Am_0006-Drawings.pdf
PDF 9 MB Posted
- Solicitation number
- W9128F21R0024
About this file
This document package includes architectural and mechanical drawings for the construction of a B-21 Low-Observable Restoration Facility at Ellsworth Air Force Base in South Dakota. Key details include the construction of a new two-bay hangar facility, government trailer complex, and associated site utilities to support aircraft maintenance and restoration. The project involves sitework including grading, paving, and utility extensions. Interior work includes a secure office, locker rooms, training rooms, shops, and mechanical/electrical spaces. HVAC plans show air handling equipment, ductwork, piping, controls and equipment connections. Electrical drawings provide panel schedules and details. The solicitation number is W9128F21R0024 and is being conducted by the Department of the Army Corps of Engineers Omaha District.
View the file
Other files
Show all 45
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
L01 - 06
FINISH
FLOOR LEVEL
S E
E S
C H
E D
U L E
S
IL
L H
E
IG
H T
H E
IG
H
T
SEE SCHEDULE
WIDTH
S E
E S
C H
E D
U
LE
12"
1"
SEE SCHEDULE
WIDTH
H E
IG
H
T
S E
S C
H E
D U
LE
L07
LOUVER SUPPORT
VERTICAL LOUVER MULLION
PREFINISHED ALUMINUM
LOUVER
FASTENER
METAL LOUVER.
ALIGN W/ FACE OF
MTL. PANEL
INSULATED METAL
WALL PANEL
CONTINUOUS SHEET
METAL FLASHING IN BED
OF CONT .SEALANT.
SUPPORT ANGLE BY LOUVER
SUPPLIER AT PERIMETER OF
OPENINGS - FASTEN TO
STRUCTURE AND LOUVER TYP.
COL
L O
U V
E R
H E
IG
H
T
BIRD SCREEN
STRUCTURAL STEEL GIRT
RE: STRUCTURAL
FRAME WIDTH
METAL FLASHING
MTL. PANEL
CLOSURE PROFILE
(2) ROWS OF SEALANT
(2) ROWS OF SEALANT
CONTINUOUS SEALANT
CONTINUOUS METAL
CLEAT & SEALANT
FROM GRID TO FACE OF GIRT
1' - 4" OR 2' - 0"
A
LI
G N
SUPPORT ANGLE BY
LOUVER SUPPLIER AT
PERIMETER OF OPENINGS -
FASTEN TO STRUCTURE
AND LOUVER TYP.
METAL LOUVER
CONT. SEALANT
INSULATED METAL
WALL PANEL
COL
FROM GRID TO FACE OF GIRT
1' - 4" OR 2' - 0"
L O
U V
E R
W
ID
T H
BIRD SCREEN
STEEL CHANNEL
RE: STRUCTURALMETAL WALL PANEL
STANDARD TRIM
A
LI
G N
METAL LOUVER
METAL WALL
PANEL
PREFINISHED METAL
FLASHING IN CONT.
BED OF SEALANT
SUPPORT ANGLE BY
LOUVER SUPPLIER AT
PERIMETER OF OPENINGS -
FASTEN TO STRUCTURE
AND LOUVER TYP.
COL
L O
U V
E R
H E
IG
H
T
BIRD SCREEN
STRUCTURAL STEEL GIRT
RE: STRUCTURAL
CONTINUOUS SEALANT
MANUFACTURER
STANDARD END
TRIM W/ WEEPS
CONT. SEALANT
(2) ROWS OF SEALANT
(2) ROWS OF SEALANT
FROM GRID TO FACE OF GIRT
1' - 4" OR 2' - 0"
A
LI
G N
METAL LOUVER
METAL WALL
PANEL
PREFINISHED METAL
FLASHING IN CONT.
BED OF SEALANT
SUPPORT ANGLE BY LOUVER
SUPPLIER AT PERIMETER OF
OPENINGS - FASTEN TO STRUCTURE
AND LOUVER TYP.
L O
U V
E R
H E
IG
H
T
BIRD SCREEN
STRUCTURAL STEEL GIRT
RE: STRUCTURAL
MANUFACTURER
STANDARD END
TRIM W/ WEEPS
CONT. SEALANT
(2) ROWS OF SEALANT
(2) ROWS OF SEALANT
FROM GRID TO FACE OF BENT PLATE
1' - 4"
STEEL BENT PLATE
RE: STRUCTURAL
A L
IG
N
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R
K
A N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
A M
A S
H E
K E
L
A F
D R
A W
IN
G
C O
D E
E L L S
W O
R T
H A
IR
F
O R
C E
B A
S E
S
D
P N
F X
B M
F
Y
B -2
L
O W
O B
S E
R V
A B
L E
-B
A Y
R E
S T
O R
A T
IO
N
F A
C
IL
IT
Y
A P
R
IL
A D
V E
R T
IS
E
M E
N T
D
E S
IG
N
W F
-2 -R
-0
A-671
L O
U V
E R
S C
H E
D U
L E
T
Y P
E S
A
N D
D E
T A
IL
S
T .K
IM
J .C
O B
L E
R
P .W
A L T
E R
S
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
LOUVER SCHEDULE
QUANTITY TYPE
SIZE HEAD
HEIGHT
SILL
HEIGHT
DETAILS
REMARKSWIDTH HEIGHT HEAD JAMB SILL
6 L01 10' - 2" 6' - 10" 47' - 3" 40' - 5" K1 / A-671 A1 / A-671 F1 / A-671
4 L02 9' - 2" 4' - 2" 37' - 9" 33' - 7" K1 / A-671 A1 / A-671 F1 / A-671
2 L03 8' - 2" 2' - 10" 37' - 8" 34' - 10" K1 / A-671 A1 / A-671 F1 / A-671
1 L04 7' - 2" 2' - 10" 17' - 10" 15' - 0" K1 / A-671 A1 / A-671 F1 / A-671
4 L05 3' - 2" 2' - 10" 17' - 10" 15' - 0" K1 / A-671 A1 / A-671 F1 / A-671
2 L06 13' - 2" 2' - 10" 17' - 10" 15' - 0" K1 / A-671 A1 / A-671 F1 / A-671
1 L07 30' - 0" 9' - 6" 22' - 2" 12' - 8" K8 / A-671 A1 / A-671 F1 / A-671
SCALE: 3" = 1'-0"
A8
LOUVER DETAIL - VERTICAL MULLION
0 3" 6" 9"
SCALE: 3" = 1'-0"F1
LOUVER SILL DETAIL
SCALE: 3" = 1'-0"
A1
LOUVER JAMB DETAIL
SCALE: 3" = 1'-0"K1
LOUVER HEAD DETAIL
VARIES
SCALE: 3" = 1'-0"K8
LOUVER HEAD DETAIL
0 3" 6" 9"
A
M -0
D
E S
IG
N
I S
S U
E D
F O
R P
R
IC
IN
G
A P
R
A
M E
N D
M E
N T
M A
Y
VARIES
GENERAL SHEET NOTES:
REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING DRAWINGS,
FLOOR FINISH DRAWINGS, WALL FINISH DRAWINGS, ENLARGED PLAN
DRAWINGS AND INTERIOR DETAIL DRAWINGS FOR ADDITIONAL FINISH
PLACEMENT INFORMATION.
REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS,
STRUCTURAL DRAWINGS AND COMMUNICATION DRAWINGS FOR
COORDINATION OF BUILDING FINISHES TO BUILDING SYSTEMS.
REFER TO FLOOR FINISH DRAWINGS FOR PLACEMENT OF FLOOR
FINISHES, FLOOR PATTERNS AND FLOOR MATERIAL CHANGES. REFER TO
FLOORING TRANSITION DETAILS FOR TRANSITIONS BETWEEN ADJOINING
FLOORING MATERIALS.
REFER TO WALL FINISH DRAWINGS AND INTERIOR ELEVATIONS FOR
WALL FINISH EXTENTS, CORNER GUARD LOCATIONS, SIGNAGE, AND
SPECIALTY WALL FINISH LOCATIONS.
REFER TO REFLECTED CEILING DRAWINGS FOR CEILING HEIGHTS AND
CEILING MATERIAL EXTENTS.
REFER TO ENLARGED TOILET DRAWINGS, WALL FINISH PLANS AND
INTERIOR ELEVATIONS FOR PLACEMENT OF INTERIOR FINISHES IN
TOILET/LOCKER ROOMS.
REFER TO STAIR DETAILS FOR TYPICAL STAIR FINISH ASSIGNMENT.
REFER TO MILLWORK DETAIL DRAWINGS AND INTERIOR ELEVATIONS
FOR ASSIGNMENT OF SOLID SURFACE AND PLASTIC LAMINATE FINISHES
AND ADDITIONAL INFORMATION.
PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL MOUNTED
ITEMS INCLUDING TOILET FIXTURES, TOILET ACCESSORIES, TOILET
PARTITIONS, MILLWORK, COUNTERTOP SUPPORTS, MARKERBOARDS,
TACKBOARDS, FLAT PANEL DISPLAYS, ACOUSTICAL WALL PANELS, AND
ANY OTHER WALL MOUNTED OBJECT.
UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL STEEL TO BE
PAINTED TO MATCH ADJACENT WALL OR CEILING SURFACE.
ALL METAL FABRICATIONS, HANDRAILS, LADDERS, GUARDRAILS, DOORS,
AND FRAMES TO BE PA-5. MAN DOORS IN HANGAR DOOR TO MATCH
HANGAR DOOR.
ALUMINUM STOREFRONT DOORS AND ALUMINUM WINDOWS TO BE
CLEAR ANODIZED ALUMINUM FINISH.
INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
NO FINISHES REQUIRED ON CONCRETE WALLS OR CONCRETE CEILINGS
UNLESS NOTED OTHERWISE.
ALL EXPOSED CONCRETE FLOORS MUST BE SEALED, UNLESS NOTED
OTHERWISE.
REFER TO SPECIFICATION FOR CORNER GUARD HEIGHTS AND
INSTALLATION METHOD.
AT GYPSUM BOARD SOFFITS AND BULKHEADS, PAINT ALL EXPOSED
SURFACES.
PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS, MISCELLANEOUS
STEEL, PIPING, HANGERS, VALVES AND CONDUITS EXCEPT PRE-
FINISHED LINER PANELS AND FOAM GENERATORS. THE PAINT COLOR IS
TO MATCH ADJACENT WALL OR CEILING COLOR. ALL FIRE PROTECTION
PIPING COLOR MUST BE SAFETY RED.
ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND
ASSOCIATED SUPPORTING EQUIPMENT TO BE PAINTED TO MATCH
ADJACENT WALL OR CEILING FINISH UNLESS OTHERWISE REQUIRED BY
CODE. COORDINATE WITH MECHANICAL / ELECTRICAL FOR FINISHES ON
MECHANICAL OR ELECTRICAL EQUIPMENT.
DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL SURFACES,
OPERATING PARTS, LABELS OR WARNINGS.
REFER TO AND COORDINATE WITH FURNITURE DRAWINGS AND TYPICAL
MOUNTING HEIGHTS DRAWING FOR WALL MOUNTING HEIGHTS OF FF&E,
VISUAL DISPLAYS AND AUDIO VISUAL EQUIPMENT.
PROVIDE SOLID SURFACE WINDOW SILLS AT ALL WINDOWS (SSF-1).
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
A M
A S
H E
K E
L
A F
D R
A W
IN
G
C O
D E
E L L S
W O
R T
H A
IR
F
O R
C E
B A
S E
S
D
P N
F X
B M
F
Y
B -2
L
O W
O B
S E
R V
A B
L E
-B
A Y
R E
S T
O R
A T
IO
N
F A
C
IL
IT
Y
A P
R
IL
A D
V E
R T
IS
E
M E
N T
D
E S
IG
N
W F
-2 -R
-0
A-701
R O
O M
F
IN
IS
H
S C
H E
D U
L E
L
E G
E N
D
T .K
IM
E .A
L L E
N
P .W
A L T
E R
S
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME
FLOOR BASE WALLS
CEILING REMARKSFINISH FINISH
NORTH EAST SOUTH WEST
FINISH FINISH FINISH FINISH
136A SECURE VEST EF-1 - PA-1 PA-1 PA-1 PA-1 PAINTED GYP., PA-4
137 AIR SHOWER EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
138 INITIAL ACCUMULATION POINT EF-2 EF-2 TLP-1/PE-1 PE-1 PE-1 PE-1 PAINTED GYP., PA-4
139 (M) DIRTY EF-2 EF-2 TLP-1/PE-1 TLP-1/PE-1 TLP-1/PE-1 PE-1 PAINTED GYP., PA-4
140 (M) DIRTY SHOWER EF-2 EF-2 PE-1/SSF-2 TLP-1/PE-1/
SSF-2
PE-1/SSF-2 PE-1 PAINTED GYP., PA-4
141 (M) CLEAN EF-2 EF-2 TLP-1/PE-1 TLP-1/PE-1 TLP-1/PE-1 TLP-1/PE-1 PAINTED GYP., PA-4
142 (M) CLEAN SHOWER EF-2 EF-2 PE-1/SSF-2 PE-1 PE-1/SSF-2 TLP-1/PE-1
/SSF-2
PAINTED GYP., PA-4
143 JAN EF-2 EF-2 PA-1 PA-1 FRP-1/PA-1 FRP-1/PA-1 PAINTED GYP., PA-4
144 (W) CLEAN EF-2 EF-2 TLP-1/PE-1 TLP-1/PE-1 TLP-1/PE-1 PE-1 PAINTED GYP., PA-4
145 (W) CLEAN SHOWER EF-2 EF-2 TLP-1/PE-1/
SSF-2
PE-1/SSF-2 TLP-1/PE-1/S
SF-2
PE-1 PAINTED GYP., PA-4
146 (W) DIRTY SHOWER EF-2 EF-2 TLP-1/PE-1/
SSF-2
PE-1/SSF-2 TLP-1/PE-1/S
SF-2
PE-1 PAINTED GYP., PA-4
147 (W) DIRTY EF-2 EF-2 TLP-1/PE-1 TLP-1/PE-1 TLP-1/PE-1 PE-1 PAINTED GYP., PA-4
148 ELEC EF-2 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
149 FIELD TRAINING DETACHMENT EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1
150 SILICONE SANDING
ROOM
EF-1 - PA-1 PA-1 PA-1 PA-1 PAINTED GYP., PA-4
151 COMPOSITE SANDING ROOM EF-1 - PA-1 PA-1 PA-1 PA-1 PAINTED GYP., PA-4
151A SECURE VEST EF-1 - PA-1 PA-1 PA-1 PA-1 PAINTED GYP., PA-4
152 AIR SHOWER EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
153 PAINT BOOTH EF-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
154 CORRIDOR EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
154A CORRIDOR EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
154B CORRIDOR EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
155 CORRIDOR EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1
156 FOAM ROOM CH-1 - PA-1 PA-1 PA-1 PA-1 CONCRETE LID
157 VEST WOM-1 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
158 STORAGE EF-2 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
159 AHU CH-1 - PA-1 PA-1 PA-1 PA-1 PAINTED GYP., PA-4
SECOND FLOOR
200 MECHANICAL CH-1 RB-1 PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4 IMPACT RESISTANT
GYP. BD. BOTTOM 8'-0"
TYP.
201 STAIR 01 CH-3 - PA-1 PA-1 PA-1 PA-1 EXPOSED
CONCRETE
STAIR TREADS TO BE
CH-2. ALL OTHER
FLOOR SURFACES IN
STAIRWELL TO BE
CH-3 U.O.N.
202 STAIR 02 CH-3 - PA-1 PA-1 PA-1 PA-1 EXPOSED
CONCRETE
STAIR TREADS TO BE
CH-2. ALL OTHER
FLOOR SURFACES IN
STAIRWELL TO BE
CH-3 U.O.N.
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME
FLOOR BASE WALLS
CEILING REMARKSFINISH FINISH
NORTH EAST SOUTH WEST
FINISH FINISH FINISH FINISH
GROUND FLOOR
101 SUPPLY PLENUM CH-3 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
102 HANGAR BAY 1 EF-1 EF-1 PA-1 PA-1 PA-1 PA-1 WALKABLE
103A EXHAUST PLENUM CH-2 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
103B EXHAUST PLENUM CH-2 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
104 VEST EF-1 RB-1 PA-1 PA-1 PA-1 PA-1 CONCRETE LID
105 VEST EF-1 RB-1 PA-1 PA-1 PA-1 PA-1 CONCRETE LID
107 AIR COMPRESSOR CH-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
108 ELEC CH-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
109 FOAM ROOM CH-1 - PA-1 PA-1 PA-1 PA-1 CONCRETE LID
110 BOILER ROOM CH-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
112 SECURE OFFICE EF-2 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1
112A SECURE VEST EF-2 RB-1 PA-1 PA-1 PA-1 PA-1 ACT-1
114 OFFICE EF-2 RB-1 PA-3 PA-2 PA-2 PA-2 ACT-1
115 BREAK ROOM EF-2 / EF-3 /
EF-4
RB-1 PA-3 PA-2 PA-2 PA-3 ACT-2 / ACT-3 /
PAINTED GYP., PA-4
116 LOCKER ROOM EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
117 VEST WOM-1 RB-1 PA-2 PA-2 PA-2 PA-2 PAINTED GYP., PA-4
118 TRAINING ROOM EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1
119 OFFICE EF-2 RB-1 PA-2 PA-2 PA-3 PA-2 ACT-1
120 OFFICE EF-2 RB-1 PA-2 PA-2 PA-3 PA-2 ACT-1
121 MOTHERS ROOM EF-2 RB-1 PA-2 PA-2 PA-2 PA-2 ACT-1
122 COMM CH-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
123 FABRICATION EF-2 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
124 FIRE PUMP CH-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
125 TOOL / SUPPORT EQUIP EF-2 - PA-1 - PA-1 PA-1 EXPOSED, PA-4
126 HAZMAT/ LO STORAGE M-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4 CH-1 ON CONCRETE
BELOW M-1
127 DEMIL CH-1 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
129 VEST EF-1 - PA-1 PA-1 PA-1 PA-1 CONCRETE LID
130A EXHAUST PLENUM CH-2 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
130B EXHAUST PLENUM CH-2 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
131 VEST EF-1 - PA-1 PA-1 PA-1 PA-1 CONCRETE LID
132 HANGAR BAY 2 EF-1 EF-1 PA-1 PA-1 PA-1 PA-1 WALKABLE
133 SUPPLY PLENUM CH-3 - PA-1 PA-1 PA-1 PA-1 EXPOSED, PA-4
134 STAIR 02 CH-3 - PA-1 PA-1 PA-1 PA-1 CONCRETE LID STAIR TREADS TO BE
CH-2. ALL OTHER
FLOOR SURFACES IN
STAIRWELL TO BE
CH-3 U.O.N.
135 STAIR 01 CH-3 - PA-1 PA-1 PA-1 PA-1 CONCRETE LID STAIR TREADS TO BE
CH-2. ALL OTHER
FLOOR SURFACES IN
STAIRWELL TO BE
CH-3 U.O.N.
136 LO PART STORAGE EF-1 - PA-1 PA-1 PA-1 PA-1 PAINTED GYP., PA-4
FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT
MATERIAL DESCRIPTION MANUF. MODEL NUMBER PRODUCT NUMBER COLOR REMARKS
BASE
RB-1 RUBBER BASE ROPPE - 177 STEEL BLUE
CASEWORK
PLAM-1 PLASTIC LAMINATE FORMICA 8909-NG - CASCARA TEAKWOOD
SS-1 STAINLESS STEEL - - - -
SSF-1 SOLID SURFACE WILSONART - 9218CM GREY BEOLA
CEILING
ACT-1 24" x 24" / 15/16" SQUARE ARMSTRONG OPTIMA TEGULAR 3354 WHITE
ACT-2 24" x 24" METAL CEILING PANEL / PERFORATED ARMSTRONG METALWORKS TEGULAR 6462 WHITE / M3
ACT-3 8" ALUMINUM TRIM - ACOUSTICAL CEILING TRIM ARMSTRONG AXIOM TRIM TO MATCH SW9150 ENDLESS SEA
PA-4 ACRYLIC/LATEX; CEILING SHERWIN WILLIAMS - SW7007 CEILING BRIGHT WHITE / EGGSHELL
FLOORING
CH-1 CONCRETE - HARDENED/SEALER - - - -
CH-2 CONCRETE - UNFINISHED - - - -
CH-3 CONCRETE - HARDENED/SEALER WITH BROOM FINISH - - - -
EF-1 EPOXY FLOORING - 3 COAT HANGAR FLOOR TENNANT CO. HEAVY DUTY TROWELED EPOXY MORTAR SYSTEM - WHITE 1.
EF-2 BROADCAST FLAKE EPOXY - COLOR TO MATCH SHERWIN WILLIAMS, 6" BASE TENNANT CO. FLAKE DB - CHIPS UNLIMITED CUSTOM MIX C12-661 / C22-712 / C12-910 6248 JUBILEE 12% / 6246 NORTH STAR 75% / 6250 GRANITE PEAK 13%
EF-3 BROADCAST FLAKE EPOXY - COLOR TO MATCH SHERWIN WILLIAMS TENNANT CO. FLAKE DB - CHIPS UNLIMITED CUSTOM MIX C12-661 / C22-712 / C12-910 6248 JUBILEE 75% / 6246 NORTH STAR 12% / 6250 GRANITE PEAK 13%
EF-4 BROADCAST FLAKE EPOXY - COLOR TO MATCH SHERWIN WILLIAMS TENNANT CO. FLAKE DB - CHIPS UNLIMITED CUSTOM MIX C12-661 / C22-712 / C12-910 6248 JUBILEE 12% / 6246 NORTH STAR 13% / 6250 GRANITE PEAK 75%
M-1 STEEL GRATING - - - -
WOM-1 WALK-OFF MAT SHAW CONTRACT STEPPIN OUT / WELCOME II TILE 5T031 31549 CHARCOAL SPECIFICATION 09 68 00
MISCELLANEOUS
GR-1 GROUT TEC SPECIALTIES - - 934 DELOREAN GRAY
SC-1 NYLON REINFORCED ANITIMICROBIAL SHOWER CURTAIN BRADLEY - 9537 WHITE
SG-1 SIGNAGE MESSAGE COLOR - MATTE FINISH ASI SIGNAGE INNOVATIONS - SC-901 WHITE
SG-2 SIGNAGE BACKGROUND COLOR - MATTE FINISH ASI SIGNAGE INNOVATIONS - SC-904 DARK GREY
TP-1 TOILET PARTITIONS AND URINAL SCREENS SCRANTON PRODUCTS HINY HIDERS - HAMMERED / STAINLESS
WALL
AP-1 ACOUSTICAL WALL PANEL DESIGNTEX MOUNTAINOUS 3034-802 GRAPHITE
CG-1 CORNER GUARD KOROSEAL KOROGARD GS SERIES GS15 S6 STAINLESS STEEL, 2"
FRP-1 FIBERGLASS REINFORCED PANEL MARLITE - 430N MEDIUM GREY
PA-1 ACRYLIC/LATEX; WALL - HANGAR/SHOPS SHERWIN WILLIAMS - SW7757 HIGH REFLECTIVE WHITE / EGGSHELL
PA-2 ACRYLIC/LATEX; WALL - ADMIN/RESTROOMS SHERWIN WILLIAMS - SW6248 JUBILEE / EGGSHELL
PA-3 ACRYLIC/LATEX; ACCENT SHERWIN WILLIAMS - SW9150 ENDLESS SEA / EGGSHELL
PA-5 ACRYLIC/LATEX; TRIM SHERWIN WILLIAMS - SW6250 GRANITE PEAK / EGGSHELL
PE-1 EPOXY; WET WALLS SHERWIN WILLIAMS - SW6248 JUBILEE / EGGSHELL
SSF-2 SOLID SURFACE; WALLS & SHOWER BASE INPRO BIOPRISM P9013 LUNAR
TLP-1 12" X 24" PORCELAIN CROSSVILLE ARGENT - CLEAN SLATE / HONED
EF-1 BASE BID TO BE 3-COAT SYSTEM FUEL RESISTIVE RESINOUS
FLOORING PER SPECIFICATION 09 67 23.15. BID OPTION TO BE 5-COAT
SYSTEM FUEL RESISTIVE RESINOUS FLOORING PER SPECIFICATION 09 67
23.16.
FINISH LEGEND REMARK:
1.
A
M -0
D
E S
IG
N
I S
S U
E D
F O
R P
R
IC
IN
G
A P
R
A
M E
N D
M E
N T
M A
Y
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
A M
A S
H E
K E
L
A F
D R
A W
IN
G
C O
D E
E L L S
W O
R T
H A
IR
F
O R
C E
B A
S E
S
D
P N
F X
B M
F
Y
B -2
L
O W
O B
S E
R V
A B
L E
-B
A Y
R E
S T
O R
A T
IO
N
F A
C
IL
IT
Y
A P
R
IL
A D
V E
R T
IS
E
M E
N T
D
E S
IG
N
W F
-2 -R
-0
AG002
A R
C H
IT
E
C T
U R
A L G
E N
E R
A L N
O T
E S
T .K
IM
J .C
O B
L E
R
P .W
A L T
E R
S
ARCHITECTURAL GENERAL NOTES
49. ALL EXTERIOR WALL MOUNTED ELEMENTS ON CMU SHALL BE
INSTALLED OVER SMOOTH FACE CMU. CONTRACTOR SHALL
COORDINATE ALL EXTERIOR WALL MOUNTED ELEMENTS BEFORE
EXTERIOR WALL INSTALLATION. PROVIDE SMOOTH FACE CMU AS
REQUIRED WHERE WALL MOUNTED ELEMENTS ARE MOUNTED.
50. ALL EXTERIOR WALL MOUNTED ELEMENTS OVER RIBBED METAL
PANELS MUST BE INSTALLED OVER 14GA, PAINTED, GALVANIZED
SHEET METAL UNLESS NOTED OTHERWISE. SEE DETAIL A9/A-523.
51. ALL METAL WALL PANELS MUST BE CONTINUOUS WITHOUT
JOINTS UNLESS NOTED OTHERWISE.
52. CONSTRUCTION FOR SECURE AREAS, AND SECURE AREA
MATERIAL AND COMPONENTS, MUST COMPLY WITH UFC 4-010-05
AND IC TECH SPECS FOR ICD/ICS 705 AND FULLY MEET AND PASS
ALL ACCREDITATION.
53. CONTRACTOR MUST PROVIDE ACOUSTICAL TESTING OF SECURE
AREAS IN ORDER TO DEMONSTRATE CONFORMANCE WITH
REQUIREMENTS INDICATED IN DOCUMENTS. CONTRACTOR SHALL
HIRE AN INDEPENDENT ACOUSTICAL TESTING AGENCY TO
PERFORM ACOUSTICAL TESTS IN ACCORDANCE WITH ASTM
E336-20 STANDARD TEST METHOD FOR MEASUREMENT OF
AIRBORNE SOUND ATTENUATION BETWEEN ROOMS IN BUILDINGS.
TESTING MUST BE CONDUCTED TO DETERMINE THE APPARENT
SOUND TRANSMISSION CLASS (ASTC) AND APPARENT
TRANSMISSION LOSS (ATL) AS INDICATED IN THE ASTM
STANDARD. CONTRACTOR MUST PROVIDE ONE TEST PER
SECURE AREA IN THE PRESENCE OF THE CONTRACTING OFFICER
AND SITE SECURITY OFFICER. THE ACCREDITING OFFICER MUST
BE NOTIFIED IN ADVANCE AND HAVE THE OPTION TO ATTEND
TESTING IF POSSIBLE. TEST LOCATIONS IN THE BUILDING MUST
BE DETERMINED BY THE SITE SECURITY OFFICER. CONTRACTOR
IS RESPONSIBLE FOR PROVIDING A COMPLETE REPORT OF EACH
TEST IN ACCORDANCE WITH SECTION 13 OF ASTM E336.
CONTRACTOR MUST BE RESPONSIBLE FOR REMEDIATING FAILED
TESTS AND MUST HAVE FAILED LOCATIONS RE-TESTED TO
DEMONSTRATE COMPLIANCE.
26. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF
ALL PENETRATIONS IN THE STRUCTURE FOR THE PROPER
INSTALLATION OF THE WORK. REFER TO STRUCTURAL
DRAWINGS FOR SECONDARY FRAMING AND/OR REINFORCING
REQUIRED AT PENETRATIONS IN STEEL, CONCRETE OR
MASONRY.
27. THE CONTRACTOR MUST PROVIDE ACCESS DOORS OR PANELS
AS REQUIRED FOR SERVICING OF PIPING, DUCTWORK, CABLE
TRAYS, FIRE DAMPERS AND SIMILAR APPLICATIONS. ALL
PROPOSED ACCESS DOOR LOCATIONS TO BE SUBMITTED FOR
APPROVAL PRIOR TO INSTALLATION.
28. PROVIDE ALL HVAC, PLUMBING, GAS OR ELECTRIC SERVICE
CONNECTIONS TO CASEWORK, FIXTURES, SIGNAGE, OR
EQUIPMENT INDICATED (WHETHER UNITS ARE INSTALLED BY
CONTRACTOR OR BY OTHERS).
29. BRACE PARTITIONS, SUSPENDED CEILINGS, SOFFITS,
SUSPENDED ITEMS, ETC. ONLY TO STRUCTURAL ELEMENTS
ABOVE. DO NOT ANCHOR TO ROOF DECK, PLUMBING / SPRINKLER
PIPES, DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR ELEMENTS.
REFER TO SECTION 13 48 73 SEISMIC CONTROL FOR MECHANICAL
EQUIPMENT FOR MORE INFORMATION.
30. EXTEND ALL FLOORING AND WALL-BASE COMPLETELY INTO
RECESSES, UNDER OPEN COUNTERTOPS, AND BEHIND ALL
EQUIPMENT.
31. ALL MATERIALS USED FOR CONSTRUCTION MUST BE NEW AND
UNDAMAGED. THE CONTRACTOR MUST SUBMIT SHOP DRAWINGS
AS REQUIRED IN THE SPECIFICATIONS.
32. THE CONTRACTOR MUST BECOME FULLY ACQUAINTED WITH
CONDITIONS RELATED TO THE WORK. ANY DISCREPANCIES
BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS MUST
BE REPORTED TO THE DESIGN PROFESSIONALS FOR
RESOLUTION PRIOR TO PROCEEDING WITH THE WORK.
33. DRAWINGS CONTAINED IN THIS SET MUST NOT BE REPRODUCED
FOR SHOP DRAWINGS. COPIES OF THESE DRAWINGS SUBMITTED
AS SHOP DRAWINGS WILL BE REJECTED AND RETURNED TO THE
CONTRACTOR.
34. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR
CONDITIONS UNDER WHICH THE WORK WILL BE INSTALLED AND
REPORT TO THE CONTRACTOR IN WRITING ANY CONDITIONS
DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THE
INSTALLERS WORK. DO NOT PROCEED UNTIL UNSATISFACTORY
CONDITIONS ARE CORRECTED. INSTALLATION MUST CONSTITUTE
ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.
35. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS MUST MEAN
THAT THE CONDITIONS OR DIMENSION IS THE SAME OR
REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.
36. CONTROL JOINTS (CJ) MUST BE INSTALLED AT ALL PARTITIONS.
CJ AT GYPSUM PARTITIONS MUST BE MAXIMUM 30'-0" O.C., CJ AT
CONCRETE MASONRY UNIT PARTITIONS MUST BE MAXIMUM 20'-0"
O.C., UNLESS OTHERWISE NOTED ON DRAWINGS. REFER TO
ELEVATION DRAWINGS FOR EXTERIOR CONTROL JOINT
LOCATIONS. REVIEW CJ LOCATIONS WITH COR PRIOR TO
INSTALLATION.
37. NON-BEARING PARTITIONS MUST BE ISOLATED FROM THE
BUILDING STRUCTURE TO PREVENT TRANSFER OF BUILDING
LOADS FROM THE STRUCTURE TO THE PARTITIONS.
38. NOT USED.
39. NOT USED.
40. NOT USED.
41. WHERE EXISTING FINISHED SURFACES ARE CUT SO THAT A
SMOOTH TRANSITION WITH NEW WORK IS NOT POSSIBLE,
TERMINATE EXISTING SURFACE ALONG A STRAIGHT LINE AT A
NATURAL LINE OF DIVISION AND MAKE RECOMMENDATION TO
COR.
42. PROTECT EXISTING WORK TO REMAIN. PERFORM CUTTING TO
ACCOMPLISH REMOVALS NEATLY AND AS SPECIFIED FOR
CUTTING NEW WORK. REPAIR ADJACENT CONSTRUCTION AND
FINISH DAMAGED DURING REMOVAL WORK. PATCH AS SPECIFIED
FOR PATCHING NEW WORK.
43. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE EXTENT,
NATURE, AND SCOPE OF WORK DESCRIBED IN THE CONTRACT
DOCUMENTS AND COORDINATING WITH THE COR THE
INTERFACING OF THE EXISTING BUILDING AND THE WORK SHOWN
AND DESCRIBED IN THESE CONTRACT DOCUMENTS.
44. ALL "EXISTING" INFORMATION ON THE CONTRACT DOCUMENTS
HAS BEEN OBTAINED FROM A PREVIOUS SET OF DRAWINGS, OR
FROM FIELD INVESTIGATION AND SUCH "EXISTING" INFORMATION
MUST BE FIELD VERIFIED BY ALL CONTRACTORS.
45. NOT USED.
46. NOT USED.
47. BASIS OF DESIGN PRODUCTS ARE NOT INTENDED TO LIMIT THE
SELECTION FROM OTHER MANUFACTURERS. HOWEVER PRODUCT
QUALITY MUST MATCH TO BASIS OF DESIGN PRODUCT AND
SPECIFICATION REQUIREMENTS.
48. PROVIDE SEALANT AT ALL JOINTS AT ROOFS, WALL SYSTEMS,
PENETRATIONS, FLASHINGS, AND OPENINGS.
1. ALL WORK MUST COMPLY WITH ALL APPLICABLE CODES AND
STANDARDS AS LISTED OR REFERENCED ON LIFE SAFETY PLAN
AND LIFE SAFETY CRITERIA.
2. THE CONTRACTOR MUST INCLUDE ALL WORK REQUIRED TO
COMPLY WITH ALL APPLICABLE CODES AND STANDARDS AS
LISTED OR REFERENCED ON LIFE SAFETY PLAN AND LIFE SAFETY
CRITERIA.
3. DIMENSIONS MUST GOVERN. DETAILS MUST GOVERN OVER
PLANS AND ELEVATIONS. LARGE SCALE DETAILS OR PLANS MUST
GOVERN OVER SMALL SCALE DETAILS OR PLANS. DO NOT SCALE
DRAWINGS.
4. THE GENERAL CONTRACTOR MUST PROVIDE AND INSTALL ALL
EXIT SIGNS, EMERGENCY LIGHTING SYSTEMS, ALARM SYSTEMS
AND AUTOMATIC SPRINKLER SYSTEMS AS REQUIRED BY
APPLICABLE CODES AND STANDARDS OR AS REQUIRED BY THE
AUTHORITY HAVING JURISDICTION.
5. ALL FLOORS MUST BE INSPECTED FOR DAMAGE, WARPING OR
OTHER NOTICEABLE DEVIATIONS AND PATCHED AND LEVELED
PRIOR TO COVERING WITH FLOOR FINISHES, INSTALLATION OF
FLOOR GRATING SYSTEM, OR ERECTION AND INSTALLATION OF
COLD-FORMED FRAMING. TEST FLOOR SLAB MOISTURE CONTENT
BEFORE FLOOR FINISH INSTALLATION AS REQUIRED PER
SPECIFICATION.
6. THE GENERAL CONTRACTOR MUST BE RESPONSIBLE FOR
PROVIDING ALL MANUFACTURER'S RECOMMENDED
MAINTENANCE PROCEDURES AND SCHEDULES.
7. NOT USED.
8. ALL CONSTRUCTION MUST MEET OR EXCEED SPECIFIED
STANDARDS. DETAILS ARE PROVIDED TO INDICATE MINIMUM
QUALITY AND TO GIVE STANDARDS OF CONSTRUCTION. IF A
CONDITION IS NOT SPECIFICALLY DETAILED, SUBMIT A SIMILAR
DETAIL FOR GUIDANCE AND APPROVAL.
9. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS,
SECTIONS OR ELEVATIONS.
10. PROVIDE PRESERVATIVE-TREATED WOOD AT ALL LOCATIONS
WHERE WOOD IS IN DIRECT CONTACT WITH CONCRETE,
MASONRY AND GROUND.
11. PROVIDE 3/4" FIRE-RETARDANT TREATED PLYWOOD BACKING AT
ALL ELECTRICAL, PHONE, AND SECURITY SYSTEM PANELS.
ENSURE ALL LABELS ARE CLEAR OF PAINT AND NOT COVERED.
12. PROVIDE FIRE-RESISTANT TREATED WOOD BLOCKING OR 20
GAUGE MINIMUM METAL BACKING FOR SECURE ANCHORAGE OF
ALL SHELVES, RUNNING TRIM, RAILINGS, SUSPENDED ITEMS,
DOOR-STOPS, GRAB-BARS, AND OTHER SIMILAR WOODWORK,
HARDWARE, SPECIALTIES, ACCESSORIES, FIXTURES, OR
EQUIPMENT.
13. PROVIDE CEMENTITIOUS BACKER UNIT AT ALL AREAS WHERE A
TILE SURFACE IS TO BE INSTALLED ON METAL STUD WALLS.
14. PROVIDE WATER-RESISTANT GYPSUM BOARD AT ALL WET OR
UNCONDITIONED AREAS INCLUDING, BUT NOT LIMITED TO,
PARTITIONS BEHIND SINKS. CONTRACTOR TO ENSURE THAT FIRE
RATING IS MAINTAINED.
15. PAINT, STAIN, OR COAT ALL EXPOSED SURFACES OF
CONSTRUCTION UNLESS NOTED OTHERWISE OR IF SURFACES
ARE PRE-FINISHED.
16. ALL OPENING DIMENSIONS ARE NOMINAL. THE CONTRACTOR
MUST FIELD MEASURE ALL OPENINGS AND COORDINATE WITH
THE APPROPRIATE SUPPLIER FOR ALL DOORS AND WINDOWS.
17. ALL CONDUITS, PLUMBING, PIPING, DUCTWORK, AND OTHER
EQUIPMENT EXPOSED TO VIEW MUST BE LOCATED PARALLEL OR
PERPENDICULAR TO THE STRUCTURAL FRAMING SYSTEM.
18. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR
MATERIALS, WHERE REQUIRED.
19. FIBERGLASS REINFORCED PANELS TO BE INSTALLED UP TO 4'-10"
ABOVE WALL BASE AT ALL MOP SINK LOCATIONS. EXTENT OF
PANELS VARIES BY LOCATION. REFER TO FINISH SCHEDULE,
WALL FINISH DRAWINGS, AND INTERIOR ELEVATIONS.
20. ARCHITECTURAL DETAILS ARE APPLICABLE WHERE INDICATED BY
SECTION CUT, BY NOTE, OR BY DETAIL TITLE. INCORPORATE
SIMILAR DETAILS AT SIMILAR CONDITIONS UNLESS NOTED
OTHERWISE. THE CONTRACTOR MAY REQUEST A CLARIFICATION
IF REQUIRED, OTHERWISE THE MORE STRINGENT
REQUIREMENTS MUST CONTROL.
21. PROVIDE FIRE-STOPPING SYSTEMS AT TOP OF AND AT ALL
PENETRATIONS THROUGH FIRE-RATED WALL ASSEMBLIES AND
FIRE RATED FLOOR ASSEMBLIES.
22. SEAL ALL EXTERIOR BUILDING JOINTS AT BOTH THE EXTERIOR
AND INTERIOR SURFACES AGAINST MOISTURE AND AIR
INFILTRATION.
23. SEAL AROUND ALL DOOR AND WINDOW FRAMES, COUNTERTOPS,
WALL-MOUNTED FIXTURES AND EQUIPMENT TO ADJACENT WALL
SURFACES.
24. THE CONTRACTOR MUST REVIEW THE DIMENSIONS OF ALL
EQUIPMENT IN THE PROJECT REGARDLESS OF THE SOURCE AND
COORDINATE ACCESS TO THE SPACE AND VERIFY CLEAR FLOOR
SPACE IS PROVIDED AS REQUIRED TO ENSURE EASE OF
INSTALLATION.
25. ALL WORK MUST BE OF GOOD QUALITY, FREE FROM DEFECTS,
AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE
CONTRACT DOCUMENTS.
A
M -0
D
E S
IG
N
I S
S U
E D
F O
R P
R
IC
IN
G
A P
R
A
M E
N D
M E
N T
M A
Y
GENERAL NOTES:
1. ALL DIMENSIONS, ELEVATIONS, AND STATIONS ARE IN FEET UNLESS
INDICATED.
2. ALL PIPE SIZES ARE IN INCHES UNLESS INDICATED OTHERWISE.
3. CALLOUTS, COORDINATES, ELEVATIONS, AND DIMENSIONS ARE
POINTED TO OR MEASURED TO STRUCTURE CENTER, EDGE OF
PAVEMENT, BACK OF CURB, OUTSIDE FACE OF FOUNDATION WALL
OR COLUMN CENTERLINE, UNLESS INDICATED OTHERWISE.
EXISTING CONDITION NOTES:
1. THE LOCATIONS OF STRUCTURES AND UNDERGROUND UTILITIES
AS INDICATED HAVE BEEN OBTAINED FROM EXISTING RECORDS
AND FIELD SURVEYS. UNDERGROUND STRUCTURES AND UTILITIES
MAY BE PRESENT WHICH ARE NOT DOCUMENTED OR LOCATED.
2. THE CONTRACTOR SHALL FIELD-CHECK ALL EXISTING CONDITIONS
AND BE THOROUGHLY FAMILIAR WITH THE SITE BEFORE ANY WORK
COMMENCES. ANY DISCREPANCIES IN THE DRAWINGS SHALL BE
IMMEDIATELY REPORTED TO THE CONTRACTING OFFICER BEFORE
ANY FURTHER WORK COMMENCES.
3. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO FIELD-VERIFY
EXISTING STRUCTURES, UTILITIES, AND SURVEY INFORMATION, AND
TO TAKE NECESSARY PRECAUTIONS DURING DEMOLITION AND
CONSTRUCTION. CONTRACTOR SHALL VERIFY EXISTENCE AND
MARK LOCATIONS OF ALL UTILITIES, INCLUDING SERVICE
CONNECTIONS TO UNDERGROUND UTILITIES PRIOR TO BEGINNING
WORK. CONTRACTOR SHALL CONTACT THE CONTRACTING OFFICER
AND ALL ASSOCIATED UTILITY COMPANIES AND AGENCIES TO
IDENTIFY THE LOCATION OF UTILITIES. THERE IS NO GUARANTEE,
EITHER EXPRESSED OR IMPLIED, THAT THE LOCATIONS, SIZE AND
TYPE OF MATERIAL OF EXISTING UNDERGROUND UTILITIES
INDICATED ARE REPRESENTATIVE OF THOSE TO BE ENCOUNTERED
DURING CONSTRUCTION.
4. PRIOR TO CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY THE
CONTRACTING OFFICER OF OPERATIONAL PLANS. IN THE EVENT AN
UNEXPECTED UTILITY OR STRUCTURE INTERFERENCE OR
CONFLICT IS ENCOUNTERED DURING CONSTRUCTION, THE
CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CONTRACTING
OFFICER. ANY UTILITY SERVICES OR STRUCTURES DISTURBED BY
THE CONTRACTOR'S OPERATIONS SHALL BE RESTORED
IMMEDIATELY AT CONTRACTOR'S EXPENSE TO THE SATISFACTION
OF THE CONTRACTING OFFICER.
5. THE CONTRACTOR IS RESPONSIBLE FOR PROTECTING ITEMS NOT
TO BE DAMAGED DURING DEMOLITION AND CONSTRUCTION. THE
CONTRACTOR SHALL REPAIR OR REPLACE DAMAGED OR
DISTURBED ITEMS TO THE SATISFACTION OF THE CONTRACTING
OFFICER.
6. SITE AND UTILITY WORK WILL BE OCCURRING IN AREAS WITH
CONTAMINATED SOIL AND SOIL REQUIRING SPECIAL HANDLING. ALL
SOIL HANDLING, SCREENING, SAMPLING AND DISPOSAL SHALL BE
COMPLETED IN ACCORDANCE WITH SPECIFICATION SECTION 02 61
13 AND ALL FEDERAL, STATE, AND LOCAL REQUIREMENTS,
CONTRACTOR SHALL COORDINATE REMOVAL OF CONTAMINATED
MATERIALS WITH THE CONTRACTING OFFICER.
7. THE ASBESTOS AND LEAD PAINT INVESTIGATION FOR THE EXISTING
BUILDINGS, INCLUDING DOCK 60, HAS BEEN PERFORMED. THE
RESULTS OF THE INVESTIGATION ARE CONTAINED IN THE APPENDIX
TO THE PROJECT SPECIFICATIONS.
DEMOLITION NOTES:
1. ALL DEMOLITION, WASTE, DEBRIS, AND UNSATISFACTORY
MATERIALS SHALL BE DISPOSED OF OFF BASE IN ACCORDANCE
WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.
2. LOCATIONS NOTED FOR DEBRIS REMOVAL MAY CONTAIN ANY OF
THE FOLLOWING MATERIALS: AGGREGATE, CONCRETE, ASPHALT,
MASONRY, FOUNDATIONS, REBAR, FENCE MATERIAL, PIPING, AND
MISCELLANEOUS STRUCTURES. LARGE PIECES OF MATERIAL MAY
NEED TO BE CRUSHED AND/OR BROKEN UP FURTHER IN ORDER TO
BE HAULED AWAY TO THE WASTE DISPOSAL SITE.
3. HANGAR DOCK 60, AND ALL BUILDING DEMOLITION SHALL INCLUDE
COMPLETE REMOVAL OF ALL STRUCTURES, FOUNDATIONS, AND
UTILITIES ASSOCIATED WITH THE EXISTING BUILDING FOOTPRINT.
UTILITIES NOTED FOR DEMOLITION SHALL BE REMOVED IN THEIR
ENTIRETY AND NOT ABANDONED UNLESS INDICATED OTHERWISE.
ANTICIPATED FOUNDATIONS ARE SHALLOW SPREAD FOUNDATIONS
WITH PERIMETER WALL FOOTINGS AND TIE BEAMS CONNECTING
SOME INTERIOR COLUMN FOOTINGS. FOUNDATIONS ARE
ANTICIPATED TO BE APPROXIMATELY 4.5 FEET TO 5.5 FEET.
4. CONTRACTOR SHALL COORDINATE LIMITS OF SAWCUT AND
PAVEMENT REMOVAL WITH PROPOSED PAVEMENT LAYOUT AND
JOINTING PLAN. ODD SHAPED PANELS AND OTHER AIRFIELD APRON
AND SITE CONCRETE PAVEMENTS MAY CONTAIN REINFORCEMENT.
PAVEMENT DESIGNATED FOR SAWCUT SHALL BE SAWCUT FULL
DEPTH AND DOUBLE CUT (SEE DEMOLITION NOTE 5). EXISTING
PAVEMENT EDGES SHALL BE SAWCUT IN LOCATIONS SHOWN TO
PROVIDE CLEAN EDGE FOR CONSTRUCTION OF PROPOSED
PAVEMENT. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
5. ALL ASPHALT PAVEMENT REMOVALS SHALL BE INITIATED WITH A
FULL DEPTH VERTICAL SAWCUT AT REMOVAL LIMITS AS SHOWN ON
THE PLANS. ALL CONCRETE PAVEMENT REMOVALS SHALL BE
INITIATED USING INITIAL SAWCUT AT EXISTING JOINTS UNLESS
INDICATED OTHERWISE AND THEN ANOTHER SAWCUT MAXIMUM 24
INCHES FROM THE INITIAL JOINT AND AT LEAST 6 INCHES FROM THE
END OF ANY DOWELS PER SPEC SECTION 32 13 14. 13.
6. PAVEMENT REMOVAL LIMITS SHALL BE TO THE NEAREST EXISTING
PAVEMENT JOINT TO THE GREATEST EXTENT POSSIBLE TO
PREVENT PARTIAL PANEL REMOVAL. PARTIAL CONCRETE PANEL
REMOVAL IS NOT ACCEPTABLE FOR AIRFIELD PAVEMENT AREAS
UNLESS OTHERWISE APPROVED OF BY THE DESIGN ENGINEER AND
CONTRACTING OFFICER.
7. PAVEMENT REMOVAL SHALL INCLUDE REMOVAL OF PAVEMENT AND
ANY SUBBASE MATERIAL PRESENT. ALL CONCRETE PAVEMENT
SLABS INDICATED TO BE REMOVED THAT ARE ODD SHAPED OR
CONTAIN STRUCTURAL PENETRATIONS WITHIN (MANHOLES, AREA
INLETS, HYDRANT FUEL PITS, ETC.) SHALL BE CONSIDERED TO BE
REINFORCED WITH STEEL REBAR. EXISTING PAVEMENT IS
REINFORCED IN SOME AREAS, EXTENT OF REINFORCEMENT IS
UNKNOWN.
8. CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING
OFFICER PRIOR TO REMOVAL OF EXISTING UTILITIES IN SERVICE.
RELOCATED UTILITIES SHALL BE CONSTRUCTED BEFORE REMOVAL
OF EXISTING UTILITIES TO ENSURE UNINTERRUPTED SERVICE TO
THE FACILITIES SERVED BY THE UTILITY. ALL RELOCATIONS SHALL
BE COORDINATED WITH THE CONTRACTING OFFICER.
9. UTILITY CAPPING METHODS SHALL BE IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS FOR SPECIFIC PIPE
MATERIAL IN SERVICE. ALL CAPPING SHALL BE INSPECTED AND
APPROVED BY THE CONTRACTING OFFICER PRIOR TO PLACING
BACKFILL.
10. STRUCTURES AND UTILITIES TO BE REMOVED SHALL BE REMOVED
IN ACCORDANCE WITH 02 41 00 DEMOLITION AND BACKFILLED IN
ACCORDANCE WITH SPECIFICATION 31 00 00 EARTHWORK.
11. THE WEIGHT (IN TONS) OF ALL MATERIALS TAKEN OFF THE BASE
FOR RECYCLING SHALL BE REPORTED TO CONTRACTING OFFICER
MONTHLY FOR DOCUMENTATION.
12. ALL INORGANIC MATERIALS IDENTIFIED FOR DEMOLITION AND
REMOVAL SHALL BE DISPOSED OF OFF BASE AND IN ACCORDANCE
WITH ALL LOCAL, STATE, AND FEDERAL REGULATIONS. SUCH
MATERIALS SHALL INCLUDE, BUT IS NOT LIMITED TO, BRICK, TILE,
FIXTURES, UTILITY COMPONENTS AND OTHER SUCH ITEMS. ANY
APPLICABLE MATERIALS SHALL BE CONSIDERED FOR RECYCLE.
13. DUE TO THIS PROJECT'S PROXIMITY TO THE FLIGHTLINE, ALL
CONSTRUCTION DEBRIS WILL BE CONTINUALLY POLICED TO
ENSURE DEBRIS DOES NOT ENTER AN ACTIVE AIRFIELD AREA.
DUMPSTERS WILL BE TARPED AT ALL TIMES.
SITE NOTES:
1. BUILDING COORDINATES ARE INDICATED TO OR MEASURED AT THE
CENTER OF BUILDING COLUMNS. CONTRACTOR SHALL
COORDINATE BEARINGS OF BUILDING GRID LINES WITH
STRUCTURAL DRAWINGS.
2. CONTRACTOR SHALL COORDINATE BUILDING ENTRANCES,
EGRESSES, WALKWAYS, AND DOORWAY LOCATIONS WITH
ARCHITECTURAL AND STRUCTURAL SHEETS. STOOPS AND
SIDEWALKS CENTERED ON DOORS.
3. SEE MECHANICAL AND ELECTRICAL SHEETS FOR MISCELLANEOUS
SITE EQUIPMENT DETAILS. SEE STRUCTURAL SHEETS FOR
EQUIPMENT PAD DETAILS.
GRADING NOTES:
1. PROPOSED ELEVATIONS INDICATED ARE FOR TOP OF FINAL GRADE,
PAVEMENT, OR STRUCTURE UNLESS INDICATED OTHERWISE.
2. ELEVATION DENOTED AS “MATCH” ARE INTENDED TO MEET
EXISTING GRADE ELEVATIONS. CONTRACTOR SHALL VERIFY
ELEVATIONS AT TIE-INS AND MATCH POINTS PRIOR TO BEGINNING
CONSTRUCTION.
3. EXTERIOR FINISH GRADES AT BUILDING ENTRANCES AND
DOORWAY THRESHOLDS SHALL BE MAXIMUM 0.25-INCHES BELOW
BUILDING FINISH FLOOR IF A VERTICAL THRESHOLD IS PROVIDED,
AND SHALL BE MAXIMUM 0.5-INCHES BELOW BUILDING FINISH
FLOOR IF A BEVELED THRESHOLD IS PROVIDED, UNLESS INDICATED
OTHERWISE.
4. EXTERIOR FINISH GRADES ADJACENT TO THE BUILDING SHALL BE
6-INCHES BELOW FINISH FLOOR UNLESS INDICATED OTHERWISE.
5. ADEQUATE DRAINAGE SHALL BE MAINTAINED AT ALL TIMES DURING
CONSTRUCTION. ANY DRAINAGE FEATURE OR STRUCTURE
DISTURBED DURING CONSTRUCTION SHALL BE RESTORED TO
EXISTING CONDITIONS OR BETTER SUBJECT TO THE APPROVAL OF
THE CONTRACTING OFFICER.
6. SURFACES AROUND FACILITY SHALL BE GRADED TO PROVIDE
POSITIVE DRAINAGE AWAY FROM BUILDINGS AND PAVEMENTS.
7. THE CONTRACTOR SHALL REMOVE STANDING WATER FROM THE
PROJECT WORK LIMITS AS NECESSARY TO PROTECT SUBGRADE,
SUBBASE, AND/OR BASE COURSE OF NEW PAVEMENT,
SURROUNDING PAVEMENT-TO-REMAIN, OR OTHER COMPLETED
WORKS.
8. TOP ELEVATION OF ALL UTILITY STRUCTURES TO REMAIN SHALL BE
ADJUSTED ACCORDINGLY TO FINISH GRADE ELEVATION.
9. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE
RE-VEGETATED OR SEEDED IN ACCORDANCE WITH THE
SPECIFICATIONS.
10. INSPECTION REPORTS GENERATED BY THE CONTRACTOR AFTER
INSPECTION OF EROSION CONTROL DEVICES SHALL BE SUBMITTED
TO THE CONTRACTING OFFICER IN ACCORDANCE WITH SWPPP.
ELECTRICAL DEMOLITION NOTES:
1. WHERE LIGHT FIXTURES ARE SHOWN TO BE DEMOLISHED,
CONTRACTOR SHALL REMOVE LIGHT FIXTURE, BASE AND
HANDHOLE, ISOLATION TRANSFORMER AND ASSOCIATED WIRE.
SEE DEMOLITION SHEETS FOR AREA OF REMOVAL.
2. CONTRACTOR SHALL TURN OVER EXISTING DEMOLISHED LED LIGHT
FIXTURES TO ELLSWORTH AFB CE OFFICE.
3. CONTRACTOR SHALL DISPOSE OF DEMOLISHED ISOLATION
TRANSFORMERS AND WIRE OFF SITE.
4. IN THE PRESENCE OF THE CONTRACTING OFFICER, PERFORM A
SURVEY OF EXISTING EDGE LIGHTS TO DETERMINE AND LOG THE
LOCATION OF ANY NON-FUNCTIONAL OR DAMAGED UNITS PRIOR TO
REMOVAL OR ALTERATION.
5. BEFORE PERFORMING ANY WORK TO THE AIRFIELD LIGHTING
CIRCUITS, COORDINATE WITH BASE ELECTRICAL TO LOCK OUT/TAG
OUT ALL CIRCUITS AT THE AIRFIELD LIGHTING VAULT. PERFORM
LOCK OUT/TAG OUT PROCEDURES IN ACCORDANCE WITH BASE
REQUIREMENTS.
6. COVER OR DISCONNECT ALL TAXIWAY LIGHTS AND GUIDANCE
SIGNS WITHIN THE CLOSURE AREA.
7. CONTRACTOR SHALL PROVIDE JUMPERS WHERE REQUIRED TO
MAINTAIN POWER TO ALL LIGHTS THAT ARE NOT WITHIN EACH
PHASE LIMITS AS NEEDED. COORDINATE WITH ELLSWORTH
AIRFIELD OPERATIONS AND CONTRACTING OFFICER FOR JUMPER
LOCATIONS.
C-002
C
IV
IL
G
EN
ER
AL
N
O
TE
S
K.
W
AR
TA
D . M
U
ET
IN
G
R . B
AR
U
TH
AM
EN
D M
EN
T
M
AY
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
EL
LS
W O
R
TH
A
IR
F O
R C
E
BA
SE
, S
D O
M
AH
A D
IS
TR
IC
T
C
AP
IT
O
L
AV
EN
U
E O
M
AH
A, N
E
A.
M
AS
H
EK
AP
R
IL
EL
AF
D
R
AW
IN
G
C O
D E:
AD
VE
R
TI
SE
M
EN
T
- 1
D
ES
IG
N
B-
: L O
W O
BS
ER
VA
BL
E 2-
BA
Y
R
ES
TO
R
AT
IO
N F
AC
IL
IT
Y
PN
: F
XB
M
8, F Y
W
AR
D P
AR
KW
AY
, K
AN
SA
S C
IT
Y, M O
W
F-
-R
-0
AP
R
AM
-0
- 1
D
ES
IG
N
IS
SU
ED
F O
R P
R
IC
IN
G
3" (TYP) EXCEPT
IF OTHERWISE
SHOWN
#5 REBAR CONTINUOUS EACH
CORNER 3' LAP SPLICE LENGTH AS
REQUIRED, SEE NOTE 2
#4 REBAR TIES 18" O.C INTERVALS,
SEE NOTE 2
1. PROVIDE SIZE AND NUMBER OF CONDUITS AS INDICATED ON PLAN VIEWS OR ON
THE DUCTBANK SECTIONS, MAINTAINING 3 INCHES OF CONCRETE AROUND THE
OUTSIDE CONDUITS AND 3 INCHES BETWEEN CONDUITS.
2. REBAR AND TIE REINFORCEMENT REQUIRED UNDER TRAFFIC AREAS ONLY.
EXTEND REINFORCEMENT 5' BEYOND THE EDGES OF PAVED AREAS AND ROADS.
3. BACKFILL MATERIAL SHALL BE COMPACTED SELECT FILL TO MATCH THAT WHICH
WAS REMOVED TO INSTALL THE DUCT BANK.
4. REFER TO DETAIL A1 BELOW FOR MATERIALS AND INSTALLATION REQUIREMENTS
WHEN STUBBING UP IN HAZARDOUS AND NON-HAZARDOUS AREAS. REFER TO
DETAIL E14 FOR CONDUIT LABELING REQUIREMENTS. REFER TO SPEC 33 71 02
FOR BENDING RADIUS REQUIREMENTS.
APPLY RED DYE TO TOP OF
CONCRETE FOR DUCTBANK
PLASTIC WITH METAL
WIRE WARNING TAPE
1 1/2" (TYP)
GRADE
3000 PSI CONCRETE
3"
(TYP)
3"
(TYP)
NOTES:
CONDUIT TO EQUIPMENT AS
INDICATED ON PLANS OR (NOTE 4)
SOIL, CONCRETE, ETC
AS INDICATED. SEE
NOTE 3
36" MINIMUM BELOW GRADE UNLESS
OTHERWISE NOTED
J1
TYPICAL CONCRETE ENCASED DUCTBANK CONSTRUCTION - SECTION AND PROFILE
SCALE: NTS
PVC ADAPTER (TYP)
PVC COATED
RGS ELBOW
(TYP) (NOTE 4
PVC TYPE EB-20.
SEE NOTE 1
GRADE
ENCLOSURE (SEE
TABLE BELOW)
EXPLOSION PROOF
UNION (TYP)
EXPLOSION
PROOF SEAL
(TYP)
FLEX CONDUIT (SEE
TABLE BELOW)
18"
MAX
X X X
M A
X
ENCLOSURE (SEE
TABLE BELOW)
FLEX CONDUIT (SEE
ENCLOSURE (SEE
CLASS I, DIVISION 1 CLASS I, DIVISION 2 NON-HAZARDOUS AREA
X X
X
GRADE
BELOW GRADE TRANSITION
10'
MAX
10'
MAX
GRADE
10'
MAX
10'
MAX
GRADE
BELOW GRADE
TRANSITION
BELOW GRADE
TRANSITION
ABOVE GRADE
TRANSITION
A1
TYPICAL CONDUIT AND EQUIPMENT REQUIREMENTS FOR HAZARDOUS AND NON-HAZARDOUS AREAS
SCALE: NTS
NOTES:
1. REFER TO EF001 FOR LEGEND, GENERAL NOTES AND
ABBREVIATIONS.
PLASTIC DUCT SPACERS
PER SPECIFICATION
33 71 02
REFER TO TABLE
BELOW (TYP A/G
AND B/G CONDUIT)
ABOVE GRADE
TRANSITION
SEE NOTE 5
BELOW (TYP)
SEE NOTE 6
BELOW (TYP)
CIRCUIT TYPE
TO - XXXX / FROM - XXXX
MAX. CONDUIT VOLTAGE
CONDUIT
CIRCUIT TYPE (CONTROL,
FIRE ALARM, POWER, ETC.
FROM CIRCUIT SCHEDULE)
B14
TYPICAL CONDUIT NAMEPLATE
SCALE: NTS
1. NAMEPLATES SHALL BE PROVIDED AT 50' INTERVALS FOR ALL
ABOVE GRADE CONDUITS, INDOORS AND OUTDOORS, AND AT
ABOVE GRADE TO BELOW GRADE CONDUIT TRANSITION LOCATIONS.
NAMEPLATES AND STRAPS SHALL BE 304/316 GRADE STAINLESS
STEEL, ROHS COMPLIANT, NON-FLAMMABLE, UV RESISTANT.
CONTRACTOR SHALL REPAIR ANY DAMAGE TO CONDUIT AND/OR
CONDUIT COATINGS DUE TO APPLYING NAMEPLATES.
SEE NOTE 7
BELOW (TYP)
NOTE:
US Army Corps of Engineers ®
SHEET ID
U
M
Y
C
O R
P
O
F
E
N G
I N
E E
R S
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
S U
B M
I T
T E
D
B
Y
S I Z
E
C H
E C
K E
D
B
Y
A N
S I
D
I S
S U
E
D
A T
E
C O
N T
R A
T
N
S O
L I C
I T
A T
I O
N
N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R I P
T I O
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
E L L S
W O
R T
H
A
I
R
B
S
E
S
D
O M
A H
A
D
I S
T R
I C
T
C
A P
I T
O L
A
V E
N U
E
O M
A H
A
N
E
A
M
A S
H E
K
A P
R I L
E L
D
A
W I N
G
C
O D
E
A D
V E
R T
I S
E M
E N
T
D
E S
I G
N
B
L O
W
O
B S
E R
V A
B L
B
Y
S
T O
R A
T I O
N
F
A C
I L I T
Y
P N
F
X B
M
F
Y
W
A R
D
P
A R
K W
A Y
K
A N
S A
S
C
I T
Y
M
O
W F
R
A P
R
A
M
S
I G
N
I S
S U
P
I C
I N
G
EF501
E L
E C
T R
I C
L
T
A I L
S
T
H
O G
A N
L
M
O R
A L E
S F
O W
L E
R
B A
C H
T E
L O
G
O R
M A
N
1. SEE STRUCTURAL DRAWINGS FOR POLE FOUNDATION DETAILS.
2. ALL LUMINAIRE MOUNTING HARDWARE SHALL MATCH COLOR OF
LUMINAIRES AND POLES.
NOTES:
M
I N
CONDUIT AS
INDICATED ON
PLANS
#2/0 AWG TO
POLE AND
GROUND ROD
BOUNDARY SEALS
JUNCTION BOX
GROUNDING LUG
LIQUID TIGHT FLEXIBLE
METAL CONDUIT
10' X 3/4"Ø
COPPER-CLAD STEEL
GROUND ROD
(AUXILIARY)
TO GROUND
COUNTERPOISE
BASE COVER
PIER FOUNDATION
PER STRUCTURAL
DRAWINGS
SPLICE FIXTURE
CONDUCTORS IN
HANDHOLE. ALLOW
ENOUGH SLACK FOR
HANDLING OUTSIDE OF
POLE
FIXTURE QTY AND TYPE AS
INDICATED ON PLAN AND LIGHT
FIXTURE SCHEDULE
ALUMINUM ROUND
TAPERED POLE PAINTED
DARK BRONZE WITH
INTERNAL VIBRATION
DAMPING
" BONDING LUG, BOND POLE
TO GREEN EQUIPMENT
GROUND CONDUCTOR AND
GROUNDING CONDUCTOR TO
AUXILIARY GROUND ROD
HANDHOLE AND COVER
FACTORY INSTALLED
THREADED CONDUIT FITTING
FOR CONDUIT CONNECTION.
F14
AREA LIGHT
SCALE: NTS
A
M E
N D
M E
N T
M A
Y
J J
J J
J
J
J
J J
J
J
J
J J
JJ
J
3 4 5 6 7 8
J
H
ELEC
BOILER ROOM
LOCKER ROOM
OFFICE
114SECURE VEST
112A
SECURE OFFICE
BREAK ROOM
MATCH LINE
A1/ EP101
M A
T C
H L
IN
E
C
E P
MATCH LINE
A1/ EP102
A1
EP401
MR3-27
GFI
WPIU
MR3-27
GFI
WPIU
J3
EP201
E3
EP201
CR3
MR3-4
MR3-4
CR3-5
CR3-4
CR3-5 CR3-4
MR3-5
MR3-4
MR3-4
MR3-7
M R
-7
MR3-7 R1-28 R1-28
MR3-5
R1-8
+36" AFF
R1-16
+36" AFF
R1-16
+36" AFF
R1-18
+36" AFF
R1-18
+36" AFF
R1-28 R1-28 R1-32
R1-8
+36" AFF
R1-21
+36" AFF
R1-21
+36" AFF
R1-17
+36" AFF
R1-17
+36" AFF
R1-32
AC
R4-20R4-20
R4-20R4-20
R1-32
MR3-5
CR3-2 CR3-2
CR3-2
R1-24
R1-24
R1-24
MR3-5
AHU
AIR
COMPRESSOR
MR3-13
MR3-10
MR3-8
MR3-20
MR3-20
MR3-4
CR3-3
L5-20R
MP6
MR3-3 MR3-3
M R
-1
M R
-1
MR3-2MR3-2
MR3-9
MR3-19 MR3-1
R1-32
AC
R1-22
OH-110B
P1-7,9,11
OH-110C
P1-13,15,17
M M
R1-15
FPD
R1-15
FPD
R1-23
ATS1
D30 D30
M A
T C
H L
IN
E
A
E P
CR3-4
CR3-4
MR3-23
MR3-17
MR3-18
MR3-12
CR3-1
MR3-7
MR3-27
GFI
WPIU
MR1-19,21,23
MR1-14
GENERATOR EG-1 (SEE SHEET
ES402 FOR EXACT LOCATION)
MR3-4
MR3-7
CR3-6,8
L6-30R
R1-13
+36" AFF
R1-13
+36" AFF
R1-25
+36" AFF
R1-25
+36" AFF
MR1-7
EP MR1-7
EP CR3-2CR3-13
MR3-15
MR3-14
C R
-1
C R
-1
C R
-1
C R
-2
C R
-2
C R
-2
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
A M
A S
H E
K E
L
A F
D R
A W
IN
G
C O
D E
E L L S
W O
R T
H A
IR
F
O R
C E
B A
S E
S
D
P N
F X
B M
F
Y
B -2
L
O W
O B
S E
R V
A B
L E
-B
A Y
R E
S T
O R
A T
IO
N
F A
C
IL
IT
Y
A P
R
IL
A D
V E
R T
IS
E
M E
N T
D
E S
IG
N
A B C D
E F
KEY PLAN
NOT TO SCALE
W F
-2 -R
-0
EP105
P O
W E
R P
L A
N
A R
E A
E
M H
A R
A L S
O N
Z M
A T
H E
W S
P O
'G O
R M
A N
0 4' 8' 16'
SCALE: 1/8" = 1'-0"
A1
POWER PLAN - AREA E
GENERAL NOTES:
1. SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES,
LEGEND, AND ABBREVIATIONS.
2. ALL OFFICES, CONFERENCE ROOMS, AND BREAK
ROOMS ARE REQUIRED TO HAVE AUTOMATICALLY
SWITCHED RECEPTACLES PER ASHRAE 90.1. SEE
LIGHTING CONTROL MATRIX ON DRAWING EL602 FOR
SPACES WITH THIS REQUIREMENT.
KEYED NOTES:
MOUNT RECEPTACLE INSIDE TELECOMMUNICATIONS
CABINET. SEE TELECOMMUNICATIONS SHEETS FOR
CABINET LOCATION.
MOUNT DUPLEX RECEPTACLES LOCATED WITHIN
THIS ROOM IN SURFACE MOUNTED RACEWAY.
ROUTE POWER CONDUCTORS IN SURFACE MOUNTED
RACEWAY. SEE DETAIL A1 ON SHEET TN511 FOR
SURFACE MOUNTED RACEWAY DETAILS.
POWER FOR MECHANICAL EQUIPMENT CONTROL
PANEL. COORDINATE WITH FINAL LOCATION OF
PANEL.
POWER FOR "CLEAN IN PLACE" SKID CONTROL
PANEL.
POWER FOR RO TRANSFER PUMP SKID CONTROL
PANEL.
POWER FOR CARBON FILTER TANKS.
POWER FOR SUMP PUMP CONTROL PANEL.
POWER FOR EMERGENCY SHOWER. COORDINATE
WITH FINAL LOCATION OF EMERGENCY SHOWER.
RECEPTACLE FOR MECHANICAL EQUIPMENT
SOLENOID VALVE. RECEPTACLE TO BE MOUNTED
ABOVE ROOM CEILING LID AND ADJACENT TO
MECHANICAL EQUIPMENT.
POWER FOR ACS/IDS SYSTEM.
POWER FOR GENERATOR AUXILIARY SYSTEMS.
ALL CONDUIT, BOXES, AND DEVICES MUST BE
SURFACED MOUNTED ON THE INTERIOR AND
EXTERIOR WALLS OF THIS ROOM. SEE DETAILS ON
EG503 FOR WALL PENETRATIONS IN THIS ROOM.
POWER FOR BREATHING AIR ALARM PANEL.
POWER FOR BREATHING AIR ALARM STROBE.
COORDINATE WITH FINAL LOCATION OF STROBE.
A
M -0
D
E S
IG
N
I S
S U
E D
F O
R P
R
IC
IN
G
A P
R
A
M E
N D
M E
N T
M A
Y
A
M E
N D
M E
N T
M A
Y
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
M
M
M
9 9.2 10 10.2 11 13 14 15 15.2
J
H
MATCH LINE
A1/ EP133
MATCH LINE
A1/ EP132
M A
T C
H L
IN
E
A
E P
CU-101
CR2-4,6
VAV-106
MR1-16
VAV-107
MR1-10
VAV-108
MR1-16
VAV-105
MR1-16
VAV-112
MR1-16
UH-106
MR1-6SF-101
MR1-17
CRAC-102
CR2-15,17,19
TRAINING ROOM
VEST
OFFICE
OFFICE
MOTHERS ROOM
COMM
FABRICATION
FIRE PUMP
VEST
STORAGE
TOOL / SUPPORT
EQUIP
HAZMAT/ LO
STORAGE
DEMIL
MAU-101
MP1-25,27,29
EF-102
MR1-37 EF-101
MP3-37,39,41
UH-107
MR1-6
UH-108
MR1-6
VAV-113
MR1-16
CUH-104
MR1-9
CUH-105
MR1-9
ACU-101
CU-102
R5-10,12
CP-102
MR1-39
CORRIDOR
C O
R R
ID
O
R
CORRIDOR
PLAN
NORTH
US Army Corps of Engineers ®
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
A M
A S
H E
K E
L
A F
D R
A W
IN
G
C O
D E
E L L S
W O
R T
H A
IR
F
O R
C E
B A
S E
S
D
P N
F X
B M
F
Y
B -2
L
O W
O B
S E
R V
A B
L E
-B
A Y
R E
S T
O R
A T
IO
N
F A
C
IL
IT
Y
A P
R
IL
A D
V E
R T
IS
E
M E
N T
D
E S
IG
N
A B C D
E F
KEY PLAN
NOT TO SCALE
W F
-2 -R
-0
EP136
H V
A C
P O
W E
R P
L A
N
A R
E A
F
M H
A R
A L S
O N
Z M
A T
H E
W S
P O
'G O
R M
A N
SCALE: 1/8" = 1'-0"
C1
HVAC POWER PLAN - AREA F
0 4' 8' 16'
GENERAL NOTES:
1. SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES,
LEGEND, AND ABBREVIATIONS.
2. SEE SHEET SHEET EP710 AND EP711 FOR
MECHANICAL EQUIPMENT CONNECTION SCHEDULES.
KEYED NOTE:
NOT USED.
POWERED FROM CU-101. COORDINATE RACEWAY
BETWEEN UNITS WITH EQUIPMENT INSTALLER. PROVIDE
MOTOR RATED SWITCH FOR INDOOR UNIT.
A
M -0
D
E S
IG
N
I S
S U
E D
F O
R P
R
IC
IN
G
A P
R
A
M E
N D
M E
N T
M A
Y
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
A M
A S
H E
K E
L
A F
D R
A W
IN
G
C O
D E
E L L S
W O
R T
H A
IR
F
O R
C E
B A
S E
S
D
P N
F X
B M
F
Y
B -2
L
O W
O B
S E
R V
A B
L E
-B
A Y
R E
S T
O R
A T
IO
N
F A
C
IL
IT
Y
A P
R
IL
A D
V E
R T
IS
E
M E
N T
D
E S
IG
N
W F
-2 -R
-0
EP701
P A
N E
L B
O A
R D
S C
H E
D U
L E
S
M H
A R
A L S
O N
Z M
A T
H E
W S
P O
'G O
R M
A N
DEMAND WITH EXPANSION: 154 A
TOTAL ESTIMATED DEMAND... 128 A
TOTAL CONNECTED CURRENT: 153 A
TOTAL ESTIMATED DEMAND LOAD: 46195 VA
TOTAL CONNECTED LOAD: 54977 VA
PANEL TOTALS
TOTAL LOAD: 18091 VA 19961 VA 16925 VA
23 -- -- SPACE -- 0 0 -- -- -- -- 24
21 -- -- SPACE -- 0 0 -- -- -- -- 22
19 -- -- SPACE -- 0 0 WIRING PER MANUF. SPD* 3 30 20
17 -- -- SPACE -- 0 0 -- SPACE -- -- 18
15 -- -- SPACE -- 0 0 -- SPACE -- -- 16
13 -- -- SPACE -- 0 0 -- SPACE -- -- 14
11 -- -- -- -- 10911 0 -- SPACE -- -- 12
9 -- -- -- -- 11697 0 -- SPACE -- -- 10
7 150 3 CR3 150-4 11271 0 -- SPACE -- -- 8
5 -- -- -- -- 6014 0 -- SPACE -- -- 6
3 -- -- -- -- 8264 0 -- SPACE -- -- 4
1 100 3 CR2 4-#1/0AWG, #6AWG GND IN 1-1/2"C 6820 0 -- SPACE -- -- 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B C WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
*SIZE PER MANUFACTURER'S RECOMMENDATIONS.
NOTES:
ENCLOSURE: NEMA 1 MCB RATING: 250 A
MOUNTING: SURFACE WIRES: 4 MAINS RATING: 250 A
SUPPLY FROM: CT1 PHASE: 3 MAINS TYPE: MCB
LOCATION: ELEC 108 VOLTAGE: 208Y/120V A.I.C. RATING: 10000
PANELBOARD: CR1
DEMAND WITH EXPANSION: 63 A
TOTAL ESTIMATED DEMAND... 53 A
TOTAL CONNECTED CURRENT: 59 A
TOTAL ESTIMATED DEMAND LOAD: 18930 VA
TOTAL CONNECTED LOAD: 21098 VA
PANEL TOTALS
TOTAL LOAD: 6820 VA 8264 VA 6014 VA
29 -- -- -- -- 0 0 -- -- -- -- 30
27 30 2 SPARE 0 0 -- -- -- -- 28
25 20 1 SPARE 0 0 WIRING PER MANUF, SPD* 3 30 26
23 20 1 SPARE 0 0 -- SPACE -- -- 24
21 20 1 SPARE 0 0 -- SPACE -- -- 22
19 -- -- -- -- 1810 0 -- SPACE -- -- 20
17 -- -- -- -- 1810 0 -- SPACE -- -- 18
15 30 3 CRAC-102 FABRICATION 123 30-3 1810 0 -- SPACE -- -- 16
13 -- -- -- -- 750 750 -- -- -- -- 14
11 30 2 RECEPT RACK RM 122 30-2 750 750 30-2 RECEPT RACK RM 122 2 30 12
9 20 1 RECEPT RACK RM 122 20-2 1500 750 -- -- -- -- 10
7 20 1 RECEPT COMM 122 20-2 720 750 30-2 RECEPT RACK RM 122 2 30 8
5 20 1 SPARE 0 2704 -- -- -- -- 6
3 20 1 RECEPT RACK RM 122 20-2 1500 2704 40-2 CU-101 EXT 2 40 4
1 20 1 RECEPT RACK RM 122 20-2 1500 540 20-2 RECEPT COMM 122 1 20 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B C WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
*SIZE PER MANUFACTURER'S RECOMMENDATIONS.
NOTES:
ENCLOSURE: NEMA 1 MCB RATING: 100 A
MOUNTING: SURFACE WIRES: 4 MAINS RATING: 100 A
SUPPLY FROM: CR1 PHASE: 3 MAINS TYPE: MCB
LOCATION: COMM 122 VOLTAGE: 208Y/120V A.I.C. RATING: 10000
PANELBOARD: CR2
DEMAND WITH EXPANSION: 96 A
TOTAL ESTIMATED DEMAND... 80 A
TOTAL CONNECTED CURRENT: 94 A
TOTAL ESTIMATED DEMAND LOAD: 28894 VA
TOTAL CONNECTED LOAD: 33879 VA
PANEL TOTALS
TOTAL LOAD: 11271 VA 11697 VA 10911 VA
29 20 1 SPARE 0 0 -- -- -- -- 30
27 20 1 SPARE 0 0 -- -- -- -- 28
25 20 1 RECEPT CHRGNG CABINET RM 112 20-2 1800 0 WIRING PER MANUF. SPD* 3 30 26
23 20 1 RECEPT CHRGNG CABINET RM 112 20-2 1800 0 SPARE 1 20 24
21 20 1 RECEPT CHRGNG CABINET RM 112 20-2 1800 0 SPARE 1 20 22
19 20 1 RECEPT CHRGNG CABINET RM 112 20-2 1800 0 SPARE 1 20 20
17 20 1 RECEPT CHRGNG CABINET RM 112 20-2 1800 0 SPARE 1 20 18
15 20 1 RECEPT CHRGNG CABINET RM 112 20-2 1800 36 20-2 BEACON LTG RM 112 1 20 16
13 20 1 JB ACS/IDS SYSTEM RM 112 20-2 180 4234 -- -- -- -- 14
11 -- -- -- -- 1607 4234 -- -- -- -- 12
9 -- -- -- -- 1607 4234 60-3 CRAC-101 RM 112 3 60 10
7 20 3 CU-103 EXT 20-3 1607 750 -- -- -- -- 8
5 20 1 RECEPT RM 112 20-2 720 750 30-2 RECEPT CHRGNG CABINET RM 112 2 30 6
3 20 1 RECEPT CABINET RM 112 20-2 1500 720 20-2 RECEPT RM 112 1 20 4
1 20 1 JB ACS/IDS SYSTEM RM 112 20-2 180 720 20-2 RECEPT RM 112 1 20 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B C WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
*SIZE PER MANUFACTURER'S RECOMMENDATIONS.
NOTES:
ENCLOSURE: NEMA 1 MCB RATING: 150 A
MOUNTING: SURFACE WIRES: 4 MAINS RATING: 250 A
SUPPLY FROM: CR1 PHASE: 3 MAINS TYPE: MCB
LOCATION: SECURE OFFICE 112 VOLTAGE: 208Y/120V A.I.C. RATING: 10000
PANELBOARD: CR3
DEMAND WITH EXPANSION: 35 A
TOTAL ESTIMATED DEMAND... 30 A
TOTAL CONNECTED CURRENT: 30 A
TOTAL ESTIMATED DEMAND LOAD: 7080 VA
TOTAL CONNECTED LOAD: 7080 VA
PANEL TOTALS
TOTAL LOAD: 3580 VA 3500 VA
23 20 1 SPARE 0 0 -- SPACE -- -- 24
21 20 1 SPARE 0 0 -- SPACE -- -- 22
19 20 1 SPARE 0 0 -- SPACE -- -- 20
17 20 1 SPARE 0 0 -- SPACE -- -- 18
15 20 1 SPARE 0 0 -- SPACE -- -- 16
13 20 1 JB FIRE ALARM BEACON RM 132 2-#6AWG, #6AWG GND IN 3/4"C 540 0 -- SPACE -- -- 14
11 20 1 JB AMP PNL RM 200 20-2 500 0 -- SPACE -- -- 12
9 20 1 JB RSFACU PNL RM 155 20-2 500 540 2-#10AWG, #10AWG GND IN 3/4"C JB FIRE ALARM BEACON RM 102 1 20 10
7 20 1 JB RSFACU BATTERY CHGR RM 124 20-2 500 500 20-2 JB NAC PNL RM 200 1 20 8
5 20 1 JB FACU/ACU PNL RM 155 20-2 500 500 20-2 JB NAC PNL RM 124 1 20 6
3 20 1 JB FIRE ALARM AMP RM 102 2-#8AWG, #8AWG GND IN 3/4"C 1000 1000 2-#6AWG, #6AWG GND IN 3/4"C JB FIRE ALARM AMP RM 132 1 20 4
1 20 1 JB AMP PNL RM 124 2-#10AWG, #10AWG GND IN 3/4"C 500 500 2-#10AWG, #10AWG GND IN 3/4"C JB FAC PNL RM 155 1 20 2
# BKR P LOAD SERVED WIRE / GROUND / CONDUIT A B WIRE / GROUND / CONDUIT LOAD SERVED P BKR #
NOTES:
ENCLOSURE: NEMA 1 MCB RATING: 60 A
MOUNTING: SURFACE WIRES: 3 MAINS RATING: 100 A
SUPPLY FROM: FT1 PHASE: 1 MAINS TYPE: MCB
LOCATION: ELEC 108 VOLTAGE: 240/120V A.I.C. RATING: 10000
PANELBOARD: FR1
SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES, LEGEND,
AND ABBREVIATIONS.
CONVERT WIRE SIZE TO #10AWG PRIOR TO TERMINATING ON A
120V, 20A WIRING DEVICE IF THE WIRE SIZE INDICATED IS
LARGER THAN WHAT THE 120V, 20A WIRING DEVICE CAN
ACCEPT.
1.
2.
GENERAL NOTES:
SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES, LEGEND,
AND ABBREVIATIONS.
CONVERT WIRE SIZE TO #10AWG PRIOR TO TERMINATING ON A
120V, 20A WIRING DEVICE IF THE WIRE SIZE INDICATED IS
LARGER THAN WHAT THE 120V, 20A WIRING DEVICE CAN
ACCEPT.
1.
2.
GENERAL NOTES:
A
M -0
D
E S
IG
N
I S
S U
E D
F O
R P
R
IC
IN
G
A P
R
A
M E
N D
M E
N T
M A
Y
SHEET ID
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
N
S A
S C
IT
Y
D
IS
T R
IC
T
E
T
H S
T R
E E
T K
A N
S A
S C
IT
Y
M
O
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
N
3 5 7 9 11 13 15 17 19
L
J
G
E
C
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
2 4 6 8 10 12 14 16 18 20
P
M
K
H
F
D
B
W
A R
D P
A R
K W
A Y
K
A N
S A
S C
IT
Y
M
O
A M
A S
H E
K E
L
A F
D R
A W
IN
G
C O
D E
E L L S
W O
R…
This is the start of the file's text. The full file is on GovTribe.