793-D780-01_ALARM_MONITORING_CONTROL_SYSTEM_OVERVIEW.pdf
PDF 186 KB Posted
- Attached to
- Liberty and Ellis Island Vessel 3101
- Solicitation number
- W912BU18B0013
About this file
793-D780-01 ALARM_MONITORING_CONTROL SYSTEM OVERVIEW
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Bid_Abstract_W912BU18B0013_SF_1409.pdf | ||
| Amendment_0005.pdf | ||
| Amendment_0004.pdf | ||
| 3101_Section_H_Updated_17_Aug_2018.DOCX | DOCX document | |
| Amendment_0003.pdf | ||
| W912BU18B0013_As_Amended_Through_Amendment_0003.pdf | ||
| 3101_Section_C_Updated_17_Aug_2018.docx | DOCX document | |
| 3101_Section_C_Updated_8-10-2018.docx | DOCX document | |
| 397-D730-02_LIGHTING_PLAN.pdf | ||
| Amendment_0002.pdf | ||
| 397-D730-01_LIGHTING_PLAN_-OUTBOARD_PROF.pdf | ||
| 826-B445-01_RD_Fire_&_Safety_Plan.pdf | ||
| 793-D725-01_CABLE_SCHEDULE_VOLTAGE_DROP_AC.pdf | ||
| W912BU18B0013_Amendment_0001.pdf | ||
| Contract_Drawings.7z | 7Z file | |
| Reference_Drawings.7z | 7Z file | |
| W912BU18B0013.pdf |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
793-D780-01
Revision - 2 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2
602 Main Diesel Engines Alarm, Control & Monitoring Panel (Manufacturer Supply, CAT MECP I for local; 1 Color MPD for both engines remote) Horn and light installed in Engine Room for alarm notification
Local at MDE, Inbd Side ECR Pilothouse
High Exhaust Stack Temperature Alarm ECR - - Low Starting Air Pressure Alarm ECR - - Low Level in Expansion Tanks ECR - - High Jacket Water Temperature ECR
DELETE Fuel Lift Pump Loss Pressure ECR DELETE Fuel Lift Pump Run Indication ECR
Engine Trouble Alarm ECR Lube Oil Pressure Alarm ECR
605 Z-Drives Alarm, Control & Monitoring Panel (Manufacturer supply for local and remote; 1 panel for each unit) Horn and light installed in Engine Room for alarm notification
Local at Z-Drive, Fwd or Inbd Side
ECR Pilothouse
Z-Drive Trouble Alarm Engine Room Backup Steering HPU Low Oil Level ECR Pilothouse Backup Steering HPU High Reservoir Temperature ECR Pilothouse
630 Fuel Oil System STBD Fuel Oil Tank: Low Low Level Alarm (10%) / Audible & Visual ECR - - STBD Fuel Oil Tank: Low Level Alarm (25%) / Audible & Visual ECR - - STBD Fuel Oil Tank: High Level Alarm (90%) / Audible & Visual ECR Fueling Locker - STBD Fuel Oil Tank: High High Level Alarm (95%) / Audible & Visual ECR Fueling Locker -
Port Fuel Oil Tank: Low Low Level Alarm (10%) / Audible & Visual ECR - - Port Fuel Oil Tank: Low Level Alarm (25%) / Audible & Visual ECR - - Port Fuel Oil Tank: High Level Alarm (90%) / Audible & Visual ECR Fueling Locker - Port Fuel Oil Tank: High High Level Alarm (95%) / Audible & Visual ECR Fueling Locker -
FWD Fuel Oil Day Tank Low Low Level Alarm (10%) / Audible & Visual ECR Pilothouse - FWD Fuel Oil Day Tank Low Level Alarm (25%) / Audible & Visual ECR Pilothouse - FWD Fuel Oil Day Tank High Level Alarm (90%) / Audible & Visual ECR - - FWD Fuel Oil Day Tank High High Level Alarm (95%) / Audible & Visual ECR - -
Eng Rm Fuel Oil Day Tank Low Low Level Alarm (10%) / Audible & Visual ECR Pilothouse - Eng Rm Fuel Oil Day Tank Low Level Alarm (25%) / Audible & Visual ECR Pilothouse - Eng Rm Fuel Oil Day Tank High Level Alarm (90%) / Audible & Visual ECR - - Eng Rm Fuel Oil Day Tank High High Level Alarm (95%) / Audible & Visual ECR - -
630 DELETE STBD Main Engine Fuel Lift Pump: Pressure Loss Alarm ECR Pilothouse - DELETE Port Main Engine Fuel Lift Pump: Pressure Loss Alarm ECR Pilothouse - DELETE Generator Engine #1 Fuel Lift Pump: Pressure Loss Alarm ECR Pilothouse - DELETE Generator Engine #2 Fuel Lift Pump: Pressure Loss Alarm ECR Pilothouse -
635 Service Oil Systems Hydraulic Oil Tank High Level Alarm (90%) / Audible & Visual ECR STBD Fill Locker - Lube Oil Tank High Level Alarm (90%) / Audible & Visual ECR STBD Fill Locker - Gear Oil Tank High Level Alarm (90%) / Audible & Visual ECR STBD Fill Locker -
ALARMS
Revision - 3 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2
ALARMS
637 Waste Oil System Waste Oil Tank High Level Alarm (90%) / Audible & Visual ECR Engine Room - 662 Oily Bilge System Oily Bilge Tank High Level Alarm (90%) / Audible & Visual ECR - -
OWS Oil Content Measuring/Monitor (> 15ppm) / Audible & Visual Local at Equipment ECR - 665 Pot Water System Potable Water Tank Low Low Level Alarm (10%) / Audible & Visual ECR - - 667 Swg/Santry System STBD Greywater Holding Tank: High Level Alarm (90%) / Audible & Visual ECR - -
Port Greywater Holding Tank: High Level Alarm (90%) / Audible & Visual ECR - - Sewage Holding Tank: High Level Alarm @ 90% / Audible & Visual ECR - - MSD High Level Alarm (95%) / Audible & Visual Local at Equipment ECR -
677 Fixed Fire Ext System Discharge Alarm, Sounds for 30 seconds after activation. CO2 discharge at the end of 30 second alarm.
Engine Room - -
678 Fire Detection System
Fire Detection & Alarm System, including CO detection for all enclosed occupied spaces: Min 6 Zones (Each deck level, with Engine Room Separate)
ECR Pilothouse -
Fire Alarm Activation Indicator Light (Red) Pilothouse Top Engine Room - 706 Batteries Battery Charger Monitor & Alarm, IAW ABS River Rules (2008) 7.19.4(4) Local at Charger
(Various Locations)
ECR -
24VDC Pilothouse Battery Charger 12VDC Pilothouse Battery Charger 24VDC Engine Room Battery Charger Emergency Lighting 12VDC Charger Generator Battery Charger
730 Navigation Lights Navigation Light, Bulb Out Alarm: On Navigation Panel / Audible & Visual Pilothouse - - 733 Generator Sets Alarm, Control & Monitoring Panel (Manufacturer Supply, CAT Series 1200 for local; 1 Color MPD for both engines remote) Local at SSDG ECR Pilothouse
Engine Overspeed Alarm: Audible & Visual Local at SSDG ECR - Low Lube Oil Pressure Alarm: Audible & Visual Local at SSDG ECR - High Jacket Water Temperature Alarm: Audible & Visual Local at SSDG ECR - Low Starting Battery Voltage Alarm (One Generator Set Only): Audible & Visual Local at SSDG ECR - Mechanical Gauges (see Clause C733) Local at SSDG - - High Exhaust Stack Temperature Alarm ECR - - Low Starting Air Pressure Alarm ECR - - Low Level in Expansion Tanks ECR - - Generator Automatic Shutdown for Overspeed - - - Generator Automatic Shutdown for Low Lube Oil Pressure - - - Generator Automatic Shutdown for High Jacketwater Temperature - - -
DELETE Loss Pressure to Fuel Lift Pump ECR 740 Switchboard Switchboard Controls & Indicator Lights Local at Switchboard in ECR - - 780 General Alarm General Alarm: Contact Maker Pilothouse ECR Fwd Main Dk BHD
General Alarm Bell & Lights as follows: - - - Hold Deck - Storage Space - bell and light - - - Hold Deck - Pump Room - bell and light - - - Hold Deck - Tank Room - bell and light - - -
Revision - 4 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2
ALARMS
780 General Alarm (cont.) Main Deck - Engine Room – bell and light - - - Main Deck - Engineers Control Room - bell - - - Main Deck - Engineers Quarters - bell - - - Main Deck - Galley/Mess - bell - - - Main Deck - STBD Exterior - bell - - - Main Deck - Port Exterior - bell - - - Main Deck - Fwd Exterior - bell - - - Upper Deck - Passage Way - bell - - - Upper Deck - Aft Exterior - bell - - - Texas Deck - Captains Quarters - bell - - - Texas Deck - Office - bell - - - Texas Deck - Electronics Room - bell - - - Pilot House - bell - - -
780 Bilge Alarm Bilge Alarm for the following spaces and compartments / Audbile & Visual ECR Pilothouse - Innerbottom Void STBD - - - Innerbottom Void Port - - - Tank Room STBD - - - Tank Room Port - - - Pump Room Fwd STBD - - - Pump Room Aft Port - - - Void #1S - - - Void #1P - - - Storage Room - - - Void #2S - - - Void #2P - - - Void #3S - - - Void #3P - - - Void #3C - - - Void #4S - - - Void #4P - - - Void #4C - - - Void #5S - - - Void #5P - - - Bilge Alarm Activation Indicator Light (Yellow) Pilothouse Top - -
Revision - 5 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2
ALARMS
780 WT Doors WT Door Open Alarm w/60 Second Activation Delay ECR - Audbile & Visual Pilothouse - Visual Only - W.T. Door #1 FR 20 - - W.T. Door #2 FR 29 - - W.T. Door #3 FR 27P - - W.T. Door #4 FR 27S - - W.T. Door #5 FR 34 - - W.T. Door #6 FR 33P - - W.T. Door #7 FR 33S - -
780 PH Alerter System Pilothouse Alerter System Pilothouse ECR STATE ROOM/CABINS 780 Loss of Pwr Alarm Loss of Power Alarm Activation Indicator Light (White/Clear) Pilothouse Top - -
Revision - 6 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2 Remote Location #3
317 DELETE Folding Mast Winch: Push Button Controls TBD may be Deleted DELETE DELETE - - 415 Windows Wiper Controls, Independent for Each Wiper (Wynn 1000 Series Controller): Start/Stop Pilothouse - - -
Electric Heat Trace WindowS: Automatic Temp Control, Integrated w/Window Pilothouse - - - Window Washer System for Each Window: Push On, separate system Pilothouse - - - Electric Window Fans: On/Off at Each Fan Pilothouse - - -
445 Rescue Skiff Outboard Motor: Start/Stop Skiff Center Console - - - Outboard Motor: Steering Skiff Center Console - - -
455 Crane Crane Power Pack: Start/Stop Controls Upper Deck at Crane - - - Crane: Operation Controls, Fixed On Crane Pedestal - - -
456 Winches & Capstan Deck Winch (x4): Push Button Controls Local at Each Winch Pilothouse - - Capstan: Push Button Controls Fwd Main Dk BHD Pilothouse - -
602 Main Diesel Engs Alarm, Control & Monitoring Panel (CAT MECP I for local; 1 Color MPD for both Engs remote)
Local at MDE, Inbd Side ECR Pilothouse -
Eng Start/Stop Local at MDE, Inbd Side ECR Pilothouse - Emergency Stop Local at MDE, Inbd Side ECR Pilothouse - Shaft Tachometers ECR Pilothouse - - Exhaust Stack Temperature ECR - - - Starting Air Pressure ECR - - - Eng Automatic Shutdown for Overspeed - - - - Lube Oil Pressure ECR
605 Z-Drives Alarm, Control & Monitoring Panel (Manufacturer Supply for local and remote;
1 panel for each unit)
Local at Z-Drive, Forward or Inbd Side
ECR Pilothouse -
Electric Operational Controls with Main Eng Controls Integrated, Full Follow-Up and Non-Follow-Up Options
ECR Pilothouse Local at Z-Drive, Forward or Inbd Side
630 Fuel Oil System Stbd Fuel Oil Tnk Sight Glass (GEMS SURE SITE) At Tnk - - - Port Fuel Oil Tnk Sight Glass (GEMS SURE SITE) At Tnk - - - Fwd Day Fuel Oil Tnk Sight Glass (GEMS SURE SITE) At Tnk - - - Eng Rm Day Fuel Oil Tnk Sight Glass (GEMS SURE SITE) At Tnk - - - Stbd Fuel Oil Tnk Lvl Indicating System (Electronic in soundings and gal) ECR - - - Port Fuel Oil Tnk Lvl Indicating System (Electronic in soundings and gal) ECR - - - Fwd Day Fuel Oil Tnk Lvl Indicating System (Electronic in soundings and gal) ECR Pilothouse - - Eng Rm Day Fuel Oil Tnk Lvl Indicating System (Electronic in soundings and gal) ECR Pilothouse - - Fuel Oil Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Fueling Locker - - Fuel Oil Transfer Pump: Run Indicating Light ECR - - - Fuel Oil Transfer Pump: E-Stop Stbd Towknee, Inbd Face Pump Rm - - Fuel Oil Transfer Hose Reel Controls Fueling Locker - - - Mn Eng Rm Day Tk Supply Pump: Start/Stop Auto Controlled with Eng Rm Day Tk ECR - - - Mn Eng Rm Day Tk Supply Pump: Run Indicating Light ECR - - - Bypass Eng Rm Day Tk Sply Pump: Start/Stop Auto Controlled with Eng Rm Day Tk ECR - - - Bypass Eng Rm Day Tk Sply Pump: Run Indicating Light ECR - - - Mn Eng Rm Day Tk Supply Pump: Start/Stop Manual Control at Pump Tnk Rm - - -
MONITORING AND CONTROLS
Revision - 7 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2 Remote Location #3
MONITORING AND CONTROLS
630 Fuel Oil Sys (cont) Mn Eng Rm Day Tk Supply Pump: Run Indicating Light at Pump Tnk Rm - - - Bypass Eng Rm Day Tk Supply Pump: Start/Stop Manual Control at Pump Tnk Rm ENG RM @ TANK - - Bypass Eng Rm Day Tk Sply Pump: Run Indicating Light at Pump Tnk Rm ENG RM @ TANK ECR - Fuel Oil Separator: Start/Stop Local at Equipment - - - Fuel Oil Separator: Indicating Light ECR - - - Stbd Fuel Oil Tnk: Shut-Off Valve Local at Valve CO2 Locker Fwd Main Dk BHD - Port Fuel Oil Tnk: Shut-Off Valve Local at Valve CO2 Locker Fwd Main Dk BHD - Fwd Day Fuel Oil Tnk: Shut-Off Valve Local at Valve CO2 Locker Fwd Main Dk BHD - Eng Rm Day Fuel Oil Tnk: Shut-Off Valve Local at Valve CO2 Locker Fwd Main Dk BHD - Stbd Supply Feed: Shut-Off Valve Local at Valve CO2 Locker Fwd Main Dk BHD - Port Supply Feed: Shut-Off Valve Local at Valve CO2 Locker Fwd Main Dk BHD - Stbd Main Eng Flow-Scan Fuel Meter/Readings Pilothouse ECR - - Port Main Eng Flow-Scan Fuel Meter/Readings Pilothouse ECR - - Generator Set #1 Flow Scan Fuel Meter/Readings Pilothouse ECR - - Generator Set #2 Flow Scan Fuel Meter/Readings Pilothouse ECR - -
635 Service Oil Systems Hydraulic Oil Tnk Sight Glass (Kenco 9900) At Tnk - - - Lube Oil Tnk Sight Glass (Kenco 9900) At Tnk - - - Gear Oil Tnk Sight Glass (Kenco 9900) At Tnk - - - Hydraulic Oil Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Hose Reel in Eng Rm - - Hydraulic Oil Transfer Pump: Run Indicating Light ECR - - - Lube Oil Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Hose Reel in Eng Rm - - Lube Oil Transfer Pump: Run Indicating Light ECR - - - Gear Oil Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Hose Reel in Eng Rm - - Gear Oil Transfer Pump: Run Indicating Light ECR - - -
637 Waste Oil System Waste Oil Tnk Sight Glass (Kenco 9900) At Tnk - - - Waste Oil Collection Pump: Start/Stop/Run Indicating Light Local at Pump (Eng Rm) - - - Waste Oil Collection Pump: Run Indicating Light ECR - - - Waste Oil Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Stbd Cntnmnt Station - - Waste Oil Transfer Pump: Run Indicating Light ECR - - -
640 Eng, Gen & Z-Drive Cooling System
Stbd Z-Drive Cooling Pump: Start/Stop Automatic Controlled with Stbd MDE - - - -
Stbd Z-Drive Cooling Pump: Run Indicating Light ECR - - - Port Z-Drive Cooling Pump: Start/Stop Automatic Controlled with Port MDE - - - - Port Z-Drive Cooling Pump: Run Indicating Light ECR - - - Stbd Supplemental Cooling Pump: Start/Stop/Run Indicating Light Local at Pump - - - Stbd Supplemental Cooling Pump: Run Indicating Light ECR - - - Port Supplemental Cooling Pump: Start/Stop/Run Indicating Light Local at Pump - - - Port Supplemental Cooling Pump: Run Indicating Light ECR - - -
660 Blg & Blst Systems Ballast Tnk #1S Tnk Sight Glass (GEMS SURE SITE) Ballast Tnk #1P Tnk Sight Glass (GEMS SURE SITE) Ballast Tnk #2S Tnk Sight Glass (GEMS SURE SITE)
Revision - 8 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2 Remote Location #3
MONITORING AND CONTROLS
660 Blg & Blst (cont.) Ballast Tnk #2P Tnk Sight Glass (GEMS SURE SITE) Bilge Pump: Start/Stop/Run Indicating Light Local at Pump - - - Bilge Pump: Run Indicating Light ECR - - - Ballast Pump: Start/Stop/Run Indicating Light Local at Pump - - - Ballast Pump: Run Indicating Light ECR - - - Ballast Tnk #1S Tnk Lvl Indicating System (Electronic in soundings and gal) Local at Pump/Manifold ECR - - Ballast Tnk #1P Tnk Lvl Indicating System (Electronic in soundings and gal) Local at Pump/Manifold ECR - - Ballast Tnk #2S Tnk Lvl Indicating System (Electronic in soundings and gal) Local at Pump/Manifold ECR - - Ballast Tnk #2P Tnk Lvl Indicating System (Electronic in soundings and gal) Local at Pump/Manifold ECR - - Longitudinal Inclinometer Local at Pump/Manifold ECR - - Transverse Inclinometer Local at Pump/Manifold ECR - -
662 Oily Bilge System Oily Bilge Tnk Sight Glass (Kenco 9900) At Tnk - - - Oily Bilge Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Stbd Cntnmnt Station - - Oily Bilge Transfer Pump: Run Indicating Light ECR - - - OWS: On/Off Local at Equipment - - - OWS: Run Indicating Light ECCR - - -
665 Pot Water System Potable Water Tnk Sight Glass (GEMS SURE SITE) At Tnk - - - Potable Water Tnk Lvl Indicating System (Electronic in soundings and gal) ECR - - - Potable Water Transfer Pump: Start/Stop/Run Indicating Light Tnk Rm Stbd Cntnmnt Station - - Potable Water Transfer Pump: Run Indicating Light ECR - - - Hot Water Recirculating Pumps (x2): Start/Start Automatically Thermostatically Controlled
667 Swg/Santry System Stbd Gray Water Holding Tnk Sight Glass (Kenco 9900) At Tnk - - - Port Gray Water Holding Tnk Sight Glass (Kenco 9900) At Tnk - - - Raw Sewage Tnk Magnetic Tnk Level Indicating System At Tnk - - - MSD: On/Off Local at Equipment - - - MSD Sump Pump: Start/Stop Automatic Controlled with Level Switches - - - - MSD Sump Pump: Start/Stop Override Controls Local at Equipment - - - Greywater Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Stbd Cntnmnt Station - - Greywater Transfer Pump: Run Indicating Light ECR - - - Sewage Transfer Pump: Start/Stop/Run Indicating Light Local at Pump Stbd Cntnmnt Station - - Sewage Transfer Pump: Run Indicating Light ECR - - -
670 Tnk Sounding Tubes Ballast Tnk #1P Main Deck Fr 3 - - - Ballast Tnk #1S Main Deck Fr 3 - - - Ballast Tnk #2P Main Deck Fr 12 - - - Ballast Tnk #2S Main Deck Fr 12 - - - Fuel Oil Tnk, Stbd Fueling Locker, Inside - - - Fuel Oil Tnk, Port Fueling Locker, Inside - - - Greywater Tnk, Port Main Deck Fr 16 - - - Greywater Tnk, Stbd Main Deck Fr 16 - - - Raw Sewage Tnk Main Deck Fr 20 - - -
Revision - 9 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2 Remote Location #3
MONITORING AND CONTROLS
Cooler Void, Port Main Deck Fr 23 - - - Cooler Void, Stbd Main Deck Fr 23 - - -
675 Firemain System Fire Pump: Start/Stop/Run Indicating Light Local at Pump ECR Pilothouse Fwd Main Dk BHD Fire Stations at the following locations (local firemain branch valve only): - - - - Fire Station #1 - Eng Rm - - - - Fire Station #2 - Main Deck Frame 18 Port - - - - Fire Station #3 - Main Deck Frame 18 Stbd - - - - Fire Station #4 - Main Deck Frame 33 Port - - - - Fire Station #5 - Main Deck Frame 43 Stbd - - - - Fire Station #6 - Upper Deck Frame 15 Port - - - - Fire Station #7 - Upper Deck Frame 15 Stbd - - - - Fire Station #8 - Texas Deck Frame 15 Port - - - - Fire Station #9 - Texas Deck Frame 15 Stbd - - - -
677 Fixed Fire Ext System
CO2 Activation/Pulls Local in CO2 Locker Outside CO2 Locker Fwd Main Dk BHD -
678 Fire Detection System
Fire Det & Alarm System, including CO detection for all enclosed occupied spaces, Min 6 Zones (Each deck level, with Eng Rm Separate): Panel
ECR Pilothouse Fwd Main Dk BHD -
685 HVAC - Air Handlers System Controller (Mitsubishi Electric TC-24) ECR - - - Cassette Unit Controller (1 per controller) At Cassette/Space Served - - - Air Handler Unit Automatic Shutdown Linked to Fire Alarm Zone Activation - - - - Air Handler Units (All) & Condenser Units (All) Automatic Shutdown Linked to CO2 Activation
685 HVAC - Head Exhaust Fans
Fan: On/Off Wall Switch in Each Head - - -
Head Exhaust Fan Automatic Shutdown Linked to Fire Alarm Zone Activation - - - - Head Exhaust Fan Automatic Shutdown Linked to CO2 Activation - - - -
685 HVAC - Electric Heaters
Heater: On/Off w/Thermostatic Control At Heater/Space Served - - -
Head Exhaust Fan Automatic Shutdown Linked to Fire Alarm Zone Activation - - - - Head Exhaust Fan Automatic Shutdown Linked to CO2 Activation - - - -
685 HVAC - Ventilation Fans
Supply Fans & Exhaust Fans (Eng Rm): On/Off w/Variable Speed Controller Eng Rm - - -
Supply Fans & Exhaust Fans (Eng Rm) Automatic Shutdown Linked to CO2 Activation
Supply Fans & Exhaust Fans (Storage Rm, Pump Rm & Tnk Rm) In Each Respective Space - - - Supply Fans & Exhaust Fans (Storage Rm, Pump Rm & Tnk Rm) Automatic Shutdown Linked to Fire AlaRm Zone Activation
Emergency Stops for All Supply Fans & Exhaust Fan ECR Outside CO2 Locker Fwd Main Dk BHD -
Revision - 10 of 10
WBS System / Equipment
Description Primary Location Remote Location #1 Remote Location #2 Remote Location #3
MONITORING AND CONTROLS
685 HVAC - Louver Motors
Louver Actuator Motor - Open/Close:
Linked to Respective Supply/Exhaust Fan On/Off
Louver Actuator Motor - Closed Position: Default Position, Loss of Power Position - - - - Stack Louver Motor - Open/Close:
Linked to Eng Rm Exhaust Fan on Respective Side
Stack Louver Actuator Motor - Closed Position:
Default Position, Loss of Power Position
690 Cmprsd Air System Main Compressors (x2): On/Off Automatic Pressure Controlled - - - - Air Horn Compressor (x2): On/Off Automatic Pressure Controlled - - - -
706 Batteries Battery Charger Monitor & Alarm, IAW ABS River Rules (2007) 4-5-4/7.19.4(e) Local at Charger (Various Locations)
ECR - -
730 Lights Search Light (x2): On/Off with Distant Electric Controls Pilothouse - - - Navigation Lights: On/Off Pilothouse - - - Exterior Lights: On/Off Pilothouse - - - Flood Lights: On/Off Pilothouse - - -
733 Generator Sets Alarm, Control & Monitoring Panel (Manufacturer Supply, CAT Series 1200 for local; 1 Color MPD for both Engs remote)
Local at SSDG ECR Pilothouse -
Generator Start/Stop Local at SSDG - - - Emergency Stop Local at SSDG ECR Pilothouse - Exhaust Stack Temperature ECR - - - Starting Air Pressure ECR - - - Starting Battery Voltage Local at SSDG ECR - Mechanical Gauges (see Clause C733) Local at SSDG - - - Generator Automatic Shutdown for Overspeed - - - - Generator Automatic Shutdown for Low Lube Oil Pressure - - - - Generator Automatic Shutdown for High Jacket Water Temperature - - - -
740 Switchboard Switchboard Controls & Indicator Lights Local at Swtchbd in ECR - - - Loss of Power Light Pilothouse Top
770 Nav Equipment Night Vision Camera: On/Off with Electric Pan, Tilt and Zoom Controls Pilothouse - - - Air Horn: Push Button Control (Kahlenberg M-511C Controller) Pilothouse - - - Air Horn: Automatic Programmed Signals (Kahlenberg M-511C Controller) Pilothouse - - - Air Horn: Manual Valve Pull Pilothouse Overhead - - -
780 WT Doors WT Door Open/Close Indicator ECR Security & Digital Visual Monitoring
Cameras for Eng Rm, Pump Rm, Tnk Rm, and Exterior Monitors Office ECR Pilothouse
| 793-D780-01 Rev - Alarm Monitoring Control System Overview |
| 793-D780-01 Rev - ALARM MONITORING CONTROL SYSTEM OVERVIEW |
| Alarms |
| Monitoring & Control |
File details come from the government source that posted it.