTURAL

DRAWINGS FOR SPECIFIC DISCIPLINE PHASING INFORMATION.

10. ALL DETAILS, SECTIONS, SCHEDULES, P&IDS, FLOW

DIAGRAMS, ISOMETRICS COMMON TO MULTIPLE PHASES

SHALL BE LOCATION IN PHASE 0.

11. ALL PIPING ELEVATIONS LISTED ON ALL BASEMENT MP

SHEETS ARE TAKEN IN REFERENCE TO THE OPERATING

FLOOR.

12. FOR ALL ROOF PENETRATIONS NOT BEING RE-USED/BEING

PATCHED, REFER TO ARCHITECTURAL DETAILS ON SHEET

A-0500 FOR ADDITIONAL INFORMATION.

PHASE 4:

1. REFER TO SHEET G-0006 FOR LEGEND AND ABBREVIATIONS.

2. "RENOVATE" INCLUDES, AS APPLICABLE, REMOVAL OF

EXISTING TANKS, PUMPS, PIPING, SCRUBBERS, FANS,

CONDENSING UNITS, AND EQUIPMENT WITH LINES AS

INDICATED ON GENERAL PHASING SHEETS. SEE STRUCTURAL,

ELECTRICAL AND ARCHITECTURAL DRAWINGS FOR SCOPE OF

RENOVATION FOR THOSE DISCIPLINES IN THIS PHASE. SEE

GENERAL PHASING SHEETS G-4100, G-4110, G-4120, G-4140

FOR MECHANICAL WORK TO BE PERFORMED DURING PHASE 4

RENOVATION.

3. "DEMOLISH" INCLUDES, AS APPLICABLE, REMOVAL OF TANKS,

PUMPS, PIPING, EQUIPMENT, EQUIPMENT PADS, SUPPORTS,

HANGERS, VALVES, FITTINGS, DUCTWORK, SCRUBBERS, AND

FANS FROM THE SITE AND DISPOSAL AS DIRECTED BY THE

CLIENT.

4. "INSTALL" INCLUDES, AS APPLICABLE, NEW TANKS, PIPING,

EQUIPMENT, EQUIPMENT PADS, OPERATING FLOOR,

SCRUBBERS, FANS, AND SUPPORT STEEL AS REQUIRED. SEE

GENERAL PHASING SHEETS G-4100, G-4110, G-4140 FOR WORK

TO BE PERFORMED DURING PHASE 4 RENOVATION.

5. SEE PHASE 4 DEMOLITION DRAWINGS FOR DEMOLITION

MECHANICAL WORK TO BE PERFORMED DURING PHASE 4.

6. SEE PHASE 4 NEW WORK DRAWINGS FOR NEW MECHANICAL

WORK TO BE PERFORMED DURING PHASE 4.

7. SEE DRAWINGS G-4100 FOR PHASE 4 MECH PHASING PLAN

BASEMENT, G-4110 FOR PHASE 4 MECH PHASING PLAN

OPERATING FLOOR AND G-4140 FOR PHASE 4 MECH PHASING

PLAN ROOF.

8. CONTRACTOR SHALL BE KNOWLEDGEABLE OF ALL PHASES

AND SHALL NAVIGATE BETWEEN PHASES TO REFERENCE

AREAS NOT AFFECTED BY WORK IN THIS PHASE.

9. REFER TO STRUCTURAL , ELECTRICAL, AND ARCHITECTURAL

DRAWINGS FOR SPECIFIC DISCIPLINE PHASING INFORMATION.

10. ALL DETAILS, SECTIONS, SCHEDULES, P&IDS, FLOW

DIAGRAMS, ISOMETRICS COMMON TO MULTIPLE PHASES

SHALL BE LOCATION IN PHASE 0.

11. ALL PIPING ELEVATIONS LISTED ON ALL BASEMENT MP

SHEETS ARE TAKEN IN REFERENCE TO THE OPERATING

FLOOR.

12. FOR ALL ROOF PENETRATIONS NOT BEING RE-USED/BEING

PATCHED, REFER TO ARCHITECTURAL DETAILS ON SHEET

A-0500 FOR ADDITIONAL INFORMATION.

PHASE 5:

1. REFER TO SHEET G-0006 FOR LEGEND AND ABBREVIATIONS.

2. "RENOVATE" INCLUDES, AS APPLICABLE, REMOVAL OF

EXISTING TANKS, PUMPS, PIPING, SCRUBBERS, FANS,

CONDENSING UNITS, AND EQUIPMENT WITH LINES AS

INDICATED ON GENERAL PHASING SHEETS. SEE STRUCTURAL,

ELECTRICAL AND ARCHITECTURAL DRAWINGS FOR SCOPE OF

RENOVATION FOR THOSE DISCIPLINES IN THIS PHASE. SEE

GENERAL PHASING SHEETS G-5100, G-5110, G-5120, G-5140

FOR MECHANICAL WORK TO BE PERFORMED DURING PHASE 5

RENOVATION.

3. "DEMOLISH" INCLUDES, AS APPLICABLE, REMOVAL OF TANKS,

PUMPS, PIPING, EQUIPMENT, EQUIPMENT PADS, SUPPORTS,

HANGERS, VALVES, FITTINGS, DUCTWORK, SCRUBBERS, AND

FANS FROM THE SITE AND DISPOSAL AS DIRECTED BY THE

CLIENT.

4. "INSTALL" INCLUDES, AS APPLICABLE, NEW TANKS, PIPING,

EQUIPMENT, EQUIPMENT PADS, OPERATING FLOOR,

SCRUBBERS, FANS, AND SUPPORT STEEL AS REQUIRED. SEE

GENERAL PHASING SHEETS G-5100, G-5110, G-5140 FOR WORK

TO BE PERFORMED DURING PHASE 5 RENOVATION.

5. SEE PHASE 5 DEMOLITION DRAWINGS FOR DEMOLITION

MECHANICAL WORK TO BE PERFORMED DURING PHASE 5.

6. SEE PHASE 5 NEW WORK DRAWINGS FOR NEW MECHANICAL

WORK TO BE PERFORMED DURING PHASE 5.

7. SEE DRAWINGS G-5100 FOR PHASE 5 MECH PHASING PLAN

BASEMENT, G-5110 FOR PHASE 5 MECH PHASING PLAN

OPERATING FLOOR AND G-5140 FOR PHASE 5 MECH PHASING

PLAN ROOF.

8. CONTRACTOR SHALL BE KNOWLEDGEABLE OF ALL PHASES

AND SHALL NAVIGATE BETWEEN PHASES TO REFERENCE

AREAS NOT AFFECTED BY WORK IN THIS PHASE.

9. REFER TO STRUCTURAL , ELECTRICAL, AND ARCHITECTURAL

DRAWINGS FOR SPECIFIC DISCIPLINE PHASING INFORMATION.

10. ALL DETAILS, SECTIONS, SCHEDULES, P&IDS, FLOW

DIAGRAMS, ISOMETRICS COMMON TO MULTIPLE PHASES

SHALL BE LOCATION IN PHASE 0.

11. ALL PIPING ELEVATIONS LISTED ON ALL BASEMENT MP

SHEETS ARE TAKEN IN REFERENCE TO THE OPERATING

FLOOR.

12. FOR ALL ROOF PENETRATIONS NOT BEING RE-USED/BEING

PATCHED, REFER TO ARCHITECTURAL DETAILS ON SHEET

A-0500 FOR ADDITIONAL INFORMATION.

PHASE 6:

1. REFER TO SHEET G-0006 FOR LEGEND AND ABBREVIATIONS.

2. "RENOVATE" INCLUDES, AS APPLICABLE, REMOVAL OF

EXISTING TANKS, PUMPS, PIPING, SCRUBBERS, FANS,

CONDENSING UNITS, AND EQUIPMENT WITH LINES AS

INDICATED ON GENERAL PHASING SHEETS. SEE STRUCTURAL,

ELECTRICAL AND ARCHITECTURAL DRAWINGS FOR SCOPE OF

RENOVATION FOR THOSE DISCIPLINES IN THIS PHASE. SEE

GENERAL PHASING SHEETS G-6100, G-6110, G-6140 FOR

MECHANICAL WORK TO BE PERFORMED DURING PHASE 6

RENOVATION.

3. "DEMOLISH" INCLUDES, AS APPLICABLE, REMOVAL OF TANKS,

PUMPS, PIPING, EQUIPMENT, EQUIPMENT PADS, SUPPORTS,

HANGERS, VALVES, FITTINGS, DUCTWORK, SCRUBBERS, AND

FANS FROM THE SITE AND DISPOSAL AS DIRECTED BY THE

CLIENT.

4. "INSTALL" INCLUDES, AS APPLICABLE, NEW TANKS, PIPING,

EQUIPMENT, EQUIPMENT PADS, OPERATING FLOOR,

SCRUBBERS, FANS, AND SUPPORT STEEL AS REQUIRED. SEE

GENERAL PHASING SHEETS G-6100, G-6110, G-6140 FOR WORK

TO BE PERFORMED DURING PHASE 6.

5. SEE PHASE 6 NEW WORK DRAWINGS FOR NEW MECHANICAL

WORK TO BE PERFORMED DURING PHASE 6.

6. SEE DRAWINGS G-6100 FOR PHASE 6 MECH PHASING PLAN

BASEMENT, G-6110 FOR PHASE 6 MECH PHASING PLAN

OPERATING FLOOR AND G-6140 FOR PHASE 6 MECH PHASING

PLAN ROOF.

7. CONTRACTOR SHALL BE KNOWLEDGEABLE OF ALL PHASES

AND SHALL NAVIGATE BETWEEN PHASES TO REFERENCE

AREAS NOT AFFECTED BY WORK IN THIS PHASE.

8. REFER TO STRUCTURAL , ELECTRICAL, AND ARCHITECTURAL

DRAWINGS FOR SPECIFIC DISCIPLINE PHASING INFORMATION.

9. ALL DETAILS, SECTIONS, SCHEDULES, P&IDS, FLOW

DIAGRAMS, ISOMETRICS COMMON TO MULTIPLE PHASES

SHALL BE LOCATION IN PHASE 0.

10. ALL PIPING ELEVATIONS LISTED ON ALL BASEMENT MP

SHEETS ARE TAKEN IN REFERENCE TO THE OPERATING

FLOOR.

11. FOR ALL ROOF PENETRATIONS NOT BEING RE-USED/BEING

PATCHED, REFER TO ARCHITECTURAL DETAILS ON SHEET

A-0500 FOR ADDITIONAL INFORMATION.

M. SCHLUENDER

C. MCAFEE

M. SCHLUENDER

G. REWALD

J. KLING

1:1

NOTES

GENERAL PHASING

G-0005

SET 1-MG0005.DWG

8/26/14

UP

UP UP UP UP

UP

61.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

59.959.358.758.157.556.956.355.755.154.553.953.4 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

BASEMENT

1 1

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 AD0100

OVERALL DEMOLITION PLAN -

BASEMENT

A. WHITENER

D. SCOTT

A. WHITENER

78794AD0100.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 OVERALL DEMOLITION PLAN - BASEMENT

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO EACH

PHASE OF CONSTRUCTION.

2. IF SAND BLASTING IS REQUIRED TO REMOVE EXISTING COATINGS - PROVIDE

FIRE TREATED PLYWOOD + ANTI STATIC, FIRE RETARDANT FABRIC WALL TO

PROTECT ADJACENT AREAS FROM DUST.

DEMO KEYNOTE LEGEND

1 REMOVE EXISTING METAL STAIR , STRINGERS & HANDRAIL . PATCH HOLE

WHERE ANCHOR BOLTS WERE REMOVED WITH HIGH STRENGTH

NON-SHRINK GROUT.

2 REMOVE METAL PANEL WALL AS SHOWN. PATCH HOLES IN FLOOR AND

CEILING WHERE ANCHORS WERE REMOVED WITH HIGH STRENGTH,

NON-SHRINK GROUT. SAVE METAL PANELS FOR REUSE.

3 REMOVE EXISTING HOLLOW METAL DOOR(S), FRAME & HARDWARE.

4 REMOVE EXISTING MASONRY & METAL PANEL WALL TO FORM NEW

OPENING.

7 DEMOLISH ROOF AND PREPARE FOR NEW PENETRATION AND CURB.

COORDINATE WITH STRUCTURAL AND MECHANICAL.

N

0 4' 8' 16'

UP UP

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.452.9 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

ELECTROLESS

NICKEL PLATING

NICKEL PLATING

PLC/FIRE

WATER TREATMENT

31' - 3 1/2"

CORRIDOR

6'

- 4

" W m in x 7

4"

H

2'

- 2

3/ 4"

1 1

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 AD0110

OVERALL DEMOLITION PLAN -

OPERATING FLOOR

A. WHITENER

D. SCOTT

A. WHITENER

78794AD0110.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 DEMO PLAN - OPERATING FLOOR

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO

EACH PHASE OF CONSTRUCTION.

2. IF SAND BLASTING IS REQUIRED TO REMOVE EXISTING COATINGS - PROVIDE

FIRE TREATED PLYWOOD + ANTI STATIC, FIRE RETARDANT FABRIC WALL TO

PROTECT ADJACENT AREAS FROM DUST.

DEMO KEYNOTE LEGEND

1 REMOVE EXISTING METAL STAIR , STRINGERS & HANDRAIL . PATCH HOLE

WHERE ANCHOR BOLTS WERE REMOVED WITH HIGH STRENGTH

NON-SHRINK GROUT.

2 REMOVE METAL PANEL WALL AS SHOWN. PATCH HOLES IN FLOOR AND

CEILING WHERE ANCHORS WERE REMOVED WITH HIGH STRENGTH,

NON-SHRINK GROUT. SAVE METAL PANELS FOR REUSE.

3 REMOVE EXISTING HOLLOW METAL DOOR(S), FRAME & HARDWARE.

4 REMOVE EXISTING MASONRY & METAL PANEL WALL TO FORM NEW

OPENING.

7 DEMOLISH ROOF AND PREPARE FOR NEW PENETRATION AND CURB.

COORDINATE WITH STRUCTURAL AND MECHANICAL.

N

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.4 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

17' - 4"

NEW FIBERGLASS GRATING

OVER PLATFORM

RE: STRUCTURAL FOR SIZE

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

05/06/15 AD0140

OVERALL DEMOLITION PLAN - ROOF

A. WHITENER

D. SCOTT

A. WHITENER

78794AD0140.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"1 DEMO PLAN - ROOF

N

0 4' 8' 16'

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO

EACH PHASE OF CONSTRUCTION.

2. INFILL ANY UNUSED PENETRATIONS. COORDINATE WITH MECHANICAL.

REFERENCE SHEET A-0500 FOR CORRESPONDING DETAILS.

3. REROOF OF ENTIRE PLATING SHOP AREA AS SHOWN BID OPTION NO. 2.

REFERENCE SHEET A-0500 FOR CORRESPONDING DETAILS.

DEMO KEYNOTE LEGEND

1 REMOVE EXISTING METAL STAIR , STRINGERS & HANDRAIL . PATCH HOLE

WHERE ANCHOR BOLTS WERE REMOVED WITH HIGH STRENGTH

NON-SHRINK GROUT.

2 REMOVE METAL PANEL WALL AS SHOWN. PATCH HOLES IN FLOOR AND

CEILING WHERE ANCHORS WERE REMOVED WITH HIGH STRENGTH,

NON-SHRINK GROUT. SAVE METAL PANELS FOR REUSE.

3 REMOVE EXISTING HOLLOW METAL DOOR(S), FRAME & HARDWARE.

4 REMOVE EXISTING MASONRY & METAL PANEL WALL TO FORM NEW

OPENING.

7 DEMOLISH ROOF AND PREPARE FOR NEW PENETRATION AND CURB.

COORDINATE WITH STRUCTURAL AND MECHANICAL.

CP

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.452.9 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

27903.94 SF

BASEMENT

2'

- 6

1/ 2"

NORMALLY UNOCCUPIED

EQUIPMENT ACCESS

INDUSTRIAL 1 PERSON / 100 SQFT

0 PERSONS

NUMBER OF OCCUPANTS

ROOM NAME

AREA

CLEAR WIDTH

EXIT CAPACITY

OCCUPANTS SERVED

COMMON PATH

OF TRAVEL

TRAVEL

DISTANCE

EGRESS

PATH

COMMON PATH

TERMINATION

POINT

EXIT DOOR

REQUIRED WIDTH

36"

22"

44" 44"

NAME

XX

111SF

GENERAL NOTES

1. REFER TO ARCHITECTURAL LEGEND FOR ADDITIONAL

INFORMATION REGARDING SYMBOLS AND

ABBREVIATIONS.

2. REFER TO AG003 FOR LIFE SAFETY NARRATIVE AND

BUILDING CODE ANALYSIS.

3. REFER TO THE ELECTRICAL LIGHTING PLANS FOR

LOCATION OF EXIT SIGNS AND EMERGENCY

LIGHTING.

4. REFER TO THE FIRE SUPPRESSION AND ALARM PLANS

FOR LOCATION OF FIRE PROTECTION DEVICES.

5. FINAL LOCATIONS OF FIRE EXTINGUISHERS AND

HOSE REELS SHALL BE APPROVED BY THE AHJ PRIOR

TO INSTALLATION.

DOOR EGRESS TAG STAIR EGRESS TAG

ROOM OCCUPANCY TAG

EGRESS PATH

100'CP:666'

A:B:C: TYPE DRY CHEMICAL

4A-20B-C

PORTABLE FIRE EXTINGUISHERS AND HOSE REELS

FE:SR

EXTINGUISHER /HOSE

REEL TYPE

EXTINGUISHER/HOSE

REEL MOUNTING

-FE: FIRE EXTINGUISHER

-SR: SEMI-RECESSED CABINET

-BR: BRACKET MOUNTED

-HR: HOSE REEL

-SM: SURFACE MOUNT CABINET

-FR: FULLY RECESSED CABINET

HR:SM

WET-PIPE HOSE REEL

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

03/12/14 LS-011

LIFE SAFETY PLAN - BASEMENT

A. WHITENER

D. SCOTT

A. WHITENER

78794LS-011.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 BASEMENT LIFE SAFETY PLAN

UP

CP

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.452.9 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

2998.80 SF

ELECTROLESS

NICKEL

PLATING

32305.32 SF

NICKEL

PLATING

164.97 SF

PLC/FIRE

Redundant

Room

VAPOR

BLAST

ROOM

3716.89 SF

WATER

TREATMENT

146.94 SF

RESPIRATOR

CLEANING

128.10 SF

CORRIDOR

226'

178' 200'

142'CP:25'

145' - 11 1/2"

64'

119.63 SF

ELECTROLESS

NICKEL LAB

4A - 80BC 4A - 80BC

10A - 60BC

10A - 60BC40A - 80BC40A - 80BC

10A - 60BC

10A - 60BC

10A - 60BC

NORMALLY UNOCCUPIED

EQUIPMENT ACCESS

INDUSTRIAL 1 PERSON / 100 SQFT

0 PERSONS

NUMBER OF OCCUPANTS

ROOM NAME

AREA

CLEAR WIDTH

EXIT CAPACITY

OCCUPANTS SERVED

COMMON PATH

OF TRAVEL

TRAVEL

DISTANCE

EGRESS

PATH

COMMON PATH

TERMINATION

POINT

EXIT DOOR

REQUIRED WIDTH

36"

22"

44" 44"

NAME

XX

111SF

GENERAL NOTES

1. REFER TO ARCHITECTURAL LEGEND FOR ADDITIONAL

INFORMATION REGARDING SYMBOLS AND

ABBREVIATIONS.

2. REFER TO AG003 FOR LIFE SAFETY NARRATIVE AND

BUILDING CODE ANALYSIS.

3. REFER TO THE ELECTRICAL LIGHTING PLANS FOR

LOCATION OF EXIT SIGNS AND EMERGENCY

LIGHTING.

4. REFER TO THE FIRE SUPPRESSION AND ALARM PLANS

FOR LOCATION OF FIRE PROTECTION DEVICES.

5. FINAL LOCATIONS OF FIRE EXTINGUISHERS AND

HOSE REELS SHALL BE APPROVED BY THE AHJ PRIOR

TO INSTALLATION.

DOOR EGRESS TAG STAIR EGRESS TAG

ROOM OCCUPANCY TAG

EGRESS PATH

100'CP:666'

A:B:C: TYPE DRY CHEMICAL

4A-20B-C

PORTABLE FIRE EXTINGUISHERS AND HOSE REELS

FE:SR

EXTINGUISHER /HOSE

REEL TYPE

EXTINGUISHER/HOSE

REEL MOUNTING

-FE: FIRE EXTINGUISHER

-SR: SEMI-RECESSED CABINET

-BR: BRACKET MOUNTED

-HR: HOSE REEL

-SM: SURFACE MOUNT CABINET

-FR: FULLY RECESSED CABINET

HR:SM

WET-PIPE HOSE REEL

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

03/04/15 LS-012

LIFE SAFETY PLAN - OPERATING

FLOOR

A. WHITENER

D. SCOTT

A. WHITENER

78794LS-012.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 OPERATING FLOOR LIFE SAFETY PLAN

UP UP

UP

UP

CP

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.452.9 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

184' 166'

NORMALLY UNOCCUPIED

EQUIPMENT ACCESS

INDUSTRIAL 1 PERSON / 100 SQFT

0 PERSONS

NUMBER OF OCCUPANTS

ROOM NAME

AREA

CLEAR WIDTH

EXIT CAPACITY

OCCUPANTS SERVED

COMMON PATH

OF TRAVEL

TRAVEL

DISTANCE

EGRESS

PATH

COMMON PATH

TERMINATION

POINT

EXIT DOOR

REQUIRED WIDTH

36"

22"

44" 44"

NAME

XX

111SF

GENERAL NOTES

1. REFER TO ARCHITECTURAL LEGEND FOR ADDITIONAL

INFORMATION REGARDING SYMBOLS AND

ABBREVIATIONS.

2. REFER TO AG003 FOR LIFE SAFETY NARRATIVE AND

BUILDING CODE ANALYSIS.

3. REFER TO THE ELECTRICAL LIGHTING PLANS FOR

LOCATION OF EXIT SIGNS AND EMERGENCY

LIGHTING.

4. REFER TO THE FIRE SUPPRESSION AND ALARM PLANS

FOR LOCATION OF FIRE PROTECTION DEVICES.

5. FINAL LOCATIONS OF FIRE EXTINGUISHERS AND

HOSE REELS SHALL BE APPROVED BY THE AHJ PRIOR

TO INSTALLATION.

DOOR EGRESS TAG STAIR EGRESS TAG

ROOM OCCUPANCY TAG

EGRESS PATH

100'CP:666'

A:B:C: TYPE DRY CHEMICAL

4A-20B-C

PORTABLE FIRE EXTINGUISHERS AND HOSE REELS

FE:SR

EXTINGUISHER /HOSE

REEL TYPE

EXTINGUISHER/HOSE

REEL MOUNTING

-FE: FIRE EXTINGUISHER

-SR: SEMI-RECESSED CABINET

-BR: BRACKET MOUNTED

-HR: HOSE REEL

-SM: SURFACE MOUNT CABINET

-FR: FULLY RECESSED CABINET

HR:SM

WET-PIPE HOSE REEL

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

03/04/15 LS-013

LIFE SAFETY PLAN - MEZZANINE

A. WHITENER

D. SCOTT

A. WHITENER

78794LS-013.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 MEZZANINE LIFE SAFETY PLAN

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.4 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

BASEMENT

2'

- 6

1/ 2"

STAIR TYPE A

STAIR TYPE A STAIR TYPE A

STAIR TYPE B

STAIR TYPE B

STAIR TYPE A

C1 A-0400

B1 A-0400

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 A-0100

OVERALL PLAN - BASEMENT

A. WHITENER

D. SCOTT

A. WHITENER

78794A-0100.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 NEW WORK - BASEMENT

BASEMENT COATING SYSTEM:

CONCRETE FLOOR & STRUCTURAL STEEL: PROTECTIVE SYSTEM I-3

BOTTOM OF NEW METAL DECK CEILING: PROTECTIVE COATING SYSTEM M-2

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO

EACH PHASE OF CONSTRUCTION.

N

T-701 T-703

T-705 T-707

T-709 T-711

T-713 T-717

T-719 T-721

T-723 T-725

T-727 T-729

T-569 T-571

T-573

T-501 T-503

T-505 T-507

T-509 T-511

T-513 T-515

T-517 T-519

T-521 T-523

T-525 T-527

T-529 T-531

T-533 T-535

T-537 T-539

T-541

W

ET

B

LA

ST

T-471 T-473

T-429 T-431

T-305 T-309

T-307 T-301

T-303

R O

-2

T-251 T-253

T-255 T-257

T-259 T-261

T-263 T-265

T-267 T-269

T-271 T-273

T-275

R O

-1

C C

F-1 M

M F- 1

C

IP

-1

T-277 T-279

T-281 T-283

T-285

W S-1

T-205 T-207

T-209 T-211

T-213 T-215

T-217 T-219

T-221 T-223

T-225 T-227

T-231 T-229

T-233 T-235

T-203 T-201

T-237 T-239

T-101 T-103

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.452.9 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

ELECTROLESS

NICKEL PLATING

NICKEL PLATING

PLC/FIRE

WATER TREATMENT

RESPIRATOR

CLEANING

BID OPTION NO. 1

UP UP UP

UP

UP

NEW STAIR FROM

BASEMENT NEW STAIR FROM

BASEMENT

NEW STAIR FROM

BASEMENT

NEW STAIR FROM

BASEMENT

NEW STAIR FROM

BASEMENT

B5

Sim A-0114

A5

Sim A-0112

A5

Sim A-0112

CORRIDOR

NEW STAIR FROM

BASEMENT

NEW STAINLESS

STEEL GUARDRAIL

NEW STAINLESS

STEEL GUARDRAIL

SEE DETAIL A2 - TYP.

NEW STAINLESS

STEEL GUARDRAIL

NEW STAINLESS

STEEL GUARDRAILNEW STAINLESS

STEEL GUARDRAIL

BENT PLATE, DECK

AND CONCRETE

TOPPING RE: STRUC

1/8" STEEL PIPE.

PAINT EXTERIOR AND

LINE INTERIOR WITH

ASPHALT BASED PRIMER

8"

1'

- 9

1'

- 9

TYPE 304

STAINLESS

STEEL GUARDRAIL

1 - 1/4" DIAMETER.

PER ASTM A276

1" GALVANIZED

FASTENER

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 A-0110

OVERALL PLAN - OPERATING FLOOR

A. WHITENER

D. SCOTT

A. WHITENER

78794A-0110.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 NEW WORK - OPERATING FLOOR

OPERATING FLOOR COATING SYSTEM:

CONCRETE FLOOR & STRUCTURAL STEEL TO 4' - 0" AFF: PROTECTIVE SYSTEM F-8

STEEL ABOVE 4' - 0": PROTECTIVE COATING SYSTEM M-2

HOLLOW METAL DOORS & FRAMES: PROTECTIVE COATING M-2

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO

EACH PHASE OF CONSTRUCTION.

2. GUARDRAIL VERTICAL POSTS TO BE EQUALLY SPACED NO CLOSER THAN 8"

AND NO FURTHER THAN 4' - 0" APART. DO NOT PLACE VERTICAL POSTS IN

AREAS MARKED WITH BLACK BOX. COORDINATE WITH MECHANICAL FOR TANK

LOCATIONS AND ELECTRICAL FOR RECTIFIER CONTROL PANEL LOCATIONS.

N

0 4' 8' 16'

SCALE: 1 1/2" = 1'-0"A2 STAINLESS STEEL GUARDRAIL

LeLaKbKaJaIbIaHcHaGbG

56.3

55.7

55.1

54.5

53.9

53.9a

Ha.9 Ia.9 Ja.9 Kb.9

ELECTROLESS

NICKEL PLATING

NICKEL PLATING

PLC/FIRE

CORRIDOR

RESPIRATOR

CLEANING

104 102

1'

- 8

8'

- 6

20' - 0"

1'

- 6

BID OPTION NO. 1

INFILL DOOR OPENINGS

WITH METAL PANELS

REMOVED DURING

DEMOLITION.

EXISTING METAL PANELS

REMOVED DURING DEMOLITION

ON NEW 20 GA METAL STUDS

@ 24" O.C.

METAL WALL

PANEL ON 20GA

4" METAL STUDS

@ 16" O.C.

METAL WALL

PANEL ON 20GA

4" METAL STUDS

@ 16" O.C.

Sim A-0114

A-0112

ALIGN TO

SLAB EDGE

OVEN

MASKING

TABLE

MASKING

TABLE

CAX ORGANISOL

DRY MIX BUCKET

WASH

SALT SPRAYSINK

DESK LOCKERS

SINK

1' - 6"

56.3

EXISTING METAL

PANEL WALL

18 GA. BENT METAL PLATE -

FASTEN TO STUDS @ 24" O.C.

PAINT TO MATCH EXISTING WALL

4"

INFILL END OF

WALL CAVITY

WITH (2) STUDS

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 A-0112

AREA PLAN - OPERATING FLOOR -

AREA B

A. WHITENER

D. SCOTT

A. WHITENER

78794A-0112.DWG

D. SCOTT

SCALE: 1/4" = 1'-0"A5 OPERATING FLOOR - AREA A

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO EACH PHASE

OF CONSTRUCTION.

OPERATING FLOOR COATING SYSTEM:

CONCRETE FLOOR & STRUCTURAL STEEL TO 4' - 0" AFF: PROTECTIVE SYSTEM F-8

STEEL ABOVE 4' - 0": PROTECTIVE COATING SYSTEM M-2

HOLLOW METAL DOORS & FRAMES: PROTECTIVE COATING M-2

N

0 4' 8' 16'

SCALE: 1 1/2" = 1'-0"1 END OF WALL DETAIL - TYPICAL

LeLaKb

59.3

58.7

Kb.9

METAL WALL PANEL ON

20GA 4" METAL STUDS

@ 16" O.C.

ELECTROLESS

NICKEL LAB

A-0114

WET

BLASTER

HOODSINK

3"

9' - 3" 2' - 5 1/2"

11' - 8 1/2"

FLAT METAL PANEL

8" METAL JOIST (20 GA)

@ 16" O.C.FLAT METAL PANEL

4" METAL STUDS

(20 GA) @ 16" O.C.

FLASHING

FLASHING FLASHING BY METAL

PANEL MANUFACTURER

8"

8"

C3

Sim A-0600

9"

9"

SCALE: 1/4" = 1'-0"B5 OPERATING FLOOR-AREA D

BASIS OF DESIGN FOR METAL WALL PANELS

PROFILE SERIES, BY CENTRIA

1W - 30A - 20GA. SUBSTRATE G-90

HOT DIP GALVANIZED STEEL CONFORMING TO ASTM A924 + A653

STRUCTURAL QUALITY. FINISH COATING: VERSACOR ELITE PF

COATING SYSTEM

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE

RELATED TO EACH PHASE OF CONSTRUCTION. OPERATING FLOOR COATING SYSTEM:

CONCRETE FLOOR & STRUCTURAL STEEL TO 4' - 0" AFF: PROTECTIVE SYSTEM F-8

STEEL ABOVE 4' - 0": PROTECTIVE COATING SYSTEM M-2

HOLLOW METAL DOORS & FRAMES: PROTECTIVE COATING M-2

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 A-0114

AREA PLAN - OPERATING FLOOR -

AREA F

A. WHITENER

D. SCOTT

A. WHITENER

78794A-0114.DWG

D. SCOTT

N

0 4' 8' 16'

SCALE: 1/4" = 1'-0"1 TYPICAL ENCLOSURE SECTION

UP UP

UP

UP

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.452.9 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

FLAT METAL PANELS

ON 8" (20 GA) METAL

JOISTS @ 16" O.C.

FLAT METAL PANELS ON

8" (20 GA) METAL JOISTS

@ 16" O.C.

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 A-0120

OVERALL PLAN - MEZZANINE

A. WHITENER

D. SCOTT

A. WHITENER

78794A-0120.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 NEW WORK - MEZZANINE

MEZZANINE COATING SYSTEM:

STRUCTURAL STEEL, GRATING, AND HANDRAILS: PROTECTIVE COATING SYSTEM M-2

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO

EACH PHASE OF CONSTRUCTION.

N

62.361.661.160.5

Le

La

Kb

Ka

Ja

Ib

Ia

Hc

Ha

Gb

G

59.959.358.758.157.556.956.355.755.154.553.953.4 53.9a

Ha.9

Ia.9

Ja.9

Kb.9

NEW FIBERGLASS GRATING

OVER PLATFORM W/

GALVANIZED GUARDRAIL -

SEE DETAIL A3/A-0140

RE: STRUCTURAL FOR SIZE

PULTRUDED STAIR TREAD

PANEL - FIBERGLASS SPF,

YELLOW 1 - 1/2" BEARING

BARS, 1 - 1/2" O.C. REGULAR

CROSS BARS, 6" O.C.

YELLOW GRIT SURFACE,

INTERNAL NOSING; 11"

PANEL WIDTH.

RE: STRUC FOR DETAIL.

COVER AND PATCH EXISTING OPENING WHERE MECHANICAL

EQUIPMENT WILL NOT BE REPLACED. COORDINATE WITH

MECHANICAL AND STRUCTURAL. RE: DETAILS ON A-0500

3" 3"

7/8" MIN

HSS2x2x3/16 POST (GALV)

PAINT TO MATCH EXISTING

1'

- 9

1'

- 9

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA, OKLAHOMA

U.S. ARMY ENGINEER DISTRICT

CORPS OF ENGINEERS

SYMBOL REVISIONS DATE APPROVED

5 4 3 2 1

D

C

B

A A

B

C

D

C O

PY

R

IG

H

T

BU

RN

S

AN

D

M

CD

O N

N

EL

L

EN

G

IN

EE

RI

N G

C O

M

PA

N Y, I N

C.

W912BV-15-R0093

J. KLING

42x30

2/6/15 A-0140

OVERALL PLAN - ROOF

A. WHITENER

D. SCOTT

A. WHITENER

78794A-0140.DWG

D. SCOTT

SCALE: 1/8" = 1'-0"A5 NEW WORK - ROOF

GENERAL NOTES:

1. REFERENCE MECHANICAL PHASING DRAWINGS FOR SCOPE RELATED TO EACH

PHASE OF CONSTRUCTION.

2. REFERENCE MECHANICAL DRAWINGS FOR REQUIRED NEW PENETRATIONS

AND INFILL.

3. REFERENCE STRUCTURAL DRAWINGS FOR PLATFORM DEMOLITION.

4. REFERENCE SHEET A0500 FOR ROOFING AND PENETRATION DETAILS.

5. ALL OPENINGS SHALL BE ENCLOSED AT THE END OF EACH WORKING DAY.

6. WELDING IS BY PERMIT ONLY. ALL FIRE SAFETY PROVISIONS WILL BE

FOLLOWED. A FIRE EXTINGUISHER OF THE CORRECT TYPE WILL BE ADJACENT

TO WORK ON THE ROOF AT ALL TIME.

7. AFTER EXISTING ROOFING, SHEATHING & INSULATION HAS BEEN REMOVED,

CONTACT THE CONTRACTING OFFICER TO INSPECT THE EXISTING ROOF DECK.

SCOPE NOTES:

1. PATCHING AND REPAIRING DECK AND ROOF TO BE COMPLETED WITH

REMOVAL OF ALL EQUIPMENT AND PLATFORMS AS PART OF BASE BID.

2. MODIFY OR REPLACE EXISTING FRAMING AND GRATING AS REQUIRED TO

ACCOMMODATE NEW EQUIPMENT, DUCTWORK OR ROOFING ACCESS . GENERAL

CONTRACTOR TO COORDINATE.

3. REROOF OF ENTIRE PLATING SHOP AREA TO BE COMPLETED AS PART OF BID

OPTION NO. 2.

N

0 4' 8' 16'

SCALE: 1 1/2" = 1'-0"A3 GALV GUARDRAIL

Ha

T

RE

AD

S

3' - 10"

C3 A-0400

C3 A-0400

13 TREADS @ 11"

R

IS

ER

S

7"

CHANNEL

BOLTED ON TREADS

B4 A-0400

D4 A-0400

11' - 0"

4'-0" O.C. MAX TYP.

Gb

B3 A-0400

B3 A-0400

3' - 10"

T

RE

AD

S

13 TREADS @ 11"

R

IS

ER

S

7"

C4 A-0400

11' - 0"

1" GRATING TREADS

W/ ABRASIVE NOSING

BOLTED TO

STRINGER.

8" STEEL BEAM

- SEE

STRUCTURAL

1/4

2-1/2" CONC.

SLAB ON 1-1/2"

COMPOSITE

DECK.

TREAD

RISER

1" GRATING TREADS

W/ ABRASIVE NOSING

BOLTED TO STRINGER.

1/4" CHECKERED

PLATE NOSING

3/16

3 SIDES

L4x4x1/4x0'-6" EA

STRINGER W/ (2) 3/4"

DIA EPOXY ANCHOR

TREAD

RISER

3/16

TOC

3 SIDES

1" GRATING TREADS

W/ ABRASIVE NOSING

L4x4x1/4x0'-6" EA STRINGER

W/ (1) 3/4" DIA EPOXY ANCHOR

1-1/2" NOM. SCHED.

40 PIPE (PAINT)

3/16TYP.

C12X20.7 STAIR STRINGER (GALV.)

TREAD

RISER

1:1

BLDG 3001 PLATING SHOP RENOVATIONS

TINKER AIR FORCE BASE

OKLAHOMA CITY, OKLAHOMA

FY:15

DESIGNED BY:

DRAWN BY:

CHECKED BY:

REVIEWED BY:

SUBMITTED BY:

PLOT SCALE:

DATE:

FILE NUMBER:

SHEET

IDENTIFICATION

SOLICITATION NO.:

CONTRACT NO.:

SIZE:

BURNS & MCDONNELL

9400 WARD PARKWAY

KANSAS CITY, MO 64114

US Army Corps of Engineers ofSheet

TULSA,…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .