This is a Questions and Answers document (Amendment 0001) addressing contractor inquiries regarding the Cherry Creek Dam Gate Stem Rehabilitation service contract. The document provides clarification on two key points: (1) confirmation that NAICS code 811310 (Commercial and Industrial Machinery and Equipment Repair and Maintenance) is set and will not change, and (2) notification that the Performance Work Statement and Attachment A (M-103) have been updated to reflect the re-chroming scope for the main stem and cylinder rod components requiring rehabilitation.

The underlying solicitation (W9128F26QA016) issued by the U.S. Army Corps of Engineers, Omaha District, seeks rehabilitation services for Service Gate Stems No. 2 (base scope) and No. 5 (option) at Cherry Creek Dam in Aurora, Colorado, with a closure date of 10 April 2026 at 2 PM CDT. This 100% small business set-aside contract encompasses comprehensive hydraulic cylinder rehabilitation including stem scoring repair, re-chroming (per the updated amendment), wiper seal installation, and brake leak correction. The primary contact for questions is the Contract Specialist at Tony.J.Manna@usace.army.mil, and the Contracting Office Address is USACE Omaha District, 1616 Capitol Avenue, Omaha, Nebraska 68102-4901.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions and Answers Letter Subject: Cherry Creek Gate Stem Rehab We would like to address questions regarding the upcoming service contract. Please find the answers to your queries below:

1.) The solicitation states the NAICS code 811310 is anticipated but may change. Will the NAICS code change, or is it set?

a. The NAICS code is set and will not change.

2.) Can you verify and confirm the parts of the main stem and/or cylinder rod that need re-chroming?

a. Please see AMD 0001 - We have updated the Performance Work Statement and Attachment A (M-103) to reflect the re-chroming scope.