C-5-M Formal Training Unit Facility, Dover Air Force Base, Dover, Delaware
Solicitation number
W912BU12R0002
Issued by

About this file

Amendment Number 0003 - Specifications

View the file

Other files

File Type Posted
12R0002-DWGS-AM8.PDF PDF
12R0002-SPECS-AM8.PDF PDF
12R0002-SPECS-AM7.PDF PDF
12R0002-DWGS-AM7.PDF PDF
Amendment6.pdf PDF
12R0002-SPECS-AM5.PDF PDF
12R0002-SPECS-AM4.PDF PDF
12R0002-DWGS-AM4.PDF PDF
12R0002-DWGS-AM3.PDF PDF
Site Visit Attendees.pdf PDF
11R0002-SPECS-AM2.PDF PDF
Amendment 0001.pdf PDF
12R0002_C-5M_Dwgs.pdf PDF
12R0002_C-5M_Specs_Volume 1.pdf PDF
RFI Example.xls XLS spreadsheet
12R0002_C-5M_Specs_Volume 2.pdf PDF
Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment your desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 10-83)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION

NO.

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NO.

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended, is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER NO.

IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

NSN 7540-01-152-8070

Previous edition unusable

Design and Construct a C-5M Formal Training Unit Facility, Dover Air Force Base, Dover, Delaware

THIS AMENDMENT DOES NOT EXTEND THE PROPOSAL DUE DATE OF 31 JANUARY 2012 AT 4:00 PM.

The cut off date for Requests for Information (RFI) is 18 January 2012 at 3:00 P.M. If RFI's are received after this date, they may not be addressed.

Continued on next page

US Army Engineer District, Philadelphia Wanamaker Building, 100 Penn Square East Philadelphia, Pennsylvania 19107-3390

US Army Engineer District, Philadelphia Attn: Michelle Bertoline Wanamaker Building, 100 Penn Square East Philadelphia, Pennsylvania 19107-3390

W912BU-12-R-0002

01/13/2012

11/14/2011

This page was intentionally left blank for duplex printing.

Amendment No. 0003

RFP W912BU-12-R-0002

14. DESCRIPTION OF AMENDMENT (continued)

a. RFIs with RESPONSES: RFIs with responses, annotated Amendment No. 0003 are attached to this amendment.

b. SPECIFICATIONS:

(1) Section 00120 – PROPOSAL SUBMISSION REQUIREMENTS, EVALUATION CRITERIA AND BASIS OF AWARD: Please delete Section 00120 in its entirety and substitute revised section 00120, annotated Amendment No. 0003, attached hereto.

(2) Section 00815 – WAGE RATES: Please delete Section 00815 in its entirety and substitute revised section 00815, annotated Amendment No. 0003, attached hereto.

(3) Section 01 10 00 – STATEMENT OF WORK: Please delete section 01 10 00 in its entirety and substitute revised section 01 10 00, annotated Amendment No.

0003, attached hereto.

(4) Section 01 33 16 – DESIGN AFTER AWARD: Please delete pages 01 33 16-6, 8 and 19 in their entirety and substitute revised pages 01 33 16-6, 8 and 19, annotated Amendment No. 0003, attached hereto.

(5) Section 01 33 29 – LEED DOCUMENTATION: Please delete section 01 33 29 in its entirety and substitute revised section 01 33 29, annotated Amendment No.

0003, attached hereto.

(6) Section 01 35 26 – GOVERNMENTAL SAFETY REQUIREMENTS: Please delete page 01 35 26-7 in its entirety and substitute revised page 01 35 26-7, annotated Amendment No. 0003, attached hereto.

(7) Section 01 80 00 – COMMISSIONING: Please delete page 01 80 00-3 in its entirety and substitute revised page 01 80 00-3, annotated Amendment No.

0003, attached hereto.

(8) Appendix C – LEED PROJECT CHECKLIST: Please delete Appendix C in its entirety and substitute revised Appendix C, annotated Amendment No. 0003, attached hereto.

c. CONTRACT DRAWINGS:

(1) Please delete drawings A101, CL101 and CL102 in its entirety and substitute revised drawings of the same number, with the latest revision date of 10 Jan 2012, attached hereto.

d. Please indicate receipt of this amendment on Standard Form 1442 (SOLICITATION, OFFER, AND AWARD) as Amendment No. 0003. Failure to acknowledge all amendments may be cause for rejection of the offer.

This page was intentionally left blank for duplex printing.

W912BU-12-R-0002

FOR INFORMATION ONLY

REQUESTS FOR INFORMATION WITH RESPONSES

Solicitation No. W912BU-12-R-0002 13-Jan-2012

RFI # Discipline Dwg Sheet/Spec Section Comment Response

47 Earthwork Spec Volume #2, Appendix A

In regard to earthwork for preparation of the site, there appears to be multiple boring reports and maps provided in the Specifications Volume #2.

Page 7 of 190 of the Volume 2 spec (Appendix A), is a Demolition Plan titled CD103. This sheet indicates 11ea borings, and is dated 12/15/05, by Tetra Tech Inc. Following this is a report by Hunt Engineering, dated October 12, 2009, starting on page 11 of 190, of the volume. This report indicates that 6ea borings were taken, and recommended undercutting 13.5’ deep, under the proposed building (the building being proposed in that report --- not the building which is part of this project). Following this report is another boring map, on page 22 of 190 of the volume, titled “Boring Location Plan” and dated 2009-10-06. It appears that these borings were taken to the western part of the proposed building site, per sheet CL101, with north being the upper right of the page. We think that the second boring map and the first geotechnical report (dated 10/12/09) go together.

Following the second boring map, is a second geotechnical report from Hunt Engineering, dated March 30, 2010. This report references 5ea borings, of which there is no map for.

This geotechnical report does not recommend any over-excavation requirements. We understand that as a part of this proposal, we are to include a geotechnical investigation.

However, it would be disadvantageous to the owner for bidders to assume that we will be required to undercut the proposed pad by 13.5’, when in fact, it may not be required.

The cost to remove and replace could be in the range of $150,000-$175,000. Can a unit price be used for removal and replacement of soil, should the geotechnical investigation call for it?

Revised Answer: In Vol 2, page 14 of 190, App A, the Hunt Engineering Report, second para of para 6.a.

states: 'The ground improvement shall consist of over-excavating the existing soil below the proposed footings and 2-feet outside the footing footprint to an ELEVATION of 13.5-feet and then backfilling the resulting excavation with properly compacted soil meeting the criteria of load-bearing fill, as defined in Section 7a. As an alternative, modified stone with fines, such as PennDOT 2RC and AASHTO #57 stone may be used to backfill the over-excavation.' For bid purposes, the only overexcavation required is 2 feet around the footings."

65 Electrical General Is there an existing building management system? No.

66 Experience

Shoule we assume that the Prime Contractor and any key subcontractors experience are included in the total 3 projects?

Please see the last sentence of Para 4.1.a (1st paragraph) of Section 00120.

67 Design all drawings Can all drawings be issued as CAD files to aid in design process? These will be provided after award.

68 Mechanical

In order to provide Leed credits would a closed loop, vertical bore geothermal system be a permitted option? If so, are there any restrictions regarding the geothermal boreholes?

Yes. Unless the RFP including any referenced material prohibits a specific system, it is the Offeror's decision to select the system.

69 Architectural 01 10 00 Para 3.6.15 Vestibule: Door path to be fitted with power assists for operation by the disabled. Define "power assists". Please see Amendment No. 0003.

Request for Proposal Solicitation Form 1442

Item 13B indicates a bid guarantee is required; however, no percentage is indicated

The Bid Guarantee Amount can be found in FAR Clause 52.228-1 in Section 00700 .

71 Design Spec Section 01 10 00 Statement of Work

Paragraph 5.10.1.2. indicates the contractor shall provide the services of a qualified regeristered fire protection engineer. Is this necessary since there is no fire sprinkler system in the building?

Yes, placement of heat detectors and fire alarm design, etc requires FPE oversight. Bid as indicated.

Request for Proposal Amendment No. 0001

Special Clause SC-1 indicates the Base Bid completion to be 540 calendar days. What amount of time should be alloted for the Government's representative to review bid documents?

Contract duration starts from Contractor's receipt of Notice to Proceed, which is after Govt's review of bid documents.

W912BU-12-R-0002

73 Electrical Statement of Work Section

6.10.7 vs 6.9.2.3

Section 6.10.7 refers to a switchboard; Section 6.9.2.3. states an estimated load of 225A. Please confirm if a switchboard is required in lieu of a service entrance panelboard for a 225A service? Please see Amendment No. 0003.

74 Electrical Statement of Work Section 6.9.2.3

Please confirm if a wye-wye connected transformer is required in lieu of a typical delta-wye configuration. Please bid as shown.

75 Electrical Statement of Work Section 6.9.2.3

Will the new transformer be oil-filled or dry type? If oil, what will the requirement be for containment?

Oil vs dry is up to the Designer. No containment is required, per the UFC for Exterior ELectrical Power Distribution.

76 Civil

Will profile drawings be required for duct banks? If so, are locations of existing underground utilities and structure known?

See Paras 4.8.2, 4.8.3 and 4.8.4 of Section 01 33 16.

77 Electrical Statement of Work Section 6.9.2.3

Please identify location of existing switch installed with Phase 1 facility. Drawings included with the PFP do not show the switch location. See Amendment No. 0003.

78 Civil Reference Drawings CL

Please confirm type,size,and number of conduits in radar duct bank to be relocated. Please see Note 5 on Dwg CL101.

79 Civil Reference Drawings CL

Please confirm type,size,and number of conduits in telephone line to be relocated. See Amendment No. 0003.

80 Electrical Will Dover AFB Provide available short circuit information at service connection point for use in required studies? Yes.

81 Electrical Statement of Work Section 6.10.13

Please confirm if there is an existing cathodic protection system that will be extended as part of this work.

There is not an existing cathodic protection system.

General Requirements 01 45 04 / 00 12 00

Section 001200, Page 2, Under 4.2 Factor 2 - Key Personnel, can the Design Quality Control Manager be one of the Designers of Record or does this need to be an entirely separate position?

Yes, separate positions are not required. Please bid as shown.

General Requirements / Quality Control 001200 / 01 45 04

Section 001200, Page 5, 4.4 Factor 4 - Design Quality Control requests that we "Provide copies of checklists, as required by the contract in Section 01 45 04…" Are these checklists to be included in the 75 page limit count for the Technical Volume?

Our sample checklists will put us over the page limit. See Amendment No. 0003.

84 Civil CL101 and A101

The floor plan drawing shows the screening wall being 22’ from the face of the proposed building while the site layout plan shows the wall as 27’ from the building. In either location the wall will be partially on top of an existing sanitary sewer lateral. What is the purpose and the criteria for the location of this wall? See Amendment No. 0003.

Section 00120 Page 1

SECTION 00120

PROPOSAL SUBMISSION REQUIREMENTS, EVALUATION CRITERIA AND BASIS OF AWARD

ONE STEP-LOWEST-PRICE TECHNICALLY ACCEPTABLE (LPTA)

1.0 OVERVIEW: The Government will evaluate proposals in accordance with the evaluation criteria and the evaluation rating described herein. Price information will be evaluated for fairness, reasonableness, and for material unbalancing, also as described herein.

2.0 BASIS OF AWARD: In accordance with FAR 15.101-2, award will be made on the basis of the lowest evaluated price of proposals satisfying the requirements of the technical evaluation factors set forth in the solicitation.

3.0 GENERAL INSTRUCTIONS

3.1 The solicitation is to inform all potential offerors that the Government intends to make a contract award without discussions except when the Government determines that it is in its best interest to hold discussions. Proposals should be submitted initially on the most favorable terms from a price and technical standpoint. Do not assume that Offerors will be contacted or afforded an opportunity to clarify, discuss or revise their proposals.

3.2 Firms formally organized as construction contractors that have associated specifically for this project, consortia of firms or any other interested parties may submit proposals. Associations may be as joint ventures or as key term subcontractors. Any legally organized Offeror may submit a proposal, provided that the Offeror or Offeror’s subcontractor has or will have professional architects and engineers listed as key personnel in accordance with Section 01 45 04, CONTRACTOR QUALITY CONTROL, registered in the appropriate technical field as indicated.

3.3 Submit hard copy of proposals in two volumes in tabbed, three-ring binders. Technical and Price proposal shall be submitted under separate cover. Volume 1 shall contain the Technical Items Requested and Volume 2 shall contain the Price Proposal & Other Related Financial Information. Each Volume shall be clearly marked as to its content, i.e., project title, technical or price proposal, solicitation number, name and address of the offeror, and the time specified for receipt. Information within each volume, shall be organized sequentially under the specified tabs to facilitate evaluation. Proposals shall not exceed page limitations prescribed below. Offerors shall also submit electronic copies of Volume 1 Technical Items Requested on compact disc(s) in PDF format. Within three (3) days of contract award, the awardee shall submit ALL volumes in electronic format.

3.4 Page Limits: The following page limits shall apply, which do not include title sheets, indices, tables of content, schedules, or cover sheets: Seventy-five (75) pages maximum for Volume 1 excluding past performance information/evaluation questionnaires or substitute correspondence from references. Checklists are also excluded from this page limit. This page limit includes pages with illustrations/photos/sketches.

Any evaluation documentation beyond 75 pages will not be read or considered during the evaluation process.

A page printed on both sides will be counted as two pages. Pages containing text shall be submitted on 8-1/2 x 11 inch paper. Each page shall be minimally single spaced with a minimum of a 12-point font and one inch margins all around.

4.0 EVALUATION FACTORS: Proposals must meet all of the evaluation factors listed below to be considered acceptable. Proposals which do not meet all of the evaluation factors listed below will be unacceptable and will receive no further consideration.

Section 00120 Page 2

4.1 FACTOR 1 - EXPERIENCE: The Government will review the experience of the offeror. Offerors must meet all of the following requirements to receive an “acceptable” rating for this evaluation factor.

a. Experience with Similar Scope: An offeror shall convincingly demonstrate design and construction experience by providing evidence of at least three (3) projects of at least the scope, dollar value, and complexity described below, and substantially completed (greater than or equal to 75%) within the last five years as of the date of this proposal submission. For this acquisition, a project of similar scope, dollar value, and complexity is defined as a project involving the construction or design of administrative facilities of similar size. Each project must have a construction value of at least $2,000,000 U.S. dollars. For joint venture, teaming agreement, or partnership offerors, this experience shall be satisfied by submitting conforming experience from any or all of the joint venture, partnership, or teaming agreement partners. Offerors shall also provide experience information in the same manner as required for the prime contractor offeror for each subcontractor proposed to perform more than 20 percent of the project design and/or on-site construction work.

Each project submitted for evaluation shall include the following descriptive information: (i) project title, (ii) geographic location, (iii) date that the project was substantially completed, (iv) final project U.S. dollar value, (v) detailed description of the project, and (vi) a description of the actual involvement in the performance of the presented project. Offerors are required to provide information that convincingly demonstrates that the experience presented meets the requirements of qualifying construction and design experience (see requirements above).

b. If an offeror is a joint venture or a partnership or has a teaming agreement composed of two or more partners or proposes subcontractor(s) to perform more than 20 percent of the project on-site construction work, the offeror shall describe the project work that each member of the joint venture, partnership, teaming agreement or the subcontractors would perform. The Government will assess the experience information provided in relation to the work that each of the joint venture or teaming agreement partners or subcontractors would be performing.

4.2 FACTOR 2 - KEY PERSONNEL: An offeror shall provide resume information concerning the qualifications and experience of its intended key personnel as identified below:

a. Designer(s) of Record

b. Design Quality Control Manager

c. On-Site Construction Superintendant/Manager

d. On-Site Safety Officer (Site Safety and Health Officer (SSHO))

e. Contractor Quality Control Manager (Contractor Quality Contract Systems Manager (CQCSM))

The Government will compare this resume information against any and all requirements contained in the RFP in the locations shown below:

a. Designer(s) of Record - Section 00700 - Contract Clauses: 52.236-25 and SECTION 01 33 16

b. On-Site Safety Officer (Site Safety and Health Officer (SSHO)) – SECTION 01 35 26.

c. Design Quality Control Manager and Contractor Quality Control Systems Manager – SECTION

01 45 04.

The qualifications of the On-Site Construction Superintendant/Manager are as follows:

Section 00120 Page 3

a. Minimum of 5 years experience as a construction superintendent with projects of similar scope and complexity.

Failure to satisfy a material requirement for any of the personnel listed above will be a basis for receiving an unacceptable rating.

All resumes shall include the following information to the extent required by the solicitation and are not to exceed three pages in length for each resume. Information presented beyond the three-page limitation for each resume will not be considered in the Government’s evaluation process.

a. Name of person

b. Proposed project assignment

c. Name of firm with which presently associated and or employed

d. Years of experience as it applies to the position that would be filled

e. Educational degree(s), year of graduation and institution

f. Active professional registration (if any), year first registered, if applicable List of projects in which the individual has worked to include name of project(s), project location(s), and work assignments performed

4.3. FACTOR 3 - PAST PERFORMANCE: Past performance pertains to how well an offeror has performed relevant past work that is an indicator of future performance. Past performance information is not the same as experience information. Experience information pertains to what types of work an offeror has performed.

Past performance pertains to how well an offeror performs project work. For the purpose of this evaluation, past performance means an offeror’s reputation for satisfying its customers by delivering:

a. quality work

b. in a timely manner

c. at a reasonable cost

d. in a safe working environment as well as its reputation for

e. reasonable and cooperative conduct

f. overall commitment to customer satisfaction

Offerors are reminded that while the Government may elect to consider past performance information obtained from other sources, the primary responsibility for providing past performance information rests with the offeror. In the case of an offeror that does not have a record of relevant past performance, or for whom information on past performance is not available, the offeror may not be evaluated favorably or unfavorably as concerns its past performance. In situations of this kind, the adjective rating of neutral will be applied to the evaluation factor of Past Performance, to include the evaluation of Construction Contractor(s) and Subcontractor(s) Past Performance and Designer(s) Past Performance. There are two categories of Past Performance with this evaluation factor.

a. Construction Contractor(s) and Subcontractor(s) Past Performance:

(1) The Government will evaluate an offeror’s reputation for performing work in a manner commensurate with the six areas of interest listed above.

(2) This evaluation element is applicable to Construction contractors and subcontractors, where the total subcontracting efforts performed on site (involving management and/or construction efforts) equates to twenty percent or more of the on-site project work effort. An offeror should provide written evidence of the above described six past performance qualities (see items (a) through (f)) in the form of, but not limited to:

1. letters and certificates of commendation

Section 00120 Page 4

2. performance awards

3. performance evaluations

4. evidence of repeat work with the same clients or owners (particularly when noncompetitively obtained), etc.

(3) Offerors are encouraged to solicit and obtain letters of recommendation from past owners, customers and clients from which written documentation contemporaneous with project performance may not be available. These past performance documents should not reference work completed more than six years prior to the date of proposal submission for this solicitation. Past performance documents older than six years will not be considered in the evaluation and selection processes.

(4) If an offeror is a joint venture or partnership, information pertaining to the areas identified as

(a) through (f), above should be presented for each member of the joint venture or partnership (unless the information being presented is in regard to the joint venture or partnership as constituted in response to this solicitation). Although the Government prefers all members of a joint venture or partnership to have satisfied all the above indicated six performance areas, the Government will consider the complementary aspects of the separate participants in a joint venture or partnership, by evaluating the joint venture or partnership as a whole.

(5) Past performance information provided for a member of a joint venture or partnership having no involvement in the project will not be considered in the Government’s Past Performance factor evaluation. Past performance information will only be evaluated from firms proposed to be involved in an offeror’s approach for performance of the solicitation work.

(6) In addition to the evidence submitted by an offeror, the Government may consider information from other sources, including but not limited to: past and present customers and their current and former employees; federal, state and local agencies (including court records); private consumer organizations; and Government past performance databases. In gathering this additional past performance information, the Government will attempt to contact an offeror’s past customers and clients for which contact information is provided by the offeror in response to the portion of the factor.

b. Designer(s) Past Performance:

(1) The Government will evaluate a proposed Designer’s reputation for performing work in a manner commensurate with the six areas of interest listed above.

(2) An offeror should provide written evidence for its proposed Designers of the above described six past performance areas of interest (see (a) and (f above) in the form of, but not limited to:

1. letters and certificates of commendation, performance awards, performance evaluations

2. evidence of repeat work with the same clients or owners (particularly when noncompetitively obtained), etc.

(3) Offerors are encouraged to solicit and obtain letters of recommendation for its proposed

Designers, from past owners, and/or customers and clients from which contemporaneous written documentation may not be presently available. These past performance documents should not reference work completed more than six years from the date of the solicitation.

Past performance documents that are older than six years will not be considered in the evaluation and selection processes.

(4) In addition to the past performance documentation submitted by an offeror for its proposed

Section 00120 Page 5

Designers, the Government may consider information from other sources, including but not limited to: past and present customers and their current and former employees; federal, state and local agencies (including court records); private consumer organizations; and Government past performance databases. In gathering this additional past performance information, the Government will attempt to contact an offeror’s past customers and clients for which contact information is provided by the offeror in response to the Experience portion of this factor.

4.4 FACTOR 4 – DESIGN QUALITY CONTROL: The Offeror shall provide information on the disciplined processes that will be utilized by the Designer to ensure the design portion of this contract is performed and provided in a manner that meets professional architectural and engineering quality standards.

Provide copies of checklists, as required by the contract in Section 01 45 04 Contractor Quality Control, that will be utilized in the contract, as well as, other procedures utilized in the Design Quality Control process.

The Offeror’s Design Quality Control program will be reviewed to determine if it the Offeror receives an “acceptable” rating for this Factor.

5.0 PRICE EVALUATION: The Government will evaluate proposals for the purpose of determining the reasonableness and completeness of the prices offered. Price proposals will be analyzed for unbalanced pricing as a part of the Government’s reasonableness determination. Completeness includes review of Proposal.

5.1 FACTOR 5 – PRICE (STANDARD FORM 1442 AND CONTRACT LINE ITEM SCHEDULE).

5.1.1 Submission Requirements:

5.1.1.1 Submit the properly filled out and executed SF 1442, along with the Price Proposal Schedule, executed Bid Bond, and Section 00600, "Representations and Certifications”. See instructions in Section 00100, “Bidding Schedule/Instructions to Bidders”. For joint ventures, partnerships, and teaming agreements, submit an executed copy of the joint venture, partnership, or teaming agreement with the price proposal.

5.1.1.1.1 Supplemental Price Breakdown. If deemed necessary to evaluate the price proposals, the

Government will request a price breakdown of the Contract Line items in a sealed envelope marked “Price Breakdown Information,” in Excel format. The Government will provide details on where and how to send the breakdown. This information will not be needed sooner than three working days after the proposal submission due date. This information may be required for the initial proposal and, if requested, for any revised proposals. This information is not an opportunity for an Offeror to revise its non-price or price proposal.

5.1.2 Evaluation Criteria:

5.1.2.1 The contract resulting from this solicitation will be awarded to the responsive and responsible offeror submitting the lowest reasonable price that has an overall acceptable rating concerning non-pricing evaluation factors. Price will be evaluated for fairness and reasonableness through the use of a price analysis. The price evaluators will also check for appearance of unbalanced line item prices.

Offerors are cautioned to distribute direct costs, such as material, labor, equipment, subcontracts, etc.

and to evenly distribute indirect costs, such as job overhead, home office overhead, bond, etc., to the appropriate contract line items. Both parties shall presume that field overhead costs through the proposed contract duration are inclusive in the offered price for the contract.

5.1.2.2 If deemed necessary, the supplemental price breakdown information will be used to assist the

Section 00120 Page 6

Government in performing the price evaluations described above.

5.2 EVIDENCE OF BONDABILITY

5.2.1 Submission Requirements: Submit the Bid Bond in accordance with the Instructions in Section 00700, Provision 52.228-1 Bid Guarantee.

5.2.2 Evaluation requirements: This item is not rated. The Government will review the Bid Bond for legal sufficiency. The Bond must be legally sufficient.

6.0 EVALUATION PROCEDURES

6.1 The offeror that submits the lowest complete and reasonable, technically acceptable price proposal will be selected for the contract award. To be considered technically acceptable, an offeror’s proposal must not be rated “unacceptable” under any technical factors.

6.2 An “acceptable” rating will be assigned to a proposal that has satisfied all of the requirements of the technical evaluation factors set forth in the solicitation. An “unacceptable” rating will be assigned to a proposal that has not satisfied one or more requirements of the technical evaluation factors set forth in the solicitation.

6.3 The Government cannot make the contract award to an offeror that is determined to have a technical proposal that is deficient or unacceptable. An “unacceptable” rating will make the offeror ineligible for the contract award, unless the Government elects to enter into discussions with offerors and all deficiencies are remedied in a revised proposal. It is the intent of the Government to award a contract without discussions, although the Government reserves the right to conduct discussions if it is determined to be in the Government’s best interest. Therefore, an offeror that desires consideration for the contract award is advised to comply with all mandatory requirements of this solicitation for submission of price and non-price proposals.

6.4 In accordance with FAR 15.101-2, award will be made on the basis of the lowest evaluated price of proposals satisfying the requirements of the technical evaluation factors set forth in the solicitation.

Section 00815 Page 1

General Decision Number: DE120004 01/06/2012 DE4

Superseded General Decision Number: DE20100005

State: Delaware

Construction Type: Building

County: Kent County in Delaware.

Modification Number Publication Date 0 01/06/2012

ASBE0042-001 07/18/2011

Rates Fringes

Asbestos Worker/Heat and Frost Insulator..................$ 30.07 20.26

BRDE0001-002 05/01/2011

Rates Fringes

TILE FINISHER....................$ 21.37 14.40

TILE SETTER......................$ 27.69 17.03

BRDE0001-003 05/01/2011

Rates Fringes

BRICKLAYER.......................$ 28.00 17.03

CARP0454-005 07/01/2011

Rates Fringes

PILEDRIVERMAN....................$ 38.15 28.27

Footnote: PAID HOLIDAYS: Washington's Birthday, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, and Christmas Day (provided the employee works the day before the holiday and the day after the holiday).

CARP0626-001 05/01/2011

Rates Fringes

CARPENTER

Including Acoustical Ceiling Install, and Drywall Hanging.............$ 30.07 18.99 Scaffold....................$ 30.82 18.99

CARP1823-006 05/01/2011

Rates Fringes

Section 00815 Page 2

Soft Floor Layers, Carpet and Vinyl............................$ 26.36 18.56

* CARP1906-006 07/01/2011

Rates Fringes

MILLWRIGHT.......................$ 33.47 27.23

ELEC0313-001 06/01/2011

Rates Fringes

ELECTRICIAN......................$ 35.00 23.70

ENGI0542-018 06/01/2010

Rates Fringes

Operating Engineers:

Backhoes, Bulldozers, Cranes, Graders, Loaders, and Scrapers................$ 34.54 21.27 Roller......................$ 32.36 20.62

FOOTNOTE: A. PAID HOLIDAYS: New Year's Day, Memorial Day, Independence Day, Labor Day, Thanksgiving Day, Christmas Day, and Election Day (provided the employee works the scheduled work day following the holiday)

IRON0451-001 07/01/2009

Rates Fringes

IRONWORKER

Ornamental, Reinforcing Rigger and Structural.......$ 31.60 23.90

LABO0199-001 05/01/2009

Rates Fringes

Laborers:

Brick Mason Tender, Cement/Concrete (Incl.

Mason Tending) and Power Tool Operator...............$ 22.80 13.30 Common/Unskilled............$ 22.80 13.30

PAIN0021-017 05/01/2011

Rates Fringes

GLAZIER..........................$ 37.35 25.15

PAIN0021-020 05/01/2011

Section 00815 Page 3

Rates Fringes

Painters:

Brush and Roller............$ 25.21 15.36

PAIN0021-033 05/01/2011

Rates Fringes

Drywall Finisher/Taper...........$ 25.71 15.36

PLAS0008-004 05/01/2011

Rates Fringes

PLASTERER........................$ 33.90 23.55

PLAS0592-033 05/01/2011

Rates Fringes

CEMENT MASON/CONCRETE FINISHER...$ 30.79 13.58

ROOF0030-022 05/01/2009

Rates Fringes

ROOFER, Including Waterproofing....................$ 30.00 22.70

SFDE0669-001 04/01/2011

Rates Fringes

SPRINKLER FITTER.................$ 31.75 18.50

SHEE0019-003 07/01/2009

Rates Fringes

Sheet Metal Worker (HVAC Duct Only)............................$ 32.27 31.47+A

FOOTNOTE A: PAID HOLIDAY: Election Day.

SUDE2007-001 08/16/2007

Rates Fringes

ABATEMENT WORKER: ASBESTOS

(Removal from Floors, Ceilings, and Walls).............$ 18.68 6.89

OPERATOR: Forklift..............$ 31.28 6.70

PAINTER: Spray Only.............$ 21.43 8.08

Section 00815 Page 4

PIPEFITTER, Including HVAC Pipe.............................$ 24.43 15.32

PLUMBER, Excluding HVAC Pipe.....$ 25.90 6.81

SHEETMETAL WORKER, Excluding HVAC Duct Installation...........$ 26.30 17.94

WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental.

Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)).

The body of each wage determination lists the classification and wage rates that have been found to be prevailing for the cited type(s) of construction in the area covered by the wage determination. The classifications are listed in alphabetical order of "identifiers" that indicate whether the particular rate is union or non-union.

Union Identifiers

An identifier enclosed in dotted lines beginning with characters other than "SU" denotes that the union classification and rate have found to be prevailing for that classification. Example: PLUM0198-005 07/01/2011. The first four letters , PLUM, indicate the international union and the four-digit number, 0198, that follows indicates the local union number or district council number where applicable , i.e., Plumbers Local 0198. The next number, 005 in the example, is an internal number used in processing the wage determination. The date, 07/01/2011, following these characters is the effective date of the most current negotiated rate/collective bargaining agreement which would be July 1, 2011 in the above example.

Union prevailing wage rates will be updated to reflect any changes in the collective bargaining agreements governing the rate.

Non-Union Identifiers

Classifications listed under an "SU" identifier were derived from survey data by computing average rates and are not union rates; however, the data used in computing these rates may

Section 00815 Page 5 include both union and non-union data. Example: SULA2004-007 5/13/2010. SU indicates the rates are not union rates, LA indicates the State of Louisiana; 2004 is the year of the survey; and 007 is an internal number used in producing the wage determination. A 1993 or later date, 5/13/2010, indicates the classifications and rates under that identifier were issued as a General Wage Determination on that date.

Survey wage rates will remain in effect and will not change until a new survey is conducted.

WAGE DETERMINATION APPEALS PROCESS

1.) Has there been an initial decision in the matter? This can be:

* an existing published wage determination

* a survey underlying a wage determination

* a Wage and Hour Division letter setting forth a position on a wage determination matter

* a conformance (additional classification and rate) ruling

On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour Regional Office for the area in which the survey was conducted because those Regional Offices have responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.)

and 3.) should be followed.

With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to:

Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator (See 29 CFR Part 1.8 and 29 CFR Part 7). Write to:

Wage and Hour Administrator U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue.

Section 00815 Page 6

3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to:

Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

4.) All decisions by the Administrative Review Board are final.

END OF GENERAL DECISION

Section 01 10 00 Page 1 of 134

SECTION 01 10 00

STATEMENT OF WORK

1.0 Project Objectives

2.0 Scope

2.1 Site

2.2 Equipment

2.3 Furniture Requirements

3.0 Functional and Area Requirements

3.1 Assumptions

3.2 Mission

3.3 Personnel Requirements

3.4 Space Requirements

3.5 Space Concepts

3.6 Space Requirements

4.0 Applicable Criteria

4.1 Applicable Industry Criteria

4.2 Applicable Military Criteria

4.3 Applicable Dover Air Force Base Specific Criteria

4.4 Other Applicable Government Material

4.5 Precedence

5.0 General Technical Requirements

5.1 Site Planning and Design

5.2 Site Engineering

5.3 Architecture and Interior Design

5.4 Structural Design

5.5 Thermal Performance

5.6 Plumbing

5.7 Electrical Systems

5.8 Heating Ventilating and Air Conditioning

5.9 Energy Conservation

5.10 Fire Protection and Life Safety

5.11 Sustainable Design

5.12 Security (Anti-Terrorism Standards)

Section 01 10 00 Page 2 of 134

6.0 Project Specific Requirements

6.1 General

6.2 (Not Used)

6.3 Site Planning and Design

6.4 Site Engineering

6.5 Architecture

6.6 Structural Design

6.7 Thermal Performance

6.8 Plumbing

6.9 Site Electrical Systems

6.10 Facility Electrical Systems

6.11 Heating, Ventilation, and Air Conditioning

6.12 Energy Conservation

6.13 Fire Protection

6.14 Sustainable Design

6.15 Environmental

6.16 Furniture Requirements

6.17 Security

6.18 Permits

6.19 Demolition

Section 01 10 00 Page 3 of 134

1.0. PROJECT OBJECTIVES

It is the Air Force's objective that the C-5M Formal Training Unit Facility (FTUF) will have a 25-year useful design life before a possible reuse/repurpose or renovation requirement, to include normal sustainment, restoration and modernization activities, and a 50-year building replacement life. Therefore, the design and construction shall provide an appropriate level of quality to ensure the continued use of the facility over that time period with the application of reasonable preventive maintenance and repairs that would be industry-acceptable. The site infrastructure will have at least a 50-year life expectancy with industry-accepted maintenance and repair cycles.

The Government is required by Public Law 102-486, Executive Order 12902, and Federal Regulations 10 CFR 435 to design and construct facilities in an energy-conserving manner while considering life cycle cost over the life of the facilities.

The project site should be developed for efficiency and to convey a sense of unity or connectivity with the adjacent buildings and with the Base as a whole.

Requirements stated in this contract are minimums. Innovative, creative, and life cycle cost-effective solutions, which meet or exceed these requirements, are encouraged.

2.0. SCOPE

2.1 SITE

There are approximately 0.5 acres available for this project.

2.1.1. Building

Provide a 6,027 gross square-foot maximum building. See Paragraphs 3.0 through 6.19.

2.2. EQUIPMENT*

The following is a partial list of Government - Furnished / Government-Installed (GFGI) items. Final coordination of required equipment shall be confirmed with the User.

Coordinate with Government on GFGI item requirements.

G = Government Responsibility

EQUIPMENT* FURNISH INSTALL

Computers, related hardware G G

Copiers G G

Printers G G

Section 01 10 00 Page 4 of 134

2.3. FURNITURE, FIXTURES AND EQUIPMENT (FF&E) REQUIREMENTS (Base Bid)

2.3.1. Provide furniture, fixtures and equipment (FF&E) design for all spaces. See paragraph 3.6 SPACE REQUIREMENTS for requirements for each space.

Coordinate with the User to review and refine these requirements for furniture systems, movable furniture, equipment, existing items to be reused, storage systems, etc. Early coordination of the FF&E schedule is required so the Facility is complete and usable at turnover. FF&E procurement and installation will be based upon the reviewed and approved FF&E package to be provided. See Paragraph

5.3.5.1. All built-in furniture and millwork requirements are the responsibility of the Offeror and is not considered part of the FF&E.

2.3.2. See Paragraph 5.3.5 for Comprehensive Interior Design (CID) requirements. The tasks described in the CID are included in this contract. The Offeror shall coordinate and schedule FF&E installation BY OTHERS. Under the Base Bid, the Offeror shall coordinate, provide and install electrical power and data and voice cabling, from the wall to junction boxes in the ceiling above approved locations of modular workstations. Also under the Base Bid, the Offeror shall also provide all utilities (electrical, data cabling) to, and, all structural blocking and brackets for, the required

FF&E,

2.3.3. See Paragraph 6.16 for FF&E requirements for the design phase.

2.3.4. As part of the CID preparation, Offerors are required to provide a cost estimate for complete FF&E procurement and installation. Government prices shall be utilized to estimate these items.

2.4 FF&E REQUIREMENTS (Option 1)

2.4.1. The Offeror shall procure and install all FF&E from the approved FF&E design provided with the Base Bid. Included with Option 1 shall be power poles and electrical “whips,” provided with the modular furniture. Option 1 includes the complete and usable installation of all FF&E items. Government pricing will be available to the Offeror to purchase these items.

3.0 FUNCTIONAL AND AREA REQUIREMENTS

This section contains the C-5M Formal Training Unit Facility (FTUF) program information and provides the data necessary to inform the quantitative and qualitative requirements for a new FTUF, as well as provides performance criteria for the elements required.

3.1. ASSUMPTIONS

Personnel requirements outlined in this document are based on reporting by the FTUF organization. Final personnel requirements shall be confirmed by the Design- Build (D-B) Offeror with the FTUF organization.

Section 01 10 00 Page 5 of 134

3.2 MISSION

Congress has approved the modification of C-5 aircraft to C-5Ms. The C-5M FTU shall provide office space for the Instructors who will instruct Airmen in these modifications.

3.3 PERSONNEL REQUIREMENTS

Approximately thirty full-time personnel will be located in the new C-5M FTU facility located at Dover AFB, Delaware. Varying numbers of students will be in the building at various times.

3.4 SPACE REQUIREMENTS

3.4.1 This program is developed into the following space categories:

(1) Instructor Offices:

The FTU facility is the offices of the Air Force and Contractor instructors that will instruct Airmen in the modifications of C-5s to C-5Ms. Two Flights, under the Operations Support Squadron (OSS), will occupy the FTUF: The Formal Training Flight (OSF) conducts initial aircraft training. The Aircrew Training Flight (OST) conducts follow-on aircraft training. The instructors are both Military and Contracted. There are 10 Instructors for the OSF and 5 Instructors for the OST. The OSF will occupy one large office space and the OST will occupy another large office space.

(2) OSTM:

The OSTM office is a aviation resources management office that supports the OSS. There are 4 OSTM personnel with two of those personnel directly working with visitors in a “customer service representative” role.

(3) In-Brief Rooms:

The In-Brief Rooms (IBR) shall be for briefings between the Instructors and student(s). They shall be four (4) individual rooms that provide privacy for those briefings. The IBRs shall accommodate one table for four personnel.

(4) Scheduler:

The scheduler’s office shall be located near the main entrance of the facility. This office shall include a service counter and accommodate two personnel.

(5) Private Offices:

(a) The Flight Crew Chief’s and the Deputy Flight Commander offices shall be co-located with the OST/OSTM.

(b) The Lead Flight Engineer (FE) and the Lead Pilot offices shall be co-located with the OSF.

(c) The Chief, Host Aviation Resource Management (CHARM) office shall be co-located with the OSTM.

(d) The Testing Room shall be co-located with the OSF.

Section 01 10 00 Page 6 of 134

(e) The Flight Commanders office shall be located away from foot traffic and noise.

(6) Conference Room:

Like the Scheduler’s office, the conference room shall be located near the main entrance of the facility.

(7) Break Room:

Break Room and rest rooms shall be colocated with the mechanical room, as best as possible, to minimize piping lengths.

3.4.2 Program of Spaces

The chart below summarizes the gross program areas per the From 1391 for the C-

5M FTUF.

Space Program Quantity Total Net Size SF

Remarks

Flight Commander 1 147

Lead Pilot Instructor 1 150

Lead Flight Engineer Instructor 1 160

Testing Room 1 117

OSF 1 1301

Flight Crew Chief Office 1 123

Deputy Flight Commander 1 134

OST/OSTM 1 917

CHARM Office 1 108

In-Brief Rooms (IBR) 4 559

Scheduler 1 244

Conference Room 1 312 For minimum 10 Crewmembers

Break Room 1 151

Section 01 10 00 Page 7 of 134

Supply Room 1 106

Mechanical/Electrical/Communications Space 1 533

Restrooms 2 322

Janitor’s Closet 1 28

Corridor 1 612

Approximate Total Program Square Feet 6,024

6,027 Building Gross SF

The square footage for these programmed spaces are a guide and can be adjusted. However, the Comm/Data Room shall be a minimum of 77 square feet.

The RFP drawings include a proposed floor layout that has been reviewed and accepted by the Users. The Offeror shall be responsible for ensuring that the final approved floor layout meets Building Code, UFC, and User requirements.

3.5 SPACE CONCEPTS

3.5.1 Overall Building Adjacencies: The following diagram describes the optimal adjacency of areas and support spaces composing the new FTUF. These adjacencies shall be further developed during design when specific floor plan layouts can be tested for fit.

The Design-Build (D-B) Offeror shall be responsible for developing the final floor plan with the User. Refer to D-B RFP Drawings included as an attachment.

Section 01 10 00 Page 8 of 134

SPACE ADJACENCY DIAGRAM

3.6 SPACE REQUIREMENTS:

Unless noted, spaces within the new Facility shall be designed, furnished and constructed using standards as specified herein. These space requirements should be considered in conjunction with the above Bubble diagram. Refer to D-B RFP Drawings, included as an attachment.

3.6.1 Private Offices: Lead Pilot, Lead Flight Engineer, Testing Room, Flight Crew Chief, Deputy Flight Commander, CHARM.

General Description:

These are private office spaces.

Occupancy Requirements:

There is one person who will occupy each of these private offices.

Build-out Requirements:

Floor Material:

Section 01 10 00 Page 9 of 134

Carpet Tile 24”x24”–Type 6 Nylon, solution dyed, 5/64 gauge min., 24 oz. min.

Base Material:

4” Rubber Base.

Window Treatment:

1/2”…