W9128F21R0051 - Washrack - RTA Drawings - VOLUME II.pdf

PDF 44 MB Posted

Attached to
B-21 Washrack and Maintenance Hangar, Ellsworth AFB, South Dakota
Solicitation number
W9128F-21-R-0051
Issued by

About this file

This solicitation is for the construction of a B-21 washrack and maintenance hangar at Ellsworth Air Force Base in South Dakota. The Corps of Engineers is seeking proposals for all design and construction services required to build the facilities. Interested parties must access the full solicitation documents through the Projnet plan room using the provided quick add key, as file size limitations prevent posting on SAM.gov. Proposals are due by the date specified on Projnet. The solicitation includes details on the scope of work, evaluation criteria, and terms and conditions for awarding a firm fixed-price construction contract. Construction must be completed within 720 calendar days of the notice to proceed. This project aims to provide updated facilities for washing and maintaining the new B-21 bomber fleet at Ellsworth AFB.

View the file

Other files

File Type Posted
Am_0011.pdf PDF
Am_0010_Dwgs_Vol1.pdf PDF
Am_0010_Dwgs_Vol3.pdf PDF
Am_0010.pdf PDF
Am_0009.pdf PDF
Am_0008.pdf PDF
Am_0007.pdf PDF
Am_0006.pdf PDF
Am_0005.pdf PDF
Am_0004.pdf PDF
W9128F21R0051 - Washrack - RTA Drawings - VOLUME I-.pdf PDF
Am_0003.pdf PDF
W9128F21R0051 - Washrack - RTA Drawings - VOLUME III.pdf PDF
W9128F21R0051_Specifications_Am3.pdf PDF
Am_0002.pdf PDF
Am0001_W9128F21R0051.pdf PDF
21-R-0051_Specifications.pdf PDF
Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

US Army Corps of Engineers ®

SOLICITATION NO.:

CONTRACT NO.:

ISSUE DATE:

VOLUME:

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

THIS PROJECT WAS REVIEWED BY THE OMAHA DISTRICT OF THE US ARMY CORPS OF ENGINEERS. THE INITIALS OR SIGNATURES AND REGISTRATION DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE PROJECT DOCUMENTS WITHIN THE SCOPE OF THEIR EMPLOYMENT AS REQUIRED BY ER 1110-1-8152.

SIGNATURES AFFIXED BELOW INDICATE OFFICIAL RECOMMENDATION AND APPROVAL OF DRAWINGS IN THIS SET.

CHIEF, GEOTECHNICAL

ENGINEERING & SCIENCES BRANCH

DATE

CHIEF, DAM SAFETY PROD.

CENTER

DATE

CHIEF, DESIGN BRANCH DATE

CHIEF, HYROLOGIC

ENGINEERING BRANCH

DATE

DATECHIEF, ENGINEERING

DIVISION, P.E.

SUBMITTED BY:

CHIEF: ARCH. / INTER.

RA

SECTION

SUBMITTED BY:

CHIEF: CIVIL / ENVIR.

PE

SECTION

SUBMITTED BY:

CHIEF: ELEC.

PE

SECTION

SUBMITTED BY:

CHIEF: MECH.

PE

SECTION

SUBMITTED BY:

CHIEF: STRUCT.

PE

SECTION

SUBMITTED BY:

CHIEF: FUELS

RA

SECTION

SUBMITTED BY:

CHIEF: GEOT./DAM SAFETY

PE

SECTION

SUBMITTED BY:

CADD

PROJECT COORD.

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

G-003

C O

V E

R V

O L U

M E

A H

A N

K

IN

S

A H

A N

K

IN

S

B L E

G R

E

ID

W9128F-21-R-0051

XXXXXX XX X XXXX

OCTOBER 2021

ELLSWORTH AIR FORCE BASE, SD

B-21: WASHRACK AND MAINTENANCE HANGAR

(WASHRACK)

PN: FXBM1090404, FY 2022

10/22/202110-22-2021

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

G-004

IN

D

E X

T O

D R

A W

IN

G

S V

O L U

M E

A H

A N

K

IN

S

A H

A N

K

IN

S

B L E

G R

E

ID

VOLUME INDEX:

VOLUME 1: GENERAL, CIVIL, & STRUCTURAL

VOLUME 2: ARCHITECTURAL, INTERIORS, & FIRE PROTECTION

VOLUME 3: PLUMBING, MECHANICAL, ELECTRICAL, & TELECOMMUNICATIONS

INDEX TO DRAWINGS VOLUME 2

SHEET NO. SHEET NAME

A-703 SIGNAGE DETAILS

A-704 SIGNAGE DETAILS

A-710 OVERALL GROUND FLOOR FINISH & SIGNAGE PLAN

A-711 OVERALL SECOND FLOOR FINISH & SIGNAGE PLAN

A-712 GROUND FLOOR FINISH & SIGNAGE PLAN - AREA A

A-713 GROUND FLOOR FINISH & SIGNAGE PLAN - AREA B

A-714 GROUND FLOOR FINISH & SIGNAGE PLAN - AREA C

A-715 SECOND FLOOR FINISH & SIGNAGE PLAN - AREA A & C

A-761 MILLWORK DETAILS

INTERIORS

I-010 OVERALL GROUND FLOOR FURNITURE PLAN

I-101 GROUND FLOOR FURNITURE PLAN - AREA B

FIRE PROTECTION

F-001 LIFE SAFETY CODE AND CRITERIA

F-002 CODE COMPLIANCE PLAN

F-010 GROUND FLOOR LIFE SAFETY PLAN

FA001 FIRE ALARM NOTES, LEGEND AND ABBREVIATIONS

FA101 GROUND FLOOR FIRE ALARM PLAN - AREA A AND B

FA102 GROUND FLOOR FIRE ALARM PLAN - AREA C

FA103 GROUND FLOOR FIRE ALARM PLAN - AREA D AND E

FA104 GROUND FLOOR FIRE ALARM PLAN - HEAT DETECTION - AREA A

AND B

FA105 GROUND FLOOR FIRE ALARM PLAN - HEAT DETECTION - AREA D

AND E

FA401 FIRE ALARM ENLARGED PLANS AND DETAILS

FA501 FIRE ALARM DETAILS

FA601 FIRE ALARM ONE-LINE DIAGRAM

FA602 FIRE ALARM MATRIX

FA603 RELEASING SYSTEM ALARM CONTROL PANEL

FX001 FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS

FX002 FIRE SUPPRESSION SITE PLAN

FX101 GROUND FLOOR FIRE SUPPRESSION PLAN - AREA A AND B

FX102 GROUND FLOOR FIRE SUPPRESSION PLAN - AREA C

FX103 GROUND FLOOR FIRE SUPPRESSION PLAN - AREA D AND E

FX401 FIRE SUPPRESSION ENLARGED PLANS AND DETAILS

FX501 FIRE SUPPRESSSION RISER DIAGRAMS AND DETAILS

INDEX TO DRAWINGS VOLUME 2

SHEET NO. SHEET NAME

GENERAL

G-003 COVER VOLUME 2

G-004 INDEX TO DRAWINGS VOLUME 2

ARCHITECTURAL

AG001 ARCHITECTURAL LEGEND AND ABBREVIATIONS

AG002 ARCHITECTURAL GENERAL NOTES

AG003 ACCESSIBILITY INFORMATION

A-010 AIRCRAFT CLEARANCE REQUIREMENTS

A-011 AIRCRAFT CLEARANCE REQUIREMENTS SECTIONS

A-020 OVERALL GROUND FLOOR AIR BARRIER PLAN

A-021 OVERALL SECOND FLOOR AIR BARRIER PLAN

A-022 AIR BARRIER SECTIONS

A-023 AIR BARRIER SECTIONS

A-030 SECURITY PLAN

A-110 OVERALL GROUND FLOOR PLAN

A-111 GROUND FLOOR PLAN - AREA A

A-112 GROUND FLOOR PLAN - AREA B

A-113 GROUND FLOOR PLAN - AREA C

A-120 OVERALL MECHANICAL PLATFORM PLAN

A-150 OVERALL GROUND FLOOR REFLECTED CEILING PLAN

A-151 GROUND FLOOR REFLECTED CEILING PLAN - AREA A

A-152 GROUND FLOOR REFLECTED CEILING PLAN - AREA B

A-153 GROUND FLOOR REFLECTED CEILING PLAN - AREA C

A-160 OVERALL PLATFORM LEVEL REFLECTED CEILING PLAN

A-161 PLATFORM LEVEL REFLECTED CEILING PLAN - AREA A

A-162 PLATFORM LEVEL REFLECTED CEILING PLAN - AREA B

A-163 PLATFORM LEVEL REFLECTED CEILING PLAN - AREA C

A-170 OVERALL ROOF PLAN

A-171 ICE/WATER BARRIER LOCATIONS

A-180 BRICK LEDGE PLAN AND ELEVATIONS

A-201 EXTERIOR BUILDING ELEVATIONS

A-251 ENLARGED EXTERIOR ELEVATIONS

A-252 ENLARGED EXTERIOR ELEVATIONS

A-253 ENLARGED EXTERIOR ELEVATIONS

A-254 ENLARGED EXTERIOR ELEVATIONS

A-301 BUILDING SECTIONS

A-302 BUILDING SECTIONS

A-303 BUILDING SECTIONS

A-310 WALL SECTIONS

A-311 WALL SECTIONS

A-312 WALL SECTIONS

A-313 WALL SECTIONS

A-314 WALL SECTIONS

A-401 ENLARGED FLOOR PLANS AND ELEVATIONS

A-402 ENLARGED FLOOR PLANS AND ELEVATIONS

A-403 ENLARGED FLOOR PLANS AND ELEVATIONS

A-404 ENLARGED FLOOR PLANS AND ELEVATIONS

A-411 SHIPS LADDER PLANS AND SECTIONS

A-412 LADDER DETAILS

A-420 SUMP PUMP PLANS AND SECTIONS

A-421 TOILET PLANS AND ELEVATIONS

A-422 TOILET PLANS AND ELEVATIONS

A-423 TOILET PLANS AND ELEVATIONS

A-501 PARTITION TYPES

A-502 PARTITION TYPE DETAILS

A-503 PARTITION TYPE DETAILS

A-504 PENETRATION DETAILS

A-505 PENETRATION DETAILS

A-510 EXTERIOR WALL DETAILS

A-511 EXTERIOR WALL DETAILS

A-512 EXTERIOR WALL DETAILS

A-521 GENERAL EXTERIOR DETAILS

A-522 GENERAL EXTERIOR DETAILS

A-551 MISCELLANEOUS DETAILS

A-571 ROOF DETAILS

A-572 ROOF DETAILS

A-573 ROOF DETAILS

A-574 ROOF DETAILS

A-575 ROOF DETAILS

A-581 INTERIOR FINISH DETAILS

A-601 DOOR SCHEDULE

A-621 DOOR DETAILS

A-622 DOOR DETAILS

A-623 DOOR DETAILS

A-630 HANGAR DOOR PLAN

A-631 HANGAR DOOR SECTIONS

A-632 HANGAR DOOR SECTIONS

A-633 HANGAR DOOR DETAILS

A-634 HANGAR DOOR DETAILS

A-635 HANGAR DOOR DETAILS

A-636 HANGAR DOOR DETAILS

A-651 INSULATED TRANSULCENT WALL PANEL SCHEDULE AND TYPES &

LOUVER SCHEDULE AND TYPES

A-661 WINDOW & TRANSLUCENT WALL PANEL DETAILS

A-671 LOUVER DETAILS

A-701 ROOM FINISH SCHEDULE AND LEGEND

A-702 SIGNAGE SCHEDULE AND DETAILS

RIGID INSULATION

FACE BRICK

PLYWOOD

CONCRETE

MASONRY UNIT

CONCRETE

UNDISTURBED

EARTH

GROUT OR

GYPSUM BOARD

STEEL OR

FERROUS

GRAVEL

FINISHED WOOD

BATT INSULATION

DIMENSION

LUMBER

METAL STUD

BACKER ROD AND

SEALANT

ALUMINUM OR

NON-FERROUS

SAND, PLASTER, OR

PORTLAND CEMENT

COMPACTED

FILL

TERRAZZO

GRASS

MASONRY

PARTICLE BOARD

GLUED-LAMINATED WOOD

PLASTIC LAMINATE

NEW DOOR

NEW WALL (RE: PARTITION TYPE)

PLAN LEGEND:

ROOM NAME

ROOM NUMBER

PARTITION TYPE

DOOR NUMBER

WINDOW TAG

GLAZING TYPE

LOUVER TAG

GRID BUBBLE AND LINE

TOILET ACCESSORY TAG

L01

T-01

W101

WORK

1' - 0" A.F.F.

FURNITURE SYSTEM TAG

ROOM NAME

CEILING HEIGHT TAG

S2AA

W1

XXX SIGNAGE TAG

ZZZ MATERIAL/FINISH TAG

INSULATED TRANSLUCENT

PANEL TAG

TP-1

SECTION, DETAIL, AND ELEVATION SYMBOL IDENTIFIERS:

DRAWING SEQUENCE NUMBER INDICATES

WHERE TITLE IS LOCATED (MAY NOT BE

PRESENT IF CALLOUT AND TITLE ARE ON

THE SAME DRAWING)

LETTER AND NUMBER INDICATE

SHEET GRID COORDINATE OF VIEW

ONE OR TWO CHARACTER DISCIPLINE

DESIGNATOR (MAY NOT BE PRESENT IF

CALLOUT AND TITLE ARE ON DRAWINGS

WITHIN THE SAME DISCIPLINE)

LETTER AND NUMBER INDICATE

SHEET GRID COORDINATE OF VIEW

WALL SECTION CALLOUT EXAMPLE:

DETAIL CALLOUT EXAMPLE:

ELEVATION CALLOUT EXAMPLE:

SECTION, DETAIL, AND ELEVATION TITLE EXAMPLE:

EXTERIORINTERIOR

NORTH ARROW EXAMPLE:

LETTER AND NUMBER

INDICATE SHEET GRID

COORDINATE OF VIEW

SHEET NUMBER WHERE

SECTION IS DRAWN

LETTER AND NUMBER

INDICATE SHEET GRID

COORDINATE OF VIEW

SHEET NUMBER WHERE

SECTION IS DRAWN

BUILDING SECTION CALLOUT EXAMPLE:

VIEW REFERENCE EXAMPLE:

LETTER AND NUMBER INDICATE

SHEET GRID COORDINATE OF VIEW

SHEET NUMBER WHERE

SECTION IS DRAWN

LETTER AND NUMBER

INDICATE SHEET GRID

COORDINATE OF VIEW

SHEET NUMBER WHERE

DETAIL IS DRAWN

A-751

A1

A3

A4A2

VIEW TITLE

A1

N

VIEW TITLE

VIEW SCALE

VIEW SCALE BAR

SCALE: 1/8" = 1'-0" 0 4' 8' 16'

PLAN

NORTH

PLAN NORTH

TRUE NORTH

NORTH INDICATING

PLAN NORTH

NORTH ARROW INDICATING PLAN

NORTH AND TRUE NORTH

A1

A-311

A1

A-301

A1

A-311

A1

A-301

A1

A-301

A1

A-301

A1

A-201

A1

A-401

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

AG001

A R

C H

IT

E

C T

U R

A L L

E G

E N

D A

N D

A B

B R

E V

IA

T

IO

N

S

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

OTS OPEN TO STRUCTURE

-P-

PA PUBLIC ADDRESS

PERIM PERIMETER

PKG PACKAGE

PL PLATE

PLMB PLUMBING

PLYWD PLYWOOD

PROJ PROJECT

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PVC POLYVINYL CHLORIDE

-R-

R RADIUS

R/A RETURN AIR

RCP REFLECTED CEILING PLAN

RD ROOF DRAIN

RE: REFERENCE

RECP RECEPTACLE

REINF REINFORCED

REQ'D REQUIRED

REV REVISION

RH RIGHT HAND

RO ROUGH OPENING

-S-

S SOUTH

S/A SUPPLY AIR

SCHED SCHEDULE

SECT SECTION

SF SQUARE FOOT

SID STRUCTURAL INTERIOR DESIGN

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE, AS IN "SQ FT"

SSMR STANDING SEAM METAL ROOF

STC SOUND TRANSMISSION CLASS

STD STANDARD

STOR STORAGE

STRUCT STRUCTURAL

SUPP SUPPORT

SUSP SUSPENDED

SYS SYSTEM

-T-

TD TRENCH DRAIN

TECH TECHNICAL

THK THICKNESS

THRU THROUGH

TLT TOILET

TO TOP OF, AS IN "TO STEEL"

TP TRANSLUCENT PANEL

TYP TYPICAL

-U-

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UTIL UTILITY

-V-

VENT VENTILATE, VENTILATOR

VERT VERTICAL

VOL VOLUME

-W-

W WEST, WIDTH

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WATER HEATER

WT WEIGHT

FHC FIRE HOSE CABINET (WITH EXTINGUISHER &

BRACKET)

FHR FIRE HOSE REEL (WITH EXTINGUISHER &

BRACKET)

FIN FINISHED, FINISH

FLR FLOOR

FT FEET / FOOT

FV FIELD VERIFY

°F FAHRENHEIT

-G-

GA GAUGE

GALV GALVANIZED

GL GIRT LINE, GRID LINE, GRADE LINE, GLASS

GRTG GRATING

GYP GYPSUM

GYP BD GYPSUM BOARD

-H-

H HIGH

HC HANDICAP ACCESSIBLE

HD HAND

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATION & AIR CONDITIONING

-I-

ID INSIDE DIAMETER

IDS INTRUSION DETECTION SYSTEM

IN INCH

INSUL INSULATION

INT INTERIOR

-J-

JAN JANITOR'S CLOSET

-L-

L LEFT, LONG, LENGTH

LAB LABORATORY

LAT LATITUDE

LAV LAVATORY

LB or # POUND

LH LEFT HAND

LONG LONGITUDE

LVR LOUVER

-M-

M METER

MACH MACHINE

MAINT MAINTENANCE

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM, MINUTE

MISC MISCELLANEOUS

MM MILLIMETER

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

-N-

N NORTH

N/A NOT APPLICABLE

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTP NOTICE TO PROCEED

NTS NOT TO SCALE

-O-

OC ON CENTER

OD OUTSIDE DIAMETER

OFF OFFICE

OPNG OPENING

OPP OPPOSITE

-A-

A/E ARCHITECT/ENGINEER

ACOUST ACOUSTICAL

ADJ ADJACENT, ADJUSTABLE

AFF ABOVE FINISH FLOOR

AHJ AUTHORITY HAVING JURISDICTION

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE

ARCH ARCHITECTURE, ARCHITECT

-B-

BD BOARD

BITUM BITUMINOUS

BLDG BUILDING

BLKG BLOCKING

BO BOTTOM OF, AS IN "BO STEEL"

BTWN BETWEEN

-C-

CAB CABINET

CCTV CLOSED CIRCUIT TELEVISION

CID COMPREHENSIVE INTERIOR DESIGN

CJ CONTROL JOINT, CONSTRUCTION JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONSTR CONSTRUCTION

CONT CONTINUOUS

CONTR CONTRACT, CONTRACTOR

COORD COORDINATE

COR CONTRACTING OFFICER REPRESENTATIVE

CORR CORRUGATED OR CORRIDOR

-D-

DBL DOUBLE

DEMO DEMOLITION

DESCR DESCRIPTION

DET DETAIL

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DN DOWN

DR DOOR

DS DOWNSPOUT

DWG DRAWING

-E-

E EAST

EA EACH

EEW EMERGENCY EYEWASH

EEWS EMERGENCY EYEWASH & SHOWER

EF EXHAUST FAN

EJ EXPANSION JOINT

EL ELEVATION, AS IN HEIGHT

ELAST ELASTOMERIC

ELEC ELECTRIC / ELECTRICAL

ELEV ELEVATOR, OR ELEVATION AS IN NORTH ELEV

EQ EQUAL

EQUIP EQUIPMENT

ETC AND SO FORTH (ETCETERA)

EW EACH WAY

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION

EXT EXTERIOR

-F-

FD FLOOR DRAIN

FDN FOUNDATION

FE FIRE EXTINGUISHER WITH WALL BRACKET

FEC FIRE EXTINGUISHER CABINET

FF FINISH FLOOR

FF&E FURNITURE, FIXTURES & EQUIPMENT

ABBREVIATIONS SEE ADDITIONAL FINISH MATERIAL ABBREVIATIONS IN THE MATERIAL LEGEND, DRAWING A-701PLAN LEGENDCALL OUT IDENTIFICATION MATERIAL SYMBOLS

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

AG002

A R

C H

IT

E

C T

U R

A L G

E N

E R

A L N

O T

E S

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

ARCHITECTURAL GENERAL NOTES

50. ALL EXTERIOR WALL MOUNTED ELEMENTS OVER RIBBED METAL

PANEL MUST BE INSTALLED OVER 14GA, PAINTED, GALVANIZED

SHEET METAL. SEE DETAIL F7/A-522.

51. ALL METAL WALL PANELS MUST BE CONTINUOUS WITHOUT JOINTS

UNLESS NOTED OTHERWISE.

52. CONSTRUCTION FOR SECURE AREAS, AND SECURE AREA

MATERIAL AND COMPONENTS, MUST COMPLY WITH UFC 4-010-05

AND IC TECH SPECS FOR ICD/ICS 705 AND FULLY MEET AND PASS

ALL ACCREDITATION.

53. CONTRACTOR MUST PROVIDE ACOUSTICAL TESTING OF SECURE

AREAS IN ORDER TO DEMONSTRATE CONFORMANCE WITH

REQUIREMENTS INDICATED IN DOCUMENTS. CONTRACTOR MUST

HIRE AN INDEPENDENT ACOUSTICAL TESTING AGENCY TO

PERFORM ACOUSTICAL TESTS IN ACCORDANCE WITH ASTM

E336-20 STANDARD TEST METHOD FOR MEASUREMENT OF

AIRBORNE SOUND ATTENUATION BETWEEN ROOMS IN BUILDINGS.

TESTING MUST BE CONDUCTED TO DETERMINE THE APPARENT

SOUND TRANSMISSION CLASS (ASTC) AND APPARENT

TRANSMISSION LOSS (ATL) AS INDICATED IN THE ASTM STANDARD.

CONTRACTOR MUST PROVIDE ONE TEST PER SECURE AREA IN

THE PRESENCE OF THE CONTRACTING OFFICER AND SITE

SECURITY OFFICER. THE ACCREDITING OFFICER MUST BE

NOTIFIED IN ADVANCE AND HAVE THE OPTION TO ATTEND

TESTING IF POSSIBLE. TEST LOCATIONS IN THE BUILDING MUST BE

DETERMINED BY THE SITE SECURITY OFFICER. CONTRACTOR IS

RESPONSIBLE FOR PROVIDING A COMPLETE REPORT OF EACH

TEST IN ACCORDANCE WITH SECTION 13 OF ASTM E336.

CONTRACTOR MUST BE RESPONSIBLE FOR REMEDIATING FAILED

TESTS AND MUST HAVE FAILED LOCATIONS RE-TESTED TO

DEMONSTRATE COMPLIANCE.

54. REFER TO APPROVED LOW OBSERVABLE HANGAR MOCK UP FOR

BUILDING MATERIAL AND QUALITY OF CONSTRUCTION. PROVIDE

SHOP DRAWINGS TO MATCH APPROVED MOCK UP MATERIAL AND

CONSTRUCTION DETAILS.

26. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF

ALL PENETRATIONS IN THE STRUCTURE FOR THE PROPER

INSTALLATION OF THE WORK. REFER TO STRUCTURAL DRAWINGS

FOR SECONDARY FRAMING AND/OR REINFORCING REQUIRED AT

PENETRATIONS IN STEEL, CONCRETE OR MASONRY.

27. THE CONTRACTOR MUST PROVIDE ACCESS DOORS OR PANELS AS

REQUIRED FOR SERVICING OF PIPING, DUCTWORK, CABLE TRAYS,

FIRE DAMPERS AND SIMILAR APPLICATIONS. ALL PROPOSED

ACCESS DOOR LOCATIONS TO BE SUBMITTED FOR APPROVAL

PRIOR TO INSTALLATION.

28. PROVIDE ALL HVAC, PLUMBING, GAS OR ELECTRIC SERVICE

CONNECTIONS TO CASEWORK, FIXTURES, SIGNAGE, OR

EQUIPMENT INDICATED (WHETHER UNITS ARE INSTALLED BY

CONTRACTOR OR BY OTHERS).

29. BRACE PARTITIONS, SUSPENDED CEILINGS, SOFFITS, SUSPENDED

ITEMS, ETC. ONLY TO STRUCTURAL ELEMENTS ABOVE. DO NOT

ANCHOR TO ROOF DECK, PLUMBING / SPRINKLER PIPES,

DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR ELEMENTS. REFER

TO SECTION 13 48 73 SEISMIC CONTROL FOR MECHANICAL

EQUIPMENT FOR MORE INFORMATION.

30. EXTEND ALL FLOORING AND WALL-BASE COMPLETELY INTO

RECESSES, UNDER OPEN COUNTERTOPS, AND BEHIND ALL

EQUIPMENT.

31. ALL MATERIALS USED FOR CONSTRUCTION MUST BE NEW AND

UNDAMAGED. THE CONTRACTOR MUST SUBMIT SHOP DRAWINGS

AS REQUIRED IN THE SPECIFICATIONS.

32. THE CONTRACTOR MUST BECOME FULLY ACQUAINTED WITH

CONDITIONS RELATED TO THE WORK. ANY DISCREPANCIES

BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS MUST BE

REPORTED TO THE DESIGN PROFESSIONALS FOR RESOLUTION

PRIOR TO PROCEEDING WITH THE WORK.

33. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED

FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED

AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE

CONTRACTOR.

34. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR

CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND

REPORT TO THE CONTRACTOR IN WRITING ANY CONDITIONS

DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THE

INSTALLERS WORK. DO NOT PROCEED UNTIL UNSATISFACTORY

CONDITIONS ARE CORRECTED. INSTALLATION MUST CONSTITUTE

ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.

35. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS MUST MEAN THAT

THE CONDITIONS OR DIMENSION IS THE SAME OR

REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.

36. CONTROL JOINTS (CJ) MUST BE INSTALLED AT ALL PARTITIONS. CJ

AT GYPSUM PARTITIONS MUST BE MAXIMUM 30'-0" O.C., CJ AT

CONCRETE MASONRY UNIT PARTITIONS MUST BE MAXIMUM 20'-0"

O.C., UNLESS OTHERWISE NOTED ON DRAWINGS. REFER TO

ELEVATION DRAWINGS FOR EXTERIOR CONTROL JOINT

LOCATIONS. REVIEW CJ LOCATIONS WITH COR PRIOR TO

INSTALLATION.

37. NON-BEARING PARTITIONS MUST BE ISOLATED FROM THE

BUILDING STRUCTURE TO PREVENT TRANSFER OF BUILDING

LOADS FROM THE STRUCTURE TO THE PARTITIONS.

38. NOT USED.

39. NOT USED.

40. NOT USED.

41. WHERE EXISTING FINISHED SURFACES ARE CUT SO THAT A

SMOOTH TRANSITION WITH NEW WORK IS NOT POSSIBLE,

TERMINATE EXISTING SURFACE ALONG A STRAIGHT LINE AT A

NATURAL LINE OF DIVISION AND MAKE RECOMMENDATION TO

COR.

42. PROTECT EXISTING WORK TO REMAIN. PERFORM CUTTING TO

ACCOMPLISH REMOVALS NEATLY AND AS SPECIFIED FOR CUTTING

NEW WORK. REPAIR ADJACENT CONSTRUCTION AND FINISH

DAMAGED DURING REMOVAL WORK. PATCH AS SPECIFIED FOR

PATCHING NEW WORK.

43. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXTENT,

NATURE, AND SCOPE OF WORK DESCRIBED IN THE CONTRACT

DOCUMENTS AND COORDINATING WITH THE COR THE

INTERFACING OF THE EXISTING BUILDING AND THE WORK SHOWN

AND DESCRIBED IN THESE CONTRACT DOCUMENTS.

44. ALL "EXISTING" INFORMATION ON THE CONTRACT DOCUMENTS

HAS BEEN OBTAINED FROM A PREVIOUS SET OF DRAWINGS, OR

FROM FIELD INVESTIGATION AND SUCH "EXISTING" INFORMATION

MUST BE FIELD VERIFIED BY ALL CONTRACTORS.

45. NOT USED.

46. NOT USED.

47. BASIS OF DESIGN PRODUCTS ARE NOT INTENDED TO LIMIT THE

SELECTION FROM OTHER MANUFACTURERS. HOWEVER PRODUCT

QUALITY MUST MATCH TO BASIS

OF DESIGN PRODUCT AND SPECIFICATION REQUIREMENTS.

48. PROVIDE SEALANT AT ALL JOINTS ALONG ROOF, WALL SYSTEMS,

PENETRATIONS, FLASHINGS, AND OPENINGS.

49. ALL EXTERIOR WALL MOUNTED ELEMENTS ON CMU SHALL BE

INSTALLED OVER SMOOTH FACE CMU. CONTRACTOR SHALL

COORDINATE ALL EXTERIOR WALL MOUNTED ELEMENTS BEFORE

EXTERIOR WALL INSTALLATION. PROVIDE SMOOTH FACE CMU AS

REQUIRED WHERE WALL MOUNTED ELEMENTS ARE MOUNTED.

1. ALL WORK MUST COMPLY WITH ALL APPLICABLE CODES AND

STANDARDS AS LISTED OR REFERENCED ON LIFE SAFETY PLAN

AND LIFE SAFETY CRITERIA.

2. THE CONTRACTOR MUST INCLUDE ALL WORK REQUIRED TO

COMPLY WITH ALL APPLICABLE CODES AND STANDARDS AS

LISTED OR REFERENCED ON LIFE SAFETY PLAN AND LIFE SAFETY

CRITERIA.

3. DIMENSIONS MUST GOVERN. DETAILS MUST GOVERN OVER

PLANS AND ELEVATIONS. LARGE SCALE DETAILS OR PLANS MUST

GOVERN OVER SMALL SCALE DETAILS OR PLANS. DO NOT SCALE

DRAWINGS.

4. THE GENERAL CONTRACTOR MUST PROVIDE AND INSTALL ALL

EXIT SIGNS, EMERGENCY LIGHTING SYSTEMS, ALARM SYSTEMS

AND AUTOMATIC SPRINKLER SYSTEMS AS REQUIRED BY

APPLICABLE CODES AND STANDARDS OR AS REQUIRED BY THE

AUTHORITY HAVING JURISDICTION.

5. ALL FLOORS MUST BE INSPECTED FOR DAMAGE, WARPING OR

OTHER NOTICEABLE DEVIATIONS AND PATCHED AND LEVELED

PRIOR TO COVERING WITH FLOOR FINISHES, INSTALLATION OF

FLOOR GRATING SYSTEM, OR ERECTION AND INSTALLATION OF

COLD-FORMED FRAMING. TEST FLOOR SLAB MOISTURE CONTENT

BEFORE FLOOR FINISH INSTALLATION AS REQUIRED PER

SPECIFICATION.

6. THE GENERAL CONTRACTOR MUST BE RESPONSIBLE FOR

PROVIDING ALL MANUFACTURER'S RECOMMENDED MAINTENANCE

PROCEDURES AND SCHEDULES.

7. NOT USED.

8. ALL CONSTRUCTION MUST MEET OR EXCEED SPECIFIED

STANDARDS. DETAILS ARE PROVIDED TO INDICATE MINIMUM

QUALITY AND TO GIVE STANDARDS OF CONSTRUCTION. IF A

CONDITION IS NOT SPECIFICALLY DETAILED, SUBMIT A SIMILAR

DETAIL FOR GUIDANCE AND APPROVAL.

9. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS,

SECTIONS OR ELEVATIONS.

10. PROVIDE PRESERVATIVE-TREATED WOOD AT ALL LOCATIONS

WHERE WOOD IS IN DIRECT CONTACT WITH CONCRETE, MASONRY

AND GROUND.

11. PROVIDE 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING AT

ALL ELECTRICAL, PHONE, AND SECURITY SYSTEM PANELS.

ENSURE ALL LABELS ARE CLEAR OF PAINT AND NOT COVERED.

12. PROVIDE FIRE-RESISTANT TREATED WOOD BLOCKING OR 20

GAUGE MINIMUM METAL BACKING FOR SECURE ANCHORAGE OF

ALL SHELVES, RUNNING TRIM, RAILINGS, SUSPENDED ITEMS,

DOOR-STOPS, GRAB-BARS, AND OTHER SIMILAR WOODWORK,

HARDWARE, SPECIALTIES, ACCESSORIES, FIXTURES, OR

EQUIPMENT.

13. PROVIDE CEMENTITIOUS BACKER UNIT AT ALL AREAS WHERE A

TILE SURFACE IS TO BE INSTALLED ON METAL STUD WALLS.

14. PROVIDE WATER-RESISTANT GYPSUM BOARD AT ALL WET OR

UNCONDITIONED AREAS INCLUDING, BUT NOT LIMITED TO,

PARTITIONS BEHIND SINKS. CONTRACTOR TO ENSURE THAT FIRE

RATING IS MAINTAINED.

15. PAINT, STAIN, OR COAT ALL EXPOSED SURFACES OF

CONSTRUCTION UNLESS NOTED OTHERWISE OR IF SURFACES

ARE PRE-FINISHED.

16. ALL OPENING DIMENSIONS ARE NOMINAL. THE CONTRACTOR

MUST FIELD MEASURE ALL OPENINGS AND COORDINATE WITH THE

APPROPRIATE SUPPLIER FOR ALL DOORS AND WINDOWS.

17. ALL CONDUITS, PLUMBING, PIPING, DUCTWORK, AND OTHER

EQUIPMENT EXPOSED TO VIEW MUST BE LOCATED PARALLEL OR

PERPENDICULAR TO THE STRUCTURAL FRAMING SYSTEM.

18. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR

MATERIALS, WHERE REQUIRED.

19. FIBERGLASS REINFORCED PANELS TO BE INSTALLED UP TO 6'-0"

ABOVE WALL BASE AT ALL MOP SINK LOCATIONS. EXTENT OF

PANELS VARIES BY LOCATION. REFER TO FINISH SCHEDULE, WALL

FINISH DRAWINGS, AND INTERIOR ELEVATIONS.

20. ARCHITECTURAL DETAILS ARE APPLICABLE WHERE INDICATED BY

SECTION CUT, BY NOTE, OR BY DETAIL TITLE. INCORPORATE

SIMILAR DETAILS AT SIMILAR CONDITIONS UNLESS NOTED

OTHERWISE. THE CONTRACTOR MAY REQUEST A CLARIFICATION

IF REQUIRED, OTHERWISE THE MORE STRINGENT REQUIREMENTS

MUST CONTROL.

21. PROVIDE FIRE-STOPPING SYSTEMS AT TOP OF AND AT ALL

PENETRATIONS THROUGH FIRE-RATED WALL ASSEMBLIES AND

FIRE RATED FLOOR ASSEMBLIES.

22. SEAL ALL EXTERIOR BUILDING JOINTS AT BOTH THE EXTERIOR

AND INTERIOR SURFACES AGAINST MOISTURE AND AIR

INFILTRATION.

23. SEAL AROUND ALL DOOR AND WINDOW FRAMES, COUNTERTOPS,

WALL-MOUNTED FIXTURES AND EQUIPMENT TO ADJACENT WALL

SURFACES.

24. THE CONTRACTOR MUST REVIEW THE DIMENSIONS OF ALL

EQUIPMENT IN THE PROJECT REGARDLESS OF THE SOURCE AND

COORDINATE ACCESS TO THE SPACE AND VERIFY CLEAR FLOOR

SPACE IS PROVIDED AS REQUIRED TO ENSURE EASE OF

INSTALLATION.

25. ALL WORK MUST BE OF GOOD QUALITY, FREE FROM DEFECTS,

AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE

CONTRACT DOCUMENTS.

NOTE: PROVIDE BLOCKING FOR ALL TOILET ACCESSORIES AS NEEDED.

(7

M

IN

M

IR

R O

R

F U

L

E N

G T

H

(1

F O

L D

IN

G

S H

O W

R

S

A

T

M O

P A

N D

B R

O O

M

H

L D

E R

R O

B

O

K

R O

O

K

(3

B A

B Y

C H

A N

G

IN

G

T

A T

IO

N

S A

N

IT

A R

Y N

A P

K

D

IS

P

O S

A L

T O

IL

E

T P

A P

P

E N

S E

R

S A

N

IT

A R

Y N

A P

K

P

E N

S E

R

E L

E C

T R

IC

H

A N

Y E

R

(3

(3

(3

M A

X

H E

IG

H

T M

O U

N T

IN

G

(A

A

Q U

IR

N G

E

(3

D R

IN

K

G

F

U

N T

A

IN

F

IX

T U

R E

/E Q

U

IP

M E

N T

T Y

P E

ADA

COMPLIANT

INDICATOR

LEGEND

FINISH FLOOR

LEVEL (FFL) 40

/2

(1

A N

S I .1

G

L E

R O

L L

(1

A N

S I .1

U

B L E

R O

L L

(1

A D

A /A

B A

M

IR

R O

R

(3

M A

X

M

IR

R O

R A

B O

V

V

A T

O R

Y

(4

M A

X

T

F

L E

C T

IV

U R

F A

C E

T O

IL

E

T S

T A

O

R

6" MIN CLEAR

P A

P E

R T

O W

P

E N

S E

R

S O

A P

D

IS

P E

N S

E R

T O

IL

E

T S

E A

T C

O V

P

E N

S E

R

(3

(3

(1

P A

P E

R T

O W

E L

D

IS

P E

N S

W

IT

H

W A

S T

E D

IS

P

O S

A L

" 40

" 60

9" M

IN

T

Y P

M

IN

F O

R C

H

IL

D R

E N

'S U

S E

F

IR

E E

X T

IN

G

U S

H E

R

T O

IL

E

T S

E A

T C

O V

P

E N

S E

R

M A

X

APRON

FRONT VIEW (DOUBLE)

FACE OF

ADJACENT WALL

SIDE VIEW

EDGE OF WALL

BEYOND

WIDTH OF ALCOVE

48" MIN

T O

S P

O U

T

M A

X

TO SPOUT

24" MIN CLR

O F

L E

A D

IN

G

E D

G E

T O

B O

T T

O M

CLR FLOOR SPACE

30" MIN

DEPTH OF

24" MAX

ALCOVE

M A

X

9" M

IN

6" MIN

8" MIN

T O

B O

T T

O M

M

IN

F O

R C

LR

15" MIN. 5" MAX.

11" MIN

T O

S P

O U

T

BOTTLE

FILLER

CLEAR

FLOOR

SPACE

48" MIN.

19" MAX.

M

IN

KNEE

CLEARANCE

8" MIN.

25" MAX.

17" MIN.

11" MIN.

M A

X

B .O

. M

IR

R O

R

M A

X

M

IN

9" M

IN

6" MAX.

TOE

CLEARANCE

4" MAX

CONTROL WALL

SEAT WALL

B A

C K

W A

L L

4" MAX

MAX

1' - 3"

M A

X

M A

X

CL

CONTROL WALL

ELEVATION

LOCATION

OF

CONTROLS

AND HAND

SHOWER

1/

2"

MAX

1 1/2"

14"-15"

3" MAX

OF SEAT

PLAN VIEW SIDE VIEW

3' - 0" 30" MIN

3'

M

IN

6" M

A X

4" M

IN

M

IN

M A

X

1' -0

M

IN

3'

C

LE

A R

3' - 0" CLEAR 3' - 0" CLEAR

GRAB BAR

SOAP DISH

CONTROL AREA

(TRANSFER-TYPE SHOWER)

ROBE HOOK

SHOWER

CURTAIN & ROD

FOLDING

SHOWER SEAT

TOWEL PIN

SHOWER

CURTAIN & ROD

CLEAR

FLOOR

SPACE

36" IF IN ALCOVE

GREATER THAN 24" DEEP

30" TYP

T Y

P

TAPERED

ELONGATED RIM

13 1/2" MIN

A B

A

A D

A

M

A X

A B

A

A D

A

M A

X

NOTE:

FLUSH VALVE MUST BE LOCATED

ON WIDE SIDE OF STALLS

12" MIN

36" MIN

TOILET

PAPER

42" MIN

A

7.

M

IN

IC

C

/A N

S I

12" MAX

TRANSFER

SIDE

39" - 41"

M

IN

7"- 9"

24" MIN

M

IN

A D

A /A

B A

D O

U B

LE

R

O

LL

(1 8"

M

G

LE

R

O

LL

1/

2" C

LE

A

R M

IN

INTERNATIONAL PLUMBING

CODE (IPC) GOVERNS

42" MIN

M

IN

42" MIN 12" MAX

54" MIN

56" MIN WALL WC

60" IPC 2000

59" MIN FLOOR WC

(ICC / ANSI A117.1 & ABA / ADA)

3'

M

IN

4" M

A X

6" MIN*

4" MAX

32" MIN

6" M

IN

ALTERNATE DOOR

LOCATION

TOE CLEARANCE 9"

HIGH AFF CLR *

32" MIN

36" MIN

42" ICC / ANSI A117.1

GOVERNS - CLEAR FROM

OUTSIDE FACE OF

ADJACENT STALL

42" MIN

56" MIN WALL WC

60" IPC 2000

59" MIN FLOOR WC

(ICC / ANSI 117.1 & ABA / ADA)

M

IN

42" MIN

12" MAX

M

IN

54" MIN

1. WHERE "*" IS INDICATED - TOE CLEARANCE AT THE FRONT OF THE PARTITION IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 62" DEEP WITH A WALL-HUNG WATER CLOSET OR 65" DEEP WITH A FLOOR-MOUNTED WATER CLOSET. TOE CLEARANCE AT THE SIDE IS NOT REQUIRED IN A COMPARTMENT GREATER THAN 66" WIDE (ICC / ANSI A117.1 / ABA / ADA). TOE CLEARANCE IS EXCLUSIVE OF PARTITION SUPPORT MEMBERS.

STANDARD STALL STANDARD STALL

LATCH SIDE APPROACH

ONLY, ALL OTHER

APPROACHES TO BE 48"

(ABA / ADA) INTERNATIONAL

PLUMBING CODE (IPC)

GOVERNS

M

IN

M

IN

1'

M

IN

M

IN

1'

AMBULATORY STALL

M A

X

M

IN

M

IN

M

IN

32" MIN

17" - 19"

35" - 37"

M

IN

CLEAR

FLOOR

SPACE

60" MIN

42" MIN

M

IN

A B

A

A D

A

G O

V E

R N

S

M

IN

IC

C

A

N S

I A

II7

.1

16" - 18"

CLEAR FLOOR SPACE @ WATER

CLOSETS NOT IN STALLS

FINISHED WALL

4" MIN. 3' - 4" 1' - 0"

1' - 6" MIN.

VERIFY THERE IS A MINIMUM 18" CLEAR

FROM DOOR STRIKE TO INTERSECTING

WALL FOR ACCESSIBLE COMPLIANCE.

NOTIFY CONTRACT OFFICER FOR NON-

COMPLIANCE BEFORE SETTING DOOR

FRAME AND WALL LOCATIONS

TYPICAL DOOR JAMB

LOCATION UNLESS

DIMENSIONED OTHERWISE

ALL ROOM SIGNS, LIGHT

SWITCHES AND

THERMOSTATS TO BE

LOCATED WITHIN THIS SPACE

NOTE:

REVIEW GUIDELINES FOR OTHER DOOR

APPROACH CLEARANCE REQUIREMENTS

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

AG003

A C

C E

S S

IB

IL

IT

Y

I N

F O

R M

A T

IO

N

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

(NOTE: NOT EVERY ITEM OR CONDITION SHOWN ON THIS SHEET MAY OCCUR IN THIS PROJECT)

NTSSCALE:A1

STANDARD ACCESSIBLE MOUNTING HEIGHTS

NTSSCALE:L1

ELECTRIC WATER COOLER

NTSSCALE:L6

LAVATORIES

NTSSCALE:L10

SHOWER STALLS

NTSSCALE:L16

ACCESSIBLE SHOWER STALL

NTSSCALE:H1

URINALS

NTSSCALE:E1

GRAB BARS

NTSSCALE:E10

STANDARD ACCESSIBLE STALLS

NTSSCALE:E7

WATER CLOSETS

NTSSCALE:H6

DOOR CLEARANCES

C

D

E

F

54321 6 7 8 9 11

HANGAR BAY 1

CLEARANCE

REQUIREMENTS FOR B-2A

H1

A-011

A1

A-011

EQ. EQ.

200' - 8" CLEAR DOOR OPENING

CENTERLINE OF HANGAR BAY & AIRCRAFT

T O

C O

LU

M

N F

A C

E

T O

D O

O R

F A

C E

0"

TO FACE OF STEEL

15' - 4" 172' - 0"

TO FACE OF STEEL

15' - 4"

"15' - 0"

15' - 0" 15' - 0"

15' - 0"

" 15

"15

" 15' - 0"

15' - 0"

ALL REQUIRED CLEAR DIMENSIONS ARE MINIMUM.

HANGAR BAY 2 NOT SHOWN. HANGAR BAY 1 AND 2 MUST BE

CONSTRUCTED THE SAME SIZE WITH THE SAME CLEARANCE

REQUIREMENTS.

GENERAL SHEET NOTES

1.

2. US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-010

A

IR

C R

A F

T C

L E

A R

A N

C E

R E

Q U

IR

E

M E

N T

S

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

SCALE: 3/32" = 1'-0"A1

AIRCRAFT CLEARANCE REQUIREMENTS

0 8' 16' 24'

PLAN

NORTH

KEY PLAN

CA B

ALL REQUIRED CLEAR DIMENSIONS ARE MINIMUM.

HANGAR BAY 2 NOT SHOWN. HANGAR BAY 1 AND 2 MUST BE

CONSTRUCTED THE SAME SIZE WITH THE SAME CLEARANCE

REQUIREMENTS.

GENERAL SHEET NOTES

1.

2.

GROUND FLOOR

100' - 0"

T.O. MASONRY

110' - 0"

DOOR CLEAR HEIGHT

126' - 8"

BOTTOM OF TP

119' - 0"

A B C D E F

ROOF PEAK

147' - 1 1/2"

A1

A-011

FALL ARREST SYSTEM RAILING

TO DOOR FACE

12' - 10" 69' - 0"

TO COLUMN FACE

15' - 0"

TOP OF TP

127' - 0"

DRAFT CURTAIN

ROOF EAVE

137' - 4"

HANGAR BAY 1

GROUND FLOOR

100' - 0"

T.O. MASONRY

110' - 0"

BOTTOM OF TP

119' - 0"

5 4 3 2 1678

H1

A-011

HANGAR BAY 1

FALL ARREST SYSTEM RAILING

DRAFT CURTAIN

TO FACE OF STEEL

15' - 4" 172' - 0"

TO FACE OF STEEL

15' - 4"

TOP OF TP

127' - 0"

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-011

A

IR

C R

A F

T C

L E

A R

A N

C E

R E

Q U

IR

E

M E

N T

S S

E C

T

IO

N S

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

SCALE: 3/32" = 1'-0"

H1

AIRCRAFT CLEARANCE REQUIREMENTS SECTION

SCALE: 3/32" = 1'-0"

A1

AIRCRAFT CLEARANCE REQUIREMENTS SECTION

0 8' 16' 24'

C

D

E

F

18 19 20 21 221716151454321 6 7 8 9 11 12

ZONE 1

(INSPECTION ONLY)

ZONE 2

(INSPECTION ONLY)

ZONE 4

ZONE 9

(INSPECTION ONLY)

F

A

A A

A

F

F

FF

B C D B C D

B C D B C D

B C DB C DC C

F

G1

A-022

G1

A-022

A3

A-023

A3

A-023

ZONE 3

(INSPECTION ONLY)

F

ZONE 10

(INSPECTION ONLY)

A

A

B C D

B C D

B D

B C DB C D

H3

A-023

H3

A-023

ZONE 5

(INSPECTION ONLY)

ZONE 6

(INSPECTION ONLY)

ZONE 8

(INSPECTION ONLY)

ZONE 7

(INSPECTION ONLY)

G

G

A

A

F

F

F

F

F

F

10 13

GG

G G

A1

A-022

A1

A-022

ZONE 12

(INSPECTION ONLY)

A

A

A

A13

A-521

A13

A-521

1. SEE SPECIFICATION 07 05 23 FOR PRESSURE

TESTING AND AIR BARRIER SYSTEM FOR AIR

TIGHTNESS.

2. REFERENCE WALL SECTIONS AND DETAILS FOR

CONTINUOUS AIR BARRIER.

3. STANDING SEAM METAL ROOF SYSTEM AIR BARRIER

MUST BE VAPOR BARRIER OVER ROOF THERMAL

BOARD. ROOF INSULATION AND ROOF BOARD MUST

BE INSTALLED IN STAGGERED PATTERN AND ALL

JOINTS MUST BE SEALED WITH TAPE.

4. AIR BARRIER LOCATION.

5. AIR BARRIER AREA MUST BE FIELD VERIFIED BY

CONTRACTOR.

6. SEE SPECIFICATION 07 27 10.00 10 FOR AIR BARRIER

SYSTEM AND REQUIREMENTS.

7. SEAL ALL PENETRATIONS AT EACH ZONE BOUNDARY

FOR AIR TIGHTNESS.

8. ALL EXPOSED CMU MUST BE PAINTED. PAINTED CMU

WILL ACT AS VAPOR RETARDER. ALL PENETRATIONS

MUST BE SEALED.

9. ALL GYPSUM BOARD FURRING ON EXTERIOR WALL

MUST EXTEND TO BOTTOM OF ROOF DECK. ALL

GYPSUM BOARD MUST BE PAINTED. ALL PAINTED

GYPSUM BOARD WILL ACT AS VAPOR RETARDER.

ALL PENETRATIONS MUST BE SEALED.

10. PROVIDE WEATHER SEAL AT ALL DOORS AT AIR

BARRIER ZONE BOUNDARY

11. PROVIDE ELASTOMERIC PUTTY OVER OUTLETS ON

ZONE BOUNDARY WALLS.

12. GENERAL CONTRACTOR MUST INSPECT AIR

BARRIER INSTALLATION DAILY TO ENSURE AIR

BARRIER TIGHTNESS

GENERAL SHEET NOTESLEGEND

CAST IN PLACE CONCRETE FLOOR

FLUID APPLIED VAPOR BARRIER OVER CMU

INSULATED METAL WALL PANEL

SPRAY FOAM INSULATION AT TOP OF WALL

VAPOR BARRIER OVER ROOF THERMAL BOARD

3-COAT MIN. PAINTED CMU W/ BLOCK FILLER PRIMER

3-COAT MIN. PAINTED GYPSUM WALL BOARD

METAL DECKING

- METAL DECKING MUST OVERLAP AT LEAST 6

INCHES WITH TWO BEADS OF CONTINUOUS

SEALANT

- USE SELF TAPPING SCREW WITH NEOPRENE

WASHERS

- ALL DECK PENETRATION MUST SEAL WITH

INTUMESCENT FOAM SEALER

A

THE FOLLOWING MATERIALS REQUIRE AIR PERMEABILITY

NOT TO EXCEED 0.004 CFM/SQFT @ 75PA TESTED IN

ACCORDANCE WITH ASTM E2178:

B

C

D

E

F

G

H

AIR BARRIER SUMMARY

ZONE 1 (INSPECTION ONLY)

FLOOR AREA = 24,244 SF

WALL AREA = 30,739 SF

ROOF AREA = 24,583 SF

ZONE 2 (INSPECTION ONLY)

FLOOR AREA = 962 SF

WALL AREA = 2,179 SF

ROOF AREA = 962 SF

ALLOWABLE LEAKAGE RATE (ALR): 0.40 CFM/SF

ALR

9,697 CFM

12,295 CFM

9,833 CFM

ALR

385 CFM

872 CFM

385 CFM

TOTAL AREA = 79,566 SF 31,825 CFM

TOTAL AREA = 4,103 SF 1,642 CFM

ZONE 3 (INSPECTION ONLY)

FLOOR AREA = 522 SF

WALL AREA = 1,426 SF

ROOF AREA = 522 SF

ALR

209 CFM

570 CFM

209 CFM

TOTAL AREA = 2,470 SF 988 CFM

ZONE 4

FLOOR AREA = 5,376 SF

WALL AREA = 8,562 SF

ROOF AREA = 5,376 SF

ALR

2,150 CFM

3,425 CFM

2,150 CFM

TOTAL AREA = 19,314 SF 7,725 CFM

ZONE 5 (INSPECTION ONLY)

FLOOR AREA = 264 SF

WALL AREA = 1,015 SF

ROOF AREA = 264 SF

ALR

105 CFM

406 CFM

105 CFM

TOTAL AREA = 1,543 SF 616 CFM

ZONE 7 (INSPECTION ONLY)

FLOOR AREA = 392 SF

WALL AREA = 1278 SF

ROOF AREA = 392 SF

ALR

157 CFM

511 CFM

157 CFM

TOTAL AREA = 2,062 SF 825 CFM

ZONE 6 (INSPECTION ONLY)

FLOOR AREA = 900 SF

WALL AREA = 1,885 SF

ROOF AREA = 900 SF

ALR

360 CFM

754 CFM

360 CFM

TOTAL AREA = 3,685 SF 1,474 CFM

ZONE 8 (INSPECTION ONLY)

FLOOR AREA = 796 SF

WALL AREA = 1818 SF

ROOF AREA = 796 SF

ZONE 9 (INSPECTION ONLY)

FLOOR AREA = 983 SF

WALL AREA = 2,149 SF

ROOF AREA = 983 SF

ALR

318 CFM

727 CFM

318 CFM

ALR

393 CFM

860 CFM

393 CFM

TOTAL AREA = 3,410 SF 1,363 CFM

TOTAL AREA = 4,115 SF 1,646 CFM

ZONE 10 (INSPECTION ONLY)

FLOOR AREA = 24,244 SF

WALL AREA = 30,739 SF

ROOF AREA = 24,583 SF

ALR

9,697 CFM

12,295 CFM

9,833 CFM

TOTAL AREA = 79,566 SF 31,825 CFM

ZONE 11 (INSPECTION ONLY)

FLOOR AREA = 8,246 SF

WALL AREA = 1,459 SF

ROOF AREA = 510 SF

ALR

3,298 CFM

584 CFM

204 CFM

TOTAL AREA = 2,479 SF 992 CFM

ZONE 12 (INSPECTION ONLY)

FLOOR AREA = 415 SF

WALL AREA = 1,264 SF

ROOF AREA = 415 SF

ALR

166 CFM

506 CFM

166 CFM

TOTAL AREA = 2,094 SF 838 CFM

BUILDING AIR BARRIER SYSTEM:

ROOF:

EXTERIOR WALL:

INTERIOR WALL:

FLOOR:

• PEEL-AND-STICK VAPOR BARRIER OVER 1/2 INCH

THICK GYPSUM THERMAL BOARD.

• MEDIUM DENSITY CLOSED CELL SPRAY

POLYURETHANE FOAM (SPF) INSULATION APPLIED AT

EXTERIOR WALL AND ROOF TRANSITION.

• FLUIID APPLIED MEMBRANE VAPOR/AIR BARRIER

OVER CMU

• PREFABRICATED INSULATED METAL WALL PANEL

SYSTEM ITSELF IS AN AIR BARRIER

• PEEL-AND-STICK VAPOR/AIR BARRIER APPLIED OVER

MATERIAL TRANSITION AND GEOMETRY

• 3 COAT PAINTED CMU FROM FLOOR TO DECK ABOVE

• 3 COAT PAINTED GYPSUM WALL BOARD FROM

FLOOR TO DECK ABOVE

• ELASTOMERIC SPRAY APPLIED ON TOP OF THE

WALL, ROOF/FLOOR DECK CONJUNCTION, AND WALL

PENETRATION

• CONCRETE FLOOR

• VAPOR BARRIER APPLIED ON UNDERSIDE OF

GROUND FLOOR

FOUNDATION WALL:

• DAMP PROOFING OVER CONCRETE STEM WALL

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-020

O V

E R

A L L G

R O

U N

D F

L O

O R

A

IR

B A

R R

IE

R

P L A

N

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

SCALE: 3/64" = 1'-0"C1

OVERALL GROUND FLOOR AIR BARRIER PLAN

0 16' 32' 48'

PLAN

NORTH

C

D

E

F

18 19 20 21 221716151454321 6 7 8 9 11 12

G1

A-022

G1

A-022

A3

A-023

A3

A-023

ZONE 1

(INSPECTION ONLY) ZONE 11

(INSPECTION ONLY)

G

C D C D

C D C D

C DC DC C

ZONE 10

(INSPECTION ONLY)

C D

C D

H3

A-023

H3

A-023

H

G

G G

10 13

A A

A

A

ZONE 2 LID ZONE 9 LIDZONE 3 LID

A1

A-022

A1

A-022

D D

G13

A-521

G13

A-521

AIR BARRIER SUMMARY

ZONE 1 (INSPECTION ONLY)

FLOOR AREA = 24,244 SF

WALL AREA = 30,739 SF

ROOF AREA = 24,583 SF

ALLOWABLE LEAKAGE RATE (ALR): 0.40 CFM/SF

ALR

9,697 CFM

12,295 CFM

9,833 CFM

TOTAL AREA = 79,566 SF 31,825 CFM

ZONE 10 (INSPECTION ONLY)

FLOOR AREA = 24,244 SF

WALL AREA = 30,739 SF

ROOF AREA = 24,583 SF

ALR

9,697 CFM

12,295 CFM

9,833 CFM

TOTAL AREA = 79,566 SF 31,825 CFM

ZONE 11 (INSPECTION ONLY)

FLOOR AREA = 8,521 SF

WALL AREA = 10,068 SF

ROOF AREA = 8,640 SF

ALR

3,408 CFM

4,027 CFM

3,456 CFM

TOTAL AREA = 27,229 SF 10,891 CFM

1. SEE A-020 FOR BUILDING AIR BARRIER SYSTEM NOTES,

AIR BARRIER LEGEND, AND ADDITIONAL GENERAL NOTES.

GENERAL SHEET NOTES

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-021

O V

E R

A L L S

E C

O N

D F

L O

O R

A

IR

B A

R R

IE

R

P L A

N

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

SCALE: 3/64" = 1'-0"

C1

OVERALL AIR BARRIER PLAN AT 28'-0"

0 16' 32' 48'

PLAN

NORTH

GROUND FLOOR

100' - 0"

B.O. PLATFORM

115' - 6"

T.O. MASONRY

110' - 0"

18 19 20 21 221716151454321 6 7 8 9 11 12

ZONE 1

(INSPECTION ONLY)

ZONE 10

(INSPECTION ONLY)

ZONE 4

ZONE 2

(INSPECTION ONLY)

ZONE 9

(INSPECTION ONLY)

A A

A A

A

B

C D

B

C D

E

F F F F

ZONE 3

(INSPECTION ONLY)

A

F

TYP. AT ALL ROOFS

A A

A

TOP OF TP

127' - 0"

C13

A-573

C13

A-573

K11

A-502

K11

A-502

A1

A-510

A1

A-510

F1

A-503

F1

A-503

OPP

OPP F1

A-503

F1

A-503

ZONE 5

(INSPECTION ONLY)

ZONE 6

(INSPECTION ONLY)

A A

G

G1

A-551

A6

A-503

A11

A-502

A11

A-502

K11

A-502

A6

A-503

H

G1

A-551

G G

F1

A-503

F1

A-503

K6

A-503

ZONE 11

(INSPECTION ONLY)

10 13

ZONE 12

(INSPECTION ONLY)

A

OPP OPP

SIM SIM

1. SEE A-020 FOR BUILDING AIR BARRIER SYSTEM

NOTES, AIR BARRIER LEGEND, AND ADDITIONAL

GENERAL NOTES.

GENERAL SHEET NOTES

GROUND FLOOR

100' - 0"

T.O. MASONRY

110' - 0"

DOOR CLEAR HEIGHT

126' - 8"

A B C D E F

ROOF PEAK

147' - 1 1/2"

ROOF EAVE

137' - 4"

ZONE 1

(INSPECTION ONLY)

A

C D

B

C D

E

TYP. AT ALL ROOFS

A1

A-633

G1

A-573

A1

A-573

A1

A-510

SIM

G1

A-633

SIM

C

J1

A-510

A1

A-575

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-022

A

IR

B A

R R

IE

R

S E

C T

IO

N

S

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

SCALE: 3/64" = 1'-0"G1

AIR BARRIER BUILDING SECTION

0 16' 32' 48'

SCALE: 3/32" = 1'-0"A1

AIR BARRIER BUILDING SECTION

GROUND FLOOR

100' - 0"

B.O. PLATFORM

115' - 6"

T.O. MASONRY

110' - 0"

A B C D E F

ROOF PEAK

147' - 1 1/2"

TOP OF TP

127' - 0"

A

C

B

C

A

E TYP. AT ALL ROOFS

D

C D

B

D

A1

A-573

A1

A-510

G1

A-573

F11

A-502

H

A1

A-510

F

ZONE 4

ZONE 11

(INSPECTION ONLY)

A10

A-512 C12

A-574

ROOF EAVE

137' - 4"

A11

A-503

OPP

A1

A-503

SIM

GROUND FLOOR

100' - 0"

B.O. PLATFORM

115' - 6"

T.O. MASONRY

110' - 0"

A B C D E F

ROOF PEAK

147' - 1 1/2"

ZONE 3

(INSPECTION ONLY)

ZONE 4

ZONE 1

(INSPECTION ONLY)

A A A

B

C D

B

C D

F F

E

TYP. AT ALL ROOFS

A

A1

A-633

G1

A-573

A1

A-573

F1

A-503

F1

A-503

A1

A-510

F1

A-503

F1

A-503

K11

A-502

A11

A-502 A11

A-502

C16

A-503

F1

A-503

ZONE 7

F

A1

A-503 A1

A-512

ZONE 11

(INSPECTION ONLY)

H

ROOF EAVE

137' - 4"

OPP

1. SEE A-020 FOR BUILDING AIR BARRIER SYSTEM

NOTES, AIR BARRIER LEGEND, AND ADDITIONAL

GENERAL NOTES.

GENERAL SHEET NOTES

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-023

A

IR

B A

R R

IE

R

S E

C T

IO

N

S

T K

IM

J C

O B

L E

R

B C

H A

P M

A

NSCALE: 3/32" = 1'-0"H3

AIR BARRIER BUILDING SECTION

SCALE: 3/32" = 1'-0"A3

AIR BARRIER BUILDING SECTION

C

D

E

F

18 19 20 21 221716151454321 6 7 8 9 11 12

104 106

109101

120129

110114

CX

C

E/I

E/I E/I

E/I

E/I

E/I

E/IE/I

E/I

E/I

10 13

II

I

E/I

E/I

E/I

E/I

I

CX CX CC

I E/I

I E/I

C

EE

C/I

C/I

C/I

C/I

C

C

IDS AT FLOOR HATCH ABOVE

I

IDS AT FLOOR HATCH ABOVE

I

IDS AT ROOF HATCH ABOVE

I

DOOR REQUIREMENTS

WALL REQUIREMENTS

GENERAL SHEET NOTES

THIS SHEET IS BEST VIEWED IN COLOR

SEE TY-SERIES DRAWINGS FOR SECURE AREA

NOTES AND ADDITIONAL INFORMATION

SEE ELECTRICAL DRAWINGS FOR TYPICAL DUCT,

PIPE, AND CONDUIT GROUNDING FOR SECURE

SPACES

SEE MECHANICAL DRAWINGS FOR PENETRATIONS

THROUGH SECURE SPACES

PROVIDE IDS AT ROOF HATCH AND FLOOR HATCH

ABOVE SOAP ROOM

CONTRACTOR TO COORDINATE TY-SERIES

DRAWINGS, DOOR SCHEDULE, DOOR HARDWARE

SPEC, AND LIFE SAFETY DRAWINGS FOR ALL DOOR

HARDWARE AND SECURITY REQUIREMENTS

1.

2.

3.

4.

5.

6.

EXIT ONLY / IDS

X-10 LOCK / CARD READER / IDS

E/I

CX

50 STC 50 MININUM

IDSI

E EXIT ONLY

CARD READER

CARD READER / IDSC/I

C

STC 50 RATED WALL MINIMUM

LEGEND

SECURE AREA 1 - AMPLIFIED

SOUND / OPEN STORAGE

SECURE AREA 2 - NO OPEN STORAGE

SECURE AREA 3 - NO OPEN STORAGE

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-030

S E

C U

R

IT

Y P

L A

N

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

SCALE: 3/64" = 1'-0"

C1

OVERALL GROUND FLOOR SECURITY PLAN

PLAN

NORTH

KEY PLAN

CA B

ROOM SCHEDULE

NUMBER ROOM NAME

117 NURSING

118 MULTI-PURPOSE

119 OPEN OFFICE

120 CORRIDOR

121 COMM

122 SECURE VEST

123 SECURE OFFICE

124 STORAGE

125 NOT USED

126 MENS

127 MENS SHOWER

128 WASH BAY EQUIP

129 JAN

130 MECHANICAL PLATFORM

131 MECHANICAL PLATFORM

ROOM SCHEDULE

NUMBER ROOM NAME

101 HANGAR BAY 1

102 SOAP

103 PUMP/FOAM

104 ELEC

105 ENTRY VESTIBULE

106 MECH / AHU

107 BOILER

108 SOAP

109 HANGAR BAY 2

110 VEST 2

111 FLIGHT LINE VESTIBULE

112 STORAGE

113 CORRIDOR

114 VEST 1

115 WOMENS

116 WOMENS SHOWER

0 16' 32' 48'

A-201

E1

A-201

A1

A-201

K1

A-201

A10

A

B

C

D

E

F

2'

2'

18 19 20 21 221716151454321 6 7 8

2' - 8"29' - 4"29' - 4"29' - 4"30' - 0"29' - 4"29' - 4"29' - 4"26' - 4"

3"7' - 10"

21' - 2"7' - 10"

3' - 11"

22' - 8"29' - 4"29' - 4"29' - 4"30' - 0"29' - 4"29' - 4"29' - 4"2' - 8"

4'

507' - 4"

5' - 4"

200' - 8" CLEAR DOOR OPENING 95' - 4" 200' - 8" CLEAR DOOR OPENING 5' - 4"

H1

A-302

H1

A-302

H1

A-303

H1

A-303

11 12

AREA A AREA B AREA B AREA C

AREA A AREA B AREA B AREA C

L1

A-301

L1

A-301

G1

A-301

G1

A-301

A1

A-301

A1

A-301

A1

A-303

A1

A-303

A1

A-302

A1

A-302

1.8 1.8 1.6

1.61.6

9' - 8" 8' - 0"

1.13

1.13

104 106

118 119

109101

120129

110114

1.141.14

1.13

1.13

1.19

10 13

1.19 1.19

1.8 1.8

GENERAL SHEET NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND,

AND ABBREVIATIONS REFER TO SHEET AG001 & AG002.

REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS.

FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION

REFER TO PARTITION TYPES SHEET A-501 THRU A-503.

FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT

ILLUSTRATED, REFER TO LARGER SCALE DRAWINGS.

REFERENCE THE REFLECTED CEILING PLANS FOR CEILING

HEIGHTS.

ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU

WALL, AND FINISH FACE OF GYPSUM BOARD WALL, UNLESS

NOTED OTHERWISE.

THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0"

UNLESS NOTED OTHERWISE.

REFERENCE FURNITURE PLANS FOR LOCATIONS OF WALL

ACCESSORIES AND VISUAL DISPLAY EQUIPMENT. PROVIDE

BLOCKING AS REQUIRED TO SUPPORT ELEMENT ATTACHMENT.

TYPICAL DOOR JAMB LOCATION IS 0'-4" FROM ADJACENT

FINISHED WALL UNLESS DIMENSIONED OTHERWISE. REFER

SHEET AG003 FOR ACCESSIBLE DOOR CLEARANCES.

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-110

O V

E R

A L L G

R O

U N

D F

L O

O R

P L A

N

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

0 16' 32' 48'

SCALE: 3/64" = 1'-0"

B1

OVERALL GROUND FLOOR PLAN

ROOM SCHEDULE

NUMBER ROOM NAME

117 NURSING

118 MULTI-PURPOSE

119 OPEN OFFICE

120 CORRIDOR

121 COMM

122 SECURE VEST

123 SECURE OFFICE

124 STORAGE

125 NOT USED

126 MENS

127 MENS SHOWER

128 WASH BAY EQUIP

129 JAN

130 MECHANICAL PLATFORM

131 MECHANICAL PLATFORM

ROOM SCHEDULE

NUMBER ROOM NAME

101 HANGAR BAY 1

102 SOAP

103 PUMP/FOAM

104 ELEC

105 ENTRY VESTIBULE

106 MECH / AHU

107 BOILER

108 SOAP

109 HANGAR BAY 2

110 VEST 2

111 FLIGHT LINE VESTIBULE

112 STORAGE

113 CORRIDOR

114 VEST 1

115 WOMENS

116 WOMENS SHOWER

SHEET KEYNOTES

1.6 ROOF OVERHANG ABOVE

1.8 CANOPY ABOVE

1.13 DRAFT CURTAIN ABOVE

1.14 FALL PROTECTION RAILING ABOVE

1.19 MEP EQUIPMENT (RE: MECHANICAL

AND ELECTRICAL)

PLAN

NORTH

KEY PLAN

x

C

D

E

F

54321 6 7

AREA A AREA B

AREA A AREA B

29' - 4" 29' - 4" 29' - 4" 30' - 0" 29' - 4" 29' - 4"

1' - 4" 21' - 8"

2'

6'

HANGAR BAY 1

1'

3'

2'

1' - 4"

EQ 3' - 4" EQ

EQ. 3' - 4" EQ.

3' - 4" 5' - 8"

16' - 0"

3'

1.12

1.12 1.8

1.15

M1CB

101C

101B

101A

101G

101F

101E

A10

A-310

A10

A-312

1.6

1.11

99' - 6 1/4"

1.10

2' - 8"

2'

2' - 8" 2' - 8"

1/

/ 1

2"

99' - 6 1/4"

100' - 0"

1.13

99' - 6 3/4"

9' - 8"

9' - 8"

1.7

1.7

K1

A-630

99' - 6 1/4"

L1

A-521

G1

A-521

ABOVE

A1

A-314

2'

/2

A6

A-310

1.10

1.10

1.20 TYP

TYP

1.13

101D

A1

A-623

SIM

UP

A15

A-310

SIM

1.19 1.38

1.29

S

LO

P E

1.18

G13

A-521 A13

A-521

ABOVE

M1CA

M1CA

1.36

1.38

1.7

GENERAL SHEET NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND,

AND ABBREVIATIONS REFER TO SHEET AG001 & AG002.

REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS.

FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION

REFER TO PARTITION TYPES SHEET A-501 THRU A-503.

FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT

ILLUSTRATED, REFER TO LARGER SCALE DRAWINGS.

REFERENCE THE REFLECTED CEILING PLANS FOR CEILING

HEIGHTS.

ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU

WALL, AND FINISH FACE OF GYPSUM BOARD WALL, UNLESS

NOTED OTHERWISE.

THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0"

UNLESS NOTED OTHERWISE.

REFERENCE FURNITURE PLANS FOR LOCATIONS OF WALL

ACCESSORIES AND VISUAL DISPLAY EQUIPMENT. PROVIDE

BLOCKING AS REQUIRED TO SUPPORT ELEMENT ATTACHMENT.

TYPICAL DOOR JAMB LOCATION IS 0'-4" FROM ADJACENT

FINISHED WALL UNLESS DIMENSIONED OTHERWISE. REFER

SHEET AG003 FOR ACCESSIBLE DOOR CLEARANCES.

US Army Corps of Engineers ®

SHEET ID

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

B L E

G R

E

ID

E L

A F

D R

A W

IN

G

C O

D E

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

N U

E O

M A

H A

N

E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F

X B

M F

Y

B -2

W

A S

H R

A C

K A

N D

M A

IN

T

E N

A N

C E

H A

N G

A R

W

A S

H R

A C

K

O C

T O

B E

R

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A

M -0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

O C

T

A-111

G R

O U

N D

F L O

O R

P L A

N

A R

E A

A

T K

IM

J C

O B

L E

R

B C

H A

P M

A N

SCALE: 1/8" = 1'-0"

A1

GROUND FLOOR PLAN - AREA A

0 4' 8' 16'

SHEET KEYNOTES

1.6 ROOF OVERHANG ABOVE

1.7 STRUCTURAL STEEL FRAMING (PAINTED), TYPICAL (RE:

STRUCTURAL)

1.8 CANOPY ABOVE

1.10 EYE WASH STATION (RE: MECHANICAL)

1.11 FLOOR TRENCH DRAIN (RE: STRUCTURAL AND MECHANICAL)

1.12 BOLLARD - RE: A1 / A-521 OR A7 / A-521

1.13 DRAFT CURTAIN ABOVE

1.15 HANGAR DOOR WITH INSULATED METAL PANEL

1.18 MEP EQUIPMENT (RE: MECHANICAL AND ELECTRICAL)

1.19 MEP EQUIPMENT (RE: MECHANICAL AND ELECTRICAL)

1.20 DOWNSPOUT / SPLASH BLOCK RE:CIVIL

1.29 SHIPS LADDER

1.36 DOOR CONTROL PANEL (RE: ELECTRICAL)

1.38 FIRE EXTINGUISHER

PLAN

NORTH

KEY PLAN

C

D

E

F

1615147 8 9

A1

A-313

11 12

AREA A AREA B AREA B AREA C

AREA A AREA B AREA B AREA C

9' - 8" 29' - 4" 22' - 8" 3' - 11" 7' - 10" 21' - 2" 7' - 10" 3" 26' - 4" 29' - 4"

COMM

ELEC

MECH / AHU

106PUMP/FOAM

BOILER

MENS

WASH BAY EQUIP

MULTI-PURPOSE

OPEN OFFICE

SOAP

SECURE OFFICE

SOAP

STORAGE

HANGAR BAY 2

HANGAR BAY 1

CORRIDOR

JAN

VEST 2

110VEST 1

FLIGHT LINE

VESTIBULE

ENTRY VESTIBULE

SECURE VEST

WOMENS

NURSING

STORAGE

26' - 8"

A7

A-311

114A 110A114B 110B

111B

111A

124A

119A

121A 102C

108C

128B

128A

128C

109A 101E

118A

123A

101H

109H

112B

112A

122A

1' - 4" 20' - 8"

1' - 4"

3'

0"

10' - 0"

8"

18' - 0"

6'

1'

M5CA

M5CA

M5CA

M1CA

S2CA

M1CA

M1CD

M1CA

M1CD

M1CB

M1CB

M1CB

M1CA

M1CA M1CA

M1DB M5CA

M1CD

M1CD

M1CA

M1CB

S1CA

M1CA

M1CA

S1AB

M1CA

M1DB

S1CA

M1CA

M1CD

M1CD

S1CA

M1CB

S2CA

8' - 8" 6' - 3" 6' - 9 3/8" 11"

1' - 4" 29' - 4"

1' - 4"

9'

6'

7' - 7"

5'

8'

0"

11' - 4 3/8" 13' - 4" 5' - 4" 3' - 4" 6'

9'

8'

11' - 0" 3' - 3"

1' - 4" 9' - 6" 9' - 0" 1' - 4"

1'

1'

1.12 1.12

1.12

1.20

3'

0"

1' - 4"

1' - 4"

102A

102B 103A 104A 105A

6'

2'

A15

A-310

A1

A-310

A1

A-311

A1

A-312

1.6 1.6

1.30

99' - 6 1/4"

1.8

99' - 6 1/4"

E1

A-421

A1

A-422

2' - 8" 1.2

1.2

2' - 8"

1.7

A1

A-401

1.27

1.27

3' - 4"

M5CA

S2CA

M1CB

11' - 0" 1' - 4"

1.12

1.12

MENS SHOWER

WOMENS SHOWER

99' - 6 1/4"

1/

/ 1

2"

1.13

1/

/ 1

2"

99' - 6 1/4"

1.13

8' - 0"

M5CA

115A

129A

117A

EQ EQ

12' - 4" 2' - 7" 3' - 6"

1' - 9" 10"

4' - 11"

2' - 7"2' - 11"

9' - 8" 8' - 0"

1'

120A

1.11 1.11

1.10

1.151.15

1.28 1.28

1.301.30

1.30

10' - 0"

1.16 126A

126B

A1

A-403

K1

A-630

A5

A-312

L8

A-402

10 13

1.27

99' - 6 1/4" 99' - 6 1/4"

6' - 8"

10' - 0" 9' - 4" 4' - 8"

4' - 5"

3' - 8"

1' - 4" 12' - 8" 10' - 0"

6' - 4"

S1AC

1:20

1:

1:

1:20

A1

A-314

12' - 1"

A13

A-311

1:

20 1:

100' - 0"

100' - 0"

100' - 0"

105B

106A 107A

108A 108B

M5CA

A8

A-313

1.11

A16

A-313

1.3

116A

3' - 7"

M1DB

M5CA

3' - 7"

127A

M1CA

C13

A-411

C13

A-411

OPP

ABOVE

ABOVE

A8

A-314

1.10

G13

A-521

A13

A-521

ABOVE

1.29

UP

G13

A-521

A13

A-521

100' - 0"

100' - 0"

1.10

1.12 TYP

1.8

M1CA

M1CA

1.10

1.29

26' - 8" 3' - 4"

UP

OPP

ABOVE

OPP

1.18

1.34

1.34

1.10

E1

A-402

E8

A-402

A1

A-420

1.38

F1

A-420

K14

A-41299' - 10"

1.301.30

100' - 0" 100' - 0"

1.301.30

99' - 10"

M1CA

S2CA

M1CA

M1CD

S1ABS1AB

S1AB

M1CA

M1CA

M1DA

M1CA

100' - 0"

100' - 0"

1.12

M1CB

1.38

S2CA

M1CA

GENERAL SHEET NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND,

AND ABBREVIATIONS REFER TO SHEET AG001 & AG002.

REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS.

FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION

REFER TO PARTITION TYPES SHEET A-501 THRU A-503.

FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT

ILLUSTRATED, REFER TO LARGER SCALE DRAWINGS.

REFERENCE THE REFLECTED CEILING PLANS FOR CEILING

HEIGHTS.

ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU

WALL, AND FINISH FACE OF GYPSUM BOARD WALL, UNLESS

NO…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .