Am_0003 - D .PDF
PDF 6 MB Posted
- Attached to
- Logistics Readiness Squadron Campus, Offutt AFB, Nebraska Federal contract opportunity
- Solicitation number
- W9128F21R0026
About this file
This federal solicitation seeks proposals for a construction project at Offutt Air Force Base in Nebraska. The project includes demolishing existing substandard warehouse space and constructing a new consolidated warehouse facility with logistics and administration areas, shipping and receiving operations areas, open storage areas, and loading/unloading aprons. Supporting facilities encompass underground utilities, electric service, paving, sanitary sewer system, storm drainage, information systems, fire suppression systems, landscaping, and site improvements. Heating and air conditioning will utilize self-contained systems. Facilities require all necessary site work, utilities, mechanical, electrical, fire protection systems, backup power, and other required support. Force protection incorporates reinforced exterior walls, blast-proof windows, and passive barriers. The overall project also includes the safe removal of multiple facilities, with sustainable principles integrated into design, development, and construction per applicable laws and Executive Orders.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Am_0006-Drawings.PDF | ||
| Am_0006.pdf | ||
| Am_0005.pdf | ||
| Am_0004.pdf | ||
| Am_0004 - D.pdf | ||
| Am_0003.pdf | ||
| OF63 LRS CAMPUS OFFUTT AFB AM 0002.PDF | ||
| Am_0002.pdf | ||
| Am_0001-Drawings.pdf | ||
| Am_0001.pdf | ||
| LRS Campus Drawings Part 1 of 2.pdf | ||
| W9128F-21-R-0026_SPECS.pdf | ||
| LRS Campus Drawings Part 2 of 2.pdf.pdf |
Show all 13
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ST
CB
B U
IL
D
IN
G
B U
IL
D
IN
G
B U
IL
D
IN
G
8' METAL FENCE
LIFT GATE
BU
TLER
BLVD
APOLLO ROAD
M
IN
U T E
M A
N
C
IR
C L E
CB
CB
CB
S
S
D
D
D
D
CB
DD
D
CI
MW
D
MW
33'
TRUCK SCALE
FENCE
EXISTING
TIE INTO
TO REMAIN
LOADING RAMP
DETAILS ON SHEET CS503
MANUAL FE-6 SLIDE GATE
DETAILS ON SHEET CS504
FE-6 SLIDE GATE
DETAILS ON SHEET CS504
FE-6 SLIDE GATE
HANDICAP RAMP
STAIR DETAILS FOUND ON CS501
STAIR DETAILS FOUND ON CS501
REPLACE EXISTING CONCRETE
FOR MECHANICAL ROOM
VEHICLE ACCESS RAMP
FENCE
EXISTING
TIE INTO
POV PARKING
SEE SHEET CS505
FENCE DITCH CROSSING
DETAILS ON CS502
SECURITY FENCE
FE-6 CHAIN-LINK
DETAILS ON CS502
SECURITY FENCE
FE-6 CHAIN-LINK
INTEGRAL CURB
INTEGRAL CURB
NEW RIM ELEVATION = 969.85'
PAVEMENT ELEVATION
MANHOLE RAISED 1.5' TO MEET NEW
LOADING DOCK RAMP
INTEGRAL CURB
LOADING DOCKLOADING DOCK
IN PLACE
MANHOLE REMAINS
DETAILS ON CS502
FE-6 CHAIN-LINK SECURITY FENCE
EXISTING FENCE
TIE INTO
ELECTRICAL SHEETS
MORE INFORMATION ON
ELECTRICAL EQUIPMENT
DETAILS ON CS501
PIPE GUARDS
DETAILS ON CS501
PIPE GUARDS
DETAILS ON CS501
PIPE GUARDS
DETAILS ON CS501
PIPE GUARDS
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
N 492,230.33
E 2,765,677.90
N 492,228.14
E 2,765,619.89
N 492,056.50
E 2,765,666.66
N 491,848.97
E 2,765,570.18N 491,861.15
E 2,765,389.62
N 491,966.84
E 2,765,356.28
N 492,110.40
E 2,765,612.12
N 492,101.43
E 2,765,626.48
N 491,953.92
E 2,765,467.08 N 491,953.92
E 2,765,507.08
N 492,242.68
E 2,765,399.57
N 491,898.89
E 2,765,543.85
N 491,977.89
E 2,765,661.47
N 491,966.88
E 2,765,638.13
N 492,124.94
E 2,765,391.80
N 492,152.34
E 2,765,381.58
N 491,856.97
E 2,765,467.08
R
N 492,234.13
E 2,765,620.29
N 492,295.34
E 2,765,576.01
N 492,307.86
E 2,765,682.62
N 492,264.42
E 2,765,680.62
N 492,263.79
E 2,765,688.79
N 491,850.18
E 2,765,573.22
R
N 491,970.12
E 2,765,588.91
R
R
N 491,989.05
E 2,765,604.20
N 491,979.74
E 2,765,587.34
N 491,989.05
E 2,765,633.57
N 492,017.09
E 2,765,663.59
R
R 25'
R
R
R = 10'
R
N 492,029.62
E 2,765,361.36
N 492,058.46
E 2,765,375.39
N 492,083.30
E 2,765,353.25
N 492,006.87
E 2,765,346.70
N 492,268.74
E 2,765,612.38
N 491,826.36
E 2,765,436.01
N 491,900.29
E 2,765,537.08
N 491,859.82
E 2,765,423.25
N 491,964.54
E 2,765,430.16
N 491,966.74
E 2,765,396.69
N 492,087.05
E 2,765,389.30
KEYPLAN SCALE: 1" = 500'
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg8:10:32 PM 8/30/2021
...\OF\OF63\40000 Design Products\CAD_BIM\_Sheets\CS101
F -2
-0
O
C S .d g n
L
G
IS
T
IC
S R
E A
D
IN
E S
S S
Q U
A D
R O
N C
A M
P U
S
O F F
U T
T F
L O
O D R
E C
O V
E R
Y
O F F
U T
T A
F B
N E
B R
A S
K A
/2
/2
M
A H
A
N E
C
A P
IT
O L A
V E
O M
A H
A D
IS
T R
IC
T
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
30' 60'0
SCALE: 1" = 30'-0"
N
S
IT
E P
L A
N
CS101
D F
E C
H N
E R
D F
E C
H N
E R
A N
S I
D
W
C
D A
V E
N P
O R
T
W
C
D A
V E
N P
O R
T
LEGEND
SEE SHEET CP502 FOR TYPICAL SECTION
CONCRETE PAVEMENT
SEE SPEC 32 92 19 FOR DETAILS
SEEDED AREAS
W F -2
-R -0
A
M G
E N
E R
A L R
E V
IS
IO
N S
-0
-2
A
M G
E N
E R
A L R
E V
IS
IO
N S
-0
-2
LINE POST
TOP RAIL OR TENSION WIRE
BRACE RAIL
(TYP.)
TIE WIRES
(3/8" MIN. DIA.)
TRUSS ROD
CONCRETE BASE
OR PULL POST
CORNER, END,
TIE WIRES (TYP.)
LINE POST
GRADE
WIRE
TENSIONOF FABRIC
BOTTOM
(9 GAGE, 2" MESH)
CHAIN-LINK FABRIC
BASE
CONCRETE
(3/8" MIN. DIA.)
TRUSS ROD
BAND
TENSION
(3/8" MIN. DIA.)
TRUSS ROD
WIRE
TENSION
CARRIAGE BOLT
TENSION BAR
EACH FABRIC LINK
TENSION BAR TO ENGAGE
FABRIC
TOP AND BOTTOM OF FABRIC)
(15" O.C. MAX. AND WITHIN 4" FROM
TENSION BAND
FABRIC
(2'-0" O.C. MAX.)
9-GAGE TIE WIRES
OF FABRIC)
TOP AND BOTTOM
WITHIN 4" FROM
(15" O.C. MAX AND
TIE WIRE
OF FABRIC)
TOP AND BOTTOM
WITHIN 4" FROM
(15" O.C. MAX AND
TIE WIRE
STEEL GROUND ROD
3/4" DIA. COPPER-CLAD
OF COPPER
CLAMP-TYPE FITTING
WELD OR APPROVED
MOLDED EXOTHERMIC
COPPER WIRE
#8 AWG SOLID
FENCE POST
TRUSS ROD TRUSS ROD
LINE POSTLINE POST BRACE RAILS
RAILS
BRACE
PULL POST
TENSION WIRE
TOP RAIL OR
(TYP.)
TIE WIRES
ON EXTENSION ARMS
BARBED-WIRE APRON
RIVETED FLUSH (TYP.)
" PLAIN PIN8
RIVETED FLUSH (TYP.)
3/8" PLAIN PIN
LOCK PIN (TYP.)
WIRE (TYP.)
BARBED
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N M
A R
K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
A
B
C
D
E
F
G
1 98765432
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg8:17:07 PM 8/30/2021
...\OF\OF63\40000 Design Products\CAD_BIM\_Sheets\OF63CS502
C S .d g n
L
G
IS
T
IC
S R
E A
D
IN
E S
S S
Q U
A D
R O
N C
A M
P U
S
O F F
U T
T F
L O
O D R
E C
O V
E R
Y
O F F
U T
T A
F B
N E
B R
A S
K
M
A H
A
N E
C
A P
IT
O L A
V E
O M
A H
A D
IS
T R
IC
T
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
NO SCALE
16" MIN. DIA.
M
IN
M
IN
10'-0" MAXIMUM
LINE POSTS TO BE EQUALLY SPACED
10" MIN. DIA.
NO SCALE
FASTENING DETAILS
TRUSS ROD AND BAND
ROUND POST
BRACE RAIL CLAMP DETAILS
H-BEAM
TENSION BAND DETAIL
END OR GATE POST DETAIL
(T
Y P
2.25" x 1.70"
2.375" O.D. 2.875" O.D.
2.25" x 1.70"
1.90" O.D.
2.25" x 1.70"
2.00" SQ.
2.375" O.D. 2.875" O.D.
2.50" SQ. 3.00" SQ.
4.00" O.D.
1.66" O.D.
1.50" O.D.
1.625" x 1.50"H-SECTION
TUBULAR - SQUARE
TUBULAR - ROUND
TOP, BOTTOM & BRACE RAILS
TUBULAR - ROUND
LINE POSTS
TUBULAR - SQUARE
TUBULAR - ROUND
CORNER, END & PULL POSTS
USE AND SECTION
FABRIC LESS THAN 72"
MINIMUM OUTSIDE DIMENSIONS (NOMINAL)
STEEL POST SCHEDULE
FABRIC 72" TO 96" FABRIC OVER 96"
NOTES:
FINAL NUMBER IS FABRIC WIDTH IN INCHES
TWBR - FENCE WITH TOP TENSION WIRE AND BOTTOM RAIL
TWB - TENSION WIRE TOP AND BOTTOM
TBR - FENCE WITH TOP AND BOTTOM RAILS
TR - FENCE WITH TOP RAIL AND TENSION WIRE AT BOTTOM
ON DOUBLE OUTRIGGER
TYPE FE8 - CHAIN-LINK FENCE W/BARBED-WIRE AND BARBED-TAPE
TYPE FE7 - CHAIN-LINK FENCE W/BARBED-WIRE ON DOUBLE OUTRIGGER
TYPE FE6 - CHAIN-LINK FENCE W/BARBED-WIRE ON SINGLE OUTRIGGER
TYPE FE5 - CHAIN-LINK FENCE WITHOUT BARBED-WIRE APRON
FENCE LEGEND:
EXAMPLES:
FABRIC WIDTH.
TOP AND BOTTOM TENSION WIRE, AND 48 INCH
FE5-TWB-48 - CHAIN-LINK SECURITY FENCE WITH NO APRON,
WIDTH.
ON SINGLE OUTRIGGER, TOP RAIL, AND 72 INCH FABRIC
FE6-TR-72 - CHAIN-LINK SECURITY FENCE WITH BARBED-WIRE
H-BEAM ROUND POST
LINE POST ATTACHMENTS
TOP OR BRACE RAIL ATTACHMENT
GROUNDING DETAIL
NO SCALE
NO SCALE
BRACE PANEL DETAIL
10'-0" MAX. 10'-0" MAX.
NOTE:
STRAIGHT RUNS EXCEED 500 FEET.
PROVIDE BRACE PANEL WHENEVER
10'-0" MAXIMUM
X X X X X X
XX
X XXXXXXXXXXX
X
X X X X X X
X X X X XXXXX
X X X X X X X
XXXXXX
X X X X X X
X X X X
XXXX
X X X X X X X
XXX
X X X
X X X X X
XXXXX
X X X X X
X
X
X
X
X
X X
X X
X X
X
XXX
X
X
X
NO SCALE
EXTENSION ARM DETAILS
LINE POST CORNER POST
1'-0"
45 DEGREES
1' -6 " 6"
T Y P
1' -1 0" 7.
5" (T
YP.
35 DEGREES
X X X X X
XXXXX
X X X X X
X X X X
X
XX
XXX
X X
X X X X
XXXX
X X X X
X X X X
XXXX
X X X X
X
X
X X
X
X
H-SECTION
FE6 CHAIN-LINK SECURITY FENCE DETAIL
PROTECTED.
SHALL HAVE APRON EXTENDED OUTWARD FROM THE AREA BEING
3. UNLESS OTHERWISE SHOWN OR SPECIFIED, ALL FE6 FENCE
SECURE AREA.
FABRIC SHALL BE PLACED ON THE OPPOSITE SIDE OF THE
ON THE SECURE SIDE OF THE FENCE ALIGNMENT. CHAIN-LINK
2. WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED
MANUFACTURER.
NOT INTENDED TO LIMIT METHOD OF INSTALLATION TO ONE
1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE
W
C
D A
V E
N P
O R
T
F E -6 F
E N
C E D
E T
A
IL
S
CS502
D F
E C
H N
E R
D F
E C
H N
E R
A N
S I
D
/2
/2
W
C
D A
V E
N P
O R
T
W F -2
-R -0
A F -2
-0
F
A B
R
IC
W
ID
T
H
A
M G
E N
E R
A L R
E V
IS
IO
N S
-0
-2
3 4 5 6 7 8 9 10
C
B
7737 SF
SHIPPING/
RECEIVING
A-301
A-302
/2
2' - 8" 3' - 4" 3' - 8" 12' - 0" 10' - 0" 15' - 4" 8' - 4" 12' - 0" 2' - 8" 3' - 4" 14' - 0" 9' - 4" 12' - 0" 15' - 4" 34' - 8"
3'
/2
6'
8" 3'
4"
3'
4"
3'
4"
/2
/1 A-112
A-
119B
2A
122B 122C 122D
2E
1"
1' -0
" 48
RAMP
UP
100' - 0"
96' - 0"
96 SF
ELECTRICAL
560 SF
CARGO
OUTBOUND
617 SF
WOOD
SHOP
W-2
122F 122G
2H
W-2
24' - 9"
0"
A-301
A-403
DN DN DN
W-4
W-4
W-3
HYDRAULIC
DOCK LEVELER
HYDRAULIC
DOCK LEVELER
A-471
A-471
A-471
1"
1' -0
GENERAL NOTES:
1. ALL CHANGES IN FLOOR MATERIALS IN DOOR OPENINGS SHALL
OCCUR AT THE CENTER LINE OF THE DOOR PANEL IN THE CLOSED POSITION UNLESS
NOTED OTHERWISE.
2. ROOM FINISH SCHEDULES MAY BE FOUND ON A-603 SHEET.
3. DOOR SCHEDULES MAY BE FOUND ON A-603 SHEET.
4. WINDOW SCHEDULES MAY BE FOUND ON A-603 SHEETS.
5. SEE A-601 FOR WALL TYPE DETAILS
6. PROVIDE GWB CONTROL JOINTS @ 30'-0 OC MAX SPACING ON ALL
EXPOSED GWB SURFACES.
PROVIDE AT CORNERS OF DOOR OR WINDOW OPENINGS OR EDGES OF
CEILING FEATURES WHENEVER POSSIBLE.
7.DO NOT SCALE FROM DRAWINGS.
8.SEE CIVIL SITE PLAN FOR BUILDING LOCATION
9.CONTRACTOR SHALL VERIFY SIZE AND LOCATION OF ALL WINDOW,
DOOR, LOUVER, AND OTHER OPENINGS
PRIOR TO MANUFACTURING OR INSTALLING ANY SUCH ITEM. ALL
OPENINGS SIZES ARE NOMINAL.
CONTRACTOR SHALL VERIFY THE ACTUAL SIZE REQUIRED FOR EACH OPENING.
10.SEE STRUCTURAL DRAWINGS FOR CONTROL JOINT LOCATIONS
11.DOOR OPENINGS IN STUD WALLS SHALL BE LOCATED 4" AWAY
FROM ADJACENT PERPENDICULAR WALLS.
12.DOOR OPENINGS IN MASONRY WALLS SHALL BE LOCATED 8" AWAY
NOMINALLY FROM ADJACENT PERPENDICULAR WALLS.
13.SEE SHEET F-100 FOR FEB LOCATIONS.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
A-113
SH
IP
PI
N
G
R
EC
EI
VI
N G
(S O
U
TH
) A R
EA
F
LO
O
R
PL
AN
O
FF
U
TT
A
FB
, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
A.
P
AR
KE
R
A.
P
AR
KE
R
B.
G
O R
U P
B.
G
O R
U P
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O
VE
R Y
LO
G
IS
TI
C S
R
EA
D
IN
ES
S
SQ
U
AD
R
O N
C
AM
PU
S
O F6
3_
LR
S-
AR
C H
.rv t
1/8" = 1'-0"1 SHIPPING / RECEIVING (SOUTH) AREA FLOOR PLAN
KEY PLAN
WAREHOUSE
SHIPPING /
RECEIVING
ADMIN
PLAN NORTH
8'0 4' 16'
AM
G
EN
ER
A L R
EV
IS
IO
N
S
-0 1-
FIRST FLOOR
100' - 0"
A
8" CMU WALL, CMU-3, SEE
STRUCTURAL FOR
REINFORCING AND BRACING
REQUIRMENTS
1" AIR GAP
1" METAL LINER PANEL,
AS SCHEDULED, OVER 6"
STEEL STUDS, R-18
CONCRETE SLAB ON GRADE
10" CAST-IN-PLACE
CONCRETE FOUNDATION,
SEE STRUCTURAL
PRE-ENGINEERED
METAL BUILDING
RIGID FRAME, SEE
STRUCTUAL
CAPPILARY
WATER BARRIER
VAPOR BARRIER
RIGID INSULATION UNDER SLAB-ON-
GRADE - EXTENDS 4' FROM FOUNDATION
PER ASHRAE REQUIREMENT; R - 15
RIGID PEREMTER INSULATION; R - 7.5
FIRST FLOOR
100' - 0"
C
CONCRETE SLAB
ON GRADE
8" CMU WALL, CMU-1, SEE
STRUCTURAL FOR
REINFORCING AND BRACING
REQUIRMENTS
1" AIR GAP
1" METAL LINER PANEL, AS SCHEDULED,
OVER 6" STEEL STUDS, R-18
PRE-ENGINEERED METAL
BUILDING RIGID FRAME, SEE
STRUCTUAL
10" CAST-IN-PLACE CONCRETE FOUNDATION,
SEE STRUCTURAL
RIGID PERIMETER
INSULATION; R-7.5
RIGID INSULATION UNDER
SLAB-ON-GRADE - EXTENDS 4'
FROM FOUNDATION PER
ASHRAE REQUIREMENT; R - 15
VAPOR BARRIER
CAPPILARY WATER BARRIER
9 1/2"
FIRST FLOOR
100' - 0"
CONCRETE FOUNDATION,
SEE STRUCTURAL
CONCRETE SLAB ON GRADE
INTERIOR METAL RUNNER
8" CMU WALL, SEE
STRUCTURAL FOR
REINFORCING
AND BRACING
REQUIREMENTS
1" AIR GAP
FIRST FLOOR
100' - 0"
8" CMU WALL, SEE
STRUCTURAL FOR
REINFORCING AND
BRACING
REQUIREMENTS
INTERIOR METAL
RUNNER
1" AIR GAP
CONCRETE FOUNDATION,
SEE STRUCTURAL
1" METAL LINER PANEL,
AS SCHEDULED,
OVER INSULATED STEEL
STUD, R-18
RIGID INSUALTION; R-15
RIGID PERIMETER INSULATION; R-7.5
VAPOR BARRIER
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
A-500
W
AL
L
BA
SE
D
ET
AI
LS
O
FF
U
TT
A
FB
, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
A.
P
AR
KE
R
A.
L
U
KE
N S
B.
G
O R
U P
B.
G
O R
U P
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O
VE
R Y
LO
G
IS
TI
C S
R
EA
D
IN
ES
S
SQ
U
AD
R
O N
C
AM
PU
S
O F6
3_
LR
S-
AR
C H
.rv t
1 1/2" = 1'-0"1 HIGH BAY WALL BASE DETAIL @ GRADE
1 1/2" = 1'-0"2 HIGH BAY WALL BASE @ DOCK
AM
G
EN
ER
A L R
EV
IS
IO
N
S
-0 9-
AM
G
EN
ER
A L R
EV
IS
IO
N
S
-0 1-
1 1/2" = 1'-0"3 WALL BASE @ EXPANSION JOINT
1 1/2" = 1'-0"4 HIGH BAY WALL BASE DETAIL @ RETAINING WALL
0 1'6"3" 1' 6"
T.O. ADMIN
116' - 0"
A
4" INSULATED METAL PANEL,
MP-1 ON STEEL GIRTS, SEE
STRUCTURAL
5/8" GYP BD. AS
SCHEDULED, OVER
INSULATED 6" STEEL
STDS
1" AIR GAP
GALVINIZED STEEL Z BAR
FLASHING
2 1/2" INSULATION FILL
APPROVED SEALANT AND
BACKER ROD
A-608
T.O. ADMIN
116' - 0"
C
INSULATED GLAZING UNIT
(IGU), SEE SCHEDULE
STANDING SEAM METAL
CANOPY ON PURLINS; SEE
STRUCTURAL (BEYOND)
8" CMU WALL, CMU-1, SEE
STRUCTURAL FOR
REINFORCING AND BRACING
REQUIRMENTS
1" METAL LINER PANEL, AS
SCHEDULED, OVER
INSULATED GIRT PLANE
1" AIR GAP
GALVANIZED METAL Z BAR
FLASHING (BEYOND)
APPROVED SEALANT (BEYOND)
APPROVED SEALANT
4" INSULATED METAL PANEL,
MP-1, ON STEEL GIRTS (BEYOND),
SEE STRUCTURAL
A-608
C
8" CMU WALL, SEE
STRUCTURAL FOR
REINFORCING AND
BRACING REQUIRMENTS
1" METAL LINER PANEL, AS
SCHEDULED, OVER 6" STEEL
STUDS, R-18; CUT TO
CONTOUR OF THE STEEL
DECK, BUT ALLOW FOR 1"
DEFLECTION
1" METAL LINER PANEL, AS
SCHEDULED, OVER
INSULATED GIRT PLANE
1" AIR GAP
FILL GAP WITH FIRE CAULK /
SEALANT
DEEP LEG DEFLECTION TRACK
1/2" STEEL ROOF DECKING
T.O. WOODSHOP
112' - 0"
SEE STRUCTURAL SHEETS
FOR DECK SUPPORT TO
CMU WALL
T.O. ADMIN
116' - 0"
5" POLYISO INSULATION
PER ASHRAE
REQUIREMENTS
8" CMU
5/8" COVER BOARDA-470
5/8" GYP BD. AS SCHEDULED,
OVER INSULATED 6" STEEL
STDS, R-18
1" AIR GAP
8" CMU BOND BEAM, NOTCHED
AROUND JOIST; SEE
STRUCTURAL
1/2" STEEL ROOFING DECK
STEEL JOIST; SEE STRUCTURAL
5/8" GYP BD. AS
SCHEDULED OVER 2 1/2"
STEEL STUDS; CUT GWB
TO CONTOUR OF THE
STEEL DECK BUT ALLOW
FOR 1" DEFLECTION
T.O. WOODSHOP
112' - 0"
B
EXPANSION JOINT
1/2" STEEL ROOF DECKING
8" CMU WALL; SEE
STRUCTURAL FOR
BRACING AND
REINFORCEMENT
REQUIREMENTS
T.O. WOODSHOP
112' - 0"
1/2" STEEL DECK
8" CMU
1" AIR GAP
STEEL JOIST
2 1/2" STL STUDS @
16" OC W/ 5/8" GWB;
CUT TO CONTOUR OF
THE STEEL DECK BUT
ALLOW FOR 1"
DEFLECTION
JOIST BOLTED TO
BEARING PLATE
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
A-510
W
AL
L D
ET
AI
LS
O
FF
U
TT
A
FB
, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
A.
P
AR
KE
R
A.
L
U
KE
N S
B.
G
O R
U P
B.
G
O R
U P
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O
VE
R Y
LO
G
IS
TI
C S
R
EA
D
IN
ES
S
SQ
U
AD
R
O N
C
AM
PU
S
O F6
3_
LR
S-
AR
C H
.rv t
1 1/2" = 1'-0"1 METAL PANEL TO CMU WALL TRANSITION (TYP)
1 1/2" = 1'-0"2 CANOPY CONNECTION DETAIL
1 1/2" = 1'-0"3 WALL DETAIL @ GRIDLINE "C" 3
AM
G
EN
ER
A L R
EV
IS
IO
N
S
-0 1-
1 1/2" = 1'-0"4 VERTICAL EXPANSION JOINT
1 1/2" = 1'-0"5 WALL DETAIL @ GRIDLINE "10"
1 1/2" = 1'-0"6 WALL DETAIL @ INTERIOR CMU
1 1/2" = 1'-0"7 WALL DETAIL @ INTERIOR CMU
0 1'6"3" 1' 6"
STL DECK
2 1/2" SOUND ATTENUATION BATTS
6" M
IN
1B 1C 1D
NO SOUND ATTENUATION BATTS
5/8" GWB ON ROOM SIDE ONLY
USE 6" STL STUD IN LIEU OF
3/58" STL STUD
EXTEND STUD AND GWB TO STL
DECK WHERE EXPOSED
STRUCTURE CEILING IS
SCHEDULED
CEILING AS SCHEDULED (SEE ROOM
FINISH SCHEDULE) - BOTH SIDES
WHERE FINISH CEILING IS REQ'D,
ALT BRACING DETAIL 1/A-410 MAY
BE USED.
3-5/8" STL STUDS @ 16"
OC W/ 5/8" GWB - BOTH
SIDES
WALL BASE AND FLOOR FINISH AS
SCHEDULED (SEE ROOM FINISH
SCHEDULE) - BOTH SIDES
STL STUD RUNNER TRACK
BACKER ROD & SEALANT, BOTH
SIDES, CONT. (TYP.)
1ETAKE GWB AND STL MESH
TO BOTTOM OF DECK, GWB
BOTH SIDES
16 GA EXPANDED
STL MESH @
EXTERIR FACE
(NON-SECURE),
TYPE 1E ONLY
6" M
IN
2BUSE 2-1/2" STL STUD IN LIEU OF 6" STL STUD
EXTEND STUD AND GWB TO STL
DECK WHERE EXPOSED
STRUCTURE CEILING IS
SCHEDULED
CEILING AS SCHEDULED (SEE ROOM
FINISH SCHEDULE)
6" STL STUDS @ 16" OC
W/ 5/8" GWB
WALL BASE AND FLOOR FINISH AS
SCHEDULED (SEE ROOM FINISH
SCHEDULE)
STL STUD RUNNER TRACK
FACE OF MASONRY WALL TO BE
FURRED
1/2"
PROVIDE ANCHOR CLIPS @ 48" OC
MAX
STL DECK
CEILING AS SCHEDULED (SEE ROOM
FINISH SCHEDULE) - BOTH SIDES
CMU WALL - SLAB AND BEARING
CONDITION VARIES - SEE
STRUCTURAL DRAWINGS
FLOOR FINISH AS SCHEDULED
(SEE ROOM FINISH SCHEDULE)
SEAL ALL THRU-WALL
PENETRATIONS - SIM
DTL B/A-730
8" CMU WALL - SEE STRUCTURAL
DRAWINGS FOR REINFORCEMENT
AND BRACING REQUIREMENTS.
HEAD CONDITION VARIES -
SEE STRUCTURAL DRAWINGS
FOR BRACING REQUIREMENTS
SPRAY FOAM HEAD
CONDITION FOR CONTINUOUS
ACOUSTICAL SEAL
SEE DETAIL1/A-412
8" GROUTED CMU WALL - SEE
STRUCTURAL DRAWINGS FOR
REINFORCEMENT AND BRACING
REQUIREMENTS.
1"
1/ 2"
M
IN
3"
ALLOW FOR 1" FOR
DEFLECTION
STUD TOP TRACK, SET
INTO DEFLECTION
TRACK
STL JOIST
DEEP LEG
DEFLECTION TRACK,
FASTENED TO
STRUCT. MEMBER
GWB AS INDICATED -
DO NOT FASTEN TO
DEFLECTION TRACK
1"
COMPRESSIBLE INSULATION
GWB CUT TO CONTOUR OF
THE STEEL DECK, BUT
ALLOW FOR 1" DEFLECTION
DEEP LEG DEFLECTION
TRACK FASTENED TO DECK
STUD TOP TRACK, SET INTO
DEFLECTION TRACK
INSULATION AS REQ'D
STEEL DECK
ACOUSTICAL
SEALANT
GWB AS INDICATED -
DO NOT FASTEN TO
DEFLECTION TRACK
TOP OF WALL PERPENDICULAR TO STEEL DECK FLUTES
TOP OF WALL PARALLEL TO STEEL DECK FLUTES - SIM. TO DETAIL 4/A-411. SPAN FLUTES WITH
20 GA. SHEET METAL AS NEEDED TO ANCHOR STUD WALL
ACOUSTICAL SEALANT AT
GAP
COMPRESSIBLE INSUL.
GWB CUT TO CONTOUR OF
THE STEEL DECK, BUT
ALLOW FOR 1" DEFLECTION
DEEP LEG DEFLECTION
TRACK FASTENED TO DECK
TOP OF WALL PERPENDICULAR TO STEEL DECK FLUTES
4" 1"
TOP OF WALL PERPENDICULAR TO STEEL DECK FLUTES - ABOVE
MIN. 4 PCF DENSITY MINERAL WOOL
INSULATION AT FIRE RATED WALLS.
CUT TO THE SHAPE OF FLUTED DECK,
25% LARGER & COMPRESS TO FIT
1/2" GAP - FILL W/ FIRESTOP SEALANT
DEFLECTION TRACK W/ OFFSET DEEP
LEGS TO ACCOMMODATE GWB
THICKNESS, SIM. TO "FIRE TRAK
CORP." PRODUCTS - FASTEN TO DECK
5/8" TYPE 'X' GWB - CUT TO CONTOUR
OF THE STEEL DECK AND FASTENED
TO DEFLECTION TRACK
STEEL
DECK
5/8" TYPE 'X' GWB -
DO NOT FASTEN TO
DEFLECTION
TRACK )DETAIL IS
SIM. FOR DOUBLE
GWB AND SHAFT
WALL SYS.)
FILL GAP W/ FIRE CAULK /
SEALANT
DEFLECTION TRACK W/
OFFSET DEEP LEGS
MINERAL WOOL
INSULATION
5/8" TYPE 'X' GWB
TOP OF WALL PERPENDICULAR TO STEEL DECK FLUTES
TOP OF WALL PERPENDICULAR TO STEEL DECK FLUTES -
ABOVE
FILL CAVITY WITH
OPEN-CELL SPF
STEEL
DECK
PROVIDE 20GA BENT PLATE - BOTH
SIDES - CUT TO PATTERN OF DECK
FLUTES WHERE HEAD CONDITION
IS EXPOSED TO VIEW - FIX TO
UNDERSIDE OF STEEL DECK ONLY
CMU WALL - SEE
STRUCTURAL FOR
BRACING
1" M
IN
VA
R
IE
S-
A
LL
O W
" M
IN
G
AP
6" M
IN
EXTEND STUD AND GWB TO STL
DECK WHERE EXPOSED
STRUCTURE CEILING IS
SCHEDULED
CEILING AS SCHEDULED (SEE ROOM
FINISH SCHEDULE)
2 1/2" STL STUDS @ 16"
OC W/ 5/8" GWB
WALL BASE AND FLOOR FINISH AS
SCHEDULED (SEE ROOM FINISH
SCHEDULE)
STL STUD RUNNER TRACK
FACE OF PRECAST CONCRETE,
CAST IN PLACE CONCRETE, OR
MASONRY WALL TO BE FURRED
PROVIDE ANCHOR CLIPS @ 48" OC
MAX
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
A-601
W
AL
L
TY
PE
S
O
FF
U
TT
A
FB
, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
A.
P
AR
KE
R
A.
P
AR
KE
R
B.
G
O R
U P
B.
G
O R
U P
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O
VE
R Y
LO
G
IS
TI
C S
R
EA
D
IN
ES
S
SQ
U
AD
R
O N
C
AM
PU
S
O F6
3_
LR
S-
AR
C H
.rv t
1 1/2" = 1'-0"1 STL STUD BASIC PARTITION
1 1/2" = 1'-0"2 STL STUD FURRED WALL w/AIR
1 1/2" = 1'-0"3 CMU PARTITION
3" = 1'-0"5 TYP NON-RATED WALL HEAD DETAIL
3" = 1'-0"6 TYP SOUND-RATED WALL HEAD DETAIL
3" = 1'-0"7 TYP FIRE RATED WALL HEAD DETAIL
3" = 1'-0"8 CMU WALL HEAD
AM
G
EN
ER
A L R
EV
IS
IO
N
S
-0 1-
1 1/2" = 1'-0"4 STL STUD FURRED WALL
0 6"3" 9"
0 1'6"3" 1' 6"
S2
S2S2
S2
S2
F3
M2 M4
M4
M4
M4
M4
M4
M4
M4
M4
S7 S7 S7 S7 S7
S7
S7 S7 S7 S7 S7
S6M4
M5
S2
S2
M4
S1
F3 F3
F3
S1
M8
D6 S9
D4
D4
F5
S8
M6
M4
S1 S1
S1
S1
F6
F6
S8 S8
S8S8S8
D6
M4
D5
D5
M4 M4 M4M4M4 M4
D4
D4 D4 D4 D4
D4
S1
S1
S1 S1 S1
S1
S1
M4M4M4
M4M4
S1 S1 S1 D4 D4 D4
F1
S2 S2
S2 S2
M7
F2
F2
S9 S9
S9S9
T4
T6
T3
T3 S5 S5
S5S5
D2
S2 S2
T3 S5S5
S5 S5 T3
M3
S5S5S5 S5
S5 S5S5 S5
S5 S5S5 S5
S5 S5S5 S5
T3T3
T3T3
T3T3
T3T3
D2
D7 S5
F5
S1 S1
S1S1S1S1
M4 M4
M4M4 M4 M4
D4
D4D4
D4 D4 D4
S4
S3
S3
S2 S2
D1
S2
T1
I-1
I-1
/1 I-112
/1 I-113
F4
F4
D4
S10
S10
S10
S10
S10
M9
M9
F2BF2B
F2
F2
F2BF2B
F7
D2
D3
D2
D2 D3 S1S1
S1
S1 S1
S1 S1
F7 F7
F7F7F7
T5
S2
MECHANICAL
ELECTRICAL
FLIGHT SUPERVISOR
READINESS
FLIGHT COMMANDER
SECTION CHIEF
SIPR
TRAINING B
WOMEN
PLUMBING CHASE
109B
JAN
CORRIDOR
MEN
CENTRAL STORAGE
FUNCTIONAL SYSTEM
MANAGER
102A
RESOURCE ADVISOR
102BM4
RECEPTION/ WAITING
SUPERINTENDENT
102C
FIRST SERGEANT
102D
CLOSET
102G
CORRIDOR
CONFERENCE
VESTIBULE A
100A
DIRECTOR OF OPS
102F
COMMANDER
102E
ORDERLY
CARGO INBOUND
COMM
BREAK ROOM
LACTATION
CORRIDOR
CORRIDOR
CORRIDOR
VESTIBULE B
100B
T7 F7
D4
T2
T8
T8
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
I-111
AD
M
IN
IS
TR
AT
IV
E
AR
EA
F U
R N
IT
U
R E
PL
AN
O
FF
U
TT
A
FB
, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
M . H
U G
H
ES
M . H
U G
H
ES
B.
G
O R
U P
B.
G
O R
U P
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O
VE
R Y
LO
G
IS
TI
C S
R
EA
D
IN
ES
S
SQ
U
AD
R
O N
C
AM
PU
S
O F6
3_
LR
S-
IN
T.
rv t
FURNITURE LEGEND
ITEM CODE ITEM NAME
D1 U-SHAPED DESK
D2 U -SHAPED DESK, WINDOW SIDE
D3 U -SHAPED DESK, WINDOW BACK
D4 WORKSTATION, 6X6
D5 WORKSTATION, RECEPTION
D6 SINGLE DESK
D7 INSTRUCTOR DESK W/ LECTERN
F1 STORAGE CABINET
F2 BENCH W/ STORAGE
F2B LOCKERS
F3 INDUSTRAIL SHELVING, 48X15X76
F4 CREDENZA
F5 LATERAL FILE, 6 DRAWERS
F6 LATERAL FILE, 4 DRAWERS
F7 LOCKER W/ SHELVES
M2 REFRIGERATOR
M3 RECYCLE STATION
M4 TRASH BIN, SMALL
M5 MIRCOWAVE
M6 REFRIGERATOR, UNDERCOUNTER
M7 FLOOR LAMP
M8 MIRCOWAVE, LACTATION RM
M9 TRASH BIN, LARGE
M10 FULL LENGTH MIRROR
S1 DESK CHAIR
S2 GUEST CHAIR
S3 LOUNGE CHAIR
S4 LOUNGE SOFA
S5 TRAINING CHAIR
S6 HEALTH CHAIR
S7 CONFERENCE CHAIR
S8 CONFERENCE GUEST CHAIR
S9 BREAK CHAIR
S10 BREAKROOM STOOL
T1 CONFERENCE TABLE, 48" X 168"
T2 COFFEE TABLE
T3 TRAINING TABLE
T4 BREAK TABLE, HIGH 20" X 60"
T5 BREAK TABLE, 36" X 72"
T6 BREAK TABLE, HIGH 20" X 84"
T7 PULL-UP TABLE
T8 END TABLE
PLAN NORTH
KEY PLAN
WAREHOUSE
SHIPPING /
RECEIVING
ADMIN
8'0 4' 16'
1/8" = 1'-0"1 ADMINISTRATIVE AREA FURNITURE PLAN
FURNITURE GENERAL NOTES
1. FF&E IS A BID OPTION TO THE CONSTRUCTION CONTRACT.
2. SEE FF&E PACKAGE FOR ADDITIONAL INFORMATION.
3. SEE SPECIFICATIONS 12 50 00.13 10 FOR ADDITIONAL
INFORMATION.
4 PRINTER/COPIERS (OR ANY OTHER GF/GI EQUIPMENT) ARE NOT IN
CONTRACT AND SHOWN FOR COORDINATION PURPOSES ONLY.
5 WOODSHOP EQUIPMENT ARE NOT IN CONTRACT AND SHOWN FOR
COORDINATION PURPOSES ONLY.
AM
G
EN
ER
A L
R
EV
I S
IO
N S
-0
1-
F3
F3
M4 S1
D4
F1
F5
S1 S1
S1 M4
M4
M4
M4M4
F3
F2
T4
T6
I-1
/1 I-112/1 I-112
F2 F2B F2B
SHIPPING/ RECEIVING
WOOD SHOP
CARGO OUTBOUND
ELECTRICAL
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
I-113
SH
IP
PI
N
G
R
EC
EI
VI
N G
(S O
U
TH
) A R
EA
FU
R N
IT
U
R E
FL
O
O R
P
LA
N
O
FF
U
TT
A
FB
, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
M . H
U G
H
ES
M . H
U G
H
ES
B.
G
O R
U P
B.
G
O R
U P
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O
VE
R Y
LO
G
IS
TI
C S
R
EA
D
IN
ES
S
SQ
U
AD
R
O N
C
AM
PU
S
O F6
3_
LR
S-
IN
T.
rv t
1/8" = 1'-0"1 SHIPPING / RECEIVING (SOUTH) FURNITURE PLAN
PLAN NORTH
KEY PLAN
WAREHOUSE
SHIPPING /
RECEIVING
ADMIN
8'0 4' 16'
FURNITURE LEGEND
ITEM CODE ITEM NAME
D1 U-SHAPED DESK
D2 U -SHAPED DESK, WINDOW SIDE
D3 U -SHAPED DESK, WINDOW BACK
D4 WORKSTATION, 6X6
D5 WORKSTATION, RECEPTION
D6 SINGLE DESK
D7 INSTRUCTOR DESK W/ LECTERN
F1 STORAGE CABINET
F2 BENCH W/ STORAGE
F2B LOCKERS
F3 INDUSTRAIL SHELVING, 48X15X76
F4 CREDENZA
F5 LATERAL FILE, 6 DRAWERS
F6 LATERAL FILE, 4 DRAWERS
F7 LOCKER W/ SHELVES
M2 REFRIGERATOR
M3 RECYCLE STATION
M4 TRASH BIN, SMALL
M5 MIRCOWAVE
M6 REFRIGERATOR, UNDERCOUNTER
M7 FLOOR LAMP
M8 MIRCOWAVE, LACTATION RM
M9 TRASH BIN, LARGE
M10 FULL LENGTH MIRROR
S1 DESK CHAIR
S2 GUEST CHAIR
S3 LOUNGE CHAIR
S4 LOUNGE SOFA
S5 TRAINING CHAIR
S6 HEALTH CHAIR
S7 CONFERENCE CHAIR
S8 CONFERENCE GUEST CHAIR
S9 BREAK CHAIR
S10 BREAKROOM STOOL
T1 CONFERENCE TABLE, 48" X 168"
T2 COFFEE TABLE
T3 TRAINING TABLE
T4 BREAK TABLE, HIGH 20" X 60"
T5 BREAK TABLE, 36" X 72"
T6 BREAK TABLE, HIGH 20" X 84"
T7 PULL-UP TABLE
T8 END TABLE
AM
G
EN
ER
A L
R
EV
I S
IO
N S
-0
1-
FURNITURE GENERAL NOTES
1. FF&E IS A BID OPTION TO THE CONSTRUCTION CONTRACT.
2. SEE FF&E PACKAGE FOR ADDITIONAL INFORMATION.
3. SEE SPECIFICATIONS 12 50 00.13 10 FOR ADDITIONAL
INFORMATION.
4 PRINTER/COPIERS (OR ANY OTHER GF/GI EQUIPMENT) ARE NOT IN
CONTRACT AND SHOWN FOR COORDINATION PURPOSES ONLY.
5 WOODSHOP EQUIPMENT ARE NOT IN CONTRACT AND SHOWN FOR
COORDINATION PURPOSES ONLY.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
E-401
AR
EA
S
EX
EM
PT
F R
O M
S
EC
TI
O
N
8.
R
EQ
U
IR
EM
EN
TS
O
FF
U T
AF
B, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
K.
P
AV
LI
K
K.
P
AV
LI
K
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O R
Y
LO
G
IS
TI
C
S R
EA
D
IN
ES
S
SQ
U
AD
R O
N C
AM
PU
S
O F6
3_
LR
S-
EL
EC
.rv t
AM
G
EN
ER
A L R
EV
I S
IO
N
S
-0 1-
3/32" = 1'-0"1 AREAS EXEMPT FROM SECTION 26 05 48.00 10 REQUIREMENTS
AREAS EXEMPT FROM SECTION 26 05 48.00 10
REQUIREMENTS LEGEND
1 EXEMPT UNLESS EQUIPMENT IS GAS-FUELED OR ABOVE
EQUIPMENT THAT IS GAS-FUELED.
2 NOT EXEMPT.
PLAN NORTH
0 20'10'5'
KEY PLAN
WAREHOUSE
SHIPPING /
RECEIVING
ADMIN
3/4"x10' GROUND ROD
3/4"x10' GROUND ROD WITH TEST WELL
SUPPLEMENTAL LIGHTNING PROTECTION
AND GROUNDING LEGEND
MGB
GROUND BAR, SEE EG503 FOR SIZE.GB
TMGB
TGB
MAIN GROUND BAR, SEE EG503 FOR SIZE.
TELECOMMUNICATIONS MAIN GROUND BAR, SEE EG503 FOR SIZE.
TELECOMMUNICATIONS GROUND BAR, SEE EG503 FOR SIZE.
LIGHTNING PROTECTION ROOF MAIN CONDUCTORRC
LIGHTNING PROTECTION DOWN CONDUCTORDC
COUNTERPOISE GROUND LOOPG
AIR TERMINAL, 60" MINIMUM HEIGHT
AIR TERMINAL, 24" MINIMUM HEIGHT
AIR TERMINAL, 12" MINIMUM HEIGHT
CGB CONTINUOUS GROUND BAR, SEE EG503 FOR SIZE.
EGB ELECTRICAL GROUND BAR, SEE EG503 FOR SIZE.
AGB ANTENNA GROUND BAR, SEE EG503 FOR SIZE.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
EG001
G R
O U
N D
IN
G
/L
IG
H
TN
IN
G
P R
O
TE
C
TI
O N
SU
PP
LE
M
EN
TA
L
LE
G
EN
D A
N D
N O
TE
S
O
FF
U T
AF
B, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
K.
P
AV
LI
K
K.
P
AV
LI
K
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O R
Y
LO
G
IS
TI
C
S R
EA
D
IN
ES
S
SQ
U
AD
R O
N C
AM
PU
S
O F6
3_
LR
S-
EL
EC
.rv t
GENERAL NOTES - EG100 SERIES SHEETS
1 UNDERGROUND CONDUITS CROSSING FOUNDATIONS SHALL BE BURIED AT A DEPTH SUCH THAT CONDUITS ARE LOCATED MINIMUM 12" BELOW THE
FOUNDATIONS. REFERENCE S-300 SERIES DRAWINGS FOR FOUNDATION DIMENSIONS.
2 THE LIGHTNING PROTECTION SYSTEM DESIGN IS BASED ON THE ROLLING SPHERE DESIGN IS APPROXIMATE, AND IS SUBJECT TO DESIGN VERIFICATION AND
APPROVAL BY CONTRACTOR. ENSURE THAT DURING INSTALLATION ALL POINTS ARE WITHIN 2'-0" OF OUTSIDE BUILDING EDGE, OUTSIDE CORNERS, AND RIDGE ENDS. THE MAXIMUM SPACING OF PERIMETER TERMINALS DOES NOT EXCEED 20'-0" FOR 12" COPPER AIR TERMINALS AND 25'-0" FOR 24" COPPER AIR TERMINALS. SUBMIT INSTALLATION DRAWINGS AND PROVIDE AN UL MASTER LABEL CERTIFIED SYSTEM COORDINATING WITH ACTUAL SUBMITTED MECHANICAL EQUIPMENT, ROOF INFORMATION, AND ROOFING MANUFACTURER REQUIREMENTS. ENSURE MINIMUM AIR TERMINAL PROJECTION ABOVE OBJECTS IS 24".
LOCATE AIR TERMINALS AS SHOWN AT MINIMUM.
3 CONTRACTOR SHALL BOND TO BUILDING STEEL, ELECTRICAL SERVICE, WATER SERVICE, GAS SERVICE, AND OTHER PIPING SYSTEMS AS REQUIRED BY NFPA 70, NFPA 780, AND OTHER APPLICABLE CODES.
4 CONTRACTOR SHALL VERIFY STRUCTURAL MEMBER LOCATIONS.
5 CONTRACTOR SHALL VERIFY MECHANICAL EQUIPMENT LOCATIONS.
6 COORDINATE INSTALLATION OF LOOP CONDUCTOR WITH INCOMING UTILITIES. BARE COPPER COUNTERPOISE SHALL BE INSTALLED AT A MINIMUM DEPTH OF 30
INCHES, BURIED BETWEEN 3' AND 8' AWAY FROM THE BUILDING, AND HAVE NO BENDS LESS THAN 90 DEGREES.
7 COORDINATE DOWN CONDUCTORS WITH ALL INCOMING UTILITIES.
8 CONTRACTOR SHALL PROVIDE CONDUCTOR FROM ROOF CONDUCTOR TO GROUND ROD, ROUTE CONDUCTOR AROUND GUTTER, PARAPET WALL, AND/OR ROOF
EVE AND ALL INCOMING UTILITIES.
9 ALL CONNECTIONS AND EQUIPMENT BONDING SHALL BE IN ACCORDANCE WITH SPECIFICATIONS AND NFPA 780.
10 BOND EXHAUST HOODS AND PIPES TO LIGHTNING PROTECTION CONDUCTOR.
11 CONTRACTOR SHALL PROVIDE 3/4" X 10'-0" COPPER CLAD STEEL GROUND RODS AT MINIMUM LOCATIONS SHOWN. GROUND RODS SHALL BE SPACED EVERY 50'
MAXIMUM.
12 MAINTAIN HORIZONTAL OR DOWNWARD COURSING OF MAIN CONDUCTOR AND ENSURE THAT ALL BENDS HAVE AT LEAST A 8" RADIUS AND DOES NOT EXCEED 90
DEGREES.
13 GROUND BARS TO BE ANCHORED AT INTERVALS NOT TO EXCEED 2'-0".
14 GROUND BARS SHALL BE PRE-DRILLED.
15 AIR TERMINALS SHALL BE BLUNT TIP TYPE.
16 PERIMETER COLUMNS SHALL BE BONDED TO COUNTERPOISE SYSTEM AT INTERVALS NOT EXCEEDING 60 FEET ON AVERAGE FOR BUILDING PERIMETER PER
NFPA 780-2020 SECTION 4.19.4. SIZE SHALL BE AS SHOWN ON EG601.
17 GROUNDING AND BONDING CONDUCTORS SHOULD NOT BE PLACED IN FERROUS METALLIC CONDUIT. IF NECESSARY TO PLACE GROUNDING AND BONDING
CONDUCTORS IN FERROUS METALLIC CONDUIT THAT EXCEEDS 3 FEET IN LENGTH, THE CONDUCTORS SHALL BE BONDED TO EACH END OF THE CONDUIT USING
A GROUNDING BUSHING OR A #6 AWG CONDUCTOR, MINIMUM.
18 EACH TELECOMMUNICATIONS GROUNDING AND BONDING CONDUCTOR SHALL BE LABELED. LABELS SHALL BE LOCATED ON CONDUCTORS AS CLOSE AS PRACTICABLE TO THEIR POINT OF TERMINATION IN A READABLE POSITION. LABELS SHALL BE NONMETALLIC AND SHALL BE IN ACCORDANCE WITH TIA 606. SEE
DETAIL 6/EG503.
19 PENETRATION OPENINGS THROUGH AIR BARRIERS SHALL COMPLY WITH THE BUILDING AIR BARRIER REQUIREMENTS. SEE ARCHITECTURAL SHEETS FOR AIR
BARRIER BOUNDARIES.
20 SUPPORT EXPOSED ROOF CABLES AS SHOWN IN APPLICABLE DETAILS AT 36" ON CENTER MAXIMUM.
21 BOND OBSTRUCTION LIGHTING CONDUIT (IF PRESENT) TO LIGHTNING PROTECTION SYSTEM AT EACH DOWN CONDUCTOR, CROSS CONDUCTOR LOCATION, AND/OR OBSTRUCTION LIGHT LOCATION. BONDING CONDUCTOR SHALL BE THE SAME SIZE AS THE LIGHTNING PROTECTION SYSTEM CONDUCTOR.
22 BOND PROTECTIVE BOLLARDS AROUND BUILDING PERIMETER TO COUNTERPOISE OR GROUNDED COLUMN WITH MINIMUM #6 AWG COPPER.
23 BOND ALL ROOF MOUNTED METALLIC PARTS AND EQUIPMENT TO THE LIGHTNING PROTECTION SYSTEM.
24 REFERENCE GROUNDING RISER ON SHEET EG601 FOR CONDUCTOR SIZES NOT LISTED AND ROUTING NOT SHOWN ON PLANS.
25 ROOF CONDUCTOR DEAD ENDS SHALL NOT EXCEED CONDUCTOR LENGTHS PERMITTED UNDER NFPA 780.
26 NOT ALL ELEMENTS (PARTICULARLY SIDEWALL ELEMENTS, SUCH AS INTAKE AND EXHAUST LOUVERS) ARE IDENTIFIED ON EG SHEETS FOR BONDING.
CONTRACTOR TO FIELD VERIFY LOCATIONS AND BOND ACCORDINGLY.
KEYED NOTES - EG100 SERIES SHEETS
1 SEE DETAIL 1/EG501.
2 SEE DETAIL 2/EG501.
3 APPROXIMATE LOCATION OF DOMESTIC WATER ENTRANCE TO FACILITY. COORDINATE WITH P-100 SERIES SHEETS TO BOND TO BUILDING
COUNTERPOISE SYSTEM.
4 APPROXIMATE LOCATION OF SANITARY SEWER ENTRANCE TO FACILITY. COORDINATE WITH P-100 SERIES SHEETS TO BOND TO BUILDING
COUNTERPOISE SYSTEM.
5 APPROXIMATE LOCATION OF FIRE WATER ENTRANCE TO FACILITY. COORDINATE WITH FX100 SERIES SHEETS TO BOND TO BUILDING
COUNTERPOISE SYSTEM.
6 APPROXIMATE LOCATION OF NATURAL GAS ENTRANCE TO FACILITY. COORDINATE WITH M-100 SERIES SHEETS TO BOND TO BUILDING
COUNTERPOISE SYSTEM.
7 GROUND CONDUCTORS SHALL BE ROUTED IN CONDUIT BETWEEN DEVICES.
8. CONNECT EGB TO MGB. SEE SHEET EG601 FOR SIZE.
9 BOND STRUCTURAL STEEL TO THE COUNTERPOISE SYSTEM.
10 CONCEAL DOWN CONDUCTORS WITHIN THE BUILDING. UTILIZE BUILDING STRUCTURAL STEEL AS THE DOWN CONDUCTOR. REFER TO
1/EG502 .
11 CONCEAL DOWN CONDUCTORS WITHIN THE BUILDING. REFER TO 3/EG502.
AM
G
EN
ER
A L
R
EV
I S
IO
N S
-0
1-
G
G
G G
DC
G
G
G
DC
DC
G
1 2 3 4
A
B
CONFERENCE
100A
DIRECTOR OF
OPS
102F
COMMANDER
102E
FIRST SERGEANT
102D
SUPERINTENDENT
102C
RECEPTION/
WAITING
ORDERLY
CENTRAL
STORAGE
CLOSET
102G
2 9
RESOURCE
ADVISOR
102B
FUNCTIONAL
SYSTEM
MANAGER
102A
1 2 3 4
B
C
MEN
WOMEN
CARGO INBOUND
TOILET
MECHANICAL
100B
ELECTRICAL
COMM
SIPR
BREAK ROOM
LACTATION
READINESS
FLIGHT
SUPERVISOR
SECTION CHIEF
FLIGHT
COMMANDER
TRAINING B
CORRIDOR
MGB
TMGB
PLUMBING CHASE
109B
7 8.
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
EG101
G R
O U
N D
IN
G
P
LA
N
AD
M
IN
A
R
EA
O
FF
U T
AF
B, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
K.
P
AV
LI
K
K.
P
AV
LI
K
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O R
Y
LO
G
IS
TI
C
S R
EA
D
IN
ES
S
SQ
U
AD
R O
N C
AM
PU
S
O F6
3_
LR
S-
EL
EC
.rv t
1/8" = 1'-0"1 GROUNDING PLAN - ADMIN NORTH
1/8" = 1'-0"2 GROUNDING PLAN - ADMIN SOUTH
PLAN NORTH
8'0 4' 16'
KEY PLAN
WAREHOUSE
SHIPPING /
RECEIVING
ADMIN
AM
G
EN
ER
A L
R
EV
I S
IO
N S
-0
1-
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYED NOTES, SEE SHEET EG001.
LIGHT FIXTURE
90° (PLAN NORTH)
180° 0°
270°
LIGHT FIXTURE
(LIGHT FIXTURE AIMING
ANGLE IS SHOWN AT 90°)
90°
0°
(PARALLEL TO GRADE)
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
EL610
LU
M
IN
AI
R E
AI
M
IN
G
S C
H
ED
U
LE
O
FF
U T
AF
B, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
K.
P
AV
LI
K
K.
P
AV
LI
K
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O R
Y
LO
G
IS
TI
C
S R
EA
D
IN
ES
S
SQ
U
AD
R O
N C
AM
PU
S
O F6
3_
LR
S-
EL
EC
.rv t
AM
G
EN
ER
A L R
EV
I S
IO
N
S
-0 1-
FLOODLIGHT AIMING SCHEDULE
LIGHT POLE
IDENTIFICATION
LIGHT FIXTURE
IDENTIFICATION
FIXTURE
SYMBOL
MOUNTING
HEIGHT
ORIENTATION
(DEGREES)
TILT
(DEGREES)
P-1 PL-1 PL 32' 135 0
P-2 PL-2 PL 32' 0 0
P-2 PL-3 PL 32' 90 0
P-2 PL-4 PL 32' 180 0
P-3 PL-5 PL 32' 270 0
N.T.S.1
FLOODLIGHT FIXTURE
HORIZONTAL AIMING DETAIL
N.T.S.2
FLOODLIGHT FIXTURE
VERTICAL AIMING (TILT) DETAIL
J J J J
E
E
E E
E
EE
E
EE
J
J J
E
E
E
E
EEEEE
E
M D
S-
E
E EJ J
J
J
MR
H
-2
MR
H -1
J
JJ
J
J J
J
E E E
DL DL DL
J J J
E
J
E
E
M C
P-
MD
A-
M
UH-7
M
UH-2
M
UH-3
M
UH-4
M
UH-5
M
UH-6
EJ
E
E
DL
J
E
3 4 5 6 7 8 9 10
B
C
SHIPPING/
RECEIVING
122 1
EP400
OHD-122F
CR-1 CR-2 CR-3 CR-4
G,WP
G,WPG,WPG,WPG,WPG,WPG,WP
NLGE-6 NLGE-4
ELECTRICAL
CARGO
OUTBOUND
WOOD SHOP
CDS-2
NLME-11NLME-9
NLME-7
RH-1
+204" AFF
RH-2
+204" AFF
NLGE-57
NLGE-59
W S-
TS
W
S-
AC W
S- D
C
N H
D E-
,2
8, N
LW
-5
NLW-3
NLW-4,6
NLGE-39
7 N
LG
E-
NLGE-51
NLW-2
COPIER
HVLS-2
NLME-21
DDC
TS-1
NLGE-63
N
LM
E-
N
LM
E-
7 7
NLGE-8 NLGE-41
DL-122B DL-122D DL-122G
NLGE-27,29,31
N
LT
-5 ,7
NLW
SPD
NLME-2
HVLS
CTLR
NLME-4
OHD-122GOHD-122D
NLGE-37
OHD-122C
NLGE-35
OHD-122B
NLGE-33
N
LM
E-
,1 5, HVU-1
N H
M -1
9, ,2
HVLS-1
NLGE-9,11,13
NLGE-15,17,19
NLGE-55
NLGE-49
NLGE-12 NLGE-14 NLGE-16 NLGE-18
NLGE-61
NLW-1
N
LG
E-
10 NLGE-2
HVU-1(SP) N
LM
E-
WAP WAP WAP
WS-DC2
NLW-8,10,12
WS-MS
HVU-1
HVU-1(SP)
DL-122F
NLGE-21,23,25
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
EP103
PO
W
ER
P
LA
N
SH
IP
PI
N G
R
EC
EI
VI
N
G A
R
EA
O
FF
U T
AF
B, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
K.
P
AV
LI
K
K.
P
AV
LI
K
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O R
Y
LO
G
IS
TI
C
S R
EA
D
IN
ES
S
SQ
U
AD
R O
N C
AM
PU
S
O F6
3_
LR
S-
EL
EC
.rv t
1/8" = 1'-0"1 POWER PLAN - SHIPPING / RECEIVING
PLAN NORTH
8'0 4' 16'
KEY PLAN
WAREHOUSE
SHIPPING /
RECEIVING
ADMIN
AM
G
EN
ER
A L
R
EV
I S
IO
N S
-0
1-
FOR SUPPLEMENTAL LEGEND, GENERAL NOTES, AND KEYED NOTES, SEE SHEET EP001.
ELECTRICAL SERVICE RESPONSIBILITY TABLE
UTILITY * CONTRACTOR
MEDIUM VOLTAGE:
ALL CABLES AND TERMINATIONS
SERVICE TRANSFORMER
SERVICE TRANSFORMER PAD
LOW VOLTAGE:
TRANSFORMER SECONDARY CONDUCTORS
TRANSFORMER SECONDARY DUCT BANK
UTILITY KWH METER, CT'S, AND WIRING AT TRANSFORMER
KWH METER ENCLOSURE AND CONDUIT
X X
X
X
X
ALL TRENCHES AND CONDUITS
X
X
X
* CONTACT OPPD FOR COORDINATION WITH BASE UTILITY PROVIDER.
POC: DAVID ORTIZ (531-226-3396 / dtortiz@oppd.com).
SERVICE SWITCH
SERVICE SWITCH PAD
X X
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
EP600
O N
E-
LI
N E
D
IA
G R
AM
N
O
TE
S
AN
D S
C H
ED
U
LE
S
O
FF
U T
AF
B, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
K.
P
AV
LI
K
K.
P
AV
LI
K
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O R
Y
LO
G
IS
TI
C
S R
EA
D
IN
ES
S
SQ
U
AD
R O
N C
AM
PU
S
O F6
3_
LR
S-
EL
EC
.rv t
AM
G
EN
ER
A L R
EV
I S
IO
N
S
-0 1-
GENERAL NOTES - EP600-EP609 SHEETS
1 FAULT CURRENT AMP INTERRUPTING CAPACITIES ARE MINIMUM. IF STANDARD EQUIPMENT RATING IS GREATER, PROVIDE STANDARD RATING.
2 PROVIDE FULL LENGTH MINIMUM 100%-RATED NEUTRAL BAR AND A GROUNDING BAR IN EACH SECTION OF THE SWITCHBOARDS AND PANELBOARDS. PROVIDE MAIN BONDING JUMPER IN ACCORDANCE WITH NFPA 70 ARTICLE 250.
3 NOT ALL CIRCUITS ARE SHOWN ON ONE-LINE DIAGRAM. SEE PANEL SCHEDULES, EQUIPMENT CONNECTION SCHEDULE, AND LIGHTING AND POWER PLANS FOR ADDITIONAL INFORMATION.
4 PROVIDE CABLE REDUCING ADAPTERS AS NECESSARY TO ACCOMMODATE CONDUCTORS INCREASED IN SIZE TO MITIGATE VOLTAGE DROP.
5 NOT ALL INFORMATION SHOWN ON THIS DIAGRAM (SPARE CIRCUIT BREAKERS, LOCKABLE BREAKERS, GFI BREAKERS, MCB TRIP RATINGS, ETC.). REFERENCE PANEL SCHEDULES FOR ADDITIONAL INFORMATION.
6 FAULT CURRENTS LISTED ASSUME UTILITY CONTRIBUTION OF 4.1%Z AND 15,000AIC ON THE TRANSFORMER SECONDARY LUGS. CONTRACTOR TO COORDINATE AVAILABLE FAULT CURRENT WITH BASE UTILITY PROVIDER FOR USE WITH 26 28 01.00 10 STUDIES. CONTRACTOR SHALL ADJUST EQUIPMENT SHORT CIRCUIT RATINGS
ACCORDING TO STUDY RESULTS.
KEYED NOTES - EP600-EP609 SHEETS
1 PANELBOARD-MOUNTED BUILDING DIGITAL METER. PROVIDE 24 AWG, SHIELDED, TWISTED, 2 PAIR, RS-485 CABLE IN 1" EMT CONDUIT FROM BUILDING DIGITAL METER TO NEAREST DDC CONTROLLER FOR CONNECTION INTO DDC CONTROL LOOP. ALSO, PROVIDE 24 AWG, SHIELDED, TWISTED, 1 PAIR, RS-485 CABLE IN 1" EMT CONDUIT TO
THE NEAREST ENERGY MONITORING KWHR METER. SEE GENERAL NOTE 3 AND SPECIFICATIONS FOR ADDITIONAL METERING INFORMATION.
2 SEE TRANSFORMER SCHEDULE.
3 SEE PANEL SCHEDULE.
4 SEE ECB SCHEDULE.
5 PROVIDE RED LOCK-ON TYPE CIRCUIT BREAKER. PROVIDE A LABEL WITH THE FOLLOWING INSCRIPTION: "FIRE PROTECTION/LIFE SAFETY EQUIPMENT". CONSTRUCT AND FASTEN THE LABEL IDENTICAL TO THE PANEL NAMEPLATE, EXCEPT THE LABEL MUST BE RED LAMINATED PLASTIC WITH WHITE CENTER CORE.
6 PROVIDE 100%-RATED BUS AND MCB FOR THIS PANEL. MCB SHALL BE PROVIDED WITH GROUND FAULT PROTECTION.
7 SEE EG601 FOR GROUND CONDUCTOR SIZING.
8 SWITCHBOARD- OR PANELBOARD-MOUNTED ENERGY MONITORING KWHR METER. PROVIDE 24 AWG, SHIELDED, TWISTED, 1 PAIR, RS-485 CABLE IN 1" EMT CONDUIT BETWEEN BUILDING DIGITAL METER AND ENERGY MONITORING KWHR METERS. PROVIDE 277V:120V P.T.s AND XXA:5A C.T.s FOR EACH ENERGY MONITORING KWHR METER
WITH XXA = TO NEAREST FULL SCALE READING OF THE CIRCUIT BEING METERED. FOR EXAMPLE, 100A:5A FOR A 100A CIRCUIT, 200A:5A FOR A 200A CIRCUIT, ......ETC. SEE GENERAL NOTE 3 FOR METERING DESIGNATIONS. WHERE METERS ARE SHOWN ON SWITCHBOARDS, METERING EQUIPMENT SHALL BE LOCATED INSIDE THE SWITCHBOARD WITH EXTERNALLY-VISIBLE DISPLAYS. WHERE METERS ARE SHOWN ON PANELBOARDS, METERING EQUIPMENT ARE PERMITTED TO BE LOCATED IMMEDIATELY ADJACENT TO THE PANEL.
9 PROVIDE A LABEL WITH THE FOLLOWING INSCRIPTION: "FIRE PROTECTION/LIFE SAFETY EQUIPMENT". LABEL SHALL BE RED LAMINATED PLASTIC WITH WHITE CENTER CORE.
10 SPARE DEDICATED FOR FUTURE NORTHERN EXPANSION.
11 CIRCUITS ARE ASSUMED TO BE ROUTED UNDERGROUND OR IN A SPACE WHERE THE AMBIENT TEMPERATURE DOES NOT EXCEED 30°C (86°F) FOR GREATER THAN THE DISTANCE IDENTIFIED IN THE NFPA 70 SECTION 310.15(A)(2) EXCEPTION. THE CIRCUITS ARE ALSO ASSUMED TO HAVE A ROUTING PATH NOT REQUIRING A SEALOFF DUE
TO HAZARDOUS ZONE. SHOULD THE CONDUCTOR ROUTING LENGTH IN EXCESS OF THIS DISTANCE IN AN ENVIRONMENT EXCEEDING 30°C (86°F) OR TAKE A PATH REQUIRING A SEALOFF, THE CONTRACTOR SHALL CONSULT THE COR FOR NEW CONDUCTOR AND CONDUIT SIZES AND INSTALL THE NEW SIZE AT NO ADDITIONAL COST TO THE
GOVERNMENT.
12 SEE EG601 FOR ADDITIONAL CONNECTIONS.
ELECTRICAL METER DESIGNATIONS
ABBR. DESCRIPTION
# SPARE LOADS, TYPE TO BE PROGRAMMED LATER (PROGRAM AS 'O' IN INITIAL INSTALLATION).
F FIRE ALARM/RELEASING SERVICES/MNS/PA LOADS
G PROCESS/PLUG LOADS
H HVAC LOADS
L INTERIOR LIGHTING LOADS
M MAIN METER
O OTHER LOADS
T TELECOMMUNICATIONS LOADS
X EXTERIOR LIGHTING LOADS
TRANSFORMER SCHEDULE GENERAL NOTES
1 CONTRACTOR SHALL SIZE THE TRANSFORMER OVERCURRENT PROTECTION (INCLUDING DEVICE FRAME) PER SPECIFICATION 26 28 01.00 10 RECOMMENDATIONS AT NO ADDITIONAL COST TO THE GOVERNMENT.
2 BOND TRANSFORMER TO BUILDING STEEL WITH GROUNDING ELECTRODE SHOWN IN SCHEDULE.
3 WHERE FEEDERS HAVE BEEN INCREASED IN SIZE TO ACCOUNT FOR VOLTAGE DROP AND/OR AMPACITY CORRECTION FACTORS TO THE DEGREE THAT THE FEEDERS ARE LARGER THAN THE EQUIPMENT TERMINALS, PROVIDE APPROPRIATELY-SIZED CABLE REDUCING ADAPTERS.
4 TRANSFORMER SCHEDULE DOES NOT INCLUDE DRIVE ISOLATION TRANSFORMERS.
5 ENCLOSURE RATINGS LISTED ARE MINIMUM RATINGS WITH RESPECT TO DUST AND LIQUID INGRESS.
OIL-FILLED TRANSFORMER SCHEDULE
TAG
SIZE
(kVA) LOCATION
PRIMARY SECONDARY
MOUNTING
LOCATION
ENCLOSURE
RATING
(MINIMUM) REMARKSSYSTEM AMPS OCP CIRCUIT MCIT CCC ATZ
CKT
NOTES SYSTEM AMPS CIRCUIT(S) MCIT CCC NLL ATZ
CKT
NOTES
MIN. GND
ELECTRODE
SERVICE
XFMR
500 SEE SITE PLAN 13800V 23 A BY OPPD CONDUCTORS BY OPPD
CONDUIT BY THIS CONTRACT
-- -- -- -- 480Y/277V 601 A 2 SETS [4-350KCMIL, 3-1/2"C] 90 3 No 2^ -- 2/0 GROUND NEMA 3R
DRY-TYPE TRANSFORMER SCHEDULE
TAG
SIZE
(kVA) LOCATION
SUPPLY
FROM
PRIMARY SECONDARY
MOUNTING LOCATION
ENCLOSURE
RATING
(MINIMUM)
HARMONIC
TREATMENT REMARKSVOLTS AMPS SYSTEM AMPS CIRCUIT MCIT CCC NLL ATZ
CKT
NOTES
MIN. GND
ELECTRODE
SYS. BOND.
JUMPER
NTF 15 ELECTRICAL 118 NHDW 480V 18 A 208Y/120V 42 A 4-#4, #8 SSBJ, 1-1/4"C 75 4 Yes 0 -- #8 #8 WALL/ELEVATED NEMA 1 K-1
NTGE 75 ELECTRICAL 126 NHDE 480V 90 A 208Y/120V 208 A 4-400KCMIL, 1/0 SSBJ, 3-1/2"C 75 4 Yes 0 -- 1/0 1/0 FLOOR/CONCRETE PAD NEMA 1 K-1 NTGW 75 ELECTRICAL 118 NHDW 480V 90 A 208Y/120V 208 A 4-400KCMIL, 1/0 SSBJ, 3-1/2"C 75 4 Yes 0 -- 1/0 1/0 FLOOR/CONCRETE PAD NEMA 1 K-1 NTME 30 ELECTRICAL 126 NHDE 480V 36 A 208Y/120V 83 A 4-#1, #6 SSBJ, 2"C 75 3 No 0 -- #6 #6 WALL/ELEVATED NEMA 1 K-1 NTMW 30 ELECTRICAL 118 NHDW 480V 36 A 208Y/120V 83 A 4-#1, #6 SSBJ, 2"C 75 3 No 0 -- #4 #4 WALL/ELEVATED NEMA 1 K-1
NTT 30 ELECTRICAL 118 NHDW 480V 36 A 208Y/120V 83 A 3-#1, 4/0 N, #6 SSBJ, 2"C 75 4 Yes 0 -- #6 #6 FLOOR/CONCRETE PAD NEMA 1 K-4 NTW 30 ELECTRICAL 126 NHDE 480V 36 A 208Y/120V 83 A 4-#1, #6 SSBJ, 2"C 75 4 Yes 0 -- #6 #6 FLOOR/CONCRETE PAD NEMA 1 K-1
ENCLOSED CIRCUIT BREAKER SCHEDULE
NAME LOCATION SUPPLY FROM VOLTS
EQUIPMENT PROPERTIES DOWNSTREAM CIRCUIT PROPERTIES
CKT
NOTES REMARKSENCLOSURE
FAULT
DUTY (MIN.)
EQPT
FRAME
CB
RATING METER
CB
SVC SSCB CIRCUIT MCIT CCC NLL ATZ
ECB-NLMW ELECTRICAL 118 118 XFMR NTMW 208 V NEMA 1 10kAIC 100 A 100 A No Std Yes 4-#1, #8 G, 2"C 75 3 No 2 -- ECB-NLT ELECTRICAL 118 118 XFMR NTT 208 V NEMA 1 10kAIC 100 A 100 A No Std Yes 3-#1, 4/0 N, #8 G, 2"C 75 4 Yes 0 -- ECB-NLW ELECTRICAL 126 126 XFMR NTW 480 V NEMA 1 10kAIC 100 A 100 A No Std Yes 4-#1, #8 G, 2"C 75 4 Yes 0 --
ENCLOSED CIRCUIT BREAKER NOTES
1. SEE "PANEL SCHEDULE KEY" FOR HEADINGS DEFINITIONS, INSTRUCTIONS, AND NOTES.
2. SEE "ELECTRICAL PANEL/SWITCHBOARD/TRANSFORMER SCHEDULE CIRCUIT NOTES" FOR "CKT NOTES".
3. WHERE NEUTRAL CONDUCTOR IS PROVIDED, THE NEUTRAL SHALL BE SWITCHED.
DM
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
EP611
EQ
U
IP
M
EN
T
C O
N N
EC
TI
O N
S C
H
ED
U
LE
O
FF
U T
AF
B, N
EB
R
AS
KA
O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
E.
O
M
AH
A, N
E
K.
P
AV
LI
K
K.
P
AV
LI
K
S.
L
IN
D
G R
EN
S.
L
IN
D
G R
EN
/2
7/
W
F-
-R
-0
W
8-
XX
-X
-X
XX
X
AF
2-
-0
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
O
FF
U
TT
F
LO
O D
R
EC
O R
Y
LO
G
IS
TI
C
S R
EA
D
IN
ES
S
SQ
U
AD
R O
N C
AM
PU
S
O F6
3_
LR
S-
EL
EC
.rv t
C O
N
TR
AC
TO
R F
U R
N
IS
H
ED
AM
G
EN
ER
A L
R
EV
I S
IO
N S
-0
1-
EQUIPMENT ELECTRICAL CONNECTION SCHEDULE - CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
E.Q. I.D. TAG DESCRIPTION LOCATION VOLTS PH HP FLA MCA
PKG
UNIT
NEMA
ENCL.
DISCONNECT STARTER
PNL-CKT
COORDINATING DOCUMENTS
REMARKS BASIS OF DESIGNTYPE SIZE FUSE TYPE SIZE SPECIFICATION(S) SHEET(S)
ACCU-1 AIR COOLED CONDENSING UNIT EXTERIOR NEAR 116 FLIGHT COMMANDER 480 V 3 10 HP 17.6 A 22.0 A Yes 3R SPST 30 A F -- -- NHM-8,10,12 23 81 00 M-602 NOTES 6 AND 12. MITSUBISHI TUHYP144 AHU-1 (1) AIR HANDLING UNIT CIRCUIT 1: SUPPLY FAN MOTOR 120 MECHANICAL 480 V 3 5 HP 7.6 A 9.5 A Yes 1 CB -- -- VFD -- NHM-1,3,5 23 30 00 M-601 NOTE 7. TRANE PERFORMANCE CLIMATE CHANGER AIR HANDLER CSAA SIZE 008 AHU-1 (2) AIR HANDLING UNIT CIRCUIT 2: EXHAUST FAN MOTOR 120 MECHANICAL 480 V 3 3 HP 4.8 A 6.0 A Yes 1 CB -- -- VFD -- NHM-7,9,11 23 30 00 M-601 NOTE 7. TRANE PERFORMANCE CLIMATE CHANGER AIR HANDLER CSAA SIZE 008 B-1 BOILER 120 MECHANICAL 120 V 1 -- 3.3 A 4.2 A Yes 1 SM -- -- -- -- NLMW-10 23 52 00 M-602 LOCHINVAR KNIGHT KHB199 CDS-1 DUCTLESS SPLIT SYSTEM CONDENSOR EXTERIOR NEAR 114 FLIGHT SUPERVISOR 208 V 1 -- 12.4 A 13.0 A Yes 3R SPST 30 A -- -- -- NLMW-20,22 23 81 00 M-601 SUPPLIES POWER TO DS-1. NOTE 6. MITSUBISHI MR SLIM MUZ-GL12NA-U1 CDS-2 DUCTLESS SPLIT SYSTEM CONDENSOR 122 SHIPPING / RECEIVING 208 V 1 -- 12.4 A 13.0 A Yes 1 SPST 30 A -- -- -- NLT-5,7 23 81 00 M-601 SUPPLIES POWER TO DS-2. MITSUBISHI MR SLIM MUZ-GL12NA-U1 CDS-3 DUCTLESS SPLIT SYSTEM CONDENSOR 121 WAREHOUSE 208 V 1 -- 12.4 A 13.0 A Yes 1 SPST 30 A -- -- -- NLME-10,12 23 81 00 M-601 SUPPLIES POWER TO DS-3. MITSUBISHI MR SLIM MUZ-GL12NA-U1 CDS-4 DUCTLESS SPLIT SYSTEM CONDENSOR 121 WAREHOUSE 208 V 1 -- 12.4 A 13.0 A Yes 1 SPST 30 A -- -- -- NLME-6,8 23 81 00 M-601 SUPPLIES POWER TO DS-4. MITSUBISHI PEAD/PUZ-A18 CH-1 CABINET HEATER 100B VESTIBULE 208 V 1 -- 11.5 A 14.4 A Yes 1 SM(2P) -- -- -- -- NLMW-7,9 23 30 00 M-603 TRANE FFJ0202 CH-2 CABINET HEATER 100A VESTIBULE 208 V 1 -- 11.5 A 14.4 A Yes 1 SM(2P) -- -- -- -- NLMW-11,13 23 30 00 M-603 TRANE FFJ0202 CP-1 CONDENSATE PUMP 118 ELECTRICAL 208 V 1 -- 0.1 A 0.2 A Yes 1 SM(2P) -- -- -- -- NLMW-20,22 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-3. NOTE 5. SAUERMANN Si-30 MINI CONDENSATE REMOVAL PUMP CP-2 CONDENSATE PUMP 117 COMM 208 V 1 -- 0.1 A 0.2 A Yes 1 SM(2P) -- -- -- -- NLT-5,7 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-3. NOTE 5. SAUERMANN Si-30 MINI CONDENSATE REMOVAL PUMP CP-3 CONDENSATE PUMP 126 ELECTRICAL 208 V 1 -- 0.1 A 0.2 A Yes 1 SM(2P) -- -- -- -- NLME-10,12 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-3. NOTE 5. SAUERMANN Si-30 MINI CONDENSATE REMOVAL PUMP CP-4 CONDENSATE PUMP 125 CARGO OUTBOUND 208 V 1 -- 0.1 A 0.2 A Yes 1 SM(2P) -- -- -- -- NLME-6,8 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-3. NOTE 5. SAUERMANN Si-30 MINI CONDENSATE REMOVAL PUMP DA-1 EXHAUST FAN INTAKE DAMPER ACTUATOR 120 MECHANICAL 120 V 1 -- 0.5 A 0.6 A Yes 1 SM -- -- -- -- NLMW-2 23 09 13 -- JOHNSON CONTROLS M9220 BAx DA-2 DAMPER ACTUATOR (NORMAL) 120 MECHANICAL 120 V 1 -- 0.5 A 0.6 A Yes 1 SM -- -- -- -- NLMW-2 23 09 13 -- JOHNSON CONTROLS M9220 BAx DA-3 DAMPER ACTUATOR (NORMAL) 109B PLUMBING CHASE 120 V 1 -- 0.5 A 0.6 A Yes 1 SM -- -- -- -- NLMW-1 23 09 13 -- JOHNSON CONTROLS M9220 BAx DA-4 EXHAUST FAN INTAKE DAMPER ACTUATOR 120 MECHANICAL 120 V 1 -- 0.5 A 0.6 A Yes 1 SM -- -- -- -- NLMW-2 23 09 13 -- JOHNSON CONTROLS M9220 BAx DA-5 EXHAUST FAN INTAKE DAMPER ACTUATOR 120 MECHANICAL 120 V 1 -- 0.5 A 0.6 A Yes 1 SM -- -- -- -- NLMW-2 23 09 13 -- JOHNSON CONTROLS M9220 BAx DA-6 EXHAUST FAN INTAKE DAMPER ACTUATOR 125 CARGO OUTBOUND 120 V 1 -- 0.5 A 0.6 A Yes 1 SM -- -- -- -- NLME-2 23 09 13 -- JOHNSON CONTROLS M9220 BAx DL-122B DOCK LEVELER 122 SHIPPING / RECEIVING PLATFORM 208 V 3 1 1/4 HP 3.2 A 4.1 A Yes 3R SPST 30 A -- -- -- NLGE-9,11,13 11 13 19.13 -- NOTES 2 AND 8. MCGUIRE AUTODOL H SERIES DL-122D DOCK LEVELER 122 SHIPPING / RECEIVING PLATFORM 208 V 3 1 1/4 HP 3.2 A 4.1 A Yes 3R SPST 30 A -- -- -- NLGE-15,17,19 11 13 19.13 -- NOTES 2 AND 8. MCGUIRE AUTODOL H SERIES DL-122F EDGE DOCK LEVELER 122 SHIPPING / RECEIVING PLATFORM 208 V 3 1 HP 3.2 A 4.1 A Yes 3R SPST 30 A -- -- -- NLGE-21,23,25 11 13 19.13 -- NOTES 2 AND 8. MCGUIRE AUTODOL HED SERIES DL-122G DOCK LEVELER 122 SHIPPING / RECEIVING PLATFORM 208 V 3 1 1/4 HP 3.2 A 4.1 A Yes 3R SPST 30 A -- -- -- NLGE-27,29,31 11 13 19.13 -- NOTES 2 AND 8. MCGUIRE AUTODOL H SERIES DS-1 DUCTLESS SPLIT SYSTEM 118 ELECTRICAL 208 V 1 -- 0.8 A 1.0 A Yes 1 SM(2P) -- -- -- -- NLMW-20,22 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-1. NOTE 5. MITSUBISHI MR SLIM MSZ-GL12NA-U1 DS-2 DUCTLESS SPLIT SYSTEM 117 COMM 208 V 1 -- 0.8 A 1.0 A Yes 1 SM(2P) -- -- -- -- NLT-5,7 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-2. NOTE 5. MITSUBISHI MR SLIM MSZ-GL12NA-U1 DS-3 DUCTLESS SPLIT SYSTEM 126 ELECTRICAL 208 V 1 -- 0.8 A 1.0 A Yes 1 SM(2P) -- -- -- -- NLME-10,12 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-3. NOTE 5. MITSUBISHI MR SLIM MSZ-GL12NA-U1 DS-4 DUCTLESS SPLIT SYSTEM 125 CARGO OUTBOUND 208 V 1 -- 1.6 A 2.0 A Yes 1 SM(2P) -- -- -- -- NLME-6,8 23 81 00 M-601 SUPPLY CIRCUIT FROM CDS-4. NOTE 5. MITSUBISHI PEAD/PUZ-A18 EF-1 EXHAUST FAN ROOF ABOVE 120 MECHANICAL 120 V 1 1/4 HP 5.8 A 7.3 A No 3R SPST 30 A -- FNVR 00 NLMW-4 23 30 00 M-601 NOTE 6. GREENHECK CUE-141-VG EF-2 EXHAUST FAN ROOF ABOVE 109B PLUMBING CHASE 120 V 1 1/40 HP 0.2 A 0.2 A No 3R SPST 30 A -- FNVR 00 NLMW-3 23 30 00 M-601 NOTE 6. GREENHECK CUE-090-E EWC-1 ELECTRIC WATER COOLER 100 CORRIDOR 120 V 1 -- 6.0 A 7.5 A Yes 1 REC -- -- -- -- NLGW-31 22 00 00 P-601 ELKAY EZSTL8WSLK FLC-1 FORKLIFT CHARGER 121 WAREHOUSE 480 V 3 -- 22.0 A 27.5 A Yes 1 SPST 30 A F -- -- NHDE-25,27,29 26 20 00 -- ECLIPSE II PLUS OPPORTUNITY BATTERY CHARGER (UP TO 22A INPUT) FLC-2 FORKLIFT CHARGER 121 WAREHOUSE 480 V 3 -- 22.0 A 27.5 A Yes 1 SPST 30 A F -- -- NHDE-31,33,35 26 20 00 -- ECLIPSE II PLUS OPPORTUNITY BATTERY CHARGER (UP TO 22A INPUT) FLC-3 FORKLIFT CHARGER 121 WAREHOUSE 480 V 3 -- 22.0 A 27.5 A Yes 1 SPST 30 A F -- -- NHDE-37,39,41 26 20 00 -- ECLIPSE II PLUS OPPORTUNITY BATTERY CHARGER (UP TO 22A INPUT) GFT-1 GLYCOL FEEDER 120 MECHANICAL 120 V 1 1/3 HP 7.2 A 9.0 A Yes 1 REC -- -- -- -- NLMW-12 23 25 00 M-502
M-602
NEMA 5-15. NEPTUNE G-50-1A
GWH-1 GAS WATER HEATER 120 MECHANICAL 120 V 1 -- 2.5 A 3.1 A Yes 1 REC -- -- -- -- NLMW-18 22 00 00 P-601 NEMA 5-15. LOCHINVAR SHIELD SNR126-065 HD-1 HAND DRYER 107 MEN 120 V 1 -- 12.2 A 15.3 A Yes 1 CB -- -- -- -- NLGW-25 10 28 13 -- NOTE 2. LOCKABLE CB IAW NFPA 70 §422.31. XLERATOR 20XLT0948 HD-2 HAND DRYER 107 MEN 120 V 1 -- 12.2 A 15.3 A Yes 1 CB -- -- -- -- NLGW-27 10 28 13 -- NOTE 2. LOCKABLE CB IAW NFPA 70 §422.31. XLERATOR 20XLT0948 HD-3 HAND DRYER 111 WOMEN 120 V 1 -- 12.2 A 15.3 A Yes 1 CB -- -- -- -- NLGW-35 10 28 13 -- NOTE 2. LOCKABLE CB IAW NFPA 70 §422.31. XLERATOR 20XLT0948 HD-4 HAND DRYER 123 TOILET 120 V 1 -- 12.2 A 15.3 A Yes 1 CB -- -- -- -- NLGW-39 10 28 13 -- NOTE 2. LOCKABLE CB IAW NFPA 70 §422.31. XLERATOR 20XLT0948 HVLS-1 HIGH VOLUME LOW SPEED FAN 122 SHIPPING / RECEIVING 480 V 3 1 HP 4.3 A 5.4 A Yes 1 SPST 30 A -- -- -- NHM-13,15,17 23 30 00 M-602 NOTE 8. MACROAIR MY18-0100-MA HVLS-2 HIGH VOLUME LOW SPEED FAN 122 SHIPPING / RECEIVING 480 V 3 1 HP 4.3 A 5.4 A Yes 1 SPST 30 A -- -- -- NHM-19,21,23 23 30 00 M-602 NOTE 8. MACROAIR MY18-0100-MA HVU-1 HEATING AND VENTILATION UNIT 122 SHIPPING / RECEIVING 208 V 3 7.5 HP 21.1 A 28.8 A Yes 1 SPST 60 A -- VFD -- NLME-13,15,17 23 30 00 M-601 NOTES 2, 3, AND 11. RUPP AIR R2-IBT-300-20D HVU-1(SP) HEATING AND VENTILATION UNIT 122 SHIPPING / RECEIVING 120 V 1 -- 8.3 A 10.5 A Yes 1 SPST 30 A -- -- -- NLME-19 23 30 00 M-601 NOTES 2 AND 13. RUPP AIR R2-IBT-300-20D HWP-1 HOT WATER PUMP 120 MECHANICAL 480 V 3 3/4 HP 1.6 A 2.0 A No 1 SPST 30 A -- FVNR 00 NHM-2,4,6 23 52 00 M-602 BELL & GOSSETT E-90 M2(115) REFRIGERATOR 115 BREAK ROOM 120 V 1 -- 15.0 A 18.8 A Yes 1 REC -- -- -- -- NLGW-18 FF&E -- GE PFE28KSKSS M5(115) MICROWAVE 115 BREAK ROOM 120 V 1 -- 14.5 A 18.1 A Yes 1 REC -- -- -- -- NLGW-20 FF&E -- GE JES1657SMSS M6(113) REFRIGERATOR (UNDER COUNTER) 113 LACTATION 120 V 1 -- 8.2 A 10.3 A Yes 1 REC -- -- -- -- NLGW-10 FF&E -- GE GDE03GLKLB M8(113) MICROWAVE 113 LACTATION 120 V 1 -- 9.3 A 11.6 A Yes 1 REC -- -- -- -- NLGW-8 FF&E -- GE JEM3072SHSS OHD-122B OVERHEAD DOOR 122B 122 SHIPPING / RECEIVING 120 V 1 3/4 HP 13.8 A 17.3 A Yes 1 SPST 30 A -- -- -- NLGE-33 08 36 13 -- NOTE 8. SECTION 08 36 13 OHD-122C OVERHEAD DOOR 122C 122 SHIPPING / RECEIVING 120 V 1 3/4 HP 13.8 A 17.3 A Yes 1 SPST 30 A -- -- -- NLGE-35 08 36 13 -- NOTE 8.