080310-3 ENGINE MONITORING SYSTEM CABLING REQUIREMENTS.pdf

PDF 73 KB Posted

Attached to
AWARD OF DRY DOCKING & REPAIR FOR THE DREDGE MCFARLAND
Solicitation number
W912BU-10-R-0033
Issued by

About this file

MACH-301 080310-3 ENGINE MONITORING SYSTEM CABLING REQUIREMENTS.pdf

View the file

Other files

File Type Posted
ETMS 215-276.xls XLS spreadsheet
ETMS 277-282.xls XLS spreadsheet
ETMS 084-133.xls XLS spreadsheet
W912BU-10-R-0033 0013 LINE ITEMS SPECS SECT H EXTEND RESPONSE DATE.pdf PDF
ETMS 035-083.xls XLS spreadsheet
W912BU-10-R-0033 PRICING WORKBOOK 24NOV10.xls XLS spreadsheet
ETMS 134-199.xls XLS spreadsheet
ETMS COVER-LETTER.xls XLS spreadsheet
ETMS 001-034.xls XLS spreadsheet
ETMS ASBESTOS REPORTS.xls XLS spreadsheet
MF-H5-057-3 22NOV.TIF TIF image
FIBER OPTICS TEST PROCEDURE 22NOV.pdf PDF
MF-H5-051 22NOV.TIF TIF image
MF-H5-57 22NOV.tif TIF image
Mf-h5-51 22NOV.tif TIF image
MF-H5-116 22NOV.TIF TIF image
MF-H5-049-R3 22NOV .TIF TIF image
MF-H2-032 22NOV.TIF TIF image
MASTER CABLE LIST REV_B 22NOV.pdf PDF
MF-H5-115 22NOV.TIF TIF image
MF-H5-057 22NOV.TIF TIF image
MF-H5-080 22NOV.TIF TIF image
MF-H5-050 22NOV.TIF TIF image
MF-H3-024 Pilot House 22NOV.pdf PDF
MF-H5-057-1 22NOV.TIF TIF image
MF-H4-25 22NOV.tif TIF image
MF-H5-058 22NOV.TIF TIF image
333-F518-01 -- JETTING SYSTEM MODIFICATIONS REV_A.pdf PDF
MF-M1-8-1 22NOV —
MF-M1-8-2 22NOV —
MF-H2-114 22NOV.TIF TIF image
MF-H5-053 22NOV.TIF TIF image
MF-H5-049-R2 22NOV.TIF TIF image
MF-H5-059 22NOV.TIF TIF image
MF-M1-8-3 22NOV —
LIGHTING PANEL LOCATIONS.pdf PDF
MF-H5-057-2 22NOV.TIF TIF image
9-7-281 -- JETTING WATER AND HOPPER WASHDOWN SYSTEM PLANS SECTIONS AND ELEVATIONS REV_A 22NOV.pdf PDF
MF-H4-012-2 22NOV —
MF-H5-049-R1 22NOV.TIF TIF image
WB912BU-10-R-0033 AMENDMENT 0012.pdf PDF
10-R-0033-0011.pdf PDF
W912BU-10-R-0033 0010 CHANGE POP EXTEND RESPONSE DATE.pdf PDF
W912BU-10-R-0033 0009 EXTEND RESPONSE DATE.pdf PDF
W912BU-10-R-0033 0008 ADDTNL VESSEL VISIT.pdf PDF
W912BU-10-R-0033 0007 MCH301D EXTND DATE.pdf PDF
MF-M3-60 -- ARRANGEMENT OF CENTRAL CONTROL STATION.TIF TIF image
MF-M3-61 -- CABLING AND CONNECTION DIAGRAM CENTRAL ENG CONTROL STAION PANELS AND CONSOLES.TIF TIF image
080310-2 REVD ENGINE MONITORING SYSTEM.PDF PDF
9-7-2514 -- Engine Starting Monitoring Console.pdf PDF
Show 40 more

Latest 50 of 183 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Acronym Definition AMS Alarm and Monitoring System PDE Port Dredge EnginePDE Port Dredge Engine SDE Starboard Dredge Engine CDE Center Dredge Engine PAE Port Aux Engine SAE S b d A E iSAE Starboard Aux Engine CAE Center Aux Engine HMI Human Machine Interface LOP Lube Oil Pressure LOT Lube Oil Temperature RW1 Raw Water Pressure (before strainer) RW2 Raw Water Pressure (after strainer) FOP Fuel Oil PressureFOP Fuel Oil Pressure JWTI Jacket Water Temp In JWTO Jacket Water Temp Out DI Digital Inputs

CABLE ID CABLE MANUFACTURER PART NUMBER DESCRIPTION FROM TO ESTIMATED LENGTH REQUIRED SENSOR/TRANSDUCER MOUNTING

AMS‐PROFI‐1 BELDEN 3076F Profibus Engine Room Remote I/O Panel Generator Room Remote I/O Panel 20' N/A

AMS‐PROFI‐2 BELDEN 3076F Profibus Engine Room Remote I/O Panel Central Control Station (CCS) 75' N/A AMS‐PROFI‐3 CAT‐5 CCS Dredge Pump Control Panels 50' N/A AMS‐HMI‐7 CAT‐5 Dredge Pump Control Panels Aux Switchgear 25' N/A

AMS‐PDE‐LOP MONROE LS2SJ‐16 Twisted Shielded Pair FWD Engine Room Bulkhead Engine Room Remote I/O Panel 30' Mount DANFOSS MBC5000 series pressure transducer at existing pressure switch location on FWD engine room bulkhead. Provide tubing.

AMS‐PDE‐LOT MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

AMS‐PDE‐RW1 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

Mount DANFOSS MBC5000 series pressure transducer at existing local

AMS‐PDE‐RW2 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

AMS‐PDE‐JWTI MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

AMS‐PDE‐JWTO MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

Mount DANFOSS MBC5000 series pressure transducer adjacent to local engine panel. Provide tubing to "T" into fuel oil pressure feed to local

AMS‐PDE‐FOP MONROE LS2SJ‐16 Twisted Shielded Pair Adjacent to Local Engine Panel Engine Room Remote I/O Panel 30' engine panel. Provide tubing to T into fuel oil pressure feed to local engine panel.

AMS‐PDE‐RPM MONROE LS2SJ‐16 Twisted Shielded Pair Tach gen on engine Engine Room Remote I/O Panel 50' N/A. Existing tach generator.

AMS‐PDE‐DI GENERAL CBL 356760 8 Conductor 14 AWG Local Engine Panel Engine Room Remote I/O Panel 50' N/A

AMS‐SDE‐LOP MONROE LS2SJ‐16 Twisted Shielded Pair FWD Engine Room Bulkhead Engine Room Remote I/O Panel 30' Mount DANFOSS MBC5000 series pressure transducer at existing pressure switch location on FWD engine room bulkhead. Provide tubing.

AMS‐SDE‐LOT MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

AMS‐SDE‐RW1 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

Mount DANFOSS MBC5000 series pressure transducer at existing local

AMS‐SDE‐RW2 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

AMS‐SDE‐JWTI MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

AMS‐SDE‐JWTO MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

Mount DANFOSS MBC5000 series pressure transducer adjacent to local engine panel. Provide tubing to "T" into fuel oil pressure feed to local

AMS‐SDE‐FOP MONROE LS2SJ‐16 Twisted Shielded Pair Adjacent to Local Engine Panel Engine Room Remote I/O Panel 30' engine panel. Provide tubing to T into fuel oil pressure feed to local engine panel.

AMS‐SDE‐RPM MONROE LS2SJ‐16 Twisted Shielded Pair Tach gen on engine Engine Room Remote I/O Panel 50' N/A. Existing tach generator.

AMS‐SDE‐DI GENERAL CBL 356760 8 Conductor 14 AWG Local Engine Panel Engine Room Remote I/O Panel 50' N/A

AMS‐CDE‐LOP MONROE LS2SJ‐16 Twisted Shielded Pair FWD Engine Room Bulkhead Engine Room Remote I/O Panel 20' Mount DANFOSS MBC5000 series pressure transducer at existing pressure switch location on FWD engine room bulkhead. Provide tubing.

AMS‐CDE‐LOT MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20' Install new PT1000 RTD in existing thermowell.

AMS‐CDE‐RW1 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 20' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

Mount DANFOSS MBC5000 series pressure transducer at existing local

AMS‐CDE‐RW2 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 20' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

AMS‐CDE‐JWTI MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20' Install new PT1000 RTD in existing thermowell.

AMS‐CDE‐JWTO MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20' Install new PT1000 RTD in existing thermowellAMS‐CDE‐JWTO MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20 Install new PT1000 RTD in existing thermowell.

AMS‐CDE‐FOP MONROE LS2SJ‐16 Twisted Shielded Pair Adjacent to Local Engine Panel Engine Room Remote I/O Panel 20'

Mount DANFOSS MBC5000 series pressure transducer adjacent to local engine panel. Provide tubing to "T" into fuel oil pressure feed to local engine panel.

AMS CDE RPM MONROE LS2SJ 16 T i d Shi ld d P i T h i E i R R I/O P l 20' N/A E i i hAMS‐CDE‐RPM MONROE LS2SJ‐16 Twisted Shielded Pair Tach gen on engine Engine Room Remote I/O Panel 20' N/A. Existing tach generator.

AMS‐CDE‐DI GENERAL CBL 356760 8 Conductor 14 AWG Local Engine Panel Engine Room Remote I/O Panel 20' N/A

Mount DANFOSS MBC5000 series pressure transducer at existing pressure AMS‐PAE‐LOP MONROE LS2SJ‐16 Twisted Shielded Pair FWD Engine Room Bulkhead Engine Room Remote I/O Panel 30' p g p switch location on FWD engine room bulkhead. Provide tubing.

AMS‐PAE‐LOT MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

Mount DANFOSS MBC5000 series pressure transducer at existing local

AMS‐PAE‐RW1 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

AMS‐PAE‐RW2 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

AMS‐PAE‐JWTI MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

AMS‐PAE‐JWTO MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.AMS PAE JWTO MONROE LS3SJ 18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30 Install new PT1000 RTD in existing thermowell.

AMS‐PAE‐FOP MONROE LS2SJ‐16 Twisted Shielded Pair Adjacent to Local Engine Panel Engine Room Remote I/O Panel 30'

Mount DANFOSS MBC5000 series pressure transducer adjacent to local engine panel. Provide tubing to "T" into fuel oil pressure feed to local engine panel.

AMS PAE RPM MONROE LS2SJ 16 T i t d Shi ld d P i T h i E i R R t I/O P l 50' N/A E i ti t h tAMS‐PAE‐RPM MONROE LS2SJ‐16 Twisted Shielded Pair Tach gen on engine Engine Room Remote I/O Panel 50' N/A. Existing tach generator.

AMS‐PAE‐DI GENERAL CBL 356760 8 Conductor 14 AWG Local Engine Panel Engine Room Remote I/O Panel 50' N/A

Mount DANFOSS MBC5000 series pressure transducer at existing pressure AMS‐SAE‐LOP MONROE LS2SJ‐16 Twisted Shielded Pair FWD Engine Room Bulkhead Engine Room Remote I/O Panel 30' p g p switch location on FWD engine room bulkhead. Provide tubing.

AMS‐SAE‐LOT MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

Mount DANFOSS MBC5000 series pressure transducer at existing local

AMS‐SAE‐RW1 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

AMS‐SAE‐RW2 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 45' Mount DANFOSS MBC5000 series pressure transducer at existing local gauges port side engine room. Provide tubing.

AMS‐SAE‐JWTI MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.

AMS‐SAE‐JWTO MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30' Install new PT1000 RTD in existing thermowell.AMS SAE JWTO MONROE LS3SJ 18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 30 Install new PT1000 RTD in existing thermowell.

AMS‐SAE‐FOP MONROE LS2SJ‐16 Twisted Shielded Pair Adjacent to Local Engine Panel Engine Room Remote I/O Panel 30'

Mount DANFOSS MBC5000 series pressure transducer adjacent to local engine panel. Provide tubing to "T" into fuel oil pressure feed to local engine panel.

AMS SAE RPM MONROE LS2SJ 16 Twisted Shielded Pair Tach gen on engine Engine Room Remote I/O Panel 50' N/A Existing tach generatorAMS‐SAE‐RPM MONROE LS2SJ‐16 Twisted Shielded Pair Tach gen on engine Engine Room Remote I/O Panel 50' N/A. Existing tach generator.

AMS‐SAE‐DI GENERAL CBL 356760 8 Conductor 14 AWG Local Engine Panel Engine Room Remote I/O Panel 50' N/A

Mount DANFOSS MBC5000 series pressure transducer at existing pressure AMS‐CAE‐LOP MONROE LS2SJ‐16 Twisted Shielded Pair FWD Engine Room Bulkhead Engine Room Remote I/O Panel 20' switch location on FWD engine room bulkhead. Provide tubing.

AMS‐CAE‐LOT MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20' Install new PT1000 RTD in existing thermowell.

Mount DANFOSS MBC5000 series pressure transducer at existing local

AMS‐CAE‐RW1 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 20' gauges port side engine room. Provide tubing.

AMS‐CAE‐RW2 MONROE LS2SJ‐16 Twisted Shielded Pair Engine Room Port Side Engine Room Remote I/O Panel 20' gauges port side engine room. Provide tubing.

AMS‐CAE‐JWTI MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20' Install new PT1000 RTD in existing thermowellAMS‐CAE‐JWTI MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20 Install new PT1000 RTD in existing thermowell.

AMS‐CAE‐JWTO MONROE LS3SJ‐18 3 Conductor Shielded Existing Thermowell on Engine Engine Room Remote I/O Panel 20' Install new PT1000 RTD in existing thermowell.

Mount DANFOSS MBC5000 series pressure transducer adjacent to local i l P id bi "T" i f l il f d l l AMS‐CAE‐FOP MONROE LS2SJ‐16 Twisted Shielded Pair Adjacent to Local Engine Panel Engine Room Remote I/O Panel 20' engine panel. Provide tubing to "T" into fuel oil pressure feed to local engine panel.

AMS‐CAE‐RPM MONROE LS2SJ‐16 Twisted Shielded Pair Tach gen on engine Engine Room Remote I/O Panel 20' N/A. Existing tach generator.

AMS‐CAE‐DI GENERAL CBL 356760 8 Conductor 14 AWG Local Engine Panel Engine Room Remote I/O Panel 20' N/Ag g / / AMS‐CPU‐PWR GENERAL CBL 279220 3 Conductor 10 AWG CCS Ships Service UPS 50' N/A

AMS‐RER‐PWR GENERAL CBL 279220 3 Conductor 10 AWG Engine Room Remote I/O Panel Dredge System UPS 30' N/A Generator Room Remote I/O

AMS‐RGR‐PWR GENERAL CBL 279220 3 Conductor 10 AWG Generator Room Remote I/O Panel Ships Service UPS 20' N/A