Am_0005-Drawings.pdf

PDF 8 MB Posted

Attached to
B-21 Low-Observable Restoration Facility (LO Hangar), Ellsworth AFB, SD
Solicitation number
W9128F21R0024
Issued by

About this file

This solicitation package includes plans and specifications for the construction of a B-21 Low-Observable Restoration Facility at Ellsworth Air Force Base in South Dakota. The project involves building a two-bay hangar with associated mechanical, electrical, plumbing, and communications systems. Key requirements include constructing concrete foundations, erecting structural steel framing, installing metal wall and roof panels, and completing interior finishes. Electrical work comprises installing underground ductbanks and manholes for power and communications, as well as overhead distribution systems and panelboards to supply lighting, receptacles, and equipment. Bids are due by April 2021, with construction to be completed in multiple phases through 2022.

View the file

Other files

File Type Posted
Am_0010-Drawing.pdf PDF
Am_0009.pdf PDF
Am_0010.pdf PDF
Am_0008.pdf PDF
Appendix D.pdf PDF
Am_0008-Drawings.pdf PDF
Am_0007-Drawings.pdf PDF
Am_0007.pdf PDF
Am_0006.pdf PDF
Am_0006-Drawings.pdf PDF
Am_0005.pdf PDF
Am_0004.pdf PDF
EL91_MM_I_RVT19_G_ADVERTISEMENT_100_DESIGN_VOL1_Part-a.pdf PDF
EL91_MM_I_RVT19_G_ADVERTISEMENT_100_DESIGN_VOL1_Part-b.pdf PDF
28BW_COVID_Travel_Risk_Matrix_v7_04_May_21.xlsx XLSX spreadsheet
W9128F-21-R-0024_Specs.pdf PDF
EL91_MM_I_RVT19_G_ADVERTISEMENT_100_DESIGN_VOL3.pdf PDF
EL91_MM_I_RVT19_G_ADVERTISEMENT_100_DESIGN_VOL4.pdf PDF
EL91_MM_I_RVT19_G_ADVERTISEMENT_100_DESIGN_VOL2.pdf PDF
Am_0003_W9128F21R0024.pdf PDF
Am_0004-Drawings.pdf PDF
SD27.pdf PDF
Am_0002.pdf PDF
Am_0001.pdf PDF
Appendix C - Dock 60 by FMG Dec2020.zip ZIP file
Attachment A - Data Summary Tables (pdf and CD).zip ZIP file
Attachment C - Analytical Data_J15425-1 Std_Tal_L4 Final Report.pdf PDF
Attachment C - Analytical Data_J14884-1 Std_Tal_L4 Final Report.pdf PDF
Appendix C - 60 ROW by FMG Dec2020.zip ZIP file
Attachment C - Analytical Data_J15666-1 Std_Tal_L4 Final Report.pdf PDF
Attachment C - Analytical Data_J14679-1 Std_Tal_L4 Final Report.pdf PDF
EL91_B-21_LO_95_SUBMITTAL_ DRAWINGS_VOL1.pdf PDF
Attachment C - Analytical Data_J15264-1 Std_Tal_L4 Final Report.pdf PDF
Appendix C - Dock 61 by FMG Dec2020.zip ZIP file
Attachment D - SEDDs (CD only).zip ZIP file
Attachment C - Analytical Data_J15965-1 Std_Tal_L4 Final Report.pdf PDF
Attachment C - Analytical Data_J14982-1 Std_Tal_L4 Final Report.pdf PDF
EL91_B-21_LO_95_SUBMITTAL_ DRAWINGS_VOL3.pdf PDF
Appendix C - Dock 62 by FMG Dec2020.zip ZIP file
W9128F-21-R-0024_Specs (2).pdf PDF
EL91_B-21_LO_95_SUBMITTAL_ DRAWINGS_VOL2.pdf PDF
Attachment C - Analytical Data_J15285-1 Std_Tal_L4 Final Report.pdf PDF
Appendix C - Dock 63 by FMG Dec2020.zip ZIP file
Attachment B - ADR Summary Reports (pdf and CD).zip ZIP file
EL91_B-21_LO_95_SUBMITTAL_ DRAWINGS_VOL4.pdf PDF
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REMARKS:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

AIR SHOWER. DOOR, FRAME & WALL SYSTEM PROVIDED

BY SELECTED MANUFACTURER

MECHANICAL ROOM EXTERIOR ACCESS DOOR. ACCESS

FROM INTERIOR ONLY

MANUALLY OPERATED OVERHEAD COILING DOOR /

SECURITY SHUTTER

PLENUM ACCESS DOOR

X-10 LOCK DOOR & FRAME ASSEMBLY

180 DEGREE HINGE DOORS

CARD READER

EMERGENCY EXIT ONLY

ACCESSIBLE FROM SECURE SIDE ONLY. NO DOOR

HARDWARE ALLOWED ON HANGAR SIDE

ACCESSIBLE FROM HANGAR SIDE ONLY. NO DOOR

HARDWARE ALLOWED ON ROOM 153 SIDE

MAN DOOR BY HANGAR DOOR SUPPLIER

NOT USED

MOTORIZED OVERHEAD SECTIONAL DOOR - INSULATED

DOOR GENERAL NOTE:

1. REFER TO SECTION 08 34 73 FOR ALL STC RATED DOORS

SL

A

SCHEDULE

DOOR PER A

B

S C

H E

D U

L E

D O

O R

P E

R

A

SCHEDULE

DOOR PER

A

B

S C

H E

D U

L E

D O

O R

P E

R

D O

O R

P E

R S

C H

E D

U L E

D A

D O

O R

P E

R S

C H

E D

U L E

E C

B

SCHEDULE

DOOR PER

SCHEDULE

DOOR PER

D

A A

OH

D O

O R

P E

R S

C H

E D

U L E

DOOR PER SCHEDULE

F

1 2

OS

D O

O R

P E

R S

C H

E D

U L E

DOOR PER SCHEDULE

A

SCHEDULE

DOOR PER A

B

S C

H E

D U

L E

D O

O R

P E

R D

A

LOUVER

GLASS TYPES:

REFERENCE SPECIFICATION FOR GLASS TYPES

1 CLEAR LAMINATED (1/4")

2 FIRE RATED. FIRE RATING TO MATCH

DOOR FIRE RATING

3 TINTED AND LOW E COATING

INSULATED GLASS (1-1/4")

4 CLEAR INSULATED GLASS (1-1/4")

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

K

A N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

A-601

D O

O R

S C

H E

D U

L E

D

O O

R

F R

A M

E T

Y P

E S

T .K

IM

J .C

O B

L E

R

P .W

A L T

E R

S

DOOR SCHEDULE

DOOR

NUMBER

DOOR FRAME

FIRE

ASSEMBLY

RATING STC

DETAIL

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL TYPE MATERIAL HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

144A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 50.0

144B - 3' - 0" 7' - 0" F HM 7.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 49.0

145A - 3' - 0" 7' - 0" F HM 1.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 48.0

147A - 3' - 0" 7' - 0" F HM 1.1 HM - - K6 / A-621 F6 / A-621 A6 / A-621 46.0

147B - 3' - 0" 7' - 0" F HM 7.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 49.0

148A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 15.0

149A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 42.0 7

150A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 39.0

151A - 3' - 0" 7' - 0" F-IN MAD 1.2 MAD - STC-50 K6 / A-621 F6 / A-621 A6 / A-621 32.0 5, 7

151B - 3' - 0" 7' - 0" F-IN MAD 1.2 MAD - STC-50 K6 / A-621 F6 / A-621 A6 / A-621 28.0 7

151C PR. 3' - 0" 7' - 0" F-IN MAD 1.2 MAD 45 MIN STC-50 K6 / A-621 F6 / A-621 A6 / A-621 37.0 9

151D - 3' - 0" 7' - 0" F-IN MAD 1.2 MAD - STC-50 K6 / A-621 F6 / A-621 A6 / A-621 26.1 8

152A - 3' - 0" 7' - 0" F - 1.1 - - - RE: MFR RE: MFR RE: MFR 56.0 1

152B - 3' - 0" 7' - 0" F - 1.1 - - - RE: MFR RE: MFR RE: MFR 56.0 1

153A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 26.0 8

153B PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 32.0

153C PR. 4' - 0" 8' - 0" F-IN HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 36.1 10

154A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 7.0 8

155B PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 40.0

156A PR. 3' - 0" 7' - 0" F HM 1.2 - 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 31.0 6

157A PR. 3' - 0" 7' - 0" SL-IN AL 2.1 AL - - J11 / A-622 D11 / A-622 A11 / A-622 1.0

157B PR. 3' - 0" 7' - 0" SL-IN-C AL 1.1 AL - - K6 / A-622 F6 / A-622 A6 / A-622 20.0

158A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 27.0

159A PR. 3' - 0" 8' - 4" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 11.0

SECOND FLOOR

200A PR. 4' - 0" 8' - 0" F-IN HM 1.2 HM - - K1 / A-622 F1 / A-622 A1 / A-622 14.0 2

201A - 3' - 0" 7' - 0" F HM 1.2 HM 60 MIN - K6 / A-621 K1 / A-621 A6 / A-621 51.0

202A - 3' - 0" 7' - 0" F HM 1.2 HM 60 MIN - K6 / A-621 F6 / A-621 A6 / A-621 51.0

T.O. PLENUM DECKING

201B - 3' - 0" 7' - 0" F HM 1.1 HM 45 MIN - K1 / A-621 F1 / A-621 A1 / A-621 52.0 4

202B - 3' - 0" 7' - 0" F HM 1.1 HM 45 MIN - K1 / A-621 F1 / A-621 A1 / A-621 52.0 4

DOOR SCHEDULE

DOOR

NUMBER

DOOR FRAME

FIRE

ASSEMBLY

RATING STC

DETAIL

HARDWARE

SET REMARKS

SIZE

TYPE MATERIAL TYPE MATERIAL HEAD JAMB SILL

PAIR

DOOR WIDTH HEIGHT

GROUND FLOOR

101A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 6.0 8

101B - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - - - - 16.0 11

101C - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - - - - 16.0 11

101D - 3' - 0" 7' - 0" F-IN HM 1.2 HM 45 MIN - K16 / A-621 F16 / A-621 A16 / A-621 5.0 8

102A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 6.0 8

102B - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 6.0 8

102C - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 18.0 8

102D - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 18.0 8

102E - 3' - 0" 7' - 0" F-IN HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 21.0 5, 7

103A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 24.0 4

103B - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 24.0 4

104A - 3' - 0" 7' - 0" F HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 19.0 8

105A - 3' - 0" 7' - 0" F HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 19.0 8

106A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 2.0 8

107A PR. 3' - 0" 8' - 4" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 9.0

108A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 11.0

108B - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 12.0 8

109A PR. 3' - 0" 7' - 0" F HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 31.0 6

110B 10' - 0" 12' - 0" OS-IN STL STL - - D1 / A-623 A10 / A-623 A1 / A-623 54.0 13

110C 10' - 0" 12' - 0" OS-IN STL STL - - D1 / A-623 A10 / A-623 A1 / A-623 54.0 13

110D - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 13.0

110E - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 13.0

112A - 3' - 0" 7' - 0" F MAD 1.2 MAD - STC-50 K6 / A-621 F6 / A-621 A6 / A-621 22.0 5, 7

112B - 3' - 0" 7' - 0" F MAD 1.2 MAD - STC-50 K6 / A-621 F6 / A-621 A6 / A-621 28.0 7

114A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 41.0

115A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 4.0 8

115B PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 30.0

117A PR. 3' - 0" 7' - 0" SL-IN AL 2.1 AL - - J11 / A-622 D11 / A-622 A11 / A-622 1.0

117B PR. 3' - 0" 7' - 2" SL-IN-C AL 1.1 AL - - K6 / A-622 F6 / A-622 A6 / A-622 20.0 7

118A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 43.0

119A - 3' - 0" 7' - 0" F HM 1.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 41.0

120A - 3' - 0" 7' - 0" F HM 1.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 41.0

121A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 45.0

122A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 44.0 7

123A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 32.0

123B PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 32.0

124A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 8.0

125A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 32.1 7

125C PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 32.0

125D 10' - 0" 10' - 0" OS-IN STL STL - - D1 / A-623 A10 / A-623 A1 / A-623 54.0 13

125E 9' - 0" 4' - 0" OH-S AL AL - - K16 / A-623 G16 / A-623 C16 / A-623 54.0 3

125F 9' - 0" 4' - 0" OH-S AL AL - - K16 / A-623 G16 / A-623 C16 / A-623 54.0 3

126A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 F11 / A-621 35.0 7

126B PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 F11 / A-621 34.0

126C PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A11 / A-621 10.0 8

127A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 25.0

127B PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 10.0 8

128B - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 2.0 8

129A - 3' - 0" 7' - 0" F HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 19.0 8

130C - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 24.0 4

130D - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 24.0 4

131A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 6.0 8

132A - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F16 / A-621 A6 / A-621 18.0 8

132B - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 18.0 8

132C - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 6.0 8

132D - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 6.0 8

132E PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM 45 MIN - K6 / A-621 F6 / A-621 A6 / A-621 29.0 5, 7

133A - 3' - 0" 7' - 0" F-IN HM 1.2 HM 45 MIN - K16 / A-621 F16 / A-621 A16 / A-621 5.0 8

133B - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - - - - 16.0 11

133C - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - - - - 16.0 11

133D - 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K16 / A-621 F16 / A-621 A16 / A-621 6.0 8

134A - 3' - 0" 7' - 0" F-IN HM 1.2 HM 60 MIN - K16 / A-621 F16 / A-621 A16 / A-621 3.0

134B - 3' - 0" 7' - 0" F-IN HM 1.2 HM 60 MIN - K6 / A-621 F6 / A-621 A6 / A-621 23.0 8

135A - 3' - 0" 7' - 0" F-IN HM 1.2 HM 60 MIN - K16 / A-621 F16 / A-621 A16 / A-621 3.0

135B - 3' - 0" 7' - 0" F-IN HM 1.2 HM 60 MIN - K6 / A-621 F6 / A-621 A6 / A-621 23.0 8

136A - 3' - 0" 7' - 0" F-IN MAD 1.2 MAD - STC-50 K6 / A-621 F6 / A-621 A6 / A-621 33.0 5, 7

136B PR. 4' - 0" 8' - 0" F-IN MAD 1.2 MAD 45 MIN STC-50 K6 / A-621 F6 / A-621 A6 / A-621 36.0 9

136C - 3' - 0" 7' - 0" F-IN MAD 1.2 MAD - STC-50 K6 / A-621 F6 / A-621 A6 / A-621 28.0 7

137A - 3' - 0" 7' - 0" F - 1.1 - - - RE: MFR RE: MFR RE: MFR 56.0 1

137B - 3' - 0" 7' - 0" F - 1.1 - - - RE: MFR RE: MFR RE: MFR 56.0 1

138A PR. 3' - 0" 7' - 0" F-IN HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 38.0

139A - 3' - 0" 7' - 0" F HM 1.1 HM - - K6 / A-621 F6 / A-621 A6 / A-621 46.0

140A - 3' - 0" 7' - 0" F HM 7.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 47.0

141A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 46.0

142A - 3' - 0" 7' - 0" F HM 7.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 48.0

142B - 3' - 0" 7' - 0" F HM 1.1 HM - - K1 / A-621 F1 / A-621 A1 / A-621 49.0

143A - 3' - 0" 7' - 0" F HM 1.2 HM - - K6 / A-621 F6 / A-621 A6 / A-621 53.0

DOOR AND FRAME LEGEND

MAD METAL ACOUSTICAL DOOR

MATERIAL

AL ALUMINUM

HM HOLLOW METAL

STL STEEL

SIZE

- SINGLE DOOR

PR PAIR OF DOORS

*REFERENCE DOOR OR FRAME SPECIFICATION

**FIELD APPLY PER PAINT SPECIFICATION FOR

APPLICABLE SUBSTRATE AND EXPOSURE.

(DOOR FRAME)

TYPE A B

1.1 2" 2"

1.2 2" 4"

(FRAME WITH TRANSOM)

TYPE A B D #

2.1 2" 2" 16" 3

(FLUSH PANEL)

TYPE DESCRIPTION

F-IN FLUSH PANEL INSULATED

F FLUSH PANEL

(OVERHEAD)

TYPE DESCRIPTION

OH-S COILING SECURITY SHUTTER

(SPLIT LITE)

TYPE DESCRIPTION A B C D E #

SL-IN SPLIT LITE INSULATED 6" 10" 24" 6" 6" 3

SL-IN-C SPLIT LITE INSULATED 6" 10" 24" 6" 6" 4

(OVERHEAD SECTIONAL)

TYPE DESCRIPTION

OS-IN INSULATED OVERHEAD

SECTIONAL DOOR

(FRAME WITH LOUVERED TRANSOM)

TYPE A B D

7.1 2" 2" 12"

A

M -0

D

E S

IG

N

I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

J7

AG004

J1

AG004

100' - 0"

8' - 0" 3' - 4" 2' - 8"

1' - 4" 4' - 0" 3' - 4" 4' - 0" 1' - 4"

3'-0" X 7'-0" HOLLOW

METAL DOOR (PAINT

FINISH) WITH HOLLOW

METAL FRAME TYPE 1.2

F16

A-621

1' - 4" 6' - 8" 4' - 8"

1' - 4"

F1

A-622

8" NOM CMU WALL

K15

A-504

G1

A-521

K8

A-641

14' - 0"

ROUND PIPE /

CONDUIT

EXPOSE WALL

CONSTRUCTION

FOR INSPECTION

EXPOSE WALL

CONSTRUCTION

FOR INSPECTION

CMU

MORTAR

COLOR

A&B

CMU

MORTAR

COLOR B

CMU

MORTAR

COLOR A

J7

AG004

J1

AG004

F11

A-503

A1

A-671

F16

A-502

A13

A-521 L1

A-521

A15

A-504

A5

A-504

A11

A-505

8" NOM

CMU WALL

(1) LAYERS 5/8" TYPE "X"

GYPSUM BOARD EACH SIDE ON

6" STRUCTURAL STUDS WITH

INSULATION

3"

2' - 5" 8' - 8" 2' - 8"

14' - 0"

7' - 0" 7' - 0"

RECTANGULAR

MECHANICAL DUCT

ROUND

MECHANICAL DUCT

14' - 0"

PREFINISHED

ALUMINUM

LOUVER

J7

AG004

J1

AG004

10"x10" GUTTER

SNOW / ICE GUARD

STANDING SEAM

METAL ROOF

ROUND MECHANICAL

DUCT PENETRATION

RECTANGULAR

MECHANICAL DUCT

PENETRATION

WALL PENETRATIONS

BELOW PENETRATION

A9

A-571

A9

A-571

SIMSIM

F16

A-502

K11

A-502

F1

A-503A1

A-622

K1

A-622

A1

A-573

SIM

A16

A-621

K16

A-621

G1

A-573

J1

A-510

MECHANICAL DUCT

ROOF PENETRATION

PIPE PENETRATION

3.3 3.52

3.54

3.10

3.10

3.50 3.1

3.7

3.8

3.14

3.5

3.23.9

6"

G1

A-641

A1

A-641

A1

A-510

A10

A-574

J1

A-510

F1

A-671

K1

A-671

A1

A-574

A1

A-510

CMU CONTROL

JOINT

MECHANICAL DUCT

ROOF PENETRATION

3.7

3.8

3.14

3.5

3.18

3.16

3.32

3.5

3.1

3.3

3.12

3.3

3.16

GENERAL SHEET NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

CONSTRUCT THE MOCK UP TO REFLECT THE WORKMANSHIP AND THE

CONSTRUCTION TECHNIQUES THAT WILL BE USED TO CONSTRUCT THE

AWARDED FACILITIES. ALL MATERIALS MUST BE REPRESENTED SO THE

ASSEMBLIES CAN BE EVALUATED BY THE CONTRACTING OFFICER.

THE COMPLETED MOCK UP WILL BE USED TO DEMONSTRATE THE

ACCEPTABLE LEVEL OF WORKMANSHIP FOR THE MATERIALS

REPRESENTED. IT WILL ALSO BE USED TO VERIFY CONSTRUCTION

TECHNIQUES AND WILL PRODUCE AN ACCEPTABLE VISUAL EFFECT FOR ALL

MATERIALS REPRESENTED ON THE PROJECT. THE MOCK UP SHALL BE

USED TO CONFIRM THE FINAL COLOR OF ALL MATERIALS. PROTECT THE

MOCK UP FROM WEATHER AND CONSTRUCTION OPERATIONS UNTIL THE

WORK HAS BEEN COMPLETED AND APPROVED. PERFORM MASONRY

CLEANING PROCEDURES ON THE MOCK UP AND OBTAIN THE APPROVAL OF

THE CONTRACTING OFFICER PRIOR TO CLEANING THE MASONRY ON THE

BUILDING. THE MOCK UP MUST REMAIN FOR THE DURATION OF THE

CONSTRUCTION PERIOD AS A REFERENCE. ONCE CONSTRUCTION IS

COMPLETE THE MOCK UP MUST BE REMOVED COMPLETELY FROM THE

SITE.

EACH TRADE MUST COMPLETE WORK ON THE MOCK UP RELATING TO

THEIR TRADE AFTER THE APPROVAL OF SHOP DRAWINGS AND

SUBMITTALS. EACH TRADE'S WORK ON THE MOCK UP MUST BE APPROVED

BY THE CONTRACTING OFFICER PRIOR TO BEGINNING WORK ON THAT

FEATURE OF WORK ON THE PERMANENT BUILDING.

SHOW FULL COLOR RANGE, TEXTURE, BOND PATTERNS AND FLASHING

DETAILS FOR ALL MATERIALS AS SHOWN ON THE MOCK UP DRAWINGS.

REFER TO THE SPECIFICATION SECTIONS FOR SUBMITTAL REQUIREMENTS

FOR ALL ITEMS SHOWN ON THE DRAWINGS.

THE ARCHITECTURAL MOCK UP MUST BE CONSTRUCTED USING DRAWINGS

ON THIS SHEET, CORRESPONDING DETAILS ON OTHER SHEETS, AND

SPECIFICATIONS FOR INFORMATION REGARDING CONSTRUCTION OF THE

MOCK UP.

MOCK UP WILL BE USED TO TEST AIR BARRIER DETAILS, CONSTRUCTION,

AND SAMPLE BLOWER DOOR AIR TIGHTNESS TEST.

CONTRACTOR SHALL ENGINEER AND CONSTRUCT THE CONCRETE FOOTING

FOR MOCK UP.

CONTRACTOR SHALL REMOVE MOCK UP AND CONCRETE FOOTING AND

DISPOSE OF MATERIALS ACCORDING TO CONSTRUCTION WASTE

MANAGEMENT PLAN.

PROVIDE 2 DIFFERENT CMU MORTAR COLORS.

COLOR A: MATCH TO GROUND FACE CMU

COLOR B: MATCH TO SPLIT FACE CMU

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D

E S

IG

N

W F

-2 -R

-0

AG004

M O

C K

U P

P L A

N S

A N

D S

E C

T

IO

N S

T .K

IM

J .C

O B

L E

R

P .W

A L T

E R

S

SCALE: 3/8" = 1'-0"

A1

MOCK UP PLAN AT 4'-0" AFF

0 2' 4' 6' SCALE: 3/8" = 1'-0"

A7

MOCK UP PLAN AT 12'-0" AFF

SCALE: 3/8" = 1'-0"

A14

MOCK UP ROOF PLAN

SCALE: 3/8" = 1'-0"

J7

MOCK UP WALL SECTION

SCALE: 3/8" = 1'-0"

J1

MOCK UP WALL SECTION

0 2' 4' 6' 0 2' 4' 6'

0 2' 4' 6' 0 2' 4' 6'

SHEET KEYNOTES

3.1 STANDING SEAM METAL ROOF PANEL - COLOR:

MANUFACTURER STANDARD COLOR MATCH TO

MEDIUM BRONZE

3.2 PREFINISHED METAL GUTTER W/ DOWNSPOUT -

COLOR MATCH TO WALL PANEL

3.3 MP-1: RIBBED INSULATED METAL WALL PANEL -

COLOR: MANUFACTURER STANDARD COLOR BEST

MATCH TO LIGHT GRAY (RE: ELEVATIONS)

3.5 8" NOMINAL CMU BLOCK (PAINTED)

3.7 4" - NOMINAL CMU VENEER (RE: ELEVATIONS)

3.8 RIGID WALL INSULATION (R-15 MIN)

3.9 MP-5: CONCEALED FASTENER METAL SOFFIT/WALL

PANEL - COLOR: MANUFACTURER STANDARD

COLOR BEST MATCH TO WHITE

3.10 INSULATED EXTERIOR PERSONNEL DOOR AND

FRAME (RE: ELEVATIONS)

3.12 PREFINISHED ALUMINUM INSULATED GLAZING &

FRAME SYSTEM

3.14 CONT. AIR BARRIER

3.16 PREFINISHED METAL WALL FLASHING (COLOR TO

MATCH ADJACENT WALL PANEL)

3.18 PREFINISHED ALUMINUM LOUVER

3.32 STUD/GYPSUM BOARD WALL (RE: PARTITION TYPE)

3.50 SNOW/ICE GUARDS

3.52 IMPACT RESISTANT GYP. BD. BOTTOM 8'-0" ON TOP

OF GLASS MAT GYP. BD.

3.54 8" COLD FORM FRAME

x

A

M -0

D

E S

IG

N

I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

JY

DT

TT

LT

LD

M

J

LD

LD

UE/UCUE/UCUE/UCUE/UCUE/UCUE/UCUE/UC

J

J

US Army Corps of Engineers ®

SHEET ID

U

M

Y

C

O R

P

O

F

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

C T

N

S O

L I C

I T

A T

I O

N

N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

E L L S

W O

R T

H

A

I

R

E

B

S

E

S

D

O M

A H

A

D

I S

T R

I C

T

C

A P

I T

O L

A

V E

N U

E

O M

A H

A

N

E

A

M

A S

H E

K

A P

R I L

E L

D

A

W I N

G

C

O D

E

A D

V E

R T

I S

E M

E N

T

D

E S

I G

N

B

L O

W

O

B S

E R

V A

B L

B

Y

S

T O

R A

T I O

N

F

A C

I L I T

Y

P N

F

X B

M

F

Y

W

A R

D

P

A R

K W

A Y

K

A N

S A

S

C

I T

Y

M

O

W F

R

A P

R

A

M

S

I G

N

I S

S U

I C

I N

G

EF401

E N

L A

R G

E

C T

R I C

A

N

T

H

O G

A N

L

M

O R

A L E

S F

O W

L E

R

B A

C H

T E

L O

G

O R

M A

N

NOTES:

1. REFER TO EF001 FOR LEGEND, GENERAL NOTES AND

ABBREVIATIONS.

F-24 DISPENSER #2

F-24 DISPENSER #1

ABOVEGROUND

STORAGE TANK (AST-1)

PUMP FP-1

FUELING ELECTRICAL RACK

FUEL MANAGEMENT

SYSTEM (FMS)

G9

EF503

J1

EF504

A1

EF504

CONTINUES TO

BUILDING 7504

SEE SHEET EF101

14 16 19

17 7 20

23 24

25 26

SCALE: 1/4" = 1'-0"

A1

ENLARGED NEW WORK

PLAN

NORTH

SCALE IN FEET

0 2' 4' 8'

SPARE CONDUIT STUB-UP AT BASE OF CANOPY COLUMN

FOR FUTURE CANOPY LIGHTING

KEYED NOTES:

A15

EF503

(TYP)

J1

EF501

F14

EF501

M A

Y

A

M E

N D

M E

G

EMERGENCY

FUEL

SHUTOFF

J

J

NEMA 3R 6"x6"x12" POWER WIREWAY.

KEYED NOTES:

J1

EMERGENCY FUEL SHUTOFF (EFSO)

SCALE: NTS

NOTES:

STAINLESS STEEL

MOUNTING SCREW

QUANTITY AND LOCATION

AS REQUIRED (TYP)

84"

AG

(MINIMUM)

LETTERS 2"

HIGH

3/4" SPACE

(TYP)

1. PAINTED ALUMINUM SIGN OF THICKNESS SUITABLE FOR APPLICATION.

2. EUROSTILE BOLD EXTENDED STYLE LETTERS.

3. COLORS: LETTERS - RED

BACKGROUND - WHITE

4. PAINT SCREW HEADS TO MATCH SIGN COLOR.

EMERGENCY

FUEL

SHUTOFF

18"

13"

A9

EFSO SIGN

SCALE: NTS

5" 2"

1/4

2"

9"

TOP OF

CONCRETE PAD

GALVANIZED C6x8.2

MEMBER

3/4" BASE PLATE

(4) 5/8" DIAMETER,

EXPANSION ANCHORS, 4"

MINIMUM EMBEDMENT

TO GROUND GRID OR

ROD AS INDICATED ON

DETAILS OR PLANS

#1/0 BOLTED GROUND CABLE.

DRILL HOLE PRIOR

TO GALVANIZING

A1

TYPICAL CONCRETE PAD FOUNDATION

SCALE: NOT TO SCALE

E1

EQUIPMENT RACK BASEPLATE

SCALE: NOT TO SCALE

EF503

E1

TYPICAL ALL

VERTICAL MEMBERS

HOT-DIPPED GALVANIZED

1-5/8" STRUT CHANNELS AS

NECESSARY (TYP

HORIZONTAL MEMEBERS)

TANK LEVEL ALARM

HORN AND STROBE

FUEL MANAGEMENT

SYSTEM

GRADE

4'-0"

MAX

(TYP)

NEMA 3R ENCLOSURE

WITH PUMP FP-1 MOTOR

STARTER

TO GROUND

GRID (TYP)

NEMA 3R RELAY

CONTROL PANEL

TO FUELING ISLAND

TO BUILDING 7504

WEATHERPROOF

EMERGENCY PHONE

ENCLOSURE

ACKNOWLEDGEMENT

ALARM SWITCH

A1

EF503

EFSO SIGN

A9

EF503

(TYP)

G9

FUELING ELECTRICAL RACK - ELEVATION

SCALE: NTS

7'0" AFG

PHOTOCELL

NEMA 3R

LIGHTING

CONTACTOR

NOTES:

1. REFER TO SHEET EF401 FOR CONDUIT TAG SCHEDULE.

NOTES:

1. REFER TO EF001 FOR LEGEND, GENERAL NOTES AND

ABBREVIATIONS.

US Army Corps of Engineers ®

SHEET ID

U

M

Y

C

O R

E

N G

I N

E E

R S

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

S U

B M

I T

T E

D

B

Y

S I Z

E

C H

E C

K E

D

B

Y

A N

S I

D

I S

S U

E

D

A T

E

C O

N T

R A

S O

L I C

I T

A T

I O

N

N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R I P

T I O

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

E L L S

W O

R T

H

A

I

R

B

S

E

S

D

O M

A H

A

D

I S

T R

I C

T

C

A P

I T

O L

A

V E

N U

E

O M

A H

A

N

E

A

M

A S

H E

K

A P

R I L

E L

A

W I N

G

C

O D

E

A D

V E

R T

I S

E M

E N

T

D

E S

I G

N

B

L O

W

O

B S

E R

V A

B

B

Y

S

T O

R A

T I O

N

F

A C

I L I T

Y

P N

F

X B

M

F

Y

W

A R

D

P

A R

K W

A Y

K

A N

S A

S

C

I T

Y

M

O

W F

R

A P

R

A

M

S

I G

N

I S

S U

I C

I N

G

EF503

E L

E C

T R

I C

A L

D

E T

A I

T

H

O G

A N

L

M

O R

A L E

S F

O W

L E

R

B A

C H

T E

L O

G

O R

M A

N

FIXTURE: AREA LED

SHIELDING: IMPACT RESISTANT CLEAR TEMPERED GLASS

HOUSING: DIE-CAST ALUMINUM

MOUNTING: ROUND POLE - 30' A.G.

REFLECTORS: DIFFUSED ALUMINUM LIGHTING SHEET

ELECTRICAL: SOLID-STATE DRIVER

FINISH: BAKED ON POLYURETHANE POWDER COAT PAINT

RATING: UL LISTED FOR WET LOCATIONS

DISTRIBUTION: TYPE AS INDICATED ON FIXTURE SCHEDULE

A15

AREA LIGHT FIXTURE - TYPE "A"

SCALE: NTS

RECP (WP, GFI)

JUNCTION BOX FOR

ATG CIRCUITS

A9

EF503

MOMENTARY RED MUSHROOM

PUSHBUTTON WITH GUARD,

HERMETICALLY SEALED

NORMALLY-CLOSED CONTACT AND

LEGEND PLATE WITH "PUSH TO STOP"

ON RED BACKGROUND. MOUNT

PUSHBUTTON, GUARD, AND LEGEND

PLATE ON FACE OF NEMA 4X BOX.

EMERGENCY

FUEL

SHUTOFF

EFSO SIGN

TOP OF

CONCRETE

HOT-DIPPED

GALVANIZED STRUT

CHANNEL MOUNTED

TO PRIDE HANGAR

WALL (TYP)

M

I N

SEE PLAN

VIEW SHEETS

FOR CONDUIT

ROUTING

NOTES:

M A

Y

A

M E

N D

M E

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

W F

-2 -R

-0

EL601

L

IG

H T

F

IX

T U

R E

S C

H E

D U

L E

J M

A J O

R S

Z M

A T

H E

W S

P O

'G O

R M

A N

1. SEE SHEETS E-001 AND E-002 FOR GENERAL

NOTES, LEGEND, AND ABBREVIATIONS.

2. LIGHT FIXTURES MUST MEET FEMP (FEDERAL

ENERGY MANAGEMENT PROGRAM) STANDARDS.

SUBMIT INFORMATION INDICATING COMPLIANCE

WITH FEMP STANDARDS.

3. INTERIOR LIGHT FIXTURES MUST BE MINIMUM 80

CRI, UON. EXTERIOR LIGHT FIXTURES MUST BE

MINIMUM 70 CRI, UON.

4. PROVIDE ALL LIGHT FIXTURES WITH DIMMING

DRIVERS CAPABLE OF DIMMING DOWN TO 1%

WITHOUT FLICKERING, NOISE, OR OTHER DEFECTS

IN LIGHTING FUNCTIONALITY, UON.

5. SEE SHEETS EL503 AND EL504 FOR LIGHTING PLATE

DETAILS.

GENERAL NOTES:LIGHT FIXTURE SCHEDULE

FIXTURE FIXTURE INFORMATION

TYPE MODIFIER TYPE

COLOR

TEMP

FIXTURE

LUMENS VOLTAGE WATTAGE DESCRIPTION MOUNTING

D1 LED 4000 K 1500 lm 277 V 18 W 6" CAN DOWNLIGHT FIXTURE WITH DIFFUSING OPTICAL LENS, SELF-FLANGED ANODIZED REFLECTORS, WHITE TRIM, SEMI-SPECULAR FINISH, AND DIMMING DRIVER.

CEILING, RECESSED

D1 E LED 4000 K 1500 lm 277 V 18 W SAME AS D1 WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT OF 900 LM. CEILING, RECESSED

D2 LED 4000 K 1500 lm 277 V 18 W SAME AS D1 BUT WET LOCATION LISTED. CEILING, RECESSED

D2 E LED 4000 K 1500 lm 277 V 18 W SAME AS D2 WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT OF 900 LM. CEILING, RECESSED

D3 LED 4000 K 500 lm 277 V 7 W SAME AS D1 BUT WITH DIFFERENT LUMEN PACKAGE. CEILING, RECESSED

E1 LED 277 V 5 W ARCHITECTURAL LED EXIT SIGN, RED LETTERS ON WHITE HOUSING, SINGLE OR DOUBLE FACE AND DIRECTIONAL

ARROWS AS INDICATED ON DRAWINGS. PROVIDE WITH MINIMUM 90 MINUTE BATTERY BACKUP.

CEILING, RECESSED

E2 LED 277 V 5 W ARCHITECTURAL LED EXIT SIGN, RED LETTERS ON WHITE HOUSING, SINGLE OR DOUBLE FACE AND DIRECTIONAL

ARROWS AS INDICATED ON DRAWINGS. PROVIDE WITH MINIMUM 90 MINUTE BATTERY BACKUP.

WALL, RECESSED

E3 LED 277 V 5 W CLASS I, DIVISION 1 EXPLOSION PROOF LED EXIT SIGN, RED LETTERS WITH ALUMINUM HOUSING. SINGLE OR DOUBLE FACE AND DIRECTIONAL ARROWS AS INDICATED ON DRAWINGS. PROVIDE WITH MINIMUM 90 MINUTE BATTERY BACKUP.

WALL, SURFACE, 8'-0" AFF

UON

FH1 LED 4000 K 15700 lm 277 V 195 W CLASS I, DIVISION 1 RATED FLOOD LIGHT, CORROSION RESISTANT COPPER-FREE ALUMINUM ALLOY BODY, END CAPS, AND LENS FRAME WITH POWDER COATED EPOXY/POLYESTER FINISH, STAINLESS STEEL EXTERNAL HARDWARE, HEAVY-DUTY GLASS LENS, AND ENCLOSED AND GASKETED.

BRACKET MOUNTED TO

STRUCTURAL RACK

L2 LED 4000 K 2300 lm 277 V 22 W 2' X 2' LIGHT FIXTURE WITH FROSTED PRISMATIC LENS, 0.125" THICK CLEAR ACRYLIC SHIELDING WITH PATTERN #12, COLD-ROLLED STEEL HOUSING, AND 92% MINIMUM AVERAGE REFLECTIVE WHITE POLYESTER POWDER COAT FINISH.

CEILING, RECESSED

L2 E LED 4000 K 2300 lm 277 V 22 W SAME AS L2 WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT OF 1200 LM. CEILING, RECESSED

L3 LED 3500 K 7000 lm 277 V 47 W CLASS I, DIVISION 1 RATED LINEAR LIGHT, 6" WIDE WITH 3'-4" NOMINAL LENGTH, CLEAR LENS, CORROSION RESISTANT

METAL HOUSING, ENCLOSED AND GASKETED.

CEILING, WALL, SURFACE,

PENDANT

L3 E LED 3500 K 7000 lm 277 V 47 W SAME AS L3 WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT OF 1000 LM. SURFACE, PENDANT

L4 LED 4000 K 2600 lm 277 V 26 W 1.5" RECESSED LINEAR SLOT LED LIGHT FIXTURE WITH 375 LUMENS PER FOOT, EXTRUDED METAL HOUSING, WITH STEEL REFLECTORS IN HIGH REFLECTIVE WHITE POWDER, ACRYLIC LENS, AND DRIVER DIMMABLE TO 1%. POWDER COAT FINISH. PROVIDE LENGTH AS REQUIRED ON DRAWINGS. PROVIDE FULLY LIT CORNERS WITH MITERED LENSES

WHEN CONNECTING ADJACENT LIGHT FIXTURES AS INDICATED ON DRAWINGS.

CEILING, RECESSED

L5E LED 4000 K 3000 lm 277 V 30 W SAME AS L4 BUT WITH DIFFERENT FIXTURE LENGTH AND WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES

MINIMUM LUMEN OUTPUT OF 1000 LM. PROVIDE LENGTH AS REQUIRED ON DRAWINGS.

CEILING, RECESSED

L6 LED 4000 K 3000 lm 277 V 30 W SAME AS L4 BUT WITH DIFFERENT FIXTURE LENGTH. PROVIDE LENGTH AS REQUIRED ON DRAWINGS. CEILING, RECESSED

L7E LED 4000 K 4800 lm 277 V 48 W SAME AS L4 BUT WITH DIFFERENT FIXTURE LENGTH AND WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES

MINIMUM LUMEN OUTPUT OF 1000 LM. PROVIDE LENGTH AS REQUIRED ON DRAWINGS.

CEILING, RECESSED

L8 LED 4000 K 5200 lm 277 V 52 W SAME AS L4 BUT WITH DIFFERENT FIXTURE LENGTH. PROVIDE LENGTH AS REQUIRED ON DRAWINGS. CEILING, RECESSED

L9 LED 4000 K 5300 lm 277 V 53 W SAME AS L4 BUT WITH DIFFERENT FIXTURE LENGTH. PROVIDE LENGTH AS REQUIRED ON DRAWINGS. CEILING, RECESSED

L10 LED 4000 K 1100 lm 277 V 14 W 4' LINEAR RECESSED WITH LIGHT FIXTURE WITH EXTRUDED METAL HOUSING, SEMI-SPECULAR REFLECTOR, AND ASYMMETRIC LENS WITH DRIVER DIMMABLE TO 1%. POWDER COAT FINISH. 275 LUMENS PER FOOT.

CEILING, RECESSED

L11 LED 4000 K 1500 lm 277 V 15 W 4' LINEAR RECESSED WITH LIGHT FIXTURE WITH EXTRUDED METAL HOUSING AND ACRYLIC LENS WITH DRIVER

DIMMABLE TO 1%. 375 LUMENS PER FOOT.

CEILING, RECESSED

L-810 INCANDESCENT 120 V 120 W L-810 OBSTRUCTION LIGHT WITH INTEGRAL PHOTOCELL. MOUNTED TO ROOF

R1 LED 4000 K 4300 lm 277 V 32 W 2' X 4' TROFFER FIXTURE WITH EXTRUDED ALUMINUM HOUSING, STEEL REFLECTORS WITH HIGH MATTE WHITE REFLECTANCE FINISH, HIGH OPTICAL GRADE ACRYLIC LENS, AND DRIVER DIMMABLE TO 1%. POWDER COAT FINISH.

CEILING, RECESSED

R1 E LED 4000 K 4300 lm 277 V 32 W SAME AS R1 WITH MINMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT OF 900 LM. CEILING, RECESSED

R2 LED 4000 K 3200 lm 277 V 24 W 2' X 2' TROFFER FIXTURE WITH EXTRUDED ALUMINUM HOUSING, HIGH MATTE WHITE REFLECTANCE FINISH, HIGH

OPTICAL GRADE ACRYLIC LENS, AND DRIVER DIMMABLE TO 1%. POWDER COAT FINISH.

CEILING, RECESSED

R2 E LED 4000 K 3200 lm 277 V 24 W SAME AS R2 WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT OF 900 LM. CEILING, RECESSED

RH1 LED 4000 K 26100 lm 277 V 218 W PROVIDE LIGHT FIXTURES AS PART OF CEILING ASSEMBLY, SEE WALKABLE CEILING SPECIFICATION 09 51 01. LIGHT FIXTURES MUST BE DIMMABLE, WITH HINGED REAR ACCESS DOOR, CLEAR TEMPERED GLASS PANEL, COLD ROLLED STEEL PAINT BOOTH LIGHT FIXTURE. FIXTURE MUST BE RATED FOR A CLASS I, DIVISION 2 GROUP C AND D LOCATION.

CEILING, RECESSED

RH1 E LED 4000 K 26100 lm 277 V 218 W SAME AS RH1 WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT 1000 LM. CEILING, RECESSED

S1 E LED 4000 K 9800 lm 277 V 75 W 5" X 4' LINEAR LIGHT FIXTURE, COLD-ROLLED STEEL HOUSING, FROSTED ACRYLIC SHIELDING, 92% MINIMUM AVERAGE REFLECTIVE WHITE POLYESTER POWDER COAT, WHITE FINISH. PROVIDE WITH EMERGENCY BATTERY DRIVER OR EMERGENCY BATTERY INVERTER CAPABLE OF PROVIDING FULL LIGHT OUTPUT OF FIXTURE FOR 90 MINUTES.

WALL, SURFACE

S2 LED 120 V 15 W 4" NOMINAL DIAMETER FLASHING SECURITY BEACON, AMBER COLOR POLYCARBONATE LENS. CEILING, SURFACE

T1 LED 4000 K 6300 lm 277 V 52 W 1' X 4' INDUSTRIAL FIXTURE WITH DIE-FORMED STEEL HOUSING AND 92% MINIMUM AVERAGE REFLECTIVE POWDER

COAT, HEAVY DUTY ENCLOSURE, AND NON-DIMMING DRIVER.

CEILING, SUSPENDED

T1 E LED 4000 K 6300 lm 277 V 52 W SAME AS T1 WITH MINIMUM 90 MINUTE BATTERY BACKUP THAT PROVIDES MINIMUM LUMEN OUTPUT 1200 LM. CEILING, SUSPENDED

T2 E LED 4000 K 6300 lm 277 V 52 W SAME AS T1, PROVIDE WITH EMERGENCY BATTERY DRIVER OR EMERGENCY BATTERY INVERTER CAPABLE OF

PROVIDING 1200 LUMEN OUTPUT FOR 120 MINUTES.

CEILING, SUSPENDED

Y1 E LED 4000 K 2000 lm 277 V 24 W EXTERIOR ARCHITECTURAL WALL PACK, CAST-ALUMINUM HOUSING, ZERO UPLIGHT COMPONENT, BLACK POWDER COAT FINISH, AND ACRYLIC LENS WITH TYPE II DISTRIBUTION AND 90 MINUTE BATTERY BACKUP.

WALL, SURFACE

Y2 LED 4000 K 13600 lm 277 V 120 W EXTERIOR ARCHITECTURAL SITE LIGHT FIXTURE, ZERO UPLIGHT COMPONENT, ONE PIECE DIE-CAST ALUMINUM HOUSING. 1/8" CLEAR ACRYLIC GLASS LENS, IP66 RATING, AND TYPE IV DISTRIBUTION. BLACK POWDER COAT FINISH.

WALL, SURFACE

Y3 LED 4000 K 31800 lm 277 V 240 W EXTERIOR HEAVY DUTY FLOOD LIGHT WITH CAST ALUMINUM HOUSING, AND CLEAR TEMPERED GLASS LENS. IP66 RATING, GLARE SHIELD (FOR SIDE AND UPLIGHT), SPOT STYLE DISTRIBUTION OPTICS, ADJUSTABLE STEEL MOUNTING

HARP. BLACK POWDER COAT FINISH.

WALL, SURFACE

A

M

- 0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

LIGHTING CONTROLS LEGEND

• MANUAL ON/OFF

• OCCUPANCY SENSOR TO TURN LIGHTS ON TO 100% IMMEDIATELY

WHEN MOTION IS SENSED WITHIN SPACE.

• OCCUPANCY SENSOR TO DIM LIGHTS TO 50% WHEN NO MOTION IS

SENSED WITHIN THE SPACE FOR 15 MINUTES AND FULL OFF WHEN NO

MOTION IS SENSED WITHIN THE SPACE FOR 2 HOURS.

• EMERGENCY FIXTURES IN THE SPACE MUST ALWAYS BE ON.

• MANUAL ON/OFF AND DIMMING.

• OCCUPANCY SENSOR TO TURN LIGHTS ON TO 50% IMMEDIATELY WHEN

MOTION IS SENSED WITHIN THE SPACE.

• OCCUPANCY SENSOR TO TURN LIGHTS FULL OFF WHEN NO MOTION IS

SENSED WITHIN THE SPACE FOR 15 MINUTES.

• RECEPTACLE AUTOMATIC CONTROLS MUST BE INSTALLED PER

ASHRAE 90.1-2013, SECTION 8.4.2.

• ALL DUPLEX RECEPTACLES MUST BE CIRCUITED SUCH THAT ONE OF

THE SIMPLEX OUTLETS IS ALWAYS ON (UNCONTROLLED) AND THE

OTHER IS SWITCHED AUTOMATICALLY (CONTROLLED) VIA LOCAL ROOM

OCCUPANCY SENSOR(S).

• THE FOLLOWING RECEPTACLES TYPES IN THESE SPACES TO BE

EXEMPT FROM AUTOMATIC CONTROLS AND WILL BE ON

(UNCONTROLLED) 100% OF THE TIME:

1. REFRIGERATORS (REF)

2. MICROWAVES (MW)

3. COFFEE MAKERS (CB)

4. WALL CLOCKS (WC)

• MANUAL ON/OFF.

• OCCUPANCY SENSOR TO TURN LIGHTS ON TO 50% IMMEDIATELY WHEN

MOTION IS SENSED WITHIN SPACE.

• OCCUPANCY SENSOR TO TURN LIGHTS FULL OFF WHEN NO MOTION IS

SENSED WITHIN THE SPACE FOR 15 MINUTES.

• MANUAL ON/OFF ONLY.

• EMERGENCY LIGHT FIXTURES MUST BE SWITCHED, UON.

• MANUAL ON/OFF AND DIMMING.

• VACANCY SENSOR TO TURN LIGHTS FULL OFF WHEN NO MOTION IS

SENSED WITHIN THE SPACE FOR 15 MINUTES.

• RECEPTACLE AUTOMATIC CONTROLS MUST BE INSTALLED PER

ASHRAE 90.1-2013, SECTION 8.4.2.

• ALL DUPLEX RECEPTACLES MUST BE CIRCUITED SUCH THAT ONE OF

THE SIMPLEX OUTLETS IS ALWAYS ON (UNCONTROLLED) AND THE

OTHER IS SWITCHED AUTOMATICALLY (CONTROLLED) VIA LOCAL ROOM

VACANCY SENSOR(S).

• THE FOLLOWING RECEPTACLE TYPES IN THESE SPACES EXEMPT

FROM AUTOMATIC CONTROLS AND MUST BE ON (UNCONTROLLED)

100% OF THE TIME:

1. REFRIGERATORS (REF)

2. MICROWAVES (MW)

3. COFFEE MAKERS (CB)

4. WALL CLOCKS (WC)

• MANUAL ON/OFF AND DIMMING PER ZONES INDICATED ON PLANS.

• VACANCY SENSOR TO TURN LIGHTS FULL OFF WHEN NO MOTION IS

SENSED WITHIN THE ENTIRE HANGAR BAY FOR 15 MINUTES.

• DAYLIGHT SENSORS TO CONTROL LIGHT FIXTURES AS INDICATED ON

PLANS. DAYLIGHT SENSORS TO ADJUST LIGHT FIXTURE OUTPUT TO

PROVIDE REQUIRED AVERAGE FOOTCANDLES AS INDICATED ON

PLANS.

• EMERGENCY FIXTURES INDICATED ON PLANS MUST ALWAYS BE ON.

• MANUAL ON/OFF SWITCH WITH INTEGRAL TIMER. INTEGRAL TIMER MUST

PROVIDE AUDIBLE AND 'FLASH' WARNING 10 MINUTES PRIOR TO

TURNING OFF LIGHT FIXTURES. AFTER 8 HOURS TIMER MUST

AUTOMATICALLY SHUT OFF LIGHT FIXTURES.

• EMERGENCY FIXTURES IN THE SPACE MUST ALWAYS BE ON.

OS1

OS2-R

OS3

S1

VS1-R

VS1-H

T1

• MANUAL ON/OFF AND DIMMING.

• OCCUPANCY SENSOR TO TURN LIGHTS ON TO 50% IMMEDIATELY WHEN

MOTION IS SENSED WITHIN THE SPACE.

• OCCUPANCY SENSOR TO TURN LIGHTS FULL OFF WHEN NO MOTION IS

SENSED WITHIN THE SPACE FOR 15 MINUTES.

OS2

EM1 • EMERGENCY FIXTURES IN THE SPACE MUST ALWAYS BE ON.

• SPACE DOES NOT CONTAIN LIGHT FIXTURES THAT REQUIRE EXTERNAL

LIGHTING CONTROLS.

N/A

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

W F

-2 -R

-0

EL602

L

IG

H T

IN

G

C O

N T

R O

L S

M A

T R

IX

J M

A J O

R S

Z M

A T

H E

W S

P O

'G O

R M

A N

LIGHTING CONTROLS MATRIX

NAME RM # CONTROLS

PLENUM AREA A&B -- T1

PLENUM AREA C&D -- T1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 1 - A1

-- S1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 1 - A2

-- S1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 1 - B1

-- S1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 1 - B2

-- S1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 2 - C1

-- S1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 2 - C2

-- S1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 2 - D1

-- S1

RETURN PLENUM - ABOVE EXPANDED METAL

PLANK - BAY 2 - D2

-- S1

SUPPLY PLENUM 101 S1

HANGAR BAY 1 102 VS1-H

EXHAUST PLENUM 103A S1

EXHAUST PLENUM 103B S1

VEST 104 EM1

VEST 105 EM1

AIR COMPRESSOR 107 S1

ELEC 108 S1

FOAM ROOM 109 S1

BOILER ROOM 110 S1

SECURE OFFICE 112 VS1-R

SECURE VEST 112A EM1

OFFICE 114 VS1-R

BREAK ROOM 115 OS2-R

LOCKER ROOM 116 OS2

VEST 117 OS1

TRAINING ROOM 118 OS2-R

OFFICE 119 VS1-R

OFFICE 120 VS1-R

MOTHERS ROOM 121 OS2-R

COMM 122 S1

FABRICATION 123 S1

FIRE PUMP 124 S1

TOOL / SUPPORT EQUIP 125 OS3

HAZMAT/ LO STORAGE 126 OS3

DEMIL 127 OS3

VEST 129 EM1

EXHAUST PLENUM 130A S1

EXHAUST PLENUM 130B S1

VEST 131 EM1

HANGAR BAY 2 132 VS1-H

SUPPLY PLENUM 133 S1

STAIR 02 134 EM1

STAIR 01 135 EM1

LO PART STORAGE 136 OS3

SECURE VEST 136A EM1

AIR SHOWER 137 N/A

INITIAL ACCUMULATION POINT 138 OS1

(M) DIRTY 139 OS1

(M) DIRTY SHOWER 140 OS1

(M) CLEAN 141 OS1

(M) CLEAN SHOWER 142 OS1

JAN 143 OS3

(W) CLEAN 144 OS1

(W) CLEAN SHOWER 145 OS1

(W) DIRTY SHOWER 146 OS1

(W) DIRTY 147 OS1

ELEC 148 S1

FIELD TRAINING DETACHMENT 149 OS2-R

SILICONE SANDING ROOM 150 OS3

COMPOSITE SANDING ROOM 151 OS3

SECURE VEST 151A EM1

PAINT BOOTH 153 OS3

CORRIDOR 154 OS1

CORRIDOR 154A EM1

CORRIDOR 154B EM1

CORRIDOR 155 OS1

FOAM ROOM 156 S1

VEST 157 EM1

STORAGE 158 OS3

AHU 159 S1

MECHANICAL 200 S1

STAIR 01 201 EM1

STAIR 02 202 EM1

GENERAL NOTES:

1. SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES,

LEGEND, AND ABBREVIATIONS.

2. SEE SHEET EL501 FOR TYPICAL LIGHTING CONTROL

SCHEMATICS.

3. PREPARE SHOP DRAWINGS INDICATING QUANTITY

AND LOCATIONS OF OCCUPANCY SENSORS PER

MANUFACTURER'S RECOMMENDATION FOR THE

SPACE BEING CONTROLLED.

4. SHOP DRAWINGS TO INCLUDE SCHEMATICS OF THE

PROPOSED LIGHTING CONTROLS FOR EACH TYPE OF

CONTROL SCHEME. SCHEMATICS TO INCLUDE WIRING

DIAGRAMS AND COMPONENT PART NUMBERS.

5. EACH SPACE TO HAVE A DEDICATED LOCAL CONTROL

SCHEME USING STANDARD "OFF THE SHELF"

COMPONENTS. A CENTRAL RELAY/CONTROL PANEL

MUST NOT BE UTILIZED.

6. PROVIDE ALL NECESSARY COMPONENTS REQUIRED

FOR A FULLY FUNCTIONAL SYSTEM PER THE

FEATURES AND FUNCTIONS DESCRIBED FOR EACH

LIGHTING CONTROL SCHEME.

7. LIGHTING CONTROLS TO COMPLY WITH ASHRAE

90.1-2013 AND ASHRAE 189.1.

8. LIGHTING CONTROLS CABLING SHALL BE ROUTED IN

3/4-INCH MINIMUM EMT CONDUIT. ROUTE CONDUIT

CONCEALED OR EXPOSED TO BE CONSISTENT WITH

OTHER CIRCUITS IN THE ROOM.

REQUIRED LIGHTING LEVEL SCHEDULE

NAME RM # MIN. DESIGN FC

WORKPLANE

HEIGHT

PLENUM AREA C&D -- 5 fc 0' - 0"

PLENUM AREA A&B -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 1 - B1 -- 5 fc 0' - 0"

PLENUM - SOUTH DOOR -- 5 fc 0' - 0"

PLENUM - NORTH DOOR -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 2 - D1 -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 2 - C2 -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 1 - A2 -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 1 - A1 -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 1 - B2 -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 2 - C1 -- 5 fc 0' - 0"

RETURN PLENUM - ABOVE EXPANDED METAL PLANK - BAY 2 - D2 -- 5 fc 0' - 0"

SUPPLY PLENUM 101 5 fc 0' - 0"

HANGAR BAY 1 102 125 fc 2' - 6"

EXHAUST PLENUM 103A 5 fc 0' - 0"

EXHAUST PLENUM 103B 5 fc 0' - 0"

VEST 104 5 fc 0' - 0"

VEST 105 5 fc 0' - 0"

AIR COMPRESSOR 107 20 fc 3' - 6"

ELEC 108 20 fc 3' - 6"

FOAM ROOM 109 20 fc 3' - 6"

BOILER ROOM 110 20 fc 3' - 6"

SECURE OFFICE 112 30 fc 0' - 0"

SECURE VEST 112A 30 fc 2' - 6"

OFFICE 114 5 fc 0' - 0"

BREAK ROOM 115 15 fc 2' - 6"

LOCKER ROOM 116 15 fc 0' - 0"

VEST 117 5 fc 0' - 0"

TRAINING ROOM 118 30 fc 2' - 6"

OFFICE 119 30 fc 2' - 6"

OFFICE 120 30 fc 2' - 6"

MOTHERS ROOM 121 15 fc 2' - 6"

COMM 122 50 fc 3' - 0"

FABRICATION 123 50 fc 2' - 6"

FIRE PUMP 124 20 fc 3' - 6"

TOOL / SUPPORT EQUIP 125 20 fc 2' - 6"

HAZMAT/ LO STORAGE 126 20 fc 2' - 6"

DEMIL 127 20 fc 2' - 6"

VEST 129 5 fc 0' - 0"

EXHAUST PLENUM 130A 5 fc 0' - 0"

EXHAUST PLENUM 130B 5 fc 0' - 0"

VEST 131 5 fc 2' - 6"

HANGAR BAY 2 132 125 fc 2' - 6"

SUPPLY PLENUM 133 5 fc 2' - 6"

STAIR 02 134 10 fc 0' - 0"

STAIR 01 135 10 fc 0' - 0"

LO PART STORAGE 136 10 fc 0' - 0"

SECURE VEST 136A 5 fc 0' - 0"

INITIAL ACCUMULATION POINT 138 20 fc 2' - 6"

(M) DIRTY 139 5 fc 0' - 0"

(M) DIRTY SHOWER 140 10 fc 0' - 0"

(M) CLEAN 141 5 fc 0' - 0"

(M) CLEAN SHOWER 142 10 fc 0' - 0"

JAN 143 10 fc 0' - 0"

(W) CLEAN 144 5 fc 0' - 0"

(W) CLEAN SHOWER 145 10 fc 0' - 0"

(W) DIRTY SHOWER 146 10 fc 0' - 0"

(W) DIRTY 147 5 fc 0' - 0"

ELEC 148 20 fc 3' - 6"

FIELD TRAINING DETACHMENT 149 40 fc 2' - 6"

SILICONE SANDING ROOM 150 50 fc 2' - 6"

COMPOSITE SANDING ROOM 151 50 fc 2' - 6"

SECURE VEST 151A 5 fc 2' - 6"

PAINT BOOTH 153 50 fc 2' - 6"

CORRIDOR 154 5 fc 0' - 0"

CORRIDOR 154A 5 fc 0' - 0"

CORRIDOR 154B 5 fc 0' - 0"

CORRIDOR 155 5 fc 0' - 0"

FOAM ROOM 156 20 fc 3' - 6"

VEST 157 5 fc 0' - 0"

STORAGE 158 5 fc 0' - 0"

AHU 159 20 fc 3' - 6"

MECHANICAL 200 20 fc 3' - 6"

STAIR 01 201 10 fc 0' - 0"

STAIR 02 202 10 fc 0' - 0"

A

M

- 0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

J

J

J

J

J

1 2 3 4 5

A

B

C

D

E

F

G

SUPPLY PLENUM

VEST

EXHAUST

PLENUM

103A

HANGAR BAY 1

MATCH LINE

A1/ EP105

M A

T C

H L

IN

E

A

E P

MTS1

HANGAR

BAY 1

DOOR

CONTROL

PANEL

R1-14

EP

R1-31

EP

R1-31

EP

R1-31

EP

MR3-29

GFI

WPIU

MR3-29

GFI

WPIU

MR3-29

GFI

WPIU

R5-22

MR2-26

EP

R5-22

MR2-26

EP

R1-31

EP

MR2-33

EP

MR2-33

EP

FR1-10

EP

FR1-10

EP

CORRIDOR

PLAN

NORTH

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

A B C D

E F

KEY PLAN

NOT TO SCALE

W F

-2 -R

-0

EP101

P O

W E

R P

L A

N

A R

E A

A

M H

A R

A L S

O N

Z M

A T

H E

W S

P O

'G O

R M

A N

SCALE: 1/8" = 1'-0"

A1

POWER PLAN - AREA A

0 4' 8' 16'

GENERAL NOTES:

1. SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES,

LEGEND, AND ABBREVIATIONS.

2. ALL OFFICES, CONFERENCE ROOMS, AND BREAK

ROOMS ARE REQUIRED TO HAVE AUTOMATICALLY

SWITCHED RECEPTACLES PER ASHRAE 90.1. SEE

LIGHTING CONTROL MATRIX ON DRAWING EL602 FOR

SPACES WITH THIS REQUIREMENT.

KEYED NOTES:

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT FOR

CONNECTION TO AIRCRAFT POWER CONVERTER. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP601 FOR

POWER FEED.

PROVIDE 100A STANDARD NEMA 3R RATED "CANNON"

RECEPTACLE FOR PORTABLE GENERATOR PER

UFC-3-540-07 AND UFC-3-540-01.

SEE DETAIL G1 ON SHEET EP501 FOR UTILITY RACK

INFORMATION.

POWER FOR EMERGENCY SHOWER. COORDINATE WITH

FINAL LOCATION OF EMERGENCY SHOWER.

PROVIDE SIMPLEX 20A,120V EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL GFCI CIRCUIT BREAKERS.

MOUNT ALL ELECTRICAL DEVICES IN SPACE AT 48" AFF.

POWER FOR BREATHING AIR ALARM STROBE.

COORDINATE WITH FINAL LOCATION OF STROBE.

POWER FOR FIRE ALARM BEACON. COORDINATE WITH

FINAL LOCATION OF BEACON.

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP602 FOR

POWER FEED.

5 (TYP, UON)

A

M

- 0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

9 4

J

J

J J

J J

6 7 8 9 9.2 10 10.2

A

B

C

D

E

F

G

VEST

LO PART

STORAGE

INITIAL

ACCUMULATION

POINT

EXHAUST

PLENUM

103B

CORRIDOR

154A CORRIDOR

AIR SHOWER

JAN

(M) DIRTY

SHOWER

(M) DIRTY

(W) CLEAN

SHOWER

(W) DIRTY

SHOWER

(W) CLEAN

(M) CLEAN

SHOWER

(M) CLEAN

(W) DIRTY

STAIR 01

SUPPLY PLENUM

HANGAR BAY 1

M A

T C

H L

IN

E

A

E P

M A

T C

H L

IN

E

A

E P

MATCH LINE

A1/ EP105

MATCH LINE

C1/ EP106

R1-14

EPR1-14

EP

R1-29

EP

R1-29

EP

R1-29

EP

R1-29

EP

R2-25

GFI

WPIU

FOAM ROOM

MR3-25

GFI

R5-22

R5-22

MR2-26

EP

R2-26

GFI

AC

R2-2

GFI

R2-26

GFI

AC

R2-26

GFI

AC

R2-26

GFI

AC

R2-2

GFI

R2-2

GFI

R2-2

GFI

R5-4

GFI

R2-27

GFI

R5-7

R2-27

GFI

R2-27

GFI R2-27

GFI

AC

R2-2

GFI

MR2-26

EP

R2-30 R2-30

R2-32 R2-30

R2-30

R2-32

R2-7

GFI

R2-7

GFI

R2-10,12 L6-30R

R2-4

GFI R2-7

GFI

R2-4

GFI

R2-4

GFI

AC

R2-4

GFI

AC

R2-4

GFI

AC

R2-7

GFI

R2-13 L5-30R

R2-7

GFI

R2-7

GFI

AC

P2-14,16,18

R2-24

GFI

R2-24

GFI

R2-24

GFI

R2-5

GFI

R2-5

GFI

R2-9,11 L6-30R

R2-17

GFI

MR2-20

MR2-18

MR2-19

EP

R2-3

FR1-3

EP

MR2-33

EP

MR2-33

EP

FR1-10

EP

MR2-18

SECURE VEST

136A

MR3-37,39,41

EP

CORRIDOR

PLAN

NORTH

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

A B C D

E F

KEY PLAN

NOT TO SCALE

W F

-2 -R

-0

EP102

P O

W E

R P

L A

N

A R

E A

B

M H

A R

A L S

O N

Z M

A T

H E

W S

P O

'G O

R M

A N

SCALE: 1/8" = 1'-0"

A1

POWER PLAN - AREA B

0 4' 8' 16'

GENERAL NOTES:

1. SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES,

LEGEND, AND ABBREVIATIONS.

2. ALL OFFICES, CONFERENCE ROOMS, AND BREAK

ROOMS ARE REQUIRED TO HAVE AUTOMATICALLY

SWITCHED RECEPTACLES PER ASHRAE 90.1. SEE

LIGHTING CONTROL MATRIX ON DRAWING EL602 FOR

SPACES WITH THIS REQUIREMENT.

KEYED NOTES:

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT FOR

CONNECTION TO AIRCRAFT POWER CONVERTER. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP601 FOR

POWER FEED.

MOUNT ALL ELECTRICAL DEVICES IN SPACE AT 48" AFF.

SEE DETAIL G1 ON SHEET EP501 FOR UTILITY RACK

INFORMATION.

POWER FOR EMERGENCY SHOWER. COORDINATE WITH

FINAL LOCATION OF EMERGENCY SHOWER.

POWER FOR AIR SHOWER.

POWER FOR HVAC CONTROLS GRAPHIC USER

INTERFACE. COORDINATE FINAL RECEPTACLE HEIGHT

AND LOCATION WITH HVAC CONTROLS USER INTERFACE

INSTALLATION.

PROVIDE NEMA 5-20R EXPLOSION PROOF RECEPTACLE

WITH GFCI CIRCUIT BREAKERS.

RECEPTACLE FOR LAVATORY POWER ADAPTER.

COORDINATE FINAL RECEPTACLE HEIGHT AND LOCATION

WITH LAVATORY INSTALLATION.

RECEPTACLE FOR PLUG-IN EXHAUST FAN (ABOVE

CEILING). COORDINATE FINAL RECEPTACLE HEIGHT AND

LOCATION ABOVE CEILING WITH EXHAUST FAN

INSTALLATION.

POWER FOR SNOWMELT CONTROL PANEL.

POWER FOR FIRE ALARM AMPLIFIER. COORDINATE WITH

FINAL LOCATION OF FIRE ALARM AMPLIFIER.

POWER FOR BREATHING AIR ALARM STROBE.

COORDINATE WITH FINAL LOCATION OF STROBE.

POWER FOR FIRE ALARM BEACON. COORDINATE WITH

FINAL LOCATION OF BEACON.

PROVIDE 208V/3PH, 60A EXPLOSION PROOF RECEPTACLE

WITH INTEGRAL DISCONNECT.

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP602 FOR

POWER FEED.

7 (TYP, UON)

A

M

- 0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

J

J

J

J

J

J

J

J

J

J

J

J

J

10.2 11 13 14 15 15.2

A

B

C

D

E

F

G

CORRIDOR

154B

STAIR 02

PAINT BOOTH

COMPOSITE

SANDING ROOM

VEST

EXHAUST

PLENUM

130A

SILICONE

SANDING ROOM

ELEC

FIELD TRAINING

DETACHMENT

CORRIDOR

HANGAR BAY 2

SUPPLY PLENUM

CORRIDOR

MATCH LINE

C1/ EP106

M A

T C

H L

IN

E

A

E P

M A

T C

H L

IN

E

A

E P

K1

EP401

R2-22

EP

R2-22

EP

R2-28

EP

R2-28

EP

R2-28

EP

R2-28

EP

R2-25

GFI

WPIU

R2-25

GFI

WPIU

FOAM ROOM

P2-20,22,24

P2-7

R5-41 R5-39

R5-39

MR2-21

EP

MR1-8

R5-37 R5-11

R2-32

R2-19 R2-15

R2-14

R2-29

R2-32

R2-29

R2-29

R2-8

R2-21

FB1

R2-23

FB1

R2-8R2-32 R2-8

R2-8 R5-24

R5-8

R5-24

R2-8

R5-24 R5-14

MR1-8

R2-29

MR1-8

R5-8

MR2-21

EP

R5-8 R5-8

R2-18

P2-15,17,19

R5-41

R5-24

R5-3

R5-1

R5-17 R5-15

R5-37

MR2-20

MR2-20

MR2-16

EP

R2-3

R2-20

FPD

R2-16

R5-11

R5-35

R5-35

FR1-4

EP

MR2-35

EP

MR2-35

EP

MR2-35

FR1-13

EP

SECURE VEST

151A

MR3-31,33,35

EP

R5-27,29 6-30R R5-31,33

6-30R

PLAN

NORTH

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

A B C D

E F

KEY PLAN

NOT TO SCALE

W F

-2 -R

-0

EP103

P O

W E

R P

L A

N

A R

E A

C

M H

A R

A L S

O N

Z M

A T

H E

W S

P O

'G O

R M

A N

SCALE: 1/8" = 1'-0"

A1

POWER PLAN - AREA C

0 4' 8' 16'

GENERAL NOTES:

1. SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES,

LEGEND, AND ABBREVIATIONS.

2. ALL OFFICES, CONFERENCE ROOMS, AND BREAK

ROOMS ARE REQUIRED TO HAVE AUTOMATICALLY

SWITCHED RECEPTACLES PER ASHRAE 90.1. SEE

LIGHTING CONTROL MATRIX ON DRAWING EL602 FOR

SPACES WITH THIS REQUIREMENT.

KEYED NOTES:

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT FOR

CONNECTION TO AIRCRAFT POWER CONVERTER. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP601 FOR

POWER FEED.

MOUNT ALL ELECTRICAL DEVICES IN SPACE AT 48" AFF.

SEE DETAIL G1 ON SHEET EP501 FOR UTILITY RACK

INFORMATION.

POWER FOR EMERGENCY SHOWER. COORDINATE WITH

FINAL LOCATION OF EMERGENCY SHOWER.

POWER FOR AIR SHOWER. COORDINATION

CONNTECTION WITH AIR SHOWER.

PAINT BOOTH INCLUDING ASSOCIATED MAKE-UP AIR

HANDLING UNIT MAU-205, EXHAUST FAN EF-209,

DUCTWORK, PIPE, INSULATION, UTILITY CONNECTIONS,

CONTROLS, AND WIRING SHALL BE A BID OPTION. PAINT

BOOTH, EQUIPMENT AND DUCT SIZES SHOWN ARE

PRELIMINARY. FINAL DESIGN BY PAINT BOOTH

MANUFACTURER AS SPECIFIED IN SECTION 11 50 10 -

PAINT SPRAY BOOTHS. PROVIDE DUCT LEAKAGE (DALT)

FOR PAINT BOOTH EXHAUST AND SUPPLY DUCTWORK.

COORDINATE WITH PAINT BOOTH FOR FINAL LOCATIONS

OF CONNECTIONS.

POWER FOR HVAC CONTROLS GRAPHIC USER

INTERFACE. COORDINATE FINAL HEIGHT AND LOCATION

OF RECEPTACLE WITH HVAC CONTROLS GRAPHIC USER

INSTALLATION.

POWER FOR HVAC STATUS DISPLAY PANEL (LOCATED

ABOVE DOORS). COORDINATE FINAL HEIGHT AND

LOCATION OF RECEPTACLE WITH DISPLAY PANEL

INSTALLATION.

PROVIDE NEMA 5-20R EXPLOSION PROOF RECEPTACLE

WITH GFCI CIRCUIT BREAKERS.

POWER FOR SNOWMELT CONTROL PANEL.

POWER FOR FIRE ALARM AMPLIFIER. COORDINATE WITH

FINAL LOCATION OF FIRE ALARM AMPLIFIER.

POWER FOR BREATHING AIR ALARM STROBE.

COORDINATE WITH FINAL LOCATION OF STROBE.

POWER FOR FIRE ALARM BEACON. COORDINATE WITH

FINAL LOCATION OF BEACON.

POWER FOR SUMP PUMP CONTROL PANEL.

PROVIDE 208V/3PH, 60A EXPLOSION PROOF RECEPTACLE

WITH INTEGRAL DISCONNECT.

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP602 FOR

POWER FEED.

9 (TYP, UON)

A

M

- 0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

16 4

J

J

J J

J

16 17 18 19 20

A

B

C

D

E

F

G EXHAUST

PLENUM

130B

VEST

HANGAR BAY 2

SUPPLY PLENUM

M A

T C

H L

IN

E

A

E P

HANGAR

BAY 2

DOOR

CONTROL

PANEL MTS2

R2-22

EP

R2-31

EP

R2-31

EP

R2-31

EP

R2-31

EP

R2-6

GFI

WPIU

R2-6

GFI

WPIU

R2-6

GFI

WPIU

MR2-21

EP

MR2-21

EP

MR2-2

MR2-35

EP

MR2-35

EP

FR1-13

EP

FR1-13

EP

PLAN

NORTH

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

2 4 6 8 10 12 14 16 18 20

P

M

K

H

F

D

B

W

A R

D P

A R

K W

A Y

K

A N

S A

S C

IT

Y

M

O

A M

A S

H E

K E

L

A F

D R

A W

IN

G

C O

D E

E L L S

W O

R T

H A

IR

F

O R

C E

B A

S E

S

D

P N

F X

B M

F

Y

B -2

L

O W

O B

S E

R V

A B

L E

-B

A Y

R E

S T

O R

A T

IO

N

F A

C

IL

IT

Y

A P

R

IL

A D

V E

R T

IS

E

M E

N T

D E

S

IG

N

A B C D

E F

KEY PLAN

NOT TO SCALE

W F

-2 -R

-0

EP104

P O

W E

R P

L A

N

A R

E A

D

M H

A R

A L S

O N

Z M

A T

H E

W S

P O

'G O

R M

A N

SCALE: 1/8" = 1'-0"

A1

POWER PLAN - AREA D

0 4' 8' 16'

GENERAL NOTES:

1. SEE SHEETS E-001 AND E-002 FOR GENERAL NOTES,

LEGEND, AND ABBREVIATIONS.

2. ALL OFFICES, CONFERENCE ROOMS, AND BREAK

ROOMS ARE REQUIRED TO HAVE AUTOMATICALLY

SWITCHED RECEPTACLES PER ASHRAE 90.1. SEE

LIGHTING CONTROL MATRIX ON DRAWING EL602 FOR

SPACES WITH THIS REQUIREMENT.

KEYED NOTES:

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT FOR

CONNECTION TO AIRCRAFT POWER CONVERTER. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP601 FOR

POWER FEED.

PROVIDE 100A STANDARD NEMA 3R RATED "CANNON"

RECEPTACLE FOR PORTABLE GENERATOR PER

UFC-3-540-07 AND UFC-3-540-01.

SEE DETAIL G1 ON SHEET EP501 FOR UTILITY RACK

INFORMATION.

POWER FOR EMERGENCY SHOWER. COORDINATE WITH

FINAL LOCATION OF EMERGENCY SHOWER.

POWER FOR CONTAINMENT TANK ALARM PANEL.

COORDIANTE WITH FINAL LOCATION OF PANEL.

PROVIDE NEMA 5-20R EXPLOSION PROOF RECEPTACLE

WITH GFCI CIRCUIT BREAKERS.

MOUNT ALL ELECTRICAL DEVICES IN SPACE AT 48" AFF.

POWER FOR BREATHING AIR ALARM STROBE.

COORDINATE WITH FINAL LOCATION OF STROBE.

POWER FOR FIRE ALARM BEACON. COORDINATE WTIH

FINAL LOCATION OF BEACON.

PROVIDE 480V/3PH, 4W, 200A EXPLOSION PROOF

RECEPTACLE WITH INTEGRAL DISCONNECT. SEE

ELECTRICAL ONE-LINE DIAGRAM ON SHEET EP602 FOR

POWER FEED.

6(TYP, UON)

A

M

- 0

D E

S

IG

N I S

S U

E D

F O

R P

R

IC

IN

G

A P

R

A

M E

N D

M E

N T

M A

Y

10 4

J J

J J

J

J

J

J J

J

J

J

J J

JJ

J

3 4 5 6 7 8

J

H

ELEC

BOILER ROOM

LOCKER ROOM

OFFICE

114SECURE VEST

112A

SECURE OFFICE

BREAK ROOM

MATCH LINE

A1/ EP101

M A

T C

H L

IN

E

C

E P

MATCH LINE

A1/ EP102

A1

EP401

MR3-27

GFI

WPIU

MR3-27

GFI

WPIU

J3

EP201

E3

EP201

CR3

MR3-4

MR3-4

CR3-5

CR3-4

CR3-5 CR3-4

MR3-5

MR3-4

MR3-4

MR3-7

M R

-7

MR3-7 R1-28 R1-28

MR3-5

R1-8

+36" AFF

R1-16

+36" AFF

R1-16

+36" AFF

R1-18

+36" AFF

R1-18

+36" AFF

R1-28 R1-28 R1-32

R1-8

+36" AFF

R1-21

+36" AFF

R1-21

+36" AFF

R1-17

+36" AFF

R1-17

+36" AFF

R1-32

AC

R4-20R4-20

R4-20R4-20

R1-32

MR3-5

CR3-2 CR3-2

CR3-2

R1-24

R1-24

R1-24

MR3-5

AHU

AIR

COMPRESSOR

MR3-13

MR3-10

MR3-8

MR3-20

MR3-20

MR3-4

CR3-3

L5-20R

MP6

MR3-3 MR3-3

M R

-1

M R

-1

MR3-2MR3-2

MR3-9

MR3-19 MR3-1

R1-32

AC

R1-22

OH-110B

P1-7,9,11

OH-110C

P1-13,15,17

M M

R1-15

FPD

R1-15

FPD

R1-23

ATS1

D30 D30

M A

T C

H L

IN

E

A

E P

CR3-4

CR3-4

MR3-23

MR3-17

MR3-18

MR3-12

CR3-1

MR3-7

MR3-27

GFI

WPIU

MR1-19,21,23

MR1-14

GENERATOR EG-1 (SEE SHEET

ES402 FOR EXACT LOCATION)

MR3-4

MR3-7

CR3-6,8

L6-30R

R1-13

+36" AFF

R1-13

+36" AFF

R1-25

+36" AFF

R1-25

+36" AFF

MR1-7

EP MR1-7

EP CR3-2CR3-13

MR3-15

MR3-14

C R

-1

C R

-1

C R

-1

C R

-2

C R

-2

C R

-2

PLAN

NORTH

US Army Corps of Engineers ®

SHEET ID

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

N

S A

S C

IT

Y

D

IS

T R

IC

T

E

T

H S

T R

E E

T K

A N

S A

S C

IT

Y

M

O

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

N

3 5 7 9 11 13 15 17 19

L

J

G

E

C

A

D A

T E

M A

R K

D E

S…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .