Am_0004_Dwgs.pdf
PDF 5 MB Posted
- Attached to
- Construct Consolidated MilStar Satellite Communications (SATCOM) Station OFFUTT AFB, NEBRASKA
- Solicitation number
- W9128F22R0028
About this file
This solicitation is for the construction of a consolidated MilStar Satellite Communications station at Offutt Air Force Base in Nebraska. The solicitation was issued by the Department of the Army Corps of Engineers Omaha District. Key requirements include constructing a new SATCOM-MilStar facility to house electronic security system infrastructure, MilStar antenna systems, and associated support spaces. The facility will consolidate multiple existing SATCOM terminals into a single secure complex. Offerors must submit proposals by the date specified in the solicitation to be considered for award. The selected contractor will be responsible for all aspects of design and construction in accordance with military standards and specifications.
View the file
Other files
Show all 23
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X
E x
X
X
X
X
X
X
X
X
BUTLER
BOULEVARD
C
O
M
S A
T
D
R
I V
E
C
O
M
S
A
T
D
R
I V
E
W
A
R
H
A
W
K
W
A
Y
BUILDING
SHED
BUILDING
BUILDING
BUILDING
BUILDING
BUILDING
C O
M
S A
T
D
R I V
E
AREA 1
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
AREA 2
SCALE
SITE PLAN - OVERALL
A1
1" = 60'
BUILDING
ACCESSIBLE PARKING STALL
STRIPING
CONCRETE SIDEWALK
FENCEX
CONCRETE PAVEMENT
33' UNOBSTRUCTED SPACE
PATIO, RE: ARCHITECTURAL AND
STRUCTURAL PLANS
GENERAL SHEET NOTES
1. ALL RADII ARE 3' UNLESS OTHERWISE NOTED
2. ALL ACCESSIBLE PARKING SPACES ARE CAR AND VAN
ACCESSIBLE
3. ALL CURBS ARE 6" UNLESS OTHERWISE NOTED
4. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION
REQUIREMENTS FOR ALL ANTENNAS.
LEGEND
M30 RATED FENCE
12" VERTICAL CURB
6" CURB & GUTTER
US Army Corps of Engineers ®
SHEET ID
U S
A
R M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I L
N
M
E
I S
S U
E
D
A T
E
C O
N T
R A
C T
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
O F
F U
I
R
B
S
E
N
E B
R A
S K
A
S A
T C
M
I L S
T A
R
F
A C
I L I T
Y
P R
O J E
S
G B
P
O M
A H
A
D
I S
T R
I C
T
C
A P
I T
A L
A
V E
S
T E
O M
A H
A
N
E
N
O R
H
O
A D
W A
Y
S T
L O
U I S
M
I S
S O
U R
I
D E
S C
R I P
T I O
N D
A T
E
W F
F
W F
D
M A
R K
SCALES:
S I T
E
P
L A
N
O
V E
R A
L L
CS100
READY TO ADVERTISE
J
G
O O
D W
I N
J
G
O O
D W
I N
J
E
M E
R S
O N
K
D
I C
K E
N S
O
C T
O B
TRUE NORTH
60' 120'0
SCALE: 1"=60'
30'
D
A M
E N
D M
E N
T
EARLY BENEFICIAL OCCUPANCY
ANTENNAE AREA - SEE
SECTION 01 32 52.02 24.
COORDINATE WITH ALL OTHER
DISCIPLINES, INCLUDING UTILITY
COMPANIES TO ENSURE ALL WORK
IS COMPLETED.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
C
O
M
S
A
T
D
R
I V
E
W
A
R
H
A
W
K
C O
M
S A
T
D
R I V
E
R
R
R
R10'
R
R
R
N:492404.73
E:2764838.64
N:492514.37
E:2765189.25
N:492340.48
E:2764812.32
N:492624.87
E:2764989.17 N:492590.87
E:2765099.75
N:492564.64
E:2765101.48
N:492564.64
E:2765129.71
N:492537.77
E:2765188.01
END M30 RATED FENCE
N:492505.48
E:2765287.35
BEGIN M30 RATED FENCE
N:492508.55
E:2765000.40
N:492518.75
E:2765113.12
N:492485.43
E:2765091.41
R
AREA 2
AREA 1
A R
AREA 2
AREA 1
A R
R
AREA 1
A R
AREA 1
R
R
R
R
R
R
R
R
R
R
N:492508.72
E:2765192.91
R
END 6" CURB
N:492364.27
E:2764949.41
END 6" CURB
N:492338.13
E:2764941.04
END OF CURB
N:492508.25
E:2765060.46
END OF CURB
N:492502.31
E:2765083.87
N:492547.41
E:2765300.03
N:492551.72
E:2765286.18
R
SCALE
PARTIAL SITE PLAN - AREA 1
A1
1" = 30'
KEYNOTES
BUILDING
ACCESSIBLE PARKING STALL
STRIPING
CONCRETE SIDEWALK
FENCEX
CONCRETE PAVEMENT, RE: CS501
& CT101-102
33' SETBACK
VESTIBULE, RE: A1/A-121 & A1/S-101
GENERAL SHEET NOTES
1. ALL RADII ARE 3' UNLESS OTHERWISE NOTED
2. ALL ACCESSIBLE PARKING SPACES ARE CAR AND VAN
ACCESSIBLE
3. ALL CURBS ARE 6" UNLESS OTHERWISE NOTED
4. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION
REQUIREMENTS FOR ALL ANTENNAS.
5. THE DEADMEN SHOWN IN PLAN VIEW ARE APPROXIMATE
LOCATIONS. THE DEADMEN MUST BE LOCATED PER SHEETS
CS505 AND CS506
LEGEND
1. SATCOM BUILDING
2. HF ANTENNA
3. UNDERGROUND FUEL TANKS, RE: PLUMBING PLANS
4. FUEL TRUCK STATION CONNECTION, RE: PLUMBING PLANS
5. 33' UNOBSTRUCTED SPACE
6. PEDESTRIAN GATE/TURNSTILE GATE, RE: C1/CS504
7. DOUBLE SWING GATE, RE: A3/CS507
8. PARKING STALL STRIPING, RE: C2/CS502
9. PEDESTRIAN CROSSWALK, RE: A2/CS502
10. ACCESSIBLE RAMP, RE: C4/CS502
11. ABA LOGO, RE: C1/CS502
12. 12" VERTICAL CURB, RE: B4/CS501
13. BARRIER ARM GATE, RE: CS512 & CS513
14. BOLLARDS, RE: B4/CS504
15. DUMPSTER ENCLOSURE, RE: A-551
16. UNDERGROUND WATER TANK, RE: PLUMBING PLANS
17. M30 RATED, REINFORCED DOUBLE SWING GATE, RE:
C2/CS507
18. CURB TRANSITION FROM 12" TO 6"
19. ELECTRICAL EQUIPMENT, RE: ELECTRIC PLANS
20. COMMUNICATION EQUIPMENT, RE: COMMUNICATION PLANS
21. MOW STRIP, RE: D4/CS509
22. DEADMAN, RE: A1/CS505 & A1/CS506
23. 6" CURB, RE: C1/CS501
24. 12" VERTICAL CURB, RE: B4/CS501
31. DRAINAGE CHANNEL, RE: CG100-102
32. CURB TRANSITION FROM 6" TO 0"
33. EQUIPMENT SCREEN, RE: A2/A-551
34. PAVERS, RE: LANDSCAPE PLANS
M30 RATED FENCE
12" VERTICAL CURB
6" CURB & GUTTER
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I
M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
O F
F U
R
S
E
N
E B
R A
S K
A
S A
T C
I L S
T A
R
F
A C
I L I T
Y
P R
O J E
S
G B
P
O M
A H
A
D
I S
T R
I C
T
C
A P
I T
A L
A
V E
S
T E
O M
A H
A
N
E
N
O R
O
A D
W A
Y
S T
L O
U I S
M
I S
S O
U R
I
D E
S C
R I P
T I O
N D
A T
E
W F
F
W F
D
M A
R K
P A
R T
I A
L
S
I T
E
P
L A
N
A
R E
A
CS101
READY TO ADVERTISE
J
G
O O
D W
I N
J
G
O O
D W
I N
J
E
M E
R S
O N
K
D
I C
K E
N S
O
C T
O B
TRUE NORTH
30' 60'0
SCALE: 1"=30'
15'
D
A M
E N
D M
E N
T
X
X
X
X
X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
BUTLER
BOULEVARD
C
O
M
S A
T
D
R
I V
E
W
A
R
H
A
W
K
W
A
Y
R
R
R
R
R137'
R 113'
24'
24'
140.8'
56.8'
R
R
R
R
N:492292.85
E:2764799.46
N:492248.56
E:2764729.11
N:492204.88
E:2764938.20
54.9'
N:492209.72
E:2764777.53
N:492208.16
E:2764783.33
N:492151.13
E:2764761.71
N:492149.14
E:2764767.39
R
N:492149.23
E:2765195.94
N:492173.23
E:2765195.74
N:492267.02
E:2765220.83
N:492290.28
E:2765226.74
N:492218.79
E:2765227.06
N:492218.77
E:2765081.06
N:492248.69
E:2764827.27
N:492307.45
E:2764928.91
AREA 2
AREA 1
A R
R
AREA 2
AREA 1
A R
AREA 2 AREA 2
A R
N:492118.36
E:2765090.60
N:492118.64
E:2765125.10
N:492118.93
E:2765159.59
N:492090.10
E:2765119.33
N:492090.38
E:2765153.83
N:492090.67
E:2765188.33
R
R
53.4'
R
62.5'
SCALE
PARTIAL SITE PLAN - AREA 2
A1
1" = 30'
KEYNOTES
CONCRETE SIDEWALK
FENCEX
33' SETBACK
GENERAL SHEET NOTES
1. ALL RADII ARE 3' UNLESS OTHERWISE NOTED
2. ALL ACCESSIBLE PARKING SPACES ARE CAR AND VAN
ACCESSIBLE
3. ALL CURBS ARE 6" UNLESS OTHERWISE NOTED
LEGEND
M30 RATED FENCE
12" VERTICAL CURB
6" CURB & GUTTER
CONCRETE PAVEMENT, RE: CS501
& CT101-102
5. 33' UNOBSTRUCTED SPACE
9. PEDESTRIAN CROSSWALK, RE: A2/CS502
13. BARRIER ARM GATE, RE: CS512 & CS513
21. MOW STRIP, RE: D4/CS509
23. 6" CURB, RE: C1/CS501
25. RT PAD, RE: A4/CS501
26. MET RADOMES, RE: STRUCTURAL PLANS FOR FOUNDATION
27. FAB-T TOWERS, RE: STRUCTURAL PLANS FOR FOUNDATION
28. STAIRS, RE: CS403
29. SEGMENTAL BLOCK WALL TO MATCH EXISTING.
30. IFL TRENCH, RE: STRUCTUAL
31. DRAINAGE CHANNEL, RE: CG100-102
35. CONDENSER PAD
CONCRETE PAVEMENT, RE: A1/CS501,
CS401 & CS515
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I
M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
O F
F U
R
S
E
N
E B
R A
S K
A
S A
T C
I L S
T A
R
F
A C
I L I T
Y
P R
O J E
S
G B
P
O M
A H
A
D
I S
T R
I C
T
C
A P
I T
A L
A
V E
S
T E
O M
A H
A
N
E
N
O R
O
A D
W A
Y
S T
L O
U I S
M
I S
S O
U R
I
D E
S C
R I P
T I O
N D
A T
E
W F
F
W F
D
M A
R K
P A
R T
I A
L
S
I T
E
P
L A
N
A
R E
A
CS102
READY TO ADVERTISE
J
G
O O
D W
I N
J
G
O O
D W
I N
J
E
M E
R S
O N
K
D
I C
K E
N S
O
C T
O B
TRUE NORTH
30' 60'0
SCALE: 1"=30'
15'
SCALES:
D
A M
E N
D M
E N
T
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
E-704
P A
N E
L B
O A
R D
S W
C H
E D
U L E
S A
R E
A A
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
L M
ID
D
L E
T O
N
L M
ID
D
L E
T O
N
K D
IC
K
E N
S
R K
U R
Z A
W A
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
Notes:
Total Est. Design Current: 37 A
RACK 5000 VA 100.00% 5000 VA Total Conn. Current: 39 A
REC 1620 VA 100.00% 1620 VA Total Est. Demand: 13500 VA
HVAC 5200 VA 90.00% 4680 VA Total Conn. Load: 14020 VA
GEN 2200 VA 100.00% 2200 VA
Load Classification Connected Load Design Factor Estimated Demand Panel Totals
Total Load: 6550 VA 4570 VA 2900 VA
29 0 VA -- 1 -- -- SPACE 30
27 0 VA -- 1 -- -- SPACE 28
SPD -- 20 A 3
0 VA -- 1 -- -- SPACE 26
23 SPACE -- -- 1 -- -- 1 -- -- SPACE 24
21 SPACE -- -- 1 -- -- 1 -- -- SPACE 22
19 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 20
17 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 18
15 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 16
13 GEN REC TELECOM 121 REC 20 A 1 720 VA 0 VA 1 20 A -- SPARE 14
11 1250 VA 0 VA 1 20 A -- SPARE 12
RACK TELECOM 121 RACK 20 A 2
1250 VA 540 VA 1 20 A REC GEN REC SECURITY 122 10
7 1250 VA 1800 VA 1 20 A GEN SECURITY RACK SECURITY 122 8
RACK TELECOM 121 RACK 20 A 2
1250 VA 400 VA 1 20 A GEN ACP SECURITY 122 6
3 2600 VA 180 VA 1 20 A REC RACK TELECOM 121 4
CU-1, ACU-1,ACU-2, ACU-3 HVAC 50 A 2
2600 VA 180 VA 1 20 A REC RACK TELECOM 121 2
CKT Circuit Description Demand Factor Trip Poles A B C Poles Trip
Demand Factor Circuit Description CKT
Accessories:
Mounting: SURFACE Wires: 4 MCB Rating 60 A
Supply From: P2C1 Phases: 3 Bus Rating: 100 A
Location: TELECOM 121 Volts: 120/208 Wye Mains Type: MCB A.I.C. Rating: 10,000
R2C2
Notes:
Total Est. Design Current: 40 A
Total Conn. Current: 42 A
REC 10820 VA 96.21% 10410 VA Total Est. Demand: 14581 VA
HVAC 1968 VA 90.00% 1771 VA Total Conn. Load: 15188 VA
GEN 2400 VA 100.00% 2400 VA
Load Classification Connected Load Design Factor Estimated Demand Panel Totals
Total Load: 5320 VA 5364 VA 4504 VA
29 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 30
27 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 28
25 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 26
23 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 24
21 CAMERA CIB OBSERVATION SPACE 150 REC 20 A 1 180 VA 180 VA 1 20 A REC REC ROOF - MEDIA CONVERTER 22
19 FUTURE EXHAUST FAN REC 20 A 1 460 VA 180 VA 1 20 A REC REC ROOF - MEDIA CONVERTER 20
17 FUTURE EXHAUST FAN REC 20 A 1 460 VA 180 VA 1 20 A REC REC ROOF - ANTI-JAM ANTENNA 18
15 REC SECOND CATWALK OBSERVATION 129 REC 20 A 1 1080 VA 60 VA 1 20 A GEN ARM GATE HEATER 16
13 REC SECOND CATWALK OBSERVATION 129 REC 20 A 1 1080 VA 0 VA 1 20 A HVAC SUMP PUMP - BASEMENT 14
11 REC FIRST FLOOR OBSERVATION SPACE 150 REC 20 A 1 1080 VA 720 VA 1 20 A GEN CAMERA INTERFACE BOX EXTERIOR 12
9 REC FIRST FLOOR OBSERVATION SPACE 150 REC 20 A 1 1080 VA 720 VA 1 20 A GEN CAMERA INTERFACE BOX EXTERIOR 10
7 REC FIRST CATWALK OBSERVATION SPACE 108 REC 20 A 1 1080 VA 900 VA 1 20 A GEN CAMERA INTERFACE BOX EXTERIOR 8
5 REC FIRST CATWALK OBSERVATION SPACE 108 REC 20 A 1 1080 VA 984 VA 1 20 A HVAC DH-2 FIRST CATWALK 108 6
3 REC BASEMENT OBSERVATION SPACE 109 REC 20 A 1 1080 VA 984 VA 1 20 A HVAC DH-1 FIRST CATWALK 108 4
1 REC BASEMENT OBSERVATION SPACE 109 REC 20 A 1 1080 VA 540 VA 1 20 A REC REC EXTERIOR SOUTH 2
CKT Circuit Description Demand Factor Trip Poles A B C Poles Trip
Demand Factor Circuit Description CKT
Accessories:
Mounting: SURFACE Wires: 4 MCB Rating 60 A
Supply From: P2C1 Phases: 3 Bus Rating: 100 A
Location: OBSERVATION SPACE 150 Volts: 120/208 Wye Mains Type: MCB A.I.C. Rating: 10,000
R2C3
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
E C
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
E-705
P A
N E
L B
O A
R D
S C
H E
D U
L E
S A
R E
A S
B A
N D
C
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
L M
ID
D
L E
T O
N
L M
ID
D
L E
T O
N
K D
IC
K
E N
S
R K
U R
Z A
W A
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
Notes:
Total Est. Design Current: 13 A
Total Conn. Current: 15 A
Total Est. Demand: 10714 VA
WATER HEATERS 8000 VA 75.00% 6000 VA Total Conn. Load: 12714 VA
LTG 4714 VA 100.00% 4714 VA
Load Classification Connected Load Design Factor Estimated Demand Panel Totals
Total Load: 11617 VA 325 VA 772 VA
29 0 VA -- 1 -- -- SPACE 30
27 0 VA -- 1 -- -- SPACE 28
SPD -- 30 A 3
0 VA -- 1 -- -- SPACE 26
23 SPACE -- -- 1 -- -- 1 -- -- SPACE 24
21 SPACE -- -- 1 -- -- 1 -- -- SPACE 22
19 SPACE -- -- 1 -- -- 1 -- -- SPACE 20
17 SPACE -- -- 1 -- -- 1 -- -- SPACE 18
15 SPACE -- -- 1 -- -- 1 -- -- SPACE 16
13 SPACE -- -- 1 -- 0 VA 1 20 A -- SPARE 14
11 SPACE -- -- 1 -- 0 VA 1 20 A -- SPARE 12
9 EXIST SIGNS ROOMS 135, 131, 139 LTG 20 A 1 13 VA 0 VA 1 20 A -- SPARE 10
7 LTG OPS FLOOR 135 LTG 20 A 1 2105 VA 0 VA 1 20 A -- SPARE 8
5 LTG OPS FLOOR WORKSTATIONS 140 LTG 20 A 1 772 VA 0 VA 1 20 A -- SPARE 6
3 LTG ROOMS 131, 139, 130, 132, 133, 134 LTG 20 A 1 312 VA 0 VA 1 20 A -- SPARE 4
1 LTG ROOMS 143, 142, 141, 144, 145, 147, 146 LTG 20 A 1 1512 VA 8000 VA 1 40 A WATER... IWH - 1 JANITOR 132 2
CKT Circuit Description Demand Factor Trip Poles A B C Poles Trip
Demand Factor Circuit Description CKT
Accessories:
Mounting: Surface Wires: 4 MCB Rating 250 A
Supply From: SP4A1 Phases: 3 Bus Rating: 400 A
Location: ELECTRICAL 146 Volts: 480/277 Wye Mains Type: MCB A.I.C. Rating: 14,000
SL4A1
Notes:
Total Est. Design Current: 38 A
Total Conn. Current: 43 A
WATER HEATERS 1800 VA 75.00% 1350 VA Total Est. Demand: 13622 VA
HVAC - A 10380 VA 90.00% 9342 VA Total Conn. Load: 15436 VA
HVAC 3256 VA 90.00% 2930 VA
Load Classification Connected Load Design Factor Estimated Demand Panel Totals
Total Load: 6068 VA 4596 VA 4772 VA
29 SPACE -- -- 1 -- -- 1 -- -- SPACE 30
27 SPACE -- -- 1 -- -- 1 -- -- SPACE 28
25 SPACE -- -- 1 -- -- 1 -- -- SPACE 26
23 SPACE -- -- 1 -- -- 1 -- -- SPACE 24
21 SPACE -- -- 1 -- -- 1 -- -- SPACE 22
19 SPACE -- -- 1 -- -- 1 -- -- SPACE 20
17 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 18
15 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 16
13 1040 VA 1176 VA 1 20 A HVAC - A FOP-4 GENERATOR 143 14
DUCT HEAT TRACE CHILLER 142 HVAC 20 A 2
1040 VA 1380 VA 12
9 FC-1 GENERATOR 143 HVAC - A 20 A 1 1560 VA 1380 VA
2 20 A HVAC - A FP-1 CHILLER 142
7 B-1 MECHANICAL 141 HVAC - A 20 A 1 396 VA 0 VA 1 20 A -- SPARE 8
5 F-13 MECHANICAL 141 HVAC - A 20 A 1 1656 VA 696 VA 1 20 A HVAC F-15 JANITOR 132 6
3 GMP-1 MECHANICAL 141 HVAC 20 A 1 480 VA 1176 VA 1 20 A HVAC - A F-11 GENERATOR 143 4
1 IWH-8 WATER... 20 A 1 1800 VA 1656 VA 1 20 A HVAC - A HWP-1 MECHANICAL 141 2
CKT Circuit Description Demand Factor Trip Poles A B C Poles Trip
Demand Factor Circuit Description CKT
Accessories:
Mounting: Surface Wires: 4 MCB Rating 150 A
Supply From: T-SM2A1 Phases: 3 Bus Rating: 225 A
Location: MECHANICAL 141 Volts: 120/208 Wye Mains Type: MCB A.I.C. Rating: 10,000
SM2A1
Notes:
Total Est. Design Current: 10 A
WATER HEATERS 3600 VA 75.00% 2700 VA Total Conn. Current: 41 A
HVAC - B 10380 VA 0.01% 1 VA Total Est. Demand: 3463 VA
HVAC 180 VA 90.00% 162 VA Total Conn. Load: 14760 VA
GEN 600 VA 100.00% 600 VA
Load Classification Connected Load Design Factor Estimated Demand Panel Totals
Total Load: 6192 VA 4536 VA 4032 VA
29 SPACE -- -- 1 -- -- 1 -- -- SPACE 30
27 SPACE -- -- 1 -- -- 1 -- -- SPACE 28
25 SPACE -- -- 1 -- -- 1 -- -- SPACE 26
23 SPACE -- -- 1 -- -- 1 -- -- SPACE 24
21 SPACE -- -- 1 -- -- 1 -- -- SPACE 22
19 SPACE -- -- 1 -- -- 1 -- -- SPACE 20
17 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 18
15 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 16
13 SPARE -- 20 A 1 0 VA 1176 VA 1 20 A HVAC - B FOP-5 GENERATOR 143 14
11 1380 VA 600 VA 1 20 A GEN LEAK DETECTION MASTER MODULE RM... 12
FP-2 CHILLER 142 HVAC - B 20 A 2
1380 VA 1800 VA 1 20 A WATER... IWH-11 GENERATOR 143 10
7 SPARE -- 20 A 1 0 VA 1560 VA 1 20 A HVAC - B FC-2 GENERATOR 143 8
5 F-14 MECHANICAL 141 HVAC - B 20 A 1 1656 VA 396 VA 1 20 A HVAC - B B-2 MECHANICAL 141 6
3 GMP-2 MECHANICAL 141 HVAC 20 A 1 180 VA 1176 VA 1 20 A HVAC - B F-12 GENERATOR 143 4
1 IWH-9 WATER... 20 A 1 1800 VA 1656 VA 1 20 A HVAC - B HWP-2 MECHANICAL 141 2
CKT Circuit Description Demand Factor Trip Poles A B C Poles Trip
Demand Factor Circuit Description CKT
Accessories:
Mounting: Surface Wires: 4 MCB Rating 150 A
Supply From: T-SM2B1 Phases: 3 Bus Rating: 225 A
Location: MECHANICAL 141 Volts: 120/208 Wye Mains Type: MCB A.I.C. Rating: 10,000
SM2B1
CIRCUIT 26,28,30: PROVIDE RED LOCK-ON CIRCUIT BREAKER WITH LABEL "FIRE PROTECTION/LIFE SAFETY EQUIPMENT"
Notes:
REC 10980 VA 95.54% 10490 VA
LTG 71 VA 100.00% 71 VA Total Est. Design Current: 49 A
HVAC - B 3820 VA 0.01% 0 VA Total Conn. Current: 63 A
HVAC - A 3820 VA 90.00% 3438 VA Total Est. Demand: 17623 VA
HVAC 3160 VA 90.00% 2844 VA Total Conn. Load: 22631 VA
GEN 780 VA 100.00% 780 VA
Load Classification Connected Load Design Factor Estimated Demand Panel Totals
Total Load: 8818 VA 8207 VA 5607 VA
29 SPACE -- -- 1 -- 2547 VA 30
27 SPACE -- -- 1 -- 4487 VA 28
25 SPACE -- -- 1 -- 4067 VA
3 60 A HVAC; Spare;
GEN; HVAC -
A; HVAC - B
FIRE
23 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 24
21 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 22
19 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 20
17 SPARE -- 20 A 1 0 VA 0 VA 1 20 A -- SPARE 18
15 SPARE -- 20 A 1 0 VA 0 VA 1 20 A GEN EPO POWER CORRIDOR 131 16
13 REC WORKROOM 137 REC 20 A 1 360 VA 431 VA 1 20 A REC; LTG LTG AND CAMERA CIB VESTIBULE 130, 139 14
11 REC CLASSROOM 136 REC 20 A 1 1080 VA 1080 VA 1 20 A REC REC CLASSROOM 136 12
9 REC CLASSROOM 136 REC 20 A 1 1080 VA 1080 VA 1 20 A REC REC ROOMS 132, 134, 137, 133, 138 10
7 REC CLASSROOM 136 REC 20 A 1 1080 VA 720 VA 1 20 A REC REC OPS FLOOR WORKSTATIONS 140 8
5 REC CHILLER 142 REC 20 A 1 720 VA 180 VA 1 20 A REC REC CORRIDOR 131 6
3 REC ROOMS 146, 147 REC 20 A 1 540 VA 1020 VA 1 20 A HVAC; REC REC MECHANICAL 141 4
1 REC ROOMS 143, 144, 145 REC 20 A 1 1440 VA 720 VA 1 20 A REC REC ROOMS 131, 139 2
CKT Circuit Description Demand Factor Trip Poles A B C Poles Trip
Demand Factor Circuit Description CKT
Accessories:
Mounting: Surface Wires: 4 MCB Rating 100 A
Supply From: T-SR2A1 Phases: 3 Bus Rating: 100 A
Location: ELECTRICAL 146 Volts: 120/208 Wye Mains Type: MCB A.I.C. Rating: 10,000
SR2A1
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
EC
TP
CIB
CIB
CIB
J
J
J
J
J
J
J
A
A
B
B
B.4
B.4
C
C
D
D
E
E
C.1
C.1
C.7
C.7
D.5
D.5
2.9
4.1
5.3
VESTIBULE
OPS FLOOR
WORKSTATIONS
VESTIBULE
MECHANICAL
GENERATOR
BATTERIES / UPS
BATTERIES / UPS
SWITCH
OBSERVATION SPACE
S M
B
M A
T C
H L
IN
E
A
E P
M A
T C
H L
IN
E
A
E P
F
IL
T E
R -E
F
IL
T E
R -E
CORRIDOR
GFI, WP
GFI, WP
GFI, WP
E-401
A1
FAB-T-1-NCR
(GFGI)
FAB-T-2-NCR
(GFGI)
FAB-T-3-NCR
(GFGI)
RT-PAD-CR
RT-PAD-NCR
ELECTRICAL
F
IL
T E
R -E
S M
B
S M
A
TV, 4'-7" AFF
R C
R2C3:9 R2C3:9
R2C3:9
R2C3:9
R2C3:9 R2C3:9
R2C3:2
R2C3:2 R2C3: 2
R2C1:1
F
IL
T E
R -E
SWITCH
SR2A1
SR2A1:1
SR2A1:1
SR2A1:1
SR2A1:1
SR2A1:1
SR2A1:1
SR2A1:3
SR2A1:3
SR2A1:3
SR2A1:5
SR2A1:5
SR2A1:4
SR2A1:5
SR2A1:5
SR2A1:4
SR2A1:4
SR2A1:4
SR2A1: 1,3,5
SR2A1:2
SR2A1:2
SR2A1:2
SR2A1:2
SR2A1: 2,4,6
UR2A1:1
UR2A1:3
UR2A1:3
UR2A1:3
UR2A1:5
UR2A1:5
TV, 4'-7" AFF
TV, 4'-7" AFF
TV, 4'-7" AFF
TV, 4'-7" AFF
UR2A1: 7,9,11,13
UR2A1: 1,3,5
SR2A1:8
SR2A1:8
STS-MET-1
STS-FAB-T-1
STS-MET-2
S T
S -R
T -P
A D
S T
S -F
A B
-T -2
S T
S -F
A B
-T -3
S M
A
9191 91
SM2B1:3
SM2A1:3
FIRE: 8,10
SM2A1: 11,13
FAB-T-1-CR
(GFGI)
FAB-T-2-CR
(GFGI)
FAB-T-3-CR
(GFGI)
979797
UR2A1:15
A/V RACK
SR2A1:14
SR2A1:14
R2C3:21
PLAN
NORTH
T R
U E
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES: KEY PLAN:
B
EP122
P A
R T
IA
L P
O W
E R
P L A
N F
IR
S
T F
L O
O R
A R
E A
B
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
L M
ID
D
L E
T O
N
L M
ID
D
L E
T O
N
K D
IC
K
E N
S
R K
U R
Z A
W A
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SCALE: 1/8" = 1'-0"A2
PARTIAL POWER PLAN - FIRST FLOOR AREA B
04 8 16268
SCALE: 1/8"=1'-0"
GENERAL SHEET NOTES
SHEET KEYNOTES
73 POWER CONNECTION FOR CIB. REFER TO SECURITY DRAWINGS FOR EXACT
LOCATION. EQUIPMENT LOCATED WITHIN VESTIBULE IS SURFACE MOUNTED.
FEEDER ENTERING THE VESTIBULE MUST PASS THROUGH A SIGNAL LINE
FILTER PRIOR TO ENTERING THE SPACE. REFER TO X-SERIES FOR ADDITIONAL
INFORMATION. EQUIPMENT IS FED FROM PANELBOARD SR2A1 UNLESS
OTHERWISE NOTED.
74 POWER CONNECTION FOR CIB. REFER TO SECURITY DRAWINGS FOR EXACT
LOCATION.
86 POWER CONNECTION FOR MECHANICAL CONTROLS. MOUNT BOX 6'-0" AFF AND
LABEL "MECH CONTROL POWER".
88 POWER CONNECTION FOR NITROGEN GENERATOR.
91 REFER TO X-SERIES DRAWINGS FOR ADDITIONAL INFORMATION ON FILTERS
AND PENETRATIONS THROUGH HEMP SHIELD.
93 POWER CONNECTION FOR HEAT TRACING SYSTEM. COORDINATE LOCATION
AND QUANTITY OF BOXES BASED ON SELECTED SYSTEM.
97 CONDUITS PENETRATE HEMP SHIELD ABOUT VESTIBULE 139 HEMP CEILING.
REFER TO X-SERIES FOR ADDITIONAL INFORMATION.
98 EXTEND TO SOURCE. REFER TO ONE-LINE FOR ADDITIONAL INFORMATION.
1. REFER TO EP222 FOR EQUIPMENT PLANS.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
EC
SHEET INDEX
of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
E
ER
S
D R
AW
N
B Y:
D
ES
IG
N
E D
B Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
'D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
A C
T N
O
SO
LI
C
IT
AT
IO
N N
O
FI
LE
N U
M
BE
R
1 2 3 4 5
D
C
B
A
G-002b
SH
EE
T
IN
D E
X
VO
LU
M
E
II
O
FF
U
TT
A
IR
F O
R C
E
BA
SE
, N
EB
R
AS
KA
SA
TC
O M
M
IL
ST
A R
F
AC
IL
IT
Y
PR
O
JE
C T
N O
SG
BP
O M
AH
A
D
IS
TR
IC
T
C
A
PI
TA
L
AV
E, S
TE
. 9
O
M
AH
A, N
E
N O
R
TH
B R
O
AD
W
AY
ST
. L
O U
IS
, M
IS
SO
U R
I 6
M . H
E M
M
ER
N . B
O
YE
R
K.
D
IC
KE
N S
R . Y
AW
O
C
TO
B
ER
W
F2
1F
W
F1
9D
READY TO ADVERTISE
Sheet Number Sheet Name
SECURITY
TY001 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE SYMBOLS AND
GENERAL NOTES
TY101 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - SITE
TY120 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST
FLOOR OVERALL
TY121 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST
FLOOR AREA A
TY122 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST
FLOOR AREA B
TY123 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST
FLOOR - AREA C
TY124 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - ROOF
AREA B
TY401 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - ENLARGED
PLANS
TY501 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE DETAILS
TY502 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE DETAILS
TY503 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE DETAILS
TY601 ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE ONE LINE
DIAGRAM
HEMP
X-001 HEMP PENETRATION SCHEDULE - MECHANICAL
X-002 HEMP PENETRATION SCHEDULE - MECHANICAL
X-003 HEMP PENETRATION SCHEDULE - MECHANICAL
X-004 HEMP PENETRATION SCHEDULE - MECHANICAL
X-005 HEMP PENETRATION SCHEDULE - ELECTRIC
X-006 HEMP PENETRATION SCHEDULE - ARCHITECTRURAL AND
STRUCTRUAL
X-140 FLOOR PLAN - HEMP PLATFORM OVERALL
X-150 REFLECTED CEILING PLAN - HEMP BASEMENT OVERALL
X-400 INTERIOR ELEVATIONS - HEMP WALLS
X-401 INTERIOR ELEVATIONS - HEMP WALLS
X-402 ENLARGED PLANS AND INTERIOR ELEVATIONS - HEMP VESTIBULES
X-500 HEMP PENETRATION TYPE DETAILS - WBC MATRIX
X-501 HEMP PENETRATION TYPE DETAILS - WBC SIEVE
X-502 HEMP PENETRATION TYPE DETAILS - INSULATED WBC SIEVE
X-503 HEMP PENETRATION TYPE DETAILS - STAND-ALONE WBC
X-504 HEMP PENETRATION TYPE DETAILS - INSULATED WBC MATRIX
X-505 HEMP PENETRATION TYPE DETAILS - 7-WAY FIBER CONDUITS
X-506 HEMP PENETRATION TYPE DETAILS - 4-WAY FIBER CONDUIT
X-507 HEMP PENETRATION TYPE DETAILS - STEEL COLUMN
X-508 HEMP PENETRATION TYPE DETAILS - GUSSET PLATE
X-509 HEMP PENETRATION TYPE DETAILS - EQUIPMENT ACCESS PANEL
X-510 HEMP PENETRATION TYPE DETAILS - POWER FILTER
X-511 HEMP PENETRATION TYPE DETAILS - STEEL BEAM
X-512 HEMP PENETRATION TYPE DETAILS - SIGNAL FILTER CABINET
X-513 HEMP PENETRATION TYPE DETAILS - HIGH TEMPERATURE
GENERATOR EXHAUST
X-514 HEMP PENETRATION TYPE DETAILS - FIRE SUPPRESSION ALTERNATE
X-516 HEMP PENETRATION TYPE DETAILS - FILTER CABINET CONDUIT
EXTENSION
X-517 HEMP PENETRATION TYPE DETAILS - I/O PANEL
X-518 HEMP PENETRATION TYPE DETAILS - INSULATED STAND-ALONE WBC
X-519 HEMP PENETRATION TYPE DETAILS - 4-CONDUIT PENETRATION
X-521 HEMP PENETRATION TYPE DETAILS - 6-CONDUIT PENETRATION
X-524 HEMP PENETRATION TYPE DETAILS - STAND-ALONE WBC
(ELECTRICAL)
X-525 SIGNAL FILTER PENETRATION CONFIGURATION
Sheet Number Sheet Name
ELECTRICAL
E-001 SYMBOLS
E-002 ABBREVIATIONS AND GENERAL NOTES
ES100 POWER PLAN - SITE OVERALL
EG100 GROUNDING PLAN - SITE OVERALL
EG101 PARTIAL GROUNDING PLAN - SITE NORTH
EG102 PARTIAL GROUNDING PLAN - SITE SOUTH
EG200 LIGHTNING PROTECTION PLAN - SITE OVERALL
EL100 LIGHTING PLAN - BASEMENT OVERALL
EL110 LIGHTING PLAN - FIRST CATWALK AND SUB-FLOOR ACCESS OVERALL
EL120 LIGHTING PLAN - FIRST FLOOR OVERALL
EL121 PARTIAL LIGHTING PLAN - FIRST FLOOR AREA A
EL122 PARTIAL LIGHTING PLAN - FIRST FLOOR AREA B
EL123 PARTIAL LIGHTING PLAN - FIRST FLOOR AREA C
EL130 LIGHTING PLAN - SECOND CATWALK OVERALL
EL140 LIGHTING PLAN - PLATFORM OVERALL
EP100 POWER PLAN - BASEMENT OVERALL
EP110 POWER PLAN - FIRST CATWALK AND SUB-FLOOR ACCESS OVERALL
EP120 POWER PLAN - FIRST FLOOR OVERALL
EP121 PARTIAL POWER PLAN - FIRST FLOOR AREA A
EP122 PARTIAL POWER PLAN - FIRST FLOOR AREA B
EP123 PARTIAL POWER PLAN - FIRST FLOOR AREA C
EP130 POWER PLAN - SECOND CATWALK OVERALL
EP221 PARTIAL EQUIPMENT PLAN - FIRST FLOOR AREA A
EP222 PARTIAL EQUIPMENT PLAN - FIRST FLOOR AREA B
EP223 PARTIAL EQUIPMENT PLAN - FIRST FLOOR AREA C
E-200 EQUIPMENT ELEVATIONS
E-401 ENLARGED POWER PLANS
E-501 DETAILS
E-502 DETAILS
E-601 ONE-LINE DIAGRAM
E-602 ONE-LINE DIAGRAM - CRITICAL LOADS
E-603 ONE-LINE DIAGRAM - MECHANICAL
E-604 DC ONE-LINE DIAGRAM
E-610 SEQUENCE OF OPERATIONS
E-701 LIGHTING SCHEDULES
E-702 EQUIPMENT DATA SCHEDULE
E-703 PANELBOARD SCHEDULES - AREA A
E-704 PANELBOARD SCHEDULES - AREA A
E-705 PANELBOARD SCHEDULES - AREAS B AND C
E-706 PANELBOARD SCHEDULES - AREAS B AND C
E-710 POWER MONITORING SYSTEM MATRIX
TELECOMMUNICATIONS
T-001 SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
TS100 TELECOM PLAN - SITE OVERALL
TS101 PARTIAL TELECOM PLAN - SITE
TS102 PARTIAL TELECOM PLAN - SITE
TS103 PARTIAL TELECOM PLAN - SITE
TS104 PARTIAL TELECOM PLAN - SITE
TS105 PARTIAL TELECOM PLAN - SITE
TS106 PARTIAL TELECOM PLAN - SITE
TS107 PARTIAL TELECOM PLAN - SITE
TS501 DETAILS - SITE
TS502 DETAILS - SITE
T-120 TELECOM PLAN - FIRST FLOOR OVERALL
T-121 PARTIAL TELECOM PLAN - FIRST FLOOR AREA A
T-122 PARTIAL TELECOM PLAN - FIRST FLOOR AREA B
T-123 PARTIAL TELECOM PLAN - FIRST FLOOR AREA C
T-201 RACK ELEVATIONS
T-202 RACK ELEVATIONS
T-203 RACK ELEVATIONS
T-204 RACK ELEVATIONS
T-205 WALL ELEVATIONS
T-206 WALL ELEVATIONS
T-207 AV MONITOR ELEVATIONS
T-208 AV MONITOR ELEVATIONS
T-401 ENLARGED PLANS
T-402 ENLARGED PLANS
T-403 ENLARGED PLANS
T-404 ENLARGED PLANS
T-405 ENLARGED PLANS
T-406 ENLARGED PLANS
T-407 ENLARGED PLANS
T-408 ENLARGED PLANS
T-409 ENLARGED AV PLANS
T-501 DETAILS - DATA
T-502 DETAILS - DATA
T-503 DETAILS - DATA
T-601 ONE-LINE DIAGRAM
T-610 AUDIO-VISUAL DIAGRAMS
T-611 AUDIO/VISUAL DIAGRAM - CLASSROOM 136
T-612 AUDIO/VISUAL DIAGRAM - OPS WORKSTATIONS 140
Sheet Number Sheet Name
GENERAL
G-001b COVER SHEET - VOLUME II G-002b SHEET INDEX - VOLUME II
FIRE SUPRESSION
FX001 GENERAL NOTES
FX120 FIRE SUPPRESSION PLAN FIRST FLOOR OVERALL
FX121 PARTIAL FIRE SUPPRESSION PLAN FIRST FLOOR AREA A
FX122 PARTIAL FIRE SUPPRESSION PLAN FIRST FLOOR AREA B
FX123 PARTIAL FIRE SUPPRESSION PLAN FIRST FLOOR AREA C
FX501 FIRE SUPPRESSION DETAILS
FX502 FIRE SUPPRESSION DETAILS
FIRE ALARM
FA001 GENERAL NOTES
FA120 FIRE ALARM PLAN FIRST FLOOR OVERALL
FA121 PARTIAL FIRE ALARM PLAN FIRST FLOOR AREA A
FA122 PARTIAL FIRE ALARM PLAN FIRST FLOOR AREA B
FA123 PARTIAL FIRE ALARM PLAN FIRST FLOOR AREA C
FA501 FIRE ALARM DETAILS
FA502 FIRE ALARM DETAILS
PLUMBING
P-001 ABBREVIATIONS, SYMBOLS, AND GENERAL NOTES
PS100 PLUMBING SITE PLAN
P-100 UNDERFLOOR PLAN - BASEMENT OVERALL
P-101 PARTIAL UNDERFLOOR PLAN - FIRST FLOOR AREA A
P-102 PARTIAL UNDERFLOOR PLAN - BASEMENT AREA B
P-103 PARTIAL UNDERFLOOR PLAN - BASEMENT AREA C
P-120 FLOOR PLAN FIRST FLOOR - OVERALL
P-121 PARTIAL FLOOR PLAN - FIRST FLOOR AREA A
P-122 PARTIAL FLOOR PLAN - FIRST FLOOR AREA B
P-123 PARTIAL FLOOR PLAN - FIRST FLOOR AREA C
P-401 ENLARGED PLANS
P-501 PLUMBING DETAILS
P-502 PLUMBING DETAILS
P-503 FUEL OIL DETAILS
P-601 SCHEDULES
P-602 SCHEDULES
P-701 FLOW DIAGRAMS
P-702 PLUMBING ISOMETRICS
P-703 PLUMBING ISOMETRICS
P-704 FUEL OIL ISOMETRIC
MECHANICAL
M-001 ABBREVIATIONS, SYMBOLS AND GENERAL NOTES
M-002 ABBREVIATIONS, SYMBOLS AND GENERAL NOTES
MH120 DUCT PLAN - FIRST FLOOR OVERALL
MH121 PARTIAL DUCT PLAN - FIRST FLOOR AREA A
MH122 PARTIAL DUCT PLAN - FIRST FLOOR AREA B
MH123 PARTIAL DUCT PLAN - FIRST FLOOR AREA C
MP110 PIPING PLAN - FIRST CATWALK AND SUB-FLOOR ACCESS OVERALL
MP130 PIPING PLAN - FIRST FLOOR OVERALL
MP131 PARTIAL PIPING PLAN - FIRST FLOOR AREA A
MP132 PARTIAL PIPING PLAN - FIRST FLOOR AREA B
MP133 PARTIAL PIPING PLAN - FIRST FLOOR AREA C
M-140 ROOF PLAN - OVERALL
M-301 SECTIONS
M-302 SECTIONS
M-303 3-D VIEWS
M-401 ENLARGED PLANS
M-402 ENLARGED PLANS
M-501 DETAILS
M-502 DETAILS
M-503 DETAILS
M-601 SCHEDULES
M-602 SCHEDULES
M-701 AIR FLOW DIAGRAMS
M-702 AIR FLOW DIAGRAMS
M-703 AIR FLOW DIAGRAMS
M-704 HOT WATER ISOMETRIC - AREA A
M-705 CHILLED & HEATING WATER ISOMETRIC - AREA B
M-706 CHILLED & HEATING WATER ISOMETRIC - AREA C
M-801 BAS CONTROL DIAGRAMS
M-802 BAS CONTROL DIAGRAMS
M-803 BAS CONTROL DIAGRAMS
M-804 BAS CONTROL DIAGRAMS
M-805 BAS CONTROL DIAGRAMS
M-806 BAS CONTROL DIAGRAMS
M-807 BAS CONTROL DIAGRAMS
M-808 BAS CONTROL POINTS
M
AR
K D
E
SC
R
IP
TI
O
N D
A
TE
AM
EN
D
M
EN
T 0 0
D
EC
24' - 0"
RADOME OUTER
DIAMETER, BY MFR
RADOME FOUNDATION STEM WALL
VERIFY W/ RADOME MANF
315.2" WALL CENTERLINE RADIUS
CL
CONDENSER PAD
10' - 0"
V E
R
IF
Y W
R
A D
O M
E M
A N
F
M
IN
7' - 6"
6" MIN
C L
RADOME CONT FOUNDATION BELOW
A N
C H
O R
B O
L T
C
IR
C L E
NOTE: REFER TO CIVIL DRAWINGS FOR LOCATION
C O
N D
E N
S E
R P
A D
S-404
B3
S-404
A1
3' - 0" 3' - 0"EQ EQ EQ
(16) DP24-0
(12) DP24-0
B3
S-401
A3
S-401
15.00°
30.00°
30.00°
15.00°
90.00° TYP EA QUADRANT
6" SLAB-ON-GRADE
REINF W/#4 @ 12" OC
EA WAY
E Q
E Q
E Q
S-403
A1
MET ANTENNA CENTER
B3
S-403
D3
S-401
15.00°
33' - 2"
' - 7
' - 7
33' - 2"
A4
S-404
TYP
4' - 0"
R E
: C
IV
IL
' - 0
R E
: C
IV
IL
' - 0
SLOPE DOWN
STOOP
RE: /C3 S-503
SLOPE DOWN
4' - 0"
A4
S-402
TYP
R E
C
IV
IL
R E
C
IV
IL
144.00°
75.00°
6" 2' - 0" 6"
3' - 0"
M
IN
S E
E P
L A
N
EXP JT
(2)#9 EF
(5)#5 @ 8" OC
EF
(4)#9 BOT
#4 CLOSED
TIES @ 12"
OC
(2)#8 CONT T&B
#4 @ 16" OC
FINISHED GRADE
RE: CIVIL
RADOME ANTENNA FOUNDATION DESIGN WORST CASE LOAD
LOAD CASE TITLE LOAD CASE DESCRIPTION LOAD
DEAD LOAD ANTENNA WEIGHT 98,384 LBF
MAXIMUM DOWNWARD LOAD EL 60 DEG, 80 MPH WIND, +2" ICE + DEAD LOAD 160,452 LBF
MAXIMUM OVERTURNING MOMENT EL 0 DEG, 80 MPH REAR WIND, +2" ICE + DEAD LOAD 15,036,540 IN-LBF OR
1,253,045 FT-LBF
MAXIMUM HORIZONTAL SHEAR EL 0 DEG, 80 MPH REAR WIND, +2" ICE + DEAD LOAD 43,432 LBF
NOTE: 150 MPH WIND DOES NOT BOUND THE WORST CASE FOUNDATION LOADS CASE SINCE ANTENNA IS IN ZENITH
POSITION, ELEVATION = 90 DEGREES FOR STOW SURVIVAL CONDITIONS.
NOTES:
1. FOUNDATION DESIGN BASIS CONSIDERS AN/GSC-52B(V1)-(V6)/G LARGE FIXED HEMP TERMINAL AND LOADING PROVIDED WITHIN "FACILITY DESIGN CRITERIA FOR MODERNAIZATION OF ENTERPRISE TERMINALS BY PM WESS
GENERAL SHEET NOTES
1. ANTENNA FOUNDATION DESIGN IS PROVIDED WITHIN STRUCTURAL
DRAWINGS. ANTENNA TO BE PROVIDED BY GOVERNMENT. COORDINATE
LAYOUT OF ANTENNAS, TRENCHES, ETC WITH MRF.
SHEET KEYNOTES
6" 2' - 0" 6"
M
IN
S E
E P
L A
N
EXP JT
NOTE: REFER TO
FOR BALANCE OF INFO
/B3 S-401
DRILLED PIER -REF PLAN.
REINF REF DRILLED PIER
SCHED
(2)#8 CONT T&B RUN
INSIDE VERT PIER
REINF
FINISHED GRADE
RE: CIVIL
IFL TRENCH PENETRATION THRU RADOME FDN
2' - 0"
2" TYP
(4)#6 X 12'-0" LG
BARS CENTERED AT
TRENCH
@ 4" OC EA SIDE
(4)#4 TIES
STD FDN REINF
REF /B3 S-403
(4) EQ SPACINGS
#4 CLOSED TIES @ TRENCH
FINSHED GRADE FS
RE: CIVIL
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES:
S-401
E N
L A
R G
E D
P L A
N S
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
G .G
A R
R E
T T
/T .T
E S
F A
Y E
T .V
O L L M
E R
/G .G
A R
R E
T T
K D
IC
K
E N
S
R S
H
IN
N
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SCALE: 3/16" = 1'-0"A1
WEST MET ANTENNA AND RADOME FOUNDATION PLAN
SCALE: 1/2" = 1'-0"B3
RADOME FOUNDATION SECTION
01 2 42
SCALE: 1/2"=1'-0"
02 4 84
SCALE: 3/16"=1'-0"
SCALE: 1/2" = 1'-0"A3
RADOME FOUNDATION AT PIER
SCALE: 1/2" = 1'-0"D3
RADOME FDN @ IFL TRENCH
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
EC
S-404
B3
S-404
A1
B3
S-401
A3
S-401
S-403
A1
B3
S-403
D3
S-401
24' - 0"
RADOME OUTER
DIAMETER, BY MFR
RADOME FOUNDATION STEM WALL
VERIFY W
/ R
ADOME M
ANF
315.2" W
ALL C
ENTERLIN
E R
ADIU
S
C L
CONDENSER PAD
10' - 0"
V E
R
IF
Y W
R
A D
O M
E M
A N
F
M
IN
7' - 6"
6" MIN
CL
RADOME CONT FOUNDATION BELOW
A N
C H
O R
B O
L T
C
IR
C L E
NOTE: REFER TO CIVIL DRAWINGS FOR LOCATION
C O
N D
E N
S E
R P
A D
3' - 0"3' - 0" EQEQEQ
(16) DP24-0
(12) DP24-0
15.00°
30.00°
30.00°
15.00°
90.00° TYP EA QUADRANT
6" SLAB-ON-GRADE
REINF W/#4 @ 12" OC
EA WAY
E Q
E Q
E Q
MET ANTENNA CENTER
33' - 2"4' - 0"
5' - 7"
5' - 7"
4' -
33' -
OH
R E : C
IV
IL
5' - 0"
R E : C
IV
IL
5' - 0"
A4
S-404
SLOPE D
OW
N
STOOP R
E:
C3
S-5
SLOPE DOWNR
E
C
IV
IL
R E
C
IV
IL
A4
S-402
TYP
T Y
P
144.00°
90.00°
1' - 6"
#5 @ 12" OC
6" CONC SLAB WITH #4
@ 12: OC EA WAY,
CENTERED IN SLAB
THICKNESS
1' - 6"
#5 DWLS
@ 12" OC
3' - 0"
RADOM VESTIBULE
DOOR BY MFR
1'-0" MIN
DRAINAGE FILL
CONCRETE STOOP RE:
/C3 S-503
SLOPE DOWN
1" DIA x 18" LG
SMOOTH DOWEL @
12" OC. GREASE
ONE END
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
S-402
E N
L A
R G
E D
P L A
N S
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
G .G
A R
R E
T T
/T .T
E S
F A
Y E
T .V
O L L M
E R
/G .G
A R
R E
T T
K D
IC
K
E N
S
R S
H
IN
N
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SCALE: 3/16" = 1'-0"A1
EAST MET ANTENNA AND RADOME FOUNDATION PLAN
SCALE: 1/2" = 1'-0"A4
RADOME VESTIBULE FDN SECTION DOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
EC
CARD READER BACKBOX
FIXED POSITION CCTV CAMERA BACKBOX
pivCLASS CARD READER WITH KEYPAD BACKBOX
HIGH SECURITY SWITCH (PROVIDED BY DIV. 8)
24VDC ELECTRIFIED LOCKING HARDWARE REQUEST TO EXIT SENSOR BACKBOX
50" CCTV MONITOR BACKBOX
CR
EL
PIDS ALARM MONITORING WORKSTATION (GFGI)AWS
VINDICATOR SYSTEM PANEL ENCLOSUREACP
SECURITY SYMBOLS
J 120 VAC POWER (PROVIDED BY DIV. 26)
DATA CONNECTION (PROVIDED BY DIV. 27)
CAMERA INTERFACE BOXCIB
DOOR INTERFACE BOXDIB
BWS VINDICATOR ACS WORKSTATION (GFGI)
DOOR POSITION SWITCH (PROVIDED BY DIV. 8)
PANORAMIC PIR BACKBOX
FILTER BOX. CONSULT HEMP X SERIES DRAWINGS FOR FILTER BOX INFORMATION AND
DETAILS.
FB
PULL BOX
NS 48 PORT NETWORK SWITCH (GFGI)
KP IDS KEYPAD BACKBOX
AIB ALARM INTERFACE BOX (GFGI)
MASTER INTERCOM BACKBOX
D DURESS BUTTON BACKBOX
2" UNDERGROUND PVC CONDUIT
4" UNDERGROUND PVC CONDUIT
CWS VINDICATOR ACS WORKSTATION (GFGI) 4
FIELD VERIFY EQUIPMENT LOCATIONS PRIOR TO THE START OF INSTALLATION. ANY CONFLICTS
MUST BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE GOVERNMENT.
MINIMUM CONDUIT SIZE MUST BE 3/4" WITH THE EXCEPTION OF "DROP CONDUITS" AT DOOR
LOCATIONS, WHICH MAY BE 1/2". ALL CONDUITS MUST BE EMT WITH PULL STRING.
CONDUIT FILL MUST NOT EXCEED 40%. INSTALLATION OF CONDUIT AND WIRING SHALL BE IN
COMPLIANCE WITH NATIONAL ELECTRICAL CODE (NEC). ALL WIRING MUST BE HOMERUN,
UNLESS OTHERWISE NOTED.
SECURITY CONTROL CONDUCTORS MUST BE SHIELDED COPPER AND MINIMUM 18 AWG. UNLESS
OTHERWISE NOTED. SECURITY CONDUCTORS MUST NOT SHARE CONDUIT WITH CONDUCTORS
OF OTHER TRADES. SECURITY CONTRACTOR MUST BE RESPONSIBLE FOR ENSURING THAT HIGH
VOLTAGE (120 VAC) POWER CONDUCTORS ARE NOT ROUTED WITHIN 12 INCHES OF SECURITY
CONTROL WIRING. ALL CONDUCTORS MUST BE COLOR CODED AND TAGGED AS DESCRIBED IN
THE WRITTEN SPECIFICATIONS AND APPROVED BY THE PROJECT MANAGER.
CONFIRM FINAL MOUNTING LOCATION FOR EQUIPMENT WITH THE GOVERNMENT PRIOR TO
INSTALLATION.
CONDUITS PENETRATING FIRE AND HEMP RATED WALLS OR FLOOR MUST USE U.L. APPROVED
DEVICES IN ORDER TO MAINTAIN RATING.
MAINTAIN ALL CABLE MINIMUM BENDING RADII ACCORDING TO THE CABLE MANUFACTURER.
ALL WORK MUST COMPLY WITH ALL APPLICABLE CODES, AMENDMENTS, RULES, REGULATIONS,
ORDINANCES, LAWS, ORDERS, APPROVALS, ETC. THAT ARE REQUIRED BY PUBLIC AUTHORITIES.
IN THE EVENT OF CONFLICT, THE MOST STRINGENT REQUIREMENTS MUST GOVERN.
CONDUITS FOR COPPER FED CAMERAS MUST BE ROUTED IN SUCH A MANNER SO AS TO NOT
EXCEED 295' OR THE DISTANCE NOTED ON THE DRAWINGS. BRING TO THE ATTENTION OF THE
GOVERNMENT ANY CONDUIT RUN WITH EXCEEDS THIS DISTANCE BEFORE INSTALLING CONDUIT
AND/OR CABLING.
DOOR INTERFACE AND CAMERA INTERFACE BOXES CONDUITS TO COMM ROOMS MUST ALL BE
HOMERUN. CONTRACTOR MUST NOT COMBINE MORE THAN THREE PORTALS AND MUST NOT
COMBINE ESS CONDUITS WITH ANY OTHER SYSTEM CONDUITS.
CONSULT HEMP X SERIES DRAWINGS WHEN MOUNTING TO OR PENETRATING THE HEMP WALL.
FOR THIS MILCON PROJECT, ACTIVE DEVICES AND EQUIPMENT SUPPORTING THE ESS SUCH AS
CENTRAL PROCESSING UNITS, CONTROL PANELS, INTERIOR SENSORS,
COMMUNICATIONS/SECURITY CABLING, CAMERAS, ETC. ARE NOT IN CONTRACT (NIC) AND
FUNDED THROUGH OTHER APPROPRIATIONS, WITH EXCEPTION TO OSP FIBER OPTIC CABLE
BETWEEN THE EXISTING BASE ESS HEAD-END SYSTEM LOCATION AND THE PROJECT'S NEW
SYSTEM LOCATION WHICH IS INCLUDED IN THIS MILCON PROJECT CONTRACT.
THIS MILCON PROJECT'S FUNDING COVERS INTERIOR AND EXTERIOR INFRASTRUCTURE SUCH
AS CONDUIT/DUCT BANKS, JUNCTION BOXES, ENCLOSURES, RACKS, PEDESTALS, POLES/BASES, HAND-HOLES/MANHOLES, ELECTRIFIED DOOR HARDWARE, HEMP PENETRATIONS, SIGNAL/POWER HEMP FILTERS, POWER AND GROUNDING CONNECTIONS, ETC.
INFRASTRUCTURE SHALL COMPLY WITH UFC 4-021-02 AND AFI 31-101 REQUIREMENTS.
• ELECTRONIC PHYSICAL ACCESS CONTROL (EPACS), CLOSED CIRCUIT TELEVISION
(CCTV), AND INTRUSION DETECTION SYSTEM (IDS): ALL INFRASTRUCTURE IS PROVIDED
BY THE DIV. 26 CONTRACTOR, WITH EXCEPTION TO ELECTRIFIED DOOR HARDWARE TO
BE PROVIDED BY THE DIV. 8 CONTRACTOR AND OSP FIBER TO BUILDING 500 BY DIV. 27
CONTRACTOR.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
SECURITY GENERAL NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
TY001
E L E
C T
R O
N
IC
S E
C U
R
IT
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
S Y
M B
O L S
A N
D G
E N
E R
A L N
O T
E S
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
R C
R A
IG
M M
C C
U L L O
U G
H
K D
IC
K
E N
S
S E
L L
IO
T T
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SECURITY DEVICE SCHEDULE
DEVICE
NO.
DOOR
NO. DIB NO. DETAIL NO. AREA
R01 100A D01 A1 - TY501 A
R02 121 D02 A1 - TY501 A
R03 122 D03 A1 - TY501 A
R04 107A D04 A1 - TY501 A
R05 130A D05 C1 - TY501 A
R06 130B D06 C1 - TY501 B
R07 139A D07 C1 - TY501 B
R09 139B D09 C1 - TY501 B
R10 150B D10 A1 - TY501 B
R11 127A D08 A1 - TY501 A
R16 130B D06 C1 - TY501 B
R17 139A D07 C1 - TY501 B
R18 139B D09 C1 - TY501 C
R19 130A D05 C1 - TY501 A
R20 139C D11 C1 - TY501 B
R21 139C D11 C1 - TY501 B
R22 135 D12 C1 - TY501 C
R23 135 D12 C1 - TY501 C
S01 100A P03 A1 - TY501 A
S02 121 P03 A1 - TY501 A
S03 122 D03 A1 - TY501 A
S04 127B P03 C3 - TY501 A
S04 127B P03 C3 - TY501 A
S05 107A P03 A1 - TY501 A
S06 130A P03 C1 - TY501 A
S07 130B P03 C1 - TY501 B
S07 HATCH P03 B
S08 143B P03 A4 - TY501 B
S08 150D P03 C3 - TY501 B
S08 150D P03 C3 - TY501 B
S09 139A P03 C1 - TY501 B
S10 139C P03 C1 - TY501 B
S11 139B P03 C1 - TY501 B
S12 150B P03 A1 - TY501 B
S13 128A P03 C4 - TY501 A
S13 128A P03 C4 - TY501 A
S14 127A P03 A1 - TY501 A
S15 150E P03 A4 - TY501 B
S16 135 P02 C
S17 135 P02 C
S18 135 P03 C3 - TY502 C
S19 135 P03 C3 - TY502 C
DOOR INTERFACE BOX
SCHEDULE
DEVICE
NO.
DOOR
NO.
CONTROLLER
NO. AREA
D01 100A P01 A
D02 121 P01 A
D03 122 P01 A
D04 107A P01 A
D05 130A P01 A
D06 130B P01 B
D07 139A P01 B
D08 127A P01 A
D09 139B P01 C
D10 150B P01 B
D11 139C P01 B
D12 135 P01 C
D29 139 P01 B
D30 130 P01 B
D31 139C P01 B
CCTV DEVICE SCHEDULE
DEVIC
E NO.
CABLE
DISTANCE DETAIL NO. AREA
C01 61'-6" A1 - TY503 A
C02 113'-0" A1 - TY503 A
C03 21'-0" B1 - TY503 B
C04 116'-6" A1 - TY503 B
C05 69'-0" B1 - TY503 B
C06 114'-0" B1 - TY503 B
C07 97'-0" B1 - TY503 C
C08 110'-0" A1 - TY503 C
C09 27'-0" B1 - TY503 A
C10 114'-0" B1 - TY503 B
MOTION SENSOR
SCHEDULE
DEVICE
NO.
ROOM
NO.
CONTOLLER
NO. ZONE
M02 131 P03 2
M03 139 P03 3
M04 135 P03 4
M05 135 P03 4
D13 - P01 SITE
D14 - P01 SITE
D15 - P01 SITE
D16 - P01 SITE
D17 - P01 SITE
D18 - P01 SITE
D19 - P01 SITE
D20 - P01 SITE
D21 - P01 SITE
D22 - P01 SITE
D23 - P01 SITE
D24 - P01 SITE
D25 - P01 SITE
D26 - P01 SITE
D27 - P01 SITE
D28 - P01 SITE
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
E C
TY101
L E
C T
R O
N
C
U R
I T
Y
S
Y S
T E
M
I N
F R
A S
T R
U C
T U
A
N
S I T
E
R
C
R A
I G
M
M
C C
U L
L O
U G
H
S
E
L L
I O
T T
1'-0" = 25'-0"
A1
ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - SITE
READY TO ADVERTISE
O
C T
O B
US Army Corps of Engineers ®
SHEET ID
M
Y
C
O R
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
F I
M
E
I S
S U
E
D
A T
E
C O
N T
R A
S O
L I C
I T
A T
I O
N
N
O
F I
M
B E
R
1 2 3 4 5
D
C
B
A
O F
F U
R
S
E
N
E B
R A
S K
A
S A
T C
I L S
T A
R
F
A C
I L I T
Y
P R
O J E
S
G B
P
O M
A H
A
D
I S
T R
I C
T
C
A P
I T
A L
A
V E
S
T E
O M
A H
A
N
E
N
O R
O
A D
W A
Y
S T
L O
U I S
M
I S
S O
U R
I
D E
S C
R I P
T I O
N D
A T
E
W F
F
W F
D
M A
R K
SCALES:
NOT FOR CONSTRUCTION
NOT FOR CONSTRUCTION
K
D
I C
K E
N S
TRUE NORTH
1. PROVIDE INFRASTRUCTRE AT EACH LIGHT POLE FOR GFGI
CAMERAS. CONSULT TY-502 FOR DETAILS.
GENERAL SHEET NOTES
75'50'0 25'
SCALE: 1" = 25'-0"
A M
E N
D M
E N
T
D
X
X
X
X
X
X
X
X
X
X X
X X
X
X
X
X
X
X
X
X
CO
CO
CO
CO
CO
CO
CO
CO
COCOCO
CO
CO
CO
CO
CO
C
B
C
B
D
D
D
D
D
CO
CO
GND
GND
GND
GND
G
H T
F I X
T U
R E
S M
O K
E
D
E T
S
S
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
GND
C O
M S
I V
E
SATCOM-MILSTAR
MET-1
MET-2
RT PAD
HF ANTENNA
HF ANTENNA
(ON ROOF)
TY502
A1
TY503
A4
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
CIB
D28
D13
D14
D15
D16
D17
D18
D19
D20
D21
D22
D23
D24
D25
D26
D27
4" UNDERGROUND
PVC CONDUIT
2" UNDERGROUND
PVC CONDUIT
STUB UP INTO
ROOM 122
CR
CR
TY502
A3
RT HUTDOOR CONTACT
B C D E F G H J
G.9
G.1F.4E.9E.1D.4D.1C.4 E.5
TY123
A2
TY122
A2
TY121
A1
GENERAL SHEET NOTES
SHEET KEYNOTES
1. SEE TY001 FOR SYMBOLS AND GENERAL NOTES.
PLAN
NORTH
T R
U E
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES: KEY PLAN:
B C
A
TY120
E L E
C T
R O
N
IC
S E
C U
R
IT
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
P L A
N F
IR
S
T F
L O
O R
O
V E
R A
L L
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
S H
A N
S B
E R
R Y
B A
R T
E R
B U
R N
K D
IC
K
E N
S
J H
E
IT
Z
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
08 16 3241216
SCALE: 1/16"=1'-0"
SCALE: 1/16" = 1'-0"A1
ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST FLOOR OVERALL
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A M
E N
D M
E N
T
D
EC
CR
CR
CR
CR
EL
DIB
EL DIB
EL DIB
EL
DIB
ELDIB
CR
EL DIB
ACP
CR
CIB
C D E F G H J
G.9
9.7
G.1F.4E.9E.1D.4D.1C.4
9.5
PHYSICAL
FITNESS
BREAK ROOM
CLASSROOM
MEN'S
WOMEN'S
MEN'S
WOMEN'S
WELLNESS ROOM
JANITORS
CORRIDOR
CORRIDOR
OFFICE
OFFICE
OFFICE
102ENTRANCE
VESTIBULE
WORKROOM
MECHANICAL
GARAGE
127 STORAGE
ELECTRICAL
CORRIDOR
TELECOM
LOCKERS
100A
M A
T C
H L
IN
E
A
T Y
M A
T C
H L
IN
E
A
T Y
E.5
SECURITY
107A
SECURITY EQUIPMENT RACK
TY401
A1
R01
S01
D01
R02
S02
D02
S03
D03
R03
130A S06
R05
D05
R04
S05
D04
127B
S04
C01
C02
C03
128A
127A
S13
S13
R11
S14
D08
P01
C09 S04
GENERAL SHEET NOTES
SHEET KEYNOTES
1. SEE TY001 FOR SYMBOLS AND GENERAL NOTES.
PLAN
NORTH
T R
U E
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES: KEY PLAN:
A
TY121
E L E
C T
R O
N
IC
S E
C U
R
IT
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
P L A
N F
IR
S
T F
L O
O R
A
R E
A A
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
R C
R A
IG
M M
C C
U L L O
U G
H
K D
IC
K
E N
S
S E
L L
IO
T T
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SCALE: 1/8" = 1'-0"A1
ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST FLOOR AREA A
04 8 16268
SCALE: 1/8"=1'-0"
1 SITE SECURITY CONDUIT STUB UP LOCATION.
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
EC
CR
CR
CR
EL
DIB
EL
DIB
EL
EL
DIB
DIB
EL
DIB
CR
CR
EL
DIB CR
CR
CR
CR
CIB
CIB
CIB
A
B C D E
E.1D.4D.1C.4
SWITCH
BATTERIES / UPS
BATTERIES / UPS
GENERATOR
MECHANICAL
OPS FLOOR
WORKSTATIONS
VESTIBULE
OBSERVATION
SPACE
130B
139B
139C
150B
M A
T C
H L
IN
E
A
T Y
M A
T C
H L
IN
E
A
T Y
143B
130A
SWITCH
ELECTRICAL
S08
R05S06
D05
R06
S07
D06
139A
D07
S09 R07
S10 R09
S11
D09
D10
S12
R10
C04
C05
C03
C07
C08
150E
S15
M02
CORRIDOR
M03
FB
FB
FB
M04
CHILLER
KP
R16
KP
R17
D11
FB
R18
KP
C10
BWS
R19
R20
R21
C09
150D
S08
S08
S07
FB
AWS
CWS
J
J
J
J
J
D30 4
D29
D31
GENERAL SHEET NOTES
SHEET KEYNOTES
1. SEE TY001 FOR SYMBOLS AND GENERAL NOTES.
PLAN
NORTH
T R
U E
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES: KEY PLAN:
B
TY122
E L E
C T
R O
N
IC
S E
C U
IR
T
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
P L A
N F
IR
S
T F
L O
O R
A
R E
A B
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
R C
R A
IG
M M
C C
U L L O
U G
H
K D
IC
K
E N
S
S E
L L
IO
T T
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SCALE: 1/8" = 1'-0"A2
ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST FLOOR AREA B
04 8 16268
SCALE: 1/8"=1'-0"
2 ELECTRIC INTERLOCKING DEVICES SHALL BE PROVIDED FOR VESTIBULES
EQUIPPED WITH SHIELDED DOORS AT EACH END. ELECTRIC INTERLOCKING
DEVICES SHALL BE PROVIDED SO THAT SHIELDED DOORS AT THE ENDS OF THE
VESTIBULE CANNOT BE OPENED AT THE SAME TIME DURING NORMAL
OPERATION. A MANUAL OVERRIDE SHALL BE PROVIDED TO ALLOW
EMERGENCY EGRESS, AND AN AUDIBLE ALARM SHALL BE PROVIDED TO
INDICATE THAT DOORS AT EACH END OF THE VESTIBULE ARE OPEN. THE
ALARM WILL CONTINUE TO SOUND WHILE BOTH DOORS ARE OPEN.
5 USE THE OBSERVATION SPACE CORRIDOR AS THE PATHWAY FOR THE CAMERA
CIRCUITS. THE CIRCUITRY WILL NOT PENETRATE THE HEMP ENCLOSURE. M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A
M E
N D
M E
N T
D
EC
4 5
EL
DIB
ACP
CR
AIB AIB
CR
CR
CR
EL DIB
CR
CR
D
IDS
CIB
CIB
E F G H J
G.9
G.1F.4E.9E.1
OPS FLOOR
SUPPLY ROOM
138WORKROOM
CLASSROOM
JANITOR
WOMEN'S
MEN'S
M A
T C
H L
IN
E
A
T Y
M A
T C
H L
IN
E
A
T Y
E.5
C08
C07
B1
TY401
OPS FLOOR
WORKSTATIONS
P02
S16 S17
3 3139B D09
FB
M04
R18
CR
S11
R09
D12FB
M05
R22
R23
S18
S19
P03
GENERAL SHEET NOTES
SHEET KEYNOTES
1. SEE TY001 FOR SYMBOLS AND GENERAL NOTES.
PLAN
NORTH
T R
U E
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES: KEY PLAN:
C
TY123
E L E
C T
R O
N
IC
S E
C U
R
IT
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
P L A
N F
IR
S
T F
L O
O R
A
R E
A C
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
R C
R A
IG
M M
C C
U L L O
U G
H
K D
IC
K
E N
S
S E
L L
IO
T T
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SCALE: 1/8" = 1'-0"A2
ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - FIRST FLOOR AREA C
04 8 16268
SCALE: 1/8"=1'-0"
3 LOCATED UNDER RAISED FLOOR
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
EC
B C D E
E.1D.4D.1C.4
B.4 C.1 C.7 D.5
2.9
4.1
5.3
C06
GENERAL SHEET NOTES
SHEET KEYNOTES
1. SEE TY001 FOR SYMBOLS AND GENERAL NOTES.
PLAN
NORTH
T R
U E
N
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES: KEY PLAN:
B
TY124
E L E
C T
R O
N
IC
S E
C U
IR
T
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
P L A
N F
IR
S
T F
L O
O R
A
R E
A B
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
R C
R A
IG
M M
C C
U L L O
U G
H
K D
IC
K
E N
S
S E
L L
IO
T T
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
04 8 16268
SCALE: 1/8"=1'-0"
SCALE: 1/8" = 1'-0"A2
ELECTRONIC SECURITY SYSTEM INFRASTRUCTURE PLAN - ROOF AREA B
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
EC
C1
TY401
SECURITY EQUIPMENT RACK
SECURITY WIREWAY
C3
TY401
FIRST FLOOR
0' - 0"C1
NETWORK SWITCH
(GFGI)
MONITOR
(GFGI)
1U KEYBOARD SHELF
NVR (GFGI)
POWER STRIP
UPS
POWER STRIP
CABLE RACK
PLYWOOD BACKBOARD
CPU/MONITOR SHELF
WITH SINGLE SLIDING
KEYBOARD TRAY
(GFGI)
EQUIPMENT RACK
(PROVIDED BY DIV. 27)
CCTV PATCH PANEL
CENTRAL EXCHANGE
UNIT (GFGI)
FIRST FLOOR
100' - 0"
FIRST FLOOR
0' - 0"
NEMA 4 36"x30"
ENCLOSURE
SECURITY WIREWAY
2" CONDUIT
CABLE RACK
FIRST FLOOR
100' - 0"
FIRST FLOOR
0' - 0"
NEMA 4 36"x30"
ENCLOSURE
SECURITY WIREWAY
2" CONDUIT
FIRST FLOOR
100' - 0"
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
SCALES:
TY401
E L E
C T
R O
N
IC
S E
C U
R
IT
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
P L A
N E
N L A
R G
E D
P L A
N S
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
R C
R A
IG
M M
C C
U L L O
U G
H
K D
IC
K
E N
S
S E
L L
IO
T T
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
02 4 8134
SCALE: 1/4"=1'-0"
SCALE: 1/4" = 1'-0"A1
ELECTRONIC SECURITY SYSTEM PLAN - SECURITY ROOM 122
SCALE: NOT TO SCALEC1
SECURITY ROOM 122 RACK ELEVATION
SCALE: NOT TO SCALEC3
SECURITY ROOM 122 ACS ENCLOSURE ELEVATION
SCALE: NOT TO SCALEB1
OPS FLOOR 135 ACS ENCLOSURE ELEVATION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D
EC
8"
1-1/4"C TO NEAREST ACP
FINISHED
CEILING LINE
48"
UNSECURED SIDE
FLOOR LINE FLOOR LINE
FINISHED
CEILING LINE 2
8"
48"
SECURED SIDE
3/4"C
DOOR INTERFACE BOX
HIGH SECURITY SWITCH (PROVIDED BY DIV. 8)
3 24VDC ELECTRIFIED LOCKING HARDWARE (PROVIDED BY DIV. 8)
4 CARD READER (GOVERNMENT FURNISHED, GOVERNMENT INSTALLED)
5 CARD READER BACKBOX
FINISHED CEILING
LINE
FLOOR LINE
SECURED SIDE
WIDE GAP DOOR CONTACT SWITCH
SINGLE GANG BOX FOR CONNECTION OF DPS FLEX CONDUIT
3/4" CONDUIT TO NEAREST DIB
3/4" CONDUIT
3/4" CONDUIT TO NEAREST DIB
3/4" CONDUIT
8"
1-1/4"C TO NEAREST ACP
48"
UNSECURED SIDE
FLOOR LINE FLOOR LINE
8"
48"
SECURED SIDE
3/4"C
DOOR INTERFACE BOX
HIGH SECURITY SWITCH (PROVIDED BY DIV. 8)
3 24VDC ELECTRIFIED LOCKING HARDWARE
4 CARD READER BACKBOX
5 FILTER BOX
3/4"C
HIGH SECURITY SWITCH (PROVIDED BY DIV. 8)1
FLOOR LINE
3/4"C TO NEAREST DIB
SECURED SIDE
FINISHED
CEILING LINE 1 1
3/4"C TO NEAREST DIB
FLOOR LINE
FINISHED
CEILING LINE 1
SECURED SIDE
HIGH SECURITY SWITCH (PROVIDED BY DIV. 8)1
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
TY501
E L E
C T
R O
N
IC
S E
C U
R
IT
Y S
Y S
T E
M
IN
F R
A S
T R
U C
T U
R E
D E
T A
IL
S
O F
F U
T T
A
IR
F O
R C
E B
A S
E N
E B
R A
S K
A S
A T
C O
M
M
IL
S T
A R
F A
C
IL
IT
Y
P R
O J E
C T
N O
S
G B
P
O M
A H
A D
IS
T
R
IC
T C
A P
IT
A
L A
V E
S
T E
O M
A H
A N
E
N
O R
T H
B R
O A
D W
A Y
S T
L O
U
IS
M
IS
S
O U
R I
R C
R A
IG
M M
C C
U L L O
U G
H
K D
IC
K
E N
S
S E
L L
IO
T T
O
C T
O B
E R
W F
F
W F
D
READY TO ADVERTISE
SCALE: NOT TO SCALEA1
SINGLE DOOR WITH CARD READER
SCALE: NOT TO SCALEC3
OVERHEAD DOOR INTRUSION DETECTION
SCALE: NOT TO SCALEC1
HEMP ENTRY SINGLE DOOR WITH CARD READER
SCALE: NOT TO SCALEC4
DOUBLE DOOR INTRUSION DETECTION
SCALE: NOT TO SCALEA4
SINGLE DOOR INTRUSION DETECTION
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
A
M E
N D
M E
N T
D E
C
1. SECURITY CONDUITS AND BACKBOXES MUST BE RECESSED EXCEPT ON
THE HEMP SHIELD THEY MUST BE SURFACE MOUNTED.
GENERAL NOTES
ROAD
CURB
2’ - 0” DIA.
CONCRETE FOOTING WITH (6)
#5 VERT. EQUAL SPACED AND
#4 TIES @ 12-INCHES O.C. EXCEPT PLACE
TOP (3) TIES @ 3-INCHES O.C. WITH 3-INCH
CONCRETE COVER
1-INCH CONDUIT TO TURNSTILE
AND GATE
CARD READER
AND/OR VIDEO
INTERCOM IN
HOUSING
BASE PLATE
ANCHOR BOLT
2’ - 0”
TWO 1-INCH CONDUITS TO
SECURITY ROOM 122 VIA
MAINTENANCE HOLE
EXOTHERMIC WELD
CONNECTION
#6 BARE GROUND CONDUCTOR
3/4-INCH, 10'-0" LONG
GROUNDING ROD
PROVIDE CARD READER PEDESTAL. PEDESTAL
REQUIREMENTS INCLUDE MINIMUM
3-INCH SQUARE, 11 GAUGE TUBING. CARD READER AND
INTERCOM HOUSING MUST BE A MINIMUM OF 12 GAUGE.
EVERYTHING MUST BE ZINC PLATTING AND POWDER COATED
BLACK.
ENLARGED VIEW
CARD READER (GFGI)
A/V STATION
(GFGI)
REFER TO
ENLARGED VIEW
TY502
C1
CARD READER
SECTIONAL BOX
WHEN REQUIRED
SKID RESISTANT
SURFACE
PULL SLOT
STAINLESS STEEL
HEX BOLT AND
WASHER
COMPACTED
EARTH
CRUSHED ROCK
-I
N C
H E
S
BOX AND
COVER
CONCRETE RING
AROUND BOX. SLOPE
RING AWAY FROM BOX.
HANDHOLE REQUIREMENTS:
1. HOUSING SHALL BE A POLYMER CONCRETE REINFORCED WITH A HEAVY WEAVE FIBERGLASS
REINFORCING WITH COMPRESSIVE STRENGTH OF NO LESS THAN 10,000 PSI.
2. COVER AND BOX SHALL WITHSTAND A SERVICE LOAD OF NO LESS THAN 15,000 LBS OVER A
10-INCH BY 10-INCH AREA.
3. PROVIDE STAINLESS STEEL BOLTS AND INSERTS.
4. PROVIDE WITH (2) 2 1/2-INCH MOUSEHOLES (ONE ON EACH…